Vous êtes sur la page 1sur 16

HEAD OFFICE

450 Gongdeok-dong, Mapo-gu, Seoul, KOREA


TEL. 82-2-707-6181 FAX. 82-2-707-6117
LOS ANGELES
Hyosung America, Inc. L.A. Branch
18000 Studebaker Road, Suite 550, Cerritos, Ca-90703, U.S.A.
TEL. 1-562-809-5050 FAX. 1-562-809-5251
TOKYO
Hyosung Japan, Co. Ltd.
SVAX TT Bldg, 11-15, 3-Chome, Toranomon, Minato-ku, Tokyo, 105 Japan
TEL. 81-3-3432-1005 FAX. 81-3-3459-9300

2004. 1

www.hyosung.com

Contents
General

Design

Electrical Properties

10

Technical data for LAP112-2

14

Technical data for LAP132-4

15

Technical data for LAP160-4

16

Technical data for LAR 180 and 200

17

Technical data for LAR 225 and 250

18

Technical data for LAB 355,400 and 450

19

Basic Dimensions for LAP

20

Basic Dimensions for LAR

22

Basic Dimensions for LAB

24

Flange Mounting

26

Additional dimensions for IC 06

27

Bearing load

28

Check list for choosing Motor

31

HYOSUNG DC Motor
Fast and accurate control when supplied from a

Good accessibility has been achieved by the modern,

converter, due to the low moment of inertia of the rotor and

square-section design and the provision of large inspection

the fully laminated stator construction.

panels.

A wide range of speeds is available, since commutation

Maximum versatility has been achieved by the wide range

problems have been eliminated and the rotors have high

of accessories, the many methods of installation and the

critical speeds.

closely-spaced ratings.

High overload capacity, due to the advanced rotor design

A high degree of environmental tolerance is assured by

and the modern insulation system, which is better than

a comprehensive range of cooling method and enclosures.

class F.

Tropicalized anti-corrosion treatment is standard.

Low vibrations and sound level have been achieved by


careful balancing of the rotor and by minimizing the
unbalanced magnetic forces. The end shields and stator
frames are machined in numerically controlled machine
tools.
1

General
Internal and external
environmental conditions

Type designation
The motors series has ten different centre heights.
For each centre height there are several types with lengths increasing by steps.
For each motor length there are a number of armature windings giving various base speeds with
the same voltage.

Example

??
?
?@@@he??
?@@@he?
?@@@he?
?@@@he?
?@@@he?
?@@@he?
?@@@he?
?@@@he?
?@@@he?
?@@@he?
?@@@he?
?@@@he?
?@@@he?
?@@@he?
?@@@he?
?@@@he?
?@@@@@@@@@@@e?
?@@@@@@@@@@@e??
??
??
?

@@@?h
?J@@@Lh
?7@@@1h
J@@@@@L?g
7@@?@@1?g
?J@@@?@@@Lg
?7@@5?3@@1g
?@@@H?N@@@g
J@@5e?3@@L?f
7@@He?N@@1?f
@@@?f@@@?f
?J@@@@@@@@@@@Lf
?7@@@@@@@@@@@1f
?@@@g?@@@f
J@@@g?@@@L?e
7@@5g?3@@1?e
@@@Hg?N@@@?e
@@@?h@@@?e

?@@@@@@@6Kg
?@@@@@@@@@6Xf
?@@@eI4@@@1f
?@@@fI'@@L?e
?@@@f?N@@1?e
?@@@g@@@?e
?@@@g@@@?e
?@@@f?J@@5?e
?@@@fO&@@H?e
?@@@eO2@@@5f
?@@@@@@@@@0Yf
?@@@@@@@0Mg
?@@@hf
?@@@hf
?@@@hf
?@@@hf
?@@@hf
?@@@hf

W2@@g
O2@@6Kg W2@@@@@@6Xf
O2@@6Kg
7@@@g W2@@@@@@6Xf
?J@@@@g
7@@@@@@@@)X?e?J@@@HeN@@@L?e
7@@(MI'@@1f
W&@@@@g
?J@@(MeI'@@1?e
&0Y@@@g
?7@@H?e?N@@@?e
?7@@@?e?@@@1?e
?@@@g
?@@@g@@@?e
?@@@5?e?3@@@?e
?@@@g?@@@W2@@@6X?f
?@@@hf?@@@g@@@?e
?@@@H?e?N@@@?e
?@@@g
?@@@g?@@@@(MI4@@1f
?@@@@@@@@@)Xf?@@@g@@@?e
?@@@g@@@?e
?@@@g
?@@@g
?@@@(Yf@@L?e
?@@@g@@@?e
?@@@g?@@@g@@@?e
?@@@H?f@@1?e?@@@L?e?J@@@?e
?@@@g@@@?e
?@@@g
?@@@g
?@@@g@@@?e
?@@@1?e?7@@@?e
?@@@g?N@@)KeO&@@H?e
?3@@L?e?J@@5?e?N@@@LeJ@@@H?e
?3@@@?e?@@@5?e
?@@@g
?@@@g
3@@)KO&@@5f
?@@@g 3@@@@@@@@5f
V4@@@@@@0Yf
I4@@0Mg V4@@@@@@0Yf
I4@@0Mg

