Vous êtes sur la page 1sur 18

Shimaden, Temperature and Humidity Control Specialists

C %RH

Series

MR13

SHIMADEN DIGITAL CONTROLLER

approved

BASIC FEATURES

3-channel controller, 3-channel input, 3-channel setting and simultaneous 3-channel display are possible Accuracy: (0.3% FS + 1 digit) Follow-up type PV input function Follow-up type SV setting function Remote/local and DI input function Programmable 1 pattern with 9-step function Included a new processing system, Expert PID, remarkably improved PID control efficiency; overshoot and undershoot are controlled effectively. Interface RS232C/RS485

MR13 SERIES 3-CHANNEL CONTROLLER


Front Panel Information
AT FLW RUN REM

Series

MR13

PV 1
COM

1 2 3
SV

PV1 display PV2 display PV3 display SV display Key switches

Action display LEDs

PV 2
OUT1 OUT2 OUT3 EV1 EV2

PV 3
EV3

CH

SV channel display
MR13

4 6

Application Example
As the controller is capable of 3-channel input and setting, it is most suitable for zone control. Control of three points is possible by a single controller using three sensors. PV values of three points are displayed simultaneously. The use for zone control such as the upper, middle and lower stages of a batch furnace and the inlet, center and outlet of a tunnel furnace, and for heat control of plastic molds, packing, machines and so forth are highly recommendable.

PAC thyristor

PAC thyristor

PAC thyristor

Follow-up Type PV Input Function

PV input of CH2 and CH3 can be linked to CH1 input. This function enables the controller to be used for 1-input 2setting or 1-input 3-setting control.
Multistage control of heating/cooling Control of heating/cooling and humidification/ dehumidification
converter MR13 T F PAC15 PAC15 Room Air conditioner Cool Room Air conditioner CH1 Heat CH2 CH3 F H H T T MR13 CH1 CH2 CH3 Heat

Follow-up Type SV Setting Function


As it is possible to make CH2 and CH3 set values follow that of CH1, SVs of these channels can be changed simply by changing CH1 setting. This function is conveniently made use of when temperature levels multiple points are changed or multiple programming functions are used.

Use of Expert PID Reduces Overshoot


Higher controllability has been attainted by the use of expert PID which can suppress hunting by overshoot or disturbance.
SV

;; ;; ; ;; ; ;;;;; ;;;;; ;
Heater Electric Furnace

TC2

TC1

TC3

Cool

PID control by new operating method (Expert PID)


Disturbance SV

Shimaden's previous PID control


Disturbance

PV

PV

ADDITIONAL FUNCTIONS (OPTIONAL)


Programming Function

Series

MR13

With the addition of the programming control function, it has become possible to carry out zone control of furnaces for china, ceramics, etc., which can be made in an ascending pattern of one pattern with nine steps maximum. * Program control of 1 pattern with 9 steps maximum

175C S5, 6 125C S7 75C S1, 2 25C S-SV

6 7

* Step execution time: 1-9999 minutes * The number of executions: 1-9999 times * Either PV start or SV start selectable * The temporary stop (HLD) function and the step forward (ADV) function are include.

STEP1 STEP2 t-1 t-2

STEP6 t-6

STEP7 t-7

* A program ramp is automatically determined by selecting the temperature and time for each step. * In the MR13, only CH1 is equipped with the programming function. In case CH2 and CH3 are used for program control, follow-up type SV should be set for each of them.

Remote and DI Input Functions


* The remote or DI input function can be added. a. DI setting allows the controller to operate in response to an external control (non-voltage contact or open collector) signal. * RUN/RST (during program control) * HLD (during program control) * ADV (during program control) b. Remote setting of an SV value by means of an external analog signal is possible as per the below drawing nos. 1and 2.

MR13 CH1 No.1 T No.2 T No.3 T CH2 CH3

REM1. REM2. REM3.

Drawing No.1

c. Simple cascade control by remote setting * When CH1 control output is made remote SV of CH2, a single MR13 controller can carry out cascade control. * Select control output (OUT) from CH1 transmission signals (SV, PV and OUT) and input it to the remote Analog out terminal of CH2 instead of inputting the control output directly to the remote SV of CH2. OUT CH1 This raises the resolution of CH1 control output so REM that control characteristics can be improved. CH2 T3
T1 T2 CH3 AL

MD

EM

CP2

EM Drawing No.2

Event Function
* Three points are available for event outputs. * Event output selected from the list of Events shown on page 6 can be assigned to EV1, EV2 and EV3.

