Académique Documents
Professionnel Documents
Culture Documents
20:1 slope
8" [200]
2-8" [815]
3" [85] 8" [200] 2-8" [815] 8" [ 35] 1 " [200]
A
1" [25]
21 1:
B
1"x1"x" [25x25x6] (min.) pedestal angle
: 81
6" [150] Bedding Bar 8" of #57 Aggregate Var abl depth i e [ 200]
a B r
Strap 3"x2"x" [75x64x10] angle
Strap
Angle
Bottom slab may be precast separately and the outlet placed on top of it with the bottom shaped to drain.
1"x1"x" [25x25x6] (min.) pedestal angle 6" [150] Bedding of #57 Aggregate Outlet pipe
REVISIONS
[ 50] 1
SECTION A-A
SECTION B-B
f cheek
" [6] min. clearance between grate and frame at upper edge
GRATE "B"
2" [65]
Ten-" bars at 3" c/c (27") [Ten 116 bars at 75 c/c (675)]
2" [65]
8" [200]
2-8" [815]
8" [200]
Six-1" bars at 5" c/c (25") [Six 25 bars at 125 c/c (625)] Bar
3" [90]
[ 200]
8"
[6]
I \ pr Const ucton Dr : \ r i awi ngs\ SCD\ Hy aul dr i cs\ CB\ cb32_ 07- 1 5- 05_ V8. dgn
Bar
"[ 85]
C
[6]
[ 200]
C B
[6] 2 [50] 1"x1"x" [25x25x6] (min.) pedestal angle (Typ.)
8"
6] "[ 4
" [10]
3" [75]
SECTION C-C
1 2
SCD NUMBER
CA TCH
BA SI N
Str ap
N o. 5
Outlet pipe
EN G I EERI G N N
O FFI E C
OF
OTHERWI SE NOTED.
( I BRACKETS [ ) ARE N ]
[ 50] 1
6"
J Stai s . n
6"
NOTES
Concrete apron finished to match slope Catch basin GRATE AND FRAME: Shall be of structural steel in accordance with CMS 711.01 and 513. The design shall be essentially the same and equally as strong as the one shown. Rounded 150 [50 m] GRATE: Shall be depressed 3" [75] below the upstream end of the concrete apron at the centerline of the ditch. Unless Grate "B" is specifically required by the plans, Grate "A" shall be furnished and installed. WALLS: Brick or cast-in-place walls shall have a nominal thickness Centerline of ditch of 8" [200] from the bottom slab to the upper box. PRECAST CONSTRUCTION: Permitted, except for the apron. Concrete shall meet the requirements of CMS 706.3. Precast walls shall have a minimum thickness of 6" [150] and reinforcing shall be sufficient to permit shipping and placement without damage. ness reduction shall be from the outside. The wall thick-
7 6" [ 25 m] mi . 2. n
5 [1.5 m]
PLAN
STEPS: Steps meeting the requirements of MH-1 SCD shall be provided where the depth exceeds 6 [1.8 m]. BASINS OVER 12 FEET [3.5 m] IN DEPTH: Shall be precast or cast-inplace concrete; reinforced with #4 [#13M] bars on 12" [300] centers both vertically and horizontally with 2" [50] clearance from inside wall face.
REVISIONS
150 [50 m]
Flowline of ditch [ 75] Rounded 6" [150] Dike unless otherwise noted 3"
( I BRACKETS [ ) ARE N ]
CONCRETE APRONS: Aprons are to be constructed in such a manner that the outside edges are at equal elevation. If specified in the plans, grouted riprap may be used in place of the concrete apron. Concrete apron with cutoff wall 12:1 Slope or flatter DITCH PROTECTION: Provide a 150 [50 m] length of ditch erosion protection as shown. Installation and payment for ditch erosion protection shall comply with CMS 670. BASINS IN SAG: When in a sag, omit the earth dike and longitudinal slope of the grate, and provide concrete apron and ditch protection on each side of the basin. VERTICAL SCALE DISTORTED PAYMENT: The concrete apron with cutoff wall or grouted riprap and dike shall be considered incidental to 604 - Catch Basin, Item No. 5. However, the apron is not required when Item 604 - Catch Basin, No. 5 without Apron, specified. is When itemized separately, payment for Item 601 Riprap using 6" Reinforced Concrete Slab shall include the cost of the cutoff wall.
I \ pr Const ucton Dr : \ r i awi ngs\ SCD\ Hy aul dr i cs\ CB\ cb32_ 07- 1 5- 05_ V8. dgn
10 [3.0 m]
[600]
[600]
1 %
% 1
9" [225]
Ditch Centerline
Concrete apron
2 6" [ 750]
6" [150]
Cutoff wall
Undisturbed soil
SCD NUMBER
CONSTRUCTION INFORMATION Typical weight [mass] of grate = 185 lbs. [84 kg] Typical weight [mass] of frame = 60 lbs. [27 kg]
9" [225]
CA TCH 2
BA SI N
2-0"
2-0"
e l a ib V ra lp So e
As per CMS 601.04.D, reinforce the slab approximately midway between the top and bottom of the slab, with steel bars or fabricated reinforcement equivalent to #3 [#10M] round bars, at 24" [600] o.c. in two directions, or wire fabric according to SCD BP-1.1.
O FFI E C
OF
N o. 5
EN G I EERI G N N
Catch basin
OTHERWI SE NOTED.
OPENINGS: Any pipe openings greater than 4" [100] from the outside of the pipe to the structure require the Engineers approval. Fill all voids per CMS 604.
J Stai s . n
LOCATION AND ELEVATION: When given on the plans, the location is the center of the grate. The elevation is the lowest point on the grate.