Flare Gas

Web

Chem & Proc Tech

FREE MAGAZINES
Flare Drum Madcap Flare Ground Flare Flare Pants

Ads by Google

Hot Posts
Useful Documents Related t (PRV) - Part 1 Pressure Relief Valve (PRV) ha overpressure protection of pres equipment. Regardless of vess designed in accordance to any e.g. ASME, JIS, BS, GB, etc,...

Monday, March 23, 2009

Pipe Flow Calculator www.flowmaster.com Analyse gas and liquid flows rates in piping systems Flow Meters for Water www.awflowmeters.com/water Cooling water applications & flow monitoring. 2" line size, 150 GPM LFG Engineering www.haase-energietechnik.de Landfill gas: extraction, disposal, power generation - CHP units Coalescing & Conventional www.Temprite.com Oil Separators for All Refrigerants including CO2 & Ammonia

FOLLOW ME

Enter your email address: Display problem ? Click HERE Recommended : - Tips on Succession in FREE Subscription - Subscribe FREE - Chemical Processing Earlier post "Quick Estimate Flare Tip Pressure Drop" has presented some clues in obtaining flare tip pressure drop for sonic and subsonic tip. Particularly for subsonic flare tip, a simple pressure drop versus flow curve was presented. This graph may be used for quick estimation during conceptual stage so that it minimize unnecessary time lost. However, the graph has limited to 0.5 - 40 kPa with correspondent minimum and maximum flow. Some conceptual studies may have flaring capacity resultant pressure drop more than 40 kPa, the graph may not be useful. In this post, a simple formula will be presented in order to estimate pressure drop for any flow rate for dedicated flare tip.

SUPPORT This Site

dP = 10 ^ (a x Log Q + b)
where dP = tip pressure drop, kPa Q = Flow at standard condition, dm3/s (note 1) a & b = coefficient correspondent to tip size as list in following table Tip Nom. Dia. (mm) 250 400 450 500 600 a b

1.772663 -5.287376 1.92372 -6.671917 1.948852 -7.034009 1.945342 -7.329128 1.954552 -7.791866

1 of 3

27/04/2011 13:39

http://webwormcpt.blogspot.com/2009/03/estimate-subsonic-flare-tip-pressure.html

750 900 1050 1200

1.968898 -8.24243 1.89152 -8.14936 1.722666 -7.781574 1.532001 -7.181798

Note 1 : The standard condition may be different from project to project (read more in "Avoid Confusion In "Standard" Flow Definition". Present standard definition is at 101.325 kPa abs and 15 degC. Example Estimate pressure drop of a subsonic flare tip with flow of 30,000 Sm3/h. Q = 30,000 x 1000 / 3600 =8333.3 dm3/s @ Std (i) A DN250 tip, dP = 10 ^ ( 1.772663 x Log Q - 5.287376) dP = 10 ^ ( 1.772663 x Log 8333.3 - 5.287376) dP = 46 kPa (outside curve)

(ii) A DN400 tip, dP = 10 ^ ( 1.92372 x Log Q - 6.671917) dP = 10 ^ ( 1.92372 x Log 8333.3 - 6.671917) dP = 7.4 kPa (iii) A DN450 tip, dP = 10 ^ ( 1.948852 x Log Q - 7.034009) dP = 10 ^ ( 1.948852 x Log 8333.3 - 7.034009) dP = 4.0 kPa (iv) A DN500 tip, dP = 10 ^ ( 1.945342 x Log Q - 7.329128) dP = 10 ^ ( 1.945342 x Log 8333.3 - 7.329128) dP = 2.0 kPa You may compare results with chart in "Quick Estimate Flare Tip Pressure Drop".

Quick Estimate Flare Tip Pressure Drop Several Criteria and Constraints for Flare Network - Process Several Criteria and Constraints for Flare Network - Piping Provide More than One Flare KOD in SERIES Flare Tip Quick Selection Chart Flare Smokeless Ringlemann Chart Labels: Flare, FLARENET

Ads by Google
Pipe Flow Rate Acute Gout Flare Iridium Flare Enclosed Flare Emergency Flare
Recommended Jobs Chemical Engineer Cikarang - PT Priuk Perkasa Abadi Process Improvement Specialist Jakarta - EONCHEMICALS PUTRA, PT Process Engineer Jakarta - PT Bidar Timur Sales Engineer for Process Jakarta - PT. Yabestindo Mitra Utama Process Engineer (Code : PEG) South Jakarta - CITRA NUSANTARA GEMILANG

Process engineer jobs

PROCESS ENGINEER
WESTINDO ESA PERKASA, PT - Cibinong
located at Cibinong, Bogor is looking for : PROCESS ENGINEER Requirements : S1 degree with background... Jobs Keywords: PROCESS ENGINEER Personal Notes... JobsDB Indonesia more jobs

Jobs by Indeed
www.indeed.com

2 of 3

27/04/2011 13:39

http://webwormcpt.blogspot.com/2009/03/estimate-subsonic-flare-tip-pressure.html

posted by Webworm, 11:13 AM

Post a Comment
Let us know your opinion !!! You can use some HTML tags, such as <b>, <i>, <a>

Subscribe to Post Comments [Atom]

Create a Link

<< Home

2008-2010 Chemical & Process Technology | Design by Webworm

3 of 3

27/04/2011 13:39

Vous aimerez peut-être aussi