OPTINEX 1662SMC

1. RELACION ENTRE TARJETAS 2. VISTA FRONTAL DE TARJETAS 3. SUBSISTEMA DE CONEXIONES 4. SUBSISTEMA DE PROTECCION 5. PARMETROS DE INTERFACES OPTICAS 1 5 30 32 70

2.3

1 Relationship between Port Card and Access Card


Port Card acronym Port Card Slot Access Card acronym Access Card Slot

Table 19. Relationship between P63E1, P63E1N-M4 port card and A21E1 access card

P63E1 P63E1N

7 8 9 10 11 12 13 14

A63E1 A63E1 A63E1 A63E1 A63E1 A63E1 A63E1 A63E1

2(CH.1-63) 3(CH.1-63) 4(CH.1-63) 5(CH.1-63) 16(CH.1-63) 17(CH.1-63) 18(CH.1-63) 19(CH.1-63)

Table 20. Relationship between P63E1/P63E1N port card and A21E1 access card Port Card acronym Port Card Slot 7 8 9 10 P63E1 P63E1N P21E1 11 12 13 14 Access Card acronym A21E1 A21E1 A21E1 A21E1 A21E1 A21E1 A21E1 A21E1 Access Card Slot 2(Total 21CH,range from CH.1-63) 3(Total 21CH,range from CH.1-63) 4(Total 21CH,range from CH.1-63) 5(Total 21CH,range from CH.1-63) 16(Total 21CH,range from CH.1-63) 17(Total 21CH,range from CH.1-63) 18(Total 21CH,range from CH.1-63) 19(Total 21CH,range from CH.1-63)

There are two N+1 (N <= 3) EPS revertive protection scheme can be created (for more details see point [3] of para. 3.13.1). In case of EPS configuration the following configuration rules must be respected: Insert the protecting port card in a slot at the left or right of the protected port cards group. Insert the special protection access card (LPROT) associated to the protecting port card following the rule reported in Table 1. ( for example if the "protecting port card" has been inserted in slot 7, the "protection access card LPROT" must be inserted in slot 2). Table 21. Relationship between P3E3T3 port card and A3E3 access card Port Card acronym Port Card Slot Access Card acronym Access Card Slot

P3E3T3

7 8 9 10 11 12 13 14

A3E3 A3E3 A3E3 A3E3 A3E3 A3E3 A3E3 A3E3

2(CH.1-3) 3(CH.1-3) 4(CH.1-3) 5(CH.1-3) 16(CH.1-3) 17(CH.1-3) 18(CH.1-3) 19(CH.1-3)

One or more 1+N (N 7) EPS revertive protection scheme can be created (for more detail see point [3] of para. 3.13.1 ). In case of EPS configuration the following configuration rules must be respected:

Insert the protecting port card in a slot at the most left of the protected port cards group. Insert the special protection access card (HPROT) associated to the protecting port card following the rule reported in Table 21. . ( for example if the protecting port card has been inserted in slot 7, the protection access card HPROT must be inserted in slot 2).

Table 22. Relationship between P3E3T3 port card and A3T3 access card Port Card acronym P3E3T3 P3E3T3 P3E3T3 P3E3T3 P3E3T3 P3E3T3 P3E3T3 P3E3T3 Port Card Slot Access Card acronym Access Card Slot

7 8 9 10 11 12 13 14

A3T3 A3T3 A3T3 A3T3 A3T3 A3T3 A3T3 A3T3

2(CH.1-3) 3(CH.1-3) 4(CH.1-3) 5(CH.1-3) 16(CH.1-3) 17(CH.1-3) 18(CH.1-3) 19(CH.1-3)

One or more 1+N (N 7) EPS revertive protection scheme can be created (for more detail see point [3] of para. 3.13.1 ). In case of EPS configuration the following configuration rules must be respected: Insert the protecting port card in a slot at the most left of the protected port cards group. Insert the special protection access card (HPROT) associated to the protecting port card following the rule reported in Table 22. . ( for example if the protecting port card has been inserted in slot 7, the protection access card HPROT must be inserted in slot 2).

