Vous êtes sur la page 1sur 44

Sheet1 Table C.

1 Time Attribute Enumerations Index 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 RESERVED RESERVED RESERVED RESERVED RESERVED RESERVED RESERVED Billing-Shifted Block RESERVED Daily-Shifted Instantaneous Monthly-Shifted RESERVED Present Previous Previous-Season Q1-Shifted Q2-Shifted Q3-Shifted Q4-Shifted Seasonal Sub-block Weekly-shifted Expiration Has Last Next Requires Start Table C.2 -- Data Qualifier Enumerations Index 0 1 2 3 4 5 6 7 8 9 10 11 Enumeration Absolute Average Compensated Excess HighThreshold Incremental LowThreshold Maximum Minimum Missing Nominal Page 1 Enumeration

Sheet1 12 13 Normal Relative Table C.3 Accumulation Behaviour Enumerations Index 0 Enumeration

1 BulkQuantity

2 ContinuousCumulative 3 Cumulative

4 DeltaData

6 Indicating 7 IntervalData 8 RecordedData 9 Summation 10 TimeDelay Table C.4 Direction Of Flow Enumerations Index 0 1 2 3 4 5 6 7 8 9 Enumeration Forward Lagging Leading Net Q1+Q2 Q1+Q2+Q3+Q4 Q1+Q3 Q1+Q4 Q1-Q4 Page 2

Sheet1 10 11 12 13 14 15 16 17 18 19 20 Q2+Q3 Q2+Q4 Q2-Q3 Q3+Q4 Q3-Q2 Quadrant1 Quadrant2 Quadrant3 Quadrant4 Reverse Total Table C.5 Unit of Measure Enumerations Attribute 5.1 Subclass 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 Attribute 5.2 Index 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 Page 3

Sheet1 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20

Page 4

Sheet1 1 1 1 1 1 1 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 21 22 23 24 25 26 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 30 31 32 33 Table C.6 Measurement Categories Attribute 6.1 Category 0 1 2 3 4 Table C.7 MeasurementCategory Enumerations Page 5

Sheet1 Attribute 6 Categorized Index 0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 1.1 1.2 1.3 1.4 1.5 1.6 1.7 2 2.1 2.2 2.3 2.4 2.5 2.6 2.7 2.8 2.9 2.1 2.15 2.3 2.45 2.6 21.55 2.31 3.1 3.2 3.3 3.4 3.5 3.6 3.7 4.39 4.71 4.75 4.76 4.84 4.98 Enumeration

Harmonic1 Harmonic2 Harmonic3 Harmonic4 Harmonic5 Harmonic6 Harmonic7 Interharmonic1 Interharmonic2 Interharmonic3 Interharmonic4 Interharmonic5 Interharmonic6 Interharmonic7 n0 n1 n2 n3 n4 n5 n6 n7 n8 n9 n10 n15 n30 n45 n60 n155 n305 TouRateA TouRateB TouRateC TouRateD TouRateE TouRateF TouRateG JPY ZAR SEK CHF USD EUR Page 6

Sheet1 Table C.8 Phase Enumerations 0 128 136 132 225 193 129 64 72 66 97 65 32 40 40 41 33 16 224 Phase-A Phase-AA Phase-AB Phase-ABC-N Phase-AB-N Phase-AN Phase-B Phase-BA Phase-BC Phase-BC-N Phase-BN Phase-C Phase-CA Phase-CA Phase-CA-N Phase-CN Phase-N Phases-ABC Table C.9 Metric Multiplier Enumerations 0 1 2 3 6 9 255 254 253 250 247 Da h or % K M G d c m n Table C.10 Unit of Measure Enumerations Value 0 2 3 4 5 6 7 8 9 10 11 Quantity N/A Length Mass Rotational speed Current Temperature Amount of substance Luminous intensity Plane angle Plane angle Solid angle