?@@@@@@@@?e
?@@@@@@@@?e
?@@@@@@@@?e

W2@@f
?W&@@@f
?7@@@@f
J@@@@@f
7@@@@@f
?J@@?@@@f
?7@5?@@@f
J@@H?@@@f
7@5??@@@f
?J@@H??@@@f
W&@5e?@@@f
7@(Ye?@@@f
?J@@Y?e?@@@f
?7@@@@@@@@@@@@e
?@@@@@@@@@@@@@e
?@@@f
?@@@f
?@@@f

D.C Motor
Motor type(P/R/B)

Centre height in mm
LAP

LAR

LAB

112

180

355

poles
LAP

200

400

160

225

450

or

250

Motors can be installed in difficult environments, however the


correct method of cooling and degree of protection must be
chosen to ensure that the interior of the motor is as clean as
possible.
Proper machine alignment during installation are important to
ensure low machine vibration.
The motors are designed to be used with pure d.c. or 3 -phase
bridge convertors. They are nominally rated for ambient
temperatures of 40 at altitudes up to 1000 metres(3300 feet).
For ambient temperatures above or below 40C and altitudes,
over 1000 metres(3300 feet) the motor output can be obtained
from the adjacent diagram.

Corelength
LAP

LAR

LAR
LAB

LAB

132

??
?
?@@6X?he@@@???
?@@@1?h?J@@@??
?@@@@?h?7@@@??
?@@@@Lh?@@@@??
?@@@@1hJ@@@@??
?@@@@@L?g7@@@@??
?@@@@@1?g@@@@@??
?@@@?@@Lf?J@@@@@??
?@@@?@@1f?7@?@@@??
?@@@?3@@L?eJ@@?@@@??
?@@@?N@@1?e7@5?@@@??
?@@@e3@@L?J@@H?@@@??
?@@@eN@@1?7@5e@@@??
?@@@e?3@@?@@He@@@??
?@@@e?N@@@@5?e@@@??
?@@@f3@@@H?e@@@??
?@@@fN@@@f@@@??
?@@@f?@@@f@@@???
??
??
?

Ambient temperature/altitude
Output diagram

LB

LC

LD

Fan motor
The fan motor can be mounted above or on either side, at the drive end or at the non-drive end.
The location does not affect the output of the motor
It can be delivered with a slotted cover, a filter or a flange for an air-duct
On request a pressure relay can be installed on the fan motor.
The fan motor and terminal box can be arranged in 24 different mounting combinations

Standards
The motors comply with the requirements of the international standard IEC Publ. 34-1
Terminal markings
The terminal markings are in agreement with the recommendations in IEC Publ. 34-8
Mounting arrangenments
The motor is manufactured in accordance with IEC Publ. 34-7

IM 1011

IM 2011

IM 1001

IM 1002

IM 2001

(STANDARD)

(DOUBLE SHAFT)
Note : If no information is given with the order, the motor is delivered as shown in figure 21.

Degrees of protection and method of cooling


Degrees of protection

Method of cooling

The motor can be supplied with the following


degrees of protection in accordance with IEC 34-5.
For degrees of protection other than IP23S and IP54,
please contact Hyosung.

The Cooling forms comply with IEC Publ.34-6


The recommended method of cooling is
determined by the environment and the
location of the motor

DESIGN
Stator

Terminal box and terminals

The frame, main poles and interpoles consist of one stamping and
are fully laminated.This makes the stator assembly exceptionally
sturdy.
This method of construction eliminates the noise and vibrations
experienced when the main and auxiliary poles are mounted
within the frame and heat dissipation is significantly better.
This design improves the symmetry of repartition of flux. The
laminated frame allows a reduction of the time constant of the
lamination flux, and keeps it proportional to the armature current in
normal conditions, which gives good commutation to the motor.

A large cast iron terminal box is provided for ingoing


copper cables which are connected to an insulated
terminal board.
All cable connections are easily accessible.
The terminal box can be fitted on top or either side of the
motor.

Stator windings
The stator windings are of varnish insulated copper wire and are
impregnated after assembly.
The connections are crimped carefully to withstand overloads.

Armature
The armature core consists of discs of high class insulated
electro-plates, containing a large number of cooling ducts.
Low losses together with the effective cooling result in an efficent
motor with high output/weight ratio, without overstressing the
materials.
The armature has a high critical speed and is resistant in bending
to permit V-belt drive(see further under bearings ).

Brush gear
The brush gear is carefully engineered to give a rigid
assembly.
The brush holder tension springs are designed to give ;
*constant pressure
*mechanical stability indepenent of direction of rotation
*a high degree of reliability in contaminated surroundings.
These facotors have a positive influence on the
commutation.

