Vous êtes sur la page 1sur 66

Product Description

RAN11.0 BSC6810 V200R011

Issue

01

HUAWEI TECHNOLOGIES CO., LTD.

Huawei Technologies Co., Ltd. provides customers with comprehensive technical support and service. Please feel free to contact our local office or company headquarters.

Huawei Technologies Co., Ltd.


Address: Huawei Industrial Base Bantian, Longgang Shenzhen 518129 People's Republic of China Website: Email: http://www.huawei.com support@huawei.com

Copyright Huawei Technologies Co., Ltd. 2007. All rights reserved.


No part of this document may be reproduced or transmitted in any form or by any means without prior written consent of Huawei Technologies Co., Ltd.

Trademarks and Permissions


and other Huawei trademarks are trademarks of Huawei Technologies Co., Ltd. All other trademarks and trade names mentioned in this document are the property of their respective holders.

Notice
The information in this document is subject to change without notice. Every effort has been made in the preparation of this document to ensure accuracy of the contents, but all statements, information, and recommendations in this document do not constitute the warranty of any kind, express or implied.

Issue 01 (2008-03-29)

Commercial in Confidence

Page 2 of 66

About This Document


Author
Prepared by Reviewed by Approved by Gu lijie Date Date Date 2008-03-29

Summary
This document provides information for Huawei WCDMA Radio Network Controller (RNC). This document includes: Chapter 1 Introduction to the RNC 2 Key Benefits 3 System Architecture 4 Operation and Maintenance 5 Reliability 6 Technical Specifications 7 Installation Details Describes the position of the RNC in the WCDMA network. Describes the key benefits of the RNC. Describes the hardware structure, logical structure, and hardware configuration of the RNC. Describes the OM structure and OM functions of the RNC. Describes the system reliability, hardware reliability, and software reliability of the RNC. Describes the technical specifications of the RNC. Describes the hardware and software installation requirements for the RNC.

Issue 01 (2008-03-29)

Commercial in Confidence

Page 3 of 66

Revision Record
Issue Details Date Author Approved by

Issue 01 (2008-03-29)

Commercial in Confidence

Page 4 of 66

BSC6810 V200R010 Product Description

Contents
1 Introduction to the RNC................................................................................................. 8
1.1 About This Chapter...................................................................................................................... 8 1.2 Position of the RNC in the WCDMA Network................................................................................ 8 1.3 Main Functions of the RNC.......................................................................................................... 9

2 Key Benefits.................................................................................................................. 10
2.1 About This Chapter.................................................................................................................... 10 2.2 All-IP Platform of Advanced Radio Controller ............................................................................. 10 2.3 High Integration and Large Capacity.......................................................................................... 10 2.4 Flexible Configurations Adapting to Traffic Models ......................................................................11 2.5 Resource Sharing Between Control Plane and User Plane .........................................................11 2.6 Multiple Clock Sources ...............................................................................................................11 2.7 Diverse Transmission Solutions ................................................................................................. 12 2.7.1 Multiple Iub Network Topologies ........................................................................................ 12 2.7.2 Multiple Types of Transmission Port .................................................................................. 12 2.7.3 High Reliability of Transmission......................................................................................... 13 2.7.4 Flexible Configuration of Interface Boards ......................................................................... 13 2.7.5 IP Transport on the Iub/Iur/Iu Interfaces............................................................................. 13 2.7.6 Hybrid IP Transport on the Iub Interface ............................................................................ 13 2.7.7 ATM/IP Dual Stack on the Iub Interface.............................................................................. 13 2.7.8 Satellite Transmission on the Iub Interface ........................................................................ 14 2.7.9 Efficient Transmission on the Iub Interface ........................................................................ 14 2.7.10 Dynamic Management of the Bandwidth.......................................................................... 14 2.7.11 Inverse Multiplexing on ATM............................................................................................ 14 2.7.12 Fractional Functions........................................................................................................ 15 2.7.13 Timeslot Cross Connection.............................................................................................. 15 2.7.14 Multilink PPP................................................................................................................... 15 2.7.15 Ethernet Link Aggregation ............................................................................................... 15 2.8 Advanced RRM Algorithms ........................................................................................................ 15 2.8.1 Power Control ................................................................................................................... 15 2.8.2 Handover.......................................................................................................................... 16 2.8.3 Radio Resource Allocation ................................................................................................ 16 2.8.4 CAC and Load Control ...................................................................................................... 16 2.8.5 Service Differentiation Based on Subscriber Priorities ....................................................... 16

Issue 01 (2008-03-29)

Commercial in Confidence

Page 5 of 66

BSC6810 V200R010 Product Description 2.9 Advanced Network Sharing Solutions ........................................................................................ 16 2.9.1 RAN Sharing..................................................................................................................... 17 2.9.2 Lu Flex.............................................................................................................................. 17 2.9.3 MOCN .............................................................................................................................. 17 2.10 Advanced Solutions for Radio Data Services ........................................................................... 17 2.10.1 HSDPA ........................................................................................................................... 17 2.10.2 HSUPA ........................................................................................................................... 18 2.10.3 HSPA+............................................................................................................................ 18 2.10.4 MBMS............................................................................................................................. 18 2.11 High Compatibility of Protocols................................................................................................. 18

3 System Architecture .................................................................................................... 19


3.1 About This Chapter.................................................................................................................... 19 3.2 Physical Structure...................................................................................................................... 19 3.2.1 Cabinet Appearance.......................................................................................................... 19 3.2.2 Cabinet Components ........................................................................................................ 20 3.2.3 Subrack Components........................................................................................................ 22 3.2.4 RSS Subrack .................................................................................................................... 23 3.2.5 RBS Subrack .................................................................................................................... 26 3.3 Logical Structure........................................................................................................................ 27 3.3.1 Internal Switching Module ................................................................................................. 27 3.3.2 User Plane Data Processing Module ................................................................................. 27 3.3.3 Control Plane Data Processing Module ............................................................................. 28 3.3.4 Clock Module .................................................................................................................... 28 3.3.5 Transmission Interface Module.......................................................................................... 28 3.3.6 OM Module ....................................................................................................................... 28 3.4 Hardware Configuration............................................................................................................. 29 3.4.1 Minimum Configuration ..................................................................................................... 29 3.4.2 Maximum Configuration .................................................................................................... 29 3.4.3 Typical Configurations....................................................................................................... 30 3.4.4 Hardware Expansion Schemes ......................................................................................... 31

4 Operation and Maintenance ........................................................................................ 32


4.1 About This Chapter.................................................................................................................... 32 4.2 OM Structure............................................................................................................................. 32 4.3 OM Functions............................................................................................................................ 33 4.3.1 Security Management ....................................................................................................... 34 4.3.2 Configuration Management ............................................................................................... 34 4.3.3 Maintenance Management................................................................................................ 36 4.3.4 Fault Detection.................................................................................................................. 38 4.3.5 Performance Management ................................................................................................ 39 4.3.6 Alarm Management ........................................................................................................... 39 4.3.7 Loading Management ....................................................................................................... 40

Issue 01 (2008-03-29)

Commercial in Confidence

Page 6 of 66

BSC6810 V200R010 Product Description 4.3.8 Status Monitoring .............................................................................................................. 40 4.3.9 Message Tracing............................................................................................................... 41 4.3.10 Log Management ............................................................................................................ 42 4.3.11 Software Management .................................................................................................... 42

5 Reliability ...................................................................................................................... 44
5.1 About This Chapter.................................................................................................................... 44 5.2 System Reliability ...................................................................................................................... 44 5.3 Hardware Reliability................................................................................................................... 45 5.4 Software Reliability.................................................................................................................... 46

6 Technical Specifications.............................................................................................. 48
6.1 About This Chapter.................................................................................................................... 48 6.2 Performance Specifications ....................................................................................................... 48 6.3 Transmission Port Specifications ............................................................................................... 49 6.4 GPS Feeder Specifications........................................................................................................ 50 6.5 Reliability Specifications ............................................................................................................ 50 6.6 Structural Specifications............................................................................................................. 50 6.7 Electrical Specifications ............................................................................................................. 51 6.8 Power Consumption in Typical Configurations ........................................................................... 51 6.9 Clock Precision Specifications ................................................................................................... 52 6.10 Noise and Safety Compliance.................................................................................................. 52 6.11 Environmental Protection Specifications................................................................................... 53 6.12 International Protection Specifications...................................................................................... 53 6.13 Environmental Requirements................................................................................................... 53 6.13.1 Storage Environment....................................................................................................... 53 6.13.2 Transportation Environment ............................................................................................ 56 6.13.3 Working Environment ...................................................................................................... 58

7 Installation .................................................................................................................... 61
7.1 About This Chapter.................................................................................................................... 61 7.2 Hardware Installation................................................................................................................. 61 7.3 Software Installation .................................................................................................................. 62

A Acronyms and Abbreviations................................................................................... 63

Issue 01 (2008-03-29)

Commercial in Confidence

Page 7 of 66

BSC6810 V200R010 Product Description

1 Introduction to the RNC


1.1 About This Chapter
This chapter consists of the following sections:
l l

Position of the RNC in the WCDMA Network Main Functions of the RNC

1.2 Position of the RNC in the WCDMA Network


The RNC is an important element of the WCDMA network. RNCs and NodeBs compose the UMTS Terrestrial Radio Access Network (UTRAN). Figure 1-1 shows the position of the RNC in the WCDMA network. Figure 1-1 Position of the RNC in the WCDMA network
UE UTRAN Iu CN

Uu

RNC Iub

Iu-CS MSC server

NodeB Iub MGW Iu-PS NodeB

Iur

Iub

SGSN

NodeB

RNC Iu-BC CBC

Issue 01 (2008-03-29)

Commercial in Confidence

Page 8 of 66

BSC6810 V200R010 Product Description


CN: Core Network MGW: Media Gateway RNC: Radio Network Controller UE: User Equipment CBC: Cell Broadcast Center MSC server: Mobile Switching Center server SGSN: Serving GPRS Support Node UTRAN: UMTS Terrestrial Radio Access Network

As shown in Figure 1-1, each RNC can be connected to:


l l l l l

NodeBs through the lub interface The MSC (or the MSC server and MGW in R4/R5/R6/R7), which processes Circuit Switched (CS) services through the Iu-CS interface The SGSN, which processes Packet Switched (PS) services through the Iu-PS interface The CBC, which processes broadcast services through the Iu-BC interface Another RNC through the Iur interface

1.3 Main Functions of the RNC


The RNC has the following main functions:
l l l l l l

Broadcasting system information and controlling UE access Performing mobility management, such as handover and Serving Radio Network Subsystem (SRNS) relocation Performing radio resource management, such as Macro Diversity Combining (MDC), power control, and cell resource allocation Providing radio bearer services for both CS and PS domains Providing transport channels between the CN and UEs Ciphering and deciphering the signaling and data on radio channels

The model of Huawei RNC is BSC6810. Throughout the rest of this document, Huawei RNC is referred to as BSC6810. All its interfaces, including the Iub, Iur, Iu-CS, Iu-PS, and Iu-BC are standard interfaces, which enable the BSC6810 to connect to the NodeB, RNC, MSC, SGSN, and CBC of other vendors.

Issue 01 (2008-03-29)

Commercial in Confidence

Page 9 of 66

BSC6810 V200R010 Product Description

2 Key Benefits
2.1 About This Chapter
The design of the BSC6810 takes into consideration the factors such as services, capacity, transmission, and Operation and Maintenance (OM). The BSC6810 brings the following benefits:
l l l l l l l l l l

All-IP Platform of Advanced Radio Controller High Integration and Large Capacity Flexible Configurations Adapting to Traffic Models Resource Sharing Between Control Plane and User Plane Multiple Clock Sources Diverse Transmission Solutions Advanced RRM Algorithms Advanced Network Sharing Solutions Advanced Solutions for Radio Data Services High Compatibility of Protocols

2.2 All-IP Platform of Advanced Radio Controller


The BSC6810 uses the all-IP Platform of Advanced Radio Controller (PARC) developed by Huawei. PARC unifies the switching system of Asynchronous Transfer Mode (ATM), Time Division Multiplexing (TDM), and IP. Thus, it can serve as a uniform platform of GSM, CDMA, and WCDMA controllers. This platform can meet the requirements for the development of high-speed packet services and fully protect your network investment.

