Académique Documents
Professionnel Documents
Culture Documents
2 0 1 3
Power Conversion Battery Management Circuit Protection Connectors and Insulators Power Distribution Metering Accessories
FA S T D E L I V E R Y QUALITY
WO R L DW I D E AC C E S S TO P RO D U C T I N F O R M AT I O N
I N D U S T RY S TA N DA R D S
www.bluesea.com
Supporting this promise is direct phone technical support access to every Blue Sea Systems manager and engineer to guarantee your satisfaction with our product in your boats electrical system.
C O R P O R AT E O F F I C E
Blue Sea Systems 425 Sequoia Drive Bellingham, WA 98226 USA p 360.738.8230 f 360.734.4195 www.bluesea.com conductor@bluesea.com
F L O R I DA O F F I C E
Blue Sea Systems 4500 140th Avenue N. Suite 117 Clearwater, FL 33762 USA p 727.531.4049 f 727.531.4734
Call 800.222.7617 to reach customer service Monday through Friday, 8am to 5pm Pacific Time. Subscribe to by sending an e-mail to listmaster@bluesea.com
Blue Sea Systems products are designed into systems aboard boats, commercial vehicles, recreational coaches, and for the renewable energy industry.
ISO 9001-2008
Table of Contents
Power Conversion
P-Series Battery Chargers 8-9 P-Series Battery Charger Remote Display 10 DeckHand Dimmers 11
Quick Reference
Batter y Management
Manual Battery Switches Battery Management Panels Remote Battery Switches Automatic Charging Relays 1419 2021 2223 2428 p. 8-9 p. 10 p. 11
INTRODUCTION
Circuit Protection
Fuses Fuse Holders and Blocks Circuit Breakers 3437 3845 4659 p. 15 p. 16 p. 17 p. 2021 p. 22 p. 22, 23, 28 p. 25 p. 26 p. 27
p. 38
p. 38
p. 38
p. 39
p. 40
p. 40
p. 40
p. 41
p. 41
p. 42
p. 43
p. 43
p. 46
p. 47
p. 48
p. 49
p. 50
p. 53
p. 55
p. 5657
Monitoring
Analog Meters and Panels Mounting Panels DIN Meters Digital Meters and Panels Mini Clamp Multimeter Shunts and Current Transformers Vessel Systems Monitor VSM 422 P-Series Amp Hour Meter 2 Inch Round Gauges and Panels 9899 98, 101 100 101102 103 103 104 105 107 p. 6265 p. 65 p. 66 p. 66 p. 67 p. 69
p. 7273
p. 7475
p. 8889
p. 8889
p. 8889
Accessories
360 Panel System Water Resistant Contura Switches WeatherDeck Toggle Switches 12 Volt Socket-plug System Lockout Slides Labels 110111 112 113 115 116 117120 p. 79 p. 82 p. 84 p. 86 p. 90 p. 91 p. 9293 p. 9495
Appendix
DC Discussion Battery Switch Wiring Diagrams Wire and Fuse Selection Chart AC Discussion Marketing Materials Merchandising Plans 121 122123 124126 127 128 129
p. 9899
p. 100
p. 101102
p. 103
p. 103
p. 104105
p. 107
p. 110
p. 110
p. 111
p. 112
p. 113
p. 114
p. 115
p. 117120
NEW PRODUCTS
Power Conversion Battery Management Circuit Protection
INTRODUCTION
3117
Panel enclosure with Dual 120V AC 30A ELCI circuit breakers for boats with two AC shore power sources. Simplifies switching and automates charging for a complete two battery bank solution for trailerable boats.
Power Distribution
360 Panel Modules pages 95, 111
Multi-stage 3 output charger with a rugged cast aluminum case, Selective Float to prevent overcharging and a multi-language full sentence display.
Repeats battery charger display information and includes Amp Hours and SOC for house battery. Easy to install with three mounting options.
Automatically manages the charging current from alternators up to 120 Amps with Auxiliary Battery Priority that shares the alternator charge with the auxiliary battery longer when engine is running.
1479
Integrates a 12V DC Socket and a Dual USB Charger Socket with the 360 Panel System.
Dual 120V AC outlet integrates with 360 Panel System providing easy installation and access for tools and appliances requiring AC power.
Circuit Protection
Monitoring
7518
Monitors Amp Hours for house battery. Calculates amp hours and time remaining with user adjusted alarms to prevent getting stranded with a dead battery.
7504, 7509
Accessories
79297939 page 112
Digitally control dimming of most lights including non-regulated LEDs, with adjustable timed illuminated exit and bulb saver feature.
Battery Management
Combines a range of the most commonly used fuses and amperage ratings in a compact and convenient resealable package.
Dual USB Charger Plug page 115 Mini ACR Automatic Charging Relay page 25
Automatically manages the charging current from alternators up to 65 Amps found on most trailer boats and can be easily surface or panel mounted.
3131
Enclosure offers a surface mount option for mounting single and double pole A-Series Toggle and A and C-Series Flat Rocker circuit breakers.
Easy to use in common 12V sockets found in boats, cars, and recreational vehicles. Dual USB 2.0 Chargers with 2.1 Amps of output for quick charging of popular mobile devices.
DC
9
Blower Horn
DC LOADS
INTRODUCTION
DC
SOURCES
Batter y Management
2.
Compact 300A continuous rated battery disconnect.
6
Running Lights
Circuit Protection
4. ST-Blade Fuse Block (p. 39)
Compact ATO/ATC Fuse Block with independent source to protect both switched and 24-hour circuits.
Cabin Lights
Engine
Connectors, Insulators
5. PowerPost Plus Connector (p. 67)
Enables connection of multiple smaller wires in spaces where a traditional bus bar may not fit.
Switched Circuits
Fish Finder
Power Distribution
6. WeatherDeck Panel (p. 7273)
Blue Sea Systems most waterproof panel for open cockpit or flybridge applications.
Battery 1
GPS
Monitoring
7. DC Digital Multimeter (p. 101)
Splash proof LED monitoring of DC Voltage and Amperage with audio alarms.
VHF
Accessories
NEW 8. Dual USB Chargers (p. 115)
Conveniently charge popular USB-powered mobile devices.
24-Hour Circuits
Battery 2
4
Bilge Pump
LEGEND
Clock
Alarm
This diagram is for reference only. Consult an ABYC certified marine electrical professional for system design.
AC
Shore Power
SOURCES
INTRODUCTION
Power Conversion
NEW 1. P-Series Battery Charger (p. 89)
Digital, multistage charger designed to meet global electrical requirements
NEW 2. P-Series Remote Display (p. 10) 3. DeckHand Dimmer (p. 11)
Digitally controls dimming of non-regulated LEDs, incandescent, and halogen lights
1
Genset
Batter y Management
4. 5.
m-Series Battery Switch (p. 15) Compact 300A continuous rated battery disconnect
e-Series Battery Switch (p. 16) Standard case 350A continuous rated battery disconnect
500A magnetic latching relay with manual control
6. ML-Series Remote Battery Switches (p. 23) 7. SI-ACR Automatic Charging Relay (p. 26)
120A relay automatically manages the charge between two battery banks
Inverter
DC
SOURCES
12
Circuit Protection
9. SMS Surface Mount System (p. 56)
Provides a sealed enclosure for surface mounting ELCI Main and other circuit breakers
4
Engine 1
Engine Battery
Power Distribution
15. WeatherDeck Waterproof Panel (p. 72)
Blue Sea Systems' most waterproof panel for open cockpit or flybridge applications
House Battery
14
Monitoring
17. Vessel Systems Monitor (p. 104105)
Four meters in one including AC, DC with Amp Hours, Tanks and Bilge
7
Auxiliary Battery
This diagram is for reference only. Consult an ABYC certified marine electrical professional for system design.
17
AC
Outlets
AC LOADS
INTRODUCTION
16
15
Microwave
DC
Horn
Refrigerator
DC LOADS
LEGEND
Running Lights
10 13
Cabin Lights
GPS
VHF
Stereo
Windlass
11
Bow Thruster 5
POWER CONVERSION
For over two decades Blue Sea Systems has designed and manufactured products that switch, protect, distribute, and monitor AC and DC systems. Drawing on experience gained from years of design, manufacturing, and customer input, Blue Sea Systems introduces the P-Series Battery Chargers. Customers have asked for a battery charger with the latest technology and features built with the integrity and engineering expertise applied to every Blue Sea Systems product. Customers want a charger that can work anywhere, in any conditions, with any battery type, is easy to install, and intuitive to operate. They also demand a high level of product support for questions and troubleshooting. Blue Sea Systems P-Series Battery Chargers meet these requirements and offer peace of mind with an industry-leading five year warranty.
SECTION INDEX
BATTERY CHARGERS
P-Series Battery Chargers P-Series Battery Charger Remote Display 89 10
DIMMERS
DeckHand Dimmers 11
Blue Sea Systems P-Series Battery Chargers are designed to perform in the most challenging conditions found around the world.
Designed to overcome the three most often reported battery charger problems by offering outstanding:
POWER CONVERSION
Rugged, finned aluminum case and large internal heat sinking dissipates heat for less fan run time and longer component life Universal Line Voltage 90-265V AC 50/60 Hz for use anywhere in the world and compatible with low voltage power sources Field serviceable AC Input power protection to quickly get the vessel back up and running in the event of an AC power surge Selective Float moves each battery individually to float voltage ending absorption period to prevent overcharging
Ease of use
Large, bright display communicates with plain language words Multi-Language: English, Spanish, Italian, French language selection Charge Coordination works with Blue Sea Systems ACRs to properly charge batteries with shore power at the dock or alternator power underway
Support
Blue Sea Systems onboard support and 5 year warranty Extensive suite of diagnostic screens User manual and information updates accessible via QR tag below display
PN
Output 3 3
NEW NEW
7521 7522
Distinguishing Features
AC
ACR Start Start ACR House
Connections
Optional Remote
See page 10
Competitive Sheet metal cross section Competitive Plastic cross section Blue Sea Systems P-Series Battery Charger cast aluminum cross section
Display
AC Power Protection
Field serviceable AC power protection allows fast recovery from AC power surges
Specifications
Part Number Maximum Output Current Nominal Voltage Number of Outputs Maximum Output Voltage Output Voltage Accuracy Minimum AC Input Voltage Maximum AC Input Voltage Min. Operating Temperature Max. Operating Temperature Min. Storage Temperature Max. Storage Temperature Max. Parasitic Current Charger Efficiency Weight lb (kg) 7521 20A 12V DC 3 15.9V DC 0.05V DC 90V AC 265V AC -40C 85C -55C 125C 2mA >80% 6.6 (3.0) 7522 40A 12V DC 3 15.9V DC 0.05V DC 90V AC 265V AC -40C 85C -55C 125C 2mA >80% 8.8 (4.0)
Charge Coordination
A boats batteries typically spend less than 2% of their time being charged by the alternator. For the remaining 98% of the time they are being maintained by the AC battery charger, it is important that the proper charging mode (Bulk, Absorption, Float) is applied to each battery. U N D E RW AY
When engine is running and alternator is charging batteries, ACRs combine batteries, providing charge to all batteries from a single source.
POWER CONVERSION
Regulatory
UL 1236 marine, E marked and CSA C22.2 No. 107.2-01 standards. SAE 1455, Meets ISO 8846 and SAE J1171 external ignition protection requirements, specific NMEA requirements and all elements of the ABYC A-31 standards. Wire terminations and enclosure are compliant to ABYC A-31.
ACR Start Start ACR House
AC
Electrical Performance
Universal line voltage 90-265V AC 50/60 Hz for use anywhere, and is compatible with low voltage power sources Power factor corrected for efficient charging MOSFET output eliminates unintentional voltage differences between batteries providing a faster charge for batteries with the greatest amp-hour deficit AT T H E D O C K
When P-Series Battery Charger is operating, communication with ACRs isolates batteries so the proper Float Charge is applied to all batteries.
AC
ACR Start Start ACR House
Selective Float
40A
14.2V
Battery Voltage
13.5V
BULK
ABSORPTION
POWER CONVERSION
Specifications
Nominal System Voltage Operating Voltage Minimum Current Draw Voltage Accuracy Current Range Current Accuracy
PN
Voltage 12V DC
NEW 7519
Back of 7519
DC Current
1 2 3 4 5 6
Battery Voltage
Battery Battery Temperature
Front Panel
Rear Panel
10
DC
DeckHand Dimmers
Illuminated Exit setting allows boaters to safely disembark before the lights automatically turn off. Using the illuminated exit mode
One minute delay: Hold the switch in up position (bright) for 2 seconds, lights will flash. Release switch after first flash and the lights will remain on for 1 minute.
POWER CONVERSION
Two to five minute delay: Hold the switch in up position (bright) for 1-4 seconds after the first flash. Release the switch after 2 to 5 flashes. The lights will remain on for 1 minute for each flash up to a maximum of 5 minutes.
DIMMER
Down Position For Dim Lamp (blue) Down Input (gray) +V DC (red) Optional Light Switch Fuse
7508
Features
Action: (ON)-OFF-(ON)
Illuminated Exit with adjustable time delay Supports multiple switch locations Memory for last dimmer setting Bulb Saver prevents excessive bulb aging while boats batteries are being charged Offset mounting tabs allow dimmers to be mounted close together Pulse Width Modulation (PWM) maintains constant voltage Retail package includes momentary (ON)-OFF-(ON) switch 8216 (p. 113) See table 9V to 16V See table <2mA -40C to 85C
PN 7506
Weight lb (kg) 0.40 (0.18) 0.40 (0.18) 0.58 (0.26) 0.58 (0.26) 0.64 (0.29)
NEW NEW
Specifications
Vn Nominal Voltage Operating Range Maximum Output Current Maximum Parasitic Current Temperature Rating
Regulatory
E marked Meets ISO 8846 and SAE J1171 external ignition protection requirements
Retail package
2.86" (68.0 mm) 3.23" (82.0 mm)
11
12
BATTERY MANAGEMENT
Battery management is central to safe operation of a boat or vehicle. A battery switch is required by ABYC in every boat with a battery over 800 Cold Cranking Amps (CCA). This requirement exists so the potentially destructive energy in the batteries can be isolated in the event of a fire. With involvement on the American Boating Yacht Council (ABYC) Electrical Component Project Committee, Blue Sea Systems is close to the source of standards for battery switches. The companys participation in the process means quick response when standards and needs of boaters change. In addition to the broadest selection of industry leading manual battery switches, Blue Sea Systems also manufactures a complete offering of Magnetic Latching (ML) Remote Battery Switches and Automatic Charging Relays (ACRs) which provide control of large battery banks with the push of a button from any location aboard the boat. The new Mini Automatic Charging Relay (m-ACR) was developed specifically for boats with outboard propulsion. Limited space, harsh environmental conditions, and alternators which rarely exceed 65A were all considered in the design of the new m-ACR.
SECTION INDEX
MANUAL BATTERY SWITCHES
m-Series
-Series HD-Series Manual Battery Switch Comparison
15 16 17 18-19
SOLENOID SWITCHES
L-Series ML-Series 22 22
Boston Whaler manages three outboards and three battery banks on their 370 Outrage with Blue Sea Systems ML-ACRs and Remote Battery Switches.
13
BATTERY MANAGEMENT
Battery switches isolate the potentially destructive energy in the battery banks when the boat is not in use or during emergencies.
ABYC 11.7.1.2.1: A battery switch shall be installed in the positive conductor(s) from each battery or battery bank with a CCA rating greater than 800 Amperes.
mounting options
Meets American Boat and Yacht
Terminal Studs Tin-plated copper for maximum conductivity and corrosion resistance One-piece design never loosens over time 7/8" (22 mm) length accepts multiple cable terminals
BLANK
BOW THRUSTER
CHASSIS
ENGINE MID
ENGINE PORT
ENGINE STARBOARD
ENGINE
ENGINE 1
ENGINE 2 GENERATOR
HOUSE
PARALLEL
INVERTER
GROUND
WINDLASS
1.298" 32.97mm
Boston Whaler manages batteries on their 285 Conquest Pilothouse with Blue Sea Systems 6011 Mini Dual Circuit Plus Battery Switch.
DC
Dual Circuit
Simultaneously switches two isolated battery banks or circuits. May be used to switch the positive and negative conductors for required applications.
BATTERY MANAGEMENT
Specifications
I10 Cranking Rating: 10 sec. I60 Cranking Rating: 1 min. I300 Intermittent Rating: 5 min. Ic Continuous Rating Vmxo Voltage Max. Operating
Switch set to ON
Regulatory
E marked, ISO 8846,UL Listed - UL 1107 electric power switches Meets American Boat and Yacht Council (ABYC) requirements Meets UL 1500 and SAE J1171 external ignition protection requirements IP66protected against powerful water jets (see inside back cover)
Switch set to ON
Selector 4 Position
Switches isolated battery banks to all loads or combines battery banks to all loads
Switch set to ON 7901 (red), 7901200 (black) Removable Knob Weight: 0.10lb (0.05kg) 7900 (red), 7900200 (black) Removable key Weight: 0.10lb (0.05 kg)
Switch set to 1
9159
Paralleling Link Bus Used to link multiple m-Series Battery Switches together
Two per retail package Weight: 0.14 lb (0.06 kg)
Switch set to 1+2 9159 linking three 6006 ON-OFF m-Series Battery Switches
The positive and negative conductors should not be attached to the same battery switch. The only exceptions are the Dual Circuit Battery Switches, PN 6010 and 5510e. Since these models have electrically isolated circuits and do not include a combine feature, they can provide disconnect to the positive and negative conductors simultaneously.
WARNING
15
Selector 3 Position
Switches isolated battery banks to all loads
Dual Circuit
Simultaneously switches two isolated battery banks or circuits. May be used to switch the positive and negative conductors for required applications.
BATTERY MANAGEMENT
Specifications
I10 I60 I300 Ic Vmxo Cranking Rating: 10 sec. Cranking Rating: 1 min. Intermittent Rating: 5 min. Continuous Rating Voltage Max. Operating
11001*
5510 e
Regulatory
E marked, ISO 8846,UL Listed - UL 1107 electric power switches Meets American Boat and Yacht Council (ABYC) requirements Meets UL 1500 and SAE J1171 external ignition protection requirements IP66protected against powerful water jets (see inside back cover)
Switch set to 2
Selector 4 Position
Switches isolated battery banks to all loads or combines battery banks to all loads
5511e
9001e
shown for reference Please visit bluesea.com to see other battery switch backs
Switch set to 2
* Includes Alternator Field Disconnect (AFD) which protects the diodes in the alternator in the event of the switch being switched to the OFF position while the engine is running. If the AFD is not used to protect the alternator, an LED can be connected to the AFD terminals to indicate when the battery switch is in any position but OFF.
The positive and negative conductors should not be attached to the same battery switch. The only exceptions are the Dual Circuit Battery Switches, PN 6010 and 5510e. Since these models have electrically isolated circuits and do not include a combine feature, they can provide disconnect to the positive and negative conductors simultaneously.
WARNING
16
DC
Selector 4 Position
Switches isolated battery banks to all loads or combines battery banks to all loads
BATTERY MANAGEMENT
Specifications
I10 I60 I300 Ic Vmxo Cranking Rating: 10 sec. Cranking Rating: 1 min. Intermittent Rating: 5 min. Continuous Rating Voltage Max. Operating
3000, 3001*
3002, 3003*
Regulatory
E marked, ISO 8846,UL Listed - UL 1107 electric power switches Meets American Boat and Yacht Council (ABYC) requirements Meets UL 1500 and SAE J1171 external ignition protection requirements IP66protected against powerful water jets (see inside back cover)
Switch set to ON
Selector 3 Position
Switches isolated battery banks to all loads
Switch set to 1
3000
shown for reference Please visit bluesea.com to see other battery switch backs
Switch set to 1
BATTERY
COMMON
ON-OFF
3000 and 3001 Connections
SELECTOR
3002, 3003, and 11003 Connections
Switch set to 2
* Includes Alternator Field Disconnect (AFD) which protects the diodes in the alternator in the event of the switch being switched to the OFF position while the engine is running. If the AFD is not used to protect the alternator, an LED can be connected to the AFD terminals to indicate when the battery switch is in any position but OFF.
17
DC
Selector 3 Position
Switches battery banks to all loads
m-Series
m-Series
e-Series
e-Series
HD-Series
HD-Series
e-Series
HD-Series
PN Battery Inputs Switch Positions Battery Combine Function Alternator Field Disconnect* Make Before Break Contact Design I10 Cranking Rating (10 sec.) I60 Cranking Rating (1 min.) I300 Intermittent Rating (5 min.) Ic Continuous Rating
1 2
6005 1 2
6006 1 2
9003e 1 2 Yes*
9004e 1 2
3000 1 2 Yes*
3001 2 3 Yes* -
11001 2 3 Yes* -
11003
1,500A 775A 500A 300A 48V DC 2.825" (72 mm) 2.825" (72 mm) 2.176" (55 mm) 0.65 lb (0.29 kg) #10 Screw 3/8"-16 (M10) 7/8" (22 mm) 120 in-lb (13.56 N-m) Tin-plated copper 4/0 AWG (120 mm) 1.12" (28.4 mm) UL 1500 SAE J1171 IP66
2,000A 1,000A 600A 350A 48V DC 3.850" (98 mm) 3.850" (98 mm) 3.00" (76 mm) 0.95 lb (0.43 kg) 1/4" (M6) Screw 3/8"-16 (M10) 7/8" (22 mm) 140 in-lb (15.82 N-m) Tin-plated copper 4/0 AWG (120 mm) 1.10" (27.9 mm) UL 1500 SAE J1171 IP66
2,000A 1,000A 600A 350A 48V DC 3.850" (98 mm) 3.850" (98 mm) 3.00" (76 mm) 0.95 lb (0.43 kg) 1/4" (M6) Screw 3/8"-16 (M10) 7/8" (22 mm) 140 in-lb (15.82 N-m) Tin-plated copper 4/0 AWG (120 mm) 1.10" (27.9 mm) UL 1500 SAE J1171 IP66
2,750A 1,325A 900A 600A 32V DC 3.850" (98 mm) 3.850" (98 mm) 3.00" (76 mm) 1.30 lb (0.59 kg) 1/4" (M6) Screw 1/2" (M12) 7/8" (22 mm) 220 in-lb (24.86 N-m) Tin-plated copper 4/0 AWG (120 mm) 1.10" (27.9 mm) UL 1500 SAE J1171 IP66
2,750A 1,325A 900A 600A 32V DC 3.850" (98 mm) 3.850" (98 mm) 3.00" (76 mm) 1.30 lb (0.59 kg) 1/4" (M6) Screw 1/2" (M12) 7/8" (22 mm) 220 in-lb (24.86 N-m) Tin-plated copper 4/0 AWG (120 mm) 1.10" (27.9 mm) UL 1500 SAE J1171 IP66
2,000A 1,000A 600A 350A 32V DC 3.850" (98 mm) 3.850" (98 mm) 3.00" (76 mm) 1.15 lb (0.52 kg) 1/4" (M6) Screw 3/8"-16 (M10) 7/8" (22 mm) 140 in-lb (15.82 N-m) Tin-plated copper 4/0 AWG (120 mm) 1.10" (27.9 mm) UL 1500 SAE J1171 IP66
2,750A 1,150A 700A 500A 32V DC 3.850" (98 mm) 3.850" (98 mm) 3.00" (76 mm) 1.25 lb (0.57 kg) 1/4" (M6) Screw 1/2" (M12) 7/8" (22 mm) 220 in-lb (24.86 N-m) Tin-plated copper 4/0 AWG (120 mm) 1.10" (27.9 mm) UL 1500 SAE J1171 IP66
Vmxo Voltage 48V DC Maximum Operating Width Height Mounting Centers Weight Mounting Terminal Stud Size Terminal Stud Length Maximum Terminal Stud Torque Terminal Stud Material Cable Size to Meet Ratings Cable Clearance for 4/0 Cables Ignition Protected Ingress Protected
2.825" (72 mm) 2.825" (72 mm) 2.176" (55 mm) 0.62 lb (0.28 kg) #10 Screw 3/8"-16 (M10) 7/8" (22 mm) 120 in-lb (13.56 N-m) Tin-plated copper 4/0 AWG (120 mm) 1.12" (28.4 mm) UL 1500 SAE J1171 IP66
* Alternator Field Disconnect (AFD) protects the diodes in the alternator in the event of the switch being switched to the OFF position while the engine is running. If the AFD is not used to protect the alternator, an LED can be connected to the AFD terminals to indicate when the battery switch is in any position but OFF. Reducing cable size will reduce current rating
18
See page 30-31 for Blue Sea Systems' selection of remote battery switches
Selector 4 Position
Switches isolated battery banks to all loads or combines battery banks to all loads
Dual Circuit
Simultaneously switches two isolated battery banks
BATTERY MANAGEMENT
m-Series
e-Series
e-Series
HD-Series
HD-Series
m-Series
e-Series
m-Series
e-Series
6007 2 4 Yes Yes 1,500A 775A 500A 300A 32V DC 2.825" (72 mm) 2.825" (72 mm) 2.176" (55 mm) 0.77 lb (0.35 kg) #10 Screw 3/8"-16 (M10) 7/8" (22 mm) 120 in-lb (13.56 N-m) Tin-plated copper 4/0 AWG (120 mm) 1.12" (28.4 mm) UL 1500 SAE J1171 IP66 2 4 Yes Yes
3003 2 2 -
6010 2 2 -
5511e
2,000A 1,000A 600A 350A 32V DC 3.850" (98 mm) 3.850" (98 mm) 3.00" (76 mm) 1.15 lb (0.52 kg) 1/4" (M6) Screw 3/8"-16 (M10) 7/8" (22 mm) 140 in-lb (15.82 N-m) Tin-plated copper 4/0 AWG (120 mm) 1.10" (27.9 mm) UL 1500 SAE J1171 IP66
2,000A 1,000A 600A 350A 32V DC 3.850" (98 mm) 3.850" (98 mm) 3.00" (76 mm) 1.15 lb (0.52 kg) 1/4" (M6) Screw 3/8"-16 (M10) 7/8" (22 mm) 140 in-lb (15.82 N-m) Tin-plated copper 4/0 AWG (120 mm) 1.10" (27.9 mm) UL 1500 SAE J1171 IP66
2,750A 1,150A 700A 500A 32V DC 3.850" (98 mm) 3.850" (98 mm) 3.00" (76 mm) 1.25 lb (0.57 kg) 1/4" (M6) Screw 1/2" (M12) 7/8" (22 mm) 220 in-lb (24.86 N-m) Tin-plated copper 4/0 AWG (120 mm) 1.10" (27.9 mm) UL 1500 SAE J1171 IP66
2,750A 1,150A 700A 500A 32V DC 3.850" (98 mm) 3.850" (98 mm) 3.00" (76 mm) 1.25 lb (0.57 kg) 1/4" (M6) Screw 1/2" (M12) 7/8" (22 mm) 220 in-lb (24.86 N-m) Tin-plated copper 4/0 AWG (120 mm) 1.10" (27.9 mm) UL 1500 SAE J1171 IP66
1,000A per circuit 650A per circuit 450A per circuit 300A per circuit 32V DC 2.825" (72 mm) 2.825" (72 mm) 2.176" (55 mm) 0.80 lb (0.36 kg) #10 Screw 3/8"-16 (M10) 7/8" (22 mm) 120 in-lb (13.56 N-m) Tin-plated copper 4/0 AWG (120 mm) 1.12" (28.4 mm) UL 1500 SAE J1171 IP66
1,000A per circuit 750A per circuit 525A per circuit 350A per circuit 32V DC 3.850" (98 mm) 3.850" (98 mm) 3.00" (76 mm) 1.16 lb (0.53 kg) 1/4" (M6) Screw 3/8"-16 (M10) 7/8" (22 mm) 140 in-lb (15.82 N-m) Tin-plated copper 4/0 AWG (120 mm) 1.10" (27.9 mm) UL 1500 SAE J1171 IP66
1,000A per circuit 650A per circuit 450A per circuit 300A per circuit 32V DC 2.825" (72 mm) 2.825" (72 mm) 2.176" (55 mm) 0.80 lb (0.36 kg) #10 Screw 3/8"-16 (M10) 7/8" (22 mm) 120 in-lb (13.56 N-m) Tin-plated copper 4/0 AWG (120 mm) 1.12" (28.4 mm) UL 1500 SAE J1171 IP66
1,000A per circuit 750A per circuit 525A per circuit 350A per circuit 32V DC 3.850" (98 mm) 3.850" (98 mm) 3.00" (76 mm) 1.16 lb (0.53 kg) 1/4" (M6) Screw 3/8"-16 (M10) 7/8" (22 mm) 140 in-lb (15.82 N-m) Tin-plated copper 4/0 AWG (120 mm) 1.10" (27.9 mm) UL 1500 SAE J1171 IP66
* Alternator Field Disconnect (AFD) protects the diodes in the alternator in the event of the switch being switched to the OFF position while the engine is running. If the AFD is not used to protect the alternator, an LED can be connected to the AFD terminals to indicate when the battery switch is in any position but OFF. Reducing cable size will reduce current rating
19
DC
BATTERY MANAGEMENT
1408 360 Panel System Backlit circuit labels ON indicating LEDs 3 Unswitched 24-hour circuits 1 C-Series Flat Rocker Circuit Breaker (MAIN 100A) 3 Push Button Reset-Only Circuit Breakers, (BRANCH, 15A) Battery Switch: m-Series, 6011200
Regulatory
Meets UL 1500 and SAE J1171 external ignition protection requirements
8686 Traditional Metal Panel 2 Unswitched 24-hour circuits ON indicating LEDs Spare aperture for additional Flat Rocker or Push Button Reset-Only Circuit Breakers 1 C-Series Flat Rocker Circuit Breaker (MAIN 100A) 2 Push Button Reset-Only Circuit Breakers (BRANCH 15A) Battery Switch: m-Series, 6011 24-hour Round Label Set 4140
1406 360 Panel System 3 Battery Switches: m-Series, 6006200 8690 Traditional Metal Panel 2 Unswitched 24-hour circuits ON indicating LEDs Spare apertures for additional Flat Rocker or Push Button Reset-Only Circuit Breakers 1 C-Series Flat Rocker Circuit Breaker (MAIN 100A) 2 Push Button Reset-Only Circuit Breakers (BRANCH 15A) Battery Switch: e-Series, 5511e 24-hour Round Label Set 4140
1139 (switch not included) 360 Panel System Accepts any m-Series Battery Switch
8080 Traditional Metal Panel 1 C-Series Flat Rocker Circuit Breaker (MAIN 100A) 2 Battery Switches: m-Series, 6006
Vmxo Voltage Max. Operating 48V DC 48V DC 32V DC 12V DC 24V DC 24V DC Width in (mm) 4.88 (123.83) 13.63 (346.08) 6.25 (158.75) 5.25 (133.35) 4.88 (123.83) 4.50 (114.30) 5.25 (133.35) Height in (mm) 4.75 (120.65) 4.75 (120.65) 7.50 (190.50) 6.50 (165.10) 7.75 (196.85) 7.50 (190.50) 8.00 (203.20) Depth in (mm) 0.50 (0.23) 2.50 (63.50) 2.25 (57.15) 3.00 (76.20) 3.50 (88.90) 3.25 (82.55) 3.50 (88.90) Weight lb (kg) 0.50 (0.23) 5.50 (2.50) 3.20 (1.45) 2.20 (1.00) 3.20 (1.45) 1.85 (0.84) 2.64 (1.20)
HOUSE
ACR
START
ENGINE HOUSE
20
DC
BATTERY MANAGEMENT
Regulatory
Meets UL 1500 and SAE J1171 external ignition protection requirements
C-Series Flat Rocker Circuit Breakers (p. 53) Push Button Reset-Only Circuit Breakers (p. 46) Square Format Label Set 4218 included (p. 117) 24-Hour Round Format Label Set 4140 included (p. 117)
PN 1412 8689 8693 Vmxo Voltage Max. Operating 12V DC 24V DC 24V DC Width in (mm) 9.25 (234.95) 7.25 (184.15) 10.50 (266.70) Height in (mm) 7.75 (196.85) 8.00 (203.20) 8.00 (203.20) Depth in (mm) 3.50 (88.90) 3.25 (82.55) 3.50 (88.90) Weight lb (kg) 6.12 (2.78) 3.46 (1.57) 4.42 (2.00)
1412 360 Panel System Backlit circuit labels 4 ON indicating LEDs 8 Unswitched 24-hour circuits 4 A-Series Flat Rocker Circuit Breakers (BRANCH 15A) 8 Push Button Reset-Only Circuit Breakers (BRANCH 15A) 2 Battery Switches: m-Series, 6011200
ACR
HOUSE
START 1
ACR
ENGINE 1 START 2
8689 Traditional Metal Panel 3 Unswitched 24-hour circuits ON indicating LEDs Spare apertures for additional Flat Rocker or Push Button Reset-Only Circuit Breakers 1 C-Series Flat Rocker Circuit Breaker (MAIN 100A) 3 Push Button Reset-Only Circuit Breakers (BRANCH 15A) 2 Battery Switches: m-Series, 6011 24-hour Round Label Set 4140
Blue Sea Systems battery management panels are original equipment aboard the Novurania Chase 31.
8693 Traditional Metal Panel 4 Unswitched 24-hour circuits ON indicating LEDs Spare apertures for additional Flat Rocker or Push Button Reset-Only Circuit Breakers 1 C-Series Flat Rocker Circuit Breaker (MAIN 100A) 4 Push Button Reset-Only Circuit Breakers (BRANCH 15A) 2 Battery Switches: e-Series, 5511e 24-hour Round Label Set 4140
21
DC
BATTERY MANAGEMENT
Features
Hermetically sealed contacts Activated by an ONOFF switch mounted remotely (p. 112-114) Integrated coil control minimizes heating and amperage draw Mount in a dry location 12/24V DC See table See table See table See table 60V DC 1,000,000 Cycles 5 16" (M8) SPST-NO 936V DC 3.80A 0.13A @ 12V DC 0.07A @ 24V DC
7703 (tinned wires)
provided on retail units Deutsch DTM Connector provided on bulk units Other connector plugs are available for high volume OEM applications.
Specifications
Voltage Main Power Contacts I10 Cranking Rating: 10 sec. I60 Cranking Rating: 1 min. I300 Intermittent Rating: 5 min. Ic Continuous Rating Vmxo Voltage Max. Operating Cs Switching Cycles Terminal Stud Size Contact Form Coil Circuit Input Voltage Ioc (inrush, 130ms) Amperage Operating Current Ioc (holding) Amperage Operating Current
Cable End Stripped Wire Deutsch DTM Stripped Wire Deutsch DTM
Weight lb (kg) 1.69 (0.77) 1.69 (0.77) 1.69 (0.77) 1.69 (0.77)
Circuit Function +V DC, 24 Hour Ground -V DC, LED Output +V DC, To Close +V DC, To Open
Features
LED output to remotely indicate switch state - requires optional LED (p. 115) 3 8"-16 tin-plated copper studs for maximum conductivity and corrosion resistance 7 8" (22 mm) stud length accepts multiple cable terminals Label recesses for circuit identification Silver alloy contacts provide high reliability for switching live loads Retail packaging includes Remote Control Contura Switch 2145 (p. 111)
Regulatory
E marked, UL RecognizedUL 508 industrial control equipment Meets SAE J1171 external ignition protection requirements
PN 9012 Voltage 12 / 24V DC Weight lb (kg) 1.00 (0.45)
Specifications
I10 Cranking Rating: 10 sec. I60 Cranking Rating: 1 min. I300 Intermittent Rating: 5 min. Ic Continuous Rating Vmxo Voltage Maximum Operating (control) Cs Switching Cycles Ioc Amperage Operating Current Live Current Switching Terminal Stud Size Terminal Stud Torque Ring Terminal Size Terminal Ring Diameter Clearance See table See table See table See table 16V DC (12 Volt models) 32V DC (24 Volt models) 100,000 Cycles <100 mA when changing state (control circuitmomentary) 300A @ 12V DC10,000 Cycles 3 8"-16 (M10) 140 in-lb (15.5 Nm) See page 28 for 3 8" (M10) dimension drawing 1.18" (30.0 mm)
Regulatory
Blue Sea Systems distinguishes a Solenoid from a Remote Battery Switch to meet E requirements and as guide for best practices. Solenoid- high-amp electronic switch with no manual control, for circuits where a manual battery disconnect is offered elsewhere in the circuit. Remote Battery Switch- a solenoid or relay with a manual control switch allowing for switching if control circuit is compromised and for service lockout. 22
Specifications subject to change. See bluesea.com for current information.
