BSS TROUBLESHOOTING GUIDE

1 BSC

2 RNC

3 TRANSMISSION

4 BTS

BSS TROUBLESHOOTING GUIDE

OSS connectivity down - both x.25 down One X.25 down NSEI Down BVCI Down Zero Voice calls on particular Cell Unit re-start SIGNALLING LINK OVERLOAD SIGNALLING LINK DOWN SIGNALLING LINK ACTIVATION OR RESTORATION FAILURE SIGNALLING LINK SET DOWN GPRS/EDGE LOAD IS VERY HIGH IN PCU OF PSE BTS AND TC UNSYNCHRONIZATION CLEAR CALLS ON ABIS INTERFACE WDU FAULTY STMU FAULTY MCMU RESTART BCSU RESTART BCSU SWITCHOVER

Iu-CS link down Both Iu-PS links down One Iu-PS link down BASE STATION FAULTY BASE STATION OPERATION DEGRADED BASE STATION NOTIFICATION CELL FAULTY CELL OPERATION DEGRADED CELL NOTIFICATION BASE STATION LICENCE NOTIFICATION BASE STATION TRANSMISSION ALARM BEATING WCDMA BTS ALARM FAILURE IN WCDMA WBTS O&M CONNECTION RNW O&M SCENARIO FAILURE WCDMA CELL OUT OF USE HSDPA CONFIGURATION FAILED WCDMA BTS DEDICATED MEASUREMENT FAILURE HSUPA FAILURE IN WCEL WCDMA BASE STATION OUT OF USE

BFD Down in AXC (Tellabs) 3G Sites down 2G or 3G sites down (Mw ring collapsed) 2G/3G multiple sites down

SYNCHRONISATION IS MISSING Some Subscribers not able to latch on TATA network from specific handsets Rx levels differ too much between main and diversity antennas, RSSI detected Rx signal difference exceeding EXxx TRX module cooling fan s report no rotation,ESMA System module cooling fan s report no rotation ERxx DDU module has detected VSWR above minor limit at anten

S. No.

Problem

Alarm No. at BSC

Alarm Description / Comments

Catergory

OSS connectivity down - both x.25 down

2175

OSI CLNS LINKAGE NOT AVAILABLE

One X.25 down

2175

OSI CLNS LINKAGE NOT AVAILABLE

NonService affecting

NSEI Down

3315

ALL NETWORK SERVICE ENTITIES UNAVAILABLE

BVCI Down

Service affecting

Service affecting

non-Service affecting

Service affecting

BVCI Down

Zero Voice calls on particular Cell

7738

BTS WITH NO TRANSACTIONS

SIGNALLING LINK OVERLOAD

26

SIGNALLING LINK LOAD OVER THRESHOLD

SIGNALLING LINK DOWN

1072

SIGNALLING LINK OUT OF SERVICE

SIGNALLING LINK ACTIVATION OR RESTORATION FAILURE SIGNALLING LINK SET DOWN GPRS/EDGE LOAD IS VERY HIGH IN PCU OF PSE

2072

FAILURE IN SIGNALLING LINK ACTIVATION OR RESTORATION

10

2070

LINK SET UNAVAILABLE

Service affecting NonService affecting

11

3415

GPRS/EDGE LOAD IS VERY HIGH IN PCU OF PSE

12

BTS AND TC UNSYNCHRONIZ ATION CLEAR CALLS ON ABIS INTERFACE

2993

BTS AND TC UNSYNCHRONIZATION CLEAR CALLS ON ABIS INTERFACE

13

DISK FAILURE

2860

DISK FAILURE

Service affecting

Service affecting

14

WDU FAULTY

2861, 2692

NO ACCESS TO DISK ,INCORRECT WORKING STATE

15

STMU FAULTY

2794

HW BLOCK FAILURE IN PLUG-IN UNIT

16

INCORRECT WORKING 2692 STATE MCMU RESTART 0690,1001 working State Changed , Unit restarted