Page 7

Sheet1 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 41 42 43 44 45 46 47 48 49 50 51 52 53 54 61 63 64 65 66 67 68 69 70 71 72 73 74 75 76 Absorbed dose Radioactivity Relative temperature Dose equivalent Electric capacitance Electric charge Time Electric inductance Electric potential Electric resistance Energy joule Force newton Frequency hertz Illuminance lux Luminous flux Magnetic flux Magnetic flux density Real power Pressure Area Volume Velocity Acceleration Volumetric flow rate Fuel efficiency Moment of mass Density Viscosity Thermal conductivity Heat capacity Concentration Electric conductance Angular velocity Apparent power Reactive power Phase angle Power factor Volt seconds Volts squared Amp seconds Amps squared Amps squared time Apparent energy Real energy Reactive energy Magnetic flux Rate of change of frequency Number of characters Page 8

Sheet1 77 78 79 80 100 101 102 103 104 105 106 107 108 109 110 111 113 114 115 116 117 118 Data rate Turbine inertia Sound pressure level Monetary unit Quantity power Quantity energy resistivity A/m volt-squared hour ampere-squared hour Ampere-hours Wh/m3 Timestamp Boolean BooleanArray Count Signal Strength ApplicationValue Kh-Wh Kh-VArh Kh-Vah EndDeviceEvent

Page 9

Sheet1 Table C.1 Time Attribute Enumerations Comments Not Applicable, or the bulk quantity of a commodity (e.g. the dial reading on an electromechanical watt-hour meter) Reserved for 10-minute Reserved for 15-minute Reserved for 1-minute Reserved for 24-hour Reserved for 30-minute Reserved for 5-minute Reserved for 60-minute Billing period shifted (whatever the billing period is) A block of data Reserved for 2-minute Daily Self-Read Typically measured over tens of milliseconds Monthly Self-Read Reserved for 3-minute Within the present monthly cycle Within the previous monthly cycle and data set Within the previous season and data set First Quarter Second Quarter Third Quarter Fourth Quarter e.g. Summer, Spring, Fall, and Winter based cycle A portion of a block of data Weekly Self Read The time at which an action is scheduled to expire. Exists or is Of all the previous readings, this one is the most recent chronologically. Of any future (pending) events, this one is next. Must or Mandates The time at which an action is scheduled to start. Table C.2 -- Data Qualifier Enumerations Comments Not Applicable

Page 10

Sheet1

Table C.3 Accumulation Behaviour Enumerations Comments Not Applicable, or implied by the unit of measure. A value from a register which represents the bulk quantity of a commodity. This quantity is computed as the integral of the commodity usage rate. This value is used as the basis for the dial reading at the meter, and as a result, may roll over upon reaching a maximum dial value. Note: This enumeration is usually implied by the context. Users may elect to omit phrases implied by their context from a textual description (e.g. the alias name), but choose to retain them in the numeric description (e.g. the name). The sum of the previous billing period values and the present period value. The sum of the previous billing period values. The "consumption" or "usage" of a commodity between two distinct points in time. Or alternatively, the quantity consumed over a specific period of time (with "zero" at the start of the measurement). The period over which the begin and endpoints occur may be non-recurring or irregular (such as a billing period which changes size with the number of days in a month). Further context is provided by the TimeAttribute, Flow direction, and the time-stamp(s). (See also "Interval data" for a related concept). As if a needle swung out to a value to indicate the current value. The "delta" difference between two values at regularly spaced intervals in time. The use of "IntervalData" implies that the datum is part of a consecutive series of data sampled at uniform intervals of time. A series of data samples accompanied by timestamp(s) A form of accumulation which may be selective with respect to time. Note: This enumeration is usually implied by the unit of measure. A form of computation which introduces a time delay characteristic to the data value Table C.4 Direction Of Flow Enumerations Comments N/A "Delivered," or "Import" See 61968-2 Typically used to describe that a power factor or reactive energy component is lagging the reference value. Typically used to describe that a power factor or reactive energy component is leading the reference value. |Forward| - |Reverse|, See 61968-2 Reactive positive quadrants Sum of all quadrants Quadrants 1 and 4 Q1 minus Q4 Page 11