E marked, Meets ISO 8846 and SAE J1171 external ignition protection requirements IP66protected against powerful water jets (see inside back cover)
DC
BATTERY MANAGEMENT
Specifications
I10 Cranking Rating: 10 sec. I60 Cranking Rating: 1 min. I300 Intermittent Rating: 5 min. Ic Continuous Rating Vmxo Voltage Max. Operating Ioc Amperage Operating Current Cs Switching Cycles Terminal Stud Size Terminal Stud Torque Ring Terminal Size Terminal Ring Diameter Clearance
7700, 7700100B 7702, 7702100B See table See table See table See table See table See table 100,000 Cycles 3 8"-16 (M10) 140 in-lb (15.5 Nm) 3 8" (M10) 1.18" (30.0 mm)
7712, 7712100B 7714, 7714100B See table See table See table See table See table See table 100,000 Cycles 3 8"-16 (M10) 140 in-lb (15.5 Nm) 3 8" (M10) 1.18" (30.0 mm)
Deutsch DTM Connector provided on bulk units Other connector plugs are available for high volume OEM applications.
Regulatory
E marked, Meets ISO 8846 and SAE J1171 external ignition protection requirements IP66protected against powerful water jets (see inside back cover)
7700, 7700100B 7702, 7702100B
Wire Color Red Circuit Function +V DC, 24 Hour Ground -V DC LED Output +V DC, To Close +V DC, To Open
Remote Battery Switch PN 7700 7700100B 7702 7702100B 7712 7712100B 7714 7714100B
Coil Volts
ML-Coil Function
Cable End
Voltage Max. Operating 32.0V DC 32.0V DC 32.0V DC 32.0V DC 16.5V DC 16.5V DC 32.0V DC 32.0V DC
Vmxo
Ioc
Ioc
Remote Multi-Station Master Amperage Control Switch Packaged Operating Current Control Switch Switching Control Switch Included Current Capability Capability when Changing State <7A <7A <4A <4A <7A <7A <4A <4A <100 mA <100 mA <100 mA <100 mA <10 mA <10 mA <10 mA <10 mA Yes Yes Yes Yes Yes Yes Yes Yes 2145 SPDT (ON)-OFF-(ON) 2145 SPDT (ON)-OFF-(ON) 2155 SPDT ON-ON* 2155 SPDT ON-ON* Retail Bulk Retail Bulk Retail Bulk Retail Bulk
Ioc
Weight lb (kg)
Bi-Stable Bi-Stable Bi-Stable Bi-Stable Auto Releasing Auto Releasing Auto Releasing Auto Releasing
Stripped Wire Deutsch DTM Stripped Wire Deutsch DTM Stripped Wire Deutsch DTM Stripped Wire Deutsch DTM
1.75 (0.79) 1.75 (0.79) 1.75 (0.79) 1.75 (0.79) 1.75 (0.79) 1.75 (0.79) 1.75 (0.79) 1.75 (0.79)
* Although a SPST switch may be used if desired, use of a SPDT switch improves immunity to inadvertent switching if the control switch becomes damp.
23
ALTERNATOR
There are two main types of charge management devices used on boats:
Automatic Charging Relays (ACR) use a relay combined with a voltage sensing circuit. When a charge is being applied to a battery and the voltage rises over 13V DC, the relay closes and combines the two batteries. When the charge is taken away or the load on the battery is greater than the charging input causing the voltage to drop to 12.75V DC, the relay opens and isolates the two batteries. Battery Isolators are one-way electrical check valves that allow current to flow to, but not from, the battery. Their disadvantage is that they use diodes, which cause a voltage drop that consumes charging energy, creates heat, and causes batteries to be undercharged. Although alternators with external voltage sensing can correct for undercharging, voltage drop and heat remain a problem.
BATTERY 1 BATTERY 2
Battery Isolator
.6V Drop
ALTERNATOR
BATTERY 1
BATTERY 2
1. ACR relay is open and batteries are isolated. Voltage begins to rise slowly after
engine starts or battery charger is turned on.
2. When voltage rises to COMBINE voltage set on ACR 13.5V in this example,
ACR relay closes, connecting and charging both batteries.
3. When engine stops or battery charger is turned off, voltage rapidly begins falling. 4. When voltage falls to 6% less than COMBINE voltage
13.5V less 6% = 12.7V in this example, ACR relay opens, isolating batteries, after 1 minute.
24
Mini ACR
DC
NEW
Mini Add-A-Battery
NEW
Automatically combines batteries during charging, isolates batteries when discharging or at rest
Simplifies switching and automates charging for a complete two battery bank solution for outboard powered boats
BATTERY MANAGEMENT
7601 7649
Features
65 Amp continuous rating manages the charging current from alternators up to 65 Amps found on most outboards and many inboard engines Compact case design allows surface and panel mounting Senses charging on two battery banks Snap-on cover insulates terminal connections LED indicates ACR status 1 4" .032" male quick connect terminal for ground 5 8" (16 mm) stud length to accept multiple cable terminals 12V DC voltage input
m-Series Dual Circuit Plus Battery Switch (p.15) m-Series Dual Circuit Plus Battery Switch simultaneously switches two
isolated battery banks with the option to combine them when start battery is low.
Specifications
I300 Intermittent Rating: 5 min. Ic Continuous Rating Ioc (Combine) Amperage Operating Current Ioc (Open) Amperage Operating Current Maximum Cable Size Terminal Stud Size Maximum Torque Relay Contact Position Combine (30 sec.) (2 min.) Open (10 sec.) (30 sec.) Open High Under Voltage Lockout 115A 65A 175mA 15mA 1/0 AWG 1/4"-20 75 in-lb (8.5 Nm) 13.6V DC 13.0V DC 12.35V DC 12.75V DC 16.0V DC 9.5V DC
ENGINE ON
ACR combines batteries sharing charge with House battery
13.0V or higher
Regulatory
E marked, ISO 8846 Meets UL 1500 and SAE J1171 external ignition protection requirements IP67 - protected against immersion up to 1 meter for 30 minutes
(see inside back cover)
PN 7601 Voltage 12V DC Weight lb (kg) 0.95 (0.43)
1 2
House
Start
ENGINE OFF
ACR isolates batteries protecting the Start battery from discharge
12.4V or lower
House
Start
25
Add-A-Battery
Simplifies switching and automates charging for a complete two battery bank solution
BATTERY MANAGEMENT
Automatically combines batteries during charging, isolates batteries when discharging and when starting engines
7610
Features
120 Amp continuous rating 12/24V DC auto ranging voltage input Senses charging on two battery banks Side and bottom knockouts for cable connections Clip-on cover insulates terminal connections 78" (22 mm) stud length to accept multiple cable terminals Integrated LED indicates ACR status 1 4" .032" male quick connect terminals for ground and optional features
Optional Features
Start Isolation allows temporary isolation of House loads from Engine circuit during engine cranking to protect sensitive electronics from sags and spikes Remote LED remotely indicates ACR states - requires optional LED (p. 115)
Specifications
12V DC I300 Intermittent Rating: 5 min. 210A Ic Continuous Rating 120A Ioc (Combine) Amperage Operating Current 175mA Ioc (Open) Amperage Operating Current 15mA Maximum Cable Size 1/0 AWG Terminal Stud Size 3 8"-16 (M10) Maximum Torque 140 in-lbs Relay Contact Position Combine (30 sec.) 13.6V DC (2 min.) 13.0V DC Open (10 sec.) 12.35V DC (30 sec.) 12.75V DC Over Voltage Lockout 16.0V DC Under Voltage Lockout 9.5V DC
24V DC 210A 120A 115mA 15mA 1/0 AWG 3 8"-16 (M10) 140 in-lbs 27.2V DC 26.0V DC 24.7V DC 25.5V DC 30.0V DC 19V DC
5511e
ENGINE ON
ACR combines batteries sharing charge with House battery
7610
13.0V or higher
Regulatory
E marked, ISO 8846 Meets UL 1500 and SAE J1171 external ignition protection requirements IP67 - protected against immersion up to 1 meter for 30 minutes
(see inside back cover)
House
5511e
Start
ENGINE OFF
ACR isolates batteries protecting the Start battery from discharge
PN 7610
Voltage 12 / 24V DC
7610
12.4V or lower
House
Start
26
DC
Rugged off-road vehicles, including the EarthRoamer, rely on Blue Sea Systems electrical products with the Automatic Charging Relay at the heart of the DC system.
BATTERY MANAGEMENT
7611
Features
120 Amp continuous rating manages the charging current from high output alternators found in many specialty vehicles 12/24V DC auto ranging voltage input Senses charging on two battery banks Side and bottom knockouts for cable connections Clip-on cover insulates terminal connections 78" (22 mm) stud length to accept multiple cable terminals Integrated LED indicates ACR status 1 4" .032" male quick connect terminals for ground and optional connections
Optional Features
Auxiliary Battery Priority shares the alternator charge with the auxiliary battery longer when engine is running Remote LED remotely indicates ACR states - requires optional LED (p. 115)
Specifications
I300 Intermittent Rating: 5 min. Ic Continuous Rating Ioc (Combine) Amperage Operating Current Ioc (Open) Amperage Operating Current Maximum Cable Size Terminal Stud Size Maximum Torque Relay Contact Position Combine (30 sec.) Combine (2 min.) Open Low (30 sec.) Over Voltage Lockout Auxiliary Priority - Optional Feature Open Low (30 sec.)
12V DC 210A 120A 175mA 15mA 1/0 AWG 3 8"-16 (M10) 140 in-lbs 13.6V DC 13.0V DC 12.75V DC 16.0V DC 12.25V DC
24V DC 210A 120A 115mA 15mA 1/0 AWG 3 8"-16 (M10) 140 in-lbs 27.2V DC 26.0V DC 25.5V DC 30.0V DC 24.5V DC
2.56" 65.09mm 4 MOUNTING HOLES FOR #8 OR M4 SCREWS
3.50" 88.96mm
3.89" 98.71mm
1.98" 50.29mm
Regulatory
E marked, ISO 8846 Meets UL 1500 and SAE J1171 external ignition protection requirements IP67 - protected against immersion up to 1 meter for 30 minutes
(see inside back cover)
1.86" 47.12mm
PN 7611
3/8"-16 M10 STUD 0.97" 24.61mm 2.55" 64.77mm 3.31" 84.14mm 0.90" 22.86mm
0.81" 20.45mm
27
DC
BATTERY MANAGEMENT
Deutsch DTM Connector provided on bulk units Other connector plugs are available for high volume OEM applications. Please contact Blue Sea Systems for details.
Wire Color Circuit Function Red Black Remote Ground LED Output SI/EI #1 SI/EI #3 SI/EI #2
Specifications
I10 I60 I300 Ic Cs Ioc Cranking Rating: 10 sec. Cranking Rating: 1 min. Intermittent Rating: 5 min. Continuous Rating Switching Cycles Amperage Operating Current See table See table See table See table 100,000 Cycles <7A when changing state, <40 mA when continuous (control circuitmomentary) 13.5V DC @ 12V 27.0V DC @ 24V 13.0V DC @ 12V 26.0V DC @ 24V 12.35V DC @ 12V 24.7V DC @ 24V 12.75V DC @ 12V 25.5V DC @ 24V 16.2V DC @ 12V 32.4V DC @ 24V 9.6V DC @ 12V 19.2V DC @ 24V 300A @ 12V DC10,000 Cycles 3 8"-16 (M10) 140 in-lb (15.5 Nm) 3 8" (M10) 1.18" (30.0 mm)
2.03" 51.56mm
7620
5.47" 138.94mm 4.50" 114.30mm
Regulatory
E marked, Meets ISO 8846 and SAE J1171 external ignition protection requirements IP67protected against powerful water jets (see inside back cover) Wire Size and Current Ratings
Wire Size 2/0 4/0 2x (4/0) I10 Cranking 10 sec. 2,000A 2,200A 2,500A I60 Cranking 1 min. 750A 750A 1,100A I300 Intermittent 5 min. 400A 400A 700A Ic Continuous (UL 1107) 225A 300A 500A 9160
1.90" 48.26mm
1.03" 26.16mm
Link Bus
Ideal for paralleling ML-Remote Battery Switches and Automatic Charging Relays Tin-plated copper for maximum conductivity and corrosion resistance 500A continuous rating Sold individually Weight: 0.2 lb (0.09 kg)
Coil Volts 12V DC 12V DC 12V DC 12V DC 24V DC 24V DC 24V DC 24V DC
Cable End Stripped Wire Deutsch DTM Stripped Wire Deutsch DTM Stripped Wire Deutsch DTM Stripped Wire Deutsch DTM
Weight lb (kg) 1.69 (0.77) 1.69 (0.77) 1.75 (0.79) 1.75 (0.79) 1.69 (0.77) 1.69 (0.77) 1.75 (0.79) 1.75 (0.79)
28
1 Select an ACR that has a CONTINUOUS rating 2 Review the PRESET ACR SETTINGS 3 Select the ACR with the desired
PRODUCT FEATURES
See page 24 for an explanation.
above the maximum alternator output rating and an INTERMITTENT rating that is above the largest load on the auxiliary battery.
Part Number 7601 7611 7610 7620 7622
BATTERY MANAGEMENT
Step Step
CONTINUOUS INTERMITTENT
65A 115A
120A 210A
120A 210A
500A 700A
500A 700A
ACR
for 30 sec.
for 30 sec.
13.6V
Start
Auxiliary
Open Voltage
No charge present or loads exceed charge input Voltage in either battery is 12.75V for 30 sec. Relay will open isolating batteries Isolated batteries do not share charge
12.75V
ACR
for 30 sec.
12.75V
for 30 sec.
Start
Auxiliary
for 30 sec.
13.6V Start
for 30 sec.
9.6V
Auxiliary
PRODUCT FEATURES
Auxiliary Battery Priority
Condition: Engine running - Open voltage is lowered to 12.25V from 12.75V - Relay remains closed longer, combining batteries, to allow use of auxiliary loads for a longer period of time
ACR
>12.25V
for 30 sec.
>12.25V
for 30 sec.
Start
Auxiliary
Start Isolation
Condition: Engine starting - Relay is open isolating batteries - Batteries are isolated to protect sensitive electronics from voltage sags and spikes
ACR
Start Auxiliary
Start Assist
Condition: Engine starting (Press Contura Switch) - Relay is closed combining batteries - Batteries are combined to share power in the event of a low start battery
ACR
Start Auxiliary
Engine Isolation
Condition: Two engines are running - One relay is open and one relay is closed - Engine 1 Start and Engine 2 Start batteries are isolated to protect engine electronics - If requested by engine manufacturer
ACR
Eng. 1 Start Auxiliary
ACR
Eng. 2 Start
Manual Override
Manual override knob provides an added level of safely allowing manual control of functions
29
DC
Solenoid Switches
Provides high-amp switching
L-Series ML-Series ML-Series
PN Manual Control Nominal Voltage I10 Cranking Rating (10 sec.) I60 Cranking Rating (1 min.) I300 Intermittent Rating (5 min.) Ic Continuous Rating Amperage Operating Current - continuous Amperage Operating Current - when changing state Switching Cycles Coil Function Control Switch Included Control Circuit Connection Mounting Terminal Stud Size Terminal Stud Length Maximum Terminal Stud Torque Cable Size to Meet Ratings Terminal Ring Diameter Clearance Width Height Depth Weight Ignition Protected Ingress Protected
(see inside back cover)
9012
12/24V DC 1,500A DC 850A DC 600A DC 450A DC 0.13A @ 12V DC 0.07A @ 24V DC 3.8A DC 1,000,000 Normally Open Tinned Wire #10 Screw 5/16" (M8) 5/8" (15.87 mm) 80 in-lb (9.0 Nm) 2/0 AWG x 2 not rated 3.17" (80.50 mm) 2.63" (66.80 mm) 2.86" (72.64 mm) 1.00 lb (0.45 kg) SAE J1171
7701*
7703*
Yes
7700*
Yes
7702*
Yes
7712*
Yes
7714*
12V DC 2,500A DC 1,100A DC 700A DC 500A DC 0mA < 7.0A DC 100,000 ML Bi-Stable 2145 SPDT (ON)-OFF-(ON) Tinned Wire #10 Screw 3/8"-16 (M10) 7/8" (22 mm) 140 in-lb (15.5 Nm) 4/0 AWG x 2 1.12" (28.4 mm) 3.75" (95.2 mm) 5.47" (138.9 mm) 2.03" (51.6 mm) 1.69 lb (0.77 kg) ISO 8846 SAE J1171 IP66
24V DC 2,500A DC 1,100A DC 700A DC 500A DC 0mA < 4.0A DC 100,000 ML Bi-Stable 2145 SPDT (ON)-OFF-(ON) Tinned Wire #10 Screw 3/8"-16 (M10) 7/8" (22 mm) 140 in-lb (15.5 Nm) 4/0 AWG x 2 1.12" (28.4 mm) 3.75" (95.2 mm) 5.47" (138.9 mm) 2.03" (51.6 mm) 1.69 lb (0.77 kg) ISO 8846 SAE J1171 IP66
12V DC 2,500A DC 1,100A DC 700A DC 500A DC 0mA < 7.0A DC 100,000 ML Bi-Stable 2145 SPDT (ON)-OFF-(ON) Tinned Wire #10 Screw 3/8"-16 (M10) 7/8" (22 mm) 140 in-lb (15.5 Nm) 4/0 AWG x 2 1.12" (28.4 mm) 3.75" (95.2 mm) 5.47" (138.9 mm) 2.03" (51.6 mm) 1.75 lb (0.79 kg) ISO 8846 SAE J1171 IP66
24V DC 2,500A DC 1,100A DC 700A DC 500A DC 0mA < 4.0A DC 100,000 ML Bi-Stable 2145 SPDT (ON)-OFF-(ON) Tinned Wire #10 Screw 3/8"-16 (M10) 7/8" (22 mm) 140 in-lb (15.5 Nm) 4/0 AWG x 2 1.12" (28.4 mm) 3.75" (95.2 mm) 5.47" (138.9 mm) 2.03" (51.6 mm) 1.75 lb (0.79 kg) ISO 8846 SAE J1171 IP66
12V DC 2,500A DC 1,100A DC 700A DC 500A DC < 13mA < 7.0A DC 100,000 ML Auto-Releasing 2155 SPDT ON-ON Tinned Wire #10 Screw 3/8"-16 (M10) 7/8" (22 mm) 140 in-lb (15.5 Nm) 4/0 AWG x 2 1.12" (28.4 mm) 3.75" (95.2 mm) 5.47" (138.9 mm) 2.03" (51.6 mm) 1.75 lb (0.79 kg) ISO 8846 SAE J1171 IP66
24V DC 2,500A DC 1,100A DC 700A DC 500A DC < 13mA < 4.0A DC 100,000 ML Auto-Releasing 2155 SPDT ON-ON Tinned Wire #10 Screw 3/8"-16 (M10) 7/8" (22 mm) 140 in-lb (15.5 Nm) 4/0 AWG x 2 1.12" (28.4 mm) 3.75" (95.2 mm) 5.47" (138.9 mm) 2.03" (51.6 mm) 1.75 lb (0.79 kg) ISO 8846 SAE J1171 IP66
* Bulk units available that incorporate Deutsch DTM Connectors. Other connector plugs are available for high volume OEM applications.
30
Go to pages 18-19 for Blue Sea Systems selection of manual battery switches
SafetyHub 250
SafetyHub 250 Fuse Block with Remote Battery Switch
Combines remote switching with Allows charging of multiple batteries from a single charge source circuit protection
SI-Series ML-Series ML-Series ML-Series ML-Series
7601
7611
7610
7620*
Yes
7622*
7621*
Yes
7623*
12V DC N/A N/A 115A DC 65A DC Normally Open #10 or M5 1/4"-20 5/8" (16 mm) 75 in-lb (8.5 Nm) 8 AWG 1.12" (28.4 mm) 2.84" (72.14 mm) 2.84" (72.14 mm) 2.57" (65.21 mm) 0.7lb (0.32 kg) ISO 8846, UL1500 SAE J1171 IP67
12/24V DC N/A N/A 210A DC 120A DC 15mA open 175mA combined Normally Open #8 or M4 3/8"-16 (M10) 1.5" (38.1 mm) 140 in-lb (15.5 Nm) 1/0 AWG 1.12" (28.4 mm) 3.89" (99 mm) 3.50" (89 mm) 1.98" (50.30 mm) 1.26 lb (0.57 kg) ISO 8846, UL1500 SAE J1171 IP67
12/24V DC N/A N/A 210A DC 120A DC 15mA open 175mA combined Normally Open #8 or M4 3/8"-16 (M10) 1.5" (38.1 mm) 140 in-lb (15.5 Nm) 1/0 AWG 1.12" (28.4 mm) 3.89" (99 mm) 3.50" (89 mm) 1.98" (50.30 mm) 1.26 lb (0.57 kg) ISO 8846, UL1500 SAE J1171 IP67
12V DC 2,500A DC 1,100A DC 700A DC 500A DC < 40mA < 7.0A DC 100,000 ML Bi-Stable 2146 SPDT ON-OFF-ON Tinned Wire #10 Screw 3/8"-16 (M10) 7/8" (22 mm) 140 in-lb (15.5 Nm) 4/0 AWG x 2 1.12" (28.4 mm) 3.75" (95.2 mm) 5.47" (138.9 mm) 2.03" (51.6 mm) 1.69 lb (0.77 kg) ISO 8846 SAE J1171 IP66
12V DC 2,500A DC 1,100A DC 700A DC 500A DC < 40mA < 7.0A DC 100,000 ML Bi-Stable 2146 SPDT ON-OFF-ON Tinned Wire #10 Screw 3/8"-16 (M10) 7/8" (22 mm) 140 in-lb (15.5 Nm) 4/0 AWG x 2 1.12" (28.4 mm) 3.75" (95.2 mm) 5.47" (138.9 mm) 2.03" (51.6 mm) 1.75 lb (0.79 kg) ISO 8846 SAE J1171 IP66
24V DC 2,500A DC 1,100A DC 700A DC 500A DC < 40mA < 4.0A DC 100,000 ML Bi-Stable 2146 SPDT ON-OFF-ON Tinned Wire #10 Screw 3/8"-16 (M10) 7/8" (22 mm) 140 in-lb (15.5 Nm) 4/0 AWG x 2 1.12" (28.4 mm) 3.75" (95.2 mm) 5.47" (138.9 mm) 2.03" (51.6 mm) 1.69 lb (0.77 kg) ISO 8846 SAE J1171 IP66
24V DC 2,500A DC 1,100A DC 700A DC 500A DC < 40mA < 4.0A DC 100,000 ML Bi-Stable 2146 SPDT ON-OFF-ON Tinned Wire #10 Screw 3/8"-16 (M10) 7/8" (22 mm) 140 in-lb (15.5 Nm) 4/0 AWG x 2 1.12" (28.4 mm) 3.75" (95.2 mm) 5.47" (138.9 mm) 2.03" (51.6 mm) 1.75 lb (0.79 kg) ISO 8846 SAE J1171 IP66
31
32
CIRCUIT PROTECTION
Best practices and ABYC standards state that every positive wire on the boat outside the engine starting circuit must have circuit protection. When excessive current flows in an electrical circuit, wire insulation can melt and possibly start a fire. Circuit breakers and fuses protect the wire in electrical circuits. Blue Sea Systems extensive selection of circuit breakers, fuses, fuse holders, and fuse blocks gives boaters a range of choices for main and branch circuit protection. To help select the right size wire and proper fuse or circuit breaker, Blue Sea Systems offers several tools: a web application found at www.circuitwizard.bluesea.com, a Mobile Application for iPhone and Android devices, You Can Do It Guides, and a step-by-step guide on pages 124126 of this catalog. The demand for ignition protected circuit protection has increased. Blue Sea Systems Safety and SafetyHub Fuse Blocks are specifically designed for use in environments with explosive fumes, such as an engine room or fuel storage locker.
SECTION INDEX
FUSES and FUSE HOLDERS
GMA and AGA Fuses AGC and MDL Fuses ATO or ATC Fuses MAXI Fuses MEGA OR AMG Fuses AMI or MIDI Fuses Terminal Fuses (MRBF) Class T Fuses ANL Fuses AGC or MDL In-Line Fuse Holders ATO or ATC In-Line Fuse Holders 34 34 35 35 36 36 36 37 37 38 38 38 38 39 40 40 40 41 41 42 43 43 4445 46 47 48 49 50 51 52 53 5657 5859
FUSE BLOCKS
ST Glass Fuse Blocks MAXI Fuse Block ST Blade Fuse Blocks Terminal Fuse Blocks (MRBF) MIDI or AMI Safety Fuse Block MEGA or AMG Safety Fuse Block ANL Fuse Blocks Class T Fuse Block
CIRCUIT BREAKERS
Push Button Reset-Only Mounting Panel and Waterproof Boots Medium Duty Push Button Reset-Only and Mounting Panel 285-Series and Mounting System 187-Series A-Series Toggle and Mounting Panels A-Series Rocker C-Series Toggle and Mounting Panels C-Series Rocker
Blue Sea Systems ST-Blade Fuse Block distributes and protects multiple loads on the Grady White Canyon 271.
Residual Current Circuit Breakers (ELCI and GFCI) 55 SMS Surface Mount System Circuit Breaker Comparison
33
AC
DC
Color coding system matches fuses with the corresponding holder or block for easier component selection. Look for color rectangles on the packaging of each fuse holder and block, match the color with the fuse packaging to find the correct fuse type. Some fuse blocks, such as the SafetyHub 150, require two different fuse types. Both color areas are shown on the SafetyHub packaging.
GMA Fuse
Specifications
Iic Interrupting Capacity Vmxo Voltage Max. Operating Itr Amperage Trip Reference Blow Time Delay GMA Dimensions AGA Dimensions
PN 5280 5281 5282 5283 5284 5285 5275 Fuse Type GMA GMA GMA GMA GMA GMA AGA Itr Amps 1A 2A 3A 5A 7A 10A 20A
See www.bluesea.com See table See table See www.bluesea.com 5 mm (0.196") x 20 mm (0.79") 0.25" (6.35 mm) x 0.625" (15.87 mm)
Vmxo DC Volts 24V DC 24V DC 24V DC 24V DC 24V DC 24V DC 32V DC Vmxo AC Volts 250V AC 250V AC 250V AC 125V AC 125V AC 125V AC Weight lb (kg) 0.1 (0.04) 0.1 (0.04) 0.1 (0.04) 0.1 (0.04) 0.1 (0.04) 0.1 (0.04) 0.1 (0.04)
SafetyHub 150 Fuse Block package shows blue (ATO or ATC) and black (AMI or MIDI) rectangles to represent fuse types required
The color rectangles represent the fuses available through Blue Sea Systems, and are color coded on the packaging:
Specifications
Vmxo Voltage Max. Operating Itr Amperage Trip Reference Blow Time Delay Dimensions
See page 38 for ST-Glass Fuse Blocks
32V DC / See table for AC See table See www.bluesea.com 0.25" (6.30 mm) x 1.25" (32.00 mm)
AGC Fuses
PN 5201 5202 5204 5205 Itr Amps Vmxo Volts Weight lb (kg) .25A .5A 1A 1.5A 2A 2.5A 3A 4A 5A 6A 7A 7.5A 10A 15A 20A 25A 30A 250V AC 250V AC 250V AC 250V AC 250V AC 250V AC 250V AC 250V AC 250V AC 250V AC 250V AC 250V AC 250V AC 0.1 (0.04) 0.1 (0.04) 0.1 (0.04) 0.1 (0.04) 0.1 (0.04) 0.1 (0.04) 0.1 (0.04) 0.1 (0.04) 0.1 (0.04) 0.1 (0.04) 0.1 (0.04) 0.1 (0.04) 0.1 (0.04) 0.1 (0.04) 0.1 (0.04) 0.1 (0.04) 0.1 (0.04)
MDL Fuses
PN 5226 5227 5228 5229 5230 5231 5232 5233 5234 Itr Amps 3A 5A 6.25A 7.5A 10A 15A 20A 25A 30A Vmxo Volts Weight lb (kg) 250V AC 250V AC 250V AC 250V AC 0.1 (0.04) 0.1 (0.04) 0.1 (0.04) 0.1 (0.04) 0.1 (0.04) 0.1 (0.04) 0.1 (0.04) 0.1 (0.04) 0.1 (0.04)
Replacement fuses
5206 5207 5208 5209 5210 5211 5212 5213 5215 5217 5218 5219 5220
34
DC
Fuse Kits
Combines a range of the most commonly used fuses and Amp ratings in a compact and convenient resealable package
NEW Fast-acting glass fuse ideal for small electronic devices
CIRCUIT PROTECTION
Features
Tin-plated connector blades for corrosion resistance Visible indication of blown condition Two per retail package
PN 5235 5236 5237 5238 5239 5240 5241 5242 5243 5244 5245
Specifications
Iic Interrupting Capacity Vmxo Voltage Max. Operating Itr Amperage Trip Reference Blow Time Delay Weight per package 1,000A 32V DC See table See www.bluesea.com 0.03 lb (0.01kg)
See page 39 for ST-Blade Fuse Blocks See page 73 for WeatherDeck Waterproof Fuse Panels
ATM Fuses
Mini blade-type fuse Features
Color-coded for easy amperage identification Two per retail package 5289 Includes 40 AGC fuses and a Heavy Duty In-Line Fuse Holder 5063 (p. 38)
PN Fuse Itr Amps Included 1A, 3A, 5A,10A,15A 4 each 1A, 2A, 3A, 5A, 7.5A, 10A, 15, 20A, 25A, 30A
Specifications
Iic Interrupting Capacity Vmxo Voltage Max. Operating Itr Amperage Trip Reference Blow Time Delay
PN 5270 5271 5272 5273 5274 Itr Amps 5A 10A 15A 20A 30A
5288 5289
Weight lb (kg) 0.1 (0.04) 0.1 (0.04) 0.1 (0.04) 0.1 (0.04) 0.1 (0.04)
NEW
0.295" 7.50mm
MAXI Fuses
Provides economical branch circuit protection
1.155" 29.34mm 0.355" 8.9mm 1.360" 34.54mm
0.860" 21.84mm
NEW
Features
Silver-plated connector blades for corrosion resistance Visible indication of blown condition One per retail package
Specifications
Iic Interrupting Capacity Vmxo Voltage Max. Operating Itr Amperage Trip Reference Blow Time Delay Weight per package 1,000A 32V DC See table See www.bluesea.com 0.04 lb (0.02 kg)
35
DC
Terminal Fuses
CIRCUIT PROTECTION
Features
Clear window offers visible indication of blown condition Color-coded for easy amperage identification Two per retail package
Specifications
Iic Interrupting Capacity Vmxo Voltage Max. Operating Itr Amperage Trip Reference Weight per package 5,000A @ 16V DC | 2,000A @ 32V DC 32V DC See table below 0.1lb (0.04kg)
Features
High Interrupt Rating satisfies ABYC requirements for DC Main circuit protection on large battery banks Clear windowvisual indication of blown condition Color-coded for easy amperage identification One per retail package
Specifications
Iic Interrupting Capacity 10,000A @ 14V DC 5,000A @ 32V DC 2,000A @ 58V DC 58V DC See table below M8 (516") See www.bluesea.com
PN 5250 5251 5252 5253 5254 5255 5256 5257 5258 5259 5260
Weight lb (kg) 0.1 (0.04) 0.1 (0.04) 0.1 (0.04) 0.1 (0.04) 0.1 (0.04) 0.1 (0.04) 0.1 (0.04) 0.1 (0.04) 0.1 (0.04) 0.1 (0.04) 0.1 (0.04)
0.329" 8.36mm 0.480" 12.19mm
0.22" 5.5mm
Vmxo Voltage Max. Operating Itr Amperage Trip Reference Fuse Hole Opening Trip Time Delay
Regulatory
Meets SAE J1171 external ignition protection requirements IP66protected against powerful water jets (see inside back cover)
ABYC E-11.12.1.1.1. Each ungrounded conductor connected to a battery charger, alternator, or other charging source, shall be provided with over current protection within a distance of seven inches (175mm) of the point of connection to the DC electrical system or to the battery. See page 40 for MRBF Terminal Fuse Blocks (Marine Rated Battery Fuse) 2151 and 5191
PN
Specifications
Itr Amps 30A 40A 50A 60A 75A 80A 90A 100A 125A 150A 175A 200A 225A 250A 300A
Color LT Green LT Blue Red Gold Brown Lime Purple Yellow Green Orange White Blue Tan Pink Gray
Weight lb (kg) 0.06 (0.03) 0.06 (0.03) 0.06 (0.03) 0.06 (0.03) 0.06 (0.03) 0.06 (0.03) 0.06 (0.03) 0.06 (0.03) 0.06 (0.03) 0.06 (0.03) 0.06 (0.03) 0.06 (0.03) 0.06 (0.03) 0.06 (0.03) 0.06 (0.03)
Iic Interrupting Capacity Vmxo Voltage Max. Operating Itr Amperage Trip Reference Trip Time Delay
5175 5176 5177 5178 5180 5181 5182 5183 5184 5185 Weight lb (kg) 0.06 (0.03) 0.06 (0.03) 0.06 (0.03) 0.06 (0.03) 0.06 (0.03) 0.06 (0.03) 0.06 (0.03) 0.06 (0.03) 5186 5187 5188 5189 5190
See page 125 to choose the correct fuse and fuse amperage.
36
DC
Class T Fuses
Use with Class T Fuse Blocks for circuit protection of devices including inverters. High interrupt capacity for large battery banks including Lithium-Ion and TPPL batteries
ANL Fuses
Use with ANL Fuse Blocks for many applications with 35750 Amp loads
CIRCUIT PROTECTION
Features Features
20,000 Amp Interrupt Rating Extremely fast short-circuit response Recommended by most inverter manufacturers One per retail package 20,000A @ 160V DC 160 Volts DC See table below See www.bluesea.com 6,000 Amp Interrupt Rating satisfies ABYC requirements for main DC circuit protection on large battery banks Silver-plated connector blades for corrosion resistance Visible indication of blown fuse condition One per retail package
Specifications
Iic Interrupting Capacity Vmxo Voltage Maximum Operating Itr Amperage Trip Reference Trip Time Delay 6,000A @ 32V DC 32 Volts DC See table below See www.bluesea.com
Specifications
Iic Interrupting Capacity Vmxo Voltage Max. Operating Itr Amperage Trip Reference Trip Time Delay
Regulatory
35-500A ONLYMeets ISO 8846 and SAE J1171 external ignition protection requirements
See page 41 for the ANL Fuse Blocks 5503, 5004, and 5005
ACCEPTS 5/16" [M8] BOLT
Regulatory
1.450" 36.83mm
0.860" 21.84mm
0.750" 19.05mm
1.000" 25.40mm
PN 5164
Itr Amps 35A 40A 50A 60A 80A 100A 130A 150A 175A 200A 225A 250A 275A 300A 325A 350A 400A 500A 600A 675A 750A
Weight lb (kg) 0.05 (0.02) 0.05 (0.02) 0.05 (0.02) 0.05 (0.02) 0.05 (0.02) 0.05 (0.02) 0.05 (0.02) 0.06 (0.03) 0.06 (0.03) 0.06 (0.03) 0.06 (0.03) 0.07 (0.04) 0.07 (0.04) 0.07 (0.04) 0.07 (0.04) 0.07 (0.04) 0.08 (0.04) 0.08 (0.04) 0.08 (0.04) 0.08 (0.04) 0.08 (0.04)
Weight lb (kg) 0.30 (0.14) 0.30 (0.14) 0.30 (0.14) 0.30 (0.14) 0.30 (0.14)
5165 5122 5123 5124 5125 5126 5127 5128 5129 5130 5131 5132 5133 5134 5135 5136 5137 5161 5162 5163
See page 44 to see the Fuse and Fuse Holder Comparison. Specifications subject to change. See bluesea.com for current information.
