anchors (typ.) Upper box may be precast or cast-in-place (as shown). If precast, set in a bed of mortar.

20:1 slope

8" [200]

2-8" [815]

8" [200] 1" [25]

3" [85] 8" [200] 2-8" [815] 8" [ 35] 1 " [200]

A
1" [25]
21 1:

B
1"x1"x" [25x25x6] (min.) pedestal angle

: 81
6" [150] Bedding Bar 8" of #57 Aggregate Var abl depth i e [ 200]

a B r
Strap 3"x2"x" [75x64x10] angle

Strap

Angle

6" [150] Bedding of #57 Aggregate Outlet pipe

Bottom slab may be precast separately and the outlet placed on top of it with the bottom shaped to drain.

1"x1"x" [25x25x6] (min.) pedestal angle 6" [150] Bedding of #57 Aggregate Outlet pipe

REVISIONS

7-20-01 7-19-02 7-15-05

[ 50] 1

See Sht. 2/2 for NOTES

SECTION A-A

SECTION B-B

f cheek

" [6] min. clearance between grate and frame at upper edge

GRATE "B"

2" [65]

Ten-" bars at 3" c/c (27") [Ten 116 bars at 75 c/c (675)]

2" [65]

STRUC TURA L C B -3. 2

03- OCT- 2008 9: 56AM

8" [200]

2-8" [815]

8" [200]

GRATE "A" 3" [90]

Six-1" bars at 5" c/c (25") [Six 25 bars at 125 c/c (625)] Bar

3" [90]

Angle " [ 70]

[ 200]

8"

[6]

[6] [6] Str ap

31"x 2"x" [805x70x130] Strap ENLARGED SCALE

I \ pr Const ucton Dr : \ r i awi ngs\ SCD\ Hy aul dr i cs\ CB\ cb32_ 07- 1 5- 05_ V8. dgn

Bar

SECTION THRU GRATE


2 8" [ 5] 81

"[ 85]

2" [70] strap

C
[6]

[ 200]

C B
[6] 2 [50] 1"x1"x" [25x25x6] (min.) pedestal angle (Typ.)

8"

6] "[ 4

" [10]

3" [75]

(6" [150] min. Precast)

CATCH BASIN No. 5

SECTION C-C
1 2

SCD NUMBER

PLAN OF CATCH BASIN

3"x2"x" [75x64x10] by 33" [838] angle

8" [200] Normal

NOTE: 1"x1"x" [25x25x6] pedestal angles not shown

CA TCH

37"x2"x" [950x70x13] strap

BA SI N

Str ap

Notch strap over angle seat

N o. 5

Outlet pipe

STANDARD HYDRAULI CONSTRUCTI C ON DRAWI NG

EN G I EERI G N N

O FFI E C

OF

OTHERWI SE NOTED.

Permissible const. joint

Permissible const. joint

I MI N LLI METERS UNLESS

( I BRACKETS [ ) ARE N ]

ALL METRI DI C MENSI ONS

[ 50] 1

6"

J Stai s . n

6"

ROADWAY HYDRAULI C ENGI NEER

STATE HYDRAULI ENGI C NEER

spacing or ferrule loop with partial depth resin bonded

STATE OF OHI DEPARTMENT OF TRANSPORTATI O ON

"x6" [16x150] bolt insert per CMS 712.01 at 18" [450]

Di tch Er osi on Pr otecti on

NOTES
Concrete apron finished to match slope Catch basin GRATE AND FRAME: Shall be of structural steel in accordance with CMS 711.01 and 513. The design shall be essentially the same and equally as strong as the one shown. Rounded 150 [50 m] GRATE: Shall be depressed 3" [75] below the upstream end of the concrete apron at the centerline of the ditch. Unless Grate "B" is specifically required by the plans, Grate "A" shall be furnished and installed. WALLS: Brick or cast-in-place walls shall have a nominal thickness Centerline of ditch of 8" [200] from the bottom slab to the upper box. PRECAST CONSTRUCTION: Permitted, except for the apron. Concrete shall meet the requirements of CMS 706.3. Precast walls shall have a minimum thickness of 6" [150] and reinforcing shall be sufficient to permit shipping and placement without damage. ness reduction shall be from the outside. The wall thick-

