LOOP-E E1 CSU/DSU Model 1510 (Stand Alone) USER'S MANUAL

LOOP TELECOMMUNICATION INTERNATIONAL, INC. 8F, NO. 8, HSIN ANN RD. SCIENCE-BASED INDUSTRIAL PARK HSINCHU, TAIWAN Tel: Fax: +886-3-578-7696 +886-3-578-7695

2003 Loop Telecommunication International, Inc. All rights reserved.


Loop-E is a trade mark of Loop Telecommunication International, Inc. P/N: 51.LE1510.1S0 11/2003 Version 1.6

TABLE OF CONTENTS
1. PRODUCT DESCRIPTION ..................................................................1-1
1.1 1.2 1.3 Description ...................................................................................................... 1-1 Applications..................................................................................................... 1-1 Specifications.................................................................................................. 1-4 Site Selection................................................................................................... 2-1 Mechanical and Electrical Installation .......................................................... 2-2 Mechanical Installation......................................................................... 2-2 Electrical Installation ............................................................................ 2-5 DIP Switch Operation for V.35 and X.21 ....................................................... 2-8 DIP Switch Operation for Bridge (Frame) ..................................................... 2-9 DIP Switch Operation for Bridge (Unframe) ............................................... 2-10 LED Operation ............................................................................................... 2-12 DTE Configuration .......................................................................................... 3-1 CRC (Cycle Redundancy Check)......................................................... 3-1 TTM (Terminal Timing Mode) .............................................................. 3-1 Clock Invert .......................................................................................... 3-1 Self-Test ........................................................................................................... 4-1 Diagnostics...................................................................................................... 4-1 Line Loopback...................................................................................... 4-1 DTE to DTE Loopback ......................................................................... 4-1 Verifying Loop-E Operations ......................................................................... 4-1 Quick Test............................................................................................ 4-1 Substitution .......................................................................................... 4-2 Using Loopback Plugs ......................................................................... 4-2 Using Bert Test Set.............................................................................. 4-2

2.

INSTALLATION.....................................................................................2-1
2.1 2.2 2.2.1 2.2.2 2.3 2.4 2.5 2.6

3.

OPERATION .........................................................................................3-1
3.1 3.1.1 3.1.2 3.1.3

4.

MAINTENANCE ....................................................................................4-1
4.1 4.2 4.2.1 4.2.2 4.3 4.3.1 4.3.2 4.3.3 4.3.4

-i-

FIGURES
Figure 1- 1 Application Illustration - 1------------------------------------------------------------------------------------1-1 Figure 1- 2 Application Illustration - 2------------------------------------------------------------------------------------1-2 Figure 1- 3 Application Illustration - 3------------------------------------------------------------------------------------1-2 Figure 1- 4 Application Illustration 4 -----------------------------------------------------------------------------------1-3 Figure 1- 5 Application Illustration - 5------------------------------------------------------------------------------------1-3 Figure 2- 1 Loop-E E1 CSU/DSU Front Panel Views-----------------------------------------------------------------2-2 Figure 2- 2 Rear Panel Views ----------------------------------------------------------------------------------------------2-3 Figure 2- 3 Loop-E 1510 Stand Alone Internal Jumper Setting ----------------------------------------------------2-4 Figure 2- 4 Jumper Setting for Bridge (Unframe)----------------------------------------------------------------------2-5 Figure 2- 5 DIP Switch on Rear Panel (For V.35 and X.21) --------------------------------------------------------2-8 Figure 2- 6 DIP Switch on Rear Panel (For Framed Bridge)--------------------------------------------------------2-9 Figure 2- 7 DIP Switch on Rear Panel (For Framed Bridge)------------------------------------------------------ 2-10 Figure 2- 8 DIP Switch on Bottom Side (For V.35 and X.21) ----------------------------------------------------- 2-11