Service Threatening

Service Threatening

non-Service affecting

17

BCSU RESTART

2692 0690 1001

INCORRECT WORKING STATE working State Changed , Unit restarted

18

BCSU SWITCHOVER

2692 0690 1001

INCORRECT WORKING STATE working State Changed Unit Restarted

19

Loss of Synchronization in BSC

2,641

Failure in Synchronization Signal

Service Threatening

Service Threatening

Service affecting

Affect / Steps to be follow for troubleshoot

1. Check the signalling links states at MSS end 2. If signalling links / link set down means BSC down(Alarm-Link Set Unavailable) 3. Send local engineer at BSC site 4. Check BSC end Mux status & alarm. 1st: Mux unmanaged - check alarm at connected Mux, Power issue at BSC site. 2. Mux managed - check alarm at Mux & verify the power status for BSC. 5. Login BSC via VDU / LANU. Check the alarms & current computer unit status, if login is possible.In case login is not possible ,get login through OMU CPU and check the status of OMU and other computer units.If we will not get the login through OMU also ,raise the emergency and follow steps as per with care team recommandation.

1. Check the signalling links states at MSS end 2. If Signalling links found ok, Check the voice & data traffic at MSS & PACO end (normal or any 3. Check the Transmission path - Is there any alarm in X.25 E1 path / path broken, then re-route path & check X.25 links status. 5. If media ok, Send local engineer at BSC site 6. Locally login the BSC via VDU / LANU & check the alarms. Reset the X.25 ET as well as X.25 links. 7. If BSC not login via VDU / LANU than login through CPU of OMU unit and check the status: after login ask for password then login ok, or if continuously restarting phase means OMU unit faulty. Do as per care team recommendations. 1. Check the Transmission path - Is there any alarm in X.25 E1 path / path broken. 2. Check the alarms. If PCM ok then reset the X.25 ET as well as X.25 links from BSC . Data traffic affect, down Check no. of NESI's down, if down all - Trace PCU IP from SGSN & find last hop address & check media B/W that hop to BSC If only some NSEI down (one or two) follow below steps 1. Check the PCU - BCSU combination 2. Ping SGSN (PAPU) IP from that BCSU-PCU 3. Trace PCU IP from SGSN 4. Shift the traffic (DAP) to other PCU-BCSU 5. During MW Hrs diagnose that BCSU. 1. Diagnose ok make BCSU in WO state and observe the alarm & Data traffic affect, down 1. GENA toggle & check status.

2. Check PCU-BCSU combination: (a) In case a particular PCU-BCSU combination: shift the traffic to other PCU & Switchover BCSU in MW (b) PCU-BCSU combination random on many BCSUPCU combinations - Traffic prevent - unprevent from (c) BCSU switchover. (d) PAPU re-set / switchover . Check hardware, cabling & commissioning

Check UP/DL quality, path imbalance/VSWR/RSSI

This notice appears repeatedly - consider adding more signalling links A signalling link has failed and changed state from IN SERVICE to OUT OF SERVICE, or its initial alignment attempt has failed. Check the Transmission path If there are other path available, signalling links path re-route with discussion with planning team The activation or restoration of a signalling link fails. Signalling transmission capacity decreased. Check the Transmission path If there are other path available, signalling links path re-route with discussion with planning team All signalling links in the signalling link set are Check alarm: 2064 - ROUTE SET UNAVAILABLE. If this alarm presentend to endroute is availablethe Aters Check for the means no connectivity for carrying signalling (MSC,TXN and BSC), transmission Check GPRS/EDGE load & balance the load by reallocate the DAPs Thershold value need to be change or PCU addition require if load balancing ok.

Impact: Call drop, Quality degradation, Call muting Check the Transmission Media, if not ok then clear the path issue. If Transmission Media found OK, then check the timeslot mapping between bts and bsc should be checked. if mapping is fine, timeslot bypassing should be checked for the problem BTS/TRX, and if it is coming on more than one timeslot, and everything else is fine, trx should be replaced and call test should be done on all time slots after replacement. If it is coming for only detected a serious error that may The system has one timeslot, the time slot may be have been caused by the hard disk or the SCSI controller plug-in unit breaking down.Saving data into the hard disk or reading data from the hard disk fails.Run the diagnosis on the faulty hard disk and if

Impact: No hard disk Redundancy, Measurements might be affected. 1.Check the WDU state with ZISI :; commands . Alarm history and current alarm should be checked. If it is one WDU or both WDU are in BL-SY state . 2. Perform the JOJI of harddisk ( with JOJI the HDSAM ) and DCAR card .perform the OMU restart and check .if problem reolved, perform the diagonisis of WDU 1. Check the status of STMU with ZUSI:STMU:; commands. Check the current & History alarms & Site/aters outage if any related to faulty STMU. 2. Check the supplementary information of alarms & work as per information . 3. Clear the faulty tag with ZUST command and observe. 4. Check the alarms of ET/ transmission and set loss with ZYWI command. 5. Temperature condition need to check at BSC location. 6. Check the STMU cabling and if required replace the Hardware.

