Known values from previous page 4000 mm plate length or stiffener length l 1000 mm plate width, stiffener spacing. s 20 mm plate thickness t Young modulus of elasticity E 200.00 Gpa x,Sd 180.00 MPa axial stress in plate and stiffener with compressive stresses as positive Since kl >= s, then kl= LG, then kg 5.59 [], where kl is buckling factor for plate between stiffeners. 13.49 [], where kG is buckling factor for plate with the stiffeners removed. Since Sd <= then: = 0.00 MPa
Known values: LG 3000 mm wfl 180 mm tfl 20 mm hw 400 mm tw 10 mm Sd 0.00 MPa M 1.15 []
web height web thickness design shear stress resulting material factor
The cross sectional area of stiffener is As and the full plate cross section area s.t = Therefore, the equivalent axial force, NSd
Note: Known values from previous page Known values Calculated values Final results
The equivalent lateral line load should be taken as: Wes and Is are determined by cross section analysis
Known values from previous page 20 mm plate thickness t 1000 mm plate width, stiffener spacing. s Se 756.41 mm the effective plate width
pSd fy
Section properties: Afl 3600 Aw 4000 Ap 20000 Apes 15128 zfl 430 zw 220 zp 10 95.22 COG dfl-es 316.52 dw-es 106.52 dpes -103.48 ces 344.78
Where: flange cross section area web cross section area plate cross section area, use s. plate cross section area, use Se. flange COG, counted from base web COG, counted from base plate COG, counted from base COG of stiffener + plate, use s. distance of zfl and COGes distance of dw and COGes distance of dp and COGpes distance from COGes to the outer fiber
Section properties: Ifl 120000 Iw 53333333 Ip 666667 Ipes 504271 dfl 334.78 dw 124.78 dp -85.22 Is 665128696 zpes 10 COGes 113.48 Ies 622003068 Wes 1804044
Where: flange cross section moment of inertia web cross section moment of inertia plate cross section moment of inertia, use s. plate cross section moment of inertia, use Se. distance of zfl and COG distance of dw and COG distance of dp and COG moment of inertia of stiffener with full plate width effective plate COG, counted from base COG of stiffener + plate, use Se. moment of inertia of stiffener with effective plate width section modulus for stiffener with effective plate at flange tip
Then, the factor kc an C0 is determined as follows: kc 62.24 [] C0 0.001446 [] 1.00 [] p0 0.0723 MPa Finally, the equivalent lateral line load, qSd qsd 223.11 N/mm
mc =13.3 for continuous stiffeners or, = 8.9 for simple supported stiffeners (sniped stiffeners)
Where: y1,Sd larger design stress in the transverse direction, with tensile stresses taken as negative y2,Sd smaller design stress in the transverse direction, with tensile stresses taken as negative