Bearings
All motors are fitted with grease nipples and are designed
for greaing while the machine is in operation.
(except forms IC 0041, and IC 0641) The drive end is
furnished with ball or roller bearings depending on the
type of application. Independent greasing covers enable
inspection of the bearings.

Armature winding

Insulation system

The armature winding consists of enamel insulated copper wire


and is held in the slots by glass-fiber slot wedges or bandages.
The coils are connected to the commutator by brazing or by TIG
welding to withstand overloads.
The complete armature is dip-impregnated with polyester-varnish.

The copper used for stator and armature windings is


insulated with esterimide varnish and is of thermal class H.
The complete insulation of the motor complies with class
F(155 ), according to IEC 34-1, and permits a
temperature rise of 100 above an ambient temperature
of 40 , the insulation system is moisture resistant and
suitable for use in tropical climate without modification.

Temperature limits for different classes of insulation

155

15K
Normal Safety
margin(K=Kelvin)

10K

140
120
80K

100K

Permissible
temperature rise
(K=Kelvin)

End shields
The end shields are of cast iron. The motor feet are integrated in the end shield close to bearing and
they are accessible from the outside.
This result in a rigid and simple motor installation with low vibrations and high critical speed.
End shields and stator are bolted together by four heavy duty studs with a pre-determined torque.

40

Max. ambient temp.


at rated output

(B)
130

(F)
155

Class of
insulation

Seals are mounted between the stator and the end shields in order to keep the inside of the motor clean.
The square form of the stator and the end shieds permits simple installation of accessories and air ducts.

ELECTRICAL PROPERTIES
Definitions

Field control

Base speed = The rated motor speed at rated output, rated voltage, full excitation and normal
operating temperature.
Field weakening range = The ratio of the maximum electrical speed to the base speed.
Max. mech. speed = The speed to which the motor is limited by mechanical factors
Max. electr. speed = The highest speed which can be quoted for a given applcation without reduction
of armature current.

Excitation
Standard motors are delivered with separate excitation The standard voltages are 180 volts.
Other excitation voltages between 110V and 440V can be supplied on request.

Non- symmetrical current

A. Trimming
Motors can be quoted for trimmed base speed adjustment of the base speed by trimming should not exceed 25% of
the base speeds listed in the data sheets. The new speed is not to exceed the max. mechanical speed listed in this
catalogue.
B. Field control
The technical data lists a speed limits which can be quoted for motors with field regulation with full motor current and
overcurrent, n2,n3, and n4 are the limits for different types of motor application.
For speeds above these limits the motors must be operated with reduced current and overcurrent according to the
diagram below.
Note that the maximum operating speed must not be exceeded by means of field control.
n2 is the limit for pumps, fans extruders and propellers and other applications where the motor may run
continuously at the maximum speed.

Current ripple affects the commutating capability and the


motor losses. The motor data assumes that the maximum
asymmetry is 10%.

n3 is the limit for continuous steel mills, wire mills, hot and cold strip mills, all paper machine applications where the
motor may run at the maximum speed for a production run , but not continuously.
= Max. 10%

Overload currents

n4 is the limit for coilers, machine tool spindles,brake generators and other applications where the maximum speed
occurs for only a short time.

where

LAP LAR motors are designed for an overload current of


180% for 30sec. every 30 minutes.
Lower overloads can be applied for longer times.
For overloads above the max. electrical speed see under
Field Control. Overloads must be followed by periods
of low loads so that the motor current RMS value over a
load cycle is not greater than 100% rated current.

= non-symmetrical current
ripple from the converter
= rated motor current
time

Max. current as a function of speed


Permissisible load at maximum speed
Load current as % of rated current

Maximum Torque

180%

In accordance with IEC publ. 34-1 the motors can be loaded with 160% rated torque for 15 seconds every 5
minutes. the motors can give higher torques as shown in the diagram below.

Torque %

160%
Permissisible load at maximum speed
Load current as % of rated current

Torque %

160

200

200%

100%

140
150

120

150%

100
100
100%
50%
50

140

100
120

180

50

100

150

200
100%

160 Current %

200%

300%

Max speed in % av n2,n3, n4

LAB

LAP, LAR
Note : The tolerance for standard motors with shunt winding is

100

200

300

Current %

LAP, LAR

Max speed in % of n2,n3, n4

LAB

5%

10

Standstill current
Permissible load current when the machine is at a standstill with ventilating system in operation.
Load current in %
of the rated current

Time

180

10s

100

30s

50

90s

20

10 min

10

continuous

Current derivative
A rate of change of current of 200 times rated current per second and higher is permitted at all speeds below n2 and
with all loads.

Testing
Rountine test
The final quality control procedure during the manufacture of a motor is a routine test.
Each motor is subjected to such a routine test.