37
DC
CIRCUIT PROTECTION
5060
Accepts 12-16 AWG wire 30A Max. fuse amperage Fuse sold separately (p. 34) Weight: 0.1lb (0.04kg)
5061
For use with AGC or MDL glass fuses Accepts 12-16 AWG wire 30A Max. fuse amperage Fuse sold separately (p. 34) Weight: 0.1 lb (0.04 kg)
5062
3.500" 88.90mm
5062
For use with AGC or MDL glass fuses Supplied with 12 AWG pigtails 20A Max. fuse amperage Fuse sold separately (p. 34) Weight: 0.1 lb (0.04 kg)
5015
Features
Can be used for 24-hour circuits Integrated fuse ejector levers Clear insulating cover satisfies ABYC/USCG insulation requirements, accepts large format labels (p. 117), and provides storage for spare fuses Tin-plated phosphor bronze fuse clips are encapsulated and cannot be sprung Removable positive bus for consolidation of in-line fuses Fuses sold separately (p. 34)
5063
For use with AGC or MDL glass fuses Supplied with tinned copper 12 AWG pigtails 30A Max. fuse amperage Fuse sold separately (p. 34) Weight: 0.1 lb (0.04 kg)
Specifications
Vmxo Voltage Max. Operating Imxo Amperage Max. Operating Imxo Amperage Max. Operating Fuse Type Screw Terminal Mounting
PN 5015 5018 Circuits 6 6
5021
5022
For use with AGC or MDL glass fuses Rated IP66 on frontprotected against powerful water jets Easy to open 20A Max. fuse amperage 32V DC Max. operating voltage 0.50" (12.70 mm) mounting hole Fuse sold separately (p. 34) Weight: 0.1 lb (0.04 kg)
5022 Replacement cap for 5021
32V DC 30A (per circuit) 100A (per block) AGC or MDL Fuses #8-32 with Captive Star Lock washer #8 Screw (M4)
Weight lb (kg) 0.55 (0.25) 0.48 (0.22)
5064
For use with ATO or ATC fuses Supplied with 12 AWG pigtails 30A Max. fuse amperage Fuse sold separately (p. 35) Weight: 0.1 lb (0.04 kg)
0.830" 21.08mm
5006
PN 5006
Features
Snap-on terminal cover insulates all conductive parts, satisfying ABYC/USCG requirements Accepts wire sizes 184 AWG from sides or bottom Terminal screws compress fuse blades within blocks for low resistance connections Fuses sold separately (p. 34)
For use with ATOor ATC fuses Supplied with 12 AWG pigtails 30A Max. fuse amperage Fuse sold separately (p. 35) Weight: 0.2 lb (0.09 kg)
5065
Specifications
Vmxo Voltage Max. Operating Imxo Amperage Max. Operating MAXI Fuses available Mounting 32V DC 80A 3080 Amps #10 Screws
38
DC
CIRCUIT PROTECTION
5035
5037
Specifications
Vmxo Voltage Max. Operating Imxo Amperage Max. Operating Imxo Amperage Max. Operating Fuse Type Screw Terminal Mounting
[B]
1.518" 38.57mm
5028
[B]
5033
[C] [D]
[D]
[C]
[A]
[A]
5025
5035, 5037
PN 5028 5033 5025 5030 5029 5034 5026 5031 5035 5037 Circuits 6 6 6 6 12 12 12 12 6 6 Cover Yes Yes Yes Yes Yes Negative Bus #10-32 stud #10-32 stud #10-32 stud #10-32 stud [A] Width in (mm) 3.32 (84.20) 3.32 (84.20) 3.32 (84.20) 3.32 (84.20) 3.32 (84.20) 3.32 (84.20) 3.32 (84.20) 3.32 (84.20) 2.13 (54.23) 2.13 (54.23) [B] Mounting Centers in (mm) 2.50 (63.50) 2.50 (63.50) 2.50 (63.50) 2.50 (63.50) 2.50 (63.50) 2.50 (63.50) 2.50 (63.50) 2.50 (63.50) 1.37 (34.93) 1.37 (34.93) [C] Height in (mm) 3.65 (92.76) 3.65 (92.76) 4.89 (124.31) 4.89 (124.31) 5.23 (132.84) 5.23 (132.84) 6.47 (164.39) 6.47 (164.39) 5.17 (131.32) 5.17 (131.32) [D] Mounting Centers in (mm) 2.64 (67.03) 2.64 (67.03) 3.88 (95.58) 3.88 (95.58) 4.22 (107.11) 4.22 (107.11) 5.46 (138.66) 5.46 (138.66) 4.22 (107.11) 4.22 (107.11) Weight lb (kg) 0.42 (0.19) 0.42 (0.19) 0.55 (0.25) 0.47 (0.21) 0.68 (0.31) 0.59 (0.27) 0.75 (0.34) 0.65 (0.29) 0.40 (0.18) 0.35 (0.16)
5030
5029
5034
Example
Example
Switched Circuits
Fish Finder
Two optional PN 9217 Terminal Block Jumpers allow three 24-hour circuits
GPS Stereo
Switched Circuits
Radio Dash GPS
Switched Circuits
Baitwell Fish Finder Horn
House Battery
Switch
24-Hour Circuits
Bilge Pump Clock Alarm
Two optional PN 9217 Terminal Block Jumpers allow three 24-hour circuits
Switch
5028, 5033
House Battery
5035, 5037
5026
5031
39
DC
CIRCUIT PROTECTION
5191
Features
2151
7720
Appropriate for DC Main, inverter, windlass, and bow thruster circuit protection Weatherproofsuitable for small open-cockpit boats and other harsh environments Insulating cap prevents accidental shorts Fuses sold separately (p. 36) 58V DC 300A 30300 Amps
Specifications
Vmxo Voltage Max. Operating Imxo Amperage Max. Operating Terminal Fuses Available
Regulatory
Features
Sealed cover protects fuses from the harsh marine environment and satisfies ABYC/USCG insulation requirements Cover breakouts allow wire access in three directions Accepts Blue Sea Systems square format standard or custom label Fuses sold separately (p. 36)
Specifications
0.43" 11.0mm 1.18" 30.0mm
0.43" 11.0mm
1.83" 46.5mm
Vmxo Voltage Max. Operating Wire Size to Meet Rating Mounting holes Terminal Stud Size Terminal Screw Size
32V DC 2/0 AWG (70 mm) Accept 1 4 " (M6) Screws M8 x 1.25 M5 x 0.8 Stainless Steel (7720 only)
2151
5191
Regulatory
E marked Meets ISO 8846 and SAE J1171 external ignition protection requirements IP66 protected against powerful water jets (see inside back cover)
PN 7720 7721 Fuse Type AMI or MIDI MEGA or AMG Maximum Amperage Rating 200A 300A Recommended Screw Torque 27 in-lb (3.0 N-m) Recommended Stud Torque 120 in-lb (13.56 N-m) 120 in-lb (13.56 N-m) Weight 0.4 lb (0.18 kg) 0.4 lb (0.18 kg)
Specifications Vmxo Voltage Maximum Operating Imxo Amperage Maximum Operating Wire Size to Meet Rating MEGA / AMG Fuses available
4.92" 125mm
PN 5001
Cover Yes
40
DC
Allows use of Class T fuses for high speed circuit protection of electronic equipment and inverters
Accepts a wide range of ANL fuse amperages for a versatile fusing system
CIRCUIT PROTECTION
Features
Accepts 3 8" (M10) ring terminals Insulating cover satisfies ABYC/USCG insulation requirements Cover breakouts allow wire access in any direction Insert molded studs ensure secure fuse mounting Stainless steel studs provide resistance to corrosion and high torque UL 94-V0 base resists high heat Fuse sold separately (p. 37) For compatible enclosure,
PN 2718, see page 64 5005
Specifications
Vmxo Voltage Max. Operating Imxo Amperage Max. Operating Cable Size Fuse Mounting Blocks Class T Fuses available
NOTE: 5502 replaces 5002 Current design reduces cost, maintains performance and improves insulating cover
PN 5502 Cover Yes Terminal Stud Size 3 8"-16 (M10) Max. Stud Torque 190 in-lb (21.47 N-m) Mounting 1/4" (M6) Screws Weight 1.55 lb (0.70 kg)
5503
1.320" 33.53mm
Features
NOTE: 5503 replaces 5003 Current design reduces cost, maintains performance and improves insulating cover
2.300" 58.42mm
Accepts 5 16" (M8) ring terminals Insulating cover satisfies ABYC/USCG insulation requirements Cover breakouts allow wire access in any direction Insert molded studs ensure secure fuse mounting Stainless steel studs provide resistance to corrosion and high torque UL 94-V0 base resists high heat Fuse sold separately (p. 37) 5503 32V DC 5 16"-18 (M8) Up to 4/0 AWG Tin-Plated Copper 35750 Amps
Maximum Torque 110 in-lb (12.40 N-m) 110 in-lb (12.40 N-m) Mounting Holes Accept #10 (M5) Screw Accept #10 (M5) Screw
Specifications
Vmxo Voltage Max. Operating Terminal Stud Size Cable Size Fuse Mounting Blocks ANL Fuses Available
Insulating Imxo Amperage Cover Maximum Operating Yes Yes 300A 300A 750A
5004/5005 32V DC 5 16"-18 (M8) Up to 4/0 AWG Tin-Plated Copper 35300 Amps
Cable Size AWG Up to 2/0 Up to 2/0 Up to 4/0 Weight lb (kg) 0.18 (0.08) 0.35 (0.16) 1.45 (0.66)
5004, 5005
1.649" 41.87mm
2.300" 58.42mm
Nordhavn Yachts protect high amp loads with multiple Blue Sea Systems Class T and ANL fuse blocks on the Nordhavn 60 motor yacht. Photo: David J. Shuler
5005
5503
41
DC
CIRCUIT PROTECTION
7725
Features
Three 30A200A AMI or MIDI Fuses for high-amp circuits including panel feeds, windlasses, and stereo amplifiers Four 1A20A ATOor ATC Fuses for circuits including bilge pumps, alarms and clock memory Sealed cover protects fuses from the harsh marine environment Integrated connector plug eliminates loose wires and provides a secure, waterproof connection Ignition protected fuse block meets Coast Guard and ABYC requirements for installation on gasoline or diesel powered boats Fuses sold separately (p. 35 and 36)
EXAMPLES OF 24 HOUR / MIDI AMIFUSE CIRCUITS BATTERY CHARGER HIGH CAPACITY BILGE PUMP EXAMPLES OF SWITCHED / MIDI AMIFUSE CIRCUITS DASH/HELM PANEL FEED STEREO WINDLASS
EXAMPLES OF SWITCHED / MIDI AMIFUSE CIRCUITS DASH/HELM PANEL FEED STEREO WINDLASS
Specifications
Imxo Amperage Max. Operating (combined) Vmxo Nominal Operating Voltage Minimum Cable Size to Meet Ratings Recommended Ring Terminal Stud Size Stud Torque 280A 12V DC 4/0 AWG (120 mm) M8 (5/16") M8 x 1.25 15 ft-lb (20.3 N-m) 240A 170A 30A200A 2/0 AWG (70 mm) M5 x .8 x 10 27 in-lb (3.0 N-m) 50A 20A 1A20A
EXAMPLES OF 24 HOUR / MIDI AMIFUSE CIRCUITS BATTERY CHARGER HIGH CAPACITY BILGE PUMP EXAMPLES OF SWITCHED / MIDI AMIFUSE CIRCUITS DASH/HELM MAIN PANEL
EXAMPLES OF SWITCHED / MIDI AMIFUSE CIRCUITS DASH/HELM PANEL FEED STEREO WINDLASS
Regulatory
E marked, Meets ISO 8846 ignition protection, and SAE J1171 external ignition protection requirements IP66protected against powerful water jets (see inside back cover)
Ratings are dependent on input cable sized for appropriate amperages. PN 7725 7731B Description SafetyHub 100 Fuse Block Connector Plug with 12" Harness FCi 2.8mm Included in Retail Package Yes Yes Weight lb (kg) 1.1 (0.5) 0.13 (0.06)
42
DC
CIRCUIT PROTECTION
2155 Remote Control Contura Switch Action: SPDT, ON-ON (page 111)
7727
Features
7748
Features
Four 30A200A AMI or MIDI Fuses for high-amp circuits including panel feeds, windlasses, and stereo amplifiers Six 1A30A ATO or ATC Fuses for circuits including bilge pumps, electronics and lights Sealed cover protects fuses from the harsh marine environment Negative bus provides common location for negative collection Circuit identification label with write-on capability Fuse puller easily removes ATO or ATC fuses Cover provides storage space for two spare ATO or ATC and two spare AMI or MIDI fuses and mounting screws Fuses sold separately (p. 35 and 36)
Battery control from a remote location increases safety and convenience Manual control knob switches high-amp circuits for emergency battery disconnect or servicing Up to three switched 30A200A AMI or MIDI Fuses for high-amp circuits including panel feeds, windlasses, and stereo amplifiers Four 24-hour 1A20A ATO or ATC Fuses for circuits including bilge pumps, alarms, and clock memory Integrated connector plugs eliminate loose wires and provide a secure connection Must be mounted in a dry location Fuses sold separately (p. 35 and 36)
Specifications
Imxo Amperage Max. Operating (combined) Vmxo Voltage Nominal Operating Minimum Cable Size to Meet Ratings Recommended Ring Terminal Stud Size Stud Torque Internal Battery Switch Ic Continuous Amperage Rating I10 Cranking Rating: 10 sec. 280A 12V DC 4/0 AWG (120 mm) M8 (5/16") M8 x 1.25 15 ft-lb (20.3 N-m) 240A 1,000A 240A 170A 30A200A 2/0 AWG (70 mm) M5 x .8 x10 27 in-lb (3.0 N-m) 50A 20A 1A20A
Specifications
Imxo Amperage Max. Operating (combined) Vmxo Voltage Nominal Operating Minimum Cable Size to Meet Ratings Recommended Ring Terminal Stud Size Stud Torque 280A 12V DC, 24V DC, 32V DC 4/0 AWG (120 mm) M8 (5/16") M8 x 1.25 15 ft-lb (20.3 N-m) 280A 170A 30A200A 2/0 AWG (70 mm) M5 x .8 x 10 27 in-lb (3.0 N-m) 50A 25A 1A30A #8-32 x 6.5 mm 18 in-lb (2.0 N-m)
Regulatory
E marked, Meets ISO 8846 ignition protection, and SAE J1171 external ignition protection requirements
Ratings are dependent on input cable sized for appropriate amperages. PN 7727 Description SafetyHub 250 Fuse Block with Remote Battery Switch Remote Control Switch Connector Plug with 12" Harness FCi 2.8mm Connector Plug with 12" Harness Molex MX -150 Engine Link Bus Included in Retail Package Weight lb (kg) Yes Yes Yes Yes Yes 2.1 (1.0) 0.25 (0.11) 0.13 (0.06) 0.10 (0.05) 0.05 (0.02)
Regulatory
E marked, Meets ISO 8846 ignition protection, and SAE J1171 external ignition protection requirements IP66protected against powerful water jets (see inside back cover)
Ratings are dependent on input cable sized for appropriate amperages. PN 7748 Description SafetyHub 150 Fuse Block Included in Retail Package Yes Weight lb (kg) 1.90 (0.86)
43
DC
Product
Fuses*
GMA AGA AGC MDL ATM ATO or ATC MAXI
CIRCUIT PROTECTION
AC
DC
AC
DC
AC
DC
Page no.
34
34
1,000A DC 32V DC 20A 5 -
34
1,000A DC 32V DC .2510A: 250V AC .2530A 5 -
34
1,000A DC 32V DC 37.5A: 250V AC 330A 2 -
35
1,000A DC 32V DC 530A 2 -
35
1,000A DC 32V DC 1-30A 2 -
35
1,000A DC 32V DC 30-80A 1 -
Iic Interrupting Capacity DC 1,000A DC Vmxo Maximum Voltage DC 32V DC Vmxo Maximum Voltage AC Amperage Range Quantity Per Package Regulatory
510A: 125V AC 13A: 250V AC 110A 3 -
* Certain amperages of GMA, AGC, and MDL fuses are AC/DC rated. See product page for specific ratings
Product
Terminal (MRBF)
AMI or MIDI
MEGA or AMG
CLASS T
ANL
36
10,000A @ 14V DC 5,000A @ 32V DC 2,000A @ 58V DC 30300A 1 SAE J1171 IP66 protected against powerful water jets
36
5,000A @ 16V DC 2,000A @ 32V DC 32V DC 30200A 2 ISO 8846 and SAE J1171 when used with Blue Sea Systems' SafetyHubs and Safety Fuse Blocks
36
2,000A @ 32V DC 32V DC 100300A 1 ISO 8846 and SAE J1171 when used with Blue Sea Systems' SafetyHubs and Safety Fuse Block PN 7721
37
20,000A @160V DC 160V DC 225400A 1 -
37
6,000A @32V DC 32V DC 35750A 1 35500A Meets ISO 8846 and SAE J1171
Vmxo Maximum Voltage 58V DC Amperage Range Quantity Per Package Regulatory
DC
Product
Page no. / Part no. For use with Wire Size Imxo Maximum Amperage Regulatory
38 / 5060
AGC or MDL Accepts 1216 AWG 30A per circuit -
38 / 5061
AGC or MDL Accepts 1218 AWG 30A per circuit -
38 / 5062
AGC or MDL Accepts 1216 AWG 20A per circuit -
38 / 5063
AGC or MDL Supplied with 12 AWG Pigtails 30A per circuit -
38 / 5021
AGC or MDL 20A per circuit IP66 on front protected against powerful water jets
38 / 5064
ATO or ATC Supplied with 12 AWG Pigtails 30A per circuit -
38 / 5065
ATO or ATC Supplied with 12 AWG Pigtails 30A per circuit -
44
DC
Product
Fuse Blocks
ST-Glass MAXI ST-Blade Terminal (MRBF) Terminal (MRBF)
CIRCUIT PROTECTION
Page no. / Part no. For use with Vmxo Maximum Voltage Imxo Maximum Amperage per circuit Imxo Maximum Amperage per block Amperage Range
38 / 5015, 5018
AGC or MDL 32V DC 30A 100A .2530A
38 / 5006
MAXI 32V DC 80A 80A 3080A
40 / 5191
Terminal (MRBF) 58V DC 300A 300A 30300A Meets SAE J1171 when used with Blue Sea Systems' Terminal (MRBF) Fuses Meets IP66 when used with Blue Sea Systems' Terminal (MRBF) Fuses
40 / 2151
Terminal (MRBF) 58V DC 300A 300A 30300A Meets SAE J1171 when used with Blue Sea Systems' Terminal (MRBF) Fuses Meets IP66 when used with Blue Sea Systems' Terminal (MRBF) Fuses ANL
Regulatory
Product
MEGA or AMG
Class T
ANL
40 / 5001
MEGA or AMG
40 / 7720
AMI or MIDI 32V DC 200A 30200A ISO 8846 SAE J1171 IP66-protected against powerful water jets
40 / 7721
MEGA or AMG 32V DC 300A 100300A ISO 8846 SAE J1171 IP66-protected against powerful water jets SafetyHub 150
41 / 5502
Class T 160V DC 400A 225400A
41 / 5005
ANL 32V DC 300A 35300A -
41 / 5503
ANL 32V DC 750A 35750A -
Vmxo Maximum Voltage 32V DC Imxo Maximum 300A Amperage per block 100300A Amperage Range Regulatory
Product
SafetyHub 100
SafetyHub 250
Page no. / Part no. For use with Vmxo Nominal Operating Voltage Imxo Maximum Total Amperage (combined) Imxo Maximum Amperage (per block) Imxo Maximum Amperage (per circuit) Available Amperages Regulatory
42 / 7725
AMI or MIDI and ATO or ATC 12V DC 280A AMI or MIDI: 240A AMI or MIDI: 170A AMI or MIDI: 30200A ATO or ATC: 50A ATO or ATC: 20A ATO or ATC: 120A
43 / 7748
AMI or MIDI and ATO or ATC 12V DC, 24V DC, 32V DC 280A AMI or MIDI: 280A AMI or MIDI: 170A AMI or MIDI: 30200A ATO or ATC: 50A ATO or ATC: 25A ATO or ATC: 130A
43 / 7727
AMI or MIDI and ATO or ATC 12V DC 280A AMI or MIDI: 240A AMI or MIDI: 170A AMI or MIDI: 30200A ISO 8846, SAE J1171 ATO or ATC: 50A ATO or ATC: 20A ATO or ATC: 120A
45
DC
CIRCUIT PROTECTION
Features
Branch circuit breakers - also used for 24-hour circuit protection Quick connect or screw terminal style Compact design enables high density circuit protection configurations Push-to-reset operation Trip Free design cannot be held ON during fault current condition Optional push button waterproof boot protects circuit breaker in wet environments Interrupting Capacity 3,000A @ 14.7V DC 2,500A @ 28V DC 32V DC See table -10C 60C Thermal trip, manual reset #8 Screw Terminals or 14" Male Quick Connect Terminals 6 in-lb max. See www.bluesea.com 3 8"-27 UNS 0.06 lb (0.03 kg)
7054
0.335" 8.51mm D BUSHING
2132
Specifications
Iic Vmxo Voltage Max. Operating Itr Amperage Trip Reference Tmno Temperature Min. Operating Tmxo Temperature Max. Operating Type Terminals Screw Terminal Torque Trip Time Delay Thread Weight
0.496" 12.60mm
0.049" 1.25mm
2.307" 58.60mm
1.225" 30.12mm
0.571" 14.50mm
0.496" 12.60mm
0.049" 1.25mm
Regulatory
E marked UL RecognizedUL 1077UL/cUL (USA and Canada), TUV certified Meets UL 1500 and ISO 8846 external ignition protection requirements
See page 121 for ABYC Interrupting Capacity Requirements.
2.024" 51.41mm
1.225" 30.12mm
0.571" 14.50mm
#8 Screw Terminals
Screw Terminals PN 2129 2130 2131 2132 2133 2134 2135 2136 2137
Quick Connect Terminals PN 7050 7052 7053 7054 7056 7057 7058 7059 7061
0.347" 8.80mm
Specifications
Regulatory
IP67protected against immersion up to 1 meter for 30 minutes
(see inside back cover)
4135
PN 4135 4136
4136
Description Clear White Black
4137
4137
46
AC
DC
CIRCUIT PROTECTION
2142
Specifications
Iic Vmxo Voltage Max. Operating Itr Amperage Trip Reference Tmno Temperature Min. Operating Tmxo Temperature Max. Operating Type Terminal Stud Terminal Stud Torque Trip Time Delay Mounting Thread Weight 0.15 lb (0.68 kg)
1.345" 34.2mm
.449" 11.4mm
45
1.189" 30.2mm
Front View
Regulatory
SAE J1428, SAE J553, UL 1077 Meets UL 1500 external ignition protection requirements
See page 121 for ABYC Interrupting Capacity Requirements.
PN 2138 2139 2140 2141 2142 2143 Itr Amps 15A DC 20A DC 30A DC 40A DC 50A DC 60A DC
.570" DIA. 14.5mm
Side View
.764" 19.4mm
Back View
.220" DIA. 5.6mm
1150
(circuit breakers not included)
Dimensions (WxH): 4.88 x 4.75 in (123.83 x 120.65 mm) Depth: 0.50 in (12.70 mm) Weight: 0.60 lb (0.27 kg)
Grady White installs Blue Sea Systems Push Button Reset-Only Circuit Breakers to protect medium duty loads on board the Canyon 271.
47
DC
Provides medium duty circuit protection for 25 to 150 Amp loads when switching and circuit protection are both required
CIRCUIT PROTECTION
7087
Regulatory
E marked Meets SAE J1171 external ignition protection requirements, AIC ratings achieved using SAE J1625 IP67protected against immersion up to 1 meter for 30 minutes (see inside back cover)
See page 121 for ABYC Interrupting Capacity Requirements.
Panel Mount PN 7080 7081 7082 7083 7084 7085 7086 7087 7088 7089 Surface Mount PN 7180 7181 7182 7183 7184 7185 7186 7187 7188 7189 Itr Amps 25A DC 30A DC 40A DC 50A DC 60A DC 70A DC 80A DC 100A DC 120A DC 150A DC
2.41" 61.11mm
1.90" 48.1mm
Provides mounting for Cooper Bussmann 285-Series or 185-Series Panel Mount Circuit Breakers
7187
1.895" 48.13mm 1.050" 26.67mm 1.24" 31.5mm .86" 21.8mm .49" 12.5mm
7198
7098 1477
3.200" 81.28mm
2.484" 63.09mm
2.230" 56.64mm
Description Self-trimming molded rubber bezel Circuit breaker adapter bezel allows circuit breaker mounting in a 2-1/8" round hole Provides circuit breaker mounting in the 360 Panel System
48
DC
Provides heavy duty circuit protection for 25 to 200 Amp loads when switching and circuit protection are both required
Single lever operationclearly visible Trip-freecannot be held closed after trip Self-trimming case eliminates need for mounting panels or trim bezels Round case for easy installation with standard sized hole saw (panel mount models) Large clearance around terminal studs accepts up to 1/0 AWG lugs Recessed mounting holes for clean appearance Robust 5 16"-18 terminals provide high torque connections Interrupting Capacity 5,000A @ 12V DC 3,000A @ 24V DC 1,500A @ 42V DC 48V DC See table -40C 85C Thermally Responsive Bi-Metal Blade Type IIISwitchable/Manual ResetTrip 5 16"-18 75 in-lb max. See www.bluesea.com Accepts #10 (M5) Screw 0.50 lb (0.23 kg) 0.58 lb (0.26 kg)
7044
0.300" 7.62mm MOUNTS IN 2.125 DIA. 53.97mm DIA. HOLE
CIRCUIT PROTECTION
Specifications
Iic
Vmxo Voltage Max. Operating Itr Amperage Trip Reference Tmno Temperature Min. Operating Tmxo Temperature Max. Operating Type Class Free Terminal Stud Terminal Stud Torque Trip Time Delay Mounting Hole Weight Panel Mount Weight Surface Mount
3.386" 86.01mm
2.750" 69.85mm
2.125" 53.97mm
2.105" 53.47mm
2.260" 57.42mm
0.732" 18.59mm
1.750" 44.45mm
Regulatory
E marked Meets SAE J1171 external ignition protection requirements IP66protected against powerful water jets (see inside back cover)
See page 121 for ABYC Interrupting Capacity Requirements.
Panel Mount PN 7035 7036 7038 7039 7040 7041 7042 7043 7044 7046 7048 7049
Surface Mount PN 7135 7136 7138 7139 7140 7141 7142 7143 7144 7146 7148 7149
Itr Amps 25A DC 30A DC 40A DC 50A DC 60A DC 70A DC 80A DC 90A DC 100A DC 120A DC 150A DC 200A DC
7140
1.625" 41.28mm
3.439" 87.35mm
2.562" 65.07mm
2.125" 53.97mm
2.323" 59.00mm
1.797" 45.64mm
Blue Sea Systems 187-Series Thermal Circuit Breakers are part of the electrical system aboard the Sabre Salon Express 48.
49
AC
DC
PN 7200 7201 7202 7347 7299 7204 7205 7206 7208 7209 7210 7212 7213 7214 7216 7217 7218 7220 7221 7222 7224 7225 7226 7228 7229 7230
Color Black Red White Black White Black Red White Black Red White Black Red White Black Red White Black Red White Black Red White Black Red White
Poles 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1
Itr DC Amps 5A DC 5A DC 5A DC 8A DC 8A DC 10A DC 10A DC 10A DC 15A DC 15A DC 15A DC 20A DC 20A DC 20A DC 25A DC 25A DC 25A DC 30A DC 30A DC 30A DC 40A DC 40A DC 40A DC 50A DC 50A DC 50A DC
Itr AC Amps 5A AC 5A AC 5A AC 8A AC 8A AC 10A AC 10A AC 10A AC 15A AC 15A AC 15A AC 20A AC 20A AC 20A AC 25A AC 25A AC 25A AC 30A AC 30A AC 30A AC 40A AC 40A AC 40A AC 50A AC 50A AC 50A AC
PN 7232 7233 7234 7235 7348 7294 7236 7260 7237 7238 7349 7295 7239 7240 7241 7242
Color Black White Black White Black White Black White Black White Black White Black White Black White
Poles 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2
Itr DC Amps 10A DC 10A DC 15A DC 15A DC 16A DC 16A DC 20A DC 20A DC 30A DC 30A DC 32A DC 32A DC 40A DC 40A DC 50A DC 50A DC
Itr AC Amps 10A AC 10A AC 15A AC 15A AC 16A AC 16A AC 20A AC 20A AC 30A AC 30A AC 32A AC 32A AC 40A AC 40A AC 50A AC 50A AC
CIRCUIT PROTECTION
7202
7200
7233
Features
The industry standard circuit breaker for Blue Sea Systems electrical panels Single pole is frequently used for AC or DC Branch circuit protection Double pole is typically used for AC Main circuit protection Trip Free cannot be held closed after trip See Interrupting Capacity Table 65V DC / 250V AC See table -40C 85C 10,000 @ rated amps and volts Magnetic HydraulicTrip free #10-32 Stainless Steel 1415 in-lb Recommended See www.bluesea.com #6-32 Stainless Steel (included) 68 in-lb Recommended 0.17 lb (0.08 kg) 0.30 lb (0.14 kg)
Specifications
Iic Interrupting Capacity Vmxo Voltage Max. Operating Itr Amperage Trip Reference Tmno Temperature Min. Operating Tmxo Temperature Max. Operating Cs Switching Cycles Type Terminal Screw Terminal Screw Torque Trip Time Delay Mounting Screw Mounting Screw Torque Weight Single Pole Weight Double Pole
1.660" 42.16mm
Regulatory
E marked, TUV certified, CSA certified, UL 1077 recognized
OVERALL DEPTH 2.00" 50.80mm 1.050" 26.67mm 2.000" 50.80mm
OVERALL DEPTH 2.00" 50.80mm 0.750" 19.05mm
2.000" 50.80mm
1.050" 26.67mm
NEW
0.170" 4.32mm
0.750" 19.05mm
0.170" 4.32mm
Surface mount option for mounting single and double pole circuit breakers
Wire glands included for secure installation of circuit breakers Accepts A-Series toggle and A and C-Series Flat Rocker Circuit Breakers, LEDs (p. 115) and Square Format Labels (p. 117) for custom configurations
3131
8072
PN 8072 8173 Description Single pole mounting panel Double pole mounting panel
8173
Width in (mm) 2.63 (66.80) 2.63 (66.80) Depth in (mm) 3.75 (95.25) 3.75 (95.25) Weight lb (kg) 0.08 (0.04) 0.08 (0.04) PN 3131 Description Circuit Breaker Enclosure
50
AC
DC
CIRCUIT PROTECTION
7403
7425
7574
Flat Rocker Standard circuit breaker used on the 360 Panel System (1200 Series) Flat actuator resists accidental switching by being flush in the ON position
Restricted OFF Rocker Actuator shows white in the OFF position Restricted OFF actuator can only be switched to OFF by insertion of small screwdriver into slot
Features
White actuator indicates OFF position Single pole is available in Flat Rocker and Restricted Off styles Single pole is frequently used for AC or DC Branch circuit protection Double pole is available in Flat Rocker and Raised Rocker styles Double pole is typically used for AC Main circuit protection Raised Rocker actuator style is used for AC source selection on the 360 Panel System International ON and OFF symbols support vertical or horizontal mounting See Interrupting Capacity table below 32V DC / 250V AC See table -40C 85C 10,000 @ rated amps and volts Magnetic HydraulicTrip free #10-32 Stainless Steel 1415 in-lb Recommended (load terminal is 30 angled) See www.bluesea.com #6-32 Stainless Steel (included) 68 in-lb Recommended 0.16 lb (0.07 kg) 0.38 lb (0.17 kg)
Specifications Iic Interrupting Capacity Vmxo Voltage Max. Operating Itr Amperage Trip Reference Tmno Temperature Min. Operating Tmxo Temperature Max. Operating Cs Switching Cycles Type Terminal Screw Terminal Screw Torque Trip Time Delay Mounting Screw Mounting Screw Torque Weight Single Pole Weight Double Pole
7410 7571 7411 7572 7412 7573 EN60934 - TUV (Europe) Iic Interrupt 1,500A 1,500A 7413 7574 7414 7575 7415 7576 7416 7577 7417
0.200" 5.08mm
0.750" 19.05mm
50
Raised Rocker Standard circuit breaker for AC Source Select panels in the 360 Panel System
30A
50
2.310" 58.67mm
Cut out Dimensions Specifications subject to change. See bluesea.com for current information.