TABLES
Table 2- 1 Loop-E 1510 Stand Alone Configuration ------------------------------------------------------------------2-4 Table 2- 2 Configuration for ridge (Unframe Version) ----------------------------------------------------------------2-5 Table 2- 3 RJ48 Line Connector-------------------------------------------------------------------------------------------2-5 Table 2- 4 V.35/M34 DTE Port Pin Definition---------------------------------------------------------------------------2-6 Table 2- 5 X.21/DB15 DTE Port Pin Definition -------------------------------------------------------------------------2-7 Table 2- 6 RJ-45 for 10/100M Pin Assignment ------------------------------------------------------------------------2-7 Table 2- 7 DIP Switch (SW1 to SW8) Indication on Rear Panel (For V.35 and X.21) -----------------------2-8 Table 2- 8 E1 WANDIP Switch (SW1 to SW5) Indication on Rear Panel (For Framed Bridge)--------2-9 Table 2- 9 E1 WANDIP Switch (SW6 to SW8) Indication on Rear Panel (For Framed Bridge)--------2-9 Table 2- 10 E1 WANDIP Switch (SW3) Indication on Rear Panel (For Unframed Bridge) ------------ 2-10 Table 2- 11 E1 WANDIP Switch (SW6 to SW8) Indication on Rear Panel (For Unframed Bridge) - 2-10 Table 2- 12 DIP Switch Indication on Bottom Side ----------------------------------------------------------------- 2-11 Table 2- 13 Front Panel LED Table------------------------------------------------------------------------------------- 2-12

- ii -

Compliance with :

(1) EMC EMI : EN50081-1 EN55022 (Conduction & Radiation) Class A EMS : EN50082-1 IEC801-2 (ESD, 8KV) ESD: ElectroStatic Discharge Test IEC801-3 (R/S, 27MHZ~500MHZ, 3V/M) R/S: Radiated Susceptibility Test IEC801-4 (EFT, 1KV) EFT: Power, Line/Date, Line Nose Test (2) SAFETY EN 60950

- iii -

CAUTION:

Never install telephone wiring during a lightning storm. Never install telephone jacks in wet locations unless the jack is specifically designed for wet locations. Never touch uninsulated telephone wires or terminals unless the telephone line has been disconnected at the network interface. Use caution when installing or modifying telephone lines. _________________________ Standard Lists _________________________

Loop-E E1 is designed to meet the following standards: ITU G.703, G.704, G.706, G.732, G.736, G.823, ETSI ETS 300420, and ETS300419.

- iv -

Chapter 1 Production Description

1. PRODUCT DESCRIPTION
1.1 Description
Loop-E 1510 provides E1 network interface, DS0 channel multiplexing, and direct connections to data, and video DTE (Data Terminal Equipment). This manual applies only to the Stand-Alone model. Loop-E 1510 also supports framed/unframed E1-to-Ethernet Bridge, provides an economic solution to E1 network access. The E1-to-Ethernet Bridge supports fractional or clear channel E1 WAN port with HDB3 (High Density Bipolar 3) coding and continuous error checking, and single 10/100 Ethernet LAN port with bridging function. Loop-E E1 CSU/DSU can be configured via the DIP switches.

1.2 Applications
The Loop-E E1 CSU/DSU application example is illustrated in Figure 1-2. Via DACS (Digital Access CrossConnect System), the Loop-E interfaces various applications such as LAN (Local Area Network) to WAN (Wide Area Network) communications, Host to workstation communications, video conferencing and data communication of PBXs (Private Branch Exchanges). This allows the user to integrate different application into a single communication link and utilizing only part of the available bandwidth. Furthermore, this allows the user to expand bandwidth, up to 31 DS0 channels, on demand without additional physical links because they are already available. Data and video applications may include equipment such as video conferencing, bridge, router, gateway, workstation, host computer, and various high-speed data terminal equipment. Figure 1-3 to Figure 1-5 illustrates some of these applications.