Communication Function
For the MR13 series controllers, there are two types of communication interface, RS232C and RS485. Each allows a personal computer, etc., to set and read data of the MR13 series using signals based on EIA standards.

SPECIFICATIONS
Display LED display: Isolation: PV display 7-segment LED green 4 digits 3 channels to be displayed individually. SV display 7-segment LED orange 4 digits CH display 7-segment LED orange 1 digit Control output display: 3 - OUT1, OUT2, OUT3 Auto tuning: 1 - AT Follow type SV display: 1 - FLW Program RUN: 1 - RUN Event output display: 3 - EV1, EV2, EV3 Remote input display: 1 - REM Communication display: 1 - COM (0.3%FS + 1 digit) Standard accuracy

Series

MR13

Insulated between input and various outputs (not insulated between input and system, remote input and DI input)

Control Control mode: Proportional band (P):

Action display LED:

Integral time (I): Derivative time (D): Manual reset: ON/OFF hysteresis: Proportional cycle: Control output characteristics: Output limiter:

Expert PID control with auto tuning function OFF, 0.1~999.9%FS (OFF=ON/OFF action) OFF, 1~6000s (OFF=P, PD action with manual reset) OFF, 1~3600s (OFF=P, PI action) 50.0% 1~999 units 0.5~120.0 seconds (0.5 sec. is unit for setting.) RA/DA selectable (set to RA when shipped) Higher limit, lower limit 0.0~100.0% (lower limit < Higher limit) OFF, ON (Fixed to 10 sec.; Valid when power is turned on, RTS RUN, and when returned from scaleover.)

Display accuracy: Temperature range in which accuracy is maintained: Display resolution: Sampling cycle: Measured value display range: Setting Setting: Setting range: Higher/lower limit setting limiter:

23C5C Depends on measuring range (0.001, 0.01, 0.1, 1) 0.5 seconds 10% to 110% of measuring range

Soft start:

By 6 front key operation Same as measuring range Higher and lower limits to be set separately; free within measuring range (Lower limit < higher limit) SV of CH2 or CH3 can be set to follow CH1 (deviation setting) (on condition that measuring range of CH2 or CH3 is the same as that of CH1.)

Follow type SV setting:

Input Input type has to be the same for 3 channels (measuring range can be selected individually). Thermocouple: B, R, S, K, E, J, T, N, PL II, WRe5-26, {L, U (DIN43710)} (Multiple input, multiple range. Refer to measuring range code table.) External resistance: 100 maximum Input impedance: 500k minimum Burnout: Standard feature (up scale) Cold junction temperature compensation accuracy: 2.0 C (5~45 C) R.T.D.: JIS Pt100/JPt100 3-wire type (Multiple range. Refer to measuring range code table.) Amperage: Approx. 0.25 mA Lead wire tolerable resistance: 5 maximum/wire Voltage: 10, 0~10, 0~20, 0~50, 10~50, 0~100mV DC, or 1, 0~1, 0~2, 0~5, 1~5, 0~10V DC (Multiple input, programmable range. Refer to measuring range code table.) Input impedance: 500k minimum Current: 4~20, 0~20mA DC (Multiple input, programmable range. Refer to measuring range code table.) Receiving impedance: 250 Sampling cycle: 0.5 seconds PV bias 1999 units PV filter: OFF, 1~100 seconds Follow type PV input: PV input of CH2 or CH3 can be set to follow CH1 (deviation setting) (on condition that measuring range of CH2 or CH3 is the same as that of CH1.)

