Vous êtes sur la page 1sur 45

7 FOM PLUG-IN CARD for LOOP-O9400R

STM-1/4/16(OC-3/12/48)

USER'S MANUAL

LOOP TELECOMMUNICATION INTERNATIONAL, INC. 8F, NO. 8, HSIN ANN RD. SCIENCE-BASED INDUSTRIAL PARK HSINCHU, TAIWAN Tel: 886-3-578-7696 Fax: 886-3-578-7695 LoopTelecom.com

2011 Loop Telecommunication International, Inc. All rights reserved.


Version 2 12 AUG 2011

TABLE OF CONTENTS
1 PRODUCT DESCRIPTION .........................................................................................................................1 1.1. 1.2. 2 Application .....................................................................................................................................1 Specification ...................................................................................................................................2

INSTALLATION .........................................................................................................................................3 2.1 2.2 2.3 2.4 2.5 Site Selection ..................................................................................................................................3 Mechanical Installation...................................................................................................................3 Electrical Installation ......................................................................................................................4 Optical Installation .........................................................................................................................4 LED Operation ...............................................................................................................................6

TERMINAL OPERATION ..........................................................................................................................7 3.1 3.2 3.3 Menu Tree ......................................................................................................................................7 Initial Setup and Card Registration.................................................................................................8 Choosing a Trib Unit ....................................................................................................................11

System Display ...........................................................................................................................................12 4.1 Config Display..............................................................................................................................12 4.1.1 4.1.2 4.1.3 4.1.4 4.2 4.3 4.4 4.5 Trace Message & EPSL Display.........................................................................................12 Customer Information Display............................................................................................13 TPSG Protection Mode Display..........................................................................................13 TPSG Protection Switch Display ........................................................................................14

SNCP/UPSR Status ......................................................................................................................14 SFP Information ...........................................................................................................................15 Currently-Active Alarm Summary ...............................................................................................16 Current Alarm Status ....................................................................................................................17 4.5.1 4.5.2 4.5.3 4.5.4 SDH/SONET Alarm Status.................................................................................................17 E1 Alarm Status ..................................................................................................................18 FOM Alarm Status ..............................................................................................................18 FOM Status .........................................................................................................................19

4.6 4.7 4.8

Unit Performance..........................................................................................................................21 FOM ALS/APSD Display ............................................................................................................22 Diagnostics Display......................................................................................................................23 4.8.1 4.8.2 FOM Loopback Display......................................................................................................23 E1 Diagnostics Display .......................................................................................................24

SYSETM SEUTP........................................................................................................................................25 5.1 Config Setup .................................................................................................................................25 5.1.1 5.1.2 5.1.3 5.1.4 Trace Message & EPSL Setup ............................................................................................25 Customer Information Setup ...............................................................................................26 TPSG Protection Mode Setup .............................................................................................26 TPSG Protection Switch Setup ...........................................................................................27

5.2

Unit Alarm Setup..........................................................................................................................28 5.2.1 5.2.2 5.2.3 5.2.4 5.2.5 SDH/SONET Alarm Mask and Relay Setup.......................................................................28 E1 Alarm Mask and Relay Setup ........................................................................................29 FOM Alarm Mask and Relay Setup....................................................................................29 Alarm Severity Setup ..........................................................................................................30 Insert AIS Alarm Setup.......................................................................................................30

5.3

File Transfer .................................................................................................................................31 5.3.1 5.3.2 Unit Download Firmware ...................................................................................................31 Copy Firmware to Standby Unit .........................................................................................31

5.4

SNCP/UPSR APS Command .......................................................................................................32 5.4.1 5.4.2 SNCP/UPSR APS Command..............................................................................................32 SNCP/UPSR Revertive Setup .............................................................................................33

5.5

Performance Setup/Clear ..............................................................................................................34 5.5.1 5.5.2 Clear Performance Data ......................................................................................................34 Performance Threshold Setup .............................................................................................34

5.6

Loopback & Diagnostics Setup ....................................................................................................35 5.6.1 5.6.2 5.6.3 5.6.4 5.6.5 FOM Loopback Setup .........................................................................................................36 FOM Remote Loopback Setup............................................................................................37 E1 Loopback Setup .............................................................................................................38 E1 Remote Loopback Setup................................................................................................39 E1 Diagnostics Setup ..........................................................................................................40

5.7

FOM ALS/APSD Setup................................................................................................................41

LIST OF TABLES
Table 2-1 LED Indication.....................................................................................................................................6

LIST OF FIGURES
Figure 2-1 7FOM Panel View .............................................................................................................................3 Figure 2-2 SFP module Figure 2-3 Optical Cable...............................................4

Figure 2-4 FOM port with SFP module ..........................................................................................................4 Figure 2-5 FOM port with SPF module and optical cable ...........................................................................5 Figure 3-1 Menu Tree .......................................................................................................................................7 Figure 5-1 7 FOM Loopback Diagram..........................................................................................................35

CHAPTER 1 PRODUCT DESCRIPTION

PRODUCT DESCRIPTION

The Loop-O9400R 7 FOM card is a high-speed module that can connect with the O9400R-XCU4, O9400R-XCU16, O9500R, AM3440 series and O9310-E1 using Loop proprietary FOM (Fiber Optical Modulator) interface. Each card has 7 FOM interfaces. Each FOM interface supports up to 4 E1 aggregate channels. The 7 FOM card is E1 mode configurable and supports Tributary Line 1+1 Protection. When protection enable with 1+1, both O9400R-CC4 and O9400R-CC16 can support up to 28 ports of FOM. Without protection, the O9400R-CC16 can support up to 56 ports of FOM and the O9400R-CC4 can support up to 42 ports of FOM.

1.1.

Application

CHAPTER 1 PRODUCT DESCRIPTION

1.2.

Specification

Fiber Optical Interface Port number 7 Source Laser Wavelength 1310 50 nm, 1550 40 nm Optical Line Rate 38.84Mbps Connector SFP housing with LC type Reach 2~240 Km For more detail, please refer to the SFP Optical modules Brochure Diagnostics Test Optical Fiber E1 Link

Line Code

Scrambled NRZ

Protection

1+1 Card Protection

Local and remote loopbacks Local and remote loopback, send test pattern

CHAPTER 2 INSTALLATION

2 INSTALLATION
2.1 Site Selection
The following list indicates a site selection guideline. Users need to follow this guideline to select a proper installation site. Location of the Rack should be part of the central office equipment layout design. Considerations should be given to entrance cable routing and -48 Vdc power. The installation site should have -48 Vdc power. An optional AC/DC power converter can be used. Use only with Class 2 power source, -48 Vdc, 100 watts.

2.2 Mechanical Installation


The 7-port FOM card can be plugged into any of the TRIB slots (slot 1~8) in the O9400R chassis. The front panel is shown in the figure below:

Figure 2-1 7FOM Panel View

CHAPTER 2 INSTALLATION

2.3 Electrical Installation


All electrical connections are on the backplane. The electrical connections are made when the card is firmly seated into a tributary slot in the O9400 chassis. 7 FOM cards are hot swappable.