Fractional E1 Network & Services


Digital CrossConnect Digital CrossConnect

Bridge/ Router

Loop-E

Digital CrossConnect

Loop-E

Video Conference

Video Conference

Loop-E

Loop-E

CAD/ CAM

CAD/ CAM

Loop-E

Figure 1- 1 Application Illustration - 1

1-1

Chapter 1 Product Description

E1

E1

Loop-E

Loop-E

Bridge/ Router

Bridge/ Router

Figure 1- 2 Application Illustration - 2 E1

Loop-E

Loop-E

Bridge/ Router

Bridge/ Router

Figure 1- 3 Application Illustration - 3

1-2

Chapter 1 Product Description

Loop-E

E1

Loop-E

CLUSTER CONTROLLER

HOST COMPUTER

Figure 1- 4 Application Illustration 4

Branch Office or SMB E 1510 10/ 100 BaseT E1 Router Bridge WAN

LAN

Figure 1- 5 Application Illustration - 5

1-3

Chapter 1 Product Description

1.3 Specifications
Network Line Interface (E1 Interface) Line Rate 2.048 Mbps 50 ppm Line Code HDB3 Input Signal ITU G.703 Jitter ITU G.823 Framing ITU G.704 Connector BNC/RJ48C (specify on order) Output Signal ITU G.703 Electrical 75 Coax/120 twisted pair DTE Interface (V.35) Data Port Single DTE Data Rate n 64 Kbps ( n = 1 - 32) Connector M34 DTE Interface (X.21) Data Port Single DTE Data Rate n 64 Kbps ( n = 1 - 32) Connector DB15 Alarm Relay Alarm Relay, Fuse alarm, and performance alarm Bridge Interface Data Port Single Ethernet Physical Interface 802.3 10BaseT, 802.3u 100BaseTX Connector RJ45 ! Bridge function ! Auto-negotiation Clear Channel (Unframed) Data Rate 2048 Kbps (32 * 64Kbps) Diagnostics Test Loopbacks Line Loopback and DTE Loopback

1-4

Chapter 1 Product Description

Front Panel Multicolor LED Indicator

POWER Loop-E TM E1 CSU/DSU

LINE

DTE

SYNC/TEST LOF

BPV

RAI

CS

TEST

TD

RD CLK-LOSS

E1510 with V.35 Interface

ACO POWER Loop-E TM E1 CSU/DSU LINE DTE

SYNC/TEST LOF

BPV

RAI

CS ALARM/TEST

TD

RD CLK-LOSS

E1510 with X.21 Interface

POWER Loop-E TM
SYNC/TEST LOF

E1 WAN

ETHERNET LAN

BPV

RAI

CS

LINK/ACT

10/100

FDX

E1510 with Bridge Interface (Frame Version)

POWER Loop-E
TM

E1 WAN

ETHERNET LAN

LINK

LINK/ACT

10/100

FDX

E1510 with Bridge Interface (Unframe Version)

Physical/Electrical Dimensions Power Temperature Humidity Mounting Compliance ETSI Pan European BABT ITU EMI/EMC Safety

21 x 14 x 4.15 cm (WxHxD) 100-240Vac, 24Vdc, 48Vdc 0 -50C 0-95% RH (NON-CONDENSING) Desk-top stackable ETS 300420, ETS 300419 CTR 12/13, CE 168X NTR4 G.703, G.704, G.706, G.732, G.736, G.823 EN50082-1, EN55022 Class A EN60950

1-5

Chapter 2 Installation

2. INSTALLATION
CAUTION: Never install telephone wiring during a lightning storm. Never install telephone jacks in wet locations unless the jack is specifically designed for wet locations. Never touch un-insulated telephone wires or terminals unless the telephone line has been disconnected at the network interface. Use caution when installing or modifying telephone lines.

2.1 Site Selection


The following are guidelines for site selection. These guidelines must be followed to ensure a proper installation site. The installation site should have an AC power receptacle. The following are the maximum suggested cable lengths: V.35 X.21 60m 60m (200 ft) (200 ft)

NOTE: If longer distance is desirable, a lower than maximum speed with proper cabling and grounding is advisable. For more information, please contact Loop Service Representative. The installation site should provide space for adequate ventilation and cable routing. Reserve at least 12 cm (5 inches) at the rear of the unit for cables and air flow. The site should provide a stable environment. The operating area should be clean and free from extremes of temperature, humidity, shock, and vibration. Relatively humidity should stay between 0 and 95%. Do not operate the unit at an altitude greater than 3000 meters (10,000 feet).