1. Check the status of computer units with ZUSI:COMP:; commands. Check the current & History alarms. 2. Check the supplementary information of alarms & work as per information (switchover / diagnose). 3. check ZIGO & ZUDH. 4. Change the state of MCMU to SE-NH and perform the JOJI of all cards og MCMU and GSW .after Diagonise the unit and check. 4. if problem repeates on same MCMU ,replace the hardware with help of alarm info. 5. Perform the diagonistics of that MCMU /EMB and make it in working State. 6. If no alarm found or problem occur on different different units with same alarm Number it may be a SW bug. Note : Kindly note before switchoff the MCMU respective MCMU and EMB should be in SE-NH state also during any hardware replacement check the Jumper setting of the card.during any hardware replacement check the Jumper setting of the card.

1. Check the status of computer units with ZUSI:COMP:; commands. Check the current & History alarms. 2. Check the supplementary information of alarms & work as per information (switchover / diagnose). 3. check ZIGO & ZUDH. 4. if problem repeates on same BCSU ,replace the hardware with help of alarm info. 5. Perform the diagonistics of the BCSU with both MCMU and make it in working State. 6. Check the BVCI state and lapd States 7. If no alarm found or problem occur on different different units with same alarm Number it may be a SW bug. Note : During any hardware replacement check the Jumper setting of the card accordingly. 1. Check the status of computer units with ZUSI:COMP:; commands. Check the current & History alarms. 2. Check the supplementary information of alarm & work as per information (switchover / diagnose). 3. check ZIGO & ZUDH. 4. if problem repeates on same BCSU ,replace the hardware with help of alarm info. 5. Perform the diagonistics of the BCSU with both MCMU and make it in working State. 6. Check the BVCI and Lapd state. 7. If no alarm found or problem occur on different different units with same alarm Number it may be a SW bug. Note : During any hardware replacement check the Jumper setting of the card accordingly. 1. Check the ZDRI :; command output with Current alarms. 2. Check the ET alarms on Sync ET . 3. Disconnect the all sync with ZDRC command ,setthe ossilator control word value to 32000 on both CLS and reconnect the all sync inputs with correct priority. Note : If any BSC is out of Sync ,there will be slip on all ETs of that BSC .

S. No.

Problem

Alarm No. at RNC

Alarm Description / Comments

Cateagory

Impact

Iu-CS link down

2070

LINK SET UNAVAILABLE

SA

RNC Total Outage

Both Iu-PS links down

2070

LINK SET UNAVAILABLE

SA

RNC data traffic outage

One Iu-PS link down

2070

LINK SET UNAVAILABLE

NSA

No Data traffic outage

BASE STATION FAULTY 4

7650

No connection to Flexi transport submodule BTS reference clock missing

SA

Transmission to NodeB will be affected

SD

Service will be affected based on the degradtion threshold level

BASE STATION OPERATION DEGRADED

7651

BTS RNC/IHSPA interface signalling link failure System module failure

SA

NBAP/AAL2 signalling link failure

SA

NodeB Capacity may be reduced/NodeB totally may not be opreational

BTS requires restart because license status has changed BTS time not corrected Difference between BTS master clock and reference frequency 6 BASE STATION NOTIFICATION 7652 Fan failure

SA

Mentioned licence feature will not work

NSA

BTS time will not be correct

NSA

BTS frequecy deviates from IuB referecne

NSA

Temparature will be increased Heating from the heating element is not available. The module temperature may not reach the working level or may reach it very slowly

Heating element not working

SA

Temperature alarm

SA

Depending on severity BTS Capacity may be reduced/BTS totally may not be opreational Depending on severity BTS Capacity may be reduced/BTS totally may not be opreational Depending on severity BTS Capacity may be reduced/BTS totally may not be opreational Sectors will be affected depends on severity Depending on severity BTS Capacity may be reduced/BTS totally may not be opreational Sectors Operation will be degraded

CELL FAULTY

7653

Failure in optical RP3 interface Incompatible SW version detected RF module failure VSWR alarm RF module failure

SA

SA

CELL OPERATION DEGRADED

7654

Rx signal level failure

NSA

Sectors Operation will be degraded

CELL NOTIFICATION

7655

Radio resources switched off HW capacity too low for feature 308, Licence Based BTS channel c Licence missing 00000001125, Flexi WCDMA BTS 60W Power License

SA

Cell will be down

NSA

The licenses are granted but cannot be used. Some of the licensed features are not available.