Part List

Test reports
A formal protocol of the routine test can be obtained upon request.
Type test
The type test is performed on the first machine of a series.
The result is then used as a reference for subsequent machines of the same type.
A type test must be requested with the order.
A formal test protocol of the type test will be sent to the customer.

Load Test
11

Field and Interpole Winding

Technical data for LAP 112-2M, 112-2L

Technical data for LAP 132-4S, 132-4M, 132-4L

with cooling forms IC 17, IC 37 and IC 06

with cooling forms IC 17, IC 37 and IC 06

Output and speed at 470V

Output and speed at 470V


kW

kW

22

50

20

45

18

40

16

35

14

132-4L

132-4M

30

112-2L

12

25

10

20

8
10

112-2M

2
500

1000 1500 2000 2500 3000

Common technical data

3500 4000

500

4500 5000 r/min

Units

LAP 112-2M

LAP 112-2L

Max.mechanical speed

r/min

5000

5000

Min.speed at constant torque

r/min

40

40

1000

Common technical data

1500

2000

Units

2500

3000

3500

4000 r/mn

LAP 132-4S LAP 132-4M LAP 132-4L

Max.mechanical speed

r/min

4000

4500

4000

Min.speed at constant torque

r/min

40

40

40

Moment of inertia

kgm2

0.03

0.04

Moment of inertia

kgm

0.10

0.12

0.14

Excitation power

420

500

Excitation power

750

830

1000

Maximum rated voltage

620

620

Maximum rated voltage

620

620

620

Excitation voltage(at rated voltage)

180/220/370

180/220/370

Excitation voltage(at rated voltage)

180/220/370

180/220/370

180/220/370

m /h

470

470

470

pa

550

550

550

Volume of cooling air


Internal air pressure drop(with IC 17, IC 37)

m3/h

235

235

Volume of cooling air

Pa

375

375

Internal air pressure drop(with IC 17, IC 37)


Weight(excl.accessories)

Weight(excl.accessories)
Foot mounting

kg

90

96

Foot mounting

kg

115

135

160

Flange mounting

kg

102

108

Flange mounting

kg

130

150

175

Conversion table
1kg=2.20lb
1kgm2=23.73lb.ft2
1kW=1.34HP

13

132-4S

15

1Nm=0.7375 lbf.ft
1m3/s=35.31 cu.ft/s

1m3/h=0.59 cu ft/min
1Pa=1N/m2=0.1mmH2O=1.45 10-4lbf/sq.in(PSI)
1atm=1.0 105Pa

Conversion table
1kg=2.20lb
1kgm2=23.73lb.ft2
1kW=1.34HP

1Nm=0.7375 lbf.ft
1m3/s=35.31 cu.ft/s

1m3/h=0.59 cu ft/min
1pa=1N/m2=0.1mmH2O=1.45 10-4lbf/sp.in(PSI)
1atm=1.0 105ap

14

Technical data for LAP 160-4S, 160-4M, 160-4L

Technical data for LAR 180 and 200

with cooling forms IC 17, IC 37 and IC 06

with cooling forms IC 17, IC 37, IC 06 and IC W 37A86

Output and speed at 470V

Output and speed at 470V


kW
kW

150
140
130

160-4L

65
60

160-4M

200LB
180LD

110
100

50
45

90

40

160-4S

30

180LC

80
70
60

35

25

50

20

40
30

15

180LB

20

10

10
500

Common technical data

1000

1500

2000

2500

3000

500

3500 r/min

1500

2000

2500

3000 3300 r/min

LAR
180LB

LAR
180LC

LAR
180LD

LAR
200LB

LAR
200LC

LAR
200LD

Max.mechanical speed

r/min

3300

3300

3300

3000

3000

3300

0.31

with IM 2101, IM 2111

r/min

3300

2900

2200

2400

2000

1600

1250

1400

Moment of inertia

kgm2

0.4

0.5

0.65

1.1

1.2

1.4

550

550

550

Excitation power

kW

1700

1800

1900

1700

1900

2100

180/220/370

180/220/370

180/220/370

Maximum rated voltage

620

620

620

620

620

620

m3/h

820

820

820

Excitation voltage

220

220

220

220

220

220

Pa

500

500

500

Volume of cooling air

m3/h

900

900

900

1120

1120

1120

Pa

950

950

950

1200

1200

1200

kg

335

385

445

525

565

640

LAP 160-4S

Max.mechanical speed

r/min

3500

3500

3500

Min.speed at constant torque

r/min

40

40

40

Moment of inertia

kgm2

0.22

0.25

Excitation power

1050

Maximum rated voltage

Excitation voltage(at rated voltage)

Internal air pressure drop(with IC 17, IC 37)

1000

Units

Units

Volume of cooling air

LAP 160-4M LAP 160-4L

Common technical data

Internal air pressure drop

Weight(excl.accessories)
Foot mounting

kg

190

220

265

(with IC 17, IC 37)