2-1

Chapter 2 Installation

2.2 Mechanical and Electrical Installation 2.2.1 Mechanical Installation


Loop-E E1 CSU/DSU Stand-Alone version is a desk top unit, which is stackable. The front panel and the rear panel are shown in the following figures.
For V.35

POWER Loop-E TM E1 CSU/DSU

LINE

DTE

SYNC/TEST LOF

BPV

RAI

CS

TEST

TD

RD CLK-LOSS

For X.21
ACO POWER Loop-E E1 CSU/DSU
TM

LINE

DTE

SYNC/TEST LOF

BPV

RAI

CS ALARM/TEST

TD

RD CLK-LOSS

For Bridge (Frame Version)

POWER Loop-E TM
SYNC/TEST LOF

E1 WAN

ETHERNET LAN

BPV

RAI

CS

LINK/ACT

10/100

FDX

For Bridge (Unframe Version)

POWER Loop-E TM

E1 WAN

ETHERNET LAN

LINK

LINK/ACT

10/100

FDX

Figure 2- 1 Loop-E E1 CSU/DSU Front Panel Views

2-2

Chapter 2 Installation

NT-CLK

NORMAL

NORMAL

OFF TTM OFF

OFF

OFF

AC LINE, 100-240VAC

DTE - V.35
E1 RELAY
NC COM NO

RX-IN

TX-OUT

ON 1 2 3 4 5 6 7 8 CRC DTE-LB CLK-INV NORMAL LINE-CLK DTE-CLK

50-60HZ, 0.15A MAX.

NT-CLK

OFF

OFF

AC LINE, 100-240VAC

NORMAL

OFF TTM OFF

DTE-INV

LINE-LB TTM ON

DTE - X.21
RELAY
NC COM NO

E1 RX-IN TX-OUT

ON 1 2 3 4 5 6 7 8 CRC DTE-LB LINE-CLK CLK-INV DTE-CLK

50-60HZ, 0.15A MAX.

POWER (DC 24V)

POWER (DC 48V)

OR
-V +V -V +V

For Bridge (Frame)


AC LINE, 100-240VAC
INT-CLK OFF SW6 SW7 LAN SW8 OFF OFF OFF

DTE-INV

LINE-LB TTM ON

ETHERNET
RX-IN

E1 TX-OUT

ON 1 2 3 4 5 6 7 8
REMOTE-LB

LINE-CLK

LINE-LB

CRC

50-60HZ, 0.15A MAX.

For Bridge (Unframe)


AC LINE, 100-240VAC
SW6 SW7 SW8 OFF LAN

BERT

10/100

ETHERNET
RX-IN

E1 TX-OUT

ON 1 2 3 4 5 6 7 8

50-60HZ, 0.15A MAX.

Figure 2- 2 Rear Panel Views

LINE-LB

10/100

2-3

Chapter 2 Installation

Table 2- 1 Loop-E 1510 Stand Alone Configuration TP (120 ohm) J1 J2 J3 J4 J5 J6 J7 1,2 1,2 1,2 1,2 1,2 1,2 1,2 J1 J2 J3 J4 J5 J6 J7 BNC * (75 ohm) 2,3 (BNC) 2,3 (BNC) 2,3 (BNC) 2,3 (BNC) 2,3 (BNC) 2,3 (BNC) 2,3 (BNC)

Note: When BNC connector is selected, the user has the option of grounding the received BNC shield by installing a jumper clip on the jumper location. This is usually not necessary, but if you have any noise on your device it can often be filtered out by using this grounding process.

Front Side
TP TP TP

Front Side
BNC BNC BNC

1 2 3

1 2 3 JUM3

1 2 3 JUM2

1 2 3

1 2 3 JUM3

1 2 3 JUM2

Main Board for V.35 and Bridge

JUM6

TP (120 ohm)

Main Board for V.35 and Bridge

JUM6

BNC (75 ohm)

Rear Side
3 2 1 JUM7
BNC

Rear Side
1 2 3 JUM1
TP BNC

3 2 1 JUM7
BNC

1 2 3 JUM1
TP BNC

JUM5 3 2 1

JUM4 1 2 3

JUM5 3 2 1 JUM8

JUM4 1 2 3

Front Side

Front Side

1 2 3

1 2 3

1 2 3

1 2 3

1 2 3

BNC

BNC

Main Board for X.21

TP

TP

TP

TP (120 ohm)

JUM2

JUM3

JUM6

Main Board for X.21

BNC (75 ohm)