STATE OF OHI DEPARTMENT OF TRANSPORTATI O ON

7 6" [ 25 m] mi . 2. n

Ditch Erosion Protection

5 [1.5 m]

7 [2 m] min. To center of earth dike

PLAN

STEPS: Steps meeting the requirements of MH-1 SCD shall be provided where the depth exceeds 6 [1.8 m]. BASINS OVER 12 FEET [3.5 m] IN DEPTH: Shall be precast or cast-inplace concrete; reinforced with #4 [#13M] bars on 12" [300] centers both vertically and horizontally with 2" [50] clearance from inside wall face.

REVISIONS

7-20-01 7-19-02 7-15-05

150 [50 m]

7 [2 m] min. To center of earth dike 5 [1.5 m]

Flowline of ditch [ 75] Rounded 6" [150] Dike unless otherwise noted 3"

ALL METRI DI C MENSI ONS

I MI N LLI METERS UNLESS

( I BRACKETS [ ) ARE N ]

CONCRETE APRONS: Aprons are to be constructed in such a manner that the outside edges are at equal elevation. If specified in the plans, grouted riprap may be used in place of the concrete apron. Concrete apron with cutoff wall 12:1 Slope or flatter DITCH PROTECTION: Provide a 150 [50 m] length of ditch erosion protection as shown. Installation and payment for ditch erosion protection shall comply with CMS 670. BASINS IN SAG: When in a sag, omit the earth dike and longitudinal slope of the grate, and provide concrete apron and ditch protection on each side of the basin. VERTICAL SCALE DISTORTED PAYMENT: The concrete apron with cutoff wall or grouted riprap and dike shall be considered incidental to 604 - Catch Basin, Item No. 5. However, the apron is not required when Item 604 - Catch Basin, No. 5 without Apron, specified. is When itemized separately, payment for Item 601 Riprap using 6" Reinforced Concrete Slab shall include the cost of the cutoff wall.

Ditch Erosion Protection


f cheek

STRUC TURA L C B -3. 2

03- OCT- 2008 9: 56AM

PROFILE ROADSIDE DITCH GRADING AT CATCH BASIN

I \ pr Const ucton Dr : \ r i awi ngs\ SCD\ Hy aul dr i cs\ CB\ cb32_ 07- 1 5- 05_ V8. dgn

STANDARD HYDRAULI CONSTRUCTI C ON DRAWI NG

10 [3.0 m]

[600]

[600]

1 %

% 1

9" [225]

Ditch Centerline

Concrete apron

2 6" [ 750]

6" [150]

UPSTREAM END VIEW OF CONCRETE APRON OR GROUTED RIPRAP

Cutoff wall

6" [150] Reinforced concrete slab

Undisturbed soil
SCD NUMBER

CONSTRUCTION INFORMATION Typical weight [mass] of grate = 185 lbs. [84 kg] Typical weight [mass] of frame = 60 lbs. [27 kg]

9" [225]

RIPRAP CUTOFF WALL DETAIL

CA TCH 2

BA SI N

8:1 slope, or as shown

2-0"

2-0"

e l a ib V ra lp So e

As per CMS 601.04.D, reinforce the slab approximately midway between the top and bottom of the slab, with steel bars or fabricated reinforcement equivalent to #3 [#10M] round bars, at 24" [600] o.c. in two directions, or wire fabric according to SCD BP-1.1.

O FFI E C

OF

See RIPRAP CUTOFF WALL DETAIL

N o. 5

EN G I EERI G N N

Catch basin

OTHERWI SE NOTED.

OPENINGS: Any pipe openings greater than 4" [100] from the outside of the pipe to the structure require the Engineers approval. Fill all voids per CMS 604.

J Stai s . n

ROADWAY HYDRAULI C ENGI NEER

LOCATION AND ELEVATION: When given on the plans, the location is the center of the grate. The elevation is the lowest point on the grate.

STATE HYDRAULI ENGI C NEER