Sheet1 Quadrants 2 and 3 Q2 minus Q3 Reactive negative quadrants Q3 minus Q2

"Received," or "Export" See 61968-2 |Forward| + |Reverse|, See 61968-2 Table C.5 Unit of Measure Enumerations Enumeration Air ApparentPowerFactor Currency Current CurrentAngle CurrentImbalance Date Demand Distance DistortionVoltAmperes Energization Energy EnergizationLoadSide Fan Frequency Funds IEEE1366ASAI IEEE1366ASIDI IEEE1366ASIFI IEEE1366CAIDI IEEE1366CAIFI IEEE1366CEMIn IEEE1366CEMSMIn IEEE1366CTAIDI IEEE1366MAIFI IEEE1366MAIFIe IEEE1366SAIDI IEEE1366SAIFI InsulativeGas InsulativeOil LineLosses Losses NegativeSequence Page 12

Sheet1 PhasorPowerFactor PhasorReactivePower PositiveSequence Power PowerFactor Price QuantityPower Sag Swell SwitchPosition TapPosition TariffRate Temperature TotalHarmonicDistortion TransformerLosses UNIPEDEVoltageDip10to15 UNIPEDEVoltageDip15to30 UNIPEDEVoltageDip30to60 UNIPEDEVoltageDip60to90 UNIPEDEVoltageDip90to100 Voltage VoltageAngle VoltageExcursion VoltageImbalance Volume ZeroFlowDuration ZeroSequence ApplicationContext ApTitle AssetNumber Bandwidth BatteryVoltage BroadcastAddress DeviceAddressType1 DeviceAddressType2 DeviceAddressType3 DeviceAddressType4 DeviceClass ElectronicSerialNumber EndDeviceID GroupAddressType1 GroupAddressType2 GroupAddressType3 GroupAddressType4 IpAddress MacAddress MfgAssignedConfigurationID MfgAssignedPhysicalSerialNumber

Page 13

Sheet1 MfgAssignedProductNumber MfgAssignedUniqueCommunicationAddress MultiCastAddress OneWayAddress SignalStrength TwoWayAddress Alarm BatteryCarryover DataOverflowAlarm DemandLimit DemandReset Diagnostic EmergencyLimit EncoderTamper IEEE1366MomentaryInterruption IEEE1366MomentaryInterruptionEvent IEEE1366SustainedInterruption InterruptionBehaviour InversionTamper LoadInterrupt LoadShed Maintenance PhysicalTamper PowerLossTamper PowerOutage PowerQuality PowerRestoration Programmed Pushbutton RelayActivation RelayCycle RemovalTamper ReprogrammingTamper ReverseRotationTamper SwitchArmed SwitchDisabled Tamper WatchdogTimeout Table C.6 Measurement Categories Error Harmonics Interharmonics Ordinal or cardinal numbering Time of Use (TOU) tier numbering Currency code (per ISO 4217) Table C.7 MeasurementCategory Enumerations Page 14

Sheet1 Comments Not Applicable fundamental second harmonic third harmonic fourth harmonic fifth harmonic sixth harmonic etc. (additional harmonics (up to 999) created as necessary in category=0) fundamental second interharmonic third interharmonic fourth interharmonic fifth interharmonic sixth interhamonic etc. (additional interharmonics (up to 999) created as necessary in category=1) Zeroth unit (for systems that use zero based numbering schemes) First; or "1" where the measure needs an argument such as CEMI(n=1) Second; or "2" where the measure needs an argument such as CEMI(n=2) Third; or "3" where the measure needs an argument such as CEMI(n=3) Fourth; or "4" where the measure needs an argument such as CEMI(n=4) Fifth; or "5" where the measure needs an argument Sixth, or "6" Seventh, or "7" Eigth, or "8" Nineth, or "9" Tenth, or "10" 15 30 45 60 155 necessary in class=2) First Tier Second Tier Third Tier Fourth Tier Fifth Tier Sixth Tier etc. (additional tiers (up to 999) created as necessary in class=3) Japanese Yen, adapted from ISO 4217 currency codes South African Rand Swedish Krona Swiss Franc US Dollar Euro Page 15