SA

Sector down

10

BASE STATION LICENCE NOTIFICATION

Licence missing 0000000306, HSDPA 16QAM SW Licence Support 7661 Licence missing 0000000307, HSDPA Proportional Fair Resource Pac Licence missing 0000000649, Shared HSDPA Scheduler for Baseband Verification of target ID failed 3 times. License missing for feature Additional 2 E1, T1, JT1 interface o

SA

SDPA Traffic will affect

NSA

Degradation

NSA

Degradation

SA

Degradation of system module

11

BASE STATION TRANSMISSION ALARM

Service Degraded SA

7665

11

BASE STATION TRANSMISSION ALARM

7665 License missing for feature UBR+.

SA

Cell Down

12

BEATING WCDMA BTS ALARM FAILURE IN WCDMA WBTS O&M CONNECTION

7740

(blank)

NSA

Repeatation of any alarm causes

7750

(blank) AAL2 path unblock not accomplished BCCH information updating has failed Common channel deletion has failed NBAP interface type unknown failure

NSA

BTS Cannot be logined remotly & Measurements will not be updated

13

Cell Down

Cell Down

14

RNW O&M SCENARIO FAILURE

7761

SA Cell Down

Cell Down

Block resource request, normal priority Common measurement failure scenario 15 WCDMA CELL OUT OF USE 7771 NBAP link failure Resource status indication, cell disabled WCEL state not WO WCEL state not WO after setup SA

Sector down

Sector down

Sector down

Sector down

Sector down When Site Down Or Sector Down

RNC internal error 16 HSDPA CONFIGURATION FAILED 7772 WBTS rejects the configuration SD

Service Degraded

Service Degraded

WCDMA BTS DEDICATED MEASUREMENT FAILURE 17

7778

SA

DCN state - Disable Or Cell Faulty

A unit (or units),taking care of HSUPA traffic in the WCEL can be faulty 18 HSUPA FAILURE IN WCEL 7780 SA A unit (or units),taking care of HSUPA traffic in the WCEL can be faulty A unit (or units),taking care of HSUPA traffic in the WCEL can be faulty WCDMA BASE STATION OUT OF USE 7786 (blank) SA WBTS will be down

19

Affect / Steps to be follow for troubleshoot Possible Causes Affects: Communication with MSS down: Total outage 1. Check the unit status for any failure and check the current and history alarms 2. Ping & trace MSS control plane and user plane IP 3. Check Association set and association links status and end IP 4. Check connectivity B/W end trace IP to MSS. Affects: Communication with Both SGSN down: Total data Traffic outage 1. Check the unit status for any failure and check the current and history alarms 2. Ping & trace SGSN control plane and user Association set and 3. Check plane IP association links status andend trace 4. Check connectivity B/W end IP IP to MSS. Affects: Communication with one 1. Check the unit status for any failure and check the current 2. Ping & trace SGSN control plane and user Association set and 3. Check plane IP association links status andend trace 4. Check connectivity B/W end IP IP to MSS. Malfunction of Transport Module in System Module Reset System Module/Replace Transport Module in System Module Solution

Site Clock E1 having errors / AIS

Clock E1 Interface needs to be check & Check the SYNC of TXN side

Transmission break or fluctuations

Check transmission configurations and paths

Abnormal functioning of FSM

Reset FSM/Replace FSM

After licence installation BTS not given restart

Restart BTS.

NTP Server IP mismatch

Check NTP server IP it should be same as RNC OMS IP

DAC Valure variations

Set DAC value to standard value

H/W Faulty

Check working status of Fans or replcae FAN units in FSM

Check whether the heating element The heater control connection of the exists at all./ Check the heater FSM is faulty, there is no heater or control connection and that the the heater is faulty. heater is working./ Replace the alarming component. The internal temperature of the RF Module or System Module exceeds the threshold value, or the ambient temperature of the module(s) is outside the specified limits. Abnormal/ failure in optical cable between FSM & FRGP SW Mismatch of BTS Abnormal functioning of FRGP High VSWR Abnormal functioning of FRGP

Check the FAN units in FSM/FRGP

Check the Optical cable connecton between FSM & FRGP/Reset FSM/Replace cable. Recomission BTS with Correct SW version Reset FRGP/FSM/Check interface cables/Replace FRGP Check the VSWR, should be less than 1.3 Reset FRGP/FSM/Check interface cables/Replace FRGP

The RX signal level is less than 112dBm or the difference between the maximum and minimum power Check the VSWR & Antenna cables levels of all RX antennas in the same cell and sector is more than the limit (4 dB).