Control output/rating Output specification has to be the same for 3 channels. Contact output (Y): 1a 240V AC 2.5A/resistive load Current output (I): 4~20mA, 0~10mA DC/ load resistance 600 maximum. SSR drive voltage output (P): 15V3V DC/ Load current 20mA maximum Voltage output (V): 0~10V DC/ Load current 2mA maximum Operation output updating cycle: 0.5 second Isolation: Insulated between control output and system and input (not insulated between control output I, P or V and analog output) Event output (optional) Number of outputs:

Output rating: Setting:

Hysteresis: Standby action: Action delay time: Isolation:

3 -EV1, EV2, EV3 (Selectable from CH1, CH2 and CH3, individual setting, individual output) Contact output 1a (common) 240V AC / 1A (resistive load) Individual setting 0) NON: Not assigned 1) DEV: Higher limit deviation value alarm 2) DEV: Lower limit deviation value alarm 3) DEV: Higher/lower limit value alarm in case SV is out of measuring range 4) DEV: Higher/lower limit value alarm in case SV is within measuring range 5) PV: Higher limit absolute value alarm 6) PV: Lower limit absolute value alarm 7) SO: ON upon scaleover 8) RUN: ON during program RUN 9) END: ON for 1 sec. upon termination of program 10) STEP: ON for 1 sec. upon termination of program step 1~999 units (when DEV or PV has been selected) Selectable (when DEV or PV has been selected) OFF, 1~9999 seconds (when DEV or PV has been selected) Insulated between alarm output and various inputs/outputs and system

SPECIFICATIONS
Remote setting (optional, selectable between this function and DI) Setting signal: 1~5V, 0~10V, 4~20mA Setting range: Same as measuring range Accuracy of setting: (0.3%FS + 1) digit Channel for setting: Selectable from CH1, CH2 and CH3 Remote scaling: Within measuring range (inverted scaling possible) Remote bias: 1999~5000 units Remote filter: OFF, 1~100 seconds Sampling time: 0.5 second Isolation: Insulated between remote input and various outputs (not insulated from system and various inputs) External control input (DI) (optional, selectable between this function and remote setting) Number of input point: 1 Input rating: Non-voltage contact, open collector input (about 5V/0.4mA DC impress) Action type: NON, FLW (follow type SV), RST/ RUN, HLD and ADV Isolation: Insulated between DI input and various outputs (not insulated from system and various inputs) Program (optional) Registrable pattern: Number of steps: Program setting range Level: Time: Ramp: Number of executions: PID output limiter: External control input: Action status output: CH2 and CH3 in SV follow setting: Communication address: Communication code: Communication protocol: Communication format: Isolation: Others: 1~99 ASCII code

Series

MR13

Shimaden standard protocol Control code selectable, BCC check arithmetic system selectable Insulated between communication signal and system/input/output Meets the EMC standards with an additional clamp filter (E04SR301334, SEIWA Information Systems Co.,LTD)

Others Data storage: Ambient temperate/ humidity ranges:

By non-volatile memory (EEPROM) -10~+50C/below 90% RH (on condition that there is no dew condensation) Between-20 and +65 C 100V~260V AC 10% (50/60 Hz) 18VA maximum Normal mode 45 dB minimum (50/60 Hz) Common mode 140 dB minimum (50/60 Hz) IEC1010-1 and EN61010-1 EN61326 Between input/output terminals and power terminal: 500V DC 20M minimum Between input/output terminals and protective conductor terminal: 500V DC 20M minimum 1 minute at 2300V AC between input/output terminals and power terminal (inductive current 5mA) 1 minute at 2300V AC between power terminal and ground terminal (inductive current 5mA) Only front panel has simple dustproof and drip-proof structure PPO resin molding (equivalent to UL94V-1) 96 x 96 x 110 mm (Panel depth: 100 mm) Push-in panel (one-touch mount) H92 x W92 mm Approx. 420 g

Temperature for storage: Power voltage: Power consumption: Input noise removal ratio:

1 9 maximum Same as measuring range 1~9999 minutes/step To be set automatically according to level and time 9999 maximum To be set selectively from 3 types of PID & output limiter DI/non-voltage 1 point (RUN/RST, HLD, ADV) RUN, END and STEP to be selectively output to event output Program to be executed by making CH2 or CH3 deviation-follow to pattern set in CH1 in SV follow setting. Not in SV follow setting, program is executed in FIX mode. Temporary suspension (HLD), carryforward (ADV), PV start Applicable standard Safety: EMC: Insulation resistance:

Dielectric strength:

Protective structure: Material: External dimensions: Mounting: Panel cutout size: Weight:

Additional functions:

Analog output (optional, selectable between this function and communication) Number of output: 1 Output types: Selectable from CH1_PV, CH2_PV, CH3_PV, CH1_SV, CH2_SV, CH3_SV, CH1_OUT, CH2_OUT and CH3_OUT Output rating: 0~10mV DC/Output impedance 10 0~10V DC/Load current 1mA maximum 4~20mA DC/Load resistance 300 maximum Output accuracy: 0.3%FS (to displayed value) Output resolution: Approx. 1/8000 Output updating cycle: 0.5 seconds Output scaling: Within measuring range (inverted scaling possible) Isolation: Insulated between analog output and various inputs and system (not insulated between analog output and control outputs I, P and V) Communication (optional, selectable between this function and analog output) Communication type: RS-232C, RS-485 Communication system: Half duplex start-stop synchronous system Communication speed: 1200, 2400, 4800, 9600, 19200bps Data format: 7 bits, 8 bits, no parity, even parity selectable

ORDERING INFORMATION
ITEMS SERIES CODE MR131 2 INPUT 3 4 6 Y1I1CONTROL OUTPUT P1V1PROGRAM FUNCTION (OPTION) N P 0 EVENT OUTPUT (OPTION) 1 00 04 05 06 51 00 03 04 06 15 17 0 9

Series

MR13

REMOTE OR DI INPUT (OPTION)

ANALOG OUTPUT OR COMMUNICATION FUNCTION (OPTION)

REMARKS

SPECIFICATIONS MPU-Based 3 Channel Auto-Tuning PID Controller DIN 96 96mm Thermocouple B, R, S, K, E, J, T, N, PLII, Multi-input WRe5-26, U, L Multi-range R.T.D. Pt100 / JPt100 Multi-range Voltage (mV) -10-10, 0-10, 0-20, 0-50, 10-50, Multi-input 0-100mV DC Programmable Current (mA) 0-20, 4-20mA DC Range Voltage (V) -1-1, 0-1, 0-2, 0-5, 1-5, 0-10V DC Contact: Proportional Cycle 0.5-120.0 sec. Contact capacity: 240V AC 2.5A / resistive load Current: 4-20, 0-10mA DC Load resistance: 600 max. SSR drive voltage: Proportional Cycle 0.5-120.0 sec. Output rating: 15V3V DC / 20mA max. Voltage: 0-10V DC Load current: 2mA max. None 1 Pattern, 9 step None Contact (1a common): 240V AC 1A / resistive load EV1, EV2, EV3 / 3 Point None 4-20mA DC Receiving resistance: 250 1-5V DC Input resistance: 500k min. 0-10V DC Input resistance: 500k min. DI Non-Voltage Contact, Open Collector Input None Voltage 0-10mV DC, Output resistance: 10 Current 4-20mA DC, Load resistance: 300 max. Voltage 0-10V DC, Load current: 1mA max. RS-485 RS-232C Without With (Please consult before ordering.)

TYPES OF EVENTS
Event type code table
Code OFF 1 2 3 4 5 Event type Not assigned Higher limit deviation value Lower limit deviation value Out of higher/ lower limit ranges Within higher/ lower limit ranges Higher limit absolute value Lower limit absolute value 0~1999 Unit 0~1999 Unit 0~1999 Unit 0~1999 Unit 1999 Unit 8 1999 Unit 9 1999 Unit 10 1999 Unit Setting range of event set value Initial value of event set value Code 7 Event type Scale-over Program RUN Program END Program STEP Setting range of Initial value of event set value event set value In the case of scale-over, EV output is continued. EV output is continued while program is in execution. EV output is produced for about 1 second upon termination of program. EV output is produced for about 1 second upon switching steps.

Within measuring Higher limit value range of measuring range Within measuring Lower limit value range of measuring range

Note: The above codes from 8 to 10 are selectable only when program option is added.