Table 23. Relationship between P4S1N, P4E4N, P4OC3 port card and A2S1 access card Port Card acronym P4E4N, P4S1N, P4OC3 (CH. 1-2) P4E4N, P4S1N, P4OC3 (CH. 1-2) P4E4N, P4S1N, P4OC3 (CH. 1-2) P4E4N, P4S1N, P4OC3 (CH. 1-2) P4E4N, P4S1N, P4OC3 (CH. 1-2) P4E4N, P4S1N, P4OC3 (CH. 1-2) P4E4N, P4S1N, P4OC3 (CH. 1-2) P4E4N, P4S1N, P4OC3 (CH. 1-2) Port Card Slot 7 8 9 10 11 12 13 14 Access Card acronym A2S1 A2S1 A2S1 A2S1 A2S1 A2S1 A2S1 A2S1 Access Card Slot 2 (CH. 3-4) 3 (CH. 3-4) 4 (CH. 3-4) 5 (CH. 3-4) 16 (CH. 3-4) 17 (CH. 3-4) 18 (CH. 3-4) 19 (CH. 3-4)

Table 24. Relationship between P4ES1N port card and A4ES1 access card. Port Card acronym P4ES1N P4ES1N P4ES1N P4ES1N P4ES1N P4ES1N P4ES1N P4ES1N Port Card Slot 7 8 9 10 11 12 13 14 Access Card acronym A4ES1 A4ES1 A4ES1 A4ES1 A4ES1 A4ES1 A4ES1 A4ES1 Access Card Slot 2 (CH. 1 to 4) 3 (CH. 1 to 4) 4 (CH. 1 to 4) 5 (CH. 1 to 4) 16 (CH. 1 to 4) 17 (CH. 1 to 4) 18 (CH. 1 to 4) 19 (CH. 1 to 4)

One or more 1+N (N 7) EPS revertive protection scheme can be created (for more detail see point [3] of para. 3.13.1 ). In case of EPS configuration the following configuration rules must be respected: Insert the protecting port card in a slot at the most left of the protected port cards group. Insert the special protection access card (HPROT) associated to the protecting port card following the rule reported in Table 24. ( for example if the protecting port card has been inserted in slot 7, the protection access card HPROT must be inserted in slot 2).

The STM-4 and STM-16 high speed port card does not need Access Card because the physical termination of the channel is on the port itself. Table 25. Relationship between ETH-MB port card and ETH-ATX access card. Port Card acronym ETH-MB (CH. 1 to 11) ETH-MB (CH. 1 to 11) ETH-MB (CH. 1 to 11) ETH-MB (CH. 1 to 11) ETH-MB (CH. 1 to 11) ETH-MB (CH. 1 to 11) ETH-MB (CH. 1 to 11) ETH-MB (CH. 1 to 11) Port Card Slot 7 8 9 10 11 12 13 14 Access Card acronym ETH-ATX ETH-ATX ETH-ATX ETH-ATX ETH-ATX ETH-ATX ETH-ATX ETH-ATX Access Card Slot 2 (CH. 12 to 25) 3 (CH. 12 to 25) 4 (CH. 12 to 25) 5 (CH. 12 to 25) 16 (CH. 12 to 25) 17 (CH. 12 to 25) 18 (CH. 12 to 25) 19 (CH. 12 to 25)

Table 26. Relationship between ETH-MB port card and GETH-AG (1.25 Gb/s) access card. Port Card acronym ETH-MB (10/100 Mb CH.1 to 11) ETH-MB (10/100 Mb CH.1 to 11) ETH-MB (10/100 Mb CH.1 to 11) ETH-MB (10/100 Mb CH.1 to 11) ETH-MB (10/100 Mb CH.1 to 11) ETH-MB (10/100 Mb CH.1 to 11) ETH-MB (10/100 Mb CH.1 to 11) ETH-MB (10/100 Mb CH.1 to 11) Port Card Slot 7 8 9 10 11 12 13 14 Access Card acronym GETH-AG GETH-AG GETH-AG GETH-AG GETH-AG GETH-AG GETH-AG GETH-AG Access Card Slot (N.B.) 2 (Gigabit CH. 1 and 2) 3 (Gigabit CH. 1 and 2) 4 (Gigabit CH. 1 and 2) 5 (Gigabit CH. 1 and 2) 16 (Gigabit CH. 1 and 2) 17 (Gigabit CH. 1 and 2) 18 (Gigabit CH. 1 and 2) 19 (Gigabit CH. 1 and 2)

N.B.

