Vous êtes sur la page 1sur 5

MiniLink TN Configuration

1. Basic NE Configuration

Go to NE Configure Basic NE

NTP Server Setting (To synch. the time with server) Detail: Set Continent= Etc Set City= UTC Set NTP Server= 10.3.13.1

Automatic Backup Setting Detail: Set Automatic Backup= to remote ftp server from drop down list

PM Start Time Detail: Set PM Start Time= 00:00 Save the changes by clicking Save button in craft

2. DCN Configuration

Go to NE Configure DCN

FTP Settings (To enable NE automatic backup and export of error logs) Detail: Set Remote FTP Server ID = 10.3.13.1 Set Username= swdownload Set Password= #som# Save the changes by clicking Save button in craft

3. Radio Link Configuration

Go to MMU Configure Configure Radio Link

Radio ID Change Detail: Open the Configure Radio Link window and launch the far end as well Uncheck Radio ID Check Option at both ends Save the changes by clicking Save button in craft

Set Terminal ID= As per plan

Set Far End ID = As per plan Save the changes by clicking Save button in craft

Tx Power Setting Detail: Check the link transmit power, RSL and frequency from LB.

Check the Output Power Mode settings. It should be ATPC for all 11GHz link and RTPC for all other frequencies or stated otherwise in LB. LB must be consulted for mode conformation. Note down the link if configuration is not as above.

For ATPC links verify the following: Output Power should be set to max. allowable limit. Change the limit accordingly. Save the changes by clicking Save button in craft

Target Input Power should be set to -50 dBm. Note down the link if Target Input Power configuration is not as above. No changes should be done.

Change the Output Power according to LB if Output Power Mode=RTPC. In case of 1+1 link, changes must be done on all RAUs. Save the changes by clicking Save button in craft

Frequency Check

In case of frequency conflict, no activity needs to be performed. Please note down the link.

RF Input Alarm Threshold Detail: Open Advanced menu for both ends. For links with RTPC settings: Set RF Input alarm threshold= 8dBm less than design RSL.

For links with ATPC settings: Set RF Input alarm threshold= -55 dBm

Save the changes by clicking Save button in craft

4. Switch Configuration

Expand MMU RAU IF Go to SWITCH Configure Protection

For 1+1 links verify the switch configuration settings. Switch Mode must be set = Automatic at both ends. Change the settings to Automatic if not done already

Save the changes by clicking Save button in craft