51
AC
DC
CIRCUIT PROTECTION
7250*
7267
7270
7251
7287
AC
DC
DC
PN 7350 7351 7352 7353 7354 7355 7244 7246 7248 7250 7250I 7365 7251 7254 7256 7258 7267 7268 7269 7287 7288 7289 7290 7270 7271 Color White White White White White White White White White White Red White White White White White White White White White White White White White White Poles 1 1 1 1 1 1 1 1 1 1 1 2 2 2 2 2 2* 2* 2* 3 3 3 3 3* 3*
DC Features
Large frame provides stud termination for 5300 Amp loads Provides overcurrent protection for inverters, bow thrusters, and windlasses Offers high interrupt capacitysuitable for Main circuit protection Trip Free cannot be held closed after trip
Itr DC Amps 5A DC 10A DC 15A DC 20A DC 25A DC 30A DC 50A DC 60A DC 80A DC 100A DC 100A DC 150A DC 175A DC 200A DC 250A DC 300A DC
Itr AC Amps 5A AC 10A AC 15A AC 20A AC 25A AC 30A AC 50A AC 60A AC 80A AC 100A AC 100A AC 30A AC 50A AC 60A AC 80A AC 100A AC 50A AC 60A AC 80A AC 100A AC -
AC
Weight lb (kg) 0.28 (0.13) 0.28 (0.13) 0.28 (0.13) 0.28 (0.13) 0.28 (0.13) 0.28 (0.13) 0.36 (0.17) 0.36 (0.17) 0.36 (0.17) 0.36 (0.17) 0.36 (0.17) 0.60 (0.27) 0.60 (0.27) 0.60 (0.27) 0.60 (0.27) 0.60 (0.27) 0.64 (0.31) 0.64 (0.31) 0.64 (0.31) 0.90 (0.41) 0.90 (0.41) 0.90 (0.41) 0.90 (0.41) 0.93 (0.46) 0.93 (0.46)
0.432" 10.97mm 0.750" 19.05mm 2.250" 57.15mm 1.500" 38.10mm 0.750" 19.05mm 1.448" 2.062" 52.37mm 36.78mm
AC Features
Frequently used for 120/240 Volt AC circuit protection Double pole can be used as AC Main circuit breaker to switch hot and neutral or two hots in 120/240 Volt AC Branch applications Triple pole can be used as 120/240 Volt AC Main circuit breaker to switch both lines (hots) and neutral Double and triple pole circuit breakers will trip all poles if any one pole trips
DC and AC Specifications
Iic Interrupting Capacity Vmxo Voltage Max. Operating Itr Amperage Trip Reference Tmno Temperature Min. Operating Tmxo Temperature Max. Operating Cs Switching Cycles Type Terminal Stud Terminal Stud Torque Trip Time Delay Mounting Screw Mounting Screw Torque See Interrupt Capacity Table See Interrupt Capacity Table See table -40C 85C 10,000 @ rated amperage and voltage Magnetic HydraulicTrip free 1 4"-20 Tin-Plated Brass 35 in-lb max. See www.bluesea.com #6-32 Stainless Steel (included) 68 in-lb Recommended
Regulatory
7250I ONLYmeets SAE J1171, UL 1500, and ISO 8846 external ignition protection requirements
Interrupting Capacity Table (see ABYC Requirements page 121)
UL 1077 - UL/CSA (US/Canada) Poles* 1 Pole* 1 Pole* PN 7250I 2 and 3 Pole Vmxo Volts 80V DC 125V AC 250V AC 48V DC 125V AC 65V DC 125/250V AC 250V AC Itr Amps 5100A 5100A 5100A 100A 100A 150300A 30100A 30100A Iic Interrupt 10,000A 5,000A 5,000A 5,000A 1,500A 5,000A 5,000A 5,000A No agency approvals
2.475" 62.86mm 1.850" 47.0mm 0.406" 10.31mm
Cutout Dimensions
8088
** 1/4" STUD
3 position 5.25 (133.35) 3.75 (95.25) mounting panel 8 position 5.25 (133.35) 7.50 (190.50) mounting panel Panel Plug Kit -
8087
2.500" 2.062" 63.50mm 52.37mm 1.438" 36.53mm
1.940" 49.28mm
8089
#6-32
0.750" 19.05mm
0.150" 3.81mm
0.281" 7.14mm
8087
52
AC
DC
CIRCUIT PROTECTION
7540
7551
7554
7580
7568
AC
DC
DC
DC Features
White actuator indicates OFF position Large frame provides stud termination for 5300 Amp loads Flat rocker actuator is flush in the ON position, reducing the risk of accidental switching Provides overcurrent protection for inverters, bow thrusters, and windlasses Trip Freecannot be held closed after trip
AC Features
AC
Used for 120/240 Volt AC circuit protection Double pole can be used as AC Main circuit breaker to switch hot and neutral or two hots in 120/240 Volt AC Branch applications Triple pole can be used as 120/240 Volt AC Main circuit breaker to switch both lines (hots) and neutral Double and triple pole circuit breakers will trip all poles if any one pole trips
PN 7540 7541 7542 7543 7544 7545 7546 7547 7548 7549 7560 7580 7561 7581 7562 7582 Rocker Actuator Flat Flat Flat Flat Flat Flat Flat Flat Flat Flat Flat Raised Flat Raised Flat Raised Flat Raised Flat Raised Flat Flat Flat Flat Raised Flat Raised Flat Raised Flat Raised Flat Flat Poles 1 1 1 1 1 1 1 1 1 1 2 2 2 2 2 2 2 2 2 2 2* 2* 2* 3 3 3 3 3 3 3 3 3* 3* Itr DC Amps 5A DC 10A DC 15A DC 20A DC 25A DC 30A DC 50A DC 60A DC 80A DC 100A DC 150A DC 175A DC 200A DC 250A DC 300A DC Itr AC Amps 5A AC 10A AC 15A AC 20A AC 25A AC 30A AC 50A AC 60A AC 80A AC 100A AC 30A AC 30A AC 50A AC 50A AC 60A AC 60A AC 80A AC 80A AC 100A AC 100A AC 50A AC 50A AC 60A AC 60A AC 80A AC 80A AC 100A AC 100A AC Weight lb (kg) 0.28 (0.13) 0.28 (0.13) 0.28 (0.13) 0.28 (0.13) 0.28 (0.13) 0.28 (0.13) 0.28 (0.13) 0.36 (0.17) 0.36 (0.17) 0.36 (0.17) 0.51 (0.23) 0.51 (0.23) 0.51 (0.23) 0.51 (0.23) 0.51 (0.23) 0.51 (0.23) 0.51 (0.23) 0.51 (0.23) 0.51 (0.23) 0.51 (0.23) 0.64 (0.31) 0.64 (0.31) 0.64 (0.31) 0.78 (0.35) 0.78 (0.35) 0.78 (0.35) 0.78 (0.35) 0.78 (0.35) 0.78 (0.35) 0.78 (0.35) 0.78 (0.35) 0.93 (0.46) 0.93 (0.46)
Specifications
Iic Interrupting Capacity Vmxo Voltage Max. Operating Itr Amperage Trip Reference Tmno Temperature Min. Operating Tmxo Temperature Max. Operating Cs Switching Cycles Type Magnetic HydraulicTrip free Terminal Stud Terminal Stud Torque Trip Time Delay Mounting Screw Mounting Screw Torque See Interrupt Capacity Table See Interrupt Capacity Table See table -40C 85C 10,000 @ rated amperage and voltage 1 4"-20 Tin-Plated Brass 35 in-lb max. See www.bluesea.com #6-32 Stainless Steel (included) 68 in-lb Recommended
Regulatory
SINGLE-POLE CIRCUIT BREAKERS ONLY E marked, meet SAE J1171, UL 1500 and
ISO 8846 external ignition protection requirements, CSA certified, and UL 1077 recognized AC CIRCUIT BREAKERS ONLYTUV certified, CSA certified, and UL 1077 recognized AC AND AC/DC CIRCUIT BREAKERS ONLYE marked
Interrupting Capacity Table (see ABYC Requirements page 121)
UL 1077 - UL/CSA (US/Canada) Poles Vmxo Volts 32V DC 1 Pole 120V AC 240V AC 48V DC 2 and 3 Pole 48V DC 120/240V AC 240V AC Itr Amps 5100A 5100A 550A 150300A 150200A 30100A 30100A Iic Interrupt 5,000A 3,000A 3,500A 5,000A 5,000A EN60934 - TUV (Europe) Iic Interrupt 5,000A 5,000A
7563 7583 7564 7584 7475 7551 7476 7565 7585 7566 7586
7567
0.200" 5.08mm 1.660" 42.16mm 0.156" DIA. 3.96mm
2.550" 64.77mm
7554
53
AC
CIRCUIT PROTECTION
PROPERLY FUNCTIONING
ELCI detects that current is balanced and remains closedcompleting circuit
CLOSED
20 AMPS 20 AMPS
120 VOLT 60 Hz
HOT NEUTRAL GROUND
20 AMPS
CURRENT COIL
However, if electricity leaks from this intended path in these two wires to ground, this condition is called a ground fault. A good example of this is an insulation failure in the wiring of an appliance.
ELCI detects that current is not balanced and opens (trips)breaking circuit
OPENS WHEN AN IMBALLANCE IN CURRENT IS DETECTED
20 AMPS
GROUND FAULT
ELCIs, and the more familiar GFCIs (Ground Fault Circuit Interrupter), are part of a larger family of devices that measure current flow in the hot and neutral wires and immediately switch the electricity off if an imbalance of current flow is detected. ELCIs and GFCIs that are also RCBOs (Residual Current Circuit Breaker) provide overcurrent tripping protection characteristic of a normal circuit breaker. GFCIs are used as branch circuit ground fault protection at the 5mA threshold in potentially wet environments. GFCIs protect against flaws in devices plugged into them, but offer no protection from the danger of a failing hard-wired appliance, such as a water heater or cooktop. In contrast, an ELCI provides additional whole-boat protection. Installed as required within 10 of the shore power inlet, an ELCI provides 30mA ground fault protection for the entire AC shore power system beyond the ELCI. ABYC regulations still require the use of GFCIs in environments described above.
20 AMPS
120 VOLT 60 Hz
HOT NEUTRAL GROUND
19.970 AMPS
CURRENT COIL 0.030 AMPS (30mA) CURRENT LEAKING FROM HOT WIRE
In addition, a faulty ground can occur when the grounding path is broken through a loose connection or broken wire. For instance, a shore power cord ground wire may fail due to constant motion and stress.
FAULTY GROUND
ELCI detects that current is not balanced and opens (trips)breaking circuit
OPENS WHEN AN IMBALLANCE IN CURRENT IS DETECTED SHORT LIMITED TO 0.030 AMPS (30mA)
19.970 AMPS
ELCI
BRANCH CIRCUITS
20 AMPS
120 VOLT 60 Hz
HOT NEUTRAL GROUND POTENTIAL HAZARD BROKEN GROUND
Faulty grounds can be undetectable; a simple continuity test will not necessarily reveal a problem. When these two conditions occur at the same time, the results may be tragic. The combination of a ground fault and a faulty ground can result in metal parts on the boat and under water becoming energized. If an electric drill with faulty internal wiring or a worn cord falls into the bilge, the water in the bilge will become energized, putting the worker and those nearby at risk. In addition to the hazard to people on the vessel, there is a larger danger to swimmers near the boat. While people on board are likely to receive a shock from touching energized metal parts, nearby swimmers could receive a paralyzing dose of electricity and drown due to involuntary loss of muscle control.
MARINE POWER
D O C K
Although ABYC regulations apply only to new boat construction, ELCIs can mitigate dangers and liabilities that exist for any boat owner with a shore power connection. Retrofitting an ELCI to an existing AC system can be a worthwhile safeguard against risk. Since an ELCI/RCBO can serve as the main shore power circuit breaker, it can replace a standard circuit breaker in this application. Alternatively, an ELCI/RCBO can be added between the shore power inlet and the existing main shore power circuit breaker. Safety ground system failures on boats are safety and liability disasters waiting to happen. ELCI protection on each shore power line, combined with protection afforded by GFCIs, will reduce risk to those on the boat, the dock, and in the water surrounding the boat.
360 Panel
54
AC
Residual Current Devices (RCDs) respond to leakage of electrical current outside of the intended circuit path. When the RCD function is combined with a circuit breaker for over current protection, the device is often referred to as an RCBO. In the USA, a device that trips on leakages of nominally 5mA and meets certain standards is called a Ground Fault Circuit Interrupter (GFCI). A device meeting the same standards but with a trip level of 30mA is called an Equipment Leakage Circuit Interrupter (ELCI). The devices below provide GFCI Branch or ELCI Main functions and circuit protection in panel mounted breakers. Features
Trips on short circuit, overload, or leakage to ground For installation in a power distribution panel GFCI Branch - Provides overcurrent and leakage protection per ABYC E-11 for head, galley, machinery and weather deck receptacles ELCI Main - Provides overcurrent and leakage protection per ABYC E-11 for whole boat shore power protection
CIRCUIT PROTECTION
3100
Specifications
Iic Interrupting Capacity Tmno Temperature Min. Operating Tmxo Temperature Max. Operating Cs Switching Cycles Type Mounting Screw Mounting Screw Torque 5,000 Amps -35C 66C 10,000 @ rated amperage and voltage Magnetic HydraulicTrip free #6-32 Stainless Steel 68 in-lb Recommended
3102100
Regulatory
3100 UL 1077, UL 943 Class A 3103, 3104, 3102100, 3106100, 3091, 3092, 3093 UL 1077, UL 943 Class A, UL 1500 AC AND AC/DC CIRCUIT BREAKERS ONLY E marked
Description GFCI Branch ELCI Main ELCI Main ELCI Main ELCI Main ELCI Main ELCI Main ELCI Main
Frame Series A-Series A-Series C-Series C-Series A-Series C-Series C-Series C-Series
Nominal Voltage 120V AC per pole 120V AC per pole 120V AC per pole 120/240V AC per pole 120V AC per pole 230V AC per pole* 230V AC per pole* 240V AC per pole
Actuator Style Flat Rocker Flat Rocker Flat Rocker Flat Rocker White Toggle Flat Rocker Flat Rocker Flat Rocker
Poles 1 2 2 3 2 2 2 2
Itr AC Amperage
Leakage Trip MAIN BRANCH Amps 30A 50A 50A 30A 16A 32A 50A 15A 5mA 30mA 30mA 30mA 30mA 30mA 30mA 30mA
Weight lb (kg) 0.38 (0.17) 0.45 (0.20) 0.85 (0.38) 1.00 (0.45) 0.45 (0.20) 0.85 (0.38) 0.85 (0.38) 0.85 (0.38)
3103
* 230V AC, Typical of Europe 240V AC, For isolation transformer applications
3106100
55
AC
CIRCUIT PROTECTION
Panel enclosure for ELCI Main circuit breakers and other large frame devices. Meets ABYC E-11 when used with an ELCI Main circuit breaker and mounted within 10 feet of the shore power inlet Features
Models available with ELCI Main circuit breakers for 120V 30A, 120V 50A, and 120/240V 50A Blank apertures for custom breaker loading Glass filled polycarbonate base Clear cover allows easy view of circuit breaker status Overlapping cover for strength and increased gasket protection Oversized, formed in place seamless PUR gasket Easily removable stainless steel hinge pin for unobstructed installation Stainless steel latch secures cover without penetrating the enclosure Blank circuit positions accommodate Carling Technologies A and C Series Flat Rocker and ELCI Main circuit breakers Stainless steel mounting hardware included Includes waterproof glands (3116, 3118, 3119) Green LEDs for backlighting and ON indication (3116, 3118, 3119)
6.0" x 6.0" x 4.0" 152 mm x 152 mm x 102 mm 7.6" x 7.4" x 4.7" 192 mm x 188 mm x 120 mm -40C to 85C 10-32 stainless steel 1/4", #12, (6 mm)
3116
Regulatory
IP66Protected against powerful water jets when cover is latched (see inside back cover) Flammability ratingPer UL 508 Toxicity Non-toxic, halogen free, RoHS compliant UL Listed and NEMA 4X rated, NEMA Type 4, 4X, 6, 6P, 12, and 13 Please contact Blue Sea Systems for circuit breaker configurations that are not included on this page. See page 121 for ABYC Interrupting Capacity Requirements.
7.65" 194.2mm 4.96" 126.1mm
PN
8.13" 206.4mm
Description 6 Blank Circuit Positions ELCI Main + 3 Blank Circuit Positions 120V AC ELCI 30A Dual ELCI Main + 2 Blank Circuit Positions ELCI Main + 1 Blank Circuit Position Small Gland PG7, #14 to #10 Single Wire Medium Gland PG16, #14 to #10 Single Wire Large Gland PG29, #8 Cable
Installed Circuit Breakers 1 ELCI Main 120V, 30A, 30mA 2 ELCI Main 120V 30A, 30mA 1 ELCI Main 120V 50A, 30mA 1 ELCI Main 120/240V, 50A, 30mA -
Weight lb (kg) 3.15 (1.43) 4.15 (1.88) 6.50 (2.95) 5.25 (2.38) 6.95 (3.15) 0.07 (0.03) 0.09 (0.04) 0.10 (0.04)
3113 3116
NEW
* SMS panel enclosures are pre-assembled and ready for wire connections. Customers must select wire and entry or exit locations, drill holes, and install the appropriate glands.
4.00" 101.6mm
3126
56
CIRCUIT PROTECTION
GLAND SPECIFICATIONS
3117 SMS Panel Enclosure Includes:
2 ELCI Main 120V 30A, 30mA, 3102100 4 small wire glands, 3124 6 medium wire glands, 3125 4 green ON indicating 120V AC LEDs, 8034 1 red Reverse Polarity indicating 120V AC LED, 8066 1 LED plug 12 circuit breaker mounting screws Backlit circuit label positions 1 AC Main label, 6520-0013 1 Reverse Polarity label, 6520-0360 1 ELCI label, 6520-0580 30 Basic AC labels, 4206 Panel Voltage ID label-120V AC
WIRE SIZE CABLE DIA. RANGE DIMENSIONS
Min. Dia.
#14 to #10 Single Wire Small 3124 .114 in 2.9 mm
Max. Dia.
.250 in 6.4 mm
A. Clearance Hole .492 in (12.5 mm) B. Max. O. A. Length 1.17 in (29.7 mm) C. Wrenching Flats .59 in (15.0 mm)
Reference diagram below
.230 in 5.8 mm
.530 in 13.9 mm
A. Clearance Hole .886 in (22.5 mm) B. Max. O. A. Length 1.66 in (42.2 mm) C. Wrenching Flats 1.05 in (26.7 mm)
Reference diagram below
Medium 3125
#6 Cable
.590 in 15.0 mm
.990 in 25.4 mm
A. Clearance Hole 1.470 in (37.3 mm) B. Max. O. A. Length 2.23 in (56.6 mm) C. Wrenching Flats 1.66 in (42.2 mm)
Reference diagram below
Large 3126
SEALING NUT
KEY Red 120V AC LED Green 120V AC LED LED Plug Backlit circuit label position Specifications subject to change. See bluesea.com for current information.
57
DC
Product
CIRCUIT PROTECTION
AC
DC
Page no.
46
3,000A @ 14.7V DC 32V DC 340A E marked, UL 1077, TUV certified, UL 1500, ISO 8846
46
3,000A @ 14.7V DC 2,500A @ 28V DC 32V DC 340A E marked, UL 1077, TUV certified, UL 1500, ISO 8846
47
5,000A @ 32V DC 3,000A @ 120V AC* 32V DC / 120V AC* 1560A
48
3,000A @ 48V DC 48V DC 25150A
48
3,000A @ 48V DC 48V DC 25150A E marked, SAE J1171, IP67
49
5,000A @ 12V DC 3,000A @ 24V DC 1,500A @ 42V DC 48V DC 25200A E marked, SAE J1171, IP66
49
5,000A @ 12V DC 3,000A @ 24V DC 1,500A @ 42V DC 48V DC 25200A E marked, SAE J1171, IP66
Iic Interrupting Capacity 2,500A @ 28V DC Vmxo Max. Voltage Available Amperages Regulatory
SAE J1428, SAE J553, E marked, UL 1077, UL 1500 SAE J1171, IP67
* Medium Duty Push Button Reset-Only Circuit Breakers are AC/DC rated AIC ratings achieved using SAE J1625
AC
Product
DC
Page no. Iic Interrupting Capacity DC Iic Interrupting Capacity AC Vmxo Max. Voltage DC Vmxo Max. Voltage AC Poles Available Amperages Regulatory
50
7,500A @ 65V DC 3,000A @ 120V AC 3,000A @ 250V AC 65V DC 250V AC 1 550A E marked, TUV certified, CSA certified, UL 1077
51
5,000A @ 32V DC 3,000A @ 125V AC 1,500A @ 250V AC 32V DC 250V AC 1 550A E marked, TUV certified, CSA certified, UL 1077
51
5,000A @ 32V DC 3,000A @ 125V AC 1,500A @ 250V AC 32V DC 250V AC 1 550A E marked, TUV certified, CSA certified, UL 1077
50
7,500A @ 65V DC 3,000A @ 120V AC 3,000A @ 120/240V AC 3,000A @ 250V AC 65V DC 250V AC 2 1050A E marked, TUV certified, CSA certified, UL 1077
51
5,000A @ 32V DC 3,000A @ 240V AC 32V DC 240V AC 2 1050A E marked, TUV certified, CSA certified, UL 1077
51
5,000A @ 32V DC 3,000A @ 240V AC 32V DC 240V AC 2 1050A E marked, TUV certified, CSA certified, UL 1077
AC
Product
Page no. Iic Interrupting Capacity AC Nominal Voltage Amperage Leakage Trip Amps Regulatory 58
55
5,000A 120V per pole 15A 5mA UL 1077, UL 943 Class A
55
5,000A 120V per pole 30A 30mA UL 1077, UL 943 Class A, UL 1500
55
5,000A 120V per pole 30A 30mA UL 1077, UL 943 Class A, UL 1500
55
5,000A 120V per pole 50A 30mA UL 1077, UL 943 Class A, UL 1500
55
5,000A 120/240V per pole 50A 30mA UL 1077, UL 943 Class A, UL 1500
3091* (55)
5,000A 230V per pole 16A 30mA UL 1077, UL 943 Class A, UL 1500
3092* (55)
5,000A 230V per pole 32A 30mA UL 1077, UL 943 Class A, UL 1500
3093 (55)
5,000A 240V per pole 50A 30mA UL 1077, UL 943 Class A, UL 1500
* 230V AC, Typical of Europe 240V AC, For isolation transformer applications
AC
Product Style
DC
CIRCUIT PROTECTION
Page no. Iic Interrupting Capacity DC Iic Interrupting Capacity AC Vmxo Max. Voltage DC Vmxo Max. Voltage AC Poles Available Amperages Regulatory
52
10,000A @ 80V DC 5,000A @ 125V AC 5,000A @ 250V AC 80V DC 250V AC 1 5100A -
52
10,000A @ 80V DC 5,000A @ 125V AC 5,000A @ 250V AC 80V DC 250V AC 1 100A SAE J1171, UL 1500, ISO 8846
53
5,000A @ 32V DC 3,000A @ 120V AC 3,500A @ 240V AC 32V DC 240V AC 1 5100A E marked, SAE J1171, UL 1500, ISO 8846. CSA certified, UL 1077
DC
Product Style
Page no. Iic Interrupting Capacity DC Vmxo Max. Voltage DC Poles Available Amperages Regulatory
52
5,000A @ 65V DC 65V DC 2 150200A -
53
5,000A @ 48V DC 48V DC 2 150200A -
52
5,000A @ 65V DC 65V DC 3 250300A -
53
5,000A @ 48V DC 48V DC 3 250300A -
AC
Product Style
Page no. Iic Interrupting Capacity AC Vmxo Max. Voltage AC Poles Available Amperages Regulatory
52
5,000A @ 125/250V AC 5,000A @ 250V AC 250V AC 2 30100A -
53
5,000A @ 120/240V AC 5,000A @ 240V AC 240V AC 2 30100A E marked, TUV certified, CSA certified, UL 1077
53
5,000A @ 120/240V AC 5,000A @ 240V AC 240V AC 2 30100A E marked, TUV certified, CSA certified, UL 1077
52
5,000A @ 125/250V AC 5,000A @ 250V AC 250V AC 3 50100A -
53
5,000A @ 120/240V AC 5,000A @ 240V AC 240V AC 3 50100A E marked, TUV certified, CSA certified, UL 1077
53
5,000A @ 120/240V AC 5,000A @ 240V AC 240V AC 3 50100A E marked, TUV certified, CSA certified, UL 1077
59
60
SECTION INDEX
BUSBARS
MiniBus 100A Common BusBars DualBus 100A Common BusBars DualBus Plus 150A Common BusBars 150A Common BusBars MaxiBus 250A Common BusBars PowerBar Common BusBars PowerBar 600A Common BusBars 62 62 62 63 64 64 65
TERMINAL BLOCKS
Terminal Blocks Terminal Block Jumpers 65 65
CONNECTORS
Terminal Feed Through Connectors CableClams PowerPost Cable Connectors PowerPost Plus Cable Connectors Dual PowerPost Cable Connectors Connector Comparison Rotating CableCap Insulators Standard CableCap Insulators Automotive CableCap Insulators Square CableCap Insulators Stud CableCap Insulators Dual Entry PowerPost Cable Insulator 66 66 67 67 67 68 69 69 69 69 69 69
Sabre Yachts relies on Blue Sea Systems products, like BusBars, to build a trouble free electrical system aboard the Sabre 42 Salon Express.
61
AC
DC
Specifications
Ic Continuous Rating Vmxo Voltage Max. Operating Mounting Holes Bus Material 100A AC/DC* 300V AC/48V DC Accepts #10 (M5) Screws Tin-Plated Copper CDA 110/UNS C11000
Specifications
Ic Continuous Rating Vmxo Voltage Max. Operating Bus Material 100A AC/DC 300V AC/48V DC Tin-Plated Copper CDA 110/UNS C11000
Regulatory
E certified
2304
Regulatory
E Certified
2709
2701
2314 2710
2305
2702
Cover -
Terminal Screw 5 per bus #8-32 10 per bus #8-32 Cover for BusBar 2701 Cover for BusBar 2702
Mounting Holes Accept #10 (M5) Screws Accept #10 (M5) Screws
Weight lb (kg) 0.20 (0.09) 0.30 (0.14) 0.05 (0.02) 0.05 (0.02)
2315
Overall Height Approx. 0.58" (14.7mm) 1.83" 46.48mm
DC
2306*
1.83" 46.48mm
2.252" (57.20mm) 3.012" (76.50mm)
2701 2713
PN 2304 2314 2305 2315 2306 2713
0.90" 22.86mm
.41" (10.41mm)
2702
Weight lb (kg) 0.15 (0.07) 0.17 (0.08) 0.15 (0.07) 0.17 (0.08) 0.10 (0.05) 0.05 (0.02)
Specifications
0.625" 15.88mm
2304, 2314
0.57" 14.48mm 2.75" (69.85mm)
2305, 2315
Ic Continuous Rating Vmxo Voltage Max. Operating Mounting Holes Bus Material
PN 2722 2723 Terminal Screw 5 per bus #10-32 Terminal Stud 2 per bus 1 4"-20 Stud
130A AC/150A DC 300V AC/48V DC Accept #10 (M5) Screws Tin-Plated Copper CDA 110/UNS C11000
Weight lb (kg) 0.66 (0.30)
2.58" 65.53mm
1.875" (47.63mm)
0.60" 15.24mm
62
2722, 2723
AC
DC
Insert-molded stainless steel stud eliminates need for securing nut and allows high torquing for excellent electrical contact
The industry standard bus bar for positive distribution and for the
2301
Specifications
Ic Continuous Rating Vmxo Voltage Max. Operating Mounting Holes Bus Material 130A AC/150A DC 300V AC/48V DC Accepts #10 (M5) Screws Tin-Plated Copper CDA 110/UNS C11000
Regulatory E certified
2300
PN 2301 2300 2302 2312 2303 2307 2715 2716 Cover Yes Yes Yes Terminal Screw 10 #8-32 10 #8-32 20 #8-32 20 #8-32 Terminal Stud 2 1 4"-20 2 1 4"-20 2 1 4"-20 2 1 4"-20 4 1 4"-20 4 1 4"-20 Weight lb (kg) 0.34 (0.15) 0.37 (0.16) 0.53 (0.24) 0.58 (0.26) 0.35 (0.16) 0.38 (0.17) 0.07 (0.03) 0.13 (0.06)
Cover For BusBar 2301 and 2303 Cover For BusBar 2302
2302
2312 2303
1.25" 31.75mm
0.75" 19.50mm
SAFE Boats uses Blue2303,Systems BusBars aboard their vessels, including the Apostle 38. Sea 2307
0.75" 19.50mm
2300, 2301
0.624" 15.85mm
0.25" 31.75mm 7.25" (184.15mm) 8.50" (215.90mm) 9.125" (231.78mm) 1.50" 38.10mm Minimum
0.75" 19.50mm
2302, 2312 Specifications subject to change. See bluesea.com for current information.
63
AC
DC
0.75" (19mm) Typical 1.5" 38mm [B] [A] 1.7" 43mm TYP
Now with insert molded stainless steel studs and optional fully enclosed insulating base and cover
.94" 24mm
2128, 2105
250A AC/250A DC 300V AC/48V DC Accepts #10 (M5) Screws Tin-Plated Copper CDA 110 UNS C11000
1.2" (30mm) Typical 1.5" 38mm [B] [A] 1.7" 43mm TYP
.94" 24mm
2127, 2126
2128
2105
[B]
[A]
TOP - NO COVER
SIDE
PN 2105
[B] Mounting Centers in (mm) 7.125 (181.00) 7.125 (181.00) 5.41 (137.30) 5.25 (133.00) 5.25 (133.00) 4.10 (104.10)
Weight lb (kg) 0.80 (0.36) 1.00 (0.45) 0.40 (0.18) 0.75 (0.34) 0.65 (0.29) 0.50 (0.22)
2127
Cover for 2105 and 2126 4 5/16" -18 2 5/16" -18 Cover for 2127 and 2128
2126
DC
PowerBar Common BusBars
Provides compact high-amp busing with 3 8" terminal studs
2719
1.25" 31.75mm
1.875" 47.63mm
2127, 2128 2301, 2303 2701, 2702 71007115 71807189 2016100, 2017100, 2018100 2020
PNs
1.5" 38.10mm
2019
1.63" 41.30mm
Specifications
Ic Continuous Rating Vmxo Voltage Max. Operating Mounting Holes Bus Material
Amperage rating is determined by wire amperage capacity connected to the PowerBar up to 600 Amps 48V DC Accepts #10 (M5) Screws Tin-Plated Copper CDA 110/UNS C11000
See page 64 for compatible enclosure PN 2719
Insulators Included Weight lb (kg) 0.36 (0.16) 0.36 (0.16)
Regulatory
2718
E certified
PN 2019 2020 Terminal Studs 2 3 8" -16 2 3 8" -16
MaxiBuses PowerBar Common BusBar DualBus (2x) PowerPost Cable Connectors (2x) PowerPost Plus Cable Connectors (2x) Class T Fuse Block ANL Fuse Block
PNs
64
AC
DC
AC
Terminal Blocks
DC
Employs fully insulated independent terminal blocks for applications where circuits must be isolated
2404
2104
2504
2608 2107
Each screw pair is one isolated circuit Terminal Block Jumpers allow creation of common circuits Closed back design completely insulates power from the mounting surface
Specifications
2708
Specifications
Ic Continuous Rating Vmxo Voltage Max. Operating Mounting Holes Bus Material 545A AC/600A DC 300V AC/48V DC 2104Accepts 1 4" Screws 2107Accepts #10 (M5) Screws Tin-Plated Copper CDA 110 UNS C11000
Ic Continuous Rating Vmxo Voltage Max. Operating Bus Material Mounting Holes
See table below See table below Tin-Plated Brass See drawings below
0.88" 22.35mm
0.375" 9.53mm
Regulatory
E Certified
[B] [A]
0.31" 7.87mm
Drawing 1 (24022410)
0.49" 12.45mm 0.69" 17.53mm Mounting hole for #10 Screw
Regulatory
E certified
Overall Height Approx. 2.00" (50.80mm) 2.00" 50.80mm [B] [A] 1.32" 33.53mm 1.25" (31.75mm) Typical
0.56" 14.22mm 1.31" 33.27mm [B] [A] Overall Height Approx. 0.71" (18.0mm)
0.50" 12.70mm
Drawing 3 (26022610)
PN 2104 2107 2708 Terminal Studs 4 3 8" -16 8 3 8" -16 Cover For 2104 Terminal Screws 4 x #8-32 4 x #8-32 [A] Length in (mm) 7.0 (177.8) [B] Mounting Centers in (mm) 6.25 (158.74) Weight lb (kg) 1.75 (0.79) 0.25 (0.11) PN 2402 2404 2406 2408 2410 2502 2504 2506 2508 2510 2512 2602 2604 2606 2608 2610 Circuits 2 4 6 8 10 2 4 6 8 10 12 2 4 6 8 10 AC/DC Ic 20 20 20 20 20 30 30 30 30 30 30 65 65 65 65 65 AC/DC Vmxo 300 300 300 300 300 600 600 600 600 600 600 600 600 600 600 600 Terminal Drawing Screw Number #6 #6 #6 #6 #6 #8 #8 #8 #8 #8 #8 #10 #10 #10 #10 #10 1 1 1 1 1 2 2 2 2 2 2 3 3 3 3 3 [A] Length in (mm) 1.41 (35.81) 2.16 (54.86) 2.91 (73.91) 3.66 (92.96) 4.41 (112.01) 2.10 (53.34) 3.22 (87.79) 4.34 (110.24) 5.46 (138.68) 6.58 (167.13) 7.70 (195.58) 2.50 (63.49) 3.88 (98.55) 5.26 (133.61) 6.64 (168.67) 8.02 (203.73)
Drawing 2 (25022512)
[B] Mounting Centers in (mm) 1.13 (28.70) 1.88 (47.75) 2.63 (66.80) 3.38 (85.85) 4.13 (104.90) 1.69 (42.93) 2.81 (71.37) 3.93 (99.82) 5.05 (128.27) 6.17 (156.72) 7.29 (185.17) 2.06 (52.32) 3.44 (87.38) 4.82 (122.43) 6.20 (157.48) 7.58 (192.53)
Weight lb (kg) 0.05 (0.02) 0.06 (0.03) 0.08 (0.04) 0.10 (0.05) 0.11 (0.05) 0.11 (0.05) 0.15 (0.07) 0.21 (0.10) 0.27 (0.12) 0.33 (0.15) 0.35 (0.16) 0.15 (0.07) 0.25 (0.11) 0.34 (0.16) 0.43 (0.20) 0.52 (0.24)
Combines independent circuits on a terminal block (above) and ST-Blade Fuse Blocks PNs 5035 and 5037 (p. 39)
Jumpers allow creation of common circuits on independent connectors Five per retail package
Specifications
Bus Material Continuous Amperage
PN 9218 9217 9216
Description
For use with 20A Terminal Blocks 0.03 (0.01) For use with 30A Terminal Blocks 0.04 (0.02) For use with 65A Terminal Blocks 0.05 (0.03)
9218 9217 9216 Specifications subject to change. See bluesea.com for current information.
65
DC
CONNECTORS AND INSULATORS
CableClams
Eliminates chafe and provides strain relief when passing high current through hulls, decks and bulkheads
Protects large cables that are subject to chafing when passed through holes The large terminals have a mounting face that can be gasketed or bedded to provide a water tight installation
Provides a waterproof pass-through for antenna cables without requiring removal of the factory installed connector
Specifications
Vmxo Voltage Max. Operating Imxo Amperage Max. Operating Stud Material Mounting Holes 48V DC See table below Tin-Plated Copper Alloy Accepts #10 (M5) Screws
COMPRESSION RING DECK RING
SEAL
GASKET
Regulatory
Rated IP66protected against powerful water jets
Weight lb (kg) 0.30 (0.14) 0.30 (0.14) 0.30 (0.14) 0.30 (0.14)
1001
Perfect for antenna installation Save the expense of removing and replacing connectors Avoid poor connections from removing factory connectors Use 1001 for GPS antenna cables, 1002 for VHF antenna cables, 1003 for Radar antenna cables UV-Stabilized Thermoplastic UV-Stabilized Buna-N Rubber Stainless Steel
Max. Connector Diameter in (mm) 0.68 (17.0) 0.83 (21.0) 1.40 (35.0)
Mounting hole for #6 Screw 1.70" DIA. 43.18mm
Specifications
Ring Material Seal Material Fasteners
PN 1001
Max. Cable Diameter in (mm) 0.31 (8.0) 0.44 (11.0) 0.56 (14.0)
2201
1002 1003
2202
0.86" 21.84mm For mounting in 0.875" hole 2.0" 50.80mm 1.313" 33.34mm
1.25" 31.75mm
1.285" 32.64mm
22012204
Lock Washer
Mounting Diagram
66
DC
Provides a termination point for extending the length of outboard harnesses or other conductors
2010
2003
Specifications
Ic Continuous Rating: Not ratedamperage flows between terminals stacked on post and is determined by wire and terminals used. 48V DC Accepts #8 Screws (2010, 2011) Accepts 1 4" Screws (2001, 200, 2003)
2017
Regulatory
E Certified
PN 2010 2011 2001 2002 2003 Terminal Stud #10-32 5 8" 1 4"-20 3 4" 1 4"-20 1-1 16" 5 16"-18 7 8" 3 8"-16 7 8" Weight lb (kg) 0.06 (0.03) 0.10 (0.05) 0.20 (0.09) 0.25 (0.11) 0.27 (0.12)
0.832" 21.13mm 1.063" 26.99mm 1.625" 41.28mm
2.50" (63.50mm) 3.30" (83.82mm) 1.75" 44.45mm
Designed for connecting high amp conductors 2018 is also designed for outboard engine installation when factor cables need to be extended Includes insulators 4002 and 4003 (p. 69)
Specifications
Ic Continuous Rating: Not ratedamperage flows between terminals stacked on post and is determined by wire and terminals used. 48V DC Accepts #10 (M5) Screws
20012003
PNs 2001, 2002, and 2003, see page 64 for compatible enclosure PN 2718
1.25" 31.75mm
1.875" 47.63mm
2010, 2011
1.50" 38.10mm
0.75" 19.05mm
[B]
2.75" 69.85mm
1.75" 44.45mm
PN 2016 2017
Insulating Stud Height A Cover in (mm) Yes Yes Yes 1.50 (38.1) 1.50 (38.1) 1.63 (41.3) 1.63 (41.3) 1.50 (38.1)
Stud Height B in (mm) 1.50 (38.1) 1.50 (38.1) 1.63 (41.3) 1.63 (41.3) 1.63 (41.3)
Weight lb (kg) 0.27 (0.12) 0.27 (0.12) 0.27 (0.12) 0.27 (0.12) 0.27 (0.12)
2103
2017100 2 3 8"-16 Studs 2018 1 5 16"-18 Stud, 1 3 8"-16 Stud with Insulators 1 5 16"-18 Stud, 1 3 8"-16 Stud
150 Amp bus allows small wire connections at high amperage cable connections Includes insulator
Specifications
Ic Continuous Rating: Vmxo Voltage Max. Operating Mounting Holes Bus Material 150A DC 48V DC Accepts 1 4" Screws Tin-Plated Copper
Terminal Stud 1 4"-20 1" 5 16"-18 3 4" 3 8"-16 3 4" Terminal Screws 8 #8-32 8 #8-32 8 #8-32 Weight lb (kg) 0.29 (0.13) 0.30 (0.14) 0.34 (0.15)
2018100
1.50 (38.1)
1.63 (41.3)
0.27 (0.12)
Regulatory
E Certified
67
Connector Comparison
CONNECTORS AND INSULATORS
Product
MiniBus 100A Common BusBars DualBus 100A Common BusBars DualBus Plus 150A Common BusBars 150A Common BusBars
Page no.
