Académique Documents
Professionnel Documents
Culture Documents
CONTRACT PROPOSAL
TO Address Subject
: MR.RAKESH LADHANI / K.C.PANDEY : AMRIT BOTTLERS PVT.LTD. : PREE FRABRICATED STEEL BUILDING BOTTLERS PVT.LTD.
Dated -24/11/12
Dear sir , We acknowledge with thanks the receipt of your enquiry for supply of pre- engineered Steel Building Systems for your above mentioned project.
Based on the details furnished by you ,We are pleased to submit our proposal for your kind Consideration .Our scope of work includes Deign, Engineering, Fabrication and Supply & erection of Maternal in accordance with enclosed standards and specification unless otherwise stated. We trust you will find our proposal in line with your requirements. Should you require any further Clanifications /information. Please feel free to call us. Thanking you &assuring you our best attention at all times, we remain.
A) BUILDING A: Quanitity Building usage a) BASIC BUILDING DESCRITION UNIT (A) Frame type Width (M) Length (M) Clear Height (M) Roof stope Area Roof sheeting Wall Sheeting Flashings & gutter Wall sheeting starts Canopy Sky light RIGID FRAME 60 fit % 166 fit % 6.0m clear 1:10/two side slope 9960 SQET 0.50MM THCK COLOR COATED GALVALUME 0.50MM THCK COLOR COATED GALVALUME 0.50MM THCK COLOR COATED GALVALUME Wall sheeting starts at 3.0M brickwork NA. 2-4% 2MM THICK POLYCORBONATE SHEET 01 Storage block
B)DESIGN LOADS ITEM 1 2 3 4 5 DESCRIPTION Roof live load on purlins Roof live load on Frames Wind load (KMPH or KN/M2) SIESMIC ZONE DED LOAD 0.57 KN/M2 (working men) 0.57 KN/M2 (working men) 47M/S IV 0.10KN/M2
D. PHYSICAL SPECIFICATION OF STRUCTURAL MEMBERS: All other miscellaneous primary & secondary members shall have a minimum yield strength of (345 Mpa) E. ROOF SHEETING : Roof sheeting shall be of 0.5 mm thick profiled color galvalume of 345 mm to 550mpa max Strength and 150gsmcoating. F. FASTENERS : Structurel fastener will be chrome plated high tensile steel with hex head ,self tapping sheet metal Screws with metal and neoprene washers (HT) All screws shall have have hexagonal heads. Secondary fastner will be mild steel . G. SEALERSilicon ,sealant will be used to seal all the sheets leak etc. H. FLASHING AND TRIM: Flashing & / or trim shall be furnished at the rake. Corners eaves framed openings & wherever necessary to provide Whether tightness and finished appearance .Material shall be 26G thick Conforming to the physical specifications Having minimum yield strength of 345 Mpa
J .EAVE GUTTERS: Eave gulter will be of 0.5 mm thk color coated galvalume sheet.
Any product of service that is not clearly specified in this proposal 3.DELIVERY PERIOD VSR PVT .LTD Will dispatch the building in 4 weeks from the latest date of receipt of the following Erection of building will take further 2-3 weeks. Signed supply contract/purchase order. Advance payment & approval drawings.
4. SUPPLY PRICES
A. PRICE FOR THE BULING UNIT-(A)(IN PUPEES) TOTAL SUPPLY PRICE OF STEEL STRUCTURE & SHEETING -9960 SQFT @220= rs.21,91200.00 TOTAL ERECTION PRICE OF STEEL STRUCTURE @ SHEETING-02.50 LACKS THE PRICE IS INCLUDING OF FREIGHT,TRANSIT INSURANCE
B. TAXES & DUTIES # 5.5% VAT WILL BE CHARGED EXTRA # 10.3% SERVICE TAX WILL BE CHARGED EXTRA ON ERECTION AMOUNT.
C. TERMS OF PAYMENT:SUPPLY40% ADVANCE OF SUPPLY VALUE. 40% AGAINST PI/INSEPECTION OF STUCTURAL MATERIAL BEFORE DESPATCH. 20% AGAINST PI/INSEPECTION OF STUCTURAL MATERIAL BEFORE DESPATCH. ERECTION30% ADVANCE 40% ON COMPLETION OF STRUCTURE. 20% ON COMPLETION OF SHEETING. 10% ON COMPLETION OF FINISHING.
6.TERMS &CONDITIONS OF SALE 1. CANCELLATION: Agreement and orders CANNOT be cancelled or modified by BUYER under any circumstance Without BUYER frist reaching an agreement in writing with SELLER covering all damages. If Cancellation or modification is agreed to by SELLER. BUYER agrees to promptly pay all Reasonable engineering and other expenses incurred by SELLER in connection with this Agreement and in any case not less than 5% of the agreement price in case of cancelled. 2. EXCLUSIONS: SELLER supply does not include any material or labor in connection with foundations, concrete. Setting of anchor bolts, grouting under columns or in recess around bottem of wallsheets. Electrical installations, plumbing. Finished painting , heating, masonry. Interior finishing, partitions. Glass and glazings or any item not shown in RTNB offer. 3. WARRANTY: VSR PVT. LTD products are warranted against failure due to defective material or workmanship for a period Of 20 years after erection.