SPECIFICATIONS

No Lead Floor Water Cooler Water Cooled Models EFW16, EFWC16 (Corrosion-Resistant)

GENERAL Self-contained, electric refrigerated, floor model water cooler. Capacity of 50F drinking water, based upon 80F inlet water. Non-pressurized tank system is standard. Non-pressurized water tank is located after bubbler valve, so that tank is subject to line pressure only when valve button is pressed. NO LEAD DESIGN THIS WATER COOLER COMPLIES WITH THE LEAD-FREE DEFINITION IN THE SAFE DRINKING WATER ACT OF 1986 AND LEAD CONTAMINATION CONTROL ACT OF 1988. Elkay Water Coolers are manufactured with a waterway system utilizing copper components and completely lead-free materials. These waterways have no lead because all lead materials, such as leaded brass, have been removed. All joints are brazed using silver solder only. No lead solder is permitted. A strainer with an easily cleanable screen is provided to allow trapping and convenient removal of waterborne particulate of 140 microns and larger prior to their entry into the water cooler. CAPACITIES CHART
Model Number Base Rate *GPH of 50F Drinking Water Room Temperature F 70F 80F 90F Rated Watts Full Load Amps Glass Filler Option Ship. Wt. Lbs.

Model EFWC16

EFW16 EFWC16

9.5 9.5

16.0 16.0

16.0 16.0

16.0 16.0

340 340

4.5 4.5

Yes No

85 85

*Based on 80F inlet water temperature. Glass filler available at extra cost. Require factory preparation to receive glass filler. Rated watts shown are based on operational (run) time, in accordance with A.R.I. Standard 1010 conditions. Specific applications will determine the actual watts consumed per hour. Watts consumed will be based on number of people served per hour (usage), ambient temperatures, and inlet water temperature. Foot pedal available. Factory installed only. (Not available on corrosionresistant model.)

COOLING SYSTEM Motor Compressor: Hermetically sealed, reciprocating type, 115V, 60 Hz single phase. Sealed-in lifetime oil supply. Equipped with electric cord and three prong molded rubber plug. Condenser: Water cooled and has automatic condenser valve. Cooling Unit: Combination tube-tank type. Tube portion is continuous coil of copper tubing. Tank is stainless steel. Fully insulated with EPS foam which meets Underwriters Laboratories Inc. requirements for self extinguishing material. Refrigerant Control: Refrigerant HFC-134a is controlled by accurately calibrated capillary tube for positively trouble-free performance. Temperature Control: Enclosed adjustable thermostat is factory preset. Requires no adjustment other than for altitude requirements. CONSTRUCTION Fountain Top: One piece stainless steel top, polished to a uniform Elkay bright luster finish. Exclusive Cascade basin, tested most splash-resistant, features multi-level deck design with a built-in vandal-resistant strainer. Exclusive Flexi-Guard Safety Bubbler: Innovative design utilizes a pliable elastomer to prevent accidental mouth injuries. Flexes on impact, then returns to original position. Strong. Abrasion-resistant. Anti-sweat.

Corrosion-Resistant Model EFWC16 is equipped with chrome-plated brass bubbler with push button control. Bubbler has inline flow regulator for use between 20 and 105 psi. Both bubblers meet UL requirements and all sanitary codes. Removable Panel: Removable front panel offers easy accessibility to interior. Color Selection: EFW16 models available in Light Gray Granite, Almond, Sandalwood and Stainless Steel panels. Corrosion-resistant EFWC16 model available in Type 316 Stainless Steel only. Cabinet: Cabinet design allows for flush to wall mounting or free standing. OTHER Corrosion-resistant Model EFWC16 features type 316 stainless steel cabinet, base and stainless steel fasteners. A special protective coating is also applied to the compressor, condenser, cooling tank, waterways and refrigerant lines. Protected by Elkays 5 Year Limited Warranty on the refrigeration system of the unit. Elkay Pressure-Type Water Coolers are designed to operate on 20 psi to 105 psi supply line pressure. If inlet pressure is above 105 psi, a pressure regulator must be installed in the supply line. Any damage caused by reason of connecting this product to supply line pressures lower than 20 psi or higher than 105 psi is not covered by the warranty. STANDARDS Elkay Electric Air Cooled Water Coolers are listed by Underwriters Laboratories Inc. and comply with both Canadian and U.S. requirements. These units comply with A.R.I. Standard 1010.
This cooler is certified by WQA to lead-free compliance including NSF/ANSI 61-ANNEX G, AB 1953.

In keeping with our policy of continuing product improvement, Elkay reserves the right to change product specifications without notice. Please visit elkayusa.com for most current version of Elkay product specification sheets.