The following channels are made available (max quantity) when GETH-AG is used in conjunction with ETH-MB: up to two Gigabit Ethernet interface on the access card GETH-AG;in this configuration only the two upper interfaces present on the access card can be used for Gbit Ethernet application. up to eleven 10/100 Mbit Ethernet interfaces on the ETH-MB.

Table 27. Relationship between ISA ES-16 port card and and ETH-ATX access card. Port Card acronym ISA ES-16 ISA ES-16 ISA ES-16 ISA ES-16 ISA ES-16 ISA ES-16 ISA ES-16 ISA ES-16 Port Card Slot 7 8 9 10 11 12 13 14 Access Card acronym ETH-ATX ETH-ATX ETH-ATX ETH-ATX ETH-ATX ETH-ATX ETH-ATX ETH-ATX Access Card Slot 2 3 4 5 16 17 18 19

Table 28. Relationship between ISA ES-16 port card and and GETH-AG access card. Port Card acronym ISA ES-16 ISA ES-16 ISA ES-16 ISA ES-16 ISA ES-16 ISA ES-16 ISA ES-16 ISA ES-16 Port Card Slot 7 8 9 10 11 12 13 14 Access Card acronym GETH-AG GETH-AG GETH-AG GETH-AG GETH-AG GETH-AG GETH-AG GETH-AG Access Card Slot 2 3 4 5 16 17 18 19

Table 29. Relationship between ISA-PR port card and 16FEA-PR or 2GBA-PR access cards. Port Card acronym ISA-PR ISA-PR Port Card Slot 8 12 Access Card acronym 16FEA-PR or 2,4 2GBA-PR 16FEA-PR or 16,18 2GBA-PR Access Card Slot

5
ACRONYM S-4.1N L-4.1N L-4.2N SLOTS 7,8,9,10,11,12,13,14 7,8,9,10,11,12,13,14 7,8,9,10,11,12,13,14

Figure 35.

STM-4 optical port card front view

6
ACRONYM P4S4N SLOTS 7, 9, 11, 13

LEGENDA (1) Channel #1 (N.B.) (2) Channel #2 (N.B.) (3) Multicolor LED: Red led - local unit alarm Green led - in service unit

NOTE: the unit can be equipped with optical modules.

Figure 36.

4 x STM4 port card front view

ACRONYM S-16.1N L-16.1N L-16.2N

SLOTS 7,9,11,13 7,9,11,13 7,9,11,13

Figure 37.

STM16 optical front view

8
ACRONYM I-16.1ND SLOTS 7, 9, 11, 13

Figure 38.

I16 PORT SFF (intraoffice)

ACRONYM CO-16

SLOTS 7, 9, 11, 13

Figure 39.

STM16 SFP port optical front view

10

ACRONYM ETH-MB

SLOTS 7,8,9,10,11,12,13,14

LEGENDA (1)-(11) Ethernet channels (12) not used (13) Bicolor LED: Red led - local unit alarm Green led - in service unit

Figure 41.

ISA - Ethernet port front view

10

11
ACRONYM GETHMB SLOTS 7,8,9,10,11,12,13,14

LEGENDA (1)-(4) Gigabit Ethernet channels (5) Bicolor LED: Red led - local unit alarm Green led - in service unit (6) Factory used only

Figure 42.

ISA Gigabit ETHERNET board

11

12

ACRONYM ES4-8FE

SLOTS 7,8,9,10,11,12,13,14

Figure 43.

ISA ES48FE port front view

12

13

ACRONYM ISA-ES1 8FE

SLOTS 7,8,9,10, 11,12,13,14

LEGENDA (1) to (8) Ethernet channels (9) Channel status indicators: Yellow: active channel Yellow blinking: channel with traffic (10) not used (11) Microprocessor restart Key (12) Bicolor LED: Red led - local unit alarm Green led - in service unit

Figure 44.

ISA - ES1 8FE port front view

13

14

ACRONYM ISA-ES1 8FX

SLOTS 7,8,9,10,11,12,13,14

Figure 45.

ISA - ES1 8FX port front view

14

15

ACRONYM ISA-ES16

SLOTS 7,9,11,13

Figure 46.