62 130A AC 150A DC 300V AC 48V DC 5 per bus #8-32 2 per bus 1/4"-20 or 2 per bus 5/16"-18 Included
Ic Continuous Rating Vmxo Max. Voltage Terminal Screw Terminal Stud Insulating Cover
Product
Page no. Ic Continuous Rating Vmxo Max. Voltage Terminal Screw Terminal Stud Insulating Cover
Product
Terminal Blocks
Page no. Ic Continuous Rating Vmxo Max. Voltage Terminal Screw Terminal Stud Insulating Cover
67
Determined by wire and terminals
67
Determined by wire and terminals
67
Determined by wire and terminals
68
4018 4001
PN 4001 9030B 9031B Cable Size (AWG) All All All Color Red/Black Black Red Package Pair/Retail Bulk/Not for retail Bulk/Not for retail Weight lb (kg) 0.25 (0.11) 0.10 (0.05) 0.10 (0.05) PN 4018 4019B 4020B Cable Size (AWG) 1/0 1/0 1/0 Color Red/Black Red Black Package Pair/Retail Bulk/Not for retail Bulk/Not for retail Weight lb (kg) 0.19 (0.08) 0.06 (0.03) 0.06 (0.03)
Insulates single stud on alternators, starters, windlasses and high amperage termination points
4008 4005
PN 4005 4006 9038B 9039B 9040B 9041B Cable Size (AWG) 4, 2, 1 1/0, 2/0 4, 2, 1 4, 2, 1 1/0, 2/0 1/0, 2/0 Color Red/Black Red/Black Black Red Black Red Package Pair/Retail Pair/Retail Bulk/Not for retail Bulk/Not for retail Bulk/Not for retail Bulk/Not for retail Weight lb (kg) 0.22 (0.10) 0.22 (0.10) 0.07 (0.03) 0.07 (0.03) 0.07 (0.03) 0.07 (0.03) PN 4008 4009 4010 4011 4012 4013 4014 4015
4009
Cable Size (AWG) 1810 1810 84 84 22/0 22/0 3/04/0 3/04/0 Color Red Black Red Black Red Black Red Black Package Retail/3 Retail/3 Retail/2 Retail/2 Retail/1 Retail/1 Retail/1 Retail/1 Weight lb (kg) 0.05 (0.02) 0.05 (0.02) 0.05 (0.02) 0.05 (0.02) 0.07 (0.03) 0.07 (0.03) 0.07 (0.03) 0.07 (0.03)
4016
Cable Size (AWG) 4, 2, 1 1/0, 2/0 1/0, 2/0 1/0, 2/0 Weight lb (kg) 0.18 (0.08) 0.18 (0.08) 0.07 (0.03) 0.07 (0.03)
4002
4003
PowerPost Insulator
NEW
Provides electrical insulation for single studs and large cables. This insulator is included with the following part numbers; 2001, 2002, 2003, 2101, 2102, 2103, and 2019.
PN 4002 4003 Cable Size (AWG) up to 2/0 up to 2/0 Cable Entry Size 0.7" (17.8 mm) 0.7" (17.8 mm) Color Black Red Package Retail/1 Retail/1 Weight lb (kg) 0.08 (0.04) 0.08 (0.04)
PN 4004
Color Red
Package Retail
69
70
POWER DISTRIBUTION
At the heart of a boats electrical system is the power distribution panel. Blue Sea Systems manufactures panels for small runabouts to large offshore cruising yachts, with four panel styles to choose from. WeatherDeck Waterproof Panels rugged construction exceeds the demands of any wet location. Panels feature backlit labels, built-in toggle guard, and concealed mounting screws. Contura Switch Water Resistant Panels are designed to complement existing switches and controls and are an excellent addition to any cockpit, bridge, or cabin. Traditional Metal Panels are styled to match existing panels found on many boats and are often used as a replacement panel. Panels are pre-wired and ready to install right out of the box. The 360 Panel System uses an open frame and modular architecture to mount a broad selection of panel components. This allows multiple functions to be combined in a single panel for unmatched flexibility and future upgradability. Custom 360 Panels are available when a standard panel does not suffice. The online Panel Wizard provides a simple tool to design a fully customized panel that is built and shipped from our Bellingham facility within 7 business days of order receipt.
SECTION INDEX
ABOVE DECK PANELS
WeatherDeck Waterproof Contura Switch Water Resistant 7273 7475
Blue Sea Systems Custom 360 Panel easily manages the long list of electrical demands found on every Sabre Yachts 54 Salon Express.
71
DC
POWER DISTRIBUTION
Fuse Panel
72
DC
POWER DISTRIBUTION
4374
Component References
ONOFF Toggle Switch (p. 113) WeatherDeck Toggle Switch Waterproof Boots (p. 113) Push Button, Thermal Trip, Manual Reset-Only Circuit Breakers (p. 46) Push Button, Thermal Trip, Manual Reset-Only Waterproof Boots (p. 46) ATOATC Blade-Type Fuses (p. 35) Rugged UV stabilized waterproof boots (p. 113) 24 Volts DC 15A @ 12V DC (per circuit) 9A @ 24V DC (per circuit) 10mA/Illuminated Circuit 45A
4376
4378
12 or 24V DC 10mA/Illuminated Circuit 15A 12V DC 15A @ 12V DC (per circuit) 10mA/Illuminated Circuit 2 Position30A 4 Position60A 6 Position90A 8 Position100A 15A Max. 12V DC Nominal 130A
Fuse Panels
4302
4304
Regulatory
IP67protected against immersion up to 1 meter for 30 minutes
(see inside back cover)
4306
PN 4374 4376 4378 4302 4304 4306 4308 Circuit Protection Circuit Breakers Circuit Breakers Circuit Breakers Fuses Fuses Fuses Fuses Width in (mm) 4.25 (107.95) 4.25 (107.95) 4.25 (107.95) 3.88 (98.55) 3.88 (98.55) 3.88 (98.55) 3.88 (98.55) Height in (mm) 4.30 (109.22) 6.00 (152.40) 7.70 (195.58) 2.60 (66.04) 4.30 (109.22) 6.00 (152.40) 7.70 (195.58) Depth in (mm) 3.50 (88.90) 3.50 (88.90) 3.50 (88.90) 2.50 (63.50) 2.50 (63.50) 2.50 (63.50) 2.50 (63.50) Width Mounting Centers in (mm) 3.69 (93.73) 3.69 (93.73) 3.69 (93.73) 3.31 (84.07) 3.31 (84.07) 3.31 (84.07) 3.31 (84.07) Height Mounting Centers in (mm) 3.74 (95.00) 5.44 (138.18) 7.14 (181.36) 2.04 (51.82) 3.74 (95.00) 5.44 (138.18) 7.14 (181.36) Weight lb (kg) 0.97 (0.44) 1.36 (0.62) 1.83 (0.83) 0.52 (0.24) 0.90 (0.41) 1.15 (0.52) 1.55 (0.70)
4308
73
DC
POWER DISTRIBUTION
voltage rating: 12 or 24V DC total panel rating: 45A ON indication: LED in switch labels: model
circuit breaker fuse
format
small large or small
Fuse Panel
* circuit breaker model only Aluminum panel is chemically treated front and back and painted to resist corrosion
74
DC
POWER DISTRIBUTION
8374
Component References
ON-OFF Contura switches (p. 112) Push Button Reset-Only Circuit Breakers (p. 46) Water Resistant Fuse Holders (p. 38)
Specifications
Vmxo Voltage Max. Operating Ioc (Switch LED) Amperage Operating Current Switch Rating Circuit Breaker Rating Fuse Holder Rating Panel Cumulative Rating 24V DC 18 Milliamps each 20A @ 12V DC 15A @ 24V DC 15A 20A Max. (15A fuses included) 45A (all except 8 position panels) 90A (8 position panels)
8372
8373
Regulatory
E marked CIRCUIT BREAKER MODELS ONLY Meet UL 1500 and ISO 8846 external ignition protection requirements Panel front is IP66 when mounted with gasket in placeprotected against powerful water jets
(see inside back cover) 8274
8371
8271
8262
8054*
8273
8272
PN 8274 8272 8273 8271 8374 8372 8373 8371 8054* 8053* 8262 8261 8263 Push Button Circuit Breakers 3 4 6 8 3 4 6 8 AGC/MDL Fuse Holders 3 6 4 8 1 Width in (mm) 4.50 (114.30) Height in (mm) 3.75 (95.25) Depth in (mm) 3.25 (82.55) 3.25 (82.55) 3.25 (82.55) 3.25 (82.55) 3.25 (82.55) 3.25 (82.55) 3.25 (82.55) 3.25 (82.55) 3.00 (76.20) 3.00 (76.20) 3.00 (76.20) 3.00 (76.20) 3.00 (76.20) Weight lb (kg) 0.75 (0.34) 0.90 (0.41) 1.35 (0.61) 1.75 (0.79) 0.75 (0.34) 0.90 (0.41) 1.35 (0.61) 1.75 (0.79) 0.70 (0.32) 1.20 (0.54) 0.75 (0.34) 1.40 (0.64) 0.25 (0.11)
8261
5.25 (133.35) 4.25 (107.95) 4.50 (114.30) 7.50 (190.50) 9.37 (238.00) 4.25 (107.95) 4.50 (114.30) 3.75 (95.25)
5.25 (133.35) 4.25 (107.95) 4.50 (114.30) 7.50 (190.50) 9.37 (238.00) 4.25 (107.95) 5.25 (133.35) 3.75 (95.25)
5.25 (133.35) 7.50 (190.50) 5.25 (133.35) 9.37 (238.00) 2.25 (57.15) 3.75 (95.25) 3.75 (95.25) 3.75 (95.25)
8053*
* 8054 and 8053 include Large Format Label Set 8030 (p. 117120) 8263 Bilge Pump Control Panel(ON)-OFF-ON Contura Switch (p. 112)
75
AC
DC
POWER DISTRIBUTION
total panel rating: up to 100A per bus ON indication: LED labels: square format
Circuit status LEDs and backlit labels aid low-light readability Push Button Reset Only circuit breakers provide high-density, low cost circuit protectionhighdensity circuit protection
76
AC
DC
POWER DISTRIBUTION
Marine grade aluminum frame securely holds fixed panel components and is chemically treated to resist corrosion (aluminum frame not sold separately)
total panel rating: up to 100A per bus ON indication: LED labels: large format
77
DC
DC Branch panels distribute current from a high amperage input into lower amperage circuits
Features:
ON-indicating LEDs in all circuit positions Panels with voltmeters include a toggle switch to monitor voltage on up to three battery banks Backlit label positions for select models
Component References:
A-Series Circuit Breakers (p. 5051) Push Button Reset-Only Circuit Breakers (p. 46) ON-OFF, SPST Rocker Switches (p. 110) 360 Panel System includes PN 4205 label set (p. 120) Traditional Metal panels include PN 8030 label set (p. 120) DC Digital Multimeter (p. 101) DC Analog Meters (p. 98) Amber ON-indicating LEDs (p. 115)
POWER DISTRIBUTION
8025
Style Total Positions Circuit Breakers (PN) Rocker Switches (PN) Nominal Voltage Maximum Amperage Meter (PN) Width x Height in (mm) Depth in (mm) Weight lb (kg)
1216
1116*
1151
1455
1155
1459
8081
Traditional Metal
Traditional Metal
3 Positions
3 A-Series, 15A (7210) 12/24V DC 100A 5.25 (133.35) x 4.75 (120.65) 2.50 (63.50) 1.15 (0.52)
4 Positions
4 A-Series, 15A (7403) 12V DC 100A 4.88 (123.83) x 4.75 (120.65) 3.00 (76.20) 1.35 (0.61)
4 Positions
4 Push Button, 10A (7054) 4 ON-OFF, SPST (7480) 12V DC 40A 4.88 (123.83) x 4.75 (120.65) 3.50 (88.90) 1.07 (0.49)
4 Positions
4 Push Button, 10A (7054) 4 ON-OFF, SPST (7480) 12V DC 40A 816V (8003) 4.88 (123.83) x 7.75 (196.85) 3.50 (88.90) 1.4 (.64)
5 Positions
5 A-Series, 15A (7210) 12V DC 50A 816V (8028) / 050A (8041) 5.25 (133.35) x 7.50 (190.50) 2.50 (63.50) 2.25 (1.02)
8401
Style Total Positions Circuit Breakers (PN) Rocker Switches (PN) Nominal Voltage Maximum Amperage Meter (PN) Width x Height in (mm) Depth in (mm) Weight lb (kg)
8096
Traditional Metal
1450
360 Panel System
1156
1457
1154
1456
Traditional Metal
5 Positions
5 A-Series, 15A (7210) 12/24V DC 100A Digital Multimeter (8248) 5.25 (133.35) x 7.50 (190.50) 4.00 (101.6) 3.45 (1.57)
6 Positions
6 A-Series, 15A (7210) 12/24V DC 100A per bus 10.50 (266.70) x 3.75 (95.25) 2.50 (63.50) 2.25 (1.02)
8 Positions
8 Push Button, 15A (7056) 12/24V DC 90A 4.88 (123.83) x 4.75 (120.65) 3.50 (88.90) 1.21 (0.57)
8 Positions
8 Push Button, 10A (7054) 8 ON-OFF, SPST (7480) 12V DC 80A 4.88 (123.83) x 7.75 (196.85) 3.50 (88.90) 1.75 (.80)
8 Positions
8 Push Button, 10A (7054) 8 ON-OFF, SPST (7480) 12V DC 80A 9.25 (234.95) x 4.75 (120.65) 3.50 (88.90) 2.95 (1.34)
1200
Style Total Positions Circuit Breakers (PN) Rocker Switches (PN) Nominal Voltage Maximum Amperage Meter (PN) Width x Height in (mm) Depth in (mm) Weight lb (kg)
1100*
1225
1125*
8023
Traditional Metal
8385
Traditional Metal
1164
1463
8 Positions
8 A-Series, 15A (7403) 12V DC 100A 4.88 (123.83) x 7.75 (196.85) 3.00 (76.20) 2.6 (1.18)
8 Positions
8 A-Series, 15A (7403) 12V DC 100A per bus 9.25 (234.95) x 4.75 (120.65) 3.00 (76.20) 3.84 (1.75)
8 Positions
5 A-Series, 15A (7210) 12/24V DC 100A 5.25 (133.35) x 7.50 (190.50) 2.50 (63.50) 1.95 (0.89)
8 Positions
6 A-Series, 15A (7210) 12/24V DC 100A per bus 10.50 (266.70) x 4.50 (114.30) 2.50 (63.50) 2.70 (1.23)
8 Positions
8 Push Button, 10A (7054) 8 ON-OFF, SPST (7480) 12V DC 80A 816V (8003) 4.88 (123.83) x 10.75 (273.05) 3.50 (88.90) 3.72 (1.69)
78
* Black toggle style panels (not shown) Panels without backlighting (not shown)
POWER DISTRIBUTION
1227
Style Total Positions Circuit Breakers (PN) Rocker Switches (PN) Nominal Voltage Maximum Amperage Meter (PN) Width X Height in (mm) Depth in (mm) Weight lb (kg)
1127*
1224
1124*
8082
Traditional Metal
8402
Traditional Metal
1165
1461
8 Positions
8 A-Series, 15A (7403) 12V DC 100A Digital Multimeter (8248) 4.88 (123.83) x 7.75 (196.85) 3.00 (76.20) 5.76 (2.62)
8 Positions
8 A-Series, 15A (7403) 12V DC 50A 816V (8003) / 050A (8022) 9.25 (234.95) x 7.75 (196.85) 3.00 (76.20) 4.56 (2.07)
10 Positions
7 A-Series, 15A (7210) 12V DC 50A 816V (8028) / 050A (8041) 5.25 (133.35) x 11.25 (285.75) 2.50 (63.50) 3.35 (1.52)
10 Positions
7 A-Series, 15A (7210) 12/24V DC 100A Digital Multimeter (8248) 5.25 (133.35) x 11.25 (285.75) 4.00 (101.6) 4.21 (1.91)
12 Positions
12 Push Button, 10A (7054) 12 ON-OFF, SPST (7480) 12V DC 120A 4.88 (123.83) x 10.75 (273.05) 3.50 (88.90) 3.6 (1.64)
1159
Style Total Positions Circuit Breakers (PN) Rocker Switches (PN) Nominal Voltage Maximum Amperage Meter (PN) Width x Height in (mm) Depth in (mm) Weight lb (kg)
1464
1223
1123*
1217
1117*
8375
Traditional Metal
12 Positions
12 Push Button, 10A (7054) 12 ON-OFF, SPST (7480) 12V DC 120A 816V (8003) 9.25 (234.95) x 7.75 (196.85) 3.50 (88.90) 4.37 (1.99)
12 Positions
12 A-Series, 15A (7403) 12V DC 100A 4.88 (123.83) x 10.75 (273.05) 3.00 (76.20) 4.85 (2.20)
12 Positions
12 A-Series, 15A (7403) 12V DC 100A per bus Digital Multimeter (8248) 9.25 (234.95) x 7.75 (196.85) 4.00 (101.60) 5.99 (2.72)
12 Positions
10 A-Series, 15A (7210) 12/24V DC 100A per bus 14.75 (374.65) x 4.50 (114.30) 2.50 (63.50) 5.84 (2.65)
8376
Style Total Positions Circuit Breakers (PN) Nominal Voltage Maximum Amperage Meter (PN) Width x Height in (mm) Depth in (mm) Weight lb (kg)
8068
Traditional Metal
8403
Traditional Metal
Traditional Metal
13 Positions
10 A-Series, 15A (7210) 12/24V DC 100A 5.25 (133.35) x 11.25 (285.75) 2.50 (63.50) 3.1 (1.41)
13 Positions
10 A-Series, 15A (7210) 12V DC 50A 816V (8028) / 050A (8041) 10.50 (266.70) x 7.50 (190.50) 3.00 (76.20) 4.20 (1.91)
13 Positions
10 A-Series, 15A (7210) 12/24V DC 100A per bus Digital Multimeter (8248) 10.50 (266.70) x 7.50 (190.50) 4.00 (101.6) 5.15 (2.34)
* Black toggle style panels (not shown) Panels without backlighting (not shown)
79
DC
POWER DISTRIBUTION
1452
Style Total Positions Circuit Breakers (PN) Rocker Switches (PN) Nominal Voltage Maximum Amperage Width in (mm) Height in (mm) Depth in (mm) Weight
1222
360 Panel System
1122*
8377
Traditional Metal
16 Positions
16 Push Button, 15A (7056) 12/24V DC 180A 4.88 (123.83) 7.75 (196.85) 3.50 (88.90) 2.20 (1.10)
16 Positions
16 A-Series, 15A (7403) 12V DC 100A per bus 9.25 (234.95) 7.75 (196.85) 3.00 (76.20) 6.27 (2.85)
16 Positions
10 A-Series, 15A (7210) 12/24V DC 100A per bus 10.50 (266.70) 7.50 (190.50) 2.50 (63.50) 3.68 (1.67)
1201
Style Total Positions Circuit Breakers (PN) Nominal Voltage Maximum Amperage Meter (PN) Width in (mm) Height in (mm) Depth in (mm) Weight lb (kg)
1101*
360 Panel System
8378
Traditional Metal
1221
360 Panel System
16 Positions
16 A-Series, 15A (7403) 12V DC 50A 816V (8003) / 050A (8022) 13.63 (346.08) 7.75 (196.85) 3.00 (76.20) 6.58 (2.99)
18 Positions
15 A-Series, 15A (7210) 12V DC 100A 816V (8003) / 0100A (8017) 14.75 (374.65) 7.50 (190.50) 2.50 (63.50) 7.80 (3.55)
Main + 19 Positions
1 C-Series, 100A (7549) / 19 A-Series, 15A (7403) 12V DC 100A Digital Multimeter (8248) 13.63 (346.08) 7.75 (196.85) 4.00 (101.60) 8.8 (4.0)
8379
Style Total Positions Circuit Breakers (PN) Nominal Voltage Maximum Amperage Meter (PN) Width in (mm) Height in (mm) Depth in (mm) Weight lb (kg)
8380
Traditional Metal
8264
Traditional Metal
Traditional Metal
Main + 20 Positions
1 C-Series, 100A (7250I) / 14 A-Series, 15A (7210) 12/24V DC 100A Digital Multimeter (8248) 14.75 (374.65) 7.50 (190.50) 4.00 (101.6) 8.40 (3.82)
Main + 22 Positions
1 C-Series, 100A (7250I) / 16 A-Series, 15A (7210) 12V DC 100A 816V (8028) / 0100A Micro 10.50 (266.70) 11.25 (285.75) 3.00 (76.20) 8.25 (3.75)
24 Positions
15 A-Series, 15A (7210) 12/24V DC 100A per bus 14.75 (374.65) 7.50 (190.50) 2.50 (63.50) 7.45 (3.39)
80
* Black toggle style panels (not shown) Panels without backlighting (not shown)
POWER DISTRIBUTION
1226
Style Total Positions Circuit Breakers (PN) Nominal Voltage Maximum Amperage Meter (PN) Width in (mm) Height in (mm) Depth in (mm) Weight lb (kg)
8381
Traditional Metal
8382
Traditional Metal
Main + 31 Positions
1 C-Series, 100A (7549) / 31 A-Series, 15A (7403) 12V DC 100A per bus Digital Multimeter (8248) 13.63 (346.08) 10.75 (273.05) 4.00 (101.60) 14.26 (6.48)
Main + 32 Positions
1 C-Series, 100A (7250I) / 23 A-Series, 15A (7210) 12V DC 100A 816V (8003) / 0100A (8017) 14.75 (374.65) 11.25 (285.75) 3.00 (76.20) 8.60 (3.91)
Main + 35 Positions
1 C-Series, 100A (7250I) / 26 A-Series, 15A (7210) 12/24V DC 100A Digital Multimeter (8248) 14.75 (374.65) 11.25 (285.75) 4.00 (101.6) 10.80 (4.91)
SAFE Boats specifies Blue Sea Systems 360 Panels aboard their Defender boats used by military and commercial agencies.
81
AC
AC Branch panels distribute current from a high amperage input into lower amperage circuits.
Component References:
Traditional Metal panels include PN 8031 label set (p. 120) A-Series Circuit Breakers (p. 5051) Green ON-indicating LEDs (p. 115) AC Analog Meters (p. 99) 360 Panel System includes PN 4206 label set (p. 120) On indicating LEDs in all circuit positions Backlit label positions
POWER DISTRIBUTION
8058
Style Total Positions Circuit Breakers (PN) Nominal Voltage Maximum Amperage Actuator Style Insulating Back Cover Width x Height in (mm) Depth in (mm) Weight lb (kg)
8158
1210
1211
1110
1111
8097
8197
Traditional Metal
Traditional Metal
3 Positions
120V AC 100A White Toggle 4026 sold separately (p. 116) 5.25 (133.35) x 3.75 (95.25) 2.50 (63.50) 1.2 (0.55) 230V AC
4 Positions
120V AC 100A Flat Rocker 1331 sold separately (p. 110) 4.88 (123.83) x 4.75 (120.65) 3.00 (76.20) 1.57 (0.71) 230V AC
4 Positions
120V AC 100A Black Toggle 1331 sold separately (p. 110) 4.88 (123.83) x 4.75 (120.65) 3.00 (76.20) 1.5 (0.68) 230V AC
6 Positions
120V AC 100A per bus White Toggle 10.50 (266.70) x 3.75 (95.25) 2.50 (63.50) 2.22 (1.01) 230V AC
3 A-Series, 15A (7210) 3 A-Series, 8A (7299) 4 A-Series, 15A (7403) 4 A-Series, 8A (7401) 4 A-Series, 15A (7208) 4 A-Series, 8A (7347) 6 A-Series, 15A (7210) 6 A-Series, 8A (7299)
1228
Style Total Positions Circuit Breakers (PN) Nominal Voltage Maximum Amperage Actuator Style Insulating Back Cover Width x Height in (mm) Depth in (mm) Weight lb (kg) 120V AC 100A Flat Rocker
1229
360 Panel System
1128
360 Panel System
1129
8059
Traditional Metal
8159
8 Positions
8 A-Series, 15A (7403) 8 A-Series, 8A (7401) 230V AC 120V AC
8 Positions
8 A-Series, 15A (7208) 100A Black Toggle 1341 sold separately (p. 110) 4.88 (123.83) x 7.75 (196.85) 3.00 (76.20) 2.52 (1.15) 8 A-Series, 8A (7347) 230V AC 120V AC
8 Positions
5 A-Series, 15A (7210) 100A White Toggle 4027 sold separately (p. 116) 5.25 (133.35) x 7.50 (190.50) 2.50 (63.50) 2.0 (0.91) 5 A-Series, 8A (7299) 230V AC
1341 sold separately (p. 110) 4.88 (123.83) x 7.75 (196.85) 3.00 (76.20) 2.68 (1.22)
8411
Style Total Positions Circuit Breakers (PN) Nominal Voltage Maximum Amperage Actuator Style Meter (PN) Insulating Back Cover Width x Height in (mm) Depth in (mm) Weight lb (kg) 120V AC 100A per bus White Toggle -
8511
Traditional Metal
8478
Traditional Metal
8578
8480
Traditional Metal
8580
8 Positions
6 A-Series, 15A (7210) 6 A-Series, 8A (7299) 230V AC 120V AC
10 Positions
7 A-Series, 15A (7210) 100A White Toggle 0-150V (9353) 5.25 (133.35) x 11.25 (285.75) 2.50 (63.50) 3.0 (1.36) 0-250V (9354) 7 A-Series, 8A (7299) 230V AC 120V AC
13 Positions
10 A-Series, 15A (7210) 100A White Toggle 5.25 (133.35) x 11.25 (285.75) 2.50 (63.50) 2.82 (1.28) 10 A-Series, 8A (7299) 230V AC
82
POWER DISTRIBUTION
8479
Style Positions Circuit Breakers (PN) Nominal Voltage Maximum Amperage Meter (PN) Actuator Style Insulating Back Cover Width in (mm) Depth in (mm) Weight lb (kg) 0150V (9353) White Toggle -
8579
Traditional Metal
8461
Traditional Metal
8561
8265
Traditional Metal
8165
13 Positions
10 A-Series, 15A (7210) 120V AC 100A/bus 0250V (9354) 10 A-Series, 8A (7299) 230V AC
16 Positions
10 A-Series, 15A (7210) 120V AC 100A/bus White Toggle 10.50 (266.70) x 7.50 (190.50) 2.50 (63.50) 3.74 (1.7) 10 A-Series, 8A (7299) 230V AC 120V AC
24 Positions
15 A-Series, 15A (7210) 100A/bus White Toggle 14.75 (374.64) x 7.50 (190.50) 2.50 (63.50) 5.12 (2.33) 15 A-Series, 8A (7299) 230V AC
Limited space and a long list of electrical requirements made Blue Sea Systems Custom 360 Panel System the best choice for a Grand Banks 49SX owner.
83
AC
The AC Main power system provides a path for delivering power from the ships source of AC power to the AC branch distribution system. It begins at the AC power source (shore power, genset, or inverter), and ends at the AC branch circuit. See page 127 for a discussion of ABYC ELCI recommendations for AC Main circuit protection. Component References
A-Series Circuit Breakers (p. 5051) AC Analog Meters (p. 99) AC Digital Multimeter (p. 102) Red reverse polarity indication LED (p. 115) Red reverse polarity indication LED Green ON indicating LEDs Backlit label positions for select models Green ON indicating LEDs (p. 115) Traditional Metal panels include PN 8031 label set (p. 120) 360 Panel System includes PN 4206 label set (p. 120) Source Selection Label Set included with panels 8077, 8177, 8079, and 8179 (p. 120)
POWER DISTRIBUTION
8077
Style Total Positions A-Series Circuit Breakers (PN) Nominal Voltage Actuator Style Insulating Back Cover Width x Height in (mm) Depth in (mm) Weight lb (kg)
8177
8079
8179
8029
8129
1214
1215
1114
1115
Traditional Metal
Traditional Metal
Traditional Metal
Main Only
Main, 30A (7238) 120V AC 2.50 (63.50) 0.51 (0.23) Main, 16A (7294) 230V AC
Main Only
Main, 50A (7242) 120V AC 2.50 (63.50) 0.51 (0.23) Main, 32A (7295) 230V AC
Main + 1 position
Main, 30A (7238) 120V AC Main, 16A (7294) 230V AC
Main + 2 positions
Main, 30A (7414) 2 Branch, 15A (7403) 120V AC Flat Rocker 1331 sold separately (p. 110) 4.88 (123.83) x 4.75 (120.65) 3.00 (76.20) 1.58 (0.72) Main, 16A (7412) 2 Branch, 8A (7401) 230V AC
Main + 2 positions
Main, 30A (7237) 2 Branch, 15A (7208) 120V AC Black Toggle 1331 sold separately (p. 110) 4.88 (123.83) x 4.75 (120.65) 3.00 (76.20) 1.5 (0.68) Main, 16A (7348) 2 Branch, 8A (7347) 230V AC
White Toggle
White Toggle
White Toggle 4026 sold separately (p. 116) 5.25 (133.35) x 3.75 (95.25) 2.50 (63.50) 1.05 (0.48)
1206
Style Total Positions A-Series Circuit Breakers (PN) Nominal Voltage Actuator Style Meter (PN) Insulating Back Cover Width x Height in (mm) Depth in (mm) Weight lb (kg)
1207
8043
8143
8409
8509
8405
8505
Traditional Metal
Traditional Metal
Traditional Metal
Main + 2 positions
Main, 30A (7414) 2 Branch, 15A (7403) 120V AC Flat Rocker 0150V (9353) 0250V (8245) Main, 16A (7412) 2 Branch, 8A (7401) 230V AC
Main + 3 positions
Main, 30A (7238) 3 Branch, 15A (7210) 120V AC White Toggle 0150V (9353) 0250V (8245) Main, 16A (7294) 3 Branch, 8A (7299) 230V AC
Main + 3 positions
Main, 30A (7238) 3 Branch, 15A (7210) 120V AC White Toggle 0150V (8244) 050A (8246) 0250V (8245) 050A (8246) Main, 16A (7294) 3 Branch, 8A (7299) 230V AC
Main + 3 positions
Main, 30A (7238) 3 Branch, 15A (7210) 120V AC White Toggle Digital Multimeter (8247) 4027 sold separately (p. 116) 5.25 (133.35) x 7.50 (190.50) 4.00 (101.60) 2.94 (1.34) Main, 16A (7294) 3 Branch, 8A (7299) 230V AC
1341 sold separately (p. 110) 4.88 (123.83) x 7.75 (196.85) 3.00 (76.20) 2.19 (1.0)
4027 sold separately (p. 116) 5.25 (133.35) x 7.50 (190.50) 2.50 (63.50) 2.0 (0.91)
4027 sold separately (p. 116) 5.25 (133.35) x 7.50 (190.50) 3.00 (76.20) 2.2 (1.0)
8099
Style Total Positions A-Series Circuit Breakers (PN) Nominal Voltage Actuator Style Insulating Back Cover Width x Height in (mm) Depth in (mm) Weight lb (kg)
8199
8027
8127
8412
8512
1230
1233
Traditional Metal
Traditional Metal
Traditional Metal
Main + 4 positions
Main, 30A (7238) 4 Branch, 15A (7210) 120V AC White Toggle 10.50 (266.70) x 3.75 (95.25) 2.50 (63.50) 2.22 (1.01) Main, 16A (7294) 4 Branch, 8A (7299) 230V AC
Main + 6 positions
Main, 30A (7238) Main, 16A (7294) 3 Branch, 15A (7210) 3 Branch, 8A (7299) 120V AC White Toggle 4027 sold separately (p. 116) 5.25 (133.35) x 7.50 (190.50) 2.50 (63.50) 1.87 (0.85) 230V AC
Main + 6 positions
Main, 30A (7238) 4 Branch, 15A (7210) 120V AC White Toggle 10.50 (266.70) x 4.50 (114.30) 2.50 (63.50) 1.9 (0.86) Main, 16A (7294) 4 Branch, 8A (7299) 230V AC
Main + 6 positions
Main, 30A (7414) Main, 16A (7412) 6 Branch, 15A (7403) 6 Branch, 8A (7401) 120V AC Flat Rocker 2 x 1331 sold separately (p. 110) 9.25 (234.95) x 4.75 (120.65) 3.00 (76.20) 3.89 (1.77) 230V AC
84
POWER DISTRIBUTION
1202
Style Total Positions A-Series Circuit Breakers (PN) Nominal Voltage Actuator Style Meter (PN) Insulating Back Cover Width x Height in (mm) Depth in (mm) Weight lb (kg)
1203
8074
8174
8488
8588
8406
8506
Traditional Metal
Traditional Metal
Traditional Metal
Main + 6 positions
Main, 30A (7414) 6 Branch, 15A (7403) 120V AC Flat Rocker 1341 sold separately (page 110} 4.88 (123.83) x 7.75 (196.85) 3.00 (76.20) 2.7 (1.23) Main, 16A (7412) 6 Branch, 8A (7401) 230V AC
Main + 8 positions
Main, 30A (7238) 5 Branch, 15A (7210) 120V AC Main, 16A (7294) 5 Branch, 8A (7299) 230V AC
Main + 8 positions
Main, 30A (7238) 5 Branch, 15A (7210) 120V AC White Toggle 0150V (9353) 5.25 (133.35) x 11.25 (285.75) 2.50 (63.50) 3.0 (1.36) 0250V (9354) Main, 16A (7294) 5 Branch, 8A (7299) 230V AC
Main + 8 positions
Main, 30A (7238) 5 Branch, 15A (7210) 120V AC White Toggle Digital Multimeter (8247) 5.25 (133.35) x 11.25 (285.75) 4.00 (101.60) 3.18 (1.45) Main, 16A (7294) 5 Branch, 8A (7299) 230V AC
White Toggle 0150V (8244) 0250V (8245) 050A (8246) 050A (8246) 5.25 (133.35) x 11.25 (285.75) 3.00 (76.20) 3.28 (1.49)
8485
Style Total Positions A-Series Circuit Breakers (PN) Nominal Voltage Actuator Style Meter (PN) Insulating Back Cover Width x Height in (mm) Depth in (mm) Weight lb (kg)
8585
8076
Traditional Metal
8176
8407
Traditional Metal
8507
Traditional Metal
Main + 11 positions
Main, 30A (7238) 8 Branch, 15A (7210) 120V AC White Toggle 5.25 (133.35) x 11.25 (285.75) 2.50 (63.50) 2.81 (1.28) Main, 16A (7294) 8 Branch, 8A (7299) 230V AC
Main + 11 positions
Main, 30A (7238) 8 Branch, 15A (7210) 120V AC White Toggle 0150V (8244) 050A (8246) 10.50 (266.70) x 7.50 (190.50) 3.00 (76.20) 4.24 (1.93) 0250V (8245) 050A (8246) Main, 16A (7294) 8 Branch, 8A (7299) 230V AC
Main + 11 positions
Main, 30A (7238) 8 Branch, 15A (7210) 120V AC White Toggle Digital Multimeter (8247) 10.50 (266.70) x 7.50 (190.50) 4.00 (101.60) 4.78 (2.17) Main, 16A (7294) 8 - Branch, 8A (7299) 230V AC
8464
Style Total Positions A-Series Circuit Breakers (PN) Nominal Voltage Actuator Style Meter (PN) Insulating Back Cover Width x Height in (mm) Depth in (mm) Weight lb (kg)
8564
Traditional Metal
8465
Traditional Metal
8565
Main + 14 positions
Main, 30A (7238) 8 Branch, 15A (7210) 120V AC White Toggle 10.50 (266.70) x 7.50 (190.50) 2.50 (63.50) 3.74 (1.70) Main, 16A (7294) 8 Branch, 8A (7299) 230V AC
Main + 22 positions
Main, 30A (7238) 13 Branch, 15A (7210) 120V AC White Toggle 14.75 (374.65) x 7.50 (190.50) 2.50 (63.50) 5.25 (2.39) Main, 16A (7294) 13 Branch, 8A (7299) 230V AC
85
AC
Features
Component References
A-Series Circuit Breakers (p. 5051) AC Analog Meters (p. 99) AC Digital Multimeter (p. 102) Red reverse polarity indication LED (p. 115) Green ON indicating LEDs (p. 115)
POWER DISTRIBUTION
Lockout slides ensure that no two sources of AC power are connected to the circuit simultaneously Backlit label positions
Traditional Metal panels with Branch circuit breakers include PN 8031 label set (p. 120) 360 Panel System panels with Branch circuit breakers include PN 4206 label set (p. 120) All Panels include a Reverse Polarity label and a Source Selection label set (p. 120)
1208
Style Total Positions A-Series Circuit Breakers (PN) Nominal Voltage Actuator Style Insulating Back Cover Width x Height in (mm) Depth in (mm) Weight lb (kg)
1209
1231
1232
8032
8132
8061
8161
Traditional Metal
Traditional Metal
2 Sources
2 Main, 30A (7574) 120V AC Raised Rocker 1331 sold separately (p. 110) 4.88 (123.83) x 4.75 (120.65) 3.00 (76.20) 1.71 (.78) 2 Main, 16A (7572) 230V AC
2 Sources
2 Main, 50A (7577) 2 Main, 32A (7575) 120V AC Raised Rocker 1331 sold separately (p. 110) 4.88 (123.83) x 4.75 (120.65) 3.00 (76.20) 1.71 (.78) 230V AC
2 Sources
2 Main, 30A (7238) 120V AC White Toggle 4026 sold separately (p. 116) 5.25 (133.35) x 3.00 (76.20) 3.00 (76.20) 1.35 (.61) 2 Main, 16A (7294) 230V AC 120V AC
2 Sources
2 Main, 50A (7242) 2 Main, 32A (7295) 230V AC White Toggle 4026 sold separately (p. 116) 5.25 (133.35) x 3.00 (76.20) 3.00 (76.20) 1.35 (.61)
8498
Style Total Positions A-Series Circuit Breakers (PN) Nominal Voltage Actuator Style Insulating Back Cover Width x Height in (mm) Depth in (mm) Weight lb (kg)
8598
Traditional Metal
8499
Traditional Metal
8599
8467
Traditional Metal
8567
3 Sources + Transfer
2 Main, 30A (7238) 1 Main, 50A (7242) 1 Transfer, 30A (7238) 120V AC White Toggle 10.50 (266.70) x 4.50 (114.30) 3.00 (76.20) 2.20 (1.0) 2 Main, 16A (7294) 1 Main, 32A (7295) 1 Transfer, 16A (7294) 230V AC
2 Sources + 4 positions
2 Main, 30A (7238) 2 Branch, 15A (7210) 120V AC White Toggle 10.50 (266.70) x 4.50 (114.30) 3.00 (76.20) 1.9 (.86) 2 Main, 16A (7294) 2 Branch, 8A (7299) 230V AC
2 Sources + 4 positions
2 Main, 30A (7238) 2 Branch, 15A (7210) 120V AC White Toggle 4027 sold separately (p. 116) 5.25 (133.35) x 7.50 (190.50) 3.00 (76.20) 2.15 (.98) 2 Main, 16A (7294) 2 Branch, 8A (7299) 230V AC
8489
Style Total Positions A-Series Circuit Breakers (PN) Nominal Voltage Actuator Style Meter Insulating Back Cover Width x Height in (mm) Depth in (mm) Weight lb (kg) 0150V (9353) -
8589
Traditional Metal
8462
Traditional Metal
8562
8466
Traditional Metal
8566
2 Sources + 6 positions
2 Main, 30A (7238) 3 Branch, 15A (7210) 120V AC White Toggle 0250V (9354) 2 Main, 16A (7294) 3 Branch, 8A (7299) 230V AC
2 Sources + 9 positions
2 Main, 30A (7238) 6 Branch, 15A (7210) 120V AC White Toggle 0150V (9353) 10.50 (266.70) x 7.50 (190.50) 3.00 (76.20) 3.8 (1.73) 0250V (9354) 2 Main, 16A (7294) 6 Branch, 8A (7299) 230V AC
2 Sources + 9 positions
2 Main, 30A (7238) 6 Branch, 15A (7210) 120V AC White Toggle 5.25 (133.35) x 11.25 (285.75) 3.00 (76.20) 2.81 (1.28) 2 Main, 16A (7294) 6 Branch, 8A (7299) 230V AC
86
POWER DISTRIBUTION
8475
Style Total Positions A-Series Circuit Breakers (PN) Nominal Voltage Actuator Style Insulating Back Cover Meter (PN) Width x Height in (mm) Depth in (mm) Weight lb (kg) 2 Main, 30A (7238) 11 Branch, 15A (7210) 120V AC White Toggle Digital Multimeter (8247) 14.75 (374.65) x 7.50 (190.50) 4.00 (101.60) 6.3 (2.86)
8575
Traditional Metal
8458
Traditional Metal
2 Sources + 17 positions
2 Main, 16A (7294) 11 Branch, 8A (7299) 230V AC
8496
Style Total Positions A-Series Circuit Breakers (PN) Nominal Voltage Actuator Style Meter (PN) Insulating Back Cover Width x Height in (mm) Depth in (mm) Weight lb (kg)
8596
Traditional Metal
Ranger Tugs uses Blue Sea Systems Traditional Metal Panels aboard their vessels including the R-29.