2.3 High Integration and Large Capacity


The BSC6810 has the following features:
l

The BSC6810 is highly integrated. Based on the Gigabit Ethernet (GE) star non-blocking switching on the Medium Access Control (MAC) sublayer, the BSC6810 achieves a central switching capacity of 120 Gbit/s. The BSC6810 supports up to 1,700 NodeBs and 5,100 cells.

Issue 01 (2008-03-29)

Commercial in Confidence

Page 10 of 66

BSC6810 V200R010 Product Description


l

The BSC6810 supports up to 60,000 Erlang traffic volume or a total of 3,840 Mbit/s PS throughput on the uplink (UL) plus downlink (DL). Such capacity, however, is implemented by only two cabinets. The BSC6810 provides a single-cabinet solution that supports 27,600 Erlang traffic volume or 1,766 Mbit/s (UL + DL) PS throughput. The BSC6810 provides a single-subrack (RSS) solution that supports 6,000 Erlang traffic volume or 384 Mbit/s (UL + DL) PS throughput.

l l

2.4 Flexible Configurations Adapting to Traffic Models


The number of signaling processing boards and that of data processing boards are flexible so that the quantity of resources on the user plane and control plane can meet the requirements of traffic models. In the case that a single set ratio of board configuration is inconsistent with the actual traffic model, the flexible configurations of boards in the BSC6810 help prevent wasting resources. The waste of control plane resources may attribute to the bottleneck at user plane resources, and the other way round.

2.5 Resource Sharing Between Control Plane and User Plane


In BSC6810, an SPUa board has four independent subsystems. Each subrack has a subsystem working as the Main Processing Unit (MPU) subsystem for the management of resources on the user plane and resource allocation during a call. The other subsystems work as Signaling Process Unit (SPU) subsystems, which process signaling messages on the Iu, Iur, Iub, and Uu interfaces to implement the signaling processing function. The SPU subsystems, working as the processor for control plane data, form a control plane resource pool; the DSPs, working as the processor for user plane data, form a user plane resource pool. The resources of control plane and user plane within a subrack are managed and allocated by the MPU subsystem. When a new call travels to the subrack, the MPU subsystem forwards the resources request to other subracks in case of overload. If any subrack has enough resources of control plane and user plane, the new call can be successfully processed.

2.6 Multiple Clock Sources


Multiple clock sources are available for the BSC6810. Thus, the BSC6810 can select system synchronization clocks conveniently. The available clock sources are as follows:
l l l

Building Integrated Timing Supply System (BITS) Global Positioning System (GPS) Line clock extracted from the Iu interface

Issue 01 (2008-03-29)

Commercial in Confidence

Page 11 of 66

BSC6810 V200R010 Product Description


l

External 8 kHz clock provided by an external device

The BSC6810 can set a priority for each clock source.

If the BSC6810 fails to obtain any external clock, the BSC6810 obtains its working timing signals from the local oscillator. The timing signals generated by the local oscillator, however, do not meet the requirements of NodeBs for the clock precision. Therefore, when the BSC6810 uses such timing signals, it is not recommended that the NodeBs obtain timing signals from the BSC6810.

2.7 Diverse Transmission Solutions


The BSC6810 provides diverse transmission solutions by supporting:
l l l l l l l l l l l l l l l

Multiple Iub Network Topologies Multiple Types of Transmission Port High Reliability of Transmission Flexible Configuration of Interface Boards IP Transport on the Iub/Iur/Iu Interfaces Hybrid IP Transport on the Iub Interface ATM/IP Dual Stack on the Iub Interface Satellite Transmission on the Iub Interface Efficient Transmission on the Iub Interface Dynamic Management of the Bandwidth Inverse Multiplexing on ATM Fractional Functions Timeslot Cross Connection Multilink PPP Ethernet Link Aggregation

2.7.1 Multiple Iub Network Topologies


The BSC6810 supports multiple Iub network topologies, such as star, chain, and tree topologies. The type of topology depends on the site requirement.

2.7.2 Multiple Types of Transmission Port


The BSC6810 provides multiple types of physical transmission port for the Iub, Iur, and Iu interfaces. The ATM transmission ports are of the following types:
l l l

E1/T1 Unchannelized STM-1/OC-3c Channelized STM-1/OC-3

The IP transmission ports are of the following types:


l

E1/T1

Issue 01 (2008-03-29)

Commercial in Confidence

Page 12 of 66

BSC6810 V200R010 Product Description


l l l l

Unchannelized STM-1/OC-3c Channelized STM-1/OC-3 Fast Ethernet (FE) GE

2.7.3 High Reliability of Transmission


To achieve high reliability of transmission, the BSC6810 uses the following solutions:
l

Transmission port redundancy


Unchannelized optical ports support Multiplex Section Protection (MSP) 1:1 or MSP 1+1 redundancy. Channelized optical ports support MSP 1:1 redundancy. FE or GE ports support redundancy and load sharing between the ports. Quick check based on Bi-directional Forwarding Detection (BFD) Address Resolution Protocol (ARP) check End-to-end ATM Continuous Check (CC) based on the F5 protocol

Diverse ways of fault detection:


2.7.4 Flexible Configuration of Interface Boards


The BSC6810 does not place restrictions on which slots hold interface boards for the Iub, Iur, or Iu. A subrack can host different types of ATM and IP interface board at the same time.

2.7.5 IP Transport on the Iub/Iur/Iu Interfaces


In addition to ATM transport, the BSC6810 supports IP transport on the Iub, Iur, and Iu interfaces. This is consistent with the evolution to an all-IP network, provides sufficient bandwidth for high-speed and large-volume data services, and reduces the cost of construction, operation, and maintenance of transport networks.

2.7.6 Hybrid IP Transport on the Iub Interface


When IP transport is applied to the Iub interface, data of different priorities can be transmitted separately through E1/T1 ports and FE/GE ports. The transmission mode of a service depends on the Quality of Service (QoS) requirement. Services with high QoS requirements are transmitted through E1/T1 ports, and those with low QoS requirements are transmitted on the Ethernet. Hybrid IP transport guarantees the QoS and provides sufficient interface bandwidth for high-speed PS services such as High Speed Downlink Packet Access (HSDPA) and High Speed Uplink Packet Access (HSUPA), thus saving the transmission cost and protecting the investment of operators.

2.7.7 ATM/IP Dual Stack on the Iub Interface


ATM/IP dual stack is supported between the BSC6810 and a NodeB. Services with high QoS requirements are transmitted through ATM, while those with low QoS requirements through IP.

Issue 01 (2008-03-29)

Commercial in Confidence

Page 13 of 66

BSC6810 V200R010 Product Description

Such data transmission guarantees the QoS and provides sufficient interface bandwidth for high-speed PS services such as HSDPA and HSUPA, thus saving the transmission cost and protecting the investment of operators.

2.7.8 Satellite Transmission on the Iub Interface


The BSC6810 supports satellite transmission on the Iub interface to cover isolated areas.

2.7.9 Efficient Transmission on the Iub Interface


The BSC6810 improves transmission efficiency by taking the following techniques on the Iub interface:
l

Iub overbooking and Frame Protocol Multiplexing (FP MUX) Without additional transmission devices, the BSC6810 improves the efficiency of transmission on the Iub interface, thus increasing the revenue of operators.

With Iub overbooking, the BSC6810 can estimate the bandwidth of a service on the Iub interface and allocate an appropriate bandwidth to the service. In this way, the Iub transmission efficiency increases greatly. With FP MUX, the BSC6810 can multiplex Iub FP data. That is, the BSC6810 multiplexes multiple User Datagram Protocol (UDP) or IP packets into one data packet in a specific format before transmitting it, thus increasing the efficiency of IP transport on the Iub interface.

IP shaping/policing Usually, the links on the NodeB side are low-speed ones. When a high-speed port on the BSC6810 connects to a low-speed port on a NodeB, packet loss may occur if the BSC6810 transmits packets to the NodeB. IP shaping/policing, however, can prevent such packet loss, balance traffic, and improve the efficiency of transmission on the Iub interface.

2.7.10 Dynamic Management of the Bandwidth


The BSC6810 detects the IP QoS information, such as the packet loss rate, delay, and delay variation. Based on the QoS, the BSC6810 then adjusts the bandwidth of logical ports and of resource groups. Thus, the transmission efficiency is enhanced.

2.7.11 Inverse Multiplexing on ATM


The BSC6810 provides the Inverse Multiplexing on ATM (IMA) function over E1/T1 links. An ATM cell stream from a high-speed transport link is multiplexed inversely onto multiple low-speed E1/T1 links. Then, at the receiver end, the low-speed cell streams are converged to the original high-speed cell stream. The IMA function enables high-speed transmission through low-speed links. Thus, it broadens the application scope of E1/T1 links. In addition, this function has a relatively high fault tolerance. Provided that the number of working links is not smaller than the specified minimum number of active links in an IMA group, services can continue. Thus, the IMA function ensures high transmission reliability.

Issue 01 (2008-03-29)

Commercial in Confidence

Page 14 of 66

BSC6810 V200R010 Product Description

2.7.12 Fractional Functions


The BSC6810 provides the fractional functions, that is, fractional ATM and fractional IMA. The fractional functions enable 3G equipment to share the E1/T1 links of a 2G network with 2G equipment, thus allowing 2G and 3G concurrent transmission. With the fractional functions, you can quickly deploy NodeBs at an early stage of WCDMA network construction by using the existing 2G transmission resources. Thus, you can launch the system at a comparatively low cost and within a relatively short period of time.

2.7.13 Timeslot Cross Connection


The BSC6810 supports the timeslot cross connection function. The 2G equipment cross-connects the timeslots on a 2G link to the BSC6810, so as to enable concurrent transmission of 2G and 3G data. Such timeslot cross connection does not require additional timeslot cross connection equipment.

2.7.14 Multilink PPP


The BSC6810 provides the Multilink PPP (MLPPP) function. This function combines physically independent links to form only one logical channel. Thus, the network layer can send data directly to this logical channel. The MLPPP function provides a relatively high bandwidth and implements rapid data forwarding.

2.7.15 Ethernet Link Aggregation


The BSC6810 provides the Ethernet link aggregation function. One or multiple Ethernet links are aggregated to form an Ethernet link aggregation group to provide services for the upper layer. This increases transmission bandwidth, optimizes load balance, and improves link reliability.

2.8 Advanced RRM Algorithms


The BSC6810 uses Huawei-patented Radio Resource Management (RRM) algorithms in the following functions:
l l l l l

Power control Handover Radio resource allocation Call Admission Control (CAC) Load control

In addition, the BSC6810 applies these algorithms in new features such as HSDPA, HSUPA, HSPA+, and Multimedia Broadcast and Multicast Service (MBMS). Thus, the BSC6810 offers optimum network coverage, capacity, and quality.

2.8.1 Power Control


The BSC6810 uses outer loop power control algorithms. It aims to provide the required quality for UEs when the radio environment changes and to increase the usage of system capacity.

Issue 01 (2008-03-29)

Commercial in Confidence

Page 15 of 66

BSC6810 V200R010 Product Description

2.8.2 Handover
The BSC6810 supports flexible handover strategies and parameter configurations. Based on different coverage areas, services and loads, it performs different kinds of handover, such as intra-frequency handover, inter-frequency handover, and inter-RAT handover. Thus, it improves the speech quality, reduces the call drop rate, and implements traffic absorption in special areas.

2.8.3 Radio Resource Allocation


Based on the QoS requirements, actual traffic volume, and actual cell load, the BSC6810 can allocate resources dynamically. Thus, it fulfills the communication requirements and increases the efficiency of radio channel resources.