Sheet1 Table C.8 Phase Enumerations Not Applicable to any phase Phase A Phase A current relative to Phase A voltage Phase A to B ABC to Neutral AB to Neutral Phase A to Neutral Phase B Phase B current relative to Phase A voltage Phase B to C BC to Neutral Phase B to Neutral Phase C Phase C current relative to Phase A voltage Phase C to A CA to Neutral Phase C to Neutral Neutral Involving all phases Table C.9 Metric Multiplier Enumerations Not Applicable or "x1" Deca = x10 = x101 hecto, x100 (or a dimensionless value expressed as a percentage) = x102 kilo, x1,000 = x103 Mega, x1,000,000 = x106 Giga = x1,000,000,000 = x109 Deci = x0.1 = x10-1 Centi = x0.01 = x10-2 milli, x0.001 = x10-3 micro, x0.000,001 = x10-6 nano, x0.000,000,001 = x10-9 Table C.10 Unit of Measure Enumerations Unit name none meter gram rotations per second ampere Kelvin mole candela degrees radian steradian

Page 16

Sheet1 Gray (J/kg) Becquerel (l/s) degrees Celsius Sievert (J/kg) Farad (C/V) Coulomb (AS) second Henry (Wb/A) Volt (W/A) Ohm (VA) (N m) (kg m/s) (1/s) (lm/m) lumen (cd sr) Weber (V s) Tesla (Wb/m2) Watts (IR) Pascal (N/m) square meter cubic meter meters per second (m/s) meters per second squared cubic meters per second meters / cubic meter kilogram meter (kg m) kilogram/cubic meter meter squared / second Watt/meter Kelvin Joule/Kelvin parts per million Siemens (A/V) radians per second Volt Ampere Volt Ampere reactive (VISin) degrees dimensionless Volt seconds (Ws/A) Volt squared (W2/A2) amp seconds amp squared amp square second Volt Ampere hours Watt hours Volt Ampere reactive hours Volts per Hertz hertz per second characters Page 17

Sheet1 characters per second kg square meter decibel Money (Note: Generic money unless supplemented with ISO 4217 currency codes via MeasurementCategory Enumerations). Q Qh (rho) magnetic field strength, Ampere per metre Volt-squared-hours Ampere-squared hour Ampere-hours energy per volume time and date per ISO 8601 "1" = "true", "live", "on", "high", "set"; "0" = "false", "dead", "off", "low", "cleared" An array of boolean values describing an An array of boolean values describing an array or gang of switches counter value receive signal strength indicator encoded value active energy metering constant reactive energy metering constant apparent energy metering constant value to be interpreted as a EndDeviceEventCode

Page 18

Sheet1

Page 19

Sheet1

Page 20

Sheet1

Comments Not Applicable

Page 21

Sheet1

or Voltage Dip

DR

Page 22

Sheet1

Page 23

Sheet1

Page 24

Sheet1

ons 0 1 1 1 1 1 1 0 0 0 0 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 0 0 0

1 1

Symbol m g rev/s A K mol cd deg rad sr

Page 25

Sheet1 Gy Bq C Sv F C seconds H V J N Hz lx Lm Wb T W Pa m m m/s m/s m/s m/m M kg/m m/s W/m K J/K ppm Siemens rad/s VA VAr -Deg Cos Vs V As A At VAh Wh VArh V/Hz Hz/s char Page 26

Sheet1 char/s kgm dB Q Qh m A/m Vh Ah Ah Wh/m timeStamp status statuses Count dBm Code Wh/rev VArh/rev VAh/rev MeCode

Page 27

TimeAtt Enumeration BLANK 10MINUTE 15MINUTE 1MINUTE 24HOUR 30MINUTE 5MINUTE 60MINUTE BILLING-SHIFTED BLOCK 2MINUTE DAILY_SHIFTED INSTANTANEOUS MONTHLY_SHIFTED 3MINUTE PRESENT PREVIOUS PREVIOUS-SEASON Q1-SHIFTED Q2-SHIFTED Q3-SHIFTED Q4-SHIFTED SEASONAL SUB-BLOCK WEEKLY-SHIFTED EXPIRATION HAS LAST NEXT REQUIRES START Table C.1 Time Attribute Enumerations Index 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30