87
AC
POWER DISTRIBUTION
230V
Line (Hot)
Load
E marked
UL listed
9009
Style Voltage Maximum Operating Wire Size Range Insulating Panel Back Width x Height in (mm) Depth in (mm) Weight lb (kg)
1481
360 Panel System
120V AC 1410 AWG 1331 sold separately (p. 110) 4.88 (123.83) x 4.75 (120.65) 1.91 (48.51) 1.15 (.52)
1484
360 Panel System
230V AC 1410 AWG 1331 sold separately (p. 110) 4.88 (123.83) x 4.75 (120.65) 1.91 (48.51) 1.20 (0.54)
Source 1 (ex. SHORE)
120V or 230V
8367
Traditional Metal
120V AC 1410 AWG 4026 sold separately (p. 116) 5.25 (133.35) x 3.75 (95.25) 1.91 (48.51) .65 (.30)
Neutral Line (Hot) Line (Hot) Neutral 3 1 7 5
8359
Traditional Metal
230V AC 1410 AWG 4026 sold separately (p. 116) 5.25 (133.35) x 3.75 (95.25) 1.91 (48.51) .65 (.30)
Source 2 (ex. GEN)
120V or 230V
Rotar y Switch
600V AC 1410 AWG 1.89 (48.00) x 1.89 (48.00) 1.91 (48.51) .70 (.32)
Load
PN 9011 Regulatory
E marked
UL listed
9011
Style Voltage Maximum Operating Wire Size Range Insulating Panel Back Width x Height in (mm) Depth in (mm) Weight lb (kg)
1483
360 Panel System
120V AC 126 AWG 1331 sold separately (p. 110) 4.88 (123.83) x 4.75 (120.65) 2.41 (61.21) 1.64 (.75)
1486
360 Panel System
230V AC 126 AWG 1331 sold separately (p. 110) 4.88 (123.83) x 4.75 (120.65) 2.41 (61.21) 1.64 (.75)
Source 2 (ex. SHORE 2)
120V or 230V Neutral Line (Hot) Neutral Line (Hot)
8365
Traditional Metal
120V AC 126 AWG 4026 sold separately (p. 116) 5.25 (133.35) x 3.75 (95.25) 2.41 (61.21) 1.25 (.52)
8357
Traditional Metal
230V AC 126 AWG 4026 sold separately (p. 116) 5.25 (133.35) x 3.75 (95.25) 2.41 (61.21) 1.25 (.57)
Rotar y Switch
600V AC 126 AWG 2.52 (64.00) x 2.52 (64.00) 2.41 (61.21) 1.25 (.57)
11
10
Load
PN 9010 Regulatory
E marked
UL listed
9010
Style Voltage Maximum Operating Wire Size Range Insulating Panel Back Width x Height in (mm) Depth in (mm) Weight lb (kg)
1482
360 Panel System
120V AC 1410 AWG 1331 sold separately (p. 110) 4.88 (123.83) x 4.75 (120.65) 2.41 (61.21) 1.25 (0.57)
1485
360 Panel System
230V AC 1410 AWG 1331 sold separately (p. 110) 4.88 (123.83) x 4.75 (120.65) 2.41 (61.21) 1.25 (0.57)
8366
Traditional Metal
120V AC 1410 AWG 4026 sold separately (p. 116) 5.25 (133.35) x 3.75 (95.25) 2.41 (61.21) .70 (.32)
8358
Traditional Metal
230V AC 1410 AWG 4026 sold separately (p. 116) 5.25 (133.35) x 3.75 (95.25) 2.41 (61.21) .70 (.32)
Rotar y Switch
600V AC 1410 AWG 1.89 (48.00) x 1.89 (48.00) 2.41 (61.21) .70 (.32)
88
PN 9019 Regulatory
E marked
UL listed
POWER DISTRIBUTION
9019
Source 2 (ex. GEN)
120/240V
1487
360 Panel System
240V AC 126 AWG 3.65 (92.71) 3.10 (1.41)
8363
Traditional Metal
240V AC 126 AWG 3.65 (92.71) 1.41 (.64)
Style Voltage Maximum Operating Wire Size Range Insulating Panel Back Width x Height in (mm) Depth in (mm)
Rotary Switch
600V AC 126 AWG 3.65 (92.71) 1.41 (.64)
10
12 Neutral
2.52 (64.00) x 2.52 (64.00) 4.88 (123.83) x 4.75 (120.65) 5.25 (133.35) x 3.75 (95.25)
Load
120/240V
Weight lb (kg)
PN 6337 Regulatory
E marked
UL listed
6337 1489
360 Panel System
240V AC 1410 AWG 1331 sold separately (p. 110) 2.98 (75.69) 1.20 (0.54)
8386
Traditional Metal
240V AC 1410 AWG 2.98 (75.69) .76 (.35)
Style Voltage Maximum Operating Wire Size Range Insulating Panel Back Width x Height in (mm)
Rotary Switch
600V AC 1410 AWG 2.98 (75.69) .76 (.35)
10
12
14
1.89 (48.00) x 1.89 (48.00) 4.88 (123.83) x 4.75 (120.65) 5.25 (133.35) x 3.75 (95.25)
Load 1
120V 120V
Load 2
E marked
UL listed
Source 1 (ex. SHORE 1)
120V Neutral Line (Hot) Line 2 (Hot) Neutral Line (Hot) 3 1 7 5 11 9 15 13 Neutral Line 1 (Hot)
9093
Source 3 (ex. GEN)
120/240V
1480
360 Panel System
240V AC 126 AWG 4.50 (114.30) 3.50 (1.59)
8369
Traditional Metal
240V AC 126 AWG 4.50 (114.30) 1.41 (.64)
Style Voltage Maximum Operating Wire Size Range Insulating Panel Back Width x Height in (mm)
Rotary Switch
600V AC 126 AWG 4.50 (114.30) 1.41 (.64)
10
12
14
2.52 (64.00) x 2.52 (64.00) 4.88 (123.83) x 4.75 (120.65) 5.25 (133.35) x 3.75 (95.25)
Load 1
120V 120V
Load 2
E marked
UL listed
Source 2 (ex. SHORE 2)
120/240V Line 2 (Hot) Neutral Line 1 (Hot) Line 2 (Hot) Neutral Line 1 (Hot) 1 5 9 3 7 11 13 17 15 Line 1 (Hot) Neutral Line 2 (Hot)
9077
Source 3 (ex. GEN)
120/240V
1488
360 Panel System
240V AC 126 AWG 5.50 (139.70) 2.65 (1.20)
8361
Traditional Metal
240V AC 126 AWG 5.50 (139.70) 2.0 (.91)
Style Voltage Maximum Operating Wire Size Range Insulating Panel Back Width x Height in (mm) Depth in (mm)
Rotary Switch
600V AC 126 AWG 2.52 (64.0) x 2.52 (64.0) 5.50 (139.70) 2.0 (.91)
10
12
14
16
18
Load
120/240V
Weight lb (kg)
89
AC
Reduces the risk of fire and shock hazards caused by defects in boat appliances and circuit wiring. See page 54 for a review of new ABYC ELCI Features
POWER DISTRIBUTION
Component References
GFCI Branch and ELCI Main Circuit Breakers (p. 55) A-Series Circuit Breakers (p. 5051) Analog Meters (p. 99)
1500
Style Total Positions Circuit Breaker (PN) A-Series Circuit Breaker (PN) Amperage Trip Reference Leakage Trip Amperage Maximum Voltage Actuator Style Insulating Panel Back Meter (PN) Width x Height in (mm) Depth in (mm) Weight lb (kg)
1502
360 Panel System
8100
Traditional Metal
1190
360 Panel System
8101
Traditional Metal
1191
360 Panel System
ELCI
1 - ELCI Main, 30A AC (3106) 30A AC 30mA 120V AC White Toggle 5.25 (133.35) x 3.75 (95.25) 3.50 (88.90) 1.65 (.75)
8102
Style Total Positions Circuit Breaker (PN) A-Series Circuit Breaker (PN) Amperage Trip Reference Leakage Trip Amperage Maximum Voltage Actuator Style Insulating Panel Back Meter (PN) Width x Height in (mm) Depth in (mm) Weight lb (kg)
1193
360 Panel System
1192
360 Panel System
1194 AC/DC
360 Panel System
Traditional Metal
ELCI + 2 positions
1 - ELCI Main, 30A AC (3106) 2 - Branch, 15A AC (7210) 30A AC 30mA 120V AC White Toggle 0150V AC (9353) 5.25 (133.35) x 7.50 (190.50) 3.50 (88.9) 3.07 (1.4)
ELCI + 5 positions
1 - ELCI Main, 30A AC (3102) 4 - Branch, 15A AC (7403) 30A AC 30mA 120V AC Flat Rocker 2 x 1331 sold separately (p. 110) 9.25 (234.95) x 4.75 (120.65) 3.99 (101.4) 4.36 (2.0)
30A AC ELCI 30mA 120V AC/12V DC Flat Rocker 1x 1331 and 1 x 1341 sold separately (p. 110) 816V DC (8003), 0100A DC (8017) / 0150V AC (9353) 13.63 (346.08) x 10.75 (273.05) 3.99 (101.4) 12.27 (5.6)
90
AC
Provides both source selection* and circuit protection for boats with 240 Volt AC systems
POWER DISTRIBUTION
Component References
C-Series Raised Rocker Circuit Breakerstriple-pole (p. 53) C-Series Flat Rocker Circuit Breakerstriple-pole (p. 53) C-Series Toggle Circuit Breakers (p. 52)
* Source selection available for panels 1171 and 1172 only
7372
Style Total Positions C-Series Circuit Breakers (PN) Poles Nominal Voltage Maximum Voltage Actuator Style Meter (PN) Width in (mm) Height in (mm Depth in (mm) Weight lb (kg)
1168
360 Panel System
1169
360 Panel System
1170
360 Panel System
1171
360 Panel System
1172
360 Panel System
Traditional Metal
Main Only
1 Main, 50A (7287) 3 120/240V AC 240V AC White Toggle 5.25 (133.35) ) 3.75 (95.25) 3.00 (76.20) 1.38 (.63)
Main + 1 Position
1 Main, 50A (7565) 3 120/240V AC 240V AC Flat Rocker 4.88 (123.83) 4.75 (120.65) 3.00 (76.20) 1.8 (.82)
2 Sources + 2 positions
2 Main, 50A (7585) 3 120/240V AC 240V AC Raised Rocker 0-250V AC (1057) 4.88 (123.83) 13.75 (349.25) 3.00 (76.20) 7.2 (3.27)
2 Sources + 2 positions
2 - Main, 50A (7585) 3 120/240V AC 240V AC Raised Rocker AC Digital Multimeter (8247) 4.88 (123.83) 13.75 (349.25) 4.00 (101.60) 7.65 (3.48)
Back Cove Yachts chose the Blue Sea Systems 360 Panels to use on their 37 to safely switch and monitor multiple AC sources.
91
AC
DC
Combines AC and DC switching, circuit protection, source selection and monitoring into a single panel Component References:
360 Panel System AC Insulating Rear Covers (p. 110) Traditional Metal Panel AC insulating Rear Covers (p. 116) Traditional Metal panels include PN 8031 and PN 8030 label set (p. 120) 360 Panel System panels PN 4206 and PN 4205 label set (p. 120) ON indicating LEDs installed in all circuit positions A-Series Circuit Breakers (p. 5051) C-Series Circuit Breakers (p. 5253) Backlit label positions Includes toggle switch to monitor voltage on up to three batteries DC and AC Analog Meters (p. 9899) DC and AC Digital Multimeters (p. 101102) Circuit identification label sets included Insulating covers are included with 360 Panel System AC/DC panels
POWER DISTRIBUTION
1204
Style Total AC Positions Total DC Positions AC Circuit Breakers (PN) DC Circuit Breakers (PN) AC/DC Voltage Insulating Panel Back Actuator Style AC Meters (PN) DC Meters (PN) Width x Height in (mm) Depth in (mm) Weight lb (kg) 0150V AC (9353)
1205
360 Panel System
8084
Traditional Metal
8184
816V DC (8003), 0-100A DC (8017) 13.63 (346.08) x 10.75 (273.05) 4.00 (101.60) 11.67 (5.30)
8095
Style Total AC Positions Total DC Positions AC Circuit Breakers (PN) DC Circuit Breakers (PN) AC/DC Voltage Insulating Panel Back Actuator Style AC Meters (PN) DC Meters (PN) Width x Height in (mm) Depth in (mm) Weight lb (kg) 0150V AC (9353), 050A AC (9630)
8195
Traditional Metal
1218
360 Panel System
1219
92
POWER DISTRIBUTION
1118
Style Total AC Positions Total DC Positions AC Circuit Breakers (PN) DC Circuit Breakers (PN) AC/DC Voltage Insulating Panel Back Actuator Style AC Meters (PN) DC Meters (PN) Width x Height in (mm) Depth in (mm) Weight lb (kg)
1119
360 Panel System
8408
Traditional Metal
8508
8085
Style Total AC Positions Total DC Positions AC Circuit Breakers (PN) DC Circuit Breakers (PN) AC/DC Voltage Insulating Panel Back Actuator Style AC Meters (PN) DC Meters (PN) Width x Height in (mm) Depth in (mm) Weight lb (kg) 0150V AC (9353), 050A AC (9630)
8185
Traditional Metal
8086
Traditional Metal
8186
816V DC (8003) 14.75 (374.65) x 10.00 (254.00) 3.00 (76.20) 9.00 (4.09)
93
AC
DC
2.
2.
3.
20005
Blue Sea Systems labels are made using a scratch resistant polycarbonate material and are back-printed for durability. Custom Labels for the 360 Panel System can be ordered in any language and are available directly from Blue Sea Systems along with over 500 standard or square format labels.
You Can Do It, Design and Order a Custom 360 Panel Guide (20 guides per pack)
See page 128 for other You Can Do It Guides and marketing materials
94
POWER DISTRIBUTION
4.75" (120.65mm)
3x1 4x1
4.88" (123.83mm)
5x1
1 x 1 Panel
Battery Management
4 x 3 Panel
1 x 4 Panel 2 x 4 Panel
Bilge Pump
DIN Meter
Digital Meter
NEW
Sockets
2 Inch Gauge
Blank Module
95
96
METERING
Monitoring onboard systems is critical to safety and peace of mind. Running low on fuel or not knowing about a failing battery can lead to dangerous situations. Blue Sea Systems offers analog meters, digital meters, a portable multimeter, Vessel Systems Monitor, and a new P-Series Amp Hour Meter. The Vessel Systems Monitor VSM 422 represents the best in comprehensive, cost-effective monitoring. The VSM is four meters in one unit and monitors DC systems, AC systems, up to three tanks, and bilge pump operation. Its ability to perform complicated battery state-ofcharge and amp-hours-remaining calculations take the guesswork out of battery status. If the primary need is for a State of Charge (SOC) meter, Blue Sea Systems now offers the P-Series Amp Hour Meter. The large bright screen provides the information and alarms needed to manage battery systems while away from the dock.
SECTION INDEX
DC Analog Meters DC Analog Voltmeter Panels AC Analog Meters DC DIN Meters AC DIN Meters DC Digital Meters DC Digital Voltmeter Panels AC Digital Meters Mini Clamp Multimeter DC Shunts AC Current Transformers Vessel Systems Monitor VSM 422 VSM 422 Ultrasonic Tank Senders VSM 422 Battery Temperature Sensor P-Series State of Charge Meter Meter Comparison 2 Inch Round Gauges Gauge Panels 98 98 99 100 100 101 101 102 103 103 103 104 105 105 105 106 107 107
Tartan Yachts installs Blue Sea Systems 360 Panels with digital meters aboard the award winning Tartan 4000.
97
DC
Analog Meters
Micro and Standard size meters with backlighting for low light conditions
Includes appropriate external DC shunt (p. 103), Backlit meter face (separate 12 or 24V DC backlight connections)
Specifications
METERING
Amperage Operating Current 1 mA at full scale Amperage Operating Current 16 mA @ 12V DC, 20 mA @ 24V DC
Ammeters
Connection: 2 wire inline, 3 connections for backlight 8005 Function Shunt Type Meter Face Size Weight 0-25A DC Internal 2-3/4" 0.60 lb (0.27 kg)
Connection: 2 wire from shunt, 3 connections for backlight 8022 Function Shunt Type Meter Face Size Weight 0-50A DC External50 mV at meter full scale 2-3/4" 0.60 lb (0.27 kg) 0-100A DC External50 mV at meter full scale 2-3/4" 0.60 lb (0.27 kg) 0-150A DC External50 mV at meter full scale 2-3/4" 0.60 lb (0.27 kg) 0-200A DC External50 mV at meter full scale 2-3/4" 0.60 lb (0.27 kg)
Micro Ammeters
Connection: 2 wire, 3 connections for backlight 8038 Function Shunt Type Meter Face Size Weight 8041 Function Shunt Type Meter Face Size Weight 0-15A DC Internal 2" 0.20 lb (0.09 kg)
8017 Function Shunt Type Meter Face Size Weight 8018 Function Shunt Type Meter Face Size Weight 8019 Function Shunt Type Meter Face Size Weight
Connection: 2 wire from shunt, 3 connections for backlight 0-50A DC External - 50 mV at meter full scale 2" 0.40 lb (0.18 kg)
Micro Voltmeters
Connection: 2 wire, 3 connections for backlight 8028 Function Meter Face Size Weight 8243 Function Meter Face Size Weight 8-16V DC 2" 0.19 lb (0.09 kg) 18-32V DC 2" 0.19 lb (0.09 kg) 8015 Traditional Metal Width 5.25 in (133.35 mm) Height 3.75 in (95.25 mm) Weight 0.49 lb (0.22 kg)
Voltmeters
Connection: 2 wire, 3 connections for backlight 8003 Function Meter Face Size Weight 8240 Function Meter Face Size Weight 816V DC 2-3/4" 0.25 lb (0.11 kg) 1832V DC 2-3/4" 0.25 lb (0.11 kg)
1473 360 Panel System Width 4.88 in (123.83 mm) Height 4.75 in (120.65 mm) Weight 1.30 lb (0.59 kg)
98
Analog Meters
AC
Standard and Micro size meters with backlighting for low light conditions
Includes appropriate external AC Current Transformer (p. 103), when required Backlit meter face (separate 12V or 24V DC backlight connections)
Specifications
Ioc (Meter) Amperage Operating Current 50 mA AC at full scale (Ammeter only) Ioc (Backlight) Amperage Operating Current 16 mA @ 12V DC 20 mA @ 24V DC
2.375" 60.33mm 2.625" 66.68mm
8244
8246
METERING
1.26" 32.00mm
8245
Standard Meter
1.86" 47.24mm
1.055" 26.80mm
Micro Meter
0.105" 2.67mm 0.625" MAX. 15.88mm
9353
0.125" (3.18mm)
9630
Voltmeter 0150V AC
Connection 2 wire to AC hot and neutral 3 connections for backlight Meter Face Size 2-3/4" Weight 0.25 lb (0.11 kg)
Ammeter 050A AC
Connection 2 wire from coil slipped over wire to be measured 3 connections for backlight Meter Face Size 2-3/4" Weight: 0.30 lb (0.14 kg)
Screw
Surface Mount
Panel Mount
9354
Voltmeter 0250V AC
Connection 2 wire to AC hot and neutral 3 connections for backlight Meter Face Size 2-3/4" Weight 0.26 lb (0.12 kg)
8258
Ammeter 0100A AC
Connection 2 wire from coil slipped over wire to be measured 3 connections for backlight Meter Face Size 2-3/4" Weight 0.32 lb (0.15 kg)
99
DC
DIN Meters
Common Features
DIN Meters
Common Features
AC
METERING
1052
Specifications
Ioc (Meter) Amperage Operating Current 1 mA at full scale Ioc (Backlight) Amperage Operating Current 16 mA @ 12V DC 20 mA @ 24V DC
Specifications
Ioc (Meter) Amperage Operating Current 50 mA AC at full scale (Ammeter only) Ioc (Backlight) Amperage Operating Current 16 mA @ 12V DC 20 mA @ 24V DC
1053
1050
1056
1054
1051
2.835" 72.00mm 2.835" 72.00mm 1.456" 37.00mm 0.236" 6.00mm 0.551" 14.00mm 0.787" 20.00mm
1057
2.598" 66.00mm
TERMINAL COVER
1055
Description Voltmeter 016V Voltmeter 1832V Ammeter 025A Ammeter 050A Ammeter 0100A Ammeter 0150A
Connection 2 wire to DC positive (+) and negative (-) 2 wire to DC positive (+) and negative (-) 2 wire inline no other power required 2 wire from shunt no other power required 2 wire from shunt no other power required 2 wire from shunt no other power required
Shunt type Internal External 50 mV at full scale External 50 mV at full scale External 50 mV at full scale
1058
0.33 (0.15) 0.33 (0.15) 0.53 (0.24) 0.53 (0.24) 0.53 (0.24) PN Description Connection 2 wire to AC hot and neutral 2 wire to AC hot and neutral Weight lb (kg) .33 (0.15) .33 (0.15)
100
DC
Digital Meters
Specifications:
Display Character Size Power Supply Voltage Max. Power Consumption Min. Power Consumption
METERING
8248
DC Ammeter
Current Measurement: Shunt Range Resolution (-100 to -500) Resolution (-99.9 to +500) Accuracy (% of Reading) 500A/50mV 500A DC 1A DC 0.1A DC 0.5%**
Plug (if required) 3.375" (85.73mm)
Includes 8235 DC Digital Voltmeter 4 digit LED displayDisplays voltage from 060 Volts DC 3 position switch for multiple battery banks
2.431" (61.75mm)
8235
DC Voltmeter
Voltage Measurement: Range Resolution Accuracy (% of Reading) 0-60V DC 0.01V DC 0.5%**
0.226" (5.74mm)
Audio/Visual Alarms High and low voltage High and low voltage High and low voltage
Included Shunt 500A PN 8255 (p. 103) 500A PN 8255 (p. 103)
Weight lb (kg) 1.12 (0.51) 0.45 (0.20) 0.45 (0.20) 1.11 (0.50)
8051 1474
* Variable with voltage, display intensity, segments illuminated, and sleep mode ** 1 least digit of resolution
101
Digital Meters
AC
AC
DC
Specifications
METERING
Display Character Size Input Voltage Maximum Power Consumption Standby Power
8238
AC Ammeter
Current Measurement Current Transformer Range 1 (Resolution 0.01A) Range 2 (Resolution 0.1A) Accuracy (% of Reading)
8013 (meter not included) Accepts (1) 2-3/4" Analog or Digital Meter
PN Width in (mm) Height in (mm) 3.75 (95.25) Weight lb (kg) 0.25 (0.11)
8239
8237
AC Frequency Meter
Frequency Measurement Range Resolution Accuracy (% of Reading) Calibrated with sine wave input 40-90Hz 0.1Hz 0.1%***
AC Voltmeter
Voltage Measurement: Range Resolution Accuracy (% of Reading) 90-249V AC (RMS) 70-90V AC (RMS) 80-249V AC* 0.1V AC 1.0%*** 5.0%***
Weight lb (kg) 0.78 (0.35) 0.72 (0.35) 0.78 (0.35) 0.72 (0.35)
1475 (meter not included) Accepts (1) 2-3/4" Analog or Digital Meter
PN Width in (mm) Height in (mm) Weight lb (kg)
* For 120 & 240 Volt AC single phase systems ** Variable with voltage, display intensity, segments illuminated, and sleep mode *** 1 least digit of resolution
102
DC
DC Shunts
AC Current Transformers
Specifications
Dimensions 0.60 in (15.24 mm) Inside Diameter 1.38 in (35.05 mm) Outside Diameter
AC
AC
DC
Compact and feature-rich AC/DC Multimeter eases diagnosis of marine electrical problems
Clamp allows measurement of AC and DC current in wires without disturbing the circuits or contacting live terminals Compact size allows comfortable one hand operation, portability, and access to confined areas Auto range simplifies operation by automatically selecting the range that best fits the data Additional functions include: Data Hold, Overload Display, and Auto Power-Off True RMS AC measurement is accurate for normal sine wave and modified sine wave inverter output
Specifications
Shunt Type Full Scale Imxo Amperage Max. Operating I300 Amperage Int. Rating (5 min.) I3 Amperage Int. Rating (3 sec.) Resistive 50 mV 66% of Rated Current 100%Full scale rating 300%Full scale rating 8073 (shown) Analog Ammeter Transformer Ratio 50A AC/50mA AC Weight 0.10 lb (0.05 kg) 9228 8257 Analog Ammeter Transformer Ratio 100A AC/50mA AC Weight 0.20 lb (0.09 kg) 8256 Digital Ammeter Transformer Ratio 150A AC/50mA AC Weight 0.20 lb (0.09 kg) 9233
METERING
Specifications
AC Amperes (Current) AC Voltage DC Amperes (Current) DC Voltage Resistance/Continuity Alarm Measurement Resolution 0.01400 Amps 0.001600 Volts 0.01400 Amps 0.001600 Volts 0.140M 4300 counts
Regulatory
Ratio Weight lb (kg) 0.10 (0.05) 0.20 (0.09) 0.20 (0.09)
8255
PN 9228 9230 9233 8255 For Use With Analog Ammeter Analog Ammeter Analog Ammeter Digital Ammeter
1.26" (32.00mm) 0.874" (22.20mm) 2.01" (51.0mm) 0.768" (19.5mm) M6 Stud (1/4")
Weight lb (kg) 0.20 (0.09) 0.20 (0.09) 0.71 (0.32) 0.71 (0.32)
1.00" (25.40mm)
1.528" (38.80mm)
0.551" (14.00mm)
M4 Screw (#8)
9228, 9231
1.496" (38.00mm) 1.772" (45.00mm)
1.26" (32.00mm)
0.571" (14.50mm)
M4 Screw (#8)
1.693" (43.00mm)
The bright LED display on Blue Sea Systems digital meter is easy to read and is integrated in the custom 360 Panel installed aboard the Tartan 4000.
Specifications subject to change. See bluesea.com for current information.
9233, 8255
103
AC
DC
VSM 422
TM
METERING
head unit, surface mount bezel, surface mount gasket, DC Current Shunt 8255, AC Current Transformer 8256, Battery Temperature Sensor 1820, connectors, mounting screws and screw driver
DC Specifications
Nominal System Voltage Operating Voltage Minimum Current Draw Voltage Accuracy Current Range Current Accuracy 12 or 24V 8.533.0V 35mA @ 12V, backlight off 18.8mA @ 24V, backlight off +/- 0.5% 0-500A +/- 1.0% 120V @ 60Hz, North America 230V @ 50Hz, Typical of Europe 0-300V +/- 0.5% 0-150A +/- 2.0% 40-90Hz
PN 1800 1801
AC Specifications
Nominal System Voltage Operating Voltage Voltage Accuracy (RMS) Current Range Current Accuracy (RMS) Frequency
1800 1801
Regulatory
E Marked for E60945 electromagnetic interference Unit face is IP67protected against immersion up to 1 meter for 30 minutes
(see inside back cover)
VSM 422 Surface Mount Gasket creates a waterproof seal on unit face
Front Panel
Rear Panel
3.00" (76.20mm)
4.05" (102.87mm)
Front
1.235" (31.37mm)
Right
1.132" (28.75mm)
104
NEW
Amp hours or State of Charge (SOC) is often called the fuel gauge for a battery. SOC is very different from simply measuring the voltage of a battery. Voltage is only a good indicator of SOC when the battery is not being charged or discharged, and has not been active for many hours. The calculation for Amp hours uses voltage, current, temperature, and charge and discharge cycles of the battery to provide Amp Hours Remaining or Time Remaining. These values are more accurate and actionable than voltage alone. A flexible case design provides three easy mounting options: surface, rear panel, or 360 Panel System. Functions Monitored with Ranges:
DC voltage for up to three battery banks, amperage, House battery state of chargeamp hours remaining, time remaining, % charge, battery temperature
METERING
32" Diesel/Water/Waste tank sender for exclusive use with VSM 422
For tanks up to 32" deep Anti-slosh algorithms for accurate readings Ignition protected 1810
Amp Hours:
PN 1811 1810 Vmxo Voltage Max. Operating 32V DC 32V DC Weight lb (kg) 0.25 (0.11) 0.25 (0.11)
monitors amperage, amp hours remaining, time remaining, % charge, battery temperature. Monitors 0-500A DC +/- 1.0% Volts: system voltage: 12 or 24V DC (8.533V), measures 0300V +/ 0.5% Draw: minimum 10mA Includes: DC Shunt
0.89" 23mm
1.48" 38mm
0.13" 3mm
1811 Dimensions
2.72" 69mm 1.78" 45mm
0.89" 23mm
1.48" 38mm
1.58" 40mm
7518
11.00"0.25" 2796.4mm GASKET 0.10" 3mm
1.49" 38mm
Regulatory
E marked for ignition protection and electro-magnetic interference
1810 Dimensions
PN 7518
PN 1820
1820
Specifications subject to change. See bluesea.com for current information.
105
DC
Style
Meter Comparison
DC Voltmeters
DIN Analog Standard Analog Micro
DC Ammeters
Digital with or without Alarm DIN
Part Number
1050
1051
8003
8240
8028
8243
8235
8251*
1052 0-25A DC
1053
1054
1055 0-150A DC
METERING
DC Ammeters
Style Analog Standard Analog Micro Zero Center Standard Zero Center Micro Digital
DC Multimeter
Multimeter with Alarm
8005 0-25A
8022
8017
8018
8019
8038
8041
8252
8253
8254
0-50A 0-100A 0-150A 0-200A 2.80" (71.12) 2.375" (60.33) 1.96" (49.66)
0-15A DC 0-50A DC 50-0-50A DC 100-0-100A DC 50-0-50A DC 2.0" (50.80) 2.80" (71.12) 2.0" (50.80) 2.0" (50.80) 2.375" (60.33) 2.0" (50.80) 1.79" (45.47) 1.96" (49.66) 1.79" (45.47)
AC
Style
AC Voltmeters
DIN Analog Standard Analog Micro Digital
1057 0-250V AC
9353
9354
8244
8245
8246
AC Ammeters
Style DIN Analog Standard Digital
AC Frequency
AC Frequency
AC Multimeter
Multimeter with Alarm
9630 0-50A AC
8258 0-100A AC
8247* 80-249V , 0-150A, 40-90Hz, 0-9990W 2.896" (73.56) 2.431" (61.75) 3.375" (85.73)
AC
Style
DC
Multimeters
Mini Clamp Multimeter
DC
1800 - 1801 0-150V AC, 0-500A DC, Bilge, Tank 4.00" (102.87) 3.00" (76.20) 2.00" (50.87)
8110 0.01-400A AC, 0.001-600V AC, 0.01-400A DC, 0.001-600V DC 2.79" (71.00) 7.48" (190.00) -
7518 8.5-33V DC, +/-500A DC, Amp Hours 4.50" (114.03) 3.00" (76.20) 2.00" (50.87)
106
DC
Provides monitoring of key functions required for boat operation Gauges are offered for use in 360 Panels and are not available for retail purchase.