2.8.4 CAC and Load Control


The BSC6810 applies multiple Huawei-patented technologies, such as load sharing and admission based on rate downsizing, to balance loads between cells and to control service access. Thus, it increases the system capacity and guarantees the current QoS.

2.8.5 Service Differentiation Based on Subscriber Priorities


Based on the allocation retention priorities set at the CN for subscribers, the BSC6810 can set the subscribers to three levels: gold, silver, and bronze. The BSC6810 then provides different services for the three levels of subscribers.
l

Based on priorities of subscribers, the BSC6810 sets different Guaranteed Bit Rates (GBRs) for Best Effort (BE) services of different subscribers. GBR guarantees that the basic requirements of BE services are met. With the pre-emption algorithm, high-priority subscribers can pre-empt the resources over low-priority subscribers. With the algorithm of rate downsizing against congestion, the BSC6810 preferentially downsizes the rates of low-priority subscribers to their GBRs. With the scheduling algorithm, the BSC6810 proportionally allocates bandwidths to subscribers. This algorithm takes subscriber priorities into account in the condition that the GBRs of the subscribers are guaranteed. With the flow control algorithm, the BSC6810 proportionally allocates bandwidths to subscribers. This algorithm takes subscriber priorities into account in the condition that the GBRs of the subscribers are guaranteed.

l l l

When radio resources are limited, the BSC6810 can guarantee GBRs of subscribers before allocating the remaining resources proportionally.

2.9 Advanced Network Sharing Solutions


The BSC6810 adopts the advanced RAN sharing, lu Flex, and MOCN functions to meet the requirements for shared networks among multiple telecom operators.

Issue 01 (2008-03-29)

Commercial in Confidence

Page 16 of 66

BSC6810 V200R010 Product Description

2.9.1 RAN Sharing


The BSC6810 supports the RAN sharing function. Through the RAN sharing function, carriers can be exclusively used by one telecom operator, and RAN devices can be shared by multiple telecom operators. Therefore, the operation costs are reduced and the device usage is enhanced.

2.9.2 lu Flex
The BSC6800 supports the Iu Flex function. One RNC can be connected to multiple CS CN nodes and PS CN nodes that belong to one telecom operator. The CS CN nodes and PS CN nodes connected to one RNC form a resource pool. Based on their capacities, the CN nodes in the pool share the load.

2.9.3 MOCN
The BSC6800 supports the multiple operator core network (MOCN) function. The RNC can be connected to the core networks of different telecom operators, thus enhancing the network sharing function. MOCN enhances the performance of the WCDMA network in the following aspects:
l l

Carriers can be shared by multiple telecom operators, thus reducing the operation costs and improving resource usage. The following types of NodeB can coexist: MOCN-capable NodeB, NodeB supporting RAN sharing, and dedicated NodeB. This meets the telecom operators' requirements for flexible networking. Telecom operators can select the optional features to diversify the configurations. Telecom operators can measure the performance at the RNC level or on the Iu interface, thus enabling them to maintain network devices independently.

l l

For one RNC, the RAN sharing function and the MOCN function cannot be enabled simultaneously.

2.10 Advanced Solutions for Radio Data Services


The BSC6810 adopts the advanced technologies, such as HSDPA, HSUPA, HSPA+, and MBMS, to meet the requirements of different types of data service.

2.10.1 HSDPA
The BSC6810 adopts HSDPA as the solution for high-speed DL data transmission. The DL rate for a single UE can reach up to 14.4 Mbit/s on the physical layer. In addition, the BSC6810 supports VoIP over HSDPA and IMS over HSDPA, where VoIP stands for Voice over IP and IMS stands for IP Multimedia Subsystem. HSDPA enhances the performance of the WCDMA network in the following aspects:
l l

Higher DL data rate Shorter service delay and more pleasant user experience in high-speed services

Issue 01 (2008-03-29)

Commercial in Confidence

Page 17 of 66

BSC6810 V200R010 Product Description


l

More efficient DL coding and power utilization

2.10.2 HSUPA
The BSC6810 adopts HSUPA as the solution for high-speed UL data transmission. The UL rate for a single UE can reach up to 5.76 Mbit/s on the physical layer. In addition, the BSC6810 supports VoIP over HSUPA and IMS over HSUPA. HSUPA enhances the performance of the WCDMA network in the following aspects:
l l l l

Higher UL data rate Shorter service delay and more pleasant user experience in high-speed services Faster UL resource control Better quality of service

2.10.3 HSPA+
The BSC6810 adopts the advanced HSPA+ technology. Based on HSUPA and HSDPA, HSPA+ further improves the network performance and expands the network capacity. HSPA+ has the following features:
l

HSPA+ supports higher DL peak data rate for a single UE. If the 64QAM modulation scheme is used, the DL peak data rate for a single UE can reach 21.6 Mbit/s on the MAC sublayer. If the multi-input multi-output (MIMO) technology is used, the DL peak data rate for a single UE can reach 28.8 Mbit/s. HSPA+ supports more VoIP subscribers. In the CELL_FACH state, HSPA+ supports higher throughput.

l l

HSPA+ enhances the performance of the WCDMA network in the following aspects:
l l l

Higher DL data rate More efficient spectrum usage Better QoS

2.10.4 MBMS
The BSC6810 adopts MBMS to provide the high-speed multimedia broadcast service. The transmission rate of MBMS services can reach up to 256 kbit/s. MBMS enhances resource efficiency and provides diversified multimedia services.

2.11 High Compatibility of Protocols


The BSC6810 is developed according to 3GPP R7 specifications. It is compatible with other Network Elements (NEs) and UEs based on 3GPP R7, R6, R5, R4, or R99 specifications.

Issue 01 (2008-03-29)

Commercial in Confidence

Page 18 of 66

BSC6810 V200R010 Product Description

3 System Architecture
3.1 About This Chapter
This chapter consists of the following sections:
l l l

Physical Structure Logical Structure Hardware Configuration

3.2 Physical Structure


3.2.1 Cabinet Appearance
The BSC6810 uses the standard N68E-22 or N68-21-N cabinet of Huawei. The design complies with the IEC60297 and IEEE standards.

Issue 01 (2008-03-29)

Commercial in Confidence

Page 19 of 66

BSC6810 V200R010 Product Description

Figure 3-1 shows the cabinet. Figure 3-1 BSC6810 cabinet

3.2.2 Cabinet Components


The BSC6810 has the following two types of cabinet:
l l

RNC Switching Rack (RSR) RNC Business Rack (RBR)

Issue 01 (2008-03-29)

Commercial in Confidence

Page 20 of 66

BSC6810 V200R010 Product Description

Figure 3-2 shows the components of the cabinets. Figure 3-2 Components of the BSC6810 cabinets

Power distribution box


R I N T R I N T R I N T R I N T R R I I N N T T R I N T R I N T R I N T R I N T R I N T R I N T R I N T R I N T R I N T R I N T R I N T

Power distribution box


R I N T R R I I N N T T R I N T R I N T R I N T R I N T R I N T R I N T R I N T R I N T

RBS
S P U a S P U a S P U a S P U a S P U a S P U a S C U a S C U a D P U b D P U b D P U b D P U b D P U b D P U b S P U a S P U a S P U a S P U a S P U a S P U a S C U a S C U a D D P P U U b b D P U b D P U b D P U b D P U b

RBS

R I N T

R I N T

R I N T

R I N T

R R I I N N T T

R I N T

R I N T

R I N T

R I N T

R I N T

R I N T

R I N T

R I N T

R I N T

R I N T

R I N T

R I N T

R R I I N N T T

R I N T

R I N T

R I N T

R I N T

R I N T

R I N T

R I N T

R I N T

RBS
S P U a S P U a S P U a S P U a S P U a S P U a S C U a S C U a D P U b D P U b D P U b D P U b D P U b D P U b S P U a S P U a S P U a S P U a S P U a S P U a S C U a S C U a D D P P U U b b D P U b D P U b D P U b D P U b

RBS

R I N T

R I N T

R I N T

R I N T

R R I I N N T T

O M U a

O M U a

R I N T

R I N T

R I N T

R I N T

R I N T

R I N T

R I N T

R I N T

R R I I N N T T

R I N T

R I N T

R I N T

R I N T

R I N T

R I N T

R I N T

R I N T

RSS
S P U a S P U a S P U a S P U a S P U a S P U a S C U a S C U a D P U b D P U b D P U b D P U b G C U a G C U a S P U a S P U a S P U a S P U a S P U a S P U a S C U a S C U a D D P P U U b b D P U b D P U b D P U b D P U b

RBS

RSR

RBR

The RINT refers to the interface board of the BSC6810. Physically, there is no board named RINT.

Issue 01 (2008-03-29)

Commercial in Confidence

Page 21 of 66

BSC6810 V200R010 Product Description

RSR
The RSR provides the single-cabinet solution. The RSR has the following components:
l l

One RNC Switching Subrack (RSS) Zero to two RNC Business Subracks (RBSs)

RBR
The RBR is configured when the required service processing capability exceeds the specifications for the RSR. At most one RBR can be configured. The RBR is configured with only RBSs. The number of RBSs in the RBR ranges from 1 to 3. If the RBR is configured with one or two RBSs, the RBSs should be configured from the bottom to the top.

3.2.3 Subrack Components


The BSC6810 has two types of subrack, according to board configuration. They are the RSS and the RBS. The BSC6810 can be configured with up to six subracks. Among the subracks, one is the RSS, and the others are RBSs. The number of RBSs ranges from 0 to 5. The subracks of the BSC6810 have a standard width of 19 inches, which complies with the IEC60297 standard. The height of a single subrack is 12 U. In a subrack, the backplane is positioned in the middle, and front and rear boards are installed on both sides of the backplane, as shown in Figure 3-3. The slots are of the same length. Figure 3-3 Subrack of the BSC6810
14 C 20 27

A 0 6 13

A: front boards

B: backplane

C: rear boards

Each subrack of the BSC6810 provides a total of 28 slots. The 14 slots on the front side of the backplane are numbered from 0 to 13, and those on the rear side from 14 to 27.

Issue 01 (2008-03-29)

Commercial in Confidence

Page 22 of 66

BSC6810 V200R010 Product Description

On each plane from leftmost to rightmost, every two even- and odd-numbered neighboring slots have an active/standby relationship. For example, slots 0 and 1 are active/standby slots. The same is true for slots 2 and 3. Only the boards that work in active/standby mode must be installed in active/standby slots.

3.2.4 RSS Subrack


The mandatory RSS is configured at the bottom of the RSR. The RSS is the central switching subrack of the BSC6810. This subrack has the following functions:
l l l l l

Connecting to each RBS and transferring data between RBSs through data switching on the MAC sublayer Providing system timing signals Providing the same service processing functions as the RBS Serving physical transmission on the Iub, Iur, and Iu interfaces Performing OM management of the Back Administration Module (BAM)

The RSS can provide a single-subrack solution. Figure 3-4 shows the boards in the RSS. Figure 3-4 Boards in the RSS
14 R I N T S P U a 0 15 R I N T S P U a 1 16 R I N T S P U a 2 17 R I N T S P U a 3 18 R I N T S P U a 4 19 R I N T S P U a 5 S C U a 6 20 O M U a S C U a 7 D P U b 8 21 22 O M U a D P U b 9 23 24 R I N T D P U b 10 25 R I N T D P U b 11 26 R I N T G C U a 12 27 R I N T G C U a 13

0 presents only an example of board configuration. You can change the configuration as required.

The RSS provides 28 slots. Table 3-1 describes the boards in the RNC cabinet.

