Académique Documents
Professionnel Documents
Culture Documents
FEATURES
SOLENOID VALVES
3/2
Series
U
3 2
307
Lever type Manual Reset function which means that the valve has to be energized as well as manually operated before it stays in the "latched" position The No Voltage Release (NVR) function will make sure that the valve trips when de-energized The solenoid valves are recommended for 3/2 way pilot applications with full flow and wide pressure ranges Stainless steel or brass bodied valves with stainless steel internal parts The use of first class materials and thorough valves testing ensure a high reliability and a long service life The solenoid valves satisfy all relevant EC Directives
GENERAL
() Ensure that the compatibility of the fluids in contact with the materials is verified Brass body Stainless steel body Body Brass AISI 316 SS Core tube Stainless steel Stainless steel Core and plugnut Stainless steel Stainless steel Springs Stainless steel Stainless steel Seals NBR NBR Disc and poppets NBR NBR Seat Brass Stainless steel
BP MP RP LP
0,4W - 1,7W Low power Not Available Reduced power Not Available Medium power 16,7W-22,6W Basic power
SPECIFICATIONS
pipe size Npt 1/4 1/4 3/8 3/8 1/2 1/2 orifice size (mm) 9,0 9,0 9,0 9,0 9,0 9,0 operating pressure differential (bar) power max. (PS) level NEMA min. 7&9 air () (m3/h) (l/min) ~/= ~/= EF flow coefficient Kv 0,68 0,68 0,68 0,68 0,68 0,68 11,3 11,3 11,3 11,3 11,3 11,3 0,0 0,0 0,0 0,0 0,0 0,0 10,0 10,0 10,0 10,0 10,0 10,0 LP BP LP BP LP BP
- Not available
IP65 EEx nA ZN SC
basic catalogue number brass B307A416 B307B016 B307A446 B307B046 B307A476 B307B076 stainless st. B307A406 B307B006 B307A436 B307B036 B307A466 B307B066
Available feature
2011/R0
SERIES 307
PREFIX TABLE
1 S E E E I N P S W W W W W W W W W W prefix 2 3 4 5 C D F V M E T S S C F V C P P D P I P Z S S D S E M S I S N F S Z N T H H N description 6 7 U Dustproof (EN 50281-1-1)* Explosionproof - NEMA 7, 9 - Zinc plated steel conduit Explosionproof - NEMA 7, 9 - 316 SS conduit Waterproof IP67 - Metal enclosure (EN/IEC 60079-7+18, 61241-1)* Threaded conduit/hole (M20 x 1,5) Intrinsically safe with SC coil (EN/IEC 60079-11+26, 61241-11)* Flameproof - Aluminium (EN/IEC 60079-1, 61241-1)* Encapsulated epoxy moulded (EN/IEC 60079-18, 61241-18)* Solenoid with spade plug connector (EN/IEC 60730) Waterproof IP67 - Metal enclosure U Waterproof IP67 - Metal enclosure, Dustproof (EN 50281-1-1)* S I.S. with Metal IP67 enclosure (EN/IEC 60079-11+26, 61241-11)* N Waterproof IP67 - Metal enclosure (EN 50021, 50281-1-1)* Waterproof IP67 - 316 SS enclosure U Waterproof IP67 - 316 SS enclosure, Dustproof (EN 50281-1-1)* Waterproof IP67 - 316 SS enclosure (EN/IEC 60079-7+18, 61241-1)* S I.S. with 316 SS IP67 enclosure (EN/IEC 60079-11+26, 61241-11)* Flameproof - 316 SS (EN/IEC 60079-1, 61241-1)* Waterproof IP67 - 316 SS enclosure (EN 50021, 50281-1-1)* Threaded conduit (1/2" NPT) C Class H - Battery charging circuit T Class H - High temperature Moulded enclosure (EN 50021, 50281-1-1)* X Other special constructions power level LP RP MP BP - -
SUFFIX TABLE
suffix 1 2 3 4 5 E J N N V V C O M B P Q M O M S M description EPDM (ethylene-propylene) CR (chloroprene) Oxygen service (CR (chloroprene)) FPM (fluoroelastomer) and parts cleaned for oxygen service FPM (fluoroelastomer) Epoxy coating on all external surfaces Mounting bracket Dry gas, non-lubricated air construction Long life, quiet operation construction Push type manual operator Screw type manual operator Metering device power level LP RP MP BP -
Available feature Available feature in DC only Available feature in AC only - Not available * ATEX solenoids are also approved according to EN 13463-1 (non electrical valves)
spare parts kit no. (1) ~ C115468 C115469 C115468 C115469 C115468 C115469 C132660 C132661 C132660 C132661 C132660 C132661 = C115472 C115473 C115472 C115473 C115472 C115473 C132660 C132661 C132660 C132661 C132660 C132661
mouting bracket no. 115292-001 115292-001 115292-001 115292-001 115292-001 115292-001 115292-001 115292-001 115292-001 115292-001 115292-001 115292-001 prefix pipe thread basic number
SC WS WP ZN
B B B B
2011/R0
SERIES 307