2.4 Optical Installation


The 7 FOM card supports up to seven fiber connections. To set up an optical line, a SFP module and an optical cable are required.

Figure 2-2 SFP module

Figure 2-3 Optical Cable

First, plug the SFP module into the FOM port you wish to setup.

Figure 2-4 FOM port with SFP module

CHAPTER 2 INSTALLATION

Then, plug the optical cable into the SFP module. The LED light will turn from red to green. The optical installation is now complete.

Figure 2-5 FOM port with SPF module and optical cable

CHAPTER 2 INSTALLATION

2.5 LED Operation


The following table lists the 7-FOM port LED function, color, and indications. LED ACT Off Flashing Green Color Indication Card failure Working card: under normal operation Flashing Amber ALM(ALM) Red Standby card (protection) Critical or Major alarm detected Note: This LED will be Amber disabled when the Alarm Mask function is set as OFF under Green VT100 operation. TEST Flashing Amber Minor alarm detected Info alarm or no alarm Loopback test in progress

LED Indication for Each Port (P1 to 7) SYNC/TEST Flashing Green Green RAI LOS/LOF Yellow Red Table 2-1 LED Indication Loopback in progress SYNC in progress Detecting an RAI alarm Detecting LOS/LOF alarm

CHAPTER 3 TERMINAL OPERATION

3 TERMINAL OPERATION

3.1 Menu Tree

Figure 3-1 Menu Tree

CHAPTER 3 TERMINAL OPERATION

3.2

Initial Setup and Card Registration

Prior to setting up an FOM interface card, you must first set up the main O9400R-XCU16 or O9400R device. Full instructions for doing so are found in the O9400R-XCU16 or O9400R Users Manual. After that setup is complete, go to the main Controller Menu for the O9400R-XCU16 or O9400R device. The O9400R-XCU16 sample screens are shown below.

You must register your 7FOM cards with the O9400R-XCU16 device. Note: The O9400R chassis type will appear in the top left-hand corner of the screen. (See highlighting in the sample screen below.)
O9400R-XCU16 === Controller Menu === 11:21:53 10/21/2010

Serial Number : 007741 Hardware Version: B Software Version: V1.05.01 10/19/2010 [DISPLAY] C -> System Config Display D -> SDH/SONET Config Display I -> System Information Q -> Alarm Queue B -> Currently-Active Alarm Summary A -> Current Alarm Status P -> SDH/SONET Performance T -> System Log E -> Diagnostics Display [LOG] F -> Log Off O -> Log On U -> Choose a Trib Unit

Device Name : DEVICE 1 Start Time : 10:37:54 10/21/2010 Connect Port: SUPV_PORT [SETUP] S -> System Config Setup H -> SDH/SONET Config Setup M -> Alarm Setup L -> File Transfer V -> Store/Retrieve Backup Config G -> Loopback/Diagnostics Setup R -> Performance Setup/Clear N -> Unit Registration

[MISC] Y -> Alarm Cut Off Z -> Reset X -> Clear Alarm Queue W -> Return to Default

>>SPACE bar to refresh or enter a command ===>

Press N> Unit Registration from the Controller Menu. The Unit Registration screen will appear. Select the command Card Registration and press the Enter key.
O9400R-XCU16 === Unit Registration === 11:23:01 10/21/2010 ARROW KEYS: CURSOR MOVE, TAB/`: ROLL UP/DOWN OPTIONS

SL. REG. Model/Mode Card Model Software Version Remark === ===================== ================ =================== ============= #1 7FOM V1.01.01 08/26/2010 #2 7FOM V1.01.01 08/26/2010 #3 #4 #5 #6 #7 #8 (PRTD = Protected, NP = No Protection) Command : Card Registration

<< Press ESC key to return to previous menu >>


8

CHAPTER 3 TERMINAL OPERATION

Use the Tab key to scroll in the Tributary slot that your 7 FOM card is plugged into. Press the Enter key.
Command Unit : Card Registration : Trib-1

The model of card will appear. Move the cursor to the Registered Model field and select the protection type. NP= Not Protected. PRTD=Protected. In the sample screen below, we choose 7FOM-PRTD:
Command : Card Registration Unit : Trib-1 REG. Model/Mode : 7FOM-PRTD Registration...... << Press ESC key to return to previous menu >>

Press the Enter key. A registration prompt will appear as the registration takes place.

Registration......SUCCESS!

CHAPTER 3 TERMINAL OPERATION

After registration, the card information will show on the screen:


O9400R-XCU16 === Unit Registration === ARROW KEYS: CURSOR MOVE, TAB/`: ROLL UP/DOWN OPTIONS 11:23:01 10/21/2010

SL. REG. Model/Mode Card Model Software Version Remark === ===================== ================ =================== ============= #1 7FOM V1.01.01 08/26/2010 #2 7FOM V1.01.01 08/26/2010 #3 #4 #5 #6 #7 #8 (PRTD = Protected, NP = No Protection)

Command

: Card Registration

<< Press ESC key to return to previous menu >>

If you have other cards to register do it now. Each plug-in interface card must be registered separately.

Accept Current Port Number: This function is only available for the E1 plug-in card. Please do not choose this setting because it is meaningless for the 7 FOM card.

Change Protection Mode: To change the protection mode, you do not need to de-register the card. Simply use the command Change Protection Mode. You can change the cards protection mode from NP (without protection) to PRTD (with protection), or vise-versa.

Card De-registration: To de-register a card, please activate the command Card Un-registration. The setup procedure is similar to that of Card registration.

10

CHAPTER 3 TERMINAL OPERATION

3.3

Choosing a Trib Unit

Press U from the O9400R-XCU16 Controller Menu to select the Tributary slot that the 7FOM card is plugged into. A prompt will appear. Use the Tab key to scroll in the cards Tributary slot number. Press the Enter key.
==>> Press Tab key to select the unit: 1

The unit menu will show as below:


Unit 1 7FOM === Unit Menu === 18:14:53 06/15/2010

HW Version : C SW Version : V1.01.01 06/11/2010

Card State : Initialization Completed TPSG Working :

[DISPLAY] C -> Config Display B -> SNCP/UPSR Status I -> SFP Information Q -> Currently-Active Alarm Summary A -> Current Alarm Status P -> Unit Performance D -> FOM ALS/APSD Display K -> Diagnostics Display [LOG] F -> Log Off O -> Log On U -> Choose a Unit E -> Return to Main Menu

[SETUP] S -> Config Setup M -> Unit Alarm Setup L -> File Transfer N -> SNCP/UPSR APS Command R -> Performance Setup/Clear G -> Loopback & Diagnostics Setup H -> FOM ALS/APSD Setup