This specification describes an Elkay product with design, quality and functional benefits to the user. When making a comparison of other producers offerings, be certain these features are not overlooked.

Elkay
elkayusa.com

2222 Camden Court Oak Brook, IL 60523

Printed in U.S.A. 2011 Elkay (Rev. 4/11)

9-4I

No Lead Floor Water Cooler Water Cooled Models EFW16, EFWC16 (Corrosion-Resistant)
)mm23( "4/1-1 ECEIPLIAT .D.O TON PART( )DEHSINRUF "8/5-4 )mm711( GNINIATNIAM YB NOITALITNEV REPORP ERUSNI :ETON C TENIBAC MORF ECNARAELC MUMINIM )mm201( "4 L .RELOOC FO EDIS HCAE NO LLAW OT SREVUOL DETACOL EB NAC NI-HGUOR GNIBMULP .AERA SIHT NIHTIW EREHWYNA "2/1-41 )mm863( GNOL )mm2.1( TOOF 4 DROC REWOP LANOITPO TELTUO LACIRTCELE )SREHTO YB( NIARD KNAT TELTUO LACIRTCELE )SREHTO YB( NOITACOL )mm23( "4/1-1 ECEIPLIAT .D.O "2/1-2 )mm46( "2/1-41 )mm863( "5 "4/1-4 )mm721( )mm801( "81 )mm754( ENIL ROOLF TELTUO RETAW )mm23( .S.P.I "4/1-1 "8/3-14 RETAW DLOC SPI "8/3 )mm1501( TUO BUTS( YLPPUS )mm52( "1 LLAW MORF FFOTUHS TELNI RETAW SREHTO YB EVLAV )TELTUO EBUT .D.O "8/3( "71 )mm234( "04 )mm6101(

ROUGH-IN DIMENSIONS

1/4" O.D. TUBE WATER INLET TO COOLER

3/8" O.D. TUBE CONNECT BUILDING WATER COLD WATER SUPPLY INLET

NOTE: WATERFLOW DIRECTION

SERVICE STOP (NOT FURNISHED)

OPERATION OF QUICK CONNECT FITTINGS


SIMPLY PUSH IN TUBE IS SECURED PUSH IN COLLET TUBE TO ATTACH IN POSITION TO RELEASE TUBE

IMPORTANT! INSTALLER PLEASE NOTE: This water cooler has been designed and built to provide water to the user which has not been altered by materials in the cooler waterways. The grounding of electrical equipment such as telephone, computers, etc., to water lines is a common procedure. This grounding may be in the building but may also occur away from the building. This grounding can cause electrical feedback into a water cooler creating an electrolysis which creates a metallic taste or causes an increase in the metal content of the water. This condition is avoidable by installing the cooler using the proper materials as shown below. NOTICE This water cooler must be connected to the water supply using a dielectric coupling. The cooler is furnished with a non-metallic strainer which meets this requirement. The drain trap which is provided by the installer should also be plastic to completely isolate the cooler from the building plumbing system.

C PUSHING TUBE IN BEFORE PULLING IT OUT HELPS TO RELEASE TUBE

14-1/2" (368mm)

18" (457mm)

14-1/2" (368mm)

17" (432mm) 40" (1016mm) 41-3/8" (1051mm) 3/8" IPS COLD WATER SUPPLY (STUB OUT FROM WALL 1" (25mm) WATER INLET SHUTOFF VALVE BY OTHERS (3/8" O.D. TUBE OUTLET) WATER OUTLET 1-1/4" I.P.S. (32mm) FLOOR LINE C L

TANK DRAIN

ELECTRICAL OUTLET LOCATION (BY OTHERS) 1-1/4" (32mm) O.D. TAILPIECE 2-1/2" (64mm) 5" (127mm) 4 FOOT (1.2mm) LONG POWER CORD OPTIONAL ELECTRICAL OUTLET (BY OTHERS)

1-1/4" (32mm) O.D. TAILPIECE (TRAP NOT FURNISHED) 4-5/8" (117mm)

4-1/4" (108mm)

NOTE: INSURE PROPER VENTILATION BY MAINTAINING 4" (102mm) MINIMUM CLEARANCE FROM CABINET LOUVERS TO WALL ON EACH SIDE OF COOLER. PLUMBING ROUGH-IN CAN BE LOCATED ANYWHERE WITHIN THIS AREA.

Elkay
9-4I
(Rev. 4/11)

2222 Camden Court Oak Brook, IL 60523 elkayusa.com

Printed in U.S.A. 2011 Elkay