Vous êtes sur la page 1sur 4

TARIQ MAHMOOD

Phone: +92-345-4493514, +92-311-4047227, E-mail: tariqmahmood.ee@gmail.com, tariqmahmood_ee@hotmail.com


Permanent Address: H # 25, Street # 128, Zaildar Road Ichra Lahore, Pakistan.
PROFILE: I have 6+ years of extensive Multi-Vendors experience in the Telecommunications Technology. I have Expertise with ZTE, NEC iPasolink, ALCATEL, NOKIA, SIEMENS and HUAWEI TXN/BTS Equipments. Hand on experience in Implementation & Troubleshooting of ZTE ZXSDR NEC iPasolink, Nokia Flexi Hopper, NOKIA Ultra BTS, NOKIA FLEXI EDGE BTS, NOKIA IBS Metro Sites, SIEMENS BS240XL-II BTS, NOKIA Flexi Hopper PDH Transmission, Siemens SralxD PDF/SDH Transmission, Huawei RTN600/620 PDH/SDH Transmission, Commissioning, Sweep Testing, BER Testing, Troubleshooting and Integration of MW Media from BSC. Good at organizational skills, time management and has the ability to handle multiple projects and deadlines.

Project Experience: Vendor Experience:


DURATION:
Sep-12 to Feb-13

Network Swap, Rollout, Expansions, Managed Services, Customer Support. NEC, ZTE, ALCATEL, NOKIA, SIEMENS, HUAWEI. DESIGNATION:
RAN Engineer (TL)

PROFESSIONAL EXPERIENCE PROJECT:


Telenor PK

COMPANY NAME:
ZTE Pakistan (Pvt) Ltd

TP VEGA PROJECT: Swap of BTS and MW Transmission. Supervision and Handling of sub-cons for BTS/MW Swap Activities. Implementation of New IP based BTS (ZTE SDR) & MW (NEC iPasso). Implementation of VLAN IP based Transmission system. Implementation of visibility of NEs on NMS Server. Connectivity of iPasso 1000/400/200 to ZTE PTN node. Implementation of iPasso (MW) E2E Connectivity. Implementation of new 3G Supporting ZTE SDR BTS. Commissioning of SDR BTS in different configurations using LMT. Swap of SDR BTS/NEC iPasso with different scenarios (Hard Swap, Cold Swap). Implementation of New ZTE OD/ID W301, T601 Power System. Responsible for all Pre-swap activities (Installation of RRU, Fiber, Jumper, Labeling). Responsible for all pre-swap external alarm verification from NOC. Responsible for Swap activity in outage window. Responsible for Support for Call Testing after Swap activities. Responsible for PAT with Quality Assurance.
DURATION:
Nov-11 to Sep-12

DESIGNATION:
Sr. Engineer (TL)

PROJECT:
O&M -Mobilink

COMPANY NAME:
Mobiserve Pakistan (Pvt) Ltd

Responsible for O&M of Telecom System & Power System on Mobilink Project, o Managing PM, CM, BSS, MW & ENV Activities in C-III for more than 700 Sites. o Responsible for daily BSS & Connectivity Activities to reduce TT Count. o Escalation of root causes to reduce the TT count and for better performance of Network. o Preparation of QOS Reports on daily bases. Supervision & Analyzing performance to BSS Team on daily bases. o Performing PM Audits and preparing the PM Audit Reports. Addressing daily Environmental CM Issues (Genset, AC, BSS and MW). o Preparing the daily outage Analysis Reports. o Coordination with field teams for technical support for better performance of Network. o Evaluation the performance of field engineers and encouraging the field teams. Maintaining the daily Hardware consumption record.

o o o o
DURATION:

Daily analysis for consumption of resources for cost saving. Guiding the field teams to reduce the consecutive visits for efficient utilization of resources. Special supervisions for NE, HUB and BSC sites. Responsible for power issues for all kinds.
DESIGNATION:
BSS/Transmission Team Lead