JUM2

JUM3

Rear Side
3 2 1 JUM7
BNC

Rear Side
1 2 3 JUM1
TP BNC

3 2 1 JUM7
BNC

1 2 3 JUM1
TP BNC

JUM5 3 2 1

JUM4 1 2 3

JUM5 3 2 1 JUM8

JUM4 1 2 3

Figure 2- 3 Loop-E 1510 Stand Alone Internal Jumper Setting

2-4

1 2 3

BNC

JUM6

Chapter 2 Installation

Table 2- 2 Configuration for ridge (Unframe Version) Jumper J10 Internal Clock Setting 1, 2 Line Clock Setting 2, 3 Default Setting 1, 2

Front Side
JUM10 1 2 3

Front Side
JUM10 1 2 3

Main Board ( Internal Setting )


Rear Side

Main Board ( Line Setting )

Rear Side

Figure 2- 4 Jumper Setting for Bridge (Unframe)

2.2.2 Electrical Installation


Loop-E E1 CSU/DSU Stand-Alone version is AC powered. Use the rear right power connector to connect to an AC power outlet. Network connection is supported by RJ48 or BNC connector. The line interface is labeled with LINE. RJ48 connector pin definition is listed in the following table.

Table 2- 3 RJ48 Line Connector Pin Number 1 2 3 4 5 6 7 8 Signal Receive Ring Receive Tip Unassigned Transmit Ring Transmit Tip Unassigned Shield Ground Shield Ground Signal Direction From E1 Network From E1 Network To E1 Network To E1 Network

The DTE port is configured as a DCE device. Pin definitions for V.35/ M34 is defined in the following table.

Note: For the case of balanced twisted pair interface, if the transmit and receive pairs have shields, then only one end of the shields should be connected to earth. If the near end is selected for grounding the shields, the two shield pairs on the RJ48 connector can be used for this purpose.

2-5

Chapter 2 Installation

Table 2- 4 V.35/M34 DTE Port Pin Definition Pin Number A B C D E F H J K L M N P R S T U V W X Y Z AA BB CC DD EE FF HH JJ KK LL MM NN Cable Shield Signal Ground Request To Send Clear To Send Data Set Ready Data Carrier Detect Data Terminal Ready Unassigned Unassigned Local Loopback Unassigned Remote Loopback Transmit Data Receive Data Transmit Data Return Receive Data Return External Clock Receive Clock External Clock Return Receive Clock Return Transmit Clock Unassigned Transmit Clock Return Unassigned Unassigned Unassigned Unassigned Unassigned Unassigned Unassigned Unassigned Unassigned Unassigned Test Mode DCE DCE DTE DTE DCE DTE DCE DTE DCE DTE DCE DCE DTE DTE DCE DCE DCE DTE Signal Source

2-6

Chapter 2 Installation

Table 2- 5 X.21/DB15 DTE Port Pin Definition Pin Number 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 Cable Shield Transmit Data Control Receive Data Indication Signal Timing External Clock Signal Ground Transmit Data Return Control Return Receive Data Return Indication Return Signal Timing Return External Clock Return Unassigned DTE DTE DCE DCE DCE DTE DTE DTE DCE DCE DCE DTE Signal Source

Table 2- 6 RJ-45 for 10/100M Pin Assignment Pin Number 1 2 3 4 5 6 7 8 Signal Transmit Data + Transmit Data Receive Data + No Connection No Connection Receive Data No Connection No Connection Input to E1510 Signal Direction Output from E1510 Output from E1510 Input to E1510

2-7

Chapter 2 Installation

2.3 DIP Switch Operation for V.35 and X.21


Table 2- 7 DIP Switch (SW1 to SW8) Indication on Rear Panel (For V.35 and X.21) Function Direction
" (OFF), " (OFF) SW1, SW2

SW No.

Description Internal clock DTE clcok Line clock Not used CRC off CRC on Disable DTE to DTE loopback Enable DTE to DTE loopback Disable Line loopback Enable Line loopback TTM off TTM on Clock normal Clock invert DTE clock normal DTE clock invert

Default

Clock Source

" (OFF), # (ON) # (ON), " (OFF) # (ON), # (ON)

" (OFF), " (OFF)

SW3

CRC DTE Loopback Line Loopback TTM Clock Invert DTE Clock Invert

" (OFF) # (ON) " (OFF) # (ON) " (OFF) # (ON) " (OFF) # (ON) " (OFF) # (ON) " (OFF) # (ON)

" (OFF)

SW4

" (OFF)

SW5

" (OFF)