[MISC] Z -> Unit Reset W -> Unit Load Default

>>SPACE bar to refresh or enter a command ===>

11

CHAPTER 4 System Display

4 System Display

4.1 Config Display

4.1.1 Trace Message & EPSL Display

Command Path: Unit Menu> (C) Config Display > (A) Trace Message & EPSL Display Function: Key in the FOM port and E1 channel number, and press Enter.
Unit 1 7FOM === Trace Message & EPSL Display === 15:01:06 06/18/2010 ARROW KEYS: CURSOR MOVE, Please Input: 1~4, BACKSPACE to edit

FOM Port : 1 E1 Channel: 1

The current status of the trace message and EPSL will show on the screen:
Unit 1 7FOM === Trace Message & EPSL Display === 15:01:06 06/18/2010 ARROW KEYS: CURSOR MOVE, Please Input: 1~4, BACKSPACE to edit

FOM Port : 1 E1 Channel: 1 =============================== Trace Message ============================== J2_LEN : NULL ============================== TX PSL and EPSL ============================= LP_EPSL : 02 ( Asynchronous ) LP_TX_PSL : 02 ( Asynchronous ) LP_RX_PSL : 03 ( Bit Synchronous )

<< ESC key to return to previous menu, SPACE bar to refresh >>

12

CHAPTER 4 System Display

4.1.2 Customer Information Display

Command Path: Unit Menu> (C) Config Display > (B) Customer Information Display Function: The screen shows the name and contact information of the customer for each port.
Unit 1 7FOM === Customer Information Display === 15:13:51 06/18/2010

FOM# 1 2 3 4 5 6 7

Customer Information name of link#1 name of link#2 name of link#3 name of link#4 name of link#5 name of link#6 name of link#7

<< ESC key to return to previous menu, SPACE bar to refresh >>

4.1.3 TPSG Protection Mode Display

Command Path: Unit Menu> (C) Config Display > (C) TPSG Protection Mode Display Function: The screen shows the current TPSG protection type and mode.
Unit 1 7FOM === TPSG Protection Mode Display === 15:33:13 06/18/2010

TPSG Protection Type: Line(1+1) TPSG Protection Mode: Non-revertive

<< ESC key to return to previous menu, SPACE bar to refresh >>

13

CHAPTER 4 System Display

4.1.4 TPSG Protection Switch Display

Command Path: Unit Menu> (C) Config Display > (D) TPSG Protection Switch Display Function: The screen shows the working line side (left, right) for each of the FOM port.
Unit 1 7FOM === TPSG Protection Switch Display === 15:40:34 06/18/2010

FOM# 1 2 3 4 5 6 7

Working Line Side Left Left Left Left Left Left Left

<< ESC key to return to previous menu, SPACE bar to refresh >>

4.2 SNCP/UPSR Status


Command Path: Unit Menu> (B) SNCP/UPSR Status Function: The screen shows the current and primary path for each port in SNCP/UPSR setup.
Unit 1 7FOM PORT#6 === SNCP/UPSR Status === 18:47:28 08/12/2010

Port-Channel ============= 6 - 1 6 - 2 6 - 3 6 - 4

Current.Path Primary.Path P.P Type Command ===================================================== XCU1(W)-P1 XCU1(W)-P1 PP-A&D Clear XCU1(W)-P1 XCU1(W)-P1 PP-A&D Clear XCU1(W)-P1 XCU1(W)-P1 PP-A&D Clear XCU1(W)-P1 XCU1(W)-P1 PP-A&D Clear

<< ESC key to return, ARROW KEYS to change path >>

14

CHAPTER 4 System Display

4.3 SFP Information


Command Path: Unit Menu> (I) SFP Information Function: Key in the port number and press Enter:
Unit 1 7FOM === SFP Information === 16:29:24 06/18/2010 ARROW KEYS: CURSOR MOVE, Please Input: 1~7, BACKSPACE to edit

FOM Port: 1

The screen will show the configuration of that particular port.


Unit 1 7FOM === SFP Information === 16:29:24 06/18/2010 ARROW KEYS: CURSOR MOVE, Please Input: 1~7, BACKSPACE to edit

FOM Port: 1

[------------ FOM PORT#1 ------------] Connector : LC Transceiver : OC 12, single mode inter. Link Length : Not available Technology : Not available Encoding : Not available Length(9/125 mm fiber) : 20000 m Length(50/125 mm fiber) : ---Length(62.5/125 mm fiber) : ---Length(copper) : ----

<< ESC key to return to previous menu, SPACE bar to refresh >>

15

CHAPTER 4 System Display

4.4 Currently-Active Alarm Summary


Command Path: Unit Menu> (Q) Currently-Active Alarm Summary Function: Display the current active alarms
Unit 1 7FOM === Currently-Active Alarm Summary === 16:53:13 08/12/2010

1 MAJR>Unit#3 Port#1 Channel#1 TU-AIS 2 MAJR>Unit#3 Port#1 Channel#2 TU-AIS 3 MAJR>Unit#3 Port#1 Channel#3 TU-AIS 4 MAJR>Unit#3 Port#1 Channel#4 TU-AIS 5 MAJR>Unit#3 Port#1 Channel#1 E1-AIS 6 MAJR>Unit#3 Port#1 Channel#2 E1-AIS 7 MAJR>Unit#3 Port#1 Channel#3 E1-AIS 8 MAJR>Unit#3 Port#1 Channel#4 E1-AIS 9 MAJR>Unit#3 Port#2 LOS 10 MAJR>Unit#3 Port#2 Channel#1 TU-AIS 11 MAJR>Unit#3 Port#2 Channel#2 TU-AIS 12 MAJR>Unit#3 Port#2 Channel#3 TU-AIS 13 MAJR>Unit#3 Port#2 Channel#4 TU-AIS 14 MAJR>Unit#3 Port#2 Channel#1 E1-AIS 15 MAJR>Unit#3 Port#2 Channel#2 E1-AIS 16 MAJR>Unit#3 Port#2 Channel#3 E1-AIS 17 MAJR>Unit#3 Port#2 Channel#4 E1-AIS 18 MAJR>Unit#3 Port#3 LOS 19 MAJR>Unit#3 Port#3 Channel#1 TU-AIS 20 MAJR>Unit#3 Port#3 Channel#2 TU-AIS

<<Press SPACE bar to change or ESC key to return to Main Menu>>

16

CHAPTER 4 System Display

4.5 Current Alarm Status

4.5.1 SDH/SONET Alarm Status

Command Path: Unit Menu> (A) Current Alarm Status > (A) SDH/SONET Alarm Status Function: Display the SDH/SONET alarm for Each FOM port and E1 channel. First, Key in the FOM port and E1 channel number. Then, press Enter:
Unit 1 7FOM === SDH/SONET Alarm Status === 16:34:32 06/18/2010 ARROW KEYS: CURSOR MOVE, Please Input: 1~7, BACKSPACE to edit

FOM Port : 1 E1 Channel: 1

The alarm type and status will show on the screen:


Unit 1 7FOM === SDH/SONET Alarm Status === 18:50:08 08/12/2010 ARROW KEYS: CURSOR MOVE, Please Input: 1~4, BACKSPACE to edit FOM Port : 1 E1 Channel: 1 Type -------TU-LOP TU-AIS LP-UNEQ LP-PLM LP-TIM LP-RDI-P LP-RDI-S LP-RDI-C LP-REI LP-BIP Status -------Clear Active ABS Clear Clear Clear Clear Clear ABS ABS