PROJECT:
Telenor PK

COMPANY NAME:
IKAN ENGINEERING SERVICES

Jun-08 to Nov-11

Responsibilities as BSS/Transmission Team Lead:


o o o
o

o o o o
o o o o o o o o o o o o o

Responsible for MW Loss surveys for NEC PHD links for Telenor roll out sites. Responsible for MW TXN links up gradations for Capacity increase. Responsible for the Achievements of Annual Targets, Quality Assurance. Responsible for all TI Activates in the Region, including Implementation, Commissioning, Alarm patching, Sweep Test, Troubleshooting to Partial Acceptance and Final Acceptance of a site. Responsible to carry out all the TI the Rollout activates in the region to meet monthly targets. Responsible to maintain the Quality of TI installation as described by the client (Telenor). Responsible for assigning the daily task to TI team. Responsible for making FAB forms for more than 200 sites.
Nokia Flexi Packet Networks & Flexi Hub MW Network Implementation & Troubleshooting. Nokia Flexi Hub configuration with Nokia Flexi Packet Hub. Commissioning & Configuration of Nokia Flexi Packet HW 1200 & 2200. Configuring the Flexi Packet 1200 & 2200 for 2G (E1) and 3G (Eth) interfaces. Configuring the MW Chain site without Flexi Packet First Mile. Performance and Monitoring of Flexi Packet Networks. Nokia Flexi Hopper 4/8/16xE1 IDU, ODU (1+0) configuration and commissioning. Nokia Flexi Hopper 4/8/16xE1 IDU, ODU (1+0) configuration and commissioning. Nokia Flexi Hopper FIU19E 16xE1 IDU, (1+1) ODU configuration and commissioning. Nokia E1/T1 Cross Connection configuration b/w different MW Links. Nokia Flexi Hopper FIU19E to RRI E1 Cross connection creation. Nokia BSC3i ET to PDH Cross Connection Creation & Hard Patching with HiT. Nokia Flexi Hopper FIU 19 connectivity with Huawei OSN-7500.

Technical Expertise with Nokia Flexi Hopper (MW Transmission):

Technical Expertise with Nokia Flexi EDGE BTS:


o o o o o o o o o o o o o o Nokia Flexi, Integration and Commissioning of Nokia Flexi Edge BTS. Nokia Flexi, Software Up gradation EP1,EP2,EP3 SWV 3.2-3 with Flexi EDGE BTS Manager V.3 MP2.0. Nokia Flexi, FCOA Modules (ESMA, DTRX, DDU, FIFA, FIPA) Configuration & Commissioning. Nokia Flexi, MW Transmission FIPA & FIFA Cards Configuration & Commissioning. Nokia Flexi, Abis Allocation for TCH, TRXSIG, EDAP and OMUSIGN using BTS Manager V3. Nokia Flexi, Call testing, TRX Loop testing, TRX Power measurement & Alarm Termination. Nokia Flexi, Fault rectification & Troubleshooting of BTS & MW link. Nokia Flexi, Simple Expansion & Complex Expansion with ESEA Card with Dual BTS Cabinets. Nokia Flexi, Performing Site Acceptance test Procedure after site is integrated Nokia Flexi, ECA (External Alarm Configuration) Installation & Commissioning. Nokia Flexi, Configuration of RJ48 Transmission port of FIPA with PDH E1 Interface. Nokia Flexi, Hopper Microwave Transmission Units Installation & Commissioning. Nokia Flexi, Responsible to provide the TI Support during the Drive Test of on Air BTS Site. Nokia Flexi, Troubleshoot the Hardware Software issues during the Soft Launch of BTS Site.

Technical Expertise with HUAWEI RTN600 (MW Transmission):


o o o o o o HUAWEI RTN610/620 IDU & ODU Installation and Commissioning. HUAWEI RTN610/620 Configuration using Optix iManager T2000 Web LCT. Configuration & Commission Optix RTN600 4/8/16xE1 and 1xSTM-1. Configuration of IDU Boards (PXC, SCC, IF1A, IF1B, IFX, PH1,PO1 SL1, SD1, EFT-4, EMS-6,etc). Implementation of Service Protection and Equipment Protection Schemes of the Optix RTN 600 Implementation of RTN620 with 1+1 Hot Stand By (HSB) protection

o o o o o o

Implementation of RTN620 with Microwave 1+1 Space Diversity (SD) protection Implementation of RTN620 with Cross-connect and clock unit (PXC) active/standby protection Configuring the HUAWEI IDU 610 16xE1 (1+0) Microwave Transmission Network. Configuring the HUAWEI IDU 620 16xE1 (1+1) Microwave Transmission Network. DCN Connectivity of HUAWEI RTN 600/620 IDUs. WM Transmission Nodes. E1 Line Cross Connection of HUAWEI RTN 610/620 MW Transmission Network.