Issue 01 (2008-03-29)

Commercial in Confidence

Page 23 of 66

BSC6810 V200R010 Product Description

Table 3-1 Boards in the RNC cabinet Board Full Spelling Function Configuration

DPUb

RNC Data Processing Unit REV:b

Processing and distributing service data The following slots are on the user plane available for the DPUb:
l

Slots 811 and 1419 in the RSS Slots 819 in an RBS

l l

GCUa

RNC General Clock Unit REV:a

Generating the system clock, and performing phase-lock and hold on the Two boards are permanently configured system clock in slots 12 and 13 of the Generating RNC Frame Number RSS. (RFN) signals for the system

Having all the functions of the GCUa; in Two boards are addition, receiving and processing GPS permanently configured signals in slots 12 and 13 of the RSS. GCGa RNC General Clock with GPS Card REV:a Only one type of clock board is configured in the RNC. In other words, the GCGa board and the GCUa board cannot be configured in the RNC at the same time.
l

OMUa

RNC Operation and Maintenance Unit REV:a

Performing configuration management, performance management, fault management, security management, loading management, and so on Working as the OM agent of the M2000 and Local Maintenance Terminals (LMTs) to provide the BSC6810 OM interface for the M2000 and LMTs and to control communication between the BSC6810 and the M2000/LMTs

One board is permanently configured in slots 20 and 21 of the RSS, and the other in slots 22 and 23.

SCUa

RNC GE Switching and Control Unit REV:a

l l l

Providing MAC switching, and enabling convergence of ATM and IP networks Providing 60 Gbit/s switching capacity Two boards are Providing the port trunking function permanently configured Enabling inter-subrack connections in slots 6 and 7. Providing configuration and maintenance of a subrack or of the whole BSC6810 Distributing timing signals and RFN signals for the BSC6810

Issue 01 (2008-03-29)

Commercial in Confidence

Page 24 of 66

BSC6810 V200R010 Product Description

Board

Full Spelling

Function
l

Configuration

SPUa

RNC Signaling Processing Unit REV:a

l l l l

Processing high-layer signaling of the Uu, Iu, Iur, and Iub interfaces Processing transport layer signaling The following slots are available for the SPUa: Allocating and managing various resources necessary to service l Slots 05 and 811 in setup, and establishing signaling and the RSS service connections l Slots 05 and 811 in Providing 4 independent processor an RBS systems Processing RFN signals Providing 32 E1s/T1s Providing ATM over E1/T1 Providing 32 IMA groups or 32 UNI links (Each IMA group contains a maximum of 32 IMA links.) The following slots are Providing the fractional ATM and available for the AEUa: fractional IMA functions l Slots 1419 and Providing the timeslot cross 2427 in the RSS connection function l Slots 1427 in an Providing ATM Adaptation Layer 2 RBS (AAL2) switching Extracting the clock from E1/T1 links, exporting 2 MHz signals, and sending the 2 MHz timing signals to the GCUa/GCGa Providing 2 STM-1/OC-3 optical ports Providing 126 E1s or 168 T1s Providing ATM over E1/T1 over SDH The following slots are Providing the IMA and UNI functions available for the AOUa: Providing 84 IMA groups, each of l Slots 1419 and which contains 32 E1s/T1s 2427 in the RSS Providing AAL2 switching l Slots 1427 in an Receiving timing signals from RBS upper-level equipment and sending them to the GCUa/GCGa Providing timing signals for NodeBs Providing 4 STM-1/OC-3c optical ports Providing ATM over SDH or IP over SDH Receiving timing signals from upper-level equipment and sending them to the GCUa/GCGa Providing timing signals for NodeBs The following slots are available for the UOIa:
l

RNC 32-port ATM over E1/T1/J1 RINT AEUa Interface Unit REV:a

l l l

RNC 2-port ATM over Channelized Optical AOUa STM-1/OC-3 Interface Unit REV:a

l l

l l

l l

UOIa

RNC 4-port ATM/Packet over Unchannelized Optical STM-1/OC-3c Interface Unit REV:a

Slots 1419 and 2427 in the RSS Slots 1427 in an RBS

Issue 01 (2008-03-29)

Commercial in Confidence

Page 25 of 66

BSC6810 V200R010 Product Description

Board

Full Spelling

Function
l l

Configuration

RNC 32-port Packet over E1/T1/J1 PEUa Interface Unit REV:a

l l

Providing 32 E1s/T1s Providing IP over PPP/MLPPP over E1/T1 Providing 128 Point-to-Point Protocol The following slots are (PPP) links or 64 MLPPP groups available for the PEUa: (Each MLPPP group contains a l Slots 1419 and maximum of 8 MLPPP links.) 2427 in the RSS Providing the timeslot cross l Slots 1427 in an connection function RBS Receiving timing signals from upper-level equipment and sending them to the GCUa/GCGa Providing timing signals for NodeBs Providing 2 STM-1/OC-3 optical ports The following slots are Providing 126 E1s or 168 T1s available for the POUa: Providing IP over E1/T1 over SDH l Slots 1419 and Receiving timing signals from 2427 in the RSS upper-level equipment and sending l Slots 1427 in an them to the GCUa/GCGa RBS Providing timing signals for NodeBs Providing 8 FE ports or 2 GE electrical ports Providing IP over FE or IP over GE The following slots are available for the FG2a:
l

RNC 2-port IP over Channelized Optical POUa STM-1/OC-3 Interface Unit REV:a

l l l

l l

RNC Packet over Electrical 8-port FE FG2a or 2-port GE Ethernet Interface Unit REV:a

Slots 1419 and 2427 in the RSS Slots 1427 in an RBS

RNC 2-port Packet over Optical GE GOUa Ethernet Interface Unit REV:a

Providing 2 GE optical ports Providing IP over GE

The following slots are available for the GOUa:


l

Slots 1419 and 2427 in the RSS Slots 1427 in an RBS

The RSS can be configured with one or two OMUa boards. In the latter case, the two boards work in active/standby mode.

3.2.5 RBS Subrack


The optional RBS is configured in the RSR or the RBR. The RBS is the basic service processing subrack of the BSC6810. Working as the extension subrack of the RSS, the RBS is used to extend the service processing capability of the BSC6810. This subrack has the following functions:
l l l

Processing signaling on the control plane Processing and distributing service data on the user plane Serving physical transmission on the Iub, Iur, and Iu interfaces

Issue 01 (2008-03-29)

Commercial in Confidence

Page 26 of 66

BSC6810 V200R010 Product Description

Figure 3-5 shows the boards in the RBS. Figure 3-5 Boards in the RBS
14 R I N T S P U a 0 15 R I N T S P U a 1 16 R I N T S P U a 2 17 R I N T S P U a 3 18 R I N T S P U a 4 19 R I N T S P U a 5 20 R I N T S C U a 6 21 R I N T S C U a 7 22 R I N T D P U b 8 23 R I N T D P U b 9 24 R I N T D P U b 10 25 R I N T D P U b 11 26 R I N T D P U b 12 27 R I N T D P U b 13

Figure 3-5 presents only an example of board configuration. You can change the configuration as required.

The RBS provides 28 slots. The RBS holds all types of board in the RSS except the GCUa/GCGa and OMUa.

3.3 Logical Structure


The BSC6810 consists of the following functional modules:
l l l l l l

Internal Switching Module User Plane Data Processing Module Control Plane Data Processing Module Clock Module Transmission Interface Module OM Module

3.3.1 Internal Switching Module


The internal switching module is mainly implemented by the SCUa boards. The SCUa in the RSS performs first-level switching and that in the RBS performs second-level switching. Thus, the BSC6810 provides internal MAC switching at two levels. The two-level switching enables full connection between all modules of the BSC6810.

3.3.2 User Plane Data Processing Module


The user plane data processing module is mainly implemented by the DPUb boards. This module performs protocol processing at each layer on the user plane data for the RNC.

Issue 01 (2008-03-29)

Commercial in Confidence

Page 27 of 66

BSC6810 V200R010 Product Description

The DPUb boards perform the following protocol:


l l l l l l l

Frame Protocol (FP) MDC MAC RLC PDCP Iu User Plane (Iu UP) protocols GTP-U

3.3.3 Control Plane Data Processing Module


The control plane data processing module is mainly implemented by the SPUa boards. This module processes control plane signaling on each interface for the RNC. The processed messages are of the following types:
l l l l l

Radio Access Network Application Part (RANAP) NodeB Application Part (NBAP) Radio Network Subsystem Application Part (RNSAP) Radio Resource Control (RRC) Service Area Broadcast Protocol (SABP)

The SPUa boards are configured in both the RSS and RBSs.

3.3.4 Clock Module


The clock module is mainly implemented by the GCUa/GCGa boards and the clock processing units of other boards. This module provides the clock for the operation of the RNC, generates RFN signals, and provides NodeBs with timing signals. The GCUa/GCGa boards are configured only in the RSS. If the RNC requires GPS signals, the GCGa is required.

3.3.5 Transmission Interface Module


The transmission interface module is mainly implemented by the AEUa, AOUa, UOIa, PEUa, POUa, FG2a, or GOUa boards. This module provides the transmission interface between the BSC6810 and other NEs. In addition, it performs related protocol processing at the transport network layer. For ATM transport, the AAL2 and ATM Adaptation Layer 5 (AAL5) messages are terminated at the transmission interface module. For IP transport, this module processes UDP and IP messages on the user plane and forwards IP messages on the control plane.

3.3.6 OM Module
The OM module is mainly implemented by the LMT, BAM, and related modules of host boards. This module performs operation and maintenance on the BSC6810.

Issue 01 (2008-03-29)

Commercial in Confidence

Page 28 of 66

BSC6810 V200R010 Product Description

3.4 Hardware Configuration


3.4.1 Minimum Configuration
In minimum configuration, the BSC6810 needs only one RSR that has only the RSS. The minimum configuration applies to an early stage of construction of a commercial network. Figure 3-6 shows the minimum configuration of the BSC6810. Figure 3-6 Minimum configuration of the BSC6810

Empty

Empty

RSS

Cabinet 1

The maximum capacity of the BSC6810 in minimum configuration is as follows:


l l l

6,000 Erlang traffic volume or 384 Mbit/s (UL + DL) PS throughput 200 NodeBs 600 cells

3.4.2 Maximum Configuration


In maximum configuration, the BSC6810 needs two cabinets, that is, one RSR and one RBR. You can add RBSs to expand the system capacity without disrupting ongoing services. Figure 3-7 shows the maximum configuration of the BSC6810.

Issue 01 (2008-03-29)

Commercial in Confidence

Page 29 of 66

BSC6810 V200R010 Product Description

Figure 3-7 Maximum configuration of the BSC6810

RBS

RBS

RBS

RBS

RSS

RBS

Cabinet 1

Cabinet 2

The maximum capacity of the BSC6810 in maximum configuration is as follows:


l l l

60,000 Erlang traffic volume or 3,840 Mbit/s (UL + DL) PS throughput 1,700 NodeBs 5,100 cells

3.4.3 Typical Configurations


Table 3-2 shows the typical configurations of the BSC6810. You can choose a typical configuration as required. Table 3-2 Typical configurations of the BSC6810 Number of Subracks 1 RSS 1 RSS + 1 RBS 1 RSS + 2 RBSs 1 RSS + 3 RBSs 1 RSS + 4 RBSs 1 RSS + 5 RBSs BHCA Traffic Volume (Erlang) 250k 600k 950k 1300k 1,650k 2,000k 6,000 16,800 27,600 38,400 49,200 60,000 (UL + DL) PS Throughput (Mbit/s) 384 1075 1,766 2,458 3,149 3,840 Number of NodeBs 200 500 800 1,100 1,400 1,700 Number of Cells 600 1,500 2,400 3,300 4,200 5,100

Note: BHCA: Busy Hour Call Attempt

For the BSC6810, both the BHCA value and the traffic volume are calculated on the basis of Huawei traffic model.

Issue 01 (2008-03-29)

Commercial in Confidence

Page 30 of 66

BSC6810 V200R010 Product Description

3.4.4 Hardware Expansion Schemes


You can expand the capacity of the BSC6810 by adding RBSs or service processing boards. The addition of SPUa boards contributes to the expansion of control plane resources, and the addition of DPUb boards contributes to the expansion of user plane resources. When adding boards, note the following items:
l

In the RSS, SPUa boards can be configured in slots 05 and 811. The maximum number of SPUa boards in the RSS is 10. In an RBS, SPUa boards can be configured in slots 05 and 811. The maximum number of SPUa boards in an RBS is 10. In the RSS, DPUb boards can be configured in slots 811 and 1419. The maximum number of DPUb boards in the RSS is 10. In an RBS, DPUb boards can be configured in slots 819. The maximum number of DPUb boards in an RBS is 12.