ISA ES16 front view

15

16
ACRONYM CONGI SLOTS 1, 20

LEGENDA (1) Power (2) Housekeeping and remote alarm (3) Rack lamps (not used on CONGI in slot 20) (4) QMD (Q2) (not used on CONGI in slot 20) (5) I/O BNC for Q3 10 base 2(not used on CONGI in slot 20) (6) RJ45 for Q3 10 baseT (not used on CONGI in slot 20) (7) Bicolor LED: Red led - local unit alarm Green led - in service unit

Figure 52.

Control and General interface

16

17
ACRONYM SERGI SLOTS 20

LEGENDA (1) Power Auxiliary channel (2) Auxiliary channel: 2 channel G.703 2 channel RS232 2 channel V.11 (3) Aux and Sync. 2Mbit/s J1- 2MHz Input (T3) or 2Mbit/s Input (T6) J2- 2Mbit/s Input channel J3- 2MHz Output (T4) or 2Mbit/s Output (T5) J4- 2Mbit/s Output channel (4) Four wire telephone extertion point (RJ11) (5) Z1-Z4 EOW zone selection LEDs (6) L1-L2 LEDs status for selective and multiple call (7) Telephone jack (8) Line seizure key (9) EOW zone selection key (10) Reset command key (11) Bicolor LED: Red led - local unit alarm Green led - in service unit

Figure 53.

SERGI card

17

18

ACRONYM ESERGI

SLOTS 20

LEGENDA (1) Power connector (2) Auxiliary channel: 2 channel G.703 2 channel RS232 2 channel V.11 (3) 2MHz or 2Mbit/s input B/A (4) 2Mbit/s for AUX input /output (5) 2MHz or 2Mbit/s output (6) Four wire telephone extertion point (RJ11) (7) Z1-Z4 EOW zone selection LEDs (8) L1-L2 LEDs status for selective and multiple call (9) Telephone jack (10) Three buttons for: Line seizure key EOW zone selection key Reset command key (11) Bicolor LED: Red led - local unit alarm Green led - in service unit

Figure 54.

ESERGI card interface

18

19
ACRONYM SYNTH16 SLOTS 5,16

LEGENDA (1) (2) (3) (4) (5) (6) (7) (8) (9) (10) Reset command key Channel #1 Lamp test pushbutton Personal computer connector (F interface) Red led Urgent alarm (Critical or Major ) Red led Not Urgent alarm ( Minor ) Yellow led Alarm storing (Attended) Yellow led Abnormal condition Yellow led Indicative Alarm (Warning) Green led When on it means active unit,and when off it means standby unit. (11) Bicolor LED: Red led - local unit alarm Green led - in service unit (12) Alarm storing pushbutton (Attended)

Figure 55.

SYNTH16 card - front view

19

20
ACRONYM A63E1A (75Ohm) A63E1B (120Ohm) SLOTS 2,3,4,5,16,17,18,19 2,3,4,5,16,17,18,19

LEGENDA (1) (2) (3) (4) (5) (6) (7) (8) (9) channel #1-7 channel #8-14 channel #15-21 channel #22-28 channel #29-35 channel #36-42 channel #43-49 channel #50-56 channel #57-63

Figure 57.

63 X 2 Mbit/s access card

20

21
ACRONYM LPROT HPROT SLOTS 2 to 5, 16 to 19 2, 4, 16, 18

LEGENDA (1) Bicolor LED: Red led - local unit alarm Green led - in service unit

Figure 60.

Low/High Speed protection - front view

21

22
ACRONYM A2S1 SLOTS 2,3,4,5,16,17,18,19

LEGENDA (1)Channel #3 (N.B.) (2)Channel #4 (N.B.) (3)Bicolor LED: Red led - local unit alarm Green led - in service unit

N.B.- The unit can be equipped with electrical or optical modules . Figure 61.
2 x 140/STM-1 adapter (access card) - front view

22

23
ACRONYM A3E3 A3T3 SLOTS 2,3,4,5,16,17,18,19 2,3,4,5,16,17,18,19

LEGENDA (1) Channel #1 (2) Channel #2 (3) Channel #3 (4) Bicolor LED: Red led - local unit alarm Green led - in service unit

Figure 62.

3 X 34/45 Mbit/s 75 ohm access card

23

24

ACRONYM A4ES1

SLOTS 2,3,4,5,16,17,18,19

LEGENDA (1) Channel #1 (2) Channel #2 (3) Channel #3 (4) Channel #4 (5) Bicolor LED: Red led - local unit alarm Green led - in service unit

Figure 67.