<< ESC key to return to previous menu, SPACE bar to refresh >>

17

CHAPTER 4 System Display

4.5.2 E1 Alarm Status

Command Path: Unit Menu> (A) Current Alarm Status > (B) E1 Alarm Status Function: Display the E1 alarm for Each FOM port and E1 channel. First, Key in the FOM port and E1 channel number. Then, press Enter. The E1 alarm status will show on the screen.
Unit 1 7FOM === E1 Alarm Status === 18:50:49 08/12/2010 ARROW KEYS: CURSOR MOVE, Please Input: 1~7, BACKSPACE to edit FOM Port : 1 E1 Channel: 1 Type Status -------- -------AIS Active

<< ESC key to return to previous menu, SPACE bar to refresh >>

4.5.3 FOM Alarm Status

Command Path: Unit Menu> (A) Current Alarm Status > (C) FOM Alarm Status Function: Display the FOM alarm for Each FOM port. First, Key in the FOM port number. Then, press Enter. The FOM alarm status will show on the screen.
Unit 1 7FOM === FOM Alarm Status === 16:41:16 06/18/2010 ARROW KEYS: CURSOR MOVE, Please Input: 1~7, BACKSPACE to edit FOM Port: 1

Type -------LOS LOF RAI UAS

Status -------Active ABS Clear ABS

<< ESC key to return to previous menu, SPACE bar to refresh >>

18

CHAPTER 4 System Display

4.5.4 FOM Status

Command Path: Unit Menu> (A) Current Alarm Status > (D) FOM Status Function: Display the FOM alarm for Each FOM port. First, Key in the FOM port number. Then, press Enter. The status of the local and remote FOM interface will show on the screen. The remote interface can be a FOM card on O9500R, O9400R-XCU16, a FOM card on AM3440, O9310 FOM with CPU, and O9310 FOM without CPU. Sample screens are shown as below. With Remote O9500/O9400R-XCU16 FOM card:
Unit 1 7FOM FOM Port: 3 ==== Local FOM Interface Status ==== Interface Type: 7FOM LOF : NO Framing error : 0 Checksum error: 0 ==== Remote FOM Interface Status ==== Interface Type: 7FOM LOF : NO Framing error : 0 Checksum error: 0 === FOM Status === 10:47:15 07/29/2010

<< ESC key to return to previous menu, SPACE bar to refresh >>

With Remote AM3440 FOM card:


Unit 3 7FOM FOM Port: 1 ==== Local FOM Interface Status ==== Interface Type: 7FOM LOF : NO Framing error : 0 Checksum error: 0 ==== Remote FOM Interface Status ==== Interface Type: MUX FOM LOF : NO Framing error : 0 Checksum error: 0 === FOM Status === 10:16:31 07/29/2010

==== Remote E1 Interface Status ==== E1# LOF CRC error 1 YES 0 2 YES 0 3 YES 0 4 YES 0

<< ESC key to return to previous menu, SPACE bar to refresh >>
19

CHAPTER 4 System Display

Remote O9310 without CPU FOM:


Unit 1 7FOM FOM Port: 1 ==== Local FOM Interface Status ==== Interface Type: 7FOM LOF : NO Framing error : 18 Checksum error: 0 ==== Remote FOM Interface Status ==== Interface Type: CPE FOM without CPU LOF : NO Framing error : 0 Checksum error: 0 === FOM Status === 10:21:20 07/29/2010

==== Remote E1 Interface Status ==== E1# LOS BPV error 1 NO 0 2 YES 0 3 YES 0 4 YES 0

<< ESC key to return to previous menu, SPACE bar to refresh >>

Remote O9310 with CPU:


Unit 3 7FOM FOM Port: 1 ==== Local FOM Interface Status ==== Interface Type: 7FOM LOF : NO Framing error : 0 Checksum error: 0 ==== Remote FOM Interface Status ==== Interface Type: CPE FOM with CPU LOF : NO Framing error : 0 Checksum error: 0 === FOM Status === 10:23:12 07/29/2010

==== Remote E1 Interface Status ==== E1# LOS BPV error 1 NO 0 2 NO 0 3 NO 0 4 YES 0

<< ESC key to return to previous menu, SPACE bar to refresh >>

20

CHAPTER 4 System Display

4.6 Unit Performance


In the Unit Performance section, you can view the 7FOM card performance under two categories: SDH/SONET performance and FOM performance. Each category contains 15-Min/01-Hour, 15-Min/24-Hour, and 01-Day/07-Day performance report. SDH/SONET Performance Report: Below is the sample display procedure of SDH/SONET performance: 1. Select the performance type you need. Here, we select (1) 15-Min/01-Hour Performance Report. 2. Key in the FOM port number and the E1 channel for display:
Unit 1 7FOM === 15-Min/01-Hour Performance Report === 18:15:02 06/18/2010 ARROW KEYS: CURSOR MOVE, Please Input: 1~7, BACKSPACE to edit

FOM Port : 1 E1 Channel: 1

3. Select the Anomaly Type: LP-BIP(V5), or LP-REI(V5) and press Enter.


Anomaly Type : LP-BIP(V5)

4. For 15-Min/24-Hour Performance Report, youll also have to select the parameter type: UAS, BES, SES, EB, BBE, ES
Parameter : UAS

5. The performance report for the current, 1st, 2nd, 3rd and 4th nearest time interval of each parameter will show on the screen as below:
Unit 1 7FOM === 15-Min/01-Hour Performance Report === 18:16:37 06/18/2010

LP-BIP(V5) PORT#1 CHANNEL#1 -- Valid Seconds in Current 15-Min Interval : 102 seconds

(EB) (BBE) Current 15-Min Interval : 0 0 1st Nearest 15-Min Interval : 0 0 2nd Nearest 15-Min Interval : 0 0 3rd Nearest 15-Min Interval : 0 0 4th Nearest 15-Min Interval : 0 0

(ES) 0 0 0 0 0

(UAS) (BES) 102 0 900 0 900 0 900 0 900 0

(SES) 0 0 0 0 0

<< TAB key to show Statistics Report >> << ESC key to return to previous menu, SPACE bar to refresh >>

FOM Performance Report Below is the sample display procedure of FOM performance: 1. Select the performance type you need. Here, we select (4) 15-Min/01-Hour Performance Report.