Table 3-3 lists the processing capabilities of SPUa and DPUb boards. The processing capability of the SPUa can be calculated on the basis of the capability of each SPU subsystem. Table 3-3 Processing capability of a single SPU subsystem or DPUb board Board or BHCA Subsystem SPU subsystem DPUb 25,000 Traffic Volume (Erlang) 1,800 (UL + DL) PS Throughput (Mbit/s) 120

Issue 01 (2008-03-29)

Commercial in Confidence

Page 31 of 66

BSC6810 V200R010 Product Description

4 Operation and Maintenance


4.1 About This Chapter
This chapter consists of the following sections:
l l

OM Structure OM Functions

4.2 OM Structure
Figure 4-1 shows the OM system of the BSC6810. The system consists of the Front Administration Module (FAM), BAM, OM terminals and alarm box. These components are described as follows:
l l

The FAM consists of the boards in the RSS and RBSs. It is the OM object entity. The physical entity of the BAM is the OMUa boards in the RSS. The BAM collects and processes OM information and sends the information to LMTs and the iManager M2000. The LMTs are OM terminals on the BSC6810 side. The iManager M2000 is a centralized OM system. The alarm box provides audible and visible alarms.

l l

Issue 01 (2008-03-29)

Commercial in Confidence

Page 32 of 66

BSC6810 V200R010 Product Description

Figure 4-1 OM system of the BSC6810

BAM: Back Administration Module LMT: Local Maintenance Terminal VLAN: Virtual Local Area Network

FAM: Front Administration Module IP: Internet Protocol

The LMT is the OM terminal on the NE side. It can access the BAM through Virtual Local Area Network (VLAN), an intranet, and the Internet. The LMT is an intelligent Man Machine Language (MML) client working in Graphic User Interface (GUI) mode. It provides the BSC6810 with OM functions. Through an external alarm box, the LMT can report audible and visible alarms if faults are detected.

4.3 OM Functions
The BSC6810 provides MML commands and GUIs as an interface for system management, configuration, maintenance, alarm management, and so on. Such an interface is explicit and easy to use. In addition, the BSC6810 can check the data integrity for an MML command to be run. This section describes the following OM functions:
l l l

Security Management Configuration Management Maintenance Management

Issue 01 (2008-03-29)

Commercial in Confidence

Page 33 of 66

BSC6810 V200R010 Product Description


l l l l l l l l

Fault Detection Performance Management Alarm Management Loading Management Status Monitoring Message Tracing Log Management Software Management

4.3.1 Security Management


BSC6810 security management provides the following functions:
l

Grade-based operator right setting You can set the operator right, operation time limit, and password to ensure system security and operation flexibility.

Operator information protection If no operation is performed for a certain period, the user interface is automatically locked.

File Transfer Protocol (FTP) transmission based on ciphering This ensures the security of FTP transmission. Encryption of the communication interface between the BSC6810 and the Element Management System (EMS) The BSC6810 uses the Security Socket Layer (SSL) protocol to fulfill transmission of ciphertext over the OM channel between the BSC6810 and the EMS. This ensures data security.

4.3.2 Configuration Management


The BSC6810 provides certain functions for configuration management. These functions are described in the following topics.

Automatic Data Configuration


The BSC6810 can automatically generate the configuration data that is necessary for internal physical and logical connections and configure the data for the corresponding parts. No manual configuration is required. You need to configure only the data for connections between the BSC6810 and external devices, thus improving the serviceability of the BSC6810.

Online and Offline Data Configuration


The BSC6810 supports the following configuration modes:
l

Offline data configuration In offline data configuration mode, configuration data is stored only in the BAM. The data is not sent to the host before being loaded onto the host. Therefore, this mode increases the efficiency of configuring a large amount of data. The BSC6810 also supports offline data configuration based on host subracks. Therefore, it allows capacity expansion without disrupting services.

Issue 01 (2008-03-29)

Commercial in Confidence

Page 34 of 66

BSC6810 V200R010 Product Description


l

Online data configuration In online data configuration mode, configuration data is sent to the host immediately after the configuration. There is no need to reset the BSC6810 or to reload the data. Thus, dynamic data configuration is enabled.

Dynamic Batch Data Configuration


The BSC6810 supports dynamic configuration of data in batches. With this function, the batch data configuration scripts are executed when the BSC6810 is offline. After the BSC6810 switches to the online mode, the BAM sends all the configuration data to the host in batches. The data takes effect with no need to restart or reset the subracks or boards. This avoids disrupting ongoing services. In the case of bulk data modification, such as NodeB reparent and change of interface board types, dynamic batch data configuration improves efficiency.

Data Configuration Right Control


Under data configuration right control, only one user has the right to perform data configuration for the BSC6810 at any time. The configuration is allowed on only one configuration console at a time, that is, either on the LMT or on the M2000. With the control, data configuration on the LMT and that on the M2000 are not allowed at the same time, thus improving reliability of the BSC6810.

Binary Interface Right Control


The BSC6810 supports binary-interface right control. On the LMT or M2000, user authority management and operation authentication can be performed on the binary interface, thus improving the security of the binary interface.

Data Configuration Rollback


The BSC6810 provides the data configuration rollback function. If data configuration fails to achieve the expectation or even causes equipment or network exceptions, you can perform rollback to restore the configurations quickly. This ensures proper running of the BSC6810.

Data Backup
When two OMUa boards are configured, they work in active/standby mode. The data on the standby OMUa is synchronized with that on the active OMUa. The BSC6810 supports automatic and manual data backup. It provides a data backup and recovery tool.

Data Validity Check


The BSC6810 can check the integrity and consistency of configuration data, such as the data of a cell.

Configuration Data Query


The BSC6810 supports the object-based query of configuration data.

Issue 01 (2008-03-29)

Commercial in Confidence

Page 35 of 66

BSC6810 V200R010 Product Description

Online Reconfiguration of the RINT and Backup Mode


The BSC6810 supports online reconfiguration of the RINT and of the board and port redundancy mode, thus facilitating reconfiguration of services.

Dynamic Assignment of IP Addresses to a NodeB


When ATM transport is applied to the Iub interface, the BSC6810 uses the Bootstrap Protocol (BOOTP) to automatically assign the OM IP address to a NodeB. When IP transport is applied to the Iub interface, the BSC6810 uses the Dynamic Host Configuration Protocol (DHCP) to automatically assign the OM IP address to the NodeB. Compared with BOOTP, DHCP has relatively powerful functions. In addition, DHCP is compatible with BOOTP.

Network Parameter Setting


The radio network parameters of the BSC6810 are of two types: RNC-oriented and cell-oriented. They can adapt to different radio environments.

4.3.3 Maintenance Management


The BSC6810 provides certain functions for maintenance management. These functions are described in the following topics.

Board Maintenance
The BSC6810 supports the following board maintenance functions:
l l l l l l l l

Resets on different levels, including equipment reset, subrack reset, board reset, and subsystem reset Query of board reset causes Hot swap Setting of boards to the out-of-service state for troubleshooting Query of board status and version information Board self-detection and board diagnosis test Query of the Central Processing Unit (CPU) usage of a board subsystem Forced active/standby board switchover initiated on the LMT

Object Status Query


The BSC6810 supports the query of the status of certain objects, the reasons for status changes, and the time when the status changes. The objects are as follows:
l l l l

Equipment objects, such as boards, subsystems, Digital Signal Processors (DSPs), clocks, optical ports, and BAM Physical transmission resource objects, such as E1/T1 links, IMA links, and UNI links IP transport links, such as PPP links and MLPPP links Logical transmission resource objects, such as Signaling ATM Adaptation Layer (SAAL) links, Stream Control Transmission Protocol (SCTP) links, Message

Issue 01 (2008-03-29)

Commercial in Confidence

Page 36 of 66

BSC6810 V200R010 Product Description

Transfer Part level 3 - broadband (MTP3-b) links, AAL2 paths, IP paths, NodeB Control Ports (NCPs), and Communication Control Ports (CCPs)
l

Radio resource objects, such as cells and channels

Panel Emulation
The emulated panel on the LMT interface can display the status of boards, Light Emitting Diodes (LEDs) on boards, external physical ports, and DSPs.

Physical Link Maintenance


The BSC6810 supports the status query and loopback test of physical links.

Logical Link Maintenance


The BSC6810 supports the following logical link maintenance functions:
l l l l l l l l

Status query, activation, and deactivation of Signaling System No. 7 (SS7) signaling links Status query of SAAL links and SCTP links Query about the status of IP traffic channels, and dynamic adjustment of the IP bandwidth Status query, blocking, unblocking, and reset of AAL2 traffic channels Status query and reset of PPP links, MLPPP links, and MLPPP groups Status query of IMA groups, UNI links, and IMA links Loopback test ATM F5 end-to-end detection

SS7 Signaling Point Maintenance


The BSC6810 supports maintenance of SS7 signaling points. The maintenance includes query, inhibit and uninhibit of destination signaling points.

Measurement of Out-of-Service NodeBs or Cells


If a NodeB or cell is out of service, it is unavailable. The BSC6810 supports the measurement of out-of-service duration and out-of-service ratio. The measurement results can be used to analyze the general serving states of NodeBs or cells.

NodeB Blocking and Unblocking


The BSC6810 can block a NodeB by deactivating all the cells controlled by this NodeB. The BSC6810 can also unblock a NodeB by activating all of the cells controlled by this NodeB.

Cell Blocking and Unblocking


The BSC6810 can block or unblock cells. When a cell is blocked, all the connections to the cell are released, and the cell becomes unavailable. After it is unblocked, the cell recovers to be available.

Issue 01 (2008-03-29)

Commercial in Confidence

Page 37 of 66

BSC6810 V200R010 Product Description

Guarantee for VIP Cells and NodeBs


The BSC6810 can provide OM guarantee and service guarantee for VIP cells and NodeBs. Thus, the VIP cells and NodeBs can run stably with high quality of service.
l

OM guarantee means monitoring VIP cells and NodeBs through detailed monitoring items on a specific interface, so that the maintenance engineers can identify faults rapidly and rectify them efficiently. Service guarantee means providing special network planning and configuration for VIP cells and NodeBs, so that they can provide better services. The resources shared between VIP cells, VIP NodeBs, common cells, and common NodeBs are offered preferentially to VIP cells and VIP NodeBs.

Remote Maintenance
The BSC6810 supports remote maintenance by allowing remote access through the Internet or Virtual Private Network (VPN).

Provision of OM Channels for the NodeBs


The BSC6810 provides the following OM channels for NodeBs:
l l

Transparent OM channels, through which you can operate and maintain NodeBs on the LMT of the BSC6810 or on the M2000 Reverse OM channels, through which you can operate and maintain other NodeBs on the local NodeB

4.3.4 Fault Detection


The BSC6810 provides physical layer fault detection, data link layer fault detection, and other fault detection. Physical layer fault detection covers the following aspects:
l l l l l l l

Local E1 loopback test Remote E1 loopback test E1 Bit Error Rate (BER) test E1 loopback detection E1 misconnection test SDH loopback detection FE/GE port fault detection

Data link layer fault detection covers the following aspects:


l l l l l l l l

AAL2 path fault detection IP path fault detection SAAL fault detection SCTP fault detection PPP/MLPPP misconnection test NodeB OM IP over ATM (IPoA) fault detection Iu-PS IPoA fault detection Virtual Connect Link (VCL) CC

Issue 01 (2008-03-29)

Commercial in Confidence

Page 38 of 66

BSC6810 V200R010 Product Description

Other fault detection covers the following aspects:


l l l l l

Inter-Process Communication (IPC) connectivity check Cell common channel fault detection RFN fault detection Clock fault detection Board loading control fault detection

4.3.5 Performance Management


The BSC6810 provides various performance counters for the upper-layer Network Management System (NMS) to facilitate performance analysis and network optimization. By default, the BSC6810 supports two measurement periods. One is the normal period whose duration is 30 minutes, and the other is the short period whose duration is 5 minutes. The latter is used to monitor Key Performance Indicators (KPIs) in real time. A measurement item supports both measurement periods, that is, a measurement item can be included in both a normal-period task and a short-period task. You can register various performance measurement tasks on the M2000. The BSC6810 can store measurement results generated in the past 72 hours.