4 X STM-1 access card

24

25
MODULE ACRONYM S-1.1 L-1.1 L-1.2 MM1 EQUIPED ON PORTS P4S1N P4ES1 ATM4X4 A2S1 SYNTH4

Figure 68.

STM-1 or STM-4 optical module

25

26

MODULE ACRONYM ICMI

EQUIPED PORTS P4S1N P4ES1 ATM4X4 A2S1 SYNTH4

ON

Figure 69.

STM-1 or 140 Mbit/s electrical module

26

27

Figure 70.

Relationship between SFP modules and housing boards

27

28

ACRONYM BST10 BST15 BST17

SLOTS 2,4,16,18 2,4,16,18 2,4,16,18

Figure 75.

Optical Booster card front view

28

29

Figure 76.

SYNTH16 Optical module

29

30 3.2 Connections sub-system

This sub-system allows connections between any SDH, SONET, PDH or ISA (Integrated Service Adapter) ports (see Figure 93. ). The connections can be realized at VC-12, VC-3, and VC-4 level using a not blocking matrix present on the COMPACT unit. Several types of connections may be established, such as: Unidirectional Point to Point Unidirectional Point to Multipoint Bidirectional Point to Point The maximum matrix cross connection capability can be 96 x 96 STM-1 equivalent port at VC-4 level or 64x64 STM-1 equivalent port at VC-12 / VC-3 level + 32x32 equivalent port at VC-4 level. The following table illustrates the connections for each unit: Table 33. High Order/Low Order connections for 1662SMC STM-1, STM-4, STM-16 ports PORTS STM-1, STM-4, STM-16 TU-3 TU-12 AU-3 VC-4 VC-3 VC-12 Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Structure AU-4 AU-4 Yes TU-3 TU-12 OC3 ports AU-3 140 Mbit/s ports VC-4 Yes 34 Mbit/s 45 Mbit/s ports VC-3 2 Mbit/s ports VC-12 -

OC3 140 Mbit/s 34Mbit/s 45Mbit/s 2Mbit/s

The above connections allows the 1662SMC to realize Multi Line Terminal configuration, Add/Drop configuration and Mini Cross-Connect configurations in linear links, rings, and mashed network as describe in Chapter 1. AU4-4C and AU4-16C concatenated signals can also be cross connected between any STM-4 and STM-16 ports. Examples of connection type are shown in Figure 93. : connections between 2 Mbit/s ports and STM-1 ports connections between 34 Mbit/s ports and STM-1 ports connections between 45 Mbit/s ports and STM-1 ports connections between 140 Mbit/s ports and STM-1 ports VCn connections between STM-1 ports and STM-4 ports VCn connections between STM-1 ports and STM-16 ports VCn connections between STM-4 ports and STM-16 ports VCn connections between ports of the same type etc.

The maximum quantity of interconnections depends on the matrix capacity .

30

31
STM-4 STM-16 STM-16

MATRIX spare
(1) (2) (3) (4) (5) (1)

4xANY

(6) (7)

(1)

4xOC3

MATRIX main access card

(1)

(1)

(1)

(1)

"Spare" 4X 140 Mbit/s 4X STM-1

63x2 Mbit/s "Main"

34/45 Mbit/s

ISA units

access card NOTES:


(1)

access card

access card

access card

access card

2 Mbit/s to 2 Mbit/s connections, 34Mbit/s to 34 Mbit/s connections, 45 Mbit/s to 45 Mbit/s connections, 140 Mbit/s to 140 Mbit/s, 155 Mbit/s to 155 Mbit/s STM-4 to STM-4, STM-16 to STM-16, 4xANY to 4xANY, OC3 to OC3. STM-1 to STM-4/STM-16 connections; ISA to STM-1/STM-4/STM-16 140 Mbit/s to STM-1/STM-4/STM-16 connections 34 or 45 Mbit/s to STM-1/STM-4/STM-16 connections 2 Mbit/s to STM-1/STM-4/STM-16 connections 4xANY to STM-4/STM-16 connections OC3 to STM-1/STM-4/STM-16 connections ISA = ATM Matrix, PR_EA Matrix, ES and Ethernet boards

(2) (3) (4) (5) (6) (7)

Figure 93.