Watertight, fog resistant, and anti-scratch glass face Edge-lit Will fit panels up to 0.8" thickness
METERING
Specifications
Vmxo Tmxo Tmno Ioc Ioc Voltage Max. Operating Temperature Max. Operating Temperature Min. Operating Amperage Operating Current
(with edgelight)
1023B
1022B
See table 158F (70C) -4F (-20C) 180mA <100mA 2.00" (50.80 mm) 2.06" (52.40 mm) 57 in-lb
1030B 1029B
Gauge diameter Mounting hole diameter Back clamp nuts torque Regulatory E Marked
1024B
1028B
Actual size
Gauge Panels
1027B
1510 (Gauge not included) Small Format Label Sets - 8214 and 8217 (p. 117)
PN Width in (mm) Height in (mm) Depth in (mm) Weight lb (kg)
107
108
ACCESSORIES
Blue Sea Systems offers panel accessories for all four panel styles as well as custom panel labels in any language. WeatherDeck and Contura panel accessories include toggle and Contura switches for Blue Sea Systems panels. Both types of switches are available in several pole and throw combinations. Blue Sea Systems has added additional black Contura II switches to expand its current grey and black Contura switch offering. Traditional Metal and 360 Panel System accessories include innovative modular back covers for AC 360 Panels. ABYC standards mandate isolation of AC and DC components on combination panels. Stackable, screw-down covers protect AC components from coming into contact with tools, personnel, and DC wiring. Blue Sea Systems has labels with standard and custom text for all panel formats. Over 500 standard labels and fully custom labels can ship rapidly from the in-house printing facility. All labels are made using a two-layer, back-printed polycarbonate material that resists scratches. Waterproof adhesive ensures a long lasting bond to the panel surface. All labels can be ordered online at bluesea.com.
SECTION INDEX
ABOVE DECK ACCESSORIES
Contura Switch Mounting Panel Plug Contura Switch Mounting Panels Contura Switch Actuators Water Resistant Contura Switches WeatherDeck Toggle Switches (Single Pole) WeatherDeck Toggle Switch (Double Pole) WeatherDeck Toggle Switch Boot 112 112 112 112113 113 113 113
SAFE Boats specifies Blue Sea Systems 360 Panels aboard their Apostle 38 boats used by military and commercial agencies.
109
ACCESSORIES
4121
See table below Quick Connect Tab 0.187 in (4.80 mm) Quick Connect Tabs 6.00 in (152.00 mm) Wire Leads
Imxo Amperage Maximum Operating Illustration Action Below ( ) = Momentary 12 Volts DC 24 Volts DC 125 Volts AC 250 Volts AC 1 1 2 2 2 4 1 3 2 3 2 2 ONOFF (ON)OFF ONOFFON ONOFF(ON) (ON)OFF(ON) (ON)OFF(ON) ONOFF ONON ONOFFON ON(ON) ONOFF(ON) (ON)OFF(ON) 10 Amps 10 Amps 10 Amps 10 Amps 10 Amps 10 Amps 5 Amps 5 Amps 5 Amps 5 Amps 5 Amps 5 Amps 10 Amps 10 Amps 8 Amps 8 Amps 8 Amps 8 Amps 5 Amps 5 Amps 5 Amps 5 Amps 5 Amps 5 Amps 10 Amps 12 Amps 8 Amps 8 Amps 8 Amps 8 Amps 8 Amps 8 Amps 8 Amps 8 Amps 8 Amps 8 Amps 10 Amps 6 Amps 8 Amps 8 Amps 8 Amps 8 Amps 4 Amps 4 Amps 4 Amps 4 Amps 4 Amps 4 Amps
1331
7482 7483 7484 7485 7490 7491 7492 7493 7494 7495
2
PANEL THICKNESS
3
A B
4
+.000 [.00] -.004 [.10]
Features
Isolation of panel AC components and circuits from DC system elements Meets ABYC safety requirements for panels with combined AC and DC loads Modular design consists of interlocking piecesSIDES, TOP, and ENDS Interlocking pieces can be stacked to accommodate large components Cover breakouts allow wire access in any direction UL 94-V0 rated base material resists high heat UL94-VO Polycarbonate 2 qty. #6 Phillips-drive sheet metal screws, 4 qty. #8-32 x 0.5" Phillips-drive machine screws with lock washers
Description 1 module 2 module [A] Height in (mm) 3.23 (82.0) [B] Height in (mm) 6.23 (158.2) Weight lb (kg) 0.56 (0.25) 0.79 (0.36)
4.21" 106.93mm
B A
Specifications
Material Hardware
PN 1331 1341
Provides a method of mounting alternative switch and circuit breakers in the flat rocker aperture
3.23" 82.04mm
4111
PN 4111 4112 4119
4112
Description
4119
Weight lb (kg) 0.03 (0.01) 0.03 (0.01) 0.03 (0.01)
Adapts Push Button Reset-Only Circuit Breaker (p. 32) Adapts A-Series Toggle Circuit Breaker (p. 36) and Panel Switch (p. 112) Adapts Rocker Switch (p. 108)
110
Fills empty Flat Rocker apertures on the 360 Panel System for future use
Provides switching of up to three ML-Series Remote Battery Switches or ML-Series Automatic Charging Relays
Backlit labels and ON indicating lenses in switches Square format label set 4218 (p. 120) 1147 for use with two ML-Series Remote Battery Switches (p. 23) and one ML-Series Automatic Charging Relay (p. 28) 1148 for use with ML-Series Remote Battery Switches (p. 23)
ACCESSORIES
Specifications
Vmxo Voltage Max. Operating: 24V DC
4117
PN 4116 4117
4116
Description Fills Flat Rocker circuit breaker aperture Fills 360 Panel Rocker Switch aperture Weight lb (kg) 0.03 (0.01) 0.03 (0.01)
360 Panels
Provides a 360 Panel System platform for mounting equipment, switching, and monitoring functions
Suitable for mounting accessories and for pad printing
NEW 1479
Specifications
Imxo Amperage Max. Operating Ioc (LED) Amperage Operating Current Temperature Range Pole/Throw Lighting Seals Mounting Hole 20A @ 12V DC, 15A @ 24V DC 18mA -40C 85C SPDT LED rated 100,000 hours half-life Internal and external gasket panel seal 1.45" x 0.83" (36.83 mm x 21.08 mm)
Height in (mm) Depth in (mm) Weight lb (kg) 4.75 (120.65) 4.75 (120.65) 4.75 (120.65)
Regulatory
Meets UL 1500 and ISO 8846 external ignition protection requirements IP67protected against immersion up to 1 meter for 30 minutes
(see inside back cover)
Switches included in retail package of ML-Series Relays (p. 22, 23 and 28)
.55" 14mm
1.965" 49.9mm
1472
PN 1472 1478 Description 12V DC Sockets
NEW 1478
Width in (mm) 4.88 (123.83) Height in (mm) Depth in (mm) Weight lb (kg) 4.75 (120.65) 4.75 (120.65) 1.50 (38.10) 1.50 (38.10) 0.70 (0.32) 0.70 (0.32)
2145, 2155
2146
1.01" 5.7mm
1.51" 38.35mm
For Use With: ML-Series Solenoids, 7701 and 7703 (p. 22) ML-Series Remote Battery Switches, 7700 and 7702 (p. 23) ML-Series Automatic Charging Relays, 7620, 7622, 7621, and 7623 (p. 28) SafetyHub 250 Fuse Block, 7727(page 43) ML-Series Remote Battery Switches, 7712 and 7714 (p. 23)
Weight lb (kg)
111
Modular design permits easy assembly in groups of varying sizes and numbers
Specifically manufactured for use in Blue Sea Systems Contura Water Resistant Panels
ACCESSORIES
1.900" 48.20mm
NEW 7929
8230
8282
8267
PN 8267 8266 8268 8259 8260
8266
Description End Mounting Panel Center Mounting Panel 1 Position Mounting Panel 3 Position Mounting Panel 6 Position Mounting Panel
8268
Width in (mm) 1.19 (30.23) 1.03 (26.16) 1.34 (34.04) 3.40 (86.36) 6.49 (164.85)
Cutout Dimensions
Height in (mm) 2.30 (58.42) 2.30 (58.42) 2.30 (58.42) 2.30 (58.42) 2.30 (58.42)
Use of standard Contura Switches will not maintain the water resistant ingress protection rating of Blue Sea Systems panels. Vibration, shock, thermoshock, moisture and salt spray resistant Mounts in Blue Sea Systems Contura Water Resistant Panels (p. 7475) and Contura Switch Mounting Panels (see left)
Specifications
Imx Amperage Max. Operating Ioc (LED) Amperage Operating Current Lighted Seals Temperature Rating Mounting Hole Weight 20A @ 12V DC, 15A @ 24V DC 18 Milliamps LED rated 100,000 hours 1 2 life Internal and external gasket panel seal -40C to 85C 1.45 in x 0.83 in (36.83 mm x 21.08 mm) 0.09 lb (0.04 kg)
Regulatory
8278
Meets UL 1500 and ISO 8846 external ignition protection requirements 0.06 lb (0.03 kg)
NEW
PN Black with Red Lens 7929 7930 7931 PN Gray 8230 8231 8232 PN Black 8282 8292 8283 Pole Throw SPST SPST SPDT Action ( )=momentary OFFON 0FF(ON) ONOFFON Common Applications lights horn or windshield wipers Combining nav lights or anchor light with independent bulbs bilge pumps labeled dimmer navigational lights wipers or horn combining nav lights with anchor light with shared bulb dual wipers power operated hatches Switching between shunts or current transformers with one meter LEDs
Weight
1 0 2
0.960" 24.38mm
1.240" 31.50mm
1 0 1 0 2 1 0
8294
7939 8275 DPDT ONON 2
8293
112
ACCESSORIES
Specifications
Imxo Amperage Max. Operating Pole, Throw Action Terminal Size Terminal Type Seals Temperature Rating Mounting Hole 20A @ 12V DC, 15A @ 24V DC SPDT (ON)-OFF-(ON) 0.25 in (6.35 mm) Quick Connect Tab Internal and External Gasket Panel Seal -40C to 85C 1.45 x 0.83 in (36.83 x 21.08 mm)
4150
Manufactured for use in WeatherDeck Waterproof Panels (p. 72-73) Nickel-plated brass and phenolic non-corrosive construction
Specifications
Imxo Amperage Max. Operating 10A @ 250V AC 15A @ 125V AC 15A @ 12V DC 0.25 in (6.35 mm) Quick Connect Tab
Weight lb (kg) 0.10 (0.05) 0.10 (0.05) 0.10 (0.05) 0.10 (0.05) 0.10 (0.05)
8216
8291
4153 4154
1.910" 48.51mm
1.933" 49.09mm
0.687" 17.44mm
.062" 1.57mm
0.960" 24.38mm
0.80" 2.03mm
1.479" 37.57mm
1.134" 28.80mm
0.634" 16.10mm
.038" 0.97mm
Cutout Dimensions
SPST
SPDT
DPST
DPDT
LEGEND
Center terminal switch lever Terminal Off Position SPST Single Pole, Single Throw turns a single circuit on and off. SPDT Single Pole, Double Throw turns one of two circuits on. DPST Double Pole, Single Throw turns on two circuits at the same time. DPDT Double Pole, Double Throw controls two functions on two circuits.
See page 111 for Remote Control Contura Switches See pages 74-75 for Contura Water Resistant Panels
4155
Pole, Throw DPDT Action ON-OFF-ON Weight 0.10 lb (0.05 kg) Manufactured for use in WeatherDeck Waterproof Panels (p. 7273) Nickel-plated brass and phenolic non-corrosive construction 30V DC 5A 0.25 in (6.35 mm) Quick Connect Tab
KEYWAY 0.072" 1.82mm x 0.038 0.97mm DP
4138
For mounting on WeatherDeck Waterproof Panel Switches UV resistant material resists discoloration and cracking Rated IP67protected against immersion up to 1 meter for 30 minutes
.062" 1.57mm
0.687" 17.44mm
Specifications
Thread Material Nickel Plated Brass Thread 15/32"-32UNS-2A Weight 0.04 lb (0.02 kg)
.038" 0.97mm
Cutout Dimensions
113
Panel Switches
Mounts in an A-Series toggle circuit breaker aperture to provide multiple throw and switch configurations when circuit protection is provided elsewhere
Fits all A-Series and C-Series circuit breakers without Toggle Guards or Lockout Slides
ACCESSORIES
8035
Ideal for generator starters, bilge pumps, horns, wipers, engine controls and other applications that require switching action other than ONOFF or different pole configuration separate from circuit protection Panel switches mount in Blue Sea Systems A-Series Toggle Circuit Breaker Panels For use with A-Series Toggle Circuit Breaker Mounting Panel (p. 50) Supplied with mounting adapter for standard 5 8" circuit breaker mounting hole Nickel-plated brass and phenolic non-corrosive construction
Specifications
Imxo Amperage Max. Operating
Toggle Switches 10A @ 250V AC 15A @ 125V AC 15A @ 32V DC 0.25 in (6.35 mm) Quick Connect Tab White
Push Button Switch 3A @ 250V AC 6A @ 125V AC 6A @ 32V DC 0.25 in (6.35 mm) Quick Connect Tab White
Weight lb (kg) 0.07 (0.03) 0.08 (0.04) 0.08 (0.04) 0.08 (0.04) 0.08 (0.04) 0.08 (0.04) 0.08 (0.04) 0.08 (0.04) 0.08 (0.04) 0.08 (0.04)
8037
Pole/Throw SPST SPST SPST SPDT SPDT SPDT DPST* DPST DPDT DPDT
Action ( ) = momentary OFF(ON) OFFON OFF(ON) ONOFFON (ON)OFFON (ON)OFF(ON) OFFON(ON) OFFOFF(ON) OFFON ONOFFON (ON)OFFON
Provides a method of mounting Push Button Reset-Only Circuit Breakers into the magnetic circuit breaker aperture
4111
Specifications
Vmxo Voltage Max. Operating Ioc Amperage Operating Current
ADAPTER
8065
Weight lb (kg) 0.08 (0.04) 0.05 (0.02) 0.09 (0.04) 0.11 (0.05)
114
Corrosion resistant materials to ensure solid contact and low voltage drop
Designed to withstand the rigors of wet environments and constant vibration Large contact surfaces for good electrical connection Twist lock systemplug locks securely into socket Internal strain relief and cord seal Nickel plated copper alloy used for all current carrying components Plug has a sealing ring to keep out spray and make it seat firmly in the socket Socket features a watertight cap, easy installation, and interlocks with plug 1012 and 1013 heavy duty 18 gauge wire 1012 cord reaches up to 6 feet 12V DC 15A DC (socket) 10A DC (plug)
NEW
Protective cap with tether keeps dust and spray from shortening the life of the charger. Made with corrosion resistant materials which ensure a solid contact and low voltage drop. Compatible with popular mobile devices Protective cap Corrosion resistant materials Protected from overheating
ACCESSORIES
Specifications
Vn Voltage Nominal Imxo Amperage Max. Operating Imxo Amperage Max. Operating
Dual USB Charger Socket - 1016 Easy to install in existing 12V DC socket hole providing convenient access for charging mobile devices Dual USB Charger Plug - 1017 Easy to use in common 12V DC sockets found in boats, cars, and recreational vehicles
1016
Specifications
USB 2.0 Input Voltage 12V DC Output Voltage 5V DC +/-5% Max. Output Current 2.1A DC (total) Dual USB Charger Socket: Cut Out Dimensions 1-3/16" Dia. (30 mm)
1013
Regulatory
FCC Part 15: Subpart B Compliant
E13 RoHS
PN 1016 1017
1011 See page 111 for the 360 Panel Socket and Dual USB Charger Mounting Panels. 1014 1010
Directly replaces LEDs used in Blue Sea Systems Traditional Metal circuit breaker panels
Simple push-in installation mounts in any thickness material Useful as general indicator and alarm lights
Specifications
Vmxo Voltage Max. Operating Mounting Hole Size Power Consumption Wire Gauge
WeIght lb (kg) 0.08 (0.04) 0.10 (0.05) 0.54 (0.24) 0.50 (0.23) 0.07 (0.03) 0.20 (0.09) PN 8033 8171 8172 8169 8066 8034 8167 8166 8134 Color Amber Red Green Amber Red Green Amber Red Green Nominal Voltage 12/24V DC 12/24V DC 12/24V DC 120V AC 120V AC 120V AC 250V AC 250V AC 250V AC Current (mA) 1.5 @ 12V, 3.1 @ 24V 1.5 @ 12V, 3.2 @ 24V 1.5 @ 12V, 3.0 @ 24V 2.3 @ 120V 2.7 @ 120V 2.3 @ 120V 1.1 @ 250V 1.1 @ 250V 1.1 @ 250V Power Consumption (mW) 19 @ 12V, 75 @ 24V 19 @ 12V, 77 @ 24V 19 @ 12V, 73 @ 24V 278 @ 120V 326 @ 120V 278 @ 120V 276 @ 250V 276 @ 250V 276 @ 250V Circuit Resistor Resistor Resistor Resistor Resistor Resistor Resistor + Diode Resistor + Diode Resistor + Diode Weight lb (Kg) 0.03 (0.01) 0.03 (0.01) 0.03 (0.01) 0.03 (0.01) 0.03 (0.01) 0.03 (0.01) 0.03 (0.01) 0.03 (0.01) 0.03 (0.01)
1012
Description
8033
8171
8172
Single Plug with Single Socket Extension Single Plug with Dual Socket Extensions Mounting Bracket for Socket (1011)* Plug and Socket Set - Includes 1010 and 1011
See page 111 for the 360 Panel Socket and Dual USB Charger Mounting Panels.
115
Toggle Guard
Enables safe management of multiple AC sources which use double pole circuit breakers
Allows only 1 double pole AC circuit breaker to be activated at a time Guarantees that AC power from 2 or more sources (shore power, genset, or inverter) will not be mixed Fits all double pole A-Series Toggle Circuit Breakers (p. 50) Uses circuit breaker mounting screw holes Includes mounting screws
ACCESSORIES
Specifications
Mounting #6 Flat Head Screw
Specifications
Mounting #6 Flat Head Screw
Specifications
Mounting AC Sources #6 Pan Head Screw 2
4100 (2 shown)
PN 4100 Description Toggle Guard Weight lb (kg) 0.05 (0.02)
4125 4130
Provides electrical insulation for many of Blue Sea Systems traditional metal circuit breaker panels
4126
PN 4125 4126 Poles 2 2 AC Sources 2 3 Weight lb (kg) 0.04 (0.02) 0.06 (0.03)
4131
PN 4130 4131 Poles 2 3 AC Sources 2 2 Weight lb (kg) 0.06 (0.03) 0.17 (0.08)
Specifications
Material UL-94 V0 Thermoplastic
Description Cover for 5-1 4" x 3-3 4" Cover for 5-1 4" x 7-1 2" Cover for 10-1 2" x 7-1 2" Cover for 1 Column x 8 Position + Meter Cover for 2 Column x 10 Position + Meter
Weight lb (kg) 0.12 (0.05) 0.20 (0.09) 0.50 (0.23) 0.24 (0.11) 0.38 (0.17)
Yamaha Boats use the Blue Sea Systems 360 Panel System with custom labels in Japanese on their NYTRO sportboat.
116
Labels
Can't find the right label? Custom labels can be ordered online in square and large formats in any language with artwork provided. Blue Sea Systems offers labels with standard and custom text for all panel formats. Custom labels ship rapidly due to an in-house printing facility, and over 500 standard labels are ready to order. All labels are made using a durable polycarbonate material, waterproof adhesive, and are back printed for scratch resistance. To order standard labels online or download a custom label order form, go to bluesea.com/labels.
Used with most Blue Sea Systems Contura Switch Water Resistant Panels (p. 75) or ST Blade Fuse Block (p. 39)
0.375" 9.53mm
0.625" 15.88mm
ACCESSORIES
PN 8214 8217
Used with 360 Panel System (p. 76), Battery Management (p. 2021) and WeatherDeck Panels (p. 7273)
Reinforced, weatherproof material Available for purchase in sets or individually (p. 117120) For a list of labels included see (p. 120)
Description DC Labels DC Labels DC Labels DC Labels DC Panel Basic AC Panel Basic DC Panel Extended AC Panel Extended
Quantity 30 Labels 30 Labels 60 Labels 120 Labels 30 Labels 30 Labels 120 Labels 120 Labels
0.590" 14.99mm
4215
4140
Used on any m-Series, e-Series and HD-Series battery switches (p. 1517)
Reinforced, weatherproof material
Used on Traditional Metal Panels, ST Glass Fuse Block and selected Contura Waterproof Panels
Reinforced, weatherproof material Used on Contura Water Resistant Fuse Panels 8053, 8054 (p. 75) Available for purchase in sets or individually (p. 117120) For a list of labels included see (p. 120)
PN 8031 8067 8030 8039 Color Black Black Black Black Description AC Panel Basic AC Panel Extended DC Panel Basic DC Panel Extended Quantity 30 Labels 120 Labels 30 Labels 120 Labels
BLANK
BATTERY 1
BATTERY 2
BATTERY 3
BOW THRUSTER
CHASSIS
ENGINE
ENGINE 1
ENGINE 2
ENGINE MID
ENGINE PORT
ENGINE STARBOARD
GENERATOR
HOUSE
PARALLEL
INVERTER
GROUND
WINDLASS
1.438" 36.51mm
7902 8031
Color Quantity
White 18 labels
0.438" 11.11mm
117
Label Text
LABEL #1 LABEL #2 (BLANK) 12 VOLT DC 12 VOLT DC OUTLETS 12 VOLT OUTLETS INSIDE 12 VOLT OUTLETS OUTSIDE 120 VOLT / 60 HZ SHORE POWER 120 VOLT AC / 60 HZ 120 VOLT AC OUTLETS 120/240V 60 HZ 120/240V 60 HZ SHORE POWER 230 VOLTS AC 50 HZ 24 VOLT DC 24 VOLT DC OUTLET 240 VOLTS AC 240 VOLTS AC / 60 HZ 250 VOLT 50HZ SHORE POWER 250 VOLTS AC / 50 HZ AC BUS 1 AC COMPRESSOR AC FAN AC MAIN AC PANEL AC POWER AC REFRIGERATOR AC SUB PANEL ACCENT LIGHT ACCESSORY ADF AERATOR AFT CABIN AFT CABIN LIGHTS AFT CABIN OUTLETS AFT CABIN SUMP AFT DISCHARGE PUMP AFT HEAD AIR COMPRESSOR AIR CONDITIONER AIR CONDITIONER 2 AIR CONDITIONER 3 AIR CONDITIONER 4 AIR CONDITIONER PUMP AIR HORN AIS ALARM ALARM SYSTEM ALTERNATOR ALTERNATOR DISCONNECT AMPLIFIER ANCHOR LIGHT ANCHOR LIGHT MAIN ANCHOR LIGHT MIZZEN ANCHOR WASH DOWN APPLIANCES ARCH LIGHTS AUDIO/VIDEO SYSTEM AUTO FILL AUTO/MAN AUTO/MAN AUTOMATIC CHARGING RELAY AUTOPILOT BAIT PUMP BAITWELL BALLAST CONTROLS BALLAST PUMP BAR BATHROOM BATTERY BATTERY 1 BATTERY 2 BATTERY CHARGER BATTERY CHARGER 2 BATTERY COMPARTMENT BATTERY PARALLEL BATTERY SWITCH BEACON BEDROOM
Label No.
0485 0055 0056 0057 0058 0059 0060 0061 0062 0063 0064 0453 0559 0065 0066 0067 0068 0069 0070 0071 0072 0073 0074 0075 0501 0076 0077 0078 0079 0080 0081 0082 0083 0084 0085 0086 0087 0088 0089 0090 0091 0092 0093 0537 0094 0095 0096 0097 0098 0508 0099 0575 0100 0101 0102 0103 0104 0105 0106 0107 0514 0108 0109 0110 0111 0112 0113 0114 0115 0116 0117 0118 0119 0120 0121 0122 0123 0124
Label Text
BEDROOM SLIDEOUT BILGE BILGE ALARM BILGE ALARM 2 BILGE ALARM 3 BILGE ALARM 4 BILGE LIGHTS BILGE PUMP BILGE PUMP 2 BILGE PUMP 3 BILGE PUMP 4 BILGE PUMP ON-OFF-AUTO BLANK WHITE WRITABLE BLOWER BOAT DAVIT BOOM LIGHT BOW LIGHT BOW THRUSTER BRIDGE BRIDGE INSTRUMENTS BRIDGE LIGHTS BRIDGE OUTLETS CABIN CABIN 2 CABIN 2 FAN CABIN 2 LIGHTS CABIN 2 OUTLETS CABIN 3 CABIN 3 LIGHTS CABIN 3 OUTLETS CABIN 4 CABIN 4 LIGHTS CABIN 4 OUTLETS CABIN FAN CABIN HEATER CABIN LIGHTS CABIN OUTLETS CABLEMASTER CASSETTE PLAYER CB RADIO CCTV CD PLAYER CELLULAR PHONE CENTER LIVEWELL CHARGER/INVERTER CHART LIGHT CHART PLOTTER CHOKE CIRCULATOR PUMP CLOCK CLOSET LIGHT CO DETECTOR COCKPIT LIGHTS COCKPIT REFRIG COLOR SOUNDER COMM ELECTRONICS COMPARTMENT HEATER COMPARTMENT LIGHT COMPASS LIGHT COMPUTER COMPUTER DISPLAY CONDENSER PUMP CONSOLE LIGHT CONVERTER COOKING GRILL COOKTOP COOLING PUMP COURTESY LIGHTS CREW LIGHTS CREW QUARTERS DAVIT DC LIGHTS DC MAIN DC OUTLETS DC REFRIGERATOR DC SUB PANEL DECK DECK LIGHTS
Label No.
0125 0126 0127 0128 0129 0130 0131 0132 0133 0134 0135 0136 0137 0567 0568 0138 0139 0140 0141 0142 0143 0144 0145 0146 0566 0580 0147 0469 0148 0149 0150 0151 0545 0581 0562 0547 0158 0159 0160 0161 0162 0163 0164 0165 0166 0167 0168 0169 0152 0153 0154 0155 0156 0157 0170 0171 0546 0172 0173 0174 0175 0176 0177 0178 0179 0180 0181 0182 0183 0184 0185 0186 0187 0459 0538 0188 0520 0521
Label Text
DECK LIGHTS AFT DECK LIGHTS FWD DECK LIGHTS PORT DECK LIGHTS STBD DEFROSTER DEPTH RECORDER DEPTH SOUNDER DEPTH/SPEED DESALINATOR DIMMER DINING AREA LIGHTS DINING AREA OUTLETS DISCHARGE PUMP DISCHARGE PUMP 2 DISCHARGE PUMP 3 DISHWASHER DISPOSAL DIVE COMPRESSOR DOCKING LIGHT PORT DOCKING LIGHT STBD DOCKING LIGHTS DOWN RIGGER DRYER DUMP VALVES ECU ELCI ELECTRIC HATCH ELECTRONIC CONTROL UNIT ELECTRONICS EMERGENCY BACKUP SYS EMERGENCY LIGHTS EMERGENCY PUMPS ENGINE ENGINE 1 ENGINE 2 ENG 1/ENG 2 ENGINE ALARM ENGINE BLOCK HEATER ENGINE CONTROL PORT ENGINE CONTROL STBD ENGINE CONTROLS ENGINE DRIVEN REFRIG ENGINE EXHAUST FAN ENGINE HATCH ENGINE HEATER PORT ENGINE HEATER STBD ENGINE INSTRUMENTS ENGINE OIL PAN PUMP ENGINE ROOM BILGE ALARM ENGINE ROOM BLOWER ENGINE ROOM HEATER ENGINE ROOM LIGHTS ENGINE ROOM OUTLETS ENGINE ROOM PANEL MAIN ENGINE SHUTDOWN ENGINE TEMP ENGINES ENTERTAINMENT CENTER ENTRANCE DOOR ENTRY STEP EXHAUST FAN EXHAUST TEMP EXTERIOR EXTERIOR LIGHTS FAN FAN 2 FAN 3 FAN 4 FAX FILLING PUMP FIRE ALARM FIRE EXT FIRE HORN FISH FINDER FISHBOX DRAIN FISHBOX ICEMAKER FISHBOX PUMP FISHBOX REFRIGERATOR
Label No.
0189 0487 0488 0576 0190 0191 0192 0193 0194 0195 0196 0197 0539 0198 0199 0200 0201 0202 0203 0204 0482 0561 0205 0206 0207 0208 0209 0210 0211 0507 0212 0213 0214 0215 0216 0217 0218 0529 0528 0219 0220 0221 0222 0223 0224 0490 0225 0226 0227 0523 0228 0229 0454 0230 0466 0455 0578 0231 0232 0233 0234 0510 0235 0236 0237 0238 0239 0240 0241 0242 0243 0244 0245 0246 0247 0248 0249 0250
Label Text
FISHING LIGHT FISHWELL PUMP FISHWELL PUMP 2 FLOAT SWITCH FLOOD LIGHTS FLOSCAN FLYBRIDGE FLYBRIDGE ELECTRONICS FLYBRIDGE LIGHTS FLYBRIDGE OUTLETS FOG LIGHTS FOREDECK LIGHT FORWARD BILGE FREEZER FRESH WATER FRESH WATER PUMP FRESH WATER PUMP 2 FRESH WATER PUMP 3 FRESH WATER PUMP 4 FRESH WATER WASH DOWN FRONT SLIDEOUT FUEL GAUGE FUEL PRIMER PUMP FUEL PUMP FUEL PUMP 2 FUEL PUMP 3 FUEL PUMP 4 FUEL TANK HEATER FUEL TRANSFER FUME DETECTOR FURLER JIB FURLER MAINSAIL FURLER SPINNAKER FURNACE FWD CABIN FWD CABIN LIGHTS FWD CABIN OUTLETS FWD DISCHARGE PUMP FWD HEAD GALLEY GALLEY APPLIANCES GALLEY DRAIN GALLEY FAN GALLEY LIGHTS GALLEY OUTLETS GALVANIC ISOLATOR GARBAGE DISPOSAL GAS ALARM GENERAL PURPOSE GENERATOR GENERATOR 1 GENERATOR 2 GENERATOR OFF ON START GENERATOR ROOM BLOWER GENERATOR RUNNING GENERATOR STOP GFCI GFI OUTLET GPS GPS/LORAN GPS/PLOTTER GUN LOCKS GYRO COMPASS HAILER HALLWAY LIGHTS HALON FIRE SYSTEM HAM RADIO HEAD HEAD 2 HEAD 2 FAN HEAD 2 OUTLETS HEAD 3 HEAD 3 FAN HEAD 3 OUTLETS HEAD 4 HEAD 4 FAN HEAD 4 OUTLETS HEAD FAN
ACCESSORIES
118
Label Text
HEAD LIGHTS HEAD LIGHTS 2 HEAD LIGHTS 3 HEAD LIGHTS 4 HEAD OUTLETS HEADLIGHTS HEATER HEATER & AIR CONDITIONER HEATER 2 HEATER 3 HEATER 4 HELM ELECTRONICS HELM GAUGES HELM INSTRUMENTS HIGH WATER ALARM HOLDING TANK HOLDING TANK ALARM HOLDING TANK PUMP HOOD FAN HOOD LIGHT HORN HOT TUB HOT WATER PUMP HOUSE HOUSE/ENG HOUSE/GEN HYDRAULIC ALARM HYDRAULIC SYSTEM HYDRAULIC TANK ALARM HYDRAULIC VALVE ICE MAKER IGNITION IGNITION PORT IGNITION STBD INSTRUMENT LIGHTS INSTRUMENTS INTERCOM INTERCOM HAILER INTERCOM/TELEPHONE INTERIOR LIGHTS INTERNET INVERTER INVERTER 2 INVERTER AC BUS INVERTER AC SUPPLY INVERTER DC SUPPLY INVERTER OUTLET ISOLATION TRANSFORMER KITCHEN KITCHEN SLIDEOUT KNOTMETER LAZARETTE LIGHTS LECTRASAN LIGHTER LIGHTS LIGHTS 2 LIGHTS 3 LIGHTS 4 LIGHTS AFT LIGHTS AFT CABIN LIGHTS FWD LIGHTS MASTER CABIN LIGHTS PANTRY LIGHTS PILOTHOUSE LIGHTS PORT LIGHTS SETTEE LIGHTS STBD LIVEWELL LIVEWELL INPUT LIVEWELL OUTPUT LOCKER LIGHTS LOG LORAN LPG CONTROL LUBE OIL PUMP MACERATOR PUMP MAIN MAIN BREAKER
Label No.
0311 0312 0313 0314 0315 0572 0316 0317 0551 0574 0318 0319 0320 0456 0321 0322 0323 0324 0325 0326 0327 0565 0328 0329 0331 0563 0332 0330 0333 0334 0335 0336 0505 0337 0506 0338 0503 0339 0504 0458 0496 0340 0540 0534 0341 0552 0342 0343 0457 0344 0345 0346 0497 0498 0554 0347 0348 0349 0350 0351 0352 0579 0353 0483 0354 0355 0356 0357 0358 0359 0360 0361 0489 0362 0363 0364 0365 0366
Label Text
MAIN CABIN MAIN CABIN LIGHTS MAIN CABIN OUTLETS MAIN SAIL FURLING MAP LIGHT MARINE SANITATION DEVICE MAST LIGHTS MASTHEAD LIGHT MEMORY MERCATHODE MICROWAVE MINI DISC PLAYER MIZZEN FLOOD NAV LIGHT ANCHOR OFF NAV NAV STATION ELECTRONICS NAV STATION GAUGES NAV STATION INSTRUMENTS NAV STATION LIGHTS NAVIGATION ELECTRONICS NAVIGATION INSTRUMENTS NAVIGATION LIGHTS NETWORK NIGHT LIGHTS OFF OIL CHANGE PUMP OIL GAUGE ON ON-OFF OUTLETS OUTLETS 2 OUTLETS 3 OUTLETS 4 OUTLETS AFT OUTLETS DECK OUTLETS ENGINE ROOM OUTLETS EXTERIOR OUTLETS FORWARD OUTLETS INTERIOR OUTLETS PILOT HOUSE PANEL LIGHTS PILOT HOUSE FAN PORT PORT FISHBOX PORT LIVEWELL PORT THRUSTER PORT/STBD ENG POWER POWER WASHER PRE-HEAT PRIMARY WINCHES PRINTER PUMP PUMP BLACK WATER PUMP GRAY WATER PUMPOUT RACK LIGHTS RACK OUTLETS RADAR RADAR ARCH LIGHTS RADIO RANGE RCBO RDF REAR SLIDEOUT RECEIVER RECEPTACLE REFRIGERATOR REFRIGERATOR PUMP REFRIGERATOR/FREEZER REGULATOR REVERSE POLARITY ROD LOCKER RUDDER ANGLE INDICATOR RUNNING LIGHTS SAILING CONTROLS SAILING INSTRUMENTS SALOON SALOON HEATER
Label No.
0367 0368 0369 0370 0371 0372 0373 0374 0375 0376 0377 0378 0379 0380 0381 0463 0464 0382 0383 0384 0385 0386 0486 0387 0388 0542 0389 0390 0391 0392 0393 0394 0558 0395 0396 0398 0399 0397 0541 0533 0400 0401 0569 0402 0403 0577 0404 0509 0405 0406 0407 0408 0409 0410 0411 0412 0564 0413 0414 0415 0416 0417 0465 0418 0419 0518 0420 0478 0421 0422 0527 0423 0424 0425 0426 0535 0427 0428
Label Text
SALOON LIGHTS SALOON OUTLETS SALT WATER PUMP SAT/COM SAT/NAV SATELLITE DISH SCRUBBER SEARCHLIGHT SEARCHLIGHT HAND HELD SEARCHLIGHT REMOTE SEAWATER TEMP SEAWATER WASH DOWN SECURITY SYSTEM SHIP SHORE SHORE 1 SHORE 2 SHORE CORD REEL SHORE POWER SHORE POWER CORD SHOWER SUMP PUMP SINK DRAIN SLIDEOUT SOLAR PANEL SONAR SONAR/ACC SPARE SPEED/LOG SPREADER LIGHTS SPREADER LT MIZZEN SSB STABILIZER STAIR LIGHT STARBOARD START START PORT START STBD START-STOP STBD FISHBOX STBD LIVEWELL STBD THRUSTER STEAMING LIGHT STEERING VALVE STEP LIGHT STEREO STEREO MEMORY STERN LIGHT STERN THRUSTER STOP STOVE STOVE/MICROWAVE STROBE LIGHT SUB PANEL SUMP PUMP SUMP PUMP 2 SYNCHRO TANK GAUGE TAPE DECK TELEPHONE SYSTEM TEST TOWING LIGHTS TRACK LIGHTS TRANSFER TRANSFER PUMP TRANSFORMER TRANSFORMER SECONDARY TRASH COMPACTOR TRAVEL LOCKS TRICOLOR LIGHT TRIM TABS TROLLING MOTOR TV TV ANTENNA TV/STEREO TV/VCR UNDERWATER LIGHT UPS SYSTEM UTILITY
Label No.