4.3.6 Alarm Management


The BSC6810 provides advanced fault diagnosis and handling methods, performs relevance analysis of alarms raised from the host, and reports valid alarms to the user. The BSC6810 provides certain functions for maintenance management. These functions are described in the following topics.

Alarm Processing
You can browse alarm information in real time, query history alarm information, and store alarm information. The online help provides detailed troubleshooting methods for each alarm. The BSC6810 can store the history alarm information generated in the past 90 days and at most 100,000 alarms.

Alarm Masking
The BSC6810 allows you to mask derivative alarms to reduce the number of the reported alarms.

Alarm Filtering
The BSC6810 can filter the alarms of a specific object. If an object is filtered, the alarms of this object are not sent to the alarm management system.

Issue 01 (2008-03-29)

Commercial in Confidence

Page 39 of 66

BSC6810 V200R010 Product Description

Alarm Indication
When a fault alarm is generated, the BSC6810 can notify you in the following ways: blinking of the icon, audible indication of the terminal, and audible and visible indications on the alarm box.

Classified Alarm Management


The BSC6810 supports classified management of alarms raised from normal cells and NodeBs and from abnormal ones. The latter can be the following cells and NodeBs: those under commissioning and those not put into use.

4.3.7 Loading Management


The following modes are available for loading program files and data files onto boards of the BSC6810:
l l

Loading from the flash memories of the boards Loading from the BAM

The mode of loading program files and data files onto a board depends on the consistency between the files in the flash memory of the board and those in the BAM. See specifics as follows:
l l

If the files are consistent, the board loads the files from its flash memory. If the files are inconsistent, the board loads the files from the BAM and updates the files in the flash memory of the active workspace on the board, so as to ensure the program and data consistency.

4.3.8 Status Monitoring


The BSC6810 can monitor in real time the system status, including CPU usage, cell performance, connection performance, link performance, and board resources. The BSC6810 can monitor the following cell performance:
l l l l l l l l l l l l l

Pilot transmit (TX) power of the Primary Common Pilot Channel (P-CPICH) UL Received Total Wideband Power (RTWP) DL frequency TX power Number of UEs, including UEs on Dedicated Channels (DCHs), UEs on common channels, HSDPA UEs, and HSUPA UEs Node synchronization UL CAC DL CAC UL equivalent number of users DL equivalent number of users Usage of the code tree Minimum High Speed Downlink Shared Channel (HS-DSCH) power requirement Bit rate provided by the HS-DSCH Bit rate provided by the Enhanced Dedicated Channel (E-DCH)

Issue 01 (2008-03-29)

Commercial in Confidence

Page 40 of 66

BSC6810 V200R010 Product Description

The BSC6810 can monitor the following connection performance:


l l l l l l l l l l l l l l l

Signal-to-Noise Ratio (SNR) and receive (RX) signal code power of a cell Measurement value of Signal-to-Interference Ratio (SIR) of a UL radio link set SIR target of a UL radio link set SIR error value of a UL radio link set Block Error Rate (BLER) of a UL transport channel BLER of a DL transport channel DL code TX power UE TX power BER of a UL physical channel UL traffic volume DL traffic volume UL throughput and bandwidth DL throughput and bandwidth Handover delay Adaptive Multi Rate (AMR) mode

The BSC6810 can monitor the following link performance:


l l l l l l l l l l l l

IMA groups UNI links Fractional ATM links SAAL links IPoA Permanent Virtual Channels (PVCs) IP path QoS AAL2 paths IP paths FE/GE traffic Traffic on PPP links Traffic on MLPPP groups Traffic on SCTP links

The BSC6810 can monitor the board resource, that is, the license.

4.3.9 Message Tracing


The BSC6810 can perform the following types of message tracing:
l l l l l l l

Message tracing on standard interfaces Protocol message tracing on the transport layer Call tracing Tracing on missed neighboring cell configuration Cell message tracing Intra-system inter-module message tracing Message tracing on the serial port after redirection

Issue 01 (2008-03-29)

Commercial in Confidence

Page 41 of 66

BSC6810 V200R010 Product Description


l l l l

IP tracing Call Data Tracing (CDT) CellDT message tracing Location message tracing

The function of message tracing is integrated into the LMT, which facilitates problem identification. The BSC6810 also provides a tool called Trace Viewer, which allows you to view the stored messages.

4.3.10 Log Management


Various logs are available for you to know the running state of the BSC6810 and to troubleshoot faults. The BSC6810 provides the following logs:
l l l l

Operation log: records the operation information of operators in real time. Running log: records the running information of the BSC6810 in real time. Subscriber log: records the calling procedure information, which, in case of calling failure, is exported to the BAM for problem identification. Cell log: records the cell procedure information, which, in case of cell abnormality, is exported to the BAM for problem identification.

4.3.11 Software Management


The BSC6810 provides certain functions for software management. These functions are described in the following topics.

Online Patching
The BSC6810 supports online patching without disrupting ongoing services. Patches are provided in patch packages. The BSC6810 supports totally and, in some cases, partially one-push solution to facilitate the upgrade. In addition, it supports version rollback, which guarantees the stability of the system.

Remote Upgrade
The BSC6810 supports remote upgrade. You can upgrade it on a remote terminal. In addition, the BSC6810 provides automatic upgrade tools, which can reduce human interference and errors.

Seamless Upgrade
The BSC6810 supports seamless upgrade. Through seamless upgrade, the time of service disruption during the upgrade of system in full configuration is less than three minutes, thus improving the upgrade efficiency.

Remote Patching
The BSC6810 supports remote patching. You can perform the following operations on a remote terminal:
l

Patching the BAM The patches include Windows operating system patches of hotfix type and BAM software patches.

Issue 01 (2008-03-29)

Commercial in Confidence

Page 42 of 66

BSC6810 V200R010 Product Description


l

Patching the host of the BSC6810 The patches are specific for DSPs and .bin program files. Querying all the patches on the BSC6810 through MML commands

Online Upgrade of BIOS


The BSC6810 supports online upgrade of the Basic Input Output System (BIOS). It can load BootROM software onto boards through MML commands without disrupting ongoing services.

Online Expansion
You can expand the capacity of the BSC6810 by adding RBSs or service processing boards. After startup, the new board can automatically load programs, obtain intra-system connection data and configuration data, and enter the serving state.

Batch Command Processing


The BSC6810 supports the editing and modification of commands in batches.

Scheduled Task Processing


The BSC6810 supports scheduled tasks. You can preset commands in the system. The system will automatically run the commands at the preset time.

Online Help
The BSC6810 provides the GUI-based online help.

Issue 01 (2008-03-29)

Commercial in Confidence

Page 43 of 66

BSC6810 V200R010 Product Description

5 Reliability
5.1 About This Chapter
This chapter consists of the following sections:
l l l

System Reliability Hardware Reliability Software Reliability

5.2 System Reliability


The system reliability design of the BSC6810 takes into account the following techniques:
l

Load control The system performs load control based on the CPU usage, traffic over each interface, and radio resource load of the system. Thus, the BSC6810 can keep on working in case of CPU overload and resource congestion. In this way, the system reliability is enhanced.

Dynamic sharing of resources in the system The DPUb boards and DSPs work in resource pool mode, that is, all the DSPs in a subrack work as a resource pool. The MPU in a subrack manages and allocates all the user plane resources within the subrack to fulfill intra-subrack sharing of user plane resources. In case of overload, the MPU forwards Radio Resource Control (RRC) connection requests to other subracks, so as to fulfill inter-subrack sharing of user plane resources and intra- and inter-subrack sharing of control plane resources.

Port trunking SCUa boards support port trunking. This function allows data backup in case of link failure, thus preventing inter-plane switchover and cascading switchover and improving the reliability of intra-system communication.

Dual planes for timing signal transmission The BSC6810 provides the dual planes for transmission of timing signals between the GCUa/GCGa and SCUa boards. The active and standby GCUa/GCGa boards are connected to the active and standby SCUa boards through the Y-shaped cables. This connection mode ensures proper working of the timing signals for the system if a single-point failure

Issue 01 (2008-03-29)

Commercial in Confidence

Page 44 of 66

BSC6810 V200R010 Product Description

occurs to the GCUa/GCGa, cable, or SCUa. In addition, with the Y-shaped cable, switchover between GCUa/GCGa boards does not affect the SCUa boards.
l

Transmission port backup


Unchannelized optical ports support MSP 1:1 or MSP 1+1 redundancy. Channelized optical ports support MSP 1:1 backup. FE or GE ports support port backup and load sharing between the ports.

All these improve the reliability of transmission.


l

OM dual planes To improve the reliability of OM channels, the BSC6810 provides the OM dual planes, including dual OMUa boards, dual Ethernet adapters, and dual main control boards.

Crystal Aging Compensation technology The BSC6810 adopts the Huawei-patented Crystal Aging Compensation technology to compensate for frequency deviation caused by the aging of temperature-constant crystal oscillators. This technology protects the clock precision from the influence of the aging of the crystal oscillators and ensures long-term stability and reliability of the system clock.

Dual 48 V power supplies The two independent 48 V power supplies operate at the same time to ensure normal operations in case either of them fails. The failed supply can be restored without a power cut. This improves the reliability and availability of the power system.

5.3 Hardware Reliability


The BSC6810 adopts the reliability design such as board and port backup and load sharing. In addition, the BSC6810 improves the reliability and maintainability by optimizing the fault detection and isolation techniques for boards and the whole system. The hardware reliability design of the BSC6810 takes into account the following techniques:
l

The system uses the multi-level cascaded and distributed cluster control mode. Several CPUs form a cluster processing system. Each module has distinct functions. The communication channels between modules are based on the backup design or anti-suspension/breakdown design. The system uses the redundancy design, as shown in Table 5-1, to support hot swap of boards and backup of important modules. Therefore, the system has great error tolerance.

Table 5-1 Parts redundancy Part GCUa/GCGa SCUa SPUa Redundancy Mode Board redundancy Board redundancy + port trunking on GE ports Board redundancy

Issue 01 (2008-03-29)

Commercial in Confidence

Page 45 of 66

BSC6810 V200R010 Product Description

Part DPUb AOUa POUa UOIa FG2a GOUa GE port on the FG2a or GOUa FE port on the FG2a OMUa

Redundancy Mode Board resource pool Board redundancy + MSP 1:1 optical port redundancy Board redundancy + MSP 1:1 or MSP 1+1 optical port redundancy Board redundancy + MSP 1:1 or MSP 1+1 optical port redundancy Board redundancy Board redundancy Port redundancy or load sharing Port redundancy or load sharing Board redundancy

When an entity fails, the isolation mechanism transfers the services to another entity for processing. After the system finds a faulty board in the resource pool, it isolates the board. Then another board in the resource pool will process the subsequent services. When a board with a single function fails, restarting the system might clear the fault. All boards support dual-BIOS. Faults at one BIOS do not affect startup or operation of the boards. The system uses the non-volatile memory to store important data. With advanced integrated circuits, the system features high integration, good technology, and high reliability. All the parts of the system pass the aging test. The process of hardware assembly is strictly controlled. These methods ensure the high stability and reliability for long-term operation.

l l l l l

5.4 Software Reliability


The error tolerance ability of the software system indicates the software reliability. In other words, the whole system can keep on working in case of software failure. This indicates that the system has self-healing ability. The BSC6810 derives this ability from the following aspects:
l

Regular check of key resources Usage check is provided for various software resources in the system. If a resource is unavailable because of a software error, the unavailability lasts only a short time. The reason is that the check mechanism ensures the release of this resource and the output of logs and alarms.