21

CHAPTER 4 System Display

2. Key in the FOM port number for display:


Unit 1 7FOM === 15-Min/01-Hour Performance Report ===18:28:08 06/18/2010 ARROW KEYS: CURSOR MOVE, Please Input: 1~7, BACKSPACE to edit

FOM Port: 1

3. Select the Anomaly Type: LINE and press Enter.


Anomaly Type : LP-BIP(V5)

4. For 15-Min/24-Hour Performance Report, youll also have to select the parameter type: UAS, BES, SES, CV, ES
Parameter : UAS

5. The performance report for the current, 1st, 2nd, 3rd and 4th nearest time interval of each parameter will show on the screen as below:
Unit 1 7FOM === 15-Min/01-Hour Performance Report === 18:28:42 06/18/2010 LINE PORT#1 -- Valid Seconds in Current 15-Min Interval : 828 seconds

(ES) (UAS) (BES) Current 15-Min Interval : 0 828 0 1st Nearest 15-Min Interval : 0 900 0 2nd Nearest 15-Min Interval : 0 900 0 3rd Nearest 15-Min Interval : 0 900 0 4th Nearest 15-Min Interval : 0 900 0 << TAB key to show Statistics Report >>

(SES) 0 0 0 0 0

(CV) 0 0 0 0 0

<< ESC key to return to previous menu, SPACE bar to refresh >>

4.7 FOM ALS/APSD Display


Command Path: Unit Menu> (D) ALS/APSD Display Function: Display the ALS/APSD status for Each FOM port.
Unit 1 7FOM === FOM ALS/APSD Display === 18:30:57 06/18/2010

ALS enable : OFF Pulse repetition time for automatic restart(sec) : 300 FOM FOM FOM FOM FOM FOM FOM FOM FOM FOM FOM FOM FOM FOM P1 P2 P3 P4 P5 P6 P7 P1 P2 P3 P4 P5 P6 P7 power power power power power power power down: down: down: down: down: down: down: OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF

manual manual manual manual manual manual manual

restart: restart: restart: restart: restart: restart: restart:

<< ESC key to return to previous menu, SPACE bar to refresh >>

22

CHAPTER 4 System Display

4.8 Diagnostics Display

4.8.1 FOM Loopback Display

Command Path: Unit Menu> (K) Diagnostics Display > (A) FOM Loopback Display Function: Display local and remote loopback status for Each FOM port.
Unit 1 7FOM === FOM Loopback Display === 18:43:50 06/18/2010

Port Loopback Remote Loopback ----- -------- --------------1 OFF OFF 2 OFF OFF 3 OFF OFF 4 OFF OFF 5 OFF OFF 6 OFF OFF 7 OFF OFF

<< ESC key to return to previous menu, SPACE bar to refresh >>

23

CHAPTER 4 System Display

4.8.2 E1 Diagnostics Display

Command Path: Unit Menu> (K) Diagnostics Display > (B) E1 Diagnostics Display Function: Display the E1 Diagnostics report for each channel
Unit 1 7FOM === E1 Diagnostics Display === 18:59:12 08/12/2010 Port- Loopback Port- Loopback Chan Local/Remote Test Pattern Chan Local/Remote Test Pattern ---- ------------- ------------------- ---- ------------- ------------------1-1 OFF/OFF <No Test Pattern> 5-1 OFF/OFF <No Test Pattern> 1-2 OFF/OFF <No Test Pattern> 5-2 To FOM/OFF <No Test Pattern> 1-3 OFF/OFF <No Test Pattern> 5-3 OFF/OFF <No Test Pattern> 1-4 OFF/OFF <No Test Pattern> 5-4 OFF/OFF <No Test Pattern> 2-1 2-2 2-3 2-4 OFF/OFF To BP/OFF To FOM/OFF OFF/OFF <System side,2^20-1> <No Test Pattern> <No Test Pattern> <No Test Pattern> <No Test Pattern> <No Test Pattern> <No Test Pattern> <No Test Pattern> 6-1 OFF/OFF 6-2 To BP/OFF 6-3 To FOM/OFF 6-4 OFF/OFF 7-1 OFF/OFF 7-2 To BP/OFF 7-3 To FOM/OFF 7-4 OFF/OFF <No <No <No <No Test Test Test Test Pattern> Pattern> Pattern> Pattern>

3-1 OFF/OFF 3-2 To BP/OFF 3-3 OFF/OFF 3-4 To FOM/OFF

<System side,2^15-1> <No Test Pattern> <No Test Pattern> <No Test Pattern>

4-1 OFF/OFF <No Test Pattern> (To BP = To Backplane) 4-2 OFF/OFF <No Test Pattern> 4-3 To BP/OFF <No Test Pattern> 4-4 OFF/OFF <No Test Pattern> << ESC key to return to previous menu, SPACE bar to refresh >>

24

CHAPTER 5 SYSETM SEUTP

5 SYSETM SEUTP

5.1 Config Setup

5.1.1 Trace Message & EPSL Setup

Command Path: Unit Menu > (S) Config Setup > (A) Trace Message & EPSL Setup Configuration: Field FOM Port E1 Channel 1~7 1~4 Trace Message J2_LEN Null 16-BYTE(NULL Padding) 16-BYTE(Space Padding) EXP_J2_MSG: TX_J2_MSG : Setup by Users Setup by Users TX PSL and EPSL LP_EPSL LP_TX_PSL 0~7 0~7 2 2 Null Setting Options 1 1 Default

How to Set up Key-in the FOM port and E1 channel number. Press Enter. Then, set up the trace message and TX PSL and EPSL configuration you need.
Unit 1 7FOM === Trace Message & EPSL Setup === ARROW KEYS: CURSOR MOVE, TAB/`: ROLL UP/DOWN OPTIONS FOM Port : 1 E1 Channel: 1 15:22:47 06/21/2010

=============================== Trace Message ============================== J2_LEN : NULL

============================== TX PSL and EPSL ============================= LP_EPSL : 2 ( Asynchronous ) LP_TX_PSL : 2 ( Asynchronous )

<< Press ESC key to return to previous menu >>

25

CHAPTER 5 SYSETM SEUTP

5.1.2 Customer Information Setup

Command Path: Unit Menu > (S) Config Setup > (B) Customer Information Setup How to Set up: Key-in the customer information for each port, then, press Enter to save the configuration.
Unit 1 7FOM === Customer Information Setup === 16:11:18 06/21/2010 ARROW KEYS: CURSOR MOVE, BACKSPACE to edit, ESC to abort

FOM# 1 2 3 4 5 6 7

Customer Information name of link#1__________________________________________________ name of link#2 name of link#3 name of link#4 name of link#5 name of link#6 name of link#7

>> Change configuration (Y/N)? (Note:to save,please use V-command) << Press ESC key to return to previous menu >>

5.1.3 TPSG Protection Mode Setup

Command Path: Unit Menu > (S) Config Setup > (C) TPSG Protection Mode Setup Configuration: Field TPSG Protection Type TPSG Protection Mode Setting Option Line 1+1 Revertive, Non-revertive Line 1+1 Non-revertive Default

How to Set up:


Unit 1 7FOM === TPSG Protection Mode Setup === ARROW KEYS: CURSOR MOVE, TAB/`: ROLL UP/DOWN OPTIONS 16:16:34 06/21/2010