SW6

" (OFF)

SW7

" (OFF)

SW8

" (OFF)

INT-CLK

NORMAL CLK-INV

ON 1 2 3 4 5 6 7 8 LINE-CLK DTE-CLK LINE-LB TTM ON CRC DTE-LB DTE-INV

Figure 2- 5 DIP Switch on Rear Panel (For V.35 and X.21)

2-8

NORMAL

OFF TTM OFF

OFF

OFF

Chapter 2 Installation

2.4 DIP Switch Operation for Bridge (Frame)


Table 2- 8 E1 WANDIP Switch (SW1 to SW5) Indication on Rear Panel (For Framed Bridge) Function Clock Source CRC Direction
" (OFF), " (OFF) " (OFF), # (ON) " (OFF) # (ON) " (OFF) SW3

SW No. SW1

Description Internal clock Line clock CRC off CRC on Disable Line loopback Enable Line loopback Disable Remote Loopback Enable Remote Loopback Disable BERT test pattern Enable BERT test pattern

Default
" (OFF), " (OFF)

SW2

" (OFF)

Line Loopback Remote Loopback BERT

# (ON) " (OFF) # (ON) " (OFF) # (ON)

" (OFF)

SW4

" (OFF)

SW5

" (OFF)

Table 2- 9 E1 WANDIP Switch (SW6 to SW8) Indication on Rear Panel (For Framed Bridge) Auto-negotiation 1 1 1 100 Full 0 1 1 10 Full 0 0 1 100 Half 1 1 1 10 Half 1 1 1

SW No. SW6 SW7 SW8

NOTE: 1 for DIP switch OFF, 0 for DIP switch ON.

INT-CLK

OFF SW6 BERT

SW7

LAN
REMOTE-LB

ON 1 2 3 4 5 6 7 8 LINE-CLK LINE-LB CRC

Figure 2- 6 DIP Switch on Rear Panel (For Framed Bridge)

2-9

SW8

OFF

OFF

OFF

Chapter 2 Installation

2.5 DIP Switch Operation for Bridge (Unframe)


Table 2- 10 E1 WANDIP Switch (SW3) Indication on Rear Panel (For Unframed Bridge) Function Line Loopback Direction
" (OFF) SW3 # (ON)

SW No.

Description Disable Line loopback Enable Line loopback

Default
" (OFF)

Table 2- 11 E1 WANDIP Switch (SW6 to SW8) Indication on Rear Panel (For Unframed Bridge) Auto-negotiation 1 1 1 100 Full 0 1 1 10 Full 0 0 1 100 Half 1 1 1 10 Half 1 1 1

SW No. SW6 SW7 SW8

NOTE: 1 for DIP switch OFF, 0 for DIP switch ON.

SW6

SW7

LAN ON 1 2 3 4 5 6 7 8 LINE-LB

Figure 2- 7 DIP Switch on Rear Panel (For Framed Bridge)

2-10

SW8

OFF

Chapter 2 Installation

Table 2- 12 DIP Switch Indication on Bottom Side NOTE: This DIP switch is for V.35, X.21, and framed Bridge interfaces only.

Functtion
E1 TS0

Direction
" (ON) # (OFF) " (ON) # (OFF)

Description
E1 is framed. E1 is unframed. Time slot is maped to DTE. Time slot is idle.

Default
" (ON) " (ON)

Frame status Time Slot status

E1 TS1 to 31

E1 TS

0
ON

7
ON

15
ON

23
ON

31

1 2 3 4 5 6 7

1 2 3 4 5 6 7

1 2 3 4 5 6 7

1 2 3 4 5 6 7

Figure 2- 8 DIP Switch on Bottom Side (For V.35, X.21, framed Bridge)

Example 1: E1 is framed. DTE rate = 3 x 64K = 192 Kbps on TS1, TS2, and TS3.

E1 TS

0
ON

7
ON

15
ON

23
ON

31

1 2 3 4 5 6 7

1 2 3 4 5 6 7

1 2 3 4 5 6 7

1 2 3 4 5 6 7

Example 2: E1 is unframed. DTE rate = 2048 Kbps. Note TS1 to TS31 are dont care.

