GR-Series
POWER SYSTEM PROTECTION GRZ 100 Distance Protection GRL 100 Line Differential Protection GRL 150 Line Differential Protection GRT 100 GRB 100 GRB 150 GRF 100 GRC 100 GRR 100 DISTRIBUTION SYSTEM PROTECTION GRD 110 Overcurrent Protection GRD 130 Under/Overvoltage Protection GRD 140 Directional Overcurrent Protection GRD 150 Feeder Manager Relay
Pilot Wire Protection Transformer Protection Low-Impedance Busbar Protection High-Impedance Differential Frequency, Voltage Protection Circuit Breaker Failure Protection Autoreclosing and Synchronism Check
GR-Series
Numerical Protection Relay
POWER SYSTEM PROTECTION
GRZ100 GRL100 GRL150 GRT100 GRB100 GRB150
GRZ100
Distance Protection Line Differential Protection Line Differential Protection (Pilot Wire Protection) Transformer Protection Low-Impedance Busbar Protection High-Impedance Differential Frequency, Voltage Protection Circuit Breaker Failure Protection Autoreclosing and Synchronism Check
Overcurrent Protection Under/Overvoltage Protection Directional Overcurrent Protection Feeder Manager Relay
GRD150
FEATURES
Fully numerical protection High performance - High speed operation - Improved selectivity and stability - Multi-functions High reliability - Automatic supervision - Fault Detector (Option) Low cost - Low power consumption - Compact size Metering and recording functions - Metering of electrical values - Fault & Disturbance records - Event records Configurable binary inputs, outputs and
programmable logic Menu-driven human interfaces Two serial ports for a local PC and a remote PC Communication with Substation Automation System IRIG-B port for external clock
PRODUCT LINE-UP GR-Series offers the solution for protection of power transmission and distribution systems.
Multi - Function relays
Type GRZ100 GRL100 GRL150 GRB100 GRT100 Description Distance Protection Line Differential Protection Line Differential Protection Pilot Wire Protection Low-Impedance Busbar Protection Transformer Protection
Simple-Function relays
Type GRB150 GRR100 GRC100 GRF100 Description High-Impedance Differential Autoreclosing and Synchronism Check Circuit Breaker Failure Protection Frequency, Voltage Protection
GR-Series
Features of Multi Function Relays
GRZ100
Application Distance Protection Current Differential Protection Direct F.O. communication Mulutiplexer communication Pilot wire communication Transformer/Reactor Protection Busbar Protection 21 Distance, Phase fault 21N Distance, Earth fault Command Protection PUP, POP, UOP, BOP 87 Phase-segregated differential 87N Zero-sequence differential GPS-based synchronized sampling 87T Current differential with stability against inrush and overexcitation 87H High-set differential overcurrent REF Restricted earth fault 87 Current differential with enhanced stability against CT saturation REF with directional characteristics Check zone element and discriminating zone element 51 Phase fault Time-O/C 51N Earth fault Time-O/C 50 Phase fault O/C 50N Earth fault O/C 67N Directional Earth fault DEF DEF using telecommunication 50BF Breaker Failure Protection 49 Thermal overload 27 Under voltage 59 Over voltage 81 Overfrequency, Underfrequency 24 Overexcitation Out of step trip Switch on to fault Stub Protection Power swing block 27Z Phase selection element Broken conductor detection Inrush currcut detection 85 Direct inter tripping VT failure supervision 79 Autoreclosing (Single, Multi-pole) 25 Synchronism check Zero sequence current elimination Independent Fault detector Fault location Metering & Monitoring Disturbance record Event record Fault record Programmable logic controller (PLC) Front : RS232C Rear : RS485-1 1 Rear : RS485-2 2 Communication port Rear : Fibre Optic 2 Rear : 100BASE-TX 3 Rear : 100BASE-FX 3 IRIG-B port
GRL100
GRL150
GRT100
GRB100
1for communication with RSM for all types or IEC60870-5-103 except GRB100 2for communication with IEC60870-5-103 3for communication with IEC61850
Standard
Model option
Standard
Model option
GRD130
GRD140
GRD150
1for communication with RSM100 for all types or IEC60870-5-103 except GRD150 2for communication with IEC60870-5-103
Standard
Model option 5
GR-Series
APPLICATION EXAMPLES
Transmission line
GRZ100 EHV GRL100 GRB150
GRC100
Breaker failure protection
GRT100
Transformer protection or Reactor protection
GRC100
GRB150
Busbar protection
GRB150
(High-impedance differential)
GRB100
Busbar protection (Low-impedance differential)
GRD110-140
Feeder protections
GRT100
GRT100
GRD150
Feeder manager relay
GRB150
Transmission line
Distribution feeder
HARDWARE
Figure 1 shows the hardware block diagram of the relay. The relay has a multiple microprocessor design. The microprocessors perform the software functions such as signal processing, protection algorithm, scheme logic, output relay control and handling of the human interface. Analog inputs include phase current inputs, residual current inputs and phase voltage inputs. The number of analog inputs depends on the type of the relay. The internal auxiliary transformers are used to isolate, step down and condition the inputs from the VT and CTs. Their output signals are then converted into digital data for further processing. The front panel contains a liquid crystal display (LCD) and pushbutton keys to provide local access to the relay menu. There are also light emitting diodes (LED) for visual indication of the status of the relay. The relay provides three communication ports, RS232C for connection of a local PC, RS485 for a remote PC and IRIG-B for an external clock.
Transformer module
Event Record
Time-tagged events are stored with 1ms resolution. Events recorded are as follows. - Tripping operations - Alarms - Change of state of binary inputs/outputs - Change of relay setting - Failure detected by automatic supervision - Other events defined by user
Fault Record
-LCD Human -LED machine -Operation key interface -RS232C I/F
Local PC
Fig.1 Hardware block diagram The terminal blocks are located at the rear of the relay providing connections for all input and output circuits.