Flange mounting

kg

215

245

290

Weight(excl.accessories)

Conversion table

15

200LD

120

55

1kg=2.20lb
1kgm2=23.73lb.ft2
1kW=1.34HP

200LC

160

70

Conversion table
1Nm=0.7375 lbf.ft
1m3/s=35.31 cu.ft/s

1m3/h=0.59 cu ft/min
1Pa=1N/m2=0.1mmH2O=1.45 10-4lbf/sq.in(PSI)
1atm=1.0 105Pa

1kg=2.20lb
1kgm2=23.73lb.ft2
1kW=1.34HP

1Nm=0.7375 lbf.ft
1m3/s=35.31 cu.ft/s

1m3/h=0.59 cu ft/min
1Pa=1N/m2=0.1mmH2O=1.45 10-4lbf/sq.in(PSI)
1atm=1.0 105Pa

16

Technical data for LAR 225 and 250

Technical data for LAB 355, 400 and 450

with cooling forms IC 17, IC 37, IC 06 and IC W37A86

with cooling forms IC 17, IC 37, IC 06 and IC W37A86

Output and speed at 470V

Output and speed at 470V


KW

kW

250LC

450LC

600

450LD

350
550

250LD
300

225LD

250

450LB

500

250LB

450

225LC

400LC

200

400LB

400

225LB

150

355LC

350

355LA

355LB

300
100
250
50
200
500

Common
technical data

1000

1500

2000

2500

150

3000 r/min

500

1500

2000

2500 r/min

LAB LAB LAB LAB LAB LAB LAB LAB


355LA 355LB 355LC 400LB 400LC 450LB 450LC 450LD

Units

LAR
225LB

LAR
225LC

LAR
225LD

LAR
250LB

LAR
250LC

LAR
250LD

Max.mechanical speed

r/min

3000

3000

3000

2800

2800

2800

Max.mechanical speed

r/min

2400

2400

2400

2200

2200

2000

2000

1800

with IM 2101, IM 2111

r/min

2000

1800

1600

1600

1350

1300

Moment of inertia

kgm2

6.1

7.1

8.4

13.2

15.3

25.2

29.5

33.8

Moment of inertia

kgm2

2.0

2.2

2.5

3.7

4.1

4.6

Excitation power

kW

1.9

2.1

2.3

2.4

3.6

3.5

3.2

3.0

Excitation power

kW

2700

3000

3300

3000

3300

3600

Maximum rated voltage

815

815

815

815

815

815

815

815

Maximum rated voltage

620

620

620

620

620

620

Excitation voltage

180

180

180

180

180

180

180

180

Excitation voltage

220

220

220

220

220

220

Quantity of cooling air

m3/s

1.3

1.3

1.3

1.4

1.4

1.8

1.8

1.8

m3/s

0.5

0.5

0.5

0.6

0.6

0.6

Internal air pressure drop

Pa

1200

1200

1200

1100

1100

1200

1200

1200

Pa

1400

1400

1400

1500

1500

1500

kg

1660

1900

2180

2740

3070

3500

4010

4520

Volume of cooling air


Internal air pressure drop

Weight(excl.accessories)

kg

760

830

890

1040

Conversion table
1kg=2.20lb
1kgm2=23.73lb.ft2
1kW=1.34HP

1Nm=0.7375 lbf.ft
1m3/s=35.31 cu.ft/s

1m3/h=0.59 cu ft/min
1Pa=1N/m2=0.1mmH2O=1.45 10-4lbf/sq.in(PSI)

1140

1260

Units

(with IC 17, IC 37)


Weight(excl.accessories)

(with IC 17, IC 37)