TPSG Protection Type: Line(1+1) TPSG Protection Mode: Non-revertive

<< Press ESC key to return to previous menu >>

26

CHAPTER 5 SYSETM SEUTP

5.1.4 TPSG Protection Switch Setup

Command Path: Unit Menu > (S) Config Setup > (D) TPSG Protection Switch Setup Configuration: Field FOM port #1~7 How to Set up: Select the working line side for each port. Then, press Enter to save the configuration.
Unit 1 7FOM === TPSG Protection Switch Setup === ARROW KEYS: CURSOR MOVE, TAB/`: ROLL UP/DOWN OPTIONS 17:24:49 06/21/2010

Setting Option Left, right Left

Default

FOM# 1 2 3 4 5 6 7

Working Line Side Left Left Left Left Left Left Left

<< Press ESC key to return to previous menu >>

27

CHAPTER 5 SYSETM SEUTP

5.2 Unit Alarm Setup

5.2.1 SDH/SONET Alarm Mask and Relay Setup

Command Path: Unit Menu > (M) Unit Alarm Setup > (A) SDH/SONET Alarm Mask and Relay Setup How to Set up: Select the working line side for each port. Then, press Enter to save the configuration.
Unit 1 7FOM === SDH/SONET Alarm Mask & Relay Setup ==10:19:09 06/22/2010 ARROW KEYS: CURSOR MOVE, TAB/`: ROLL UP/DOWN OPTIONS FOM Port : 1 E1 Channel: 1

Unit 1 7FOM === SDH/SONET Alarm Mask & Relay Setup ==10:19:09 06/22/2010 ARROW KEYS: CURSOR MOVE, TAB/`: ROLL UP/DOWN OPTIONS FOM Port : 1 E1 Channel: 1 type -------TU-LOP TU-AIS LP-UNEQ LP-PLM LP-TIM LP-RDI-P LP-RDI-S LP-RDI-C LP-REI LP-BIP alarm relay -------- -------DISABLED DISABLED DISABLED DISABLED DISABLED DISABLED DISABLED DISABLED DISABLED DISABLED DISABLED DISABLED DISABLED DISABLED DISABLED DISABLED DISABLED DISABLED DISABLED DISABLED

<< Press ESC key to return to previous menu >>

28

CHAPTER 5 SYSETM SEUTP

5.2.2 E1 Alarm Mask and Relay Setup

Command Path: Unit Menu > (M) Unit Alarm Setup > (B) E1 Alarm Mask and Relay Setup How to Set up: Select the FOM port and E1 channel number. Then, press ENTER.
Unit 1 7FOM === E1 Alarm Mask & Relay Setup === ARROW KEYS: CURSOR MOVE, TAB/`: ROLL UP/DOWN OPTIONS FOM Port : 1 E1 Channel: 1 11:23:27 06/23/2010

Select Enable or Disable for the AIS alarm and alarm relay. Then, press ENTER to confirm with the setting.
Unit 1 7FOM === E1 Alarm Mask & Relay Setup === ARROW KEYS: CURSOR MOVE, TAB/`: ROLL UP/DOWN OPTIONS FOM Port : 1 E1 Channel: 1 type alarm relay -------- -------- -------AIS DISABLED DISABLED 11:23:27 06/23/2010

<< Press ESC key to return to previous menu >>

5.2.3 FOM Alarm Mask and Relay Setup

Command Path: Unit Menu > (M) Unit Alarm Setup > (C) FOM Alarm Mask and Relay Setup How to Set up: Select the FOM port number. Then, press ENTER.
Unit 1 7FOM === FOM Alarm Mask & Relay Setup === 14:48:53 06/23/2010 ARROW KEYS: CURSOR MOVE, TAB/`: ROLL UP/DOWN OPTIONS FOM Port: 1

Select Enable or Disable for the LOS, LOF, RAI and UAS alarm and alarm relay. Then, press ENTER to confirm with the setting.
Unit 1 7FOM === FOM Alarm Mask & Relay Setup === 14:48:53 06/23/2010 ARROW KEYS: CURSOR MOVE, TAB/`: ROLL UP/DOWN OPTIONS FOM Port: 1 type -------LOS LOF RAI UAS alarm relay -------- -------ENABLED DISABLED ENABLED DISABLED ENABLED DISABLED ENABLED DISABLED

<< Press ESC key to return to previous menu >>


29

CHAPTER 5 SYSETM SEUTP

5.2.4 Alarm Severity Setup

Command Path: Unit Menu > (M) Unit Alarm Setup > (C) Alarm Severity Setup How to Set up: Select the severity level major, minor, inform, critical for each alarm. Then, press ENTER to confirm with the setting.
Unit 1 7FOM === Alarm Severity Setup === ARROW KEYS: CURSOR MOVE, TAB/`: ROLL UP/DOWN OPTIONS 15:24:46 06/23/2010

LP Path Severity --------------------TU-LOP MAJOR TU-AIS MAJOR LP-UNEQ MINOR LP-PLM MINOR LP-TIM MINOR LP-RDI-P MINOR LP-RDI-S MINOR LP-RDI-C MINOR LP-REI MINOR LP-BIP MINOR

E1 Severity --------------------AIS MAJOR

FOM Severity --------------------LOS MAJOR LOF MINOR RAI MINOR UAS MINOR

<< Press ESC key to return to previous menu >>

5.2.5 Insert AIS Alarm Setup

Command Path: Unit Menu > (M) Unit Alarm Setup > (D) Insert AIS Alarm Setup How to Set up: You can insert LO-UNEQ, LP-TIM or LP-PLM to AIS alarm. Select Enable or Disable for each option, then, press ENTER to confirm with the setting.
Unit 1 7FOM === Insert AIS Alarm Setup === ARROW KEYS: CURSOR MOVE, TAB/`: ROLL UP/DOWN OPTIONS 15:50:24 06/23/2010

Type Alarm -------------- -------LP-UNEQ to AIS ENABLE LP-TIM to AIS ENABLE LP-PLM to AIS ENABLE

<< Press ESC key to return to previous menu >>

30

CHAPTER 5 SYSETM SEUTP

5.3 File Transfer

5.3.1 Unit Download Firmware

Command Path: Unit Menu > (L) File Transfer > (A) Unit Download Firmware How to Set up: Key in the TFTP server IP and firmware file name. Press ENTER to download the firmware.
Unit 1 7FOM === Unit Download Firmware === 16:29:00 06/23/2010 ARROW KEYS: CURSOR MOVE, Please Input: nnn.nnn.nnn.nnn, BACKSPACE to edit Firmware 1 Version : V1.01.01 06/11/2010 Firmware 2 Version : V1.01.01 06/11/2010 Current Firmware Bank: 2 Next Boot Firmware : 2 TFTP Server IP : 000.000.000.000 Firmware File Name :

<< Press ESC key to abort, ENTER key to Upload/Download Firmware >>

5.3.2 Copy Firmware to Standby Unit

Command Path: Unit Menu > (L) File Transfer > (B) Copy Firmware to Standby Unit How to Set up: On the screen, a prompt will ask if you are sure to copy firmware to standby unit. Press Y to confirm.
Copy firmware to standby unit - are you sure ?

