Vous êtes sur la page 1sur 2

face

1" [25] exp. joint

Depressed pavement

[225]

Curb casting

A
Reinf. steel perSCD BP-1.1

Frame & grate

2" [ 50]

1" [25] exp. joint

4" [100] or height of curb as shown in the plans.

NOTES
GRATE: The Grate "V" shall be provided unless the plans specifically require the diagonal grate. If the diagonal grate is specified, it shall be placed so that the diagonal bars direct drainage flow toward the curb. (See Sht. 2/2.) CASTINGS: The design shall be essentially the same and equally as strong as those shown. Minimum weight [mass]: Curb Casting . . . . . 170 lbs. [77 kg]

" [19] anchor bolt S6x12.5x3-6"1" [S150x18.6x106025] 1" [25] Dowel 1-0" [300] 1-0" [300] 1" [25] Dowel S6x12.5x3-6"1" Permissible constr. joint [S150x18.6 x106025] [300] Var abl depth i e
i n.

Permissible constr. joint

8" [219]

Reinf. steel per SCD BP-1.1

1 2" [ 300] mi . n

1-0"

[ 30 0 ] m

1 1

"[ 292]

REVISIONS

Standard Grate . . . . 127 lbs. [57 kg], Frame . . . . . . . . . 320 lbs. [145 kg], and Grate "V" . . . . . . . 105 lbs. [47 kg]. Lighter weight frames and grates that meet the requirements of CMS 711.14 may also be provided. Grate openings and dimensions shall not differ from

1 2"

7-20-01 7-19-02 7-15-05

The bottom may be precast separately mi . bottom n and the outlet pipe placed on top of it with the bottom shaped to drain.

6" [ 50] 1

The following text shall be cast into the top of the curb casting: "DUMP NO WASTE" and "DRAINS TO WATERWAY" 3" [ 75] Text shall be printed in bold, capital letters with a minimum height of ". See example on Plan (Sht. 2/2). "WATERWAY" may be substituted with "STREAM", "RIVER","LAKE", etc. Actual placement and logo may vary per manufacturer. BEARING AREAS: The frame and grate shall be so fitted and finished as to provide a firm and even seat. No projections shall exist on bearing areas of either casting, and the grate shall seat in its frame without rocking. WALLS: When used in place of concrete, brick side walls shall be 8" [200] nominal thickness. face Cur b PRECAST CONSTRUCTION: Permitted, except for the apron. Concrete shall meet the requirements of CMS 706.13. Precast walls shall have a minimum thickness of 6" [150] and reinforcing shall be sufficient to permit shipping and placement without damage. The wall thickness reduction shall be from the outside. MINIMUM DEPTH: The minimum depth is per the cover requirements for that pipe type. OPENINGS: Any pipe openings greater than 4" [100] from the outside of the pipe to the structure require the Engineers approval. Fill all voids per CMS 604. DOWELS: Four 1"x18" [25x450] dowels are required for concrete pavement or gutter blockout. See SCD BP-2.2 for dowel details. BLOCKOUT: Blockouts shall be paved with Class C concrete in PCC pavement or gutter and paid for as a part of the pavement or gutter with no deduction in pavement, curb or gutter quantities because of the castings. A Class C concrete apron the size of the 2-0" [600] gutter shall be castin-place in asphalt pavement (no dowels required) with the cost included in the catch basin bid price. No deduction to be made in curb quantities.

ALL METRI DI C MENSI ONS

I MI N LLI METERS UNLESS

( I BRACKETS [ ) ARE N ]

B
8" 2-2" [660] 8" [200] 1 Dowel location for curb & gutter 8" [200]

A
2-3" [685] 8" [200]

f cheek

[200]

SECTION A-A
Location of grate elevation, station and offset

SECTION B-B WITH CURB (2" [50] DEPRESSION)

STRUC TURA L C B -2. 2 CA TCH BA SI N N o. 3A

03- OCT- 2008 9: 50AM

Grate (Bicycle Safe Shown) Back of curb Back of curb 1" [25] exp. joint [ 38] " 2-5" [749] 2-0 [600] Gutter

9" [225]

1" [25] Cur b

[ 225]

9"

I \ pr Const ucton Dr : \ r i awi ngs\ SCD\ Hy aul dr i cs\ CB\ cb22_ 07- 1 5- 05_ V8. dgn

X
2 0" [ 600] mi . n

Normal gutter elevation

C
Cap (Typ.) 12" [300] [ 225]

C
[ 38] "

Direction of flow for grate

as shown

45^ 12" Combination curb and gutter blockout [300] 1

Depressed gutter

[ 300]

1 2"

[ 225]

9"

1" [25] Dowel (Typ.)

Outside of conc. basin

9" [225] (Typ.)

9" [225] (Typ.)

Cap

SECTION B-B
Pavement blockout for straight transverse slope

WITH CURB & GUTTER


Butt joint 1" [25] exp. joint

PAYMENT: All materials and labor, including excavation and backfilling, shall be paid for under Item 604 - Catch Basin, No. 3A.