MEASURING RANGE CODES


Input type *1 B R S Code Measuring range 01 1800 C 0 02 1700 C 0 03 1700 C 0 04 -100.0 400.0 C K 0.0 05 800.0 C 0 06 1200 C E 0 07 700 C J 0 08 600 C 09 -199.9 200.0 C *2 T N 0 10 1300 C PLII 0 11 1300 C WRe5-26 12 0 2300 C *2 U 13 -199.9 200.0 C L 0 14 600 C 31 -200 600 C 32 -100.0 100.0 C 33 -100.0 300.0 C Pt100 34 -50.0 50.0 C (New) 35 *3 0.0 50.0 C JIS/IEC 36 0.0 100.0 C 37 0.0 200.0 C 38 0.0 500.0 C -200 39 500 C 40 -100.0 100.0 C 41 -100.0 300.0 C JPt100 50.0 C 42 -50.0 (Old) JIS 43 *3 0.0 50.0 C 0.0 44 100.0 C 0.0 45 200.0 C 0.0 46 500.0 C Code 15 16 17 18 19 20 21 22 23 24 25 26 27 28 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 Measuring range 3300 F 0 3100 F 0 3100 F 0 -150 750 F 0 1500 F 0 2200 F 0 1300 F 0 1100 F -300 400 F 0 2300 F 0 2300 F 0 4200 F 400 F -300 0 1100 F -300 1100 F -150.0 200.0 F -150 600 F -50.0 120.0 F 0.0 120.0 F 0.0 200.0 F 0.0 400.0 F 1000 F 0 -300 900 F -150.0 200.0 F -150 600 F -50.0 120.0 F 0.0 120.0 F 0.0 200.0 F 0.0 400.0 F 0 900 F

Series

MR13

Code Input type Measuring range mV -10 10 71 10 72 Depending on scaling function, you may 0 20 73 set measuring range at any value within 0 50 74 the following range: 0 Scaling range: 1999~9999 count 50 75 10 Span: 10~5000 count 0 100 76 Note: Lower limit value < Higher limit 81 value V -1 1 82 1 0 83 2 0 84 5 0 85 5 1 86 10 0 94 20 mA 0 95 4 20 *1 Thermocouple B: Temperature above 400C or below 750 F is excluded from accuracy assurance. *2 Thermocouple T, U: Accuracy of temperature between -199.9 and 100.0C is 0.5% FS. *3 R.T.D.: Accuracy is 0.3C (0.8 F).

R.T.D.

Thermocouple

The following table shows factory-set measuring range codes: Standard/ rating JIS K JIS Pt100 0 10mV DC 4 20mA DC 0 10V DC Measuring range 0.0 800.0C 0.0 200.0C 0.0 100.0 0.0 100.0 0.0 100.0

Input 1. Thermocouple 2. R.T.D. 3. Voltage 4. Current 5. Voltage

Code 05 37 72 95 86

EXTERNAL DIMENSIONS
110 100

96
AT FLW RUN OUT 1 EV 1 OUT 2 EV 2 OUT 3 EV 3 REM COM

10

PV 1

PV 2

PV 3

CH

SV

DISP
MR13

CH

ENT

96

Panel Cutout

91.6
1 21 31 11

130 min
+0.8 0

22

32

12

23

33

13

24

34

14

130 min

91.6

25

35

15

26

36

16

92

+0.8 0

27

37

17

28

38

18

29

39

19

10

30

40

20

(Unit : mm)

92

TERMINAL ARRANGEMENT
INPUT I.V. Input TC Input RTD Input Analog Out Com A-output RS-232C RS-485 REM DI
11 12

Series

MR13

Power Supply

+
+
2

21

21

2 3 4

23 24

SG SD RD

23 24 25

SG

23 24 25

100-260V AC~ 50/60Hz 18VA

22

22 13

GND

Control Output
6

1
7

1 2 3 4 5

21 22 23 24 25 26 27 28 29 30

21 22 23 24 25

31 32 33 34 35

11 12 13 14 15

11 12 13 14 15 16 17 18 19 20

Contact Output CH1


15 16

I. V. Output SSR. drive.V Output

2
+
8

8 9 10

3 4 5 6 7

15 16

10

10

CH2
17 18

6 7

26 27

36 37

16 17

17 18

Event Output

8
COM EV1 EV2 EV3 27 28 29 30

8 9 10

28 29 30

38 39 40

18 19 20

CH3
19 20

9 10

19 20

TERMINAL COVER (AVAILABLE SEPARATELY)


Model MR13 SR5301-9 Mounting: 2+B tight pan-head screws M2.3x6mm

Material/ Appearance: PVC/ transparent Thickness: 1mm

Warning The MR13 series is designed for the control of temperature, humidity and other physical values of general industrial equipment. (It is not to be used for any purpose which regulates the prevention of serious effects on human life or safety.) Caution If the possibility of loss or damage to your system or property as a result of failure of any part of the process exists, proper safety measures must be made before the instrument is put into use so as to prevent the occurrence of trouble.