17

Common
technical data

1000

Conversion table
1kg=2.20lb
1kgm2=23.73lb.ft2
1kW=1.34HP

1Nm=0.7375 lbf.ft
1m3/s=35.31 cu.ft/s

1m3/h=0.59 cu ft/min
1Pa=1N/m2=0.1mmH2O=1.45 10-4lbf/sq.in(PSI)
1atm=1.0 105Pa

1atm=1.0 105Pa

18

Basic Dimensions for LAP

Method of cooling IC17 and IC37


LAP

AA

AB

AC

AD

BA

BB

BC

CA

D*** DA***

112-2M

190

47.5

314

220

202

403

43

439

263

70

40.0

32k6

24k6

112-2L

190

47.5

314

220

202

458

43

494

318

70

40.0

32k6

24k6

132-4S

216

47.5

354

260

222

437

50

487

293

89

49.5

38K6

32K6

132-4M

216

47.5

354

260

222

482

50

532

338

89

49.5

38k6

32k6

132-4L

216

47.5

354

260

222

532

50

582

388

89

49.5

38k6

32k6

160-4S

254

56.0

441

316

252

475

56

531

342

108

56.0

48k6

38k6

1604M

254

56.0

441

316

252

522

56

578

389

108

56.0

48k6

38k6

160-4L

254

56.0

441

316

252

587

56

643

454

108

56.0

48k6

38k6

LAP

DE

DF

EA

F*

FA*

GA

GB

GC

H**

HA

HC

112-2M

M10

M10

80

50

10

27.0

35.0

20.0

27.0

112

10

252

112-2L

M10

M10

80

50

10

27.0

35.0

20.0

27.0

112

10

252

132-4S

M10

M10

80

80

10

10

33.0

41.0

27.0

35.0

132

12

272

132-4M

M10

M10

80

80

10

10

33.0

41.0

27.0

35.0

132

12

272

132-4L

M10

M10

80

80

10

10

33.0

41.0

27.0

35.0

132

12

272

160-4S

M16

M10

110

80

14

10

42.5

51.5

33.0

41.0

160

15

316

160-4M

M16

M10

110

80

14

10

42.5

51.5`

33.0

41.0

160

15

316

160-4L

M16

M10

110

80

14

10

42.5

51.5

33.0

41.0

160

15

316

LAP

HD

HK

JA

JB

LC

VG

VL

VN

VR

VT

VV

112-2M

236

54

110

110

12

591.0

643.0

105

75

100

125

125

233.0

112-2L

236

54

110

110

12

646.0

698.0

105

75

100

125

125

288.0

132-4S

276

74

150

125

12

653.5

753.5

145

65

110

140

165

255.5

132-4M

276

74

150

125

12

698.5

780.5

145

65

110

140

165

300.5

132-4L

276

74

150

125

12

748.5

830.5

145

65

110

140

165

350.5

160-4S

327

116

190

145

15

747.0

829.0

180

70

130

160

204

278.0

160-4M

327

116

190

145

15

794.0

876.0

180

70

130

160

204

325.0

160-4L

327

116

190

145

15

859.0

941.0

180

70

130

160

204

390.0

Remarks

19

*
**
***

F, FA

Tolerance

Tolerance

D, DA

Tolerance

ISO h9
0
-0.5
ISO m6

20

Basic Dimensions for LAR

21

Method of cooling IC17 and 37


LAR

AA

AB

AD

AX

BA

BB

BC

BJ

CA

D***

180LB
180LC
180LD

279
279
279

60
60
60

362
362
362

322
322
322

394
394
394

502
565
630

100
100
100

622
685
750

356
419
484

79
79
79

121
121
121

121
121
121

60
60
60

200LB
200LC
200LD

318
318
318

70
70
70

400
400
400

340
340
340

432
432
432

582
632
692

115
115
115

707
757
817

455
505
565

83
83
83

133
133
133

133
133
133

70
70
70

225LB
225LC
225LD

356
356
356

75
75
75

450
450
450

420
420
420

490
490
490

713
761
821

120
120
120

835
883
943

534
582
642

76
76
76

149
149
149

149
149
149

85
85
85

250LB
250LC
250LD

406
406
406

80
80
80

500
500
500

445
445
445

540
540
540

778
836
905

120
120
120

908
966
1035

607
665
734

80.5
80.5
80.5

167.5
167.5
167.5

168.5
168.5
168.5

95
95
95

LAR DA***

DE

DF

EA

F*

FA*

GA

GB

GC

H**

HA

180LB
180LC
180LD

55
55
55

M20
M20
M20

M20
M20
M20

140
140
140

110
110
110

18
18
18

16
16
16

53
53
53

64
64
64

49
49
49

59
59
59

180
180
180

16
16
16

200LB
200LC
200LD

60
60
60

M20
M20
M20

M20
M20
M20

140
140
140

140
140
140

20
20
20

18
18
18

62.5
62.5
62.5

74.5
74.5
74.5

53
53
53

64
64
64

200
200
200

18
18
18

225LB
225LC
225LD

70
70
70

M24
M24
M24

M24
M24
M24

170
170
170

140
140
140

22
22
22

20
20
20

76
76
76

90
90
90

62.5
62.5
62.5

74.5
74.5
74.5

225
225
225

22
22
22

250LB
250LC
250LD

85
85
85

M24
M24
M24

M24
M24
M24

170
170
170

170
170
170

25
25
25

22
22
22

86
86
86

100
100
100

76
76
76

90
90
90

250
250
250

25
25
25

LAR

HB

HC

HD

HK

JA

JB

JD

JE

JG

JH

UD

180LB
180LC
180LD