(" [13] DEPRESSION)

B
SCD NUMBER

PLAN OF CATCH BASIN AND PAVEMENT JOINTS


(For SECTIONS C-C and D-D, see Sht. 2/2)

CATCH BASIN No. 3A

STANDARD HYDRAULI CONSTRUCTI C ON DRAWI NG

Location of grate, L elev., sta. and offset

9"

" [ 3] 1

EN G I EERI G N N

O FFI E C

OF

OTHERWI SE NOTED.

3" [ 75]

J Stai s . n

those shown unless otherwise shown in the plans.


ROADWAY HYDRAULI C ENGI NEER

STATE HYDRAULI ENGI C NEER

1" [25]

9"

2" [ 50]

Top of curb

Back of curb Normal pavement slope

STATE OF OHI DEPARTMENT OF TRANSPORTATI O ON

Drop gutter 2" in 20 [50 in 6 m] from each side of catch basin for normal transverse slope, and " [13] within blockout for combined curb and gutter.

Cur b

Location of grate, elev., station and offset

Top of curb and casting

2" [ ] 51

10 bars @ 2" [70] 1" [44] " [3] radii all bar edges

" [16] 2" [70] (Typ.)


STATE OF OHI DEPARTMENT OF TRANSPORTATI O ON

"[ 44]

2-1" [653]

6" [156] (Typ.) 3" [81] (Typ.)

[ 50]

1" [38] (Typ.)

1" [29] (Typ.) 2"

SECTION Y-Y

SECTION D-D
(See Sht. 1/2.) "[ 575]

3" [89] rad.

" [3] rad. 2" [ 50] 2-5" [749] 2" [ ] 51 1" [38] 1" [38]

Direction of flow for grate as shown

1- 0 1

"[ 425]

Y
REVISIONS

[ 9] 1

"

[ 35]

"

14

7-20-01 7-19-02 7-15-05

Grate size 2-5" x 1-4" x 2" 3-2" [965] [749x416x50] " [13] 2-5" [759]
" [ 2 2 ]

DIAGONAL GRATE
(See Sht. 1/2)

GRATE "V"

ALL METRI DI C MENSI ONS

ROADWAY HYDRAULI C ENGI NEER

PLAN

I MI N LLI METERS UNLESS

( I BRACKETS [ ) ARE N ]

16 2-6" [765] " [19] (Typ.) 3" [81] (Typ.) 3" " [ 40] 1
f cheek

3" [75] (Typ.)

1-6" [450] (Typ.)

"[ 7 46 ]

"[ ] 1 9
[ 75] " [19] 1" [32] bolt hole
15 [ " 4 3] 2

1 "[ 2] 9
1" [30] rad. 1" [38] rad.
[ ] 50

1 [5 " 2]

1" [32] (Typ.)

12 -

"[ 7 ] 34
1 "[ 2] 9

STRUC TURA L C B -2. 2 CA TCH BA SI N N o. 3A

"

Finished
2"

03- OCT- 2008 9: AM 51

" [13] rad.

[ 0] 5

2"

9" [243] rad.

[ 9] 1

[ 248]

" [ 9] 1

[ 9] 1

6" [156]

"

2-1" [653]

1" [38] rad. (Typ.)

" [ 9] 1

4" [100] (Typ.)

DUMP NO WASTE

DRAINS TO WATERWAY

1" [44] rad. 4" [100] 2-0" [619]

1" [25]

I \ pr Const ucton Dr : \ r i awi ngs\ SCD\ Hy aul dr i cs\ CB\ cb22_ 07- 1 5- 05_ V8. dgn

(Typ.)

6" [150]

6" [150]

1" [44]
STANDARD HYDRAULI CONSTRUCTI C ON DRAWI NG

BACK VIEW

3-6" [1050]

PLAN

END VIEW FRAME

" [19] (Typ.)

2-6" [765] 2" [50] rad. 1" [32] (Typ.) 3" [81] (Typ.) 6" [150] [ 9] 1 1" [25] rad. (Typ.) " 2-6" [762] 6" [150] 1" [32] rad. (internal) " [19] [ 9] 1 " 9" [248] 5" [133] 1" [25] rad. " [13] rad.

[ 91 1 ]

"

[ 9] 1

2" [ 50]

" [19] 1" [38] rad. 6" [150]

" [ 9] 1

1" [32] rad. (Typ.) 4" [100] (Typ.) 3-2" [965]

Finished 3-6" [1050]

1-6" [450] (Typ.)

3" [75] (Typ.)

3" [75] 1" [32] bolt hole


SCD NUMBER

FRAME
FRONT VIEW

FRONT VIEW

END VIEW

CURB CASTING

CURB CASTING

[ 00] 1

"

4"

[ 40] 1

"

" [13] rad. (Typ.)

EN G I EERI G N N

[ 33] 1

1 3" [ 381 ]

O FFI E C

[ 91 1 ]

"

"

"

OF

OTHERWI SE NOTED.

J Stai s . n

PLAN

SECTION C-C

[ 35]

"

STATE HYDRAULI ENGI C NEER

^ 60

Vous aimerez peut-être aussi