ISO 9001
(The contents of this brochure are subject to change without notice.)

Temperature and Humidity Control Specialists

Head Office: 2-30-10 Kitamachi, Nerima-Ku, Tokyo 179-0081 Japan Phone: +81-3-3931-7891 Fax: +81-3-3931-3089 E-MAIL: exp-dept@shimaden.co.jp URL: http://www.shimaden.co.jp

00IMR13 1030

Shimaden, Temperature and Humidity Control Specialists

C C %RH %RH

SHIMADEN DIGITAL CONTROLLER SHIMADEN DIGITAL CONTROLLER

Series SR1 / SR3 / SR4 Series SR1 / SR3

BASIC FEATURES
Multi-input and multi-range performance Large 20mm bright display (SR3) Dust and splash proof front panel

NEMA4X / IP66

approved

UL approved (except SR4)


SPECIFICATIONS
MPU-Based Auto-Tuning PID Digital Controller, DIN H48 x W48 x D111mm MPU-Based Auto-Tuning PID Digital Controller, DIN H96 x W96 x D111mm MPU-Based Auto-Tuning PID Digital Controller, DIN H96 x W48 x D111mm Thermocouple: B, R, S, K, E, J, T, N, PLII, WRe5-26 {U, L (DIN 43710)} R.T.D.: Pt100/JPt100 -10~10, 0~10, 0~20, Voltage(mV): 0~50, 10~50, 0~100mV DC Scaling

ORDERING INFORMATION
ITEM SERIES SR1 SR3 SR4 8 Multi input INPUT 6 Y I P V
CODE

possible 10~5000

Voltage (V): -1~1, 0~1, 0~2, 0~5, 1~5, 0~10V DC 0~20mA DC:(V) 0~5V DC Current (mA): 4~20mA DC:(V) 1~5V DC (applied via enclosed 250 shunt resistor)

Range: -1999~9999 Span:

CONTROL OUTPUT EVENT OUTPUT REMARKS

Contact 1a Contact capacity: 240V AC 2.0A/resistive load Proportional cycle: 1~120 seconds Current 4~20mA DC Load Resistance: 600 max. SSR drive voltage 12V 1.5V DC 30mA max. Proportional cycle:1~120 seconds Voltage 0~10V DC Load current: 2mA max. 1 Event output (1a) x 2 points, Contact capacity: 240V AC 1A/resistive load W Without X With (Please consult before ordering.)

MEASURING RANGE CODES


Type of input B *1 R S *3 K Code 01 02 03 04 05 06 E 07 J 08 T *3 09 N 10 PLII *4 11 WRe5-26*5 12 U *2, *3 13 L *2 14 31 32 Pt100 33 34 35 36 JPt100 37 38 0 0 0 199.9 0.0 0 0 0 199.9 0 0 0 199.9 0 200 100.0 50.0 0.0 200 100.0 50.0 0.0 Scaling range 1800 C 0 1700 C 0 1700 C 0 400.0 C 300 0 800.0 C 0 1200 C 0 700 C 0 600 C 200.0 C 300 0 1300 C 0 1300 C 0 2300 C 200.0 C 300 0 600 C 600 C 300 100.0 C 150.0 50.0 C 50.0 0.0 200.0 C 500 C 300 100.0 C 150.0 50.0 C 50.0 0.0 200.0 C 3300 F 3100 F 3100 F 750 F 1500 F 2200 F 1300 F 1100 F 400 F 2300 F 2300 F 4200 F 400 F 1100 F 1100 F 200.0 F 120.0 F 400.0 F 1000 F 200.0 F 120.0 F 400.0 F Scaling range Type of input Code 71 10 10 Optional setting of Measuring range is 72 0 10 possible by the scaling function as 73 0 20 shown below. 74 0 50 (mV) 10 75 50 Scaling range: 1999~9999 count 76 0 100 Span: 10~5000 count 1 81 1 Lower limit value < Upper limit value 82 0 1 Position of decimal point : None 83 0 2 : Decimal point below digits, 1, 2, 3 84 0 5 (V) 85 1 5 86 0 10
Note:*1 Thermocouple B: Accuracy guarantee not applicable Temp. below 400 C. *2 Thermocouple U, L: DIN 43710 *3 Thermocouple K, T, U: Accuracy guarantee not applicable Temp. below 100.0C (1.0%FS+1digit) & 100.0 0.0C (0.5%FS+1digit) *4 Thermocouple PLII: Platinel *5 Thermocouple WRe5-26: ASTM988 *Unless otherwise specified, following setting will be applied for shipment.
Input Multi input Voltage (V)
Control Output Y I, P, V