50
50
50

361
361
361

502
502
502

88
88
88

215
215
215

159
159
159

184
184
184

95
95
95

7
7
7

7
7
7

15
15
15

882
945
1010

82
82
82

200LB
200LC
200LD

62
62
62

402
402
402

540
540
540

120
120
120

235
235
235

175
175
175

175
175
175

95
95
95

7
7
7

10
10
10

19
19
19

986
1036
1096

82
82
82

225LB
225LC
225LD

62
62
62

450
450
450

645
645
645

64
64
64

274
274
274

209
209
209

209
209
209

127
127
127

14
14
14

19
19
19

19
19
19

1179
1227
1287

114
114
114

250LB
250LC
250LD

75
75
75

500
500
500

695
695
695

107
107
107

274
274
274

209
209
209

209
209
209

112.5
112.5
112.5

9.5
9.5
9.5

10
10
10

24
24
24

1281
1339
1408

114
114
114

LAR

VE

VF

VG

VK

VL

VN

VR

VS

VV

Remarks

180LB
180LC
180LD

231
231
231

195
195
195

200
200
200

135
135
135

47
47
47

170
170
170

200
200
200

175
175
175

343
406
471

200LB
200LC
200LD

251
251
251

205
205
205

220
220
220

155
155
155

62
62
62

160
160
160

191
191
191

191
191
191

419
469
529

*
**
***

225LB
225LC
225LD

290
290
290

235
235
235

255
255
255

180
180
180

69
69
69

180
180
180

225
225
225

225
225
225

518
566
626

250LB
250LC
250LD

290
290
290

255
255
255

255
255
255

190
190
190

64.5
64.5
64.5

190
190
190

225
225
225

225
225
225

581
639
708

F, FA

Tolerance

Tolerance

D, DA

Tolerance

ISO h9
0
-0.5
ISO m6

22

Basic Dimensions for LAB

Method of cooling IC17 and IC37


LAB

AA

AB

AC

AD

BA

BB

BC

CA

355LA
355LB
355LC

610
610
610

125
125
125

734
734
734

694
694
694

592
592
592

630
710
800

150
150
150

788
868
958

586
661
756

254
254
254

310
305
310

110
110
110

95
95
95

M24
M24
M24

M24
M24
M24

400LB
400LC

686
686

150
150

824
824

784
784

637
637

800
900

150
150

953
1053

771
871

280
280

306
306

125
125

110
110

M24
M24

M24
M24

450LB
450LC
450LD

750
750
750

150
150
150

924
924
924

884
884
884

687
687
687

800
900
1000

150
150
150

954
1054
1154

786
886
986

280
280
280

402
402
402

140
140
140

125
125
125

M30
M30
M30

M24
M24
M24

LAB

EA

F*

FA*

GA

GB

GC

H**

HA

HC

HD

HK

JA

JB

355LA
355LB
355LC

210
210
210

170
170
170

28
28
28

25
25
25

100
100
100

116
116
116

86
86
86

100
100
100

355
355
355

98
98
98

702
702
702

810
810
810

257
257
257

320
320
320

275
275
275

400LB
400LC

210
210

210
210

32
32

28
28

114
114

132
132

100
100

116
116

400
400

118
118

792
792

900
900

337
337

320
320

255
255

450LB
450LC
450LD

250
250
250

210
210
210

36
36
36

32
32
32

128
128
128

148
148
148

114
114
114

132
132
132

450
450
450

118
118
118

892
892
892

1000
1000
1000

437
437
437

320
320
320

336
336
336

LAB

JC

JD

JE

JG

JH

JK

JL

JM

JN

LC

VE

VF

VG

355LA
355LB
355LC

247
247
247

150
150
150

211
211
211

223
223
223

300
300
300

177
177
177

35
35
35

167
167
167

123
123
123

28
28
28

1401
1476
1571

1574
1649
1744

484
484
484

414
414
414

534
534
534

400LB
400LC

247
247

166
166

200
200

223
223

220
220

217
217

35
35

167
167

123
123

35
35

1593
1693

1806
1906

524
524

424
424

584
584

450LB
450LC
450LD

262
262
262

200
200
200

242
242
242

238
238
238

120
120
120

310
310
310

35
35
35

210
210
210

131
131
131

35
35
35

1729
1829
1929

1942
2042
2142

624
624
624

524
524
524

684
684
684

LAB

VH

VK

VL

VM

VN

VP

VR

VS

VT

VU

VV

355LA
355LB
355LC

385
385
385

187
187
187

46
46
46

400
475
570

285
285
285

245
245
245

365
365
365

267
267
267

674
674
674

444
444
444

500
575
670

400LB
400LC

365
365

187
187

45
45

560
660

265
265

245
245

345
345

267
267

674
674

422
422

660
760

450LB

446

202

60

560

346

260

425

282

760

506

660

450LC

446

202

60

660

346

260

425

282

760

506

760

450LD

446

202

60

760

346

260

425

282

760

506

860

*
**
***

F, FA

Tolerance

Tolerance

D, DA

Tolerance

Remarks

23

ISO h9
0
-1
ISO m6

D*** DA*** DE

DF

24

Additional dimensions for IC 06(cooling fan)

Flange mounting (IM 2101, IM 2111)

