Power Modules Technical Data

1.1
1.1.1

Technical data
Technical data, power modules
6SN 11231AA0. 6SN 11241AA0. 6SN 11231AA0. 0HA1 0HA1 Non ventilated 0AA1 0AA1 Non ventilated 0BA1 0BA1 Force ventilated 0CA1 0CA1 Force ventilated 0DA1 0DA1 Force ventilated 0EA1 0EA1 Force ventilated 0FA1 0FA1 0FA1 Force ventilated

Table 1-1: Technical data/power module, 1axis version


Internal Cooling External Cooling Hose Cooling Cooling Type

To use 1FT5 motors with control module 6SN11 180Ax11xxxx Rated current Peak current A A 4 8 7.5 15 12.5 25 25 50 40 80 80 160 100 200

Power loss, total/ internal/external 3)

35 / 14 / 21

45 / 18 / 27 3.3 55

90 / 35 / 55 3.3 55

180 / 62 / 118 3.3 40

300 / 30 / 270 3.3 50

655 / 30 / 625 3.3 55

740 / 90 / 650 3.3 55

kHz X11) %

3.3 55

To use 1FT6 motors/1FK6 motors with control module 6SN11 180Bx11xxxx Rated current Peak current A A 3 6 5 10 9 18 18 36 28 56 56 112 70 140

Power loss, total/ internal/external 3)

35 / 14 / 21

50 / 19 / 31 3.3 55

90 / 35 / 55 3.3 55

190 / 65 / 125 3.3 40

300 / 30 / 270 3.3 50

645 / 25 / 620 3.3 55

730 / 90 / 640 3.3 55

kHz X11) %

3.3 55

To use 1FT6 motors/1FK6 motors/1FN motors with control module 6SN11 180Dx11xxxx, 6SN11 18xNxxxxxxx Rated current Peak current A A 3 6 5 10 9 18 18 36 28 56 56 112 70 140

Power loss, total/ internal/external 3)

35 / 14 / 21

50 / 19 / 31 4 55

90 / 35 / 55 4 55

190 / 65 / 125 4 50

300 / 30 / 270 4 50

645 / 25 / 620 4 55

730 / 90 / 640 4 55

kHz X11) %

4 55

To use 1PH and 1FE1 motors and induction motors with control module 6SN11 210BA11xxxx, 6SN11 220BA11xxxx To use 1PH and 1FE1 motors with control module 6SN11 180Dxxxxxxx Rated current Current for S640% Peak current Power loss, total/ internal/external 3) KH X11) % A A A W 3 3 3 3/12/ 18 3.2 50 5 5 8 40/16/ 24 3.2 50 8 10 16 74 / 29 / 45 3.2 50 24 32 32 260 / 89 / 171 3.2 50 30 40 51 320 / 32 / 288 3.2 50 60 80 102 685 / 30 / 655 3.2 50 85 110 127 850 /100 / 750 3.2 50

Power Modules Technical Data


= inverter clock frequency 1) X1 = reduction factor of the current, current derating from the inverter clock frequency f0 of the power transistors 2) The 1st number is valid for cable lugs, the 2nd number is valid for finelystranded conductors without conn. sleeves. 3) If internal cooling or hose cooling is used, then only Pvtot should be considered. 4) For UL certification: only use copper cables designed for an operating temperature of _60

Power Modules Technical Data Table 1-1: Technical data/power modules, 1axis version
Internal cooling External cooling Hose cooling Cooling type 6SN 11231AA0. 6SN 11241AA0. 6SN 11231AA0. 0HA1 0HA1 Non ventilated To use induction motors with control module 6SN11 180Dxxxxxxx, 6SN11 18xNxxxxxxx Rated current Current A 2.8 4.6 7.4 for S640% Peak current A A 2.8 2.8 4.6 7.3 9.3 14.8 22 39 29 28 37 47 55 73 94 79 102 117 0AA1 0AA1 Non ventilated 0BA1 0BA1 Force ventilated 0CA1 0CA1 Force ventilated 0DA1 0DA1 Force ventilated 0EA1 0EA1 Force ventilated 0FA1 0FA1 0FA1 Force ventilated

Power loss, total/ internal/external 3)

30 / 12 / 18

40 / 16 / 24

74 / 29 / 45

260 / 89 / 171

460 / 19 / 441

685 / 30 / 655

850 / 100 / 750

kHz X11) %

4 55

4 55

4 55

4 50

4 50

4 55

4 55

General data for controlled infeed modules Input voltage Output V 600/625/680 DC voltage Efficiency V 3ph. 0 to 430 V 0.98 Module width Max. crosssection 2)4) mm mm2 50 6/4 50 6/4 50 6/4 50 6/4 100 16/10 150 50 300 95 or 2x35 Weight, approx: Internal cooling External cooling
= inverter clock frequency 1) X1 = reduction factor of the current, current derating from inverter clock frequency f0 of the power transistors (Fig. 4-2) 2) The 1st number is valid for cable lugs, the 2nd number is valid for finelystranded conductors without conn. sleeves. 3) If internal cooling or hose cooling is used, then only Pvtot should be considered. 4) For UL certification: only use copper cables designed for an operating temperature of ;,. 60C.

kg kg

6.5 6.5

6.5 6.5

6.5 6.5

6.5 6.5

9.5 9.5

13 13

26 26

Power Modules Technical Data Table 1-2: Technical data/power module, 1axis version (additional power modules)
Internal cooling External cooling Hose cooling Cooling type 6SN 11231AA0. 6SN 11241AA0. 6SN 11231AA0. 0LA1 0LA1 Force ventilated 0JA1 0JA1 0JA1 Force ventilated 0KA1 0KA1 0KA1 Force ventilated