Page 28

TimeAtt

ute Enumerations Comments Not Applicable, or the bulk quantity of a commodity (e.g. the dial reading on an electromechanical watt-hour meter) Reserved for 10-minute Reserved for 15-minute Reserved for 1-minute Reserved for 24-hour Reserved for 30-minute Reserved for 5-minute Reserved for 60-minute Billing period shifted (whatever the billing period is) A block of data Reserved for 2-minute Daily Self-Read Typically measured over tens of milliseconds Monthly Self-Read Reserved for 3-minute Within the present monthly cycle Within the previous monthly cycle and data set Within the previous season and data set First Quarter Second Quarter Third Quarter Fourth Quarter e.g. Summer, Spring, Fall, and Winter based cycle A portion of a block of data Weekly Self Read The time at which an action is scheduled to expire. Exists or is Of all the previous readings, this one is the most recent chronologically. Of any future (pending) events, this one is next. Must or Mandates The time at which an action is scheduled to start.

Page 29

DataQualifier Table C.2 -- Data Qualifier Enumerations Enumeration Index Comments Not 0 Applicable Absolute 1 Average 2 Compensated 3 Excess 4 HighThreshold 5 Incremental 6 LowThreshold 7 Maximum 8 Minimum 9 Missing 10 Nominal 11 Normal 12 Relative 13

Page 30

AccumulationBehaviour Table C.3 Accumulation Behaviour Enumerations Enumeration Index 0

BulkQuantity

ContinuousCumulative Cumulative

2 3

DeltaData

Indicating IntervalData RecordedData Summation TimeDelay

6 7 8 9 10

Page 31

AccumulationBehaviour

.3 Accumulation Behaviour Enumerations Comments Not Applicable, or implied by the unit of measure. A value from a register which represents the bulk quantity of a commodity. This quantity is computed as the integral of the commodity usage rate. This value is used as the basis for the dial reading at the meter, and as a result, may roll over upon reaching a maximum dial value. Note: This enumeration is usually implied by the context. Users may elect to omit phrases implied by their context from a textual description (e.g. the alias name), but choose to retain them in the numeric description (e.g. the name). The sum of the previous billing period values and the present period value. The sum of the previous billing period values. The "consumption" or "usage" of a commodity between two distinct points in time. Or alternatively, the quantity consumed over a specific period of time (with "zero" at the start of the measurement). The period over which the begin and endpoints occur may be non-recurring or irregular (such as a billing period which changes size with the number of days in a month). Further context is provided by the TimeAttribute, Flow direction, and the time-stamp(s). (See also "Interval data" for a related concept). As if a needle swung out to a value to indicate the current value. The "delta" difference between two values at regularly spaced intervals in time. The use of "IntervalData" implies that the datum is part of a consecutive series of data sampled at uniform intervals of time. A series of data samples accompanied by timestamp(s) A form of accumulation which may be selective with respect to time. Note: This enumeration is usually implied by the unit of measure. A form of computation which introduces a time delay characteristic to the data value

Page 32

FlowDirection Enumeration Forward Lagging Leading Net Q1+Q2 Q1+Q2+Q3+Q4 Q1+Q3 Q1+Q4 Q1-Q4 Q2+Q3 Q2+Q4 Q2-Q3 Q3+Q4 Q3-Q2 Quadrant1 Quadrant2 Quadrant3 Quadrant4 Reverse Total Table C.4 Direction Of Flow Enumerations Index 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20

Page 33

FlowDirection Comments N/A "Delivered," or "Import" See 61968-2 Typically used to describe that a power factor or reactive energy component is lagging the reference value. Typically used to describe that a power factor or reactive energy component is leading the reference value. |Forward| - |Reverse|, See 61968-2 Reactive positive quadrants Sum of all quadrants Quadrants 1 and 4 Q1 minus Q4 Quadrants 2 and 3 Q2 minus Q3 Reactive negative quadrants Q3 minus Q2

umerations

"Received," or "Export" See 61968-2 |Forward| + |Reverse|, See 61968-2

Page 34

Phase Table C.8 Phase Enumerations 0 Phase-A Phase-AA Phase-AB Phase-ABCN Phase-AB-N Phase-AN Phase-B Phase-BA Phase-BC Phase-BC-N Phase-BN Phase-C Phase-CA Phase-CA Phase-CA-N Phase-CN Phase-N Phases-ABC 128 136 132 225 193 129 64 72 66 97 65 32 40 40 41 33 16 224 Not Applicable to any phase Phase A Phase A current relative to Phase A voltage Phase A to B ABC to Neutral AB to Neutral Phase A to Neutral Phase B Phase B current relative to Phase A voltage Phase B to C BC to Neutral Phase B to Neutral Phase C Phase C current relative to Phase A voltage Phase C to A CA to Neutral Phase C to Neutral Neutral Involving all phases 0 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 0 0 0

