Compressors
FR10G
R134a
103G
LBP/HBP -30 to 10 LBP: 187 - 254 /50 LBP: 198 - 254 /60 HBP: 198 - 254 /50
Yellow background
DANFOSS COMPRESSORS
Motor type Max. ambient temperature Comp. cooling at ambient temp. C 32C
RSIR/CSIR 43 LBP: S HBP: F2 38C LBP: O/F1 HBP: F2 43C LBP: O/F1 HBP: F2
S O F1 F2
= Static cooling normally sufficient = Oil cooling = Fan cooling 1.5 m/s (compressor compartment temperature equal to ambient temperature) = Fan cooling 3.0 m/s necessary
16
Design
Displacement Oil quantity Maximum refrigerant charge Free gas vol. in compressor Weight without electrical equipment cm3 cm
3
204 178
19
9.05
101.6 70 60.5 35 127 150
g cm3 kg
9.7
Motor
Motor size LRA (rated after 4 sec. UL984) LST/HST Cut-in current LST/HST Resistance, main and start winding (25C) Approvals watt A A 275 10.3/10.0
C E
30
30
15.0/10.0
A B
Dimensions
Height mm A B Suction connector Process connector Discharge connector Oil cooler Compressors on a pallet location/I.D. mm location/I.D. mm location/I.D. mm location/I.D. mm pcs. C D E F 196 191 8.2 0.09
156
243 264
8266
34
102 130
127
40
40
122.5
124.5 127.5
May 2001
CD.43.O6.02
32 55
24
55
40
8285-2
25
Application
6880
watt
10 779
HST
c
Capacity (ASHRAE)
Evap. temp in C FR10G, 50Hz FR10G, 60Hz -30 113 122 -25 167 188 -23.3 188 214 -20 232 267 -15 308 361 -10 400 471 -5 510 0 639 5 791 7.2 866
watt
10 968
b
8219
Power consumption
Evap. temp in C FR10G, 50Hz FR10G, 60Hz -30 155 163 -25 179 194 -23.3 188 206 -20 205 230 -15 234 270 -10 265 314 -5 296 0 329 5 362 7.2 376
watt
10 394
d
a2
Current consumption
Evap. temp in C -30 FR10G, 50Hz 1.51 FR10G, 60Hz 1.32 -25 1.58 1.44 -23.3 1.61 1.48 -20 1.66 1.57 -15 1.75 1.73 -10 1.84 1.90 -5 1.94 0 2.05 5 2.16 7.2 2.21
A
10 2.28
10 11
12 14
13
W/W
10 1.98
Main winding Winding protector Start winding
COP (ASHRAE)
Evap. temp in C -30 FR10G, 50Hz 0.73 FR10G, 60Hz 0.75 -25 0.93 0.97 -23.3 1.00 1.04 -20 1.13 1.16 -15 1.32 1.34 -10 1.51 1.50 -5 1.72 0 1.94 5 2.19 7.2 2.30
W/W
10 2.46
LST
g
Test conditions Condensing temperature Ambient and suction gas temp. Liquid temperature 50Hz: Fan cooling F2, 220V 60Hz: Fan cooling F2, 220V
b
8217
Accessories
Devices PTC starting device Starting relay Cover Starting capacitor 80 F Cord relief Protection screen for PTC Mounting accessories Bolt joint for one compressor Bolt joint in quantities Snap-on in quantities 6.3 mm spades 4.8 mm spades Fig. a1 a2 b c d g FR10G 103N0011 103N0018 117U6010 103N2010 117U5015 103N1010 103N0476 118-1917 118-1918 118-1919
Winding protector
Danfoss can accept no responsibility for possible errors in catalogues, brochures and other printed material. Danfoss reserves the right to alter its products without notice. This also applies to products already on order provided that such alterations can be made without subsequential changes being necessary in specifications already agreed. All trademarks in this material are property of the respective companies. Danfoss and the Danfoss logotype are trademarks of Danfoss A/S. All rights reserved.
CD.43.O6.02