Académique Documents
Professionnel Documents
Culture Documents
: 1607-P1-b
ScenarioofsitesMechanicalWorks
Firefightingnetworkinstallations
Storagearea(B03)
1 Thecontractorwillaskedtheownerbeforestartinghisworkswith4daysto evacuatetheworkingareabetweentheracksandtheupperlevelofitin ordertobeabletowork 2 Thestorageareawillbedividedintothreepartsinthestoragearea. 3 Thecontractorwillstartinstallationofscaffoldingineachareafromthe groundtoupasshowninthe(fig1.)otherwiseovertheracksifaccepted.
Redarrows:Scaffolding Blackarrows:Labors&Materials
(Fig1)
GAMAForTrading&Contracting 1
Beity Plant Extension Project No.: 1607-P1-b 7 Paintingofthepipeswiththetwolayersofprimercoatwillbeoutsidethe site&thefinishlayerwillbeinsite. 8Thefabricationofpipesitswillbeinourworkshopyardoutsidetheworking areaasshowing(Fig4)
(Fig4) 9installationoffirefightingpipessupports(usingEquipmentDrillonlyand thereisnohotworks) 10Usingfixedscaffoldingabovetheracksortendenciesfloorsandmoving scaffoldingatflatfloorandcorridorstoInstallationofsupportsandpipes 11Transferpipeswithsmalldiameters(Lessthan2.5")byworkersmanually fromtheworkshoptotheplaceofinstallationandlargediameters(largerthan 2.5")transportitbyhandvehicletotheplacesofinstallation. 12Liftingpipeswithlargediametersfromthegroundtotheinstallationplaces byBlancoandliftingpipeswithsmalldiameterstotheplaceofinstallationby Handrollerspull 13Afterfinishingoftheinstallationworkandinstallationofpipesthenwater pressuretestforpipeswillbedone 14Afterthepressuretests,installationofsprinklers.
GAMAForTrading&Contracting 3
AirConditioninginstallations:
1 Stepsforinstallationoffans(rooftopfans)
1 Identifyingtheplacesofthefansaccordingtotheapproveddrawing 2Thecontractorwillstartinstallationofscaffoldingineachareafromthe Groundtoupasshowninthe(fig1.)otherwiseovertheracksifaccepted
GAMAForTrading&Contracting
GAMAForTrading&Contracting
Firefightingnetworkinstallations
Processingarea(B03groundfloor)
1 Thecontractorwillaskedtheownerbeforestartinghisworkswith4daysto evacuatetheworkingareabetweentheracksandtheupperlevelofitinorder tobeabletowork 2 Thecontractorwillstartinstallationofscaffoldingineachareafromthe groundtoupasshowninthe(fig1.)
Fig1
GAMAForTrading&Contracting 7
(Fig2) 4 Thelocationofpowersupplypanelforeclectictools(fig3.)
Fig3
GAMAForTrading&Contracting 8
(Fig4) 7Installationoffirefightingpipessupports(usingEquipmentDrillonlyandthere isnohotworks) 8UsingfixedscaffoldinginFlooringleaningandmovingscaffoldingatflatfloor andcorridorstoInstallationofsupportsandpipes 9InstallandfixcantileversupportsinColumnsofsteelstructureformainloops andthreadedrodsforbranchespipesbyfixeditinpearlinessthatinupperfloor passagethroughthesandwichpanel 10Transferpipeswithsmalldiameters(Lessthan2.5")byworkersmanuallyfrom theworkshoptotheplaceofinstallationandlargediameters(largerthan2.5") transportitbyhandvehicletotheplacesofinstallation. 11Liftingpipeswithlargediametersfromthegroundtotheinstallationplacesby BlancoandliftingpipeswithsmalldiameterstotheplaceofinstallationbyHand rollerspull 12Afterfinishingoftheinstallationworkandinstallationofpipesthenwater pressuretestforpipeswillbedone 13Afterthepressuretests,installationofsprinklers.
GAMAForTrading&Contracting 9
Firefightingnetworkinstallations
Juicepreparationarea(B02)
1 Thecontractorwillaskedtheownerbeforestartinghisworkswith48hours toevacuatetheworkingareabetweentheracksandtheupperlevelofitin ordertobeabletowork 2 Thecontractorwillstartinstallationofscaffoldinginetchareafromthe groundtoupasshowninthe(fig1.)Someareaswillbefixedscaffolding(above thetanksandM/C)andotherswillbemovingscaffolding
GAMAForTrading&Contracting
10
(Fig2) 4 Thereisnopathforpassageofcablestoworkinthisareaandtherefore sourceofelectricitywillbeusedfrominsidethebuilding,knowingthatthe toolsusedonlythedrillingM/C&thecuttingM/Cwillbeused 5 Thenumbersoflaborswhichwillworkatetchareaitwillbespecifiedindaily Report&willnotbelessthan45workers/eacharea 6 Paintingofthepipeswiththetwolayersofprimercoatwillbeoutsidethe Site&thefinishlayerwillbeonside. 7 Thefabricationofpipesitswillbeinourwork shopyardoutsidetheworkingareaasshowing(Fig
(Fig3) 8 installationoffirefightingpipessupports(usingEquipmentDrillonlyand thereisnohotworks) 9 Transferpipeswithsmalldiameters(Lessthan2.5")byworkersmanually fromtheworkshoptotheplaceofinstallationandlargediameters(larger than2.5")transportitbyhandvehicletotheplacesofinstallation. 10 Liftingpipeswithlargediametersfromthegroundtotheinstallationplaces byBlancoAndliftingpipeswithsmalldiameterstotheplaceofinstallationby Handrollerspull 11 Afterfinishingoftheinstallationworkandinstallationofpipesthenwater pressuretestforpipeswillbedone 12 Afterthepressuretests,installationofsprinklers.
GAMAForTrading&Contracting 11
AirConditioninginstallations:
Airhandlingunit'sinstallation&ductconnection
1Identifyingthelocutionoftheunitsaccordingtotheapproveddrawing 2Theaccesspassagetotheworkingareaisdescribedbelowasshownin (Fig1.)Showingtheentrance&theexitofthematerials
Proposed Scenario for work over the walk able ceiling areas
1Thefabricationofpipeswillbeinourworkshopyardoutsidetheworking Areaasshowing(Fig1)
(Fig1)
2Installationofsupportsforpipeswillbefixedbythreadedrodfromthebeamsandpurlins asshowingin(fig.2)
(Fig2)
GAMAForTrading&Contracting
13
4 Liftingpipesmanuallybylaborsviathestairsandputitinthearea(1)
GAMAForTrading&Contracting 14
6Totalnumbersofworkersinthewalkableceilingareawillbe7workersatthesametime.
GAMAForTrading&Contracting
15
Alternative Scenario for work over the walk able celling areas
After calculation of weights (workers & pipes) over the walk able ceiling it is found that we need another method of installation which is:
1Thefabricationofpipeswillbeinourworkshopyardoutsidetheworking Areaasshowing(Fig1)
GAMAForTrading&Contracting 16
4Makeopeninginthewallbetweenthewalkablesuspendedceilingandthebesideroom Area(1)asshowninthefollowingfigure.
6Totalnumbersofworkersinthewalkableceilingareawillbe4workersatthesame time.
GAMAForTrading&Contracting
18