31

CHAPTER 5 SYSETM SEUTP

5.4 SNCP/UPSR APS Command


Command Path: Unit Menu > (N) SNCP/UPSR APS Setup The SNCP/UPSR APS Setup screen will appear. Press A or B.
Unit 6 7FOM === SNCP/UPSR APS Setup === 17:02:22 08/03/2011

A -> SNCP/UPSR APS Command B -> SNCP/UPSR Revertive Setup

<< Press ESC key to return to Main Menu or enter a command

5.4.1 SNCP/UPSR APS Command

Command Path: Unit Menu > (N) SNCP/UPSR APS Setup > (A) SNCP/UPSR APS Command How to Set up: Select the FOM port, E1 channel number, and Command. Then, press ENTER to save the new setting.
Unit 6 7FOM === SNCP/UPSR APS Command === ARROW KEYS: CURSOR MOVE, TAB/`: ROLL UP/DOWN OPTIONS Port : 1 Channel : 01 17:02:36 08/03/2011

Command : Clear

Note : FS MS PRI SEC

= = = =

Force Switch Manual Switch Primary Secondary

Card Model
7 FOM

Field
FOM Port E1 Channel Command

Setting Options
1 to 7 1 to 4 CLEAR, FS to PRI., FS to SEC., MS to PRI., MS to SEC., Lockout

32

CHAPTER 5 SYSETM SEUTP

5.4.2 SNCP/UPSR Revertive Setup

Command Path: Unit Menu > (N) SNCP/UPSR APS Setup > (B) SNCP/UPSR Revertive Setup How to Set up: Select the FOM port, E1 channel number, and Command. Then, press ENTER to save the new setting.
Unit 6 7FOM === SNCP/UPSR Revertive Setup === ARROW KEYS: CURSOR MOVE, TAB/`: ROLL UP/DOWN OPTIONS 17:03:15 08/03/2011

Port : 1 Channel : 01

Revertive: Non-Revertive

<< Press ESC key to return to previous menu >>

Card Model
7 FOM

Field
FOM Port E1 Channel Revertive

Setting Options
1 to 7 1 to 4 Revertive, Non-Revertive

33

CHAPTER 5 SYSETM SEUTP

5.5 Performance Setup/Clear

5.5.1 Clear Performance Data

Command Path: Unit Menu > (R) Performance Setup/Clear > (A) Clear Performance Data How to Set up: Press A from the Performance Setup/Clear menu. A prompt will appear as below. You can choose to clear performance of all ports, or individual port (port1~port7). After selection, press ENTER to confirm with your setting.
>> Use TAB key to select port, and ENTER key to clear performance: All Ports

5.5.2 Performance Threshold Setup

Command Path: Unit Menu > (R) Performance Setup/Clear > (B) Performance Threshold Setup Configuration: Field TCA Alarm Severity How to Set up: Disable or enable each monitor point, and select the severity level you need. Then, press ENTER to save the configuration.
Unit 1 7FOM === Performance Threshold Setup === ARROW KEYS: CURSOR MOVE, TAB/`: ROLL UP/DOWN OPTIONS Monitor Point ------------LP-BIP(V5) LP-REI(V5) LINE TCA Alarm --------DISABLE DISABLE DISABLE 17:10:25 06/23/2010

Setting Options Enable, Disable Inform, Major, Minor, Critical Disable Inform

Default

Severity Threshold(Block Error) -------- ---------------------INFORM 00600 INFORM 00600 INFORM 00200

<< Press ESC key to return to previous menu >>

34

CHAPTER 5 SYSETM SEUTP

5.6 Loopback & Diagnostics Setup


The O9400R-XCU16 7 FOM card is able to connect to remote devices such as O9500R, AM3440 or O9310 with a remote 7FOM card. The system supports FOM loopback and E1 loopback for self-testing.

FOM Loopback: The outgoing optical signal is looped back through the optical line. All its channels are looped back to the receiver path. This loopback test is activated by the test command.

E1 Loopback: The incoming E1 signal is loopback to the outgoing E1 signal, or vise versa. This loopback is used to isolate the local equipment from a troubled E1 signal. E1 loopback test can be activated from the terminal.

O9400R-XCU16

Remote Device: O9400R-XCU16, O9500R, AM3440, or O9310

7 4 5

7 FOM Card

7 FOM Card E1 Channel

E1 Channel

FOM Loopback:
1

Remote FOM Loopback:


3

LOC (Local Loopback) LLB (Line Loopback)

LLB (Line Loopback)

E1 Loopback:
4

Remote E1 Loopback:
6

To BP (Backplane) To FOM

To BP (Backplane) To FOM

Figure 5-1 7 FOM Loopback Diagram


35

CHAPTER 5 SYSETM SEUTP

5.6.1 FOM Loopback Setup

Command Path: Unit Menu > (G) Loopback & Diagnostics Setup > (A) FOM Loopback Setup Configuration: Field Port-1 ~ Port-7 How to Set up: Select the loopback type (LOC= local loopback, LLB= line loopback) for each port. Then, press ENTER to save the configuration.
Unit 2 7FOM === FOM Loopback Setup === ARROW KEYS: CURSOR MOVE, ENTER KEY: ITEM SELECT 15:44:29 06/29/2010

Setting Options OFF, LOC, LLB OFF

Default

PORT-1: PORT-2: PORT-3: PORT-4: PORT-5: PORT-6: PORT-7:

*OFF *OFF *OFF *OFF *OFF *OFF *OFF

LOC LOC LOC LOC LOC LOC LOC

LLB LLB LLB LLB LLB LLB LLB

<< Press ESC key to return to previous menu >>

36

CHAPTER 5 SYSETM SEUTP

5.6.2 FOM Remote Loopback Setup

Command Path: Unit Menu > (G) Loopback & Diagnostics Setup > (B) FOM Remote Loopback Setup Configuration: Field Port-1 ~ Port-7 How to Set up: Select the loopback type (LOC= local loopback, LLB= line loopback) for each port on the remote FOM card. Then, press ENTER to save the configuration.
Unit 2 7FOM === FOM Remote Loopback Setup === ARROW KEYS: CURSOR MOVE, ENTER KEY: ITEM SELECT 16:07:37 06/29/2010

Setting Options OFF, LLB OFF

Default

PORT-1: PORT-2: PORT-3: PORT-4: PORT-5: PORT-6: PORT-7:

*OFF *OFF *OFF *OFF *OFF *OFF *OFF

LLB LLB LLB LLB LLB LLB LLB

<< Press ESC key to return to previous menu >>

37

CHAPTER 5 SYSETM SEUTP

5.6.3 E1 Loopback Setup

Command Path: Unit Menu > (G) Loopback & Diagnostics Setup > (C) E1 Loopback Setup Configuration: Field Port-1 ~ Port-7: Channel 1~4 How to Set up: Select the loopback direction for E1 channel 1~4 of each port. Then, press ENTER to save the configuration.
Unit 2 7FOM === E1 Loopback Setup === ARROW KEYS: CURSOR MOVE, ENTER KEY: ITEM SELECT PORT-1 CHANNEL-1: CHANNEL-2: CHANNEL-3: CHANNEL-4: PORT-2 CHANNEL-1: CHANNEL-2: CHANNEL-3: CHANNEL-4: PORT-3 CHANNEL-1: CHANNEL-2: CHANNEL-3: CHANNEL-4: PORT-4 CHANNEL-1: CHANNEL-2: CHANNEL-3: CHANNEL-4: PORT-5 CHANNEL-1: CHANNEL-2: CHANNEL-3: CHANNEL-4: PORT-6 CHANNEL-1: CHANNEL-2: CHANNEL-3: CHANNEL-4: PORT-7 CHANNEL-1: CHANNEL-2: CHANNEL-3: CHANNEL-4: 10:42:40 07/29/2010

Setting Options OFF, TO BP, TO FOM OFF

Default

*OFF *OFF *OFF *OFF *OFF *OFF *OFF *OFF *OFF *OFF *OFF *OFF *OFF *OFF *OFF *OFF

To To To To To To To To To To To To To To To To

BP BP BP BP BP BP BP BP BP BP BP BP BP BP BP BP

To To To To To To To To To To To To To To To To

FOM FOM FOM FOM FOM FOM FOM FOM FOM FOM FOM FOM FOM FOM FOM FOM

*OFF *OFF *OFF *OFF *OFF *OFF *OFF *OFF *OFF *OFF *OFF *OFF

To To To To To To To To To To To To

BP BP BP BP BP BP BP BP BP BP BP BP

To To To To To To To To To To To To

FOM FOM FOM FOM FOM FOM FOM FOM FOM FOM FOM FOM

(To BP = To Backplane)

<< Press ESC key to return to previous menu >>

38

CHAPTER 5 SYSETM SEUTP

5.6.4 E1 Remote Loopback Setup

Command Path: Unit Menu > (G) Loopback & Diagnostics Setup > (D) E1 remote Loopback Setup Configuration: Field Port-1 ~ Port-7: Channel 1~4 How to Set up: Select the loopback direction for E1 channel 1~4 of each port at the remote site. Then, press ENTER to save the configuration.
Unit 2 7FOM === E1 Remote Loopback Setup === 10:43:28 07/29/2010 ARROW KEYS: CURSOR MOVE, ENTER KEY: ITEM SELECT PORT-1 PORT-5 CHANNEL-1: *OFF To BP To FOM CHANNEL-1: *OFF To BP To FOM CHANNEL-2: *OFF To BP To FOM CHANNEL-2: *OFF To BP To FOM CHANNEL-3: *OFF To BP To FOM CHANNEL-3: *OFF To BP To FOM CHANNEL-4: *OFF To BP To FOM CHANNEL-4: *OFF To BP To FOM PORT-2 PORT-6 CHANNEL-1: *OFF To BP To FOM CHANNEL-1: *OFF To BP To FOM CHANNEL-2: *OFF To BP To FOM CHANNEL-2: *OFF To BP To FOM CHANNEL-3: *OFF To BP To FOM CHANNEL-3: *OFF To BP To FOM CHANNEL-4: *OFF To BP To FOM CHANNEL-4: *OFF To BP To FOM PORT-3 PORT-7 CHANNEL-1: *OFF To BP To FOM CHANNEL-1: *OFF To BP To FOM CHANNEL-2: *OFF To BP To FOM CHANNEL-2: *OFF To BP To FOM CHANNEL-3: *OFF To BP To FOM CHANNEL-3: *OFF To BP To FOM CHANNEL-4: *OFF To BP To FOM CHANNEL-4: *OFF To BP To FOM PORT-4 CHANNEL-1: *OFF To BP To FOM (To BP = To Backplane) CHANNEL-2: *OFF To BP To FOM CHANNEL-3: *OFF To BP To FOM CHANNEL-4: *OFF To BP To FOM << Press ESC key to return to previous menu >>

Setting Options OFF, To BP, To FOM OFF

Default

39

CHAPTER 5 SYSETM SEUTP

5.6.5 E1 Diagnostics Setup

Command Path: Unit Menu > (G) Loopback & Diagnostics Setup > (E) E1 Diagnostics Setup Configuration: Field FOM Port E1 Channel Direction Test Pattern How to Set up: First, select the target FOM port and E1 channel number. Then, press ENTER.
Unit 2 7FOM === E1 Diagnostics Setup === 16:15:44 06/29/2010 ARROW KEYS: CURSOR MOVE, Please Input: 1~7, BACKSPACE to edit Send Test Pattern to ==> FOM Port : 1 E1 Channel : 1

Setting Options 1~7 1~4 FOM side, System Side 2^


15-1

Default 1 1 FOM side OFF

,2

^20-1

, OFF

Choose the direction and enable the test pattern. Then, press ENTER to save the configuration.
Unit 2 7FOM === E1 Diagnostics Setup === ARROW KEYS: CURSOR MOVE, TAB/`: ROLL UP/DOWN OPTIONS Send Test Pattern to ==> FOM Port : 1 E1 Channel : 1 Direction : FOM side Test Pattern: OFF 16:15:44 06/29/2010

<< Press ESC key to return to previous menu >>

40

CHAPTER 5 SYSETM SEUTP

5.7 FOM ALS/APSD Setup


Command Path: Unit Menu > (H) FOM ALS/APSD Setup Configuration: Field ALS Enable Pulse repetition time for automatic restart (sec) FOM P1~P7 Power Down FOM P1~P7 Manual Restart How to Set up: ALS EnableThe 7 FOM card supports ALS (Auto Laser Shutdown) function. When ALS enable is set as OFF, the laser function will remain active even if the optical line is disconnected (LOS alarm). ON, OFF Start, OFF OFF OFF Setting Options ON, OFF 60~300 OFF 300 Default

If you wish to disable the ALS function, select ON for ALS enable. The laser function will then shut (shuts/will shut) down when an optical line is disconnected. After the optical line is re-connected, the laser function will not restart automatically. To restart the laser function, you have to choose START for FOM port (P1~P7) manual restart. You can also key in the automatic restart time you wish in the Pulse repetition time for automatic restart section. Power DownIf you wish to disable the laser function for a particular FOM port with a connected optical line, select ON for FOM port (P1~P7) power down. The port will then stop sending Tx.
Unit 1 7FOM === FOM ALS/APSD Setup === ARROW KEYS: CURSOR MOVE, TAB/`: ROLL UP/DOWN OPTIONS ALS enable : OFF Pulse repetition time for automatic restart(sec) : 300 FOM FOM FOM FOM FOM FOM FOM FOM FOM FOM FOM FOM FOM FOM P1 P2 P3 P4 P5 P6 P7 P1 P2 P3 P4 P5 P6 P7 power power power power power power power down: down: down: down: down: down: down: OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF 19:16:44 06/23/2010

manual manual manual manual manual manual manual

restart: restart: restart: restart: restart: restart: restart:

<< Press ESC key to return to previous menu >>