High Order/Low Order connections for 1662SMC

31

32 3.13

Protection sub-system
Equipment protection (EPS) The EPS protection is supported on the 1662SMC equipment for the following cards : Equipment Boards
Matrix Low Speed ports : - 63x2Mbit/s High Speed electrical ports : - 4xSTM-1 elect. - 3x34/45Mbit/s ATM matrix 4x4 ATM matrix 8X8 ISA ES16 MPLS boards -PR_EA Matrix 4xEthernet -PR_EA Matrix 1xGB-Ethernet 1+1 1+1 2 2 Not revertive Not revertive 1+1 1+1 1+1 4 2 4 Not revertive Not revertive Not revertive N+1 (N max=7) 4 Revertive

The types of protections are:

Protection Scheme
1+1 N+1 (N max = 3)

Number of protection schemes


1 2

Mode
Not revertive Revertive

N.B.

Note that for the LS and HS ports, the protection scheme 1+1 is a particular case of an 1+N EPS protection scheme (is then revertive).

Network protections: MSP (Multiple Section linear trail Protection) 1+1 linear single-ended 1+1 linear dual-ended 1 : N linear dual-ended

SNCP/I and SNCP/N It is used on ring, linear and mesh network topology. Switching occurs on the path, selecting (Rx side) the signal transmitted to both Tx A and Tx B ( A and B are two different directions) sides. Drop & Continue It is an architecture to connect sub-networks, in order to improve traffic availability. Collapsed dual node ring interconnection It is an architecture to connect sub-networks, in order to improve traffic availability with hardware resource reduction (two nodes collapse in one node).

32

Collapsed single node ring interconnection It is an architecture to connect sub-networks, in order to improve traffic availability with hardware resource reduction (four nodes collapse in one node). 2F MS-SPRING, 2 fibres Multiple Section Shared Protection

33

The switching information is also indicated on the Craft Terminal screen. 3.13.1 EPS Protections [1] COMPACT ADM card protection The positions of main and spare MATRICES are fixed : [2] Slot 6 : COMPACT ADM main Slot 15 : COMPACT ADM spare

Low Speed (LS) port protection (See Figure 172. )

As Low Speed ports (LS) are intended the 2 Mbit/s ports. Up to 8 LS ports can be housed in the subrack. For the relation between LS ports and access cards refer to para 2.3. Two protection groups N+1 revertive can be created , depending on the equipment configuration. The spare card position can be assigned in a flexible way . The only constraint are the following : the access card corresponding to the protecting card must be an LPROT card. the LPROT card can be plugged at the right or left side of the access card group. the main/spare ports have to be adjacent.

The positions of main and spare P63E1 are optional. The following is an example (see Figure 173. ): slot 8 : P63E1 main slot 7 : P63E1 spare

The P63E1 port can manage up to 63 x 2 Mbit/s port. Sixty-three bidirectional links are used for each connection between P63E1 port and A63E1 or A21E1 access card. The main P63E1 ports are connected in a fixed way to A63E1 or A21E1 access cards using point-to-point connections. The spare P63E1 port is connected to LSPROT card also using point-to-point connections. (refer to para 2.3) Under alarm condition, the signal transmitted and received from the main port is switched towards the LSPROT card, and then connects to the spare port. In the following a generic description of the access card is given: Input side Under normal operating condition, the signal received from the line is sent to the 63 x 2 Mbit/s pertaining port card. Under alarm condition, the signal received from the line is switched towards the LSPROT card. The switching command SEL is received from the RIBUS I/F block. A protection block is present to protect the incoming signal against spikes (G.703). Output side Under normal operating condition, the signal received from the main port is sent to the line. Under alarm condition, the signal received from the spare port is switched towards the LSPROT card and

33

then sent to the line. The SEL command, received from the RIBUS I/F block, select the signal to sent to the line The LSPROT card is used to realize EPS protection for Low Speed ports. It realizes the connection between the spare port card and LS protection bus if protection request. The switches to select between main links and protection links are located on the access cards and managed by the RIBUS block. The switch is activated in case of failure. Figure 172. shows the connection between P63E1 main port, P63E1 spare port ,access card A63E1 or A21E1 and LSPROT card.

34

ACCESS CARD
2Mbit/ s from/ to DDF

LSPROT. CARD

63x2 Mbit/ s MAIN PORT CARD


63 protection links

63x2 Mbit/ s SPARE PORT CARD

63 protection bus

Slot 2

switch

Slot 3

Slot 7

Slot 8

RIBUS 63 main links

DATA

DATA

COMPACTADM (SYNTH)

Figure 172.