Task monitoring

Issue 01 (2008-03-29)

Commercial in Confidence

Page 46 of 66

BSC6810 V200R010 Product Description

During the running of software, the BSC6810 monitors the internal errors of all software and some hardware faults, if any. It then reports the errors and faults to the OM system.
l

Load sharing The FG2a and GOUa boards support inter-board load sharing between ports. The DPUb boards work in resource pool mode. If a DPUb board is faulty, other DPUb boards in the same subrack take over the services carried on the faulty board.

Data check The system is able to perform regular or event-driven check for data consistency and export the related log records and alarms.

Dual versions The boards of the BSC6810 have active/standby workspaces. The active workspace stores the current version files, and the standby workspace stores the version files except those in the active workspace. Switchover between the active and standby workspaces can be performed to upgrade or roll back the RNC version. Therefore, the active and standby workspaces facilitate the upgrade of and rollback for the RNC and greatly reduce the time of service disruption caused by the upgrade.

Data backup The BAM data and FAM data can be backed up, so that the reliability and consistency of the data are ensured. Storage of operation information The BSC6810 records the operations that you perform and saves the records in the operation log. You can use the operation log to identify and clear errors or faults caused by operations.

Flow control The BSC6810 automatically controls the flows on the Iub, Iur, and Iu interfaces to avoid overload caused by heavy traffic.

Issue 01 (2008-03-29)

Commercial in Confidence

Page 47 of 66

BSC6810 V200R010 Product Description

6 Technical Specifications
6.1 About This Chapter
This chapter consists of the following sections:
l l l l l l l l l l l l

Performance Specifications Transmission Port Specifications GPS Feeder Specifications Reliability Specifications Structural Specifications Electrical Specifications Power Consumption in Typical Configurations Clock Precision Specifications Noise and Safety Compliance Environmental Protection Specifications International Protection Specifications Environmental Requirements

6.2 Performance Specifications


Table 6-1 describes the performance specifications for the BSC6810. Table 6-1 Performance specifications Item Maximum number of cabinets Maximum number of subracks BHCA Maximum traffic volume PS throughput (UL + DL) Maximum number of NodeBs Specification 2, that is, 1 RSR and 1 RBR 6, that is, 1 RSS and 5 RBSs 2,000k (calculated on the basis of Huawei traffic model) 60,000 Erlang (calculated on the basis of Huawei traffic model) 3,840 Mbit/s 1,700

Issue 01 (2008-03-29)

Commercial in Confidence

Page 48 of 66

BSC6810 V200R010 Product Description

Item Maximum number of cells

Specification 5,100

6.3 Transmission Port Specifications


Table 6-2 describes the transmission port specifications for the BSC6810. Table 6-2 Transmission port specifications Transmission Type Standard Board or Port Type AEUa E1/T1 ITU-T G.703/G.704 PEUa DB44 Connector Type DB44 Remarks The AEUa provides 32 E1s/T1s for ATM transport on the Iub interface. The PEUa provides 32 E1s/T1s for IP transport on the Iub interface. The AOUa provides 2 channelized STM-1/OC-3 optical ports for ATM transport on the Iub interface. The POUa provides 2 channelized STM-1/OC-3 optical ports for IP transport on the Iub interface. The UOIa provides 4 unchannelized STM-1/OC-3c optical ports for ATM transport on the Iub, Iur, and Iu interfaces. UOIa LC/PC The UOIa provides 4 unchannelized STM-1/OC-3c optical ports for IP transport on the Iub, Iur, and Iu interfaces. FE port on the FG2a GE electrical port on the FG2a GE IEEE 802.3 GE optical port on the GOUa LC/PC The GOUa provides 2 GE optical ports for IP transport on the Iub, Iur, and Iu interfaces. RJ45 The FG2a provides 8 FE ports for IP transport on the Iub, Iur, and Iu interfaces. The FG2a provides 2 GE electrical ports for IP transport on the Iub, Iur, and Iu interfaces.

ITU-T G.957 ITU-T I.432.1 ITU-T I.432.2

AOUa

LC/PC

Channelized STM-1/OC-3

l l

POUa

LC/PC

ITU-T G.957 ITU-T I.432.1 ITU-T I.432.2

Unchannelized STM-1/OC-3c

l l

FE

IEEE 802.3

RJ45

Issue 01 (2008-03-29)

Commercial in Confidence

Page 49 of 66

BSC6810 V200R010 Product Description

The maximum transmission distances of different port types are as follows:


l l l l l

E1/T1 port: 500 m STM-1 port: 15 km FE port: 100 m GE electrical port on the FG2a: 100 m GE optical port on the GOUa: 10 km

6.4 GPS Feeder Specifications


The BSC6810 provides GPS feeders that meet the following specifications:
l l l

Length of the GPS feeder

100 m 300 m 500 m

100 m < length of the GPS feeder 300 m < length of the GPS feeder

6.5 Reliability Specifications


Table 6-3 describes the reliability specifications for the BSC6810. Table 6-3 Reliability specifications Item System inherent availability Mean Time Between Failures (MTBF) System restarting time Mean Time To Repair (MTTR) Specification 99.999% 347,700 h 10 min 1h

6.6 Structural Specifications


Table 6-4 describes the structural specifications for the BSC6810. Table 6-4 Structural specifications Item Cabinet standard Specification The structural design conforms to the IEC60297 standard and IEEE standard.
l

Dimensions of a cabinet
l

N68E-22 cabinet: 2,200 mm (height) x 600 mm (width) x 800 mm (depth) N68-21-N cabinet: 2,133 mm (height) x 600 mm

Issue 01 (2008-03-29)

Commercial in Confidence

Page 50 of 66

BSC6810 V200R010 Product Description

Item

Specification (width) x 800 mm (depth)

Height of the available space in a cabinet Weight of a single cabinet Load bearing capacity of the equipment room

l l l l

N68E-22 cabinet: 46 U N68-21-N cabinet: 44 U N68E-22 cabinet: N68-21-N cabinet: 350 kg 410 kg

450 kg/m 2

6.7 Electrical Specifications


Table 6-5 describes the electrical specifications for the BSC6810. Table 6-5 Electrical specifications Item Power supply Electromagnetic Compatibility (EMC) RSS power consumption RBS power consumption Power consumption of the RSR in full configuration Power consumption of the RBR in full configuration Specification
l l

48 V DC power Input voltage range: 40 V to 57 V

Meets the requirements in ETSI EN300 386 and Council directive 89/336/EEC 1,530 W 1,540 W 4,650 W 4,660 W

6.8 Power Consumption in Typical Configurations


Table 6-6 describes the specifications of the power consumption of the BSC6810 in typical configurations.

Issue 01 (2008-03-29)

Commercial in Confidence

Page 51 of 66

BSC6810 V200R010 Product Description

Table 6-6 Power consumption of the BSC6810 in typical configurations Number of Subracks Iu/Iur/Iub ATM Optical Transport with Ports in Redundancy 1,570 W 3,110 W 4,650 W 6,230 W 7,770 W 9,310 W Iu/Iur/Iub GE Optical Transport with Ports Not in Redundancy 1,260 W 2,400 W 3,540 W 4,720 W 5,860 W 7,000 W Traffic Volume (Erlang) 6,000 16,800 27.600 38,400 49,200 60,000 (UL + DL) PS Throughput (Mbit/s) 384 1,075 1,766 2,458 3,149 3,840 Number of Cells

1 RSS 1 RSS + 1 RBS 1 RSS + 2 RBSs 1 RSS + 3 RBSs 1 RSS + 4 RBSs 1 RSS + 5 RBSs

600 1,500 2,400 3,300 4,200 5,100

6.9 Clock Precision Specifications


The precision of the clock for the BSC6810 meets the associated requirements of the stratum 3 clock.

6.10 Noise and Safety Compliance


Table 6-7 describes the noise and safety compliance for the BSC6810. Table 6-7 Noise and safety compliance Item Noise Specification < 72 dB; fulfilling the requirements in EUROPEAN ETS 300 753 Fulfilling the requirements in:
l l l

IEC 60950 EN 60950 UL60950 IEC 60825-1 IEC 60825-2 AS/NZS 60950-1 GB4943-2001

Safety

l l l l

Issue 01 (2008-03-29)

Commercial in Confidence

Page 52 of 66

BSC6810 V200R010 Product Description

6.11 Environmental Protection Specifications


The environmental protection specifications for the BSC6810 are as follows:
l l

RoHS: Restriction of the Use of Certain Hazardous Substances in Electrical and Electronic Equipment WEEE: The EU Directive on Waste of Electrical and Electronic Equipment

6.12 International Protection Specifications


The BSC6810 reaches the protection degree of IP50.

6.13 Environmental Requirements


The storage, transportation, and working environments of the BSC6810 conform to the following standards:
l l l l l l l

GB2423.1-1989 GB2423.2-1989 GB2423.4-1993 GB2423.22-1987 GB/T13543 ETS 300 019 NEBS GR-63-core

6.13.1 Storage Environment


The BSC6810 has storage requirements for climate, waterproofing conditions, biological environment, air purity, and mechanical stress.

Climatic Requirements
Table 6-8 describes the climatic requirements for storing the BSC6810. Table 6-8 Climatic requirements for storing the BSC6810 Item Temperature Temperature change rate Relative humidity Altitude Air pressure Solar radiation Thermal radiation Specification 40C to +70C 1C/min 10% to 100% RH 5,000 m 70 kPa to 106 kPa 1,120 W/m 600 W/m

Issue 01 (2008-03-29)

Commercial in Confidence

Page 53 of 66

BSC6810 V200R010 Product Description

Item Wind speed

Specification 30 m/s

Waterproofing Requirements
The waterproofing requirements for storing the BSC6810 are as follows:
l l l

The equipment is usually stored in a room. There is no water on the floor or any water entering the package. In the equipment room, there is no water that may damage the equipment, such as water from automatic fire protection devices or the air conditioner.

If the equipment has to be placed outdoors, ensure that:


l l l l

The package is intact. Waterproofing measures are taken to prevent rainwater from entering the package. There is no water on the ground or any water entering the package. The package is not exposed to direct sunlight.

Biological Requirements
The biological requirements for storing the BSC6810 are as follows:
l l

No fungus or mildew may grow in the equipment room or near the equipment. The place is free from rodents, such as rats.

Air Purity Requirements


The air purity requirements for storing the BSC6810 are as follows:
l l l

The air is free from explosive, conductive, magnetically conductive, or corrosive dust. The density of physically active materials must meet the requirements listed in Table 6-9. The density of chemically active materials must meet the requirements listed in Table 6-10.

Table 6-9 Storage requirements for physically active materials Physically Active Material Suspended dust Falling dust Sand Unit mg/m mg/mh mg/m Density 5.00 20.0 300

Issue 01 (2008-03-29)

Commercial in Confidence

Page 54 of 66

BSC6810 V200R010 Product Description

Physically Active Material


l l l

Unit

Density

Note: Suspended dust: diameter Falling dust: 75 m Sand: 150 m diameter

75 m 150 m 1,000 m

diameter

Table 6-10 Storage requirements for physically active materials Chemically Active Material SO2 H2S NO2 NH3 Cl2 HCl HF O3 Unit mg/m mg/m mg/m mg/m mg/m mg/m mg/m mg/m Density 0.30 0.10 0.50 1.00 0.10 0.10 0.01 0.05

Mechanical Stress Requirements


Table 6-11 describes the mechanical stress requirements for storing the BSC6810. Table 6-11 Mechanical stress requirements for storing the BSC6810 Item Sub-item Offset Sinusoidal vibration Accelerated speed Frequency range Impact response spectrum II Static payload 2 Hz to 9 Hz 250 m/s 5 kPa Specification 7.0 mm 20.0 m/s 9 Hz to 200 Hz

Unsteady impact

Issue 01 (2008-03-29)

Commercial in Confidence

Page 55 of 66

BSC6810 V200R010 Product Description

Item

Sub-item

Specification

Note: l Impact response spectrum: maximum acceleration response curve generated by the equipment under specified impact excitation Impact response spectrum II means that the duration of semi-sine impact response spectrum is 6 ms. l Static payload: capability of the equipment in package to bear the pressure from the top in normal pile-up method

6.13.2 Transportation Environment


The BSC6810 has transportation requirements for climate, waterproofing conditions, biological environment, air purity, and mechanical stress.