EXPLANATION OF TEMPERATURE RANGES OF SOLENOID VALVES
Valve temperature range Operator ambient temperature range Total temperature range The valve temperature range (TS) is determined by the selected seal material, the temperature range for proper operation of the valve and sometimes by the uid (e.g. steam) The operator ambient temperature range is determined by the selected power level and the safety code The temperature range of the complete solenoid valve is determined by the limitations of both temperature ranges above
ELECTRICAL CHARACTERISTICS
Coil insulation class Connector Connector specification Electrical safety Standard voltages: F Spade plug ISO 4400 (cable 6-10 mm) IEC 335 DC (=) 24V - 48V AC (~) 24V - 48V - 115V - 230V/50 Hz; Other voltages are available on request
operator ambient temperature range (TS) (C)(1) -40 to +75 -40 to +75 -60 to +60 -40 to +52/40 -20 to +50 -40 to +75 -40 to +75 -40 to +60 -40 to +60 -40 to +60 -20 to +50 safety code electrical enclosure protection (EN 60529) replacement coil / kit ~ 230V/50 Hz = 24V/DC 400-425-342 400-405-342 400-405-342 274-714-106D -(3) 400-929-042 400-930-042 400-930-042 123-256-001 109-496-003 -(3) 01 02 03 01 04 05 05 04 05 04 type(2)
prefix option
power ratings inrush holding hot/cold ~ ~ = (VA) (VA) (W) (W) 78 78 78 70 78 1,2 1,2 1,2 35 35 35 40 35 1,2 1,2 1,2 16,7 16,7 16,7 17,1 16,7 1,2 1,2 1,2 13,5/19,7 13,5/19,7 13,5/19,7 15,8/22,6 13,5/19,7 1,3/1,3 1,3/1,3 1,3/1,3 0,4/0,4 0,4/0,4 1,7/1,7
EN 60730 EN 60730 II2G Ex d IIC T4, II2D Ex tD NEMA type 7 and 9 II3GD EEx nA II T3 EN 60730 EN 60730 II2G Ex e mb II T6, II2D Ex tD A21 II1G Ex ia IIC T6, II2D Ex iaD 21 II1G Ex ia IIC T6, II2D Ex iaD 21 II3GD EEx nA II T3
IP65, moulded 400-425-217 IP67, steel/SS 400-405-217 IP67, alu./SS 400-405-217 4X, moulded 238-614-159D IP65, moulded -(3) IP65, moulded 400-929-097 IP67, steel/SS 400-930-097 IP67, steel/SS 400-930-097 IP65, moulded IP67, steel/SS IP65, moulded -
Temperature range can be limited by sealings Refer to the dimensional drawings on page 4
(3 ) Multiple coil kits are available under ATEX/IECEx, contact us - Not available
ADDITIONAL OPTIONS
Other pipe threads are available on request Compliance with UL, CSA and other local approvals available on request 1/2 NPT (prefix T) and M20 x 1,5 (prefix ET) conduits (aluminium or 316 SS) available for steel solenoid housing Special moulded-in solid state components for peak voltage suppression and/or rectification (four diode bridge)
INSTALLATION
The solenoid valves have to be mounted vertically and in an upright position for best performance Multi language installation/maintenance instructions are included with each valve Threaded pipe connection identifier is B = NPT (ANSI 1.20.3) Other pipe threads are available on request Ex e mb (prefix EM) execution: solenoid enclosure has a cable gland with integral strain relief for cables with an o.d. from 7 to 12 mm and is provided with an internal and external connection facility for an earthing or bonding conductor
2011/R0
SERIES 307
DIMENSIONS (mm), WEIGHT (kg)
TYPE 01:
Epoxy moulded SC: IEC 335 / ISO 4400 ZN: EN 50021, 50281-1-1
TYPE 02:
Metal, epoxy coated / AISI 316 SS WP / WS: IEC 335
L K
E F B D C
HJ
TYPE 03:
Epoxy encapsulated EF and EV: NEMA type 7, 9 / ICS-6 ANSI
TYPE 04:
Epoxy moulded SC: IEC 335 / ISO 4400 ZN: EN 50021, 50281-1-1 ISSC: EN/IEC 60079-11+26, 61241-11
L K K
E F B D C
J H
B
E F D C
HJ
TYPE 05:
Metal, epoxy coated / AISI 316 SS WP / WS: IEC 335 EM / WSEM: EN/IEC 60079-7+18, 61241-1 WPIS / WSIS: EN/IEC 60079-11+26, 61241-11
KL
EF B D C
HJ 2011/R0
SERIES 307
DIMENSIONS (mm), WEIGHT (kg)
type 01 02 03 04 05 prefix option SC, ZN WP, WS EF, EV SC, ZN, ISSC WP, WS, EM, WSEM, WPIS, WSIS power level BP BP BP LP LP A 128 134 128 134 134 B 102 102 102 102 102 C 25 25 25 25 25 D 127 127 127 127 127 E 27 27 27 27 27 F 6 6 6 6 6 G 132 130 167 153 167 H 24 24 24 24 24 J 30 30 30 30 30 K 152 168 152 154 168 L 180 180 180 180 180 weight 2,5 kg 2,5 kg 2,5 kg 2,5 kg 2,5 kg
MOUNTING BRACKETS
2011/R0
11-40-6
SERIES 307
PIC-11-0040-GB -- Availability, design and specifications are subject to change without notice. All rights reserved. 2011/R0