Académique Documents
Professionnel Documents
Culture Documents
1" [25]
[70x25] Bar
A
2 : 01
21 1: : 81
be a l ai V r
anchors (typ.)
61 :
B
6" [150] Bedding
: 61
2
[ 200] 8"
of #57 Aggregate 6" [150] Bedding of #57 Aggregate 2"x" [70x12.7] Strap 2"x" [70x13] Strap Upper box may be precast or cast-in-place. If precast, set in a bed of mortar. Permissible construction joint Outlet pipe Bottom slab may be precast separately and the outlet placed on top of it with the bottom shaped to drain [ 50] 1 6" 6" [ 50] 1 Var abl Depth i e
REVISIONS
A
8" [200] 2-8" [815] 8" [200]
J Stai s . n
I MI N LLI METERS UNLESS
ROADWAY HYDRAULI C ENGI NEER
B
8" [200] 2-8" [815] 8" [200]
( I BRACKETS [ ) ARE N ]
SECTION A-A
See Sht. 2/2 for NOTES 2" [50] Four Bars at 4" [100] c/c 2" [54]
f cheek
" [11] Angle to be notched, bent and welded " [6] min. clearance between grate and frame at upper edge
8" [200]
2-8" [815]
8" [200]
[6] [6]
8"
Angle
[ 200]
I \ pr Const ucton Dr : \ r i awi ngs\ SCD\ Hy aul dr i cs\ CB\ cb33_ 07- 1 5- 05_ V8. dgn
A
2 8" [ 5] 81 Notch strap over angle seat 2" [70] strap
" x
Outlet Pipe
"[ 85]
6] "[ 4
8"
[6]
2 [50]
[ 200]
" [10]
3" [75]
C
1"x1"x" [25x25x6] (min.) pedestal angle (Typ.) Angle to be notched, bent and welded
B
8" [200] Normal
SCD NUMBER
CA TCH 2
BA SI N
N o. 8
EN G I EERI G N N
O FFI E C
"
[ 70]
OF
OTHERWI SE NOTED.
SECTION B-B
7 6" [ 25 m] mi . 2. n
NOTES
Concrete apron finished to match slope Catch basin Rounded 150 [50 m] GRATE AND FRAME: Shall be of structural steel in accordance with CMS 711.01 and 513. The design shall be essentially the same and equally as strong as the one shown. GRATE: Grate shall be depressed 3" [75] below the upstream end of the concrete apron at the centerline of the ditch. WALLS: Brick or cast-in-place walls shall have a nominal thickness of 8" [200] from the bottom slab to the upper box. PRECAST CONSTRUCTION: Permitted, except for the apron, Concrete shall meet the requirements of CMS 706.13. Precast walls shall have a minimum thickness of 6" [150] and reinforcing shall be sufficient to permit shipping and placement without damage. The wall thickness reduction shall be from the outside. STEPS: Steps meeting the requirements ofMH-1.1 SCD shall be provided where the depth exceeds 6 [1.8 m]. BASINS OVER 12 FEET [3.5 m] IN DEPTH: Shall be precast or cast-in-place concrete; reinforced with #4 [#13M] bars on 12" [300] centers both vertically and horizontally with 2" [50] clearance from inside wall face. LOCATION AND ELEVATION: When given on the plans the location 150 [50 m] 7 [2 m] min. to center of earth dike 5 [1.5 m] Rounded [ 75] Flowline of ditch 3" 6" [150] Dike unless otherwise noted OPENINGS: Any pipe openings greater than 4" [100] from the outside of the pipe to the structure required the Engineers approval. Fill any voids per CMS 604. CONCRETE APRONS: Aprons are to be constructed in such a manner that the outside edges are at equal elevation. If specified in the plans, grouted riprap may be used in place of the concrete apron.
REVISIONS
7-20-01
PLAN
7-19-02 7-15-05
( I BRACKETS [ ) ARE N ]
12:1 Slope or flatter Concrete apron with cutoff wall Catch basin See RIPRAP CUTOFF WALL DETAIL
DITCH PROTECTION: Provide a 150 [50 m] length of ditch erosion protection as shown. Installation and payment for the ditch erosion protection shall comply with CMS 670. BASINS IN SAG: When in a sag, omit the earth dike and longitudinal slope of grate, and provide concrete apron and ditch protection on each side of the basin. PAYMENT: The concrete apron with cutoff wall or grouted riprap and dike shall be considered incidental to Item 604 - Catch Basin, No. 8. However, the apron is not required when Item 604 - Catch Basin, No. 8, Without Apron is specified. When itemized separately, payment for Item 601 Riprap using 6" Reinforced Concrete Slab shall include the cost of the cutoff wall.
I \ pr Const ucton Dr : \ r i awi ngs\ SCD\ Hy aul dr i cs\ CB\ cb33_ 07- 1 5- 05_ V8. dgn
As per CMS 601.04.D, reinforce the slab approximately midway between the top and bottom of the slab, with steel bars or fabricated reinforcement equivalent to #3 [#10M] round bars, at 24" [600] o.c. in two directions, or wire fabric according to SCD BP-1.1.
2 6" [ 750]
Undisturbed soil
SCD NUMBER
CONSTRUCTION INFORMATION Typical weight [mass] of grate = 245 lbs. [111 kg] Typical weight [mass] of frame = 65 lbs. [29 kg]
9" [225]
CA TCH 2
BA SI N
N o. 8
8-0" [2.5 m]
EN G I EERI G N N
O FFI E C
OF
OTHERWI SE NOTED.
J Stai s . n