Page 35

Phase

erations 0 0 0 0

1 1 1 1 1

1 1 1 1

1 1 1

1 1

Page 36

MetricMultiplier 0 1 2 3 6 9 255 254 253 250 247 Table C.9 Metric Multiplier Enumerations Not Applicable or "x1" Da Deca = x10 = x101 hecto, x100 (or a dimensionless value expressed as a h or % percentage) = x102 K kilo, x1,000 = x103 M Mega, x1,000,000 = x106 G Giga = x1,000,000,000 = x109 d Deci = x0.1 = x10-1 c Centi = x0.01 = x10-2 m milli, x0.001 = x10-3 micro, x0.000,001 = x10-6 n nano, x0.000,000,001 = x10-9

Page 37

Unity Quantity NA LENGTH MASS ROTATIONAL_SPEED CURRENT TEMPERATURE AMOUNT_OF_SUBSTANCE LUMINOUS_INTENSITY PLANE_ANGLE_DEGREES PLANE_ANGLE_RADIANS SOLID_ANGLE ABSORBED_DOSE RADIOACTIVITY RELATIVE_TEMPERATURE DOSE_EQUIVALENT ELECTRIC_CAPACITANCE ELECTRIC_CHARGE TIME ELECTRIC_INDUCTANCE ELECTRIC_POTENTIAL ELECTRIC_RESISTANCE ENERGY_JOULE FORCE_NEWTON FREQUENCY_HERTZ ILLUMINANCE_LUX LUMINOUS_FLUX MAGNETIC_FLUX MAGNETIC_FLUX_DENSITY REAL_POWER PRESSURE AREA VOLUME VELOCITY ACCELERATION VOLUMETRIC_FLOW_RATE FUEL_EFFICIENCY MOMENT_OF_MASS DENSITY VISCOSITY THERMAL_CONDUCTIVITY HEAT_CAPACITY CONCENTRATION ELECTRIC_CONDUCTANCE ANGULAR_VELOCITY APPARENT_POWER REACTIVE_POWER Value (0), (2), (3), (4), (5), (6), (7), (8), (9), (10), (11), (21), (22), (23), (24), (25), (26), (27), (28), (29), (30), (31), (32), (33), (34), (35), (36), (37), (38), (39), (41), (42), (43), (44), (45), (46), (47), (48), (49), (50), (51), (52), (53), (54), (61), (63),

Table C.10 Unit of Measure En

Page 38

Unity PHASE_ANGLE POWER_FACTOR VOLT_SECONDS VOLTS_SQUARED AMP_SECONDS AMPS_SQUARED AMPS_SQUARED_TIME APPARENT_ENERGY REAL_ENERGY REACTIVE_ENERGY MAGNETIC_FLUX RATE_OF_CHANGE_OF_FREQUEN CY NUMBER_OF_CHARACTERS DATA_RATE TURBINE_INERTIA SOUND_PRESSURE_LEVEL MONETARY_UNIT QUANTITY_POWER QUANTITY_ENERGY RESISTIVITY A/M VOLT_SQUARED_HOUR AMPERE_SQUARED_HOUR AMPERE_HOURS WH_PER_M3 TIMESTAMP BOOLEAN BOOLEANARRAY COUNT SIGNAL_STRENGTH APPLICATIONVALUE KH_WH KH_VARH KH_VAH ENDDEVICEEVENT (64), (65), (66), (67), (68), (69), (70), (71), (72), (73), (74), (75), (76), (77), (78), (79), (80), (100), (101), (102), (103), (104), (105), (106), (107), (108), (109), (110), (111), (113), (114), (115), (116), (117), (118),