E1 TS

0
ON

7
ON

15
ON

23
ON

31

1 2 3 4 5 6 7 8

1 2 3 4 5 6 7 8

1 2 3 4 5 6 7 8

1 2 3 4 5 6 7 8

2-11

Chapter 2 Installation

2.6 LED Operation


The front panel has 10 LEDs for operation and error indications. The following table lists each LED and its color and indications. Table 2- 13 Front Panel LED Table LED All LEDs POWER For DTE V.35
SYNC/TEST

Color Flashing $ Off Off Green Off Green Flashing Green Off Red Off Red Off Amber Off Red Off Flashing Green Flickering Green Flickering Green Off Red

Indication Self testing $ Initialization done Power off Power on Loss of frame sync or loss of signal Normal (Line in SYNC) Testing Normal or in unframe mode Loss of Frame Sync (LOFS) or Loss of Signal ( LOS) Normal or in unframe Loss of frame sync or loss of signal Normal or in unframe mode Receive Remote Alarm Indication from E1 line in frame mode Normal Line control slip Normal DTE in test Transmit data present Receive data present Normal Loss of clock from DTE or Clock source error

L I N E

LOF BPV RAI CS

D T E / V . 3 5

TEST TD RD CLK-LOSS

2-12

Chapter 2 Installation

LED For DTE X.21


SYNC/TEST

Color Off Green Flashing Green Off Red Off Red Flashing Red+ Test Green Off Amber Off Red Off

Indication Loss of frame sync or loss of signal Normal (Line in SYNC) Testing Normal or in unframe mode Loss of Frame Sync (LOFS) or Loss of Signal ( LOS) Normal or in unframe Loss of frame sync or loss of signal Test-pattern Bit error Normal or in unframe mode Receive Remote Alarm Indication from E1 line in frame mode Normal Line control slip Normal Status:

LOF L I N E

BPV

RAI CS

D T E / X . 2 1

NC and COM is short. NO and COM is open. ALARM/TEST NC and COM is open. Flashing Green Alarm Status: NO and COM is short. ! This LED, ALARM/TEST, will be lighted when these condition occurs: LOF, BPV, RAI, CS, CLK-LOSS, or power loss. NOTE: ! Press ACO button of front panel to clear alarm. TD Flashing Green Transmit data present RD Flashing Green Receive data present CLK-LOSS Off Red Normal Loss of clock from DTE or Clock source error

2-13

Chapter 2 Installation

LED For Bridge Frame


SYNC/TEST

Color Off Green Flashing Green Off Red Off Red Off Amber Off Red Green Flashing Green

Indication Loss of frame sync or loss of signal Normal (Line in SYNC) Testing Normal or in unframe mode Loss of Frame Sync (LOFS) or Loss of Signal ( LOS) Normal or in unframe Loss of frame sync or loss of signal Normal or in unframe mode Receive Remote Alarm Indication from E1 line in frame mode Normal Line control slip Link Active

E 1

LOF

W BPV A N RAI CS E T H E R N E T L A N E 1 W A N E T H E R N E T L A N
LINK

Link/Act

10/100

Off Green OFF Green

10Mbps 100Mbps Half duplex Full duplex

FDX

For Bridge Unframe

Green

Link

LINK/ACT

Green Flashing Green

Link Active

10/100

Off Green

10Mbps 100Mbps

FDX

OFF Green

Half duplex Full duplex

2-14

Chapter 3 Operation

3. OPERATION
This chapter describes the Loop-E 1510 CSU/DSU configuration options and operational functions.

3.1 DTE Configuration

3.1.1 CRC (Cycle Redundancy Check)


Loop-E can be used in two frame or multiframe mode. For two frame mode, set CRC (Cycle Redundancy Check) to OFF. For multiframe mode, set CRC to ON. A proprietary facility data link is implemented in both modes to facilitate remote system control and performance and statistics monitoring.

3.1.2 TTM (Terminal Timing Mode)


In the normal condition, Loop-E uses Transmit Clock to sample DTE Transmit Data, which is transmitted from DTE facility. In terminal timing mode, DTE facility uses Transmit Clock to drive Transmit Data and loop this clock to Loop-E via External Clock. In this mode, Loop-E will use External Clock to sample Transmit Data instead of using Transmit Clock. This method is to avoid phase delay due to cable length. In other words, if the DTE cable is too long, the transmit data may not in-phase with the Transmit Clock. With this feature, the External Clock and Transmit Data will be in-phase.