Climatic Requirements
Table 6-12 describes the climatic requirements for transporting the BSC6810. Table 6-12 Climatic requirements for transporting the BSC6810 Item Temperature Temperature change rate Relative humidity Altitude Air pressure Solar radiation Thermal radiation Wind speed Specification 40C to +70C 3C/min 5% to 100% RH 5,000 m 70 kPa to 106 kPa 1,120 W/ m 600 W/ m 30 m/s

Waterproofing Requirements
The waterproofing requirements for transporting the BSC6810 are as follows:
l l l

The package is intact. Waterproofing measures are taken to prevent rainwater from entering the package. The inside of the vehicle is completely dry.

Biological Requirements
The biological requirements for transporting the BSC6810 are as follows:
l

No fungus or mildew may grow in the vehicle.

Issue 01 (2008-03-29)

Commercial in Confidence

Page 56 of 66

BSC6810 V200R010 Product Description


l

The place is free from rodents, such as rats.

Air Purity Requirements


The air purity requirements for transporting the BSC6810 are as follows:
l l l

The air is free from explosive, conductive, magnetically conductive, or corrosive dust. The density of physically active materials must meet the requirements listed in Table 6-13. The density of chemically active materials must meet the requirements listed in Table 6-14.

Table 6-13 Transportation requirements for physically active materials Physically Active Material Suspended dust Falling dust Sand Unit mg/m mg/mh mg/m Density No requirement 3.0 100

Note: l Suspended dust: diameter 75 m l Falling dust: 75 m diameter 150 m l Sand: 150 m diameter 1,000 m

Table 6-14 Transportation requirements for chemically active materials Chemically Active Material SO2 H2S NO2 NH3 Cl2 HCl HF O3 Unit mg/m mg/m mg/m mg/m mg/m mg/m mg/m mg/m Density 0.30 0.10 0.50 1.00 0.10 0.10 0.01 0.05

Mechanical Stress Requirements


Table 6-15 describes the mechanical stress requirements for transporting the BSC6810.

Issue 01 (2008-03-29)

Commercial in Confidence

Page 57 of 66

BSC6810 V200R010 Product Description

Table 6-15 Mechanical stress requirements for transporting the BSC6810 Item Sub-item Offset Sinusoidal vibration Accelerated speed Frequency range Spectrum density of accelerated speed Frequency range Impact response spectrum II Static payload 2 Hz to 9 Hz 10 m/s 2 Hz to 9 Hz 300 m/s 10 kPa Specification 7.5 mm 20.0 m/s 9 Hz to 200 Hz 3 m/s 9 Hz to 200 Hz 40.0 m/s 200 Hz to 500 Hz 1 m/s 200 Hz to 500 Hz

Random vibration

Unsteady impact

Note: l Impact response spectrum: maximum acceleration response curve generated by the equipment under specified impact excitation Impact response spectrum II means that the duration of semi-sine impact response spectrum is 6 ms. l Static payload: capability of the equipment in package to bear the pressure from the top in normal pile-up method

6.13.3 Working Environment


The BSC6810 has working environment requirements for climate, biological environment, air purity, and mechanical stress.

Climatic Requirements
Table 6-16 and Table 6-17 describe the climatic requirements for operating the BSC6810. Table 6-16 Temperature and humidity requirements for operating the BSC6810 Temperature Normal 0C to 45C Safe 5C to +55C Relative Humidity Normal 5% to 85% RH Safe 5% to 95% RH

Note: l The values are measured 1.5 m above the floor and 0.4 m in front of the equipment, without protective panels in front of or behind the cabinet. l Safe refers to continuous operation for not more than 96 hours or accumulated operation for not more than 15 days in a year.

Issue 01 (2008-03-29)

Commercial in Confidence

Page 58 of 66

BSC6810 V200R010 Product Description

Table 6-17 Other climatic requirements for operating the BSC6810 Item Altitude Air pressure Temperature change rate Solar radiation Thermal radiation Wind speed Specification 4,000 m 70 kPa to 106 kPa 3C/min 700 W/m 600 W/m 5 m/s

Biological Requirements
The biological requirements for operating the BSC6810 are as follows:
l l

No fungus or mildew may grow in the area where the equipment is operated. The place is free from rodents, such as rats.

Air Purity Requirements


The air purity requirements for operating the BSC6810 are as follows:
l l l

The air is free from explosive, conductive, magnetically conductive, or corrosive dust. The density of physically active materials must meet the requirements listed in Table 6-18. The density of chemically active materials must meet the requirements listed in Table 6-19.

Table 6-18 Working environment requirements for physically active materials Physically Active Material Dust particles Unit Particles/m Density 3 x 104 (no visible dust on the desktop within three days)

Note: Dust particles: diameter 5 m

Table 6-19 Working environment requirements for chemically active materials Chemically Active Material SO2 H2S NH3 Unit mg/m mg/m mg/m Density 0.20 0.006 0.05

Issue 01 (2008-03-29)

Commercial in Confidence

Page 59 of 66

BSC6810 V200R010 Product Description

Chemically Active Material Cl2

Unit mg/m

Density 0.01

Mechanical Stress Requirements


Table 6-20 describes the mechanical stress requirements for operating the BSC6810. Table 6-20 Mechanical stress requirements for operating the BSC6810 Item Sub-item Offset Sinusoidal vibration Accelerated speed Frequency range Impact response spectrum II Static payload 0 2 Hz to 9 Hz 100 m/s Specification 3.5mm 10.0 m/s 9 Hz to 200 Hz

Unsteady impact

Note: l Impact response spectrum: maximum acceleration response curve generated by the equipment under specified impact excitation Impact response spectrum II means that the duration of semi-sine impact response spectrum is 6 ms. l Static payload: capability of the equipment in package to bear the pressure from the top in normal pile-up method

Issue 01 (2008-03-29)

Commercial in Confidence

Page 60 of 66

BSC6810 V200R010 Product Description

7 Installation
7.1 About This Chapter
This chapter consists of the following sections:
l l

Hardware Installation Software Installation

7.2 Hardware Installation


During hardware installation, adhere to the following principles:
l

The height of the equipment room is not less than 3,000 mm. The height refers to the distance between the lowest level of the ceiling and the highest position of the floor. The aisle between two rows of cabinets is at least 1,000 mm wide. The cabinet is not installed against the wall. For a cabinet that is closest to the wall, the distance between the wall and the lateral/front/rear side of the cabinet is at least 800 mm. An aisle of at least 1,000 mm in width is reserved in the equipment room.
Do not install the cabinet against the wall.

l l

Issue 01 (2008-03-29)

Commercial in Confidence

Page 61 of 66

BSC6810 V200R010 Product Description

Figure 7-1 shows the equipment room floor plan. Figure 7-1 Equipment room floor plan (unit: mm)

l l l

The BSC6810 supports both overhead and underfloor cabling. The BSC6810 supports both front and back maintenance. The BSC6810 does not support back-to-back installation of cabinets. Interconnect the cabinets side by side if necessary.

For details about the environmental requirements of the BSC6810, refer to section 6.13 "Environmental Requirements."

7.3 Software Installation


The software can be easily installed on the engineering site. Before delivery, plenty of internal data is automatically generated or configured. You need to install only the BAM software and LMT software during either initial installation or upgrade.

Issue 01 (2008-03-29)

Commercial in Confidence

Page 62 of 66

BSC6810 V200R010 Product Description

A
2G 3G 3GPP AAL2 AAL5 AMR ARP ATM BAM BE BER BFD BHCA BIOS BITS BLER BOOTP CAC CBC CC CCP CDT CN

Acronyms and Abbreviations

The Second Generation The Third Generation Third Generation Partnership Project ATM Adaptation Layer type 2 ATM Adaptation Layer type 5 Adaptive Multi Rate Address Resolution Protocol Asynchronous Transfer Mode Back Administration Module Best Effort Bit Error Rate Bidirectional Forwarding Detection Busy Hour Call Attempt Basic Input Output System Building Integrated Timing Supply System Block Error Rate Bootstrap Protocol Call Admission Control Cell Broadcast Center Continuous Check Communication Control Port Call Data Tracing Core Network

Issue 01 (2008-03-29)

Commercial in Confidence

Page 63 of 66

BSC6810 V200R010 Product Description

CPU CS DC DCH DHCP DL DSP E-DCH EMC EMS ETS ETSI FAM FE FP FP MUX FTP GBR GE GPRS GPS GTP-U GUI HSDPA HS-DSCH HSUPA IEEE IMA IMS IP IPC IPoA ITU-T

Central Processing Unit Circuit Switched Direct Current Dedicated Channel Dynamic Host Configuration Protocol Downlink Digital Signal Processor Enhanced Dedicated Channel Electromagnetic Compatibility Element Management System European Telecommunication Standard European Telecommunications Standards Institute Front Administration Module Fast Ethernet Frame Protocol Frame Protocol Multiplexing File Transfer Protocol Guaranteed Bit Rate Gigabit Ethernet General Packet Radio Service Global Positioning System GPRS Tunneling Protocol for User Plane Graphic User Interface High Speed Downlink Packet Access High Speed Downlink Shared Channel High Speed Uplink Packet Access Institute of Electrical and Electronics Engineers Inverse Multiplexing on ATM IP Multimedia Subsystem Internet Protocol Inter-Process Communication Internet Protocols over ATM International Telecommunication Union - Telecommunication

Issue 01 (2008-03-29)

Commercial in Confidence

Page 64 of 66

BSC6810 V200R010 Product Description

Standardization Sector KPI LAN LED LMT MAC MBMS MDC MGW MIMO MLPPP MML MSC MSP MTBF MTP3-b MTTR NBAP NCP NE NMS OM PARC P-CPICH PDCP PPP PS PVC QoS RANAP RBR RBS RFN Key Performance Indicator Local Area Network Light Emitting Diode Local Maintenance Terminal Medium Access Control Multimedia Broadcast and Multicast Service Macro Diversity Combining Media Gateway Multi-Input Multi-Output Multilink PPP Man Machine Language Mobile Switching Center Multiplex Section Protection Mean Time Between Failures Message Transfer Part level 3 - broadband Mean Time To Repair NodeB Application Protocol NodeB Control Port Network Element Network Management System Operation and Maintenance Platform of Advanced Radio Controller Primary Common Pilot Channel Packet Data Convergence Protocol Point-to-Point Protocol Packet Switched Permanent Virtual Channel Quality of Service Radio Access Network Application Part RNC Business Rack RNC Business Subrack RNC Frame Number

Issue 01 (2008-03-29)

Commercial in Confidence

Page 65 of 66

BSC6810 V200R010 Product Description

RLC RNC RNSAP RRC RRM RSR RSS RTWP RX SAAL SABP SCTP SDH SGSN SIR SNR SRNS SS7 SSL STM-1 TDM TX UDP UE UL UMTS UTRAN VCL VLAN VoIP VPN WCDMA

Radio Link Control Radio Network Controller Radio Network Subsystem Application Part Radio Resource Control Radio Resource Management RNC Switching Rack RNC Switching Subrack Received Total Wideband Power Receiver/Reception/Receive Signaling ATM Adaptation Layer Service Area Broadcast Protocol Stream Control Transmission Protocol Synchronous Digital Hierarchy Serving GPRS Support Node Signal-to-Interference Ratio Signal-to-Noise Ratio Serving Radio Network System Signaling System Number 7 Security Socket Protocol Synchronous Transport Mode-1 Time Division Multiplexing Transmitter/Transmit User Datagram Protocol User Equipment Uplink Universal Mobile Telecommunications System UMTS Terrestrial Radio Access Network Virtual Connect Link Virtual Local Area Network Voice over IP Virtual Private Network Wideband Code Division Multiple Access

Issue 01 (2008-03-29)

Commercial in Confidence

Page 66 of 66

Vous aimerez peut-être aussi