As per configuration H/W mismatch/unavailability The HW capacity is too low to support all licenses of an optional feature.

Check the cell configration & H/W availbilty at site

Call to GNSC CM Delete the licenses or insert new hardware.

During NodeB commissioning seleted Login to nodeB and change 60W power for sector. parameters of sector power to 20W

HSDPA License Missing Or Cell Down Call to GNSC CM get it clear

License missing

License missing

License missing

License missing

Hanged/config issue/comm issue

Hanged/config issue/comm issue

This basic license missing

GNSC has to load this basic license from Netact

HSDPA License Missing

GNSC has to load this basic license from Netact Cancels once causing Alarm is cleared To be checked DCN Configrations at RNC/NodeB/Tellabs

Repeatation of any alarm causes

DCN Configuration mismimatch in NodeB/RNC/tellabs

To be checked CoCo/ATM CoCo/ATM Configuration Mismatches Configuration Mismatches between between NodeB/RNC/Tellabs NodeB/RNC/Tellabs To be checked CoCo/ATM CoCo/ATM Configuration Mismatches Configuration Mismatches between between NodeB/RNC/Tellabs NodeB/RNC/Tellabs To be checked CoCo/ATM CoCo/ATM Configuration Mismatches Configuration Mismatches between between NodeB/RNC/Tellabs NodeB/RNC/Tellabs To be checked CoCo/ATM CoCo/ATM Configuration Mismatches Configuration Mismatches between between NodeB/RNC/Tellabs NodeB/RNC/Tellabs

Cell Down

Need to check WCELL/WBTS alarm

Cell Down

Need to check WCELL/WBTS alarm

Cell Down

Need to check WCELL/WBTS alarm

Cell Down

Need to check WCELL/WBTS alarm

Cell Down Cell Down

Need to check WCELL/WBTS alarm Once Node-b is up, alarm will clear

Node-B Lock & Unlock Or Restart Node-B / Cross check & Rectify Cell Down / Interface Down Or H/W Node-B H/W Configuration --All This configuration In Node-B action based on Sublimentory information of Alarm Node-B Lock & Unlock Or Restart Cell Down / Interface Down Or H/W Node-B / Cross check Node-B H/W configuration In Node-B Configuration --All This action based on supplementary Alarm Info. DCN Interface / Lock all the cells under the BCF and delete & ReDCN connected E1 Interface needs to create COCO configuration and be cross check unlock all the cells / If required Site reset has to be given ( Anlaysis based on supplementary info) Cell Down A unit (or units),taking care of HSUPA traffic in the WCEL can be faulty A unit (or units),taking care of HSUPA traffic in the WCEL can be faulty A unit (or units),taking care of HSUPA traffic in the WCEL can be faulty Check the transmission path & Configuration between NodeB to RNC

Cell Down

Cell Down

CNBAP/BRM Break

S. No.

Problem

Alarm No. at BSC

Alarm Description / Comments

Catergory

BFD Down in AXC (Tellabs)

7665

BFD down

Service Degradation

3G Sites down

Base Station out use

Service affecting

2G or 3G sites down (Mw ring collapsed)

Fault rate monitoring & PCM failures

Service affecting

2G/3G multiple sites down

Fault rate monitoring & PCM failures

Service affecting

M/W Link Problem

No Alarm observed in the link, except RSL dip at one end.

At one end, RSL of the link is OK, on other end it dips to -90dBm. No typical alarm observed in the link.

Service Threatning

Affect / Steps to be follow for troubleshoot BFD down or fluctutating in AXC & data traffic shifted to ATM, Cause HSPA fallback enabled. Checked txn media as well as ISA card or reset Mux ISA card to restore BFD. Need to check utilization of GE ports, If broadcast packets incresing then need to check the txn- media & ISA card. Deimplement trails for culprits ISA & raplace ISA ASAP. Downs sites need to be check belongs particular AXC card or Mux particular STM-1 port. Need to check alarms on port, If any alarm appears then switch to redundant port to restore sites If the CPU utilization for both Main & Spare IFMcard are hign then remove one by one & inserted Main card to reduce CPU utilization. Atlast switched CDC card from main to redundant card.