To use 1FT6 motors/1FK6 motors/1FN motors with control module 6SN11 180Bx11xxxx Rated current Peak current A A 42 64 100 100 140 210

Power loss, total/ internal/external 3)

460 / 25 / 435

1300 / 170 / 1130 3.3 55

1910 / 250 / 1660 3.3 55

kHz X1 1) %

3.3 55

To use 1FT6 motors/1FK6 motors/1FN motors with control module 6SN11 180Dxxxxxxx, 6SN11 18xNxxxxxxx Rated current Peak current A A W Power loss, total/ internal/external 3) kHz X1 1) % 460 / 25 / 435 4 55 1300 / 170 / 1130 4 55 1910 / 250 / 1660 4 55 42 64 100 100 140 210

General data for controlled infeed modules Input voltage Output voltage Efficiency V V 600/625/680 DC 3ph. 0 to 430 V 0.98 Module width Max. crosssection 2)4) mm mm2 150 50 300 95 or 2 x 35 Weight, approx.: Internal cooling External cooling
= inverter clock frequency 1) X1 = reduction factor of the current, current derating from inverter clock frequency f0 of the power transistors (Fig. 4-2) 2) The 1st number is valid for cable lugs, the 2nd number is valid for finelystranded conductors without conn. sleeves. 3) If internal cooling or hose cooling is used, then only Pvtot should be considered. 4) For UL certification: only use copper cables designed for an operating temperature of ;,. 60C.

300 150 or 2 x 50

kg kg

13 13

26 26

28 28

Power Modules Technical Data


Table 1-3 Technical data/power module, 2axis version

Internal Cooling External Cooling Cooling Type

6SN 11231AB0. 6SN 11241AB0.

0HA1 0HA1 Non

0AA1 0AA1 Force

0BA1 0BA1 Force ventilated 12.5 25

0CA1 0CA1 Force ventilated 25 50

ventilated ventilated To use 1FT5 motors with control module 6SN11 180Ax11xxxx Rated current Peak current A A 4 8 7.5 15

Power loss, total/ internal/external 3) fo 1)

70 / 27 / 43

105 / 40 / 64

174 / 67 / 107

364 / 124 / 240

kHz

3.3

3.3

3.3

3.3 55

% 55 55 55 X1 1) To use 1FT6 motors/1FK6 motors with control module 6SN11 180Bx11xxxx Rated current Peak current A A 3 6 5 10 9 18

18 36

Power loss, total/ internal/external 3) fo 1)

70 / 27 / 43

100 / 38 / 62

180 / 69 / 111

380 / 130 / 250

kHz

3.3

3.3 55

3.3 55

3.3 55

% 55 X1 1) To use 1FT6 motors/1FK6 motors/1FN motors

with control module 6SN11 180Dxxxxxxx, 6SN11 18xNxxxxxxx Rated current Peak current A A 3 6 5 10 9 18 18 36

Power loss, total/ internal/external 3) fo 1) X1 1)

70 / 27 / 43

100 / 38 / 62 4 55

180 / 69 / 111 4 55

380 / 130 / 250 4 55

kHz %

4 55

To use 1PH and 1FE1 motors and induction motors with control module 6SN11 18xNxxxxxxx Rated current A 3 3 3 76 / 28 / 48 kHz % 3.2 55 5 5 8 118 / 42 / 76 3.2 55 8 10 16 226 / 74 / 152 3.2 55 24 32 32 538 / 184 / 354 3.2 55 Current for S640% A Peak current Power loss, total/ internal/external 3) fo 1) X1 1) A W

General data for controlled infeed modules Input voltage Output voltage Efficiency V V 600/625/680 DC 3ph. 0 to 430 V 0.98

Power Modules Technical Data


Module width Mm 50 6/4 50 6/4 50 6/4 100 6/4

Max. crosssection 2)4) mm2 Weight, approx.: Internal cooling External kg cooling kg

7 7

7 7

7 7

13.5 13.5

= inverter clock frequency 1) X1 = reduction factor of the current, current derating from inverter clock frequency f0 of the power transistors (Fig. 4-2) 2) The 1st number is valid for cable lugs, the 2nd number is valid for finelystranded conductors without conn. sleeves. 3) If internal cooling or hose cooling is used, then only Pvtot should be considered. 4) For UL certification only use copper cables designed for an operating temperature of _60___

Table 1-4 Order No. assignment Power modules PM type Internal cooling PM 8 A PM 15 A PM 25 A PM 50 A PM 80 A PM 160 A PM 200 A PM 2x8 A PM 2x15 A PM 2x25 A PM 2x50 A 6SN11 23 1AA00 0HA1 6SN11 23 1AA00 0AA1 6SN11 23 1AA00 0BA1 6SN11 23 1AA00 0CA1 6SN11 23 1AA00 0DA1 6SN11 23 1AA00 0EA1 6SN11 23 1AA00 0FA1 6SN11 23 1AB00 0HA1 6SN11 23 1AB00 0AA1 6SN11 23 1AB00 0BA1 6SN11 23 1AB00 0CA1 External cooling 6SN11 24 1AA00 0HA1 6SN11 24 1AA00 0AA1 6SN11 24 1AA00 0BA1 6SN11 24 1AA00 0CA1 6SN11 24 1AA00 0DA1 6SN11 24 1AA00 0EA1 6SN11 24 1AA00 0FA1 6SN11 24 1AB00 0HA1 6SN11 24 1AB00 0AA1 6SN11 24 1AB00 0BA1 6SN11 24 1AB00 0CA1