0429 0430 0431 0432 0511 0512 0433 0434 0543 0513 0435 0436 0437 0562 0438 0439 0440 0441 0442 0443 0444 0571 0553 0445 0477 0446 0522 0447 0448 0449 0472 0450 0451 0452 0557
Label Text
VACUUM VACUUM PUMP VCR VHF VHF 1 VHF 2 VIDEO PLOTTER VIDEO SYSTEM WASHDOWN WASHDOWN PUMP WASHER WASHER/DRYER WATER ALARM WATER GAUGE WATER HEATER WATER LEVEL WATER MAKER WATER PRESSURE WATER PUMP WEATHER FAX WEATHER INSTRUMENT WIFI WINCH WINCHES WIND GENERATOR WIND INSTRUMENTS WIND SHIELD VENT WINDEX LIGHT WINDLASS WINDSHIELD WASHER WIPER CENTER WIPER PORT WIPER STBD WIPERS WIRELESS
119
ACCESSORIES
4217
(BLANK) 12 VOLT DC 12 VOLT DC OUTLETS 24 VOLT DC AIR HORN ANCHOR LIGHT MAIN ANCHOR LIGHT MIZZEN ANCHOR WASH DOWN APPLIANCES ARCH LIGHTS AUTO/MAN BAITWELL BATTERY BATTERY PARALLEL BILGE ALARM BILGE PUMP 2 BILGE PUMP ON-OFF-AUTO BOW LIGHT BOW THRUSTER BRIDGE INSTRUMENTS BRIDGE LIGHTS CABIN CB RADIO CD PLAYER CHART LIGHT CHART PLOTTER COCKPIT LIGHTS COMPASS LIGHT COURTESY LIGHTS DAVIT DC OUTLETS DC SUB PANEL DECK LIGHTS DEFROSTER DEPTH/SPEED DIMMER DISCHARGE PUMP DOCKING LIGHT PORT DOCKING LIGHT STBD DOCKING LIGHTS DOWN RIGGER ELECTRIC HATCH ENGINE HATCH ENGINE INSTRUMENTS ENGINE ROOM BLOWER ENGINE ROOM LIGHTS ENGINE SHUTDOWN ENTRY STEP FAN FAN 2 FIRE ALARM FIRE EXT FISH FINDER FISHING LIGHT FISHWELL PUMP FLOOD LIGHTS FLYBRIDGE FLYBRIDGE ELECTRONICS FLYBRIDGE LIGHTS FOG LIGHTS FOREDECK LIGHT FRESH WATER PUMP FRESH WATER WASH DOWN FUEL PUMP FUEL TRANSFER FURLER JIB FURLER MAINSAIL GALLEY GAS ALARM GPS/PLOTTER HAILER HAM RADIO HEAD HEATER IGNITION INSTRUMENT LIGHTS INTERCOM HAILER LAZARETTE LIGHTS LIGHTER LIGHTS LIVEWELL LOCKER LIGHTS LPG CONTROL MAIN MAST LIGHTS MASTHEAD LIGHT MIZZEN FLOOD NAVIGATION ELECTRONICS NAVIGATION INSTRUMENTS NAV LIGHT ANCHOR OFF NAV ON-OFF OUTLETS PUMP PUMPOUT RADIO ROD LOCKER RUDDER ANGLE INDICATOR SAILING CONTROLS SAILING INSTRUMENTS SALT WATER PUMP SEAWATER WASH DOWN SHOWER SUMP PUMP SOLAR PANEL SSB START-STOP STERN LIGHT STROBE LIGHT SUMP PUMP TRANSFER TRICOLOR LIGHT TROLLING MOTOR WASHDOWN PUMP WASHDOWN WINCHES WIND GENERATOR WIND INSTRUMENTS WINDSHIELD WASHER WIPER CENTER WIPER PORT WIPER STBD
ACCESSORIES
4218
12 VOLT DC 24 VOLT DC ALARM BILGE PUMP BILGE PUMP 2 BILGE PUMP 3 BILGE PUMP 4 BOW THRUSTER CLOCK DC MAIN DC SUB PANEL ELECTRONICS ENGINE ENGINES ENG 1/ENG 2 GENERATOR HOUSE HOUSE/ENG HOUSE/GEN INVERTER LIGHTS MEMORY PORT/STBD ENG RADAR RADIO SOLAR PANEL VHF WINCH WINDLASS Blank (Write On)
4216
(BLANK) 12 VOLT DC 12 VOLT DC OUTLETS ANCHOR WASH DOWN BAITWELL BATTERY BATTERY PARALLEL BILGE BILGE PUMP 2 BILGE PUMP ON-OFF-AUTO BOW LIGHT CABIN CB RADIO CELLULAR PHONE CHART LIGHT CHART PLOTTER COCKPIT LIGHTS COMPASS LIGHT COURTESY LIGHTS DAVIT DC OUTLETS DC SUB PANEL DECK LIGHTS DOCKING LIGHTS DOWN RIGGER ELECTRIC HATCH ENGINE ROOM BLOWER ENGINE ROOM LIGHTS FAN FISH FINDER FISHING LIGHT FISHWELL PUMP FLOOD LIGHTS FRESH WATER PUMP FUEL PUMP GALLEY OUTLETS GAS ALARM GPS/PLOTTER HEAD IGNITION INSTRUMENT LIGHTS LIGHTS LIVEWELL MACERATOR PUMP NAV LIGHT ANCHOR-OFF-NAV OUTLETS PUMPOUT RADIO SEAWATER WASH DOWN SHOWER SUMP PUMP SSB STERN LIGHT STROBE LIGHT TRICOLOR LIGHT TROLLING MOTOR WASHDOWN WATER MAKER WINCHES WIPER PORT WIPER STBD
120
DC
OR
G27
G24
G24
OR
G27
G27
OR
4D
6511,100 CCA
3,000 AIC
1,500 AIC
APPENDIX
GOLF CART
OR
8D
OR
4D
4D
Over 1,100 CCA 32 VOLTS 1,250 CCA or Less Over 1,250 CCA
5,000 AIC
2,500 AIC
Considerations for DC Main Circuit Protection Mounting Placementdistance from power source.
The DC Main circuit protection system uses circuit breakers or fuses to protect the wires of the DC Main distribution system. The American Boat and Yacht Council (ABYC) publishes voluntary standards for the type and placement of the fuse or circuit breaker to be used as a DC Main circuit protection device. Wire intended to carry engine starting currents between the batteries, the switch, and the starter is not required to have main circuit protection devices installed. Maximum mounting placement dimensions for a fuse or circuit breaker are 7" if the conductor is not housed in a sheath or enclosure in addition to the wire insulation, 40" if the conductor is housed in a sheath or enclosure in addition to the wire insulation, and 72" if the conductor is connected directly to the battery and housed in a sheath or enclosure in addition to the wire insulation.
1,500 AIC
2,500 AIC * Battery cold cranking performance rating at -17.8C (0F): The discharge load in amps that a battery at -17.8C (0F) can deliver for 30 seconds, and maintain a voltage of 1.2 Volts per cell or higher, (e.g. 7.2 Volts for a 12 Volt battery). The CCA for the battery icons in this chart is an approximation and could be slightly higher or lower. Consult the battery manufacturers specifications for precise CCA ratings. A battery rated in MCA will have a CCA capacity approximately 80% of MCA
ABYC E-11 requires the use of circuit breakers that can be reused and reset and that they be applied as per the table above. The standard does not strictly require that fuses be applied in the same way, but it is an issue to consider, especially with high amp fuses used to protect panel feeders or inverters. Fuses under 10 Amp rating generally have such a high internal resistance they prevent fault currents from reaching 1000 Amps in 12 Volt circuits. The apparent contradiction when using these fuses for bilge pumps and other circuits directly off the battery is less of an issue than it might seem. If a fuse blows, and the case appears to be cracked or metal has been ejected, the fuse holder should be replaced.
REFERENCE DATA
Ohms Ohms mm dia /1000ft /1000m 0.98 1.02 1.13 1.29 1.38 1.63 1.78 2.05 2.26 2.59 2.76 3.27 3.6 4.1 4.5 5.2 5.6 5.8 6.5 6.7 7.3 8.0 8.3 9.3 9.4 10.4 11.0 11.7 12.4 13.8 7.29 6.67 5.47 4.17 3.65 2.63 2.19 1.65 1.37 1.04 0.91 0.65 0.55 0.41 0.34 0.26 0.22 0.21 0.16 0.16 0.13 0.109 0.102 0.081 0.078 0.064 0.058 0.051 0.046 0.036 23.92 21.88 17.94 13.70 11.96 8.63 7.18 5.42 4.49 3.41 2.99 2.14 1.79 1.35 1.12 0.85 0.72 0.67 0.53 0.51 0.42 0.36 0.34 0.27 0.26 0.21 0.19 0.17 0.15 0.12
SAE conductors are smaller than equivalent AWG by 5% to 12% with current capacity typically less by 7%. ISO Ratings for metric wire are slightly less than these values derived from ABYC VI-A ratings.
See the Blue Sea Systems Circuit Wizard at circuitwizard.bluesea.com or pages 124-126 for more assistance with wire and circuit protection selection.
For bundles of 4 to 6 conductors multiply by 0.857 For bundles of 7 to 24 conductors multiply by 0.714 For bundles of 25 or more, conductors multiply by 0.571 Wires counted in bundles need not include: 1. Wires carrying intermittent currents no more than rating per VI-A and for less than one minute per mm of diameter, and not repeating more often than a delay of 5X times active duration. 2. Wires carrying load currents at less than 50% of the wire rating per table VI-B.
121
Battery Management 2 Battery - 1 Engine Traditional Configuration Wiring Schematics 1 Selector Battery Switch 1 Automatic Charging Relay for Typical Applications
Batteries are at the heart of the electrical system found on any boat or vehicle. Proper battery management, including switching and charging, is essential for safe and reliable operation. The following basic wiring diagrams show how batteries, battery switches, and Automatic Charging Relays are wired together from a simple single battery / single engine configuration to a two engine, one generator, and four battery bank system. For more detailed wiring guidelines please consult a qualified marine electrician or one of the many books available on the subject.
Note: The ACRs pictured are representative of any ACR. The battery switches are representative of any Battery Switch of the same model.
2 Battery - 2 Engine
Simple System
House battery is shared with one engine. One engine battery is in reserve.
1 Dual Circuit Plus Battery Switch 1 ON-OFF Battery Switch 1 Automatic Charging Relay
APPENDIX
House Engine
ACR
Start House/Start
Simple to use
Simple System
Engines share one battery. House battery is in reserve. 1 Dual Circuit Plus Battery Switch 1 ON-OFF Battery Switch
1 Automatic Charging Relay
1 Battery - 1 Engine
ON-OFF Battery Switch
House Engine
Engine Engine 2 House
House Engine
Most Flexible
House
Flexible
Engine
For m-Series Battery Switches the Paralleling Link Bus 9159 can be used.
House
Engine
For m-Series Battery Switches the Paralleling Link Bus 9159 can be used.
House
122
3 Battery - 2 Engine
Simple Operation
Can parallel batteries for extra starting power.
2 Dual Circuit Plus Battery Switches 2 Automatic Charging Relays
APPENDIX
ACR House
Generator
ACR
Start
ACR
Start
ACR
House
ACR House
Generator
ACR
Start
ACR
Start
ACR
House
Normal - Set all switches to position 1 Parallel - Set all switches to position 1+2 Isolate - Set Load switch to Position 2 and Source Switch to position 1+2
Normal - Set all switches to position 1 Parallel - Set all switches to position 1+2 Isolate - Set Load switch to Position 2 and Source Switch to position 1+2
123
A B C D
APPENDIX
DROP 3% VOLTAGE
0 to 20 ft 30 ft 50 ft 65 ft 80 ft
8 AWG
6 AWG
6 AWG
6 AWG
8
4 AWG
4 AWG
4 AWG
2 AWG
1 AWG
6 AWG
4 AWG 4 AWG
4 AWG 2 AWG
2 AWG
8
2|0 AWG
0 AWG 2|0 AWG 3|0 AWG 4|0 AWG 3|0 AWG 4|0 AWG
10 AWG
CIRCUIT LENGTH
8 AWG
4 AWG
4 AWG
2 AWG
2 AWG
1 8 AWG 0 AWG
1 AWG
3|0 AWG
4 AWG
4|0 AWG
4|0 AWG
2 AWG
WIRE SIZE CHART Black circles indicate actual diameter of wire (not including insulation)
16 AWG 14 AWG 12 AWG 10 AWG 8 AWG 6 AWG 4 AWG 2 AWG 1 AWG 0 AWG
2|0 AWG 3|0 AWG 4|0 AWG
U.S. Coast Guard and other regulatory agencies require all circuits, except the starting circuit, to be protected with a circuit breaker or a fuse. For additional informaiton consult the Circuit Wizard at www.circuitwizard.bluesea.com
Copyright 2012 Blue Sea systems Inc. All rights reserved. Unauthorized copying or reproduction is a violation of applicable laws.
124
A B
APPENDIX
Calculations are based on 105C wire. For lower temperature rated wire, consult the Circuit Wizard at www.circuitwizard.bluesea.com
.25A to 30A
SINGLE WIRE BUNDLED WIRES
1A to 30A
SINGLE WIRE BUNDLED WIRES
30A to 80A
SINGLE WIRE BUNDLED WIRES
30A to 200A
SINGLE WIRE BUNDLED WIRES
30A to 300A
SINGLE WIRE BUNDLED WIRES
100A to 300A
SINGLE WIRE BUNDLED WIRES
225A to 400A
SINGLE WIRE BUNDLED WIRES
35A to 400A
SINGLE WIRE BUNDLED WIRES
16 AWG 14 AWG 12 AWG 10 AWG 8 AWG 6 AWG 4 AWG 2 AWG 1 AWG 0 AWG 2|0 AWG 3|0 AWG 4|0 AWG
25A 20A 20A 15A 25A 20A 20A 15A 30A 25A 20A 30A 25A 30A 25A 20A 30A 30A 30A 25A 50A 40A 30A 30A 30A 50A 40A 30A 30A 30A 50A 40A 30A 35A 50A 40A 40A 35A 80A 60A 50A 40A 130A 100A 70A 60A 150A 130A 100A 80A 200A 175A 150A 130A 250A 200A 175A 150A 300A 250A 200A 175A 350A 300A 225A 200A
60A 50A 40A 40A 60A 50A 40A 40A 60A 50A 40A 40A 80A 70A 60A 50A 80A 70A 60A 50A 80A 70A 60A 50A 80A 70A 125A 100A 80A 70A 125A 100A 80A 70A 125A 100A 150A 125A 125A 100A 150A 125A 125A 100A 150A 125A 125A 100A 200A 175A 150A 125A 200A 175A 150A 125A 200A 175A 150A 125A 200A 175A 150A 250A 200A 175A 150A 250A 200A 175A 150A 250A 200A 175A 300A 250A 200A 175A 300A 250A 200A 175A 300A 250A 300A 225A 200A 250A 225A 300A 250A 300A 225A 200A 350A 300A 225A
AW G W I R E S I Z E
250A 225A 400A 350A 250A 225A 400A 350A 250A 225A 300A 250A 400A 400A 300A 250A 400A 400A 300A 250A
AGA
GMA
AGC/MDL
ATM
ATO/ATC
MAXI
AMI/MIDI
MEGA/AMG
MRBF Terminal
Class-T
ANL
125
APPENDIX
A B
Using the same colored headings as in the FUSE SELECTION CHART (step 2), follow the columns down to find fuse holders or fuse blocks that meet your specific requirements. Consider environmental factors: Ignition protection is required where flammable vapors may accumulate.
Example: Engine room and propane locker Consult American Boat and Yacht Council (ABYC) E-11.5.3 for Ignition Protection
Ignition protection Ingress protection protects fuses from spray, washdown, and humidity. IP66-protected against powerful water jets Ingress protection
Decide between an in-line fuse holder or a fuse block: In-line fuse holders are compact and hold a single low-amperage fuse. Fuse blocks mount to a solid surface and may hold a single fuse or multiple fuses.
5060
5064 064
7720
5191
5001
5502
5005
5062
Although this process uses information from ABYC E-11 to recommend wire size and circuit protection, it may not
7725 7748
5063
cover all of the unique characteristics that may exist on a boat. If you have specic questions about your installation please consult an ABYC certied installer.
7727
LEGEND
Ingress protection Ignition protection
Copyright 2012 Blue Sea systems Inc. All rights reserved. Unauthorized copying or reproduction is a violation of applicable laws.
126
20008 You Can Do it, Protect Your Boat with the Correct Size Wire, Fuse, and Fuse Holder 20 guides per pack
See page 128 for other You Can Do It Guides and marketing materials.
AC
Sources of AC power, whether shore power or onboard generators and inverters, should always have a circuit breaker near the power source. This circuit breaker is designated the AC main circuit breaker. The AC main circuit breaker should always have a pole for each of the hot and neutral wires in the circuit assuring that circuit protection functions are not compromised in reverse polarity situations. Beginning in July 2010 ABYC Standards require that an Equipment Leakage Circuit Interrupter (ELCI) with a 30mA leakage trip be installed in shore power applications as the first protective device after the power inlet. ELCIs respond to leakage of electrical current outside of the intended current path, and provide overload and short circuit protection. They serve as the main AC circuit breaker for the system. These devices will open all energized conductors and the neutral when opened manually or tripping on an overload or leakage fault. For a more complete discussion of ELCIs, see page 5455. 120 Volt60 Hz
APPENDIX
AC Wire Systems
The three most common AC systems used on boats are shown here. In all cases the ground, sometimes called safety ground to clarify its purpose and differentiate it from the DC ground or negative, is said to be a normally non-current carrying wire. Its purpose is to provide the lowest resistance path for AC currents that have strayed from their proper containment in the normally current carrying hot and neutral wires. The ground wire is connected to the exterior conductive parts of AC devices that could be touched by a person during normal operation, and it conducts errant AC currents safely to ground rather than passing them through a human body. The ground wire is never passed through a circuit breaker. 120 Volt60 Hz
Hot Neutral Ground
ELCI 30A
TEST MONTHLY
120/240 Volt60 Hz
Hot 1 Hot 2 Neutral Ground
230 Volt50 Hz
Hot Neutral Ground
ELCI 30A
TEST MONTHLY
120/240 Volt60 Hz
ELCI Circuit Breaker 3102
230 Volt50 Hz
RCBO
AC Shore Power Source 120V - 30A 120V - 50A 120/240V - 50A 240V - 50A
127
Marketing Materials
Blue Sea Systems offers sales and marketing materials that assist in the merchandising, promotion, and selection of products. For updated information and new marketing and sales materials, visit bluesea.com/marketing.
20004 20003
2013 Catalog
20010 20" x 17" Deskmat 20013 132 pages 36 catalogs per case Order individually
Panel Guide
Merchandising Plans
20008 Protect Your Boat with the Correct Size Wire, Fuse, and Fuse Holder (20 per pack)
20005 Design and Order a Custom 360 Panel (20 per pack)
20001
Logo Sign
Window Decal
128
Merchandising Plans
Blue Sea Systems provides merchandising plans to assist with organizing the visual presentation of the product. The plans are available in different sizes to suit the needs of the dealer. A sample of the plans is shown on this page. Additional merchandising plans and specific information of each plan is available at: www.bluesea.com/resources/134.
APPENDIX
129
PN
1001 1002 1003 1010 1011 1012 1013 1014 1015 1016 1017 1020B 1021B 1022B 1023B 1024B 1025B 1026B 1027B 1028B 1029B 1030B 1050 1051 1052 1053 1054 1055 1056 1057 1058 1100 1101 1110 1111 1114 1115 1116 1117 1118 1119 1122 1123 1124 1125 1127 1128 1129 1139 1147 1148 1150 1151 1154 1155 1156 1159 1164 1165 1168 1169 1170 1171 1172 1173 1190 1191 1192 1193
PAGE
66 66 66 115 115 115 115 115 115 115 115 107 107 107 107 107 107 107 107 107 107 107 100 100 100 100 100 100 100 100 100 78 80 82 82 84 84 78 79 93 93 80 79 79 78 79 82 82 20 111 111 47 78 78 78 78 79 78 79 91 91 91 91 91 55 90 90 90 90
PN
1194 1200 1201 1202 1203 1204 1205 1206 1207 1208 1209 1210 1211 1214 1215 1216 1217 1218 1219 1221 1222 1223 1224 1225 1226 1227 1228 1229 1230 1231 1232 1233 1325 1331 1341 1406 1408 1412 1450 1452 1455 1456 1457 1459 1461 1463 1464 1472 1473 1474 1475 1477 1478 1479 1479100 1480 1481 1482 1483 1484 1485 1486 1487 1488 1489 1500 1502 1510 1518
PAGE
90 78 80 85 85 92 92 84 84 86 86 82 82 84 84 78 79 92 92 80 80 79 79 78 81 79 82 82 84 86 86 84 105 110 110 20 20 21 78 80 78 78 78 78 79 78 79 111 98 101 102 48 111 111 111 89 88 88 88 88 88 88 89 89 89 90 90 107 111
PN
1519 1800 1801 1810 1811 1820 2001 2002 2003 2010 2011 2016 2016100 2017 2017100 2018 2018100 2019 2020 2101 2102 2103 2104 2105 2107 2126 2127 2128 2129 2130 2131 2132 2133 2134 2135 2136 2137 2138 2139 2140 2141 2142 2143 2145 2146 2151 2155 2201 2202 2203 2204 2300 2301 2302 2303 2304 2305 2306 2307 2312 2314 2315 2402 2404 2406 2408 2410 2502 2504
PAGE
105 104 104 105 105 105 67 67 67 67 67 67 67 67 67 67 67 64 64 67 67 67 65 64 65 64 64 64 46 46 46 46 46 46 46 46 46 47 47 47 47 47 47 111 111 40 111 66 66 66 66 63 63 63 63 62 62 62 63 63 62 62 65 65 65 65 65 65 65
PN
2506 2508 2510 2512 2602 2604 2606 2608 2610 2701 2702 2708 2709 2710 2713 2715 2716 2718 2719 2722 2723 3000 3001 3002 3003 3091 3092 3093 3100 3102100 3103 3104 3106100 3113 3116 3117 3118 3119 3124 3125 3126 3131 4001 4002 4003 4004 4005 4006 4008 4009 4010 4011 4012 4013 4014 4015 4016 4017 4018 4019B 4020B 4026 4027 4028 4029 4031 4100 4111 4112
PAGE
65 65 65 65 65 65 65 65 65 62 62 65 62 62 62 63 63 64 64 62 62 17 17 17 17 55 55 55 55 55 55 55 55 57 57 57 57 57 57 57 57 50 69 69 69 69 69 69 69 69 69 69 69 69 69 69 69 69 69 69 69 116 116 116 116 116 116 111 111
PN
4113 4116 4117 4119 4121 4125 4126 4130 4131 4135 4136 4137 4138 4140 4150 4151 4152 4153 4154 4155 4205 4206 4207 4208 4215 4216 4217 4218 4302 4304 4306 4308 4374 4376 4378 5004 5005 5006 5015 5018 5021 5022 5025 5026 5028 5029 5030 5031 5033 5034 5035 5037 5060 5061 5062 5063 5064 5065 5101 5102 5103 5104 5105 5106 5107 5108 5117 5118 5119
PAGE
110 111 111 111 110 116 116 116 116 46 46 46 113 117 113 113 113 113 113 113 117 117 117 117 117 117 117 117 73 73 73 73 73 73 73 41 41 38 38 38 38 38 39 39 39 39 39 39 39 39 39 39 38 38 38 38 38 38 36 36 36 36 36 36 36 36 37 37 37
INDEX
130
PN
5120 5121 5122 5123 5124 5125 5126 5127 5128 5129 5130 5131 5132 5133 5134 5135 5136 5137 5138 5139 5140 5141 5142 5143 5161 5162 5163 5164 5165 5175 5176 5177 5178 5180 5181 5182 5183 5184 5185 5186 5187 5188 5189 5190 5191 5201 5202 5204 5205 5206 5207 5208 5209 5210 5211 5212 5213 5215 5217 5218 5219 5220 5226 5227 5228 5229 5230 5231 5232
PAGE
37 37 37 37 37 37 37 37 37 37 37 37 37 37 37 37 37 37 35 35 35 35 35 35 37 37 37 37 37 36 36 36 36 36 36 36 36 36 36 36 36 36 36 36 40 34 34 34 34 34 34 34 34 34 34 34 34 34 34 34 34 34 34 34 34 34 34 34 34
PN
5233 5234 5235 5236 5237 5238 5239 5240 5241 5242 5243 5244 5245 5246 5250 5251 5252 5253 5254 5255 5256 5257 5258 5259 5260 5270 5271 5272 5273 5274 5275 5280 5281 5282 5283 5284 5285 5286 5287 5288 5289 5502 5503 5510e 5511e 6005 6005200 6006 6006200 6007 6007200 6010 6010200 6011 6011200 6337 7035 7036 7037 7038 7039 7040 7041 7042 7043 7044 7045 7046 7047
PAGE
34 34 35 35 35 35 35 35 35 35 35 35 35 35 36 36 36 36 36 36 36 36 36 36 36 35 35 35 35 35 34 34 34 34 34 34 34 35 35 35 35 41 41 16 16 15 15 15 15 15 15 15 15 15 15 89 49 49 49 49 49 49 49 49 49 49 49 49 49
PN
7048 7049 7050 7052 7053 7054 7055 7056 7057 7058 7059 7061 7080 7081 7082 7083 7084 7085 7086 7087 7088 7089 7098 7135 7136 7137 7138 7139 7140 7141 7142 7143 7144 7145 7146 7147 7148 7149 7180 7181 7182 7183 7184 7185 7186 7187 7188 7189 7198 7200 7201 7202 7204 7205 7206 7208 7209 7210 7212 7213 7214 7216 7217 7218 7220 7221 7222 7224 7225
PAGE
49 49 46 46 46 46 46 46 46 46 46 46 48 48 48 48 48 48 48 48 48 48 48 49 49 49 49 49 49 49 49 49 49 49 49 49 49 49 48 48 48 48 48 48 48 48 48 48 48 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50
PN
7226 7228 7229 7230 7232 7233 7234 7235 7236 7237 7238 7239 7240 7241 7242 7244 7246 7248 7250 7250i 7251 7254 7256 7258 7260 7267 7268 7269 7270 7271 7287 7288 7289 7290 7294 7295 7299 7347 7348 7349 7350 7351 7352 7353 7354 7355 7365 7372 7400 7401 7402 7403 7404 7405 7406 7407 7408 7410 7411 7412 7413 7414 7415 7416 7417 7425 7427 7428 7429
PAGE
50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 52 52 52 52 52 52 52 52 52 50 52 52 52 52 52 52 52 52 52 50 50 50 50 50 50 52 52 52 52 52 52 52 91 51 51 51 51 51 51 51 51 51 51 51 51 51 51 51 51 51 51 51 51 51
PN
7430 7433 7475 7476 7477 7480 7481 7482 7483 7484 7485 7490 7491 7492 7493 7494 7495 7504 7506 7507 7508 7509 7518 7519 7521 7522 7540 7541 7542 7543 7544 7545 7546 7547 7548 7549 7554 7560 7561 7562 7563 7564 7565 7566 7568 7570 7571 7572 7573 7574 7575 7576 7577 7580 7581 7582 7583 7584 7585 7586 7588 7601 7610 7611 7620 7620100B 7621 7621100B 7622
PAGE
51 51 53 53 53 110 110 110 110 110 110 110 110 110 110 110 110 11 11 11 11 11 105 10 9 9 53 53 53 53 53 53 53 53 53 53 53 53 53 53 53 53 53 53 53 51 51 51 51 51 51 51 51 53 53 53 53 53 53 53 53 25 26 27 28 28 28 28 28
131
INDEX
PN
7622100B 7623 7623100B 7649 7650 7700 7700100B 7701 7701100B 7702 7702100B 7703 7703100B 7712 7712100B 7714 7714100B 7720 7721 7725 7727 7730B 7731B 7732B 7748 7900 7900200 7901 7901200 7902 7929 7930 7931 7932 7933 7934 7935 7936 7937 7938 7939 8003 8005 8013 8015 8017 8018 8019 8022 8023 8025 8027 8028 8029 8030 8031 8032 8033 8034 8035 8037 8038 8039 8041 8043 8051 8053 8054 8058
PAGE
28 28 28 25 26 23 23 22 22 23 23 22 22 23 23 23 23 40 40 42 42 43 43 43 42 15 15 15 15 117 112 112 112 112 112 112 112 112 112 112 112 98 98 102 98 98 98 98 98 78 78 84 98 84 117 117 86 115 115 114 114 98 117 98 84 101 75 75 82
PN
8059 8061 8065 8066 8067 8068 8069 8072 8073 8074 8076 8077 8079 8080 8081 8082 8084 8085 8086 8087 8088 8089 8095 8096 8097 8099 8100 8101 8102 8110 8127 8129 8132 8134 8143 8158 8159 8161 8165 8166 8167 8169 8171 8172 8173 8174 8176 8177 8179 8184 8185 8186 8195 8197 8199 8200 8204 8205 8206 8207 8208 8209 8210 8211 8212 8214 8216 8217 8218
PAGE
82 86 114 115 117 79 114 50 103 85 85 84 84 20 78 79 92 93 93 52 52 52 92 78 82 84 90 90 90 103 84 84 86 115 84 82 82 86 83 115 115 115 115 115 50 85 85 84 84 92 93 93 92 82 84 114 114 114 114 114 114 114 114 114 114 117 113 117 112
PN
8219 8220 8221 8222 8230 8231 8232 8233 8234 8235 8236 8237 8238 8239 8240 8243 8244 8245 8246 8247 8248 8251 8252 8253 8254 8255 8256 8257 8258 8259 8260 8261 8262 8263 8264 8265 8266 8267 8268 8271 8272 8273 8274 8275 8278 8280 8282 8283 8284 8285 8286 8287 8288 8289 8290 8291 8292 8293 8294 8295 8296 8297 8298 8299 8357 8358 8359 8361 8363
PAGE
112 112 112 112 112 112 112 112 112 101 101 102 102 102 98 98 99 99 99 102 101 101 98 98 98 103 103 103 99 112 112 75 75 75 80 83 112 112 112 75 75 75 75 112 112 20 112 112 112 112 112 112 112 112 112 113 112 112 112 112 112 112 112 112 88 88 88 89 89
PN
8365 8366 8367 8369 8371 8372 8373 8374 8375 8376 8377 8378 8379 8380 8381 8382 8383 8384 8385 8386 8401 8402 8403 8405 8406 8407 8408 8409 8410 8411 8412 8458 8461 8462 8464 8465 8466 8467 8475 8478 8479 8480 8485 8488 8489 8496 8498 8499 8505 8506 8507 8508 8509 8511 8512 8561 8562 8564 8565 8566 8567 8575 8578 8579 8580 8585 8588 8589 8596
PAGE
88 88 88 89 75 75 75 75 79 79 80 80 80 80 81 81 114 114 78 89 78 79 79 84 85 85 93 84 102 82 84 87 83 86 85 85 86 86 87 82 83 82 85 85 86 87 86 86 84 85 85 93 84 82 84 83 86 85 85 86 86 87 82 83 82 85 85 86 87
PN
8598 8599 8686 8689 8690 8693 9001e 9002e 9003e 9004e 9009 9010 9011 9012 9019 9030B 9031B 9038B 9039B 9040B 9041B 9077 9093 9159 9160 9176B 9177B 9216 9217 9218 9228 9230 9233 9353 9354 9630 11001 11003 20003 20004 8331200 8341050 8341060 8341200 8341300 8342200 8342300 8343200 8343300 8344100 8344200 8345100 8345200 8346050
PAGE
86 86 20 21 20 21 16 16 16 16 88 88 88 22 89 69 69 69 69 69 69 89 89 15 28 69 69 65 65 65 103 103 103 99 99 99 16 17 129 129 129 129 129 129 129 129 129 129 129 129 129 129 129 129
INDEX
132
Rating Symbols
Ic
Amperage Continuous Rating Amprage continu Amperaje continuo Amperaggio continuo Amperage Cranking Rating (10 Seconds) Amprage au lancement (10 secondes) Amperaje de potencia de rotacin (10 segundos) Amperaggio alla rotazione del motorino di avviamento (10 secondi) Amperage Cranking Rating (1 Minute) Amprage au lancement (1 min.) Amperaje de potencia de rotacin (1 min.) Amperaggio alla rotazione del motorino di avviamento (1 min.) Amperage Intermittent Rating (5 Minutes) Amprage intermittent (5 min.) Amperaje de potencia intermitente (5 min.) Amperaggio intermittente (5 min.) Amperage Interrupting Capacity Amprage pouvoir de coupure Amperaje potencia de interrupcin Amperaggio capacit di apertura Amperage Maximum Operating Amprage maximum de fonctionnement Amperaje mximo de funcionamiento Amperaggio al funzionamento a pieno carico Amperage Operating Current Courant de fonctionnement en ampres Corriente operativa de amperaje Amperaggio corrente operativ Amperage Trip Reference Rfrence de dclenchement en ampres Referencia de disparo de amperaje Riferimento di attivazione amperaggio Switching Cycles Priodicit de dmarrage Ciclos de conmutacin Cicli di commutazione Temperature Maximum Operating Temprature maximum de fonctionnement Temperatura mxima en funcionamiento Temperatura massima di esercizio
I 10
1 2 3 4 5 6
Rating Example:
12 mm
1
15
I 60
2 3 4 5 6 7 8
Protected against vertically falling drops of water with enclosure tilted up to 15 degrees from the vertical. Limited ingress permitted.
I 300
Protected against sprays of water up to 60 degrees from the vertical. Limited ingress permitted for three minutes.
I ic
Protected against water splashed from all directions. Limited ingress permitted.
I mxo
I oc
Dust Protected. Limited ingress of dust permitted. Will not interfere with operation of the equipment. Two to eight hours.
I tr
Water from heavy seas or water projected in powerful jets shall not enter the enclosure in harmful quantities.
Cs
Tmxo
INGRESS PROTECTION
IP65
Protection against the effects of immersion in water between 15 cm and 1 m for 30 minutes.
Protection against the effects of immersion in water under pressure for long periods.
Tmno
Temperature Minimum Operating Temprature minimum de fonctionnement Temperatura mnima en funcionamiento Temperatura minima di esercizio Voltage Maximum Operating Tension maximum de fonctionnement Voltaje mximo en funcionamiento Tensione massima di esercizio Voltage Minimum Operating Tension minimum de fonctionnement Voltaje mnimo de funcionamiento Tensione minima di esercizio
Example: An IP65 rating can be determined using the above table and example: The first number of the rating example, 6, in the gray column means the enclosure is dust tight The second number of the rating example, 5, in the blue column means the enclosure is protected against jets of water The IP rating system was established by the International Electrotechnical Commission (IEC), an organization for international standards and conformity assessment. The IEC collaborates closely with the International Organization for Standardization (ISO). A complete description of the IP ratings and associated tests is found in IEC Publication 529. Although these ratings were initially developed as a way to classify enclosures, they now provide a convenient, practical way to compare levels of sealing. Many electrical products have an Ingress Protection (IP) rating which identifies the environmental factors needing consideration prior to the products installation. This is important when deciding where to mount products in a dry and clean environment versus a wet and/or dusty environment. The IP rating indicates the degree of protection provided by an enclosure. The numbers following IP represent levels of sealing and can range from no protection to full protection against dust and water. The table provides a description of the protection at each level.
Vmxo
Vmno
Corporate Ofce 425 Sequoia Drive Bellingham, WA 98226 USA p 360.738.8230 p 800.222.7617 Toll Free f 360.734.4195
Florida Ofce 4500 140th Avenue N Suite 117 Clearwater, FL 33762 USA p 727.531.4049 f 727.531.4734
www.bluesea.com conductor@bluesea.com
2012 Blue Sea Systems inc. All rights reserved Unauthorized copying or reproduction is a violation of applicable laws.