Need to check alrams on ALU mux port during ring collapsed at both end. Need to ping connecting IDU from GNOC to check alarms & w.r.t appeared alarms we identify either power issue or hardware fault Enginners need to send at site with hardware for further trouble shooting. Sites need to be indentified on particular MUX Core mux malfunctioning at BSC/RNC location 2G & 3G site database shared with all CTLs Impact: Microwave Link gets down Reason of the problem: Normally in this type of scenario, ODU of the link (at the end where RSL is OK) is misbehaving. Its transmitor gets off, stops radiating. But, it receives the signal properly.

Troubleshooting: ODU to be replaced

S. No. Problem

BTS Type

1 SYNCHRONISATION IS MISSING All External Q1 device fail to respond

Flexi/MR

Alarm Alarm Description / Comments No. at BSC 7787 DFCA not working in that particular Site,One more Observation:Site will continously restart when DFCA is enabled in the site

2 a)Some Subscribers were not able Flexi Edge to latch on TATA network from BTS specific handsets.While Same Handsets were running fine with IDEA or any other operator from a perticular site (N_UW_NRA_001,Muzzafarnagar)

Observation:At Problematic location/Premises(N_UW_NRA_001,Muzzafa rnagar) there are two NSN equipments serving for IDEA/TATA.No alarm was found on problematic site.

3 Rx levels differ too much between Flexi main and diversity antennas, RSSI detected Rx signal difference exceeding threshold

7607 Rx levels differ too much between main and diversity antennas, RSSI Value is high than 10.

4 EXxx TRX module cooling fan s report no rotation,ESMA System module cooling fan s report no rotation

Flexi

7607 TRX cooling fan not rotate ESMA cooling Fan not rotate

5 a)ERxx DDU module has detected VSWR above minor limit at anten

Flexi/MR

7607 VSWR limit is high than 1.5 for Minor alarm and >2.7 for major alarm

Catergory

Affect / Steps to be follow for troubleshoot

Service affecting 1.First step to check the site is down or not (ZEOL) 2.if site is working with DFCA unsync and LMU is in stand by mode (ZEFL) than visit the site 3.Check the parameters such as LMU area parameter,DFCA disabled or enabled 4.Check ESLA cable connectivity between ESMA to LMU ,if found any Service affecting Activities steps as follow:1.Firstly we Check Infra condition of the site 2.Check the BTS configuration of the site ,properly check weather there is any alarm in site,But no service affecting/Service degrading alarm found 3.After that we check DAC value,RSSI comparision value and VSWR value with Site master but problem not resolved. 4.Change the PLMN allowed from 1 upto 7. 5.Replaced the ESMA card. 6.Shift BCCH to another TRX and check 7.Shift BCCH to another TRX and check. 8.Swapping of TRX's from other perfet site to problamatic site and check. 9.Site deletion and further recreation done still no improvement found 10.Rehome the site BCF-22/ Muzaffarnagar BSC to Meerut -1 BSC with Service 1.Check the RSSI measurements with BTS Manager. Degrading 2.Check the BTS RF cables and connections.Check the antenna and RX cabling. 3.If the antenna and RX cabling are faulty, correct the problem and run TRX test to cancel the alarm. 4.Check and measure VSWR of the antenna lines. Service 1.90% there is a chance of Over heating or Room tempurature high inside Degrading shelter 2.if there in an issue of tempurature resolve the issue along with IP 3.Check that the fan unit cable is correctly connect to DTRX/ESMA 4.Check that there are no obstacles preventing the fan(s) from rotating 5.Clean the fan unit of dust and/or dirt 6.if problem is still presist then Replace the fan unit service affecting 1.Measure VSWR value with Site Master ,If value is found high then second step is to see the fault via Distance to fault location . 2.According to distance found, replace connector,Jumper ,Anteena or damaged feeder cable 3.With external test equipment check VSWR of the antenna line. Repeat step 1 if the measurement is again high

D:\userdata\alekar\ Desktop\BSS Fault

D:\userdata\alekar\ Desktop\BSS Fault