LAP

TYPE

LA

LAP 112-2

80

21

300

250j6

350

LAP 132-4

80

21

350

300j6

400

LAP 160-4

110

20

400

350j6

450

LAR

TYPE

25

LA

LAR 180

140

18

300

250j6

LAR 200

140

24

350

300j6

LAR 225

170

25

400

350j6

LAR 250

170

26

400

350j6

TYPE

CF

CX

DG

HF

HG

VA

LAP 112-2

321

107

154

457

133

220

LAP 132-4

339

107

154

505

153

254

LAP 160-4

357

107

180

616

183

315

LAR 180

456

125

199

824

272

356

LAR 200

471

125

199

885

287

395

LAR 225

476

125

244

933

312

395

LAR 250

501

125

244

983

337

395

LAB 355

544

225

244

1455

405

695

LAB 400

544

225

244

1545

450

695

LAB 450

602

225

284

175

540

764

26

Bearing load

LAP132

Motors for v-belt drive must be ordered with a roller bearing at


the d-end, instead of a ball bearing which is standard.
The minimum belt pulley diameter Dr(mm) can be obtained
from the formula:
Dr

2
F

2.5

103

Bearing no. 6309-C3

20,000h
Ball Bearing

Radial force(N)
F

200r/min
12000
11000

200r/min
500r/min
1000r/min

9000

3000r/min

LAP 112

20,000h
Ball Bearing

LAP 112

200 r/min

7000

200 r/min

7000

6000
2000 r/min

2000 r/min

3000 r/min

3000 r/min
5000
5000 r/min

5000 r/min
4000

3000
3000

2000

1000

20

27

40

60

80 X mm

8000

6000

5000

5000

4000

4000

3000

3000

2000

2000

1000

1000
40

60

Bearing no.6310-C3

80

X mm

20,000h
Ball Bearing

20

40

60

20

40

60

80

X mm

LAP160

Bearing no.NU310-C3

80

X mm

20,000h
Roller Bearing

Radial force(N)
F

Radial force(N)
F

200r/min
14000

14000
13000

200r/min

13000

12000

500r/min

12000

1000r/min

11000

1500r/min

11000

1000r/min

500r/min

10000

10000

3000r/min

2000r/min
3000r/min

8000

1000

3000r/min

7000

9000

4000

2000

9000

500 r/min
1000 r/min

1000 r/min

5000

2000r/min

6000

LAP160

500 r/min
6000

1000r/min

10000

20,000h
Roller Bearing

Bearing no.NU 307-C3

Radial force(N)

Radial force(N)

500r/min

11000

7000

20
Bearing no. 6307-C3

12000

2000r/min

8000

The permissible shaft loading is based on a bearing life of


20,000 hours.

20,000h
Roller Bearing

Bearing no. NU309-C3

Radial force(N)
F

10000

Dr = min. pulley diameter(mm)


2.5 = tensioning constant for V-belts
T = rated torque(Nm)
FR = radial force(N)
X = Dimension for load centre(mm)

LAP132

9000
8000

7000

7000

6000

6000

5000

5000

4000

4000

3000

3000

2000

2000

1000

1000
20

40

60

80

100 110 X mm

20

40

60

80

100 110 X mm

28

Check list for choosing motor

LAR180

20,000h

Bearing no. NU312-C3

LAR200

Bearing no. NU315-C3

20,000h

1. Driven object

:
: Direct coupled drive
: Axial force on moter shaft

Radial force(N)

Radial force(N)
F

: Radial force motor shaft

F
2200 r/min

14000
12000

3000 r/min

10000

22000
20000
18000

1500r/min

2. Environment

: Clean

Dirty

2200r/min

3. Service

: Motor

Generator

4. Motor duty

:T

3000r/min
8000

16000

6000

2000

40

LAR225

140

100

60

20

80

r/min

12000

at base speed

:P=

kW,

n=

r/min

10000

at min. speed

:P=

kW,

n=

r/min

at max.speed

:P=

kW,

n=

r/min

20

60

100

140

5. Type of operation

120

80

Bearing no. NU320-C3

LAR250

x mm

20,000h

continuous (S1)

Short time(S2)

min.

Intermittent(S3)

% load(10min. period)

6. Max. load in % of
Radial force(N)

Radial force(N)

30000

2200 r/min

1300 r/min

35000

2800 r/min
25000

15000

20000

10000

15000

5000

10000

75
50

125
100

170
150

x mm

7. Armature voltage

8. Excitation voltage

2000 r/min

30000

20000

% for sec

rated load

3000 r/min

20

Nm
n=

40

1500 r/min

Brake generator

kW,

x mm

20,000h

Gas

:P=

120

Bearing no. NU318-C3

Dripping water

torque

14000

4000

V-belt drive

9. Direction of rotation
(seen from D-end)

125

75

20
50

100

170

x mm

10. Ambient temperature

11. Height above sea level

12. Motor standards

:IEC 34

13. Convertor supply

: A.C. supply voltage:

m
Other
V, phase:

, Hz:

150

fully controlled

half controlled

other

29

30

Vous aimerez peut-être aussi