Low Speed Link Connections

34

35

Figure 173.
[3]

Example of Low Speed port EPS protection scheme

High Speed (HS) port protection (See Figure 174. and Figure 175.)

As High Speed ports (HS) are intended the 34 Mbit/s , 45 Mbit/s and 155 Mbit/s speed ports. Up to 8 HS ports can be housed in the port area. For the electrical HS ports the corresponding access cards have to be put in the access area with fixed relations (refer to para 2.3 ). More than one protection group N+1 revertive can be created , depending on the equipment configuration. For each group N + 1 protected group the revertive mode is supported. The spare card position can be assigned in a flexible way . The only constraint are the following : the access card corresponding to the protecting card must be an HPROT card the HPROT card has to be plugged at the left side of the access card group the main/spare ports have to be adjacent. the protecting card has to be plugged at the left side of the protected group of ports the protecting/protected group of ports have to be of the same type. The only exception is for the 3x34/3x45 port card : it can be a protecting card for both 3x34 or 3x45 port card i.e. a mixed group of ports can be protected by the same spare card.

Figure 174. gives some examples of EPS protection scheme.

35

36

EXAMPLE 1: 4 x STM-1 Electrical port EPS protected P4ES1 N+1 (N=1)

EXAMPLE 2: 3 x34Mbit/s EPS protected P3E3/T3 N+1 (N=1)

36

37

EXAMPLE 2: 3 x45Mbit/s EPS protected P3E3/T3 N+1 (N=1) Figure 174. Example of EPS protection schemes
Manual Switch and force switch commands can be given via software by the user to activate the spare cards. The protections status is reported to the EC. Figure 175. shows the High Speed connections for the 2+1 protection. Each access card is connected also with the previous one and with the next one; in this way N+1 protection is provided using HPROT card in last position at the left side of the access cards pertaining to the protected port group. Each electrical High Speed port can manage up to 4 HS streams. Input side ( from the access module point of view) The CMI encoded signal coming from the line and connected to the access card is NRZ decoded. The clock CK is extracted from the data. By means of the back panel connections , NRZ data and CK are forwarded to the pertaining main port and to the spare port. Moreover NRZ data and Clock are sent to the next access card if present to perform N +1 protection. The spare port should not be devoted to a specific main port therefore a distributed switch matrix (on every access card ) is used to allows the signal to gain the spare port. The command criteria for the distributed switch matrix comes from the matrix unit via serial interface. Output side ( from the access module point of view ) The signal , coming from Main and Spare ports via back panel connections , is coded into CMI format. The spare port is not devoted to a specific main port, therefore the signal transmitted from the spare is distributed to all access cards involved in the protection scheme. The connections are functionally point-to-multipoint but physically every access card realizes a point -to-point connection towards the previous and the next access card using a buffer to decouple and regenerate the signal. Hardware failures types

37

The hardware failures causing automatic EPS protection switch can be grouped as : failures causing the internal equipment link loss as powering KO, Clock loss, card missing (referred as LOS/LOF) failures causing traffic loss (the internal link is preserved) as for instance unlocked oscillator, optical module defective, electrical interface defective and so on. failures not causing traffic loss nor internal link loss but causing loss of management as ISBP failure or SPI failure.

38

Moreover some failures can cause equipment malfunctioning ( as remote inventory fault, laser degrade, loss of DC/DC synchronism ). These hardware faults are signalled to the management system and do not provokes an automatic switch.

38

39

Figure 175.

High Speed connections

39

40
ANEXO 1: PARAMETROS OPTICOS

40

41

41

Table 72. Parameters specified for Optical Booster CHARACTERISTICS BOOSTER Maximum Output power Minimum Output power Maximum Input power Minimum Input power Polarization Depending Gain Reverse ASE power level Input Optical Return Loss (ORL) Pump Leakage to Input Pump Leakage to Output Maximum ORL tolerable at Input Power Wavelength Bandwidth

42
UNIT + 10 dBm dBm dBm dBm dBm dB dBm dBm dBm dBm dB nm +12 +10 +4 -6 VALUES + 15 dBm + 17 + 15 +4 -6 < 0.5 -20 27 -36 Pout-30 > 27 1530~1565 + 17 dBm + 19 + 17 +4 -6

42