3.1.3 Clock Invert


The clock polarity of the DTE port is either normal or inverted. It is used to drive transmit data and to sample receive data.

3-1

Chapter 4 Maintenance

4. MAINTENANCE
4.1 Self-Test
At system power up, a complete self-test routine is run to check all I/O ports, read/write memory, and data paths to validate system integrity. During the system self test, all LEDs are flashing until the initializatiohn is done. When self-test is done, all LEDs are off.

4.2 Diagnostics 4.2.1 Line Loopback


Line loopback is illustrated in Figure 4-1. The incoming E1 line signal is loopback to the outgoing E1 signal before the E1 transceiver framer. This loopback is used to isolate the local equipment from a troubled E1 transmission line. Line loopback test can be activated from the front panel and terminal.

4.2.2 DTE to DTE Loopback


DTE to DTE port loopback is illustrated in the following figure. TO-DTE is when DTE incoming signal is loopback to the DTE outgoing signal. This loopback is used to validate the unit integrity of DTE facility.

E 1

Line Driver
2

Multiplexer

F r a m e r

Line Receiver

Line Loopback

DTE to DTE Loopback

Figure 4- 1 Loopback Block Diagram

4.3 Verifying Loop-E Operations


The purpose of this section is not to help the user determine where a possible fault in the network may lie. For this, the user needs to know the exact geometry of the network. Then standard network trouble shooting procedures should be followed, which involve sectionalizing the network and performing loopback tests on pieces of the network. The purpose here is to help the user determine whether the Loop-E equipment is at fault after tests have pointed a suspicious finger at this equipment. The procedures outlined here depends on test equipment and other equipment the user may have on hand. The organization of these procedures start from the simple to the complex. The procedure ends when a definitive conclusion is made that the Loop-E equipment is at fault. To verify that the Loop-E equipment is not at fault, specialized equipment such as a BERT (bit error rate test) set is needed.

4.3.1 Quick Test


See if the LEDs show any abnormal displays. If yes, use the LED indications to guide the user to test other parts of the network, such as the E1 line, or DTE equipment. Especially during initial installation, excessive errors may be due to (a) incorrect configuration of either LoopE or of the equipment at the other end of the line, or (b) due to faulty line installation, which results in

4-1

Chapter 4 Maintenance excessive noise, cross talk, or impedance mismatch. Especially in electrically noisy environments, such as central offices, use of shielded cables are mandatory.

4.3.2 Substitution
If a spare Loop-E is available, then replace the working one with the spare. The user must carefully configure the spare exactly as the working one. If the substitution clears the problem, then the original working one is suspect. Note that this is not definitive as other reasons may cause the same symptom. A good practice is to reconfigure the original one and swap once more. If both units behave the same, then the problem is probably elsewhere.

4.3.3 Using Loopback Plugs


Without a spare, loopback plugs are handy for diagnosis. Note that internal loopback facilities of the Loop-E does not include the interface circuitry. Thus a set of plugs, one for each of the interfaces, line and DTE, are needed for complete tests. These plugs are wired such that signals from the Loop-E are loopback by hard wire back to the receive pin of the same plug. Replace the line connector with a loopback plug. Observe if the line is in sync. If not then Loop-E has failed. Then perform a PRBS test towards the line. If this fails, then Loop-E has failed. For the DTE ports, a loopback plug must be used in concert with a far end Loop-E if such a terminal is available, then a PRBS test will determine if that DTE port is at fault. Note that if a far end terminal is available, the first test should be a local line loopback to see if the line is good. If the local DTE has diagnostic capabilities, then a loopback plug towards the DTE would help determine if the line to the DTE is good. This can further help isolate the problem. If tests with loopback plugs all pass, then the problem is probably elsewhere.

4.3.4 Using Bert Test Set


If a BERT (bit error rate test) set is a available, such as the Fireberd 6000, then a comprehensive suite of test are available to examine the health of the Loop-E. With a BERT, each of the ports of the Loop-E can be tested individually. The user must configure the BERT in the exact way the Loop-E is configured. This is easily done by comparing each of the options one by one. After checking that the configuration matches, if any one of the ports fails, then Loop-E has failed.

4-2