A relay trip initiates fault recording. Records are stored for the 8 most recent faults, time-tagged to 1ms resolution. The fault record is available on the relay fascia LCD and at a local or remote PC. Fault records include the following data: Date and time of trip operation. Operating phase. Protection scheme responsible for trip. Measured current data.
Disturbance Record
The relay can record analog and binary signals initiated by relay tripping. The post-trigger recording time can be set, and the maximum number of records which can be stored is dependent on the recording time chosen.
GR-Series
USER INTERFACE Relay Front Panel
A user friendly interface is provided on the relay front panel. A menu-based system provides for easy programming of relay functions and access to real-time and stored data. The front panel includes LCD with backlight, LEDs, operation keys and RS232C port for a local PC.
Local PC Connection
The user can communicate with the GR-relay from a local PC via the RS232C port on the front panel. Using RSM100 software, the user can view and modify settings, monitor real-time metering and analyse recorded data.
OPTICAL/RS485 INTERFACE
TOSHIBA
TOSHIBA
TOSHIBA
TOSHIBA
32
256
226
225
TOSHIBA
OPTICAL/RS485 INTERFACE
TOSHIBA Metering 1
TOSHIBA Metering 1
TOSHIBA
TOSHIBA
97
98
128
160
130
129
IEC61850 Communication
Some of the relay types can support data communication according to the IEC 61850 standard. Station bus communication as specified in IEC 61850-8-1 facilitates integration of the relays within substation control and automation systems via Ethernet LAN, either 100BASE-TX or 100BASE-FX.
8
PC DISPLAY
Event record
Data analysis
Fault record
PLC editor
Relay Setting
The user can input or change settings using the operation keys on the relay fascia or via a local or remote PC with the RSM system. Password protection is provided to change settings. Four to eight active setting groups are provided. The number of setting groups depends on the relay type.
Binary Inputs
GR-relays provide programmable binary inputs. The number of inputs varies according to the relay type.
PLC Function
Some GR-relays are provided with a PLC (Programmable Logic Control) function allowing user-configurable sequence logics on binary signals. Configurable binary inputs, binary outputs and LEDs are programmed by the PLC function.
9
GR-Series
TYPICAL TECHNICAL DATA
The following data varies according to the relay type. The detailed data could be referred to each brochure of the relay type.
Ratings AC current In: AC voltage Vn : Frequency: DC auxiliary supply: 1A or 5A 100V, 110V, 115V, 120V 50Hz or 60Hz 110/125Vdc (Operative range: 88 - 150Vdc) 220/250Vdc (Operative range: 176 - 300Vdc) 48/54/60Vdc (Operative range: 38.4 - 72Vdc) 24/30Vdc (Operative range: 19.2 - 36Vdc) 12% 50ms at 110V 110/125Vdc (Operative range: 88 - 150Vdc) 220/250Vdc (Operative range: 176 - 300Vdc) 48/54/60Vdc (Operative range: 38.4 - 72Vdc) 24/30Vdc (Operative range: 19.2 - 36Vdc) 0.1VA (1A rating) 0.3VA (5A rating) 0.1VA (1A rating) 0.3VA (5A rating) 10-16W (quiescent) 15-25W (maximum) 0.5W per input at 110Vdc
Binary input circuit: Communication port - local PC (RS232) Point to point Connection: Multi-core (straight) Cable type: 15m (max.) Cable length: RS232C 9pin D-subminiature connector female Connector: Communication port - remote PC (RS485 for IEC60870-5-103 or RSM) Multidrop (max. 32 relays) Connection: Twisted pair cable Cable type: 1200m (max.) Cable length: Screw terminals Connector: 1kVac for 1 min. Isolation: 64kpbs for RSM system Transmission rate: 9.6, 19.2kbps for IEC60870-5-103 Communication port - remote PC (Fibre Optic for IEC60870-5-103) Cable type: 50/125 or 62.5/125 m fibre Cable length: 2km (max.) Connector: ST type connector Transmission rate: 9.6, 19.2kbps for IEC60870-5-103 Communication port - Substation Automation Systems (IEC61850) Ethernet LAN Interface 10BASE-T: RJ-45 connector 100BASE-TX: RJ-45 connector 100BASE-FX: SC connector
RELAY OUTLINE
TYPE GRZ100 GRL100 GRL150 GRB100 GRT100 GRB150 GRR100 GRC100 GRF100 GRD110 GRD130 GRD140 GRD150 DESCRIPTION Distance Protection Line Differential Protection Line Differential Protection (Pilot Wire Protection) Low-Impedance Busbar Protection Transformer Protection High-Impedance Differential Autoreclosing and Synchronism Check Circuit Breaker Failure Protection Frequency, Voltage Protection Overcurrent Protection Under/Overvoltage Protection Directional Overcurrent Protection Feeder Manager Relay RELAY CASE A or B A or B D B A C C C C D D D E
10
VIEW
RISET
266
7 4
A B OV
8 5 2 .
9 6 3
1 0
ENTER
END
CANCEL
254
276.2
32
VIEW
RISET
266
7 4
A B OV
8 5 2 .
9 6 3
1 0
ENTER
END CANCEL
345.4 364
276.2
32
VIEW
ALARM
RISET
258
258
OV
CANCEL ENTER
END
104
15.6
243.5
32
104
15.6
185.2
32
266
REMOTO ENTER
RISET
B OV
END
CANCEL
F1
F2
254
30
205
30
11
GR-Series
The data given in this catalog are subject to change without notice.