Page 39

Unity Table C.10 Unit of Measure Enumerations Unit name // none // meter // gram // rotations per second // ampere // Kelvin // mole // candela // degrees // radian // steradian // Gray (J/kg) // Becquerel (l/s) // degrees Celsius // Sievert (J/kg) // Farad (C/V) // Coulomb (AS) // second // Henry (Wb/A) // Volt (W/A) // Ohm (VA) // (N m) // (kg m/s) // (1/s) // (lm/m) // lumen (cd sr) // Weber (V s) // Tesla (Wb/m2) // Watts (IR) // Pascal (N/m) // square meter // cubic meter // meters per second (m/s) // meters per second squared // cubic meters per second // meters / cubic meter // kilogram meter (kg m) // kilogram/cubic meter // meter squared / second // Watt/meter Kelvin // Joule/Kelvin // parts per million // Siemens (A/V) // radians per second // Volt Ampere // Volt Ampere reactive (VISin)

Page 40

Unity // degrees // dimensionless // Volt seconds (Ws/A) // Volt squared (W2/A2) // amp seconds // amp squared // amp square second // Volt Ampere hours // Watt hours // Volt Ampere reactive hours // Volts per Hertz // hertz per second

// characters // characters per second // kg square meter // decibel // Money (Note: Generic money unless supplemented with ISO 4217 currency codes via MeasurementCategory Enumerations // Q // Qh // (rho) // magnetic field strength, Ampere per metre // Volt-squared-hours // Ampere-squared hour // Ampere-hours // energy per volume // time and date per ISO 8601 // "1" = "true", "live", "on", "high", "set"; "0" = "false", "dead", "off", "low", "cleared" // An array of boolean values describing an array or gang of switches // counter value // receive signal strength indicator // encoded value // active energy metering constant // reactive energy metering constant // apparent energy metering constant // value to be interpreted as a EndDeviceEventCode

Page 41

Unity Symbol m g rev/s A K mol cd deg rad sr Gy Bq C Sv F C seconds H V J N Hz lx Lm Wb T W Pa m m m/s m/s m/s m/m M kg/m m/s W/m K J/K ppm Siemens rad/s VA VAr

Page 42

Unity -Deg Cos Vs V As A At VAh Wh VArh V/Hz Hz/s char char/s kgm dB Q Qh m A/m Vh Ah Ah Wh/m timeStamp status statuses Count dBm Code Wh/rev VArh/rev VAh/rev MeCode

Page 43

Sheet11 Reading Types CELESC IA IB IC VA VB VC AVA AVB AVC AIA AIB AIC DHVA DHVB DHVC DHIA DHIB DHIC DHT FR SIGNAL TEMP OPER CH1 CH2 CH3 0.0.6.0.0.4.0.128.0.5 0.0.6.0.0.4.0.64.0.5 0.0.6.0.0.4.0.64.0.5 0.0.6.0.0.54.0.128.0.29 0.0.6.0.0.54.0.64.0.29 0.0.6.0.0.54.0.32.0.29 0.0.6.0.0.55.0.128.0.64 0.0.6.0.0.55.0.64.0.64 0.0.6.0.0.55.0.32.0.64 0.0.6.0.0.5.0.128.0.64 0.0.6.0.0.5.0.64.0.64 0.0.6.0.0.5.0.32.0.64 0.0.6.0.0.100.0.128.0.0 0.0.6.0.0.100.0.64.0.0 0.0.6.0.0.100.0.32.0.0 0.0.6.0.0.101.0.128.0.0 0.0.6.0.0.101.0.64.0.0 0.0.6.0.0.101.0.32.0.0 0.0.6.0.0.47.0.224.0.0 0.0.6.0.0.15.0.224.0.33 0.0.6.0.1.25.0.0.0.0 0.0.6.0.0.46.0.0.0.6 0.0.6.0.1.27.0.0.0.0 0.0.6.0.3.1.0.0.0.0 0.0.6.0.3.2.0.0.0.0 0.0.6.0.3.3.0.0.0.0

Page 44

Vous aimerez peut-être aussi