Technical Expertise Transmission):


o o o o o o o

with

NEC

Pasolink

NEO

(MW

NEC: installation & Commissioning NEC PDH (5/10/16/20/32/40/48/2x40/2x48E1, 1/2E3). NEC: installation & Commissioning NEC SDH (STM-1, 2xSTM-1). NEC: Up gradation of Capacity of NEC 5E1 to 16E1 or 5E1 to 32E1 or 40E1 to 48E1 16E1 to 32E1 or 16E1 to 48E1 (interface card swap) 16E1 to STM-1 (interface card swap). NEC: SW Modulation Selection QPSK to 128 QAM. NEC: installation & Commissioning of X. Polarized XPIC STM Links. NEC: Implementation of VLAN & Gigabit Ethernet over STM Links. NEC: Implementation of NEC Hybrid & Adaptive modulation for SDH Link. DESIGNATION: BSS & TXN ENGINEER PROJECT: COMPANY NAME: MYSON

DURATION:

Aug-2006 to Jun 2008 ENGINEERING SYSTEMS o o o o o o o o o


o o o o o o o o o

Nokia/Siemens

Technical Expertise with Siemens SralxD (MW Transmission):


Siemens SralxD 4/8/16xE1 PDH (1+0) configuration and Commissioning. Siemens SralxD 16/32xE1 PDH (1+1) with HSB Protection Commissioning. Siemens SralxD up gradation 8xE1 using License update of Memory Key of IDU. Siemens SralxD up gradation 16/32xE1 with IDU Replacement and Traffic Shifting. Siemens SralxD MW Equipment Inventory generating & Physical Alarm Testing. Siemens SralxD Access the Far End Site remotely at Near End using NCT 7.0 & Net Builder. DCN Connectivity of MW Network Links for NMS access on Terminal. Testing the External and Environmental Alarm of NE and Alarm History Analysis. Siemens CBSC & EBSC Cross Connections Creation & PCMB Creation.
Nokia Ultra Site BTS Installation & Commissioning. Nokia Ultra Site BTS Commissioning with (222/222) single Cabinet. Nokia Ultra Site BTS Commissioning with (222/444,222/343, 222/424, etc) dual Cabinet. Nokia Ultra Site BTS Expansion (simple and complex) with single/dual Cabinet. Nokia Ultra Site BTS Abis Creation for (TCH, TRXSIG, EDAP, OMU). NOKIA E1 Sharing Complex Expansion Dual BTS and Abis Allocation. NOKIA Diversity Frame in Antenna Mount Expansion. NOKIA ET/HiT & NEC C-Node Patching & Cross Connection. NOKIA Soft Cross Connection using BTS HUB Manger. NOKIA ABIS Traffic Allocation with EDGE Implementation. NOKIA BTS Environmental Alarms Commissioning & Troubleshooting. NOKIA BTS Internal HW Alarms Troubleshooting. NOKIA Sweep Testing using BIRD and ANRITSU Site Master (900+1800 Bands). SIEMENS BS240XL EDGE BTS Installation and Commissioning. SIEMENS BS240XL Edge BTS Software up gradation BR80, BR90 and BR91 SIEMENS Simple & Complex Expansion with Single and Dual Cabinets. SIEMENS Commissioning the BS240xL with different configuration (222/222, 222/444, 222/666). SIEMENS BTS Environmental Alarms Commissioning & Troubleshooting. SIEMENS BTS Internal HW Alarms Troubleshooting with BS240xL Cabinet. SIEMENS BSC & EBSC to BTS Media Clearance for Cell Site Expansion. SIEMENS TYPE2 and TYPE4 BTS (BS240XL) Installation and Commissioning. SIEMENS EDGE Implementation and Call Testing.

Technical Expertise with Nokia Ultra Site (BTS):

o
o o o o o o o o o o o

Technical Expertise with Siemens BS240xL (BTS):

EDUCATION DURATION: 20022006 DEGREE BS (Elect Engr) UNIVERSITY University of Lahore GRADE A-

20002002 19982000 REFRENCES Available on demand

HSSC SSC

BISE-Faisalabad BISE-Faisalabad

A+ A+

Vous aimerez peut-être aussi