Thermocouple

R.T.D.

Voltage

Voltage

Specification/Rating K thermocouple 0 10V DC


Control Mode ON-OFF (P=OFF) PID Control (P=3.0)

Measuring range 0.0 800.0 C 0.0 100.0

SPECIFICATIONS
Model 48 x 48 Digital Controller SR1: 96 x 96 Digital Controller SR3: 96 x 48 Digital Controller SR4: Display Digital display:SR1, SR4:(PV)/4 digit 7 segments red LED (H: 11mm) (SV)/4 digit 7 segments green LED (H: 9.5mm) (PV)/4 digit 7 segments red LED (H: 20mm) SR3: (SV)/4 digit 7 segments green LED (H: 13mm) (0.3%FS + 1 digit) (see "Note" in Measuring Range Codes) Display accuracy: (Excluding cold junction compensation accuracy) Display accuracy maintaining range: 23C 5C Depends on measuring range (0.001, 0.01, 0.1, 1) Display resolution: Display updating cycle: 0.5 seconds 5 LED lamp displays (OUT/EV1/EV2/AT/MAN) Action display: Setting By operating 4 keys ( , , ENT , )(front panel) Setting method: Target value setting range: Same as measuring range (within setting limitter) Individual setting for higher & lower limits are possible Setting limiter: within measuring range (Lower limit value < Higher limit value) Input Selectable from multiple (TC,Pt,mV) and voltage (V) Type of input: *Current input 0-20mA DC (Voltage: 0-5V), 4-20mA DC (Voltage: 1-5V) applied via 250 shunt resistor B,R,S,K,E,J,T,N,PL II,WRe5-26, {U,L(DIN 43710)} Thermocouple: 500k minimum Input impedance: External resistance tolerance: 100 maximum Standard feature (up scale) Burnout function: Cold junction compensation accuracy: 1C (within 23C 5C) 2C (ambient temperature: 5C to 45C) Pt100/JPt100, 3-wire type R.T.D.: 0.25 mA Amperage: Lead wire tolerance:5 max/wire Lead wire tolerance: (3 lead wires should have the same resistance.) -10~10,0~10,0~20,0~50,10~50, 0~100mv DC Voltage mV: (Burnout) Up scale at time of abnormal input -1~1, 0~1, 0~2, 0~5,1~5, 0~10V DC V: 500k minimum Input impedance: Input scaling function: Scaling possible for voltage (mV,V) or current (mA) input -1999~9999 counts Scaling range: 10~5000 counts Span: (Position) None, 0.0, 0.00, 0.000 Decimal point: 0.5 seconds Sampling cycle: -1999~2000 units PV bias: 0~100 seconds PV filter: Insulated between input and output (not insulated Isolation: between input and system) Control Expert PID control with auto tuning function Control mode: OFF, 0.1~999.9%(ON-OFF action by OFF) Proportional band (P): OFF, 1~6000 seconds (P or PD action by OFF) Integral time (I): OFF, 1~3600 seconds (P or PI action by OFF) Derivative time (D): -50.0~50.0% (Effective when I=OFF) Manual reset: 1~999 units (Effective when P=OFF) ON-OFF hysteresis: 1~120 seconds (for contact and SSR drive voltage output) Proportional cycle:

Series SR1

/ SR3 / SR4

Control output characteristic: RA (reverse action characteristic)/DA (direct action characteristic) is selectable (Default setting =RA) *P=OFF by default for contact output, others: PID control Type of control/rating: 1a 240V AC 2A (resistive load) Contact: 12V 1.5V DC (Max load current 30mA) SSR drive voltage: 0~10V DC (Max load current 2mA) Voltage: 4~20mA DC (Max load resistance 600) Current: Control output resolution: Approx.0.5%(1/200) Output isolated from all Isolation: Event output Total 2 points of EV1 and EV2 as standard Number of events: Selectable from the following 8 types for EV1 and EV2: Type: No selection, Higher limit deviation, Lower limit deviation, Outside higher/lower limit deviations, Within higher/lower limit deviations, Higher limit absolute value, Lower limit absolute value, Scaleover Absolute values: (both higher limit and lower limit): Within Event setting range: measuring range, Deviations: (both higher limit and lower limit): -1999~2000 units, Higher/lower limit deviations (within/outside): 0~2000 units ON-OFF action Event action: 1~999 units Hysteresis: Selectable from the following 4 types Standby action: (1) None. (2) Standby when power is applied. (3) Standby (EV1 and EV2) when power is applied and when SV value in execution is changed. (4) Control mode without standby action (No alarm is output at the time of abnormal input). Contact (1a x 2 points common)/240V AC 1A (resistive load) Output type/rating: Output updating cycle: 0.5 seconds 2 LED lamp displays (EV1/EV2) Action display: General Specifications Non-volatile memory (EEPROM) Data storage: Operating conditions: (Ambient temperature) -10~50 C (Ambient humidity) 90%RH or less (no dew condensation) (Altitude) 2000m from the sea level or lower (Category) II, (Degree of pollution) 2 Storage temperature: -20~65C 100-240V AC10% 50/60Hz Supply voltage: 10VA 240V AC, 6VA 100V AC Power consumption: (Normal mode) 40 dB or higher (50/60 Hz) Input/noise (Common mode)120 dB or higher (50/60 Hz) removal ratio: For Voltage (V) input: 90 dB or higher (50/60 Hz) Applicable standards: Safety: IEC61010 and EN61010-1 EMC: EN61326 (Class A: Industrial environment) Insulation resistance: Input/output - power supply: 500V DC 20M or above Input/output - contact output: 500V DC 20M or above Input/output - power supply: 2300V AC 1 minute Dielectric strength: Contact output - power supply: 2300V AC 1 minute Only front panel has dust-proof and drip-proof structure Protective structure: NEMA4X and IP66
Material / Color of case: PPO resin molding (equivalent to UL94V-1) / Ivory

External dimensions: Mounting: Panel thickness: Panel cutout / Weight:

SR1: H48 x W48 x D111 (Panel depth: 100) mm SR3: H96 x W96 x D111 (Panel depth: 100) mm SR4: H96 x W48 x D111 (Panel depth: 100) mm Push-in panel (one-touch mount) 1.0~4.0 mm SR1: H45 x W45 mm / Approx. 150 g SR3: H92 x W92 mm / Approx. 270 g SR4: H92 x W45 mm / Approx. 190 g

External Dimensions & Panel Cutout

Terminal Arrangement

SR1
48
PV SV

11

111
100

SR4
45 44.6
+0.6 0

SR1
111
100

SR3 / SR4
L

48 45 +0.6 0
PV SV

11

45 +0.6 0
100-240VAC 50/60Hz 10VA

1 2

I .

48

OUT

EV1

EV2

AT

MUN

SR 1

OUT

96

ENT

EV1

EV2

AT

MAN

SR3
96
PV

ENT

11

111
100

SR 4

92

+0.8 0

OUTPUT 4-20mA DC 1 + 0-10V DC 30mA12V DC 2A240V AC 2 + +A 3


B

I . 6
L

7 N 8 9 10

100-240V AC 50/60Hz10VA COM EV1 1A240V AC EV2 1A240V AC

OUTPUT 4-20mA DC 3 + 0-10V DC 30mA12VDC 2A240V AC 4 5 COM EV1 1A240V AC 6 EV2 1A240V AC 7 + + A 8 9 10

92 +0.8 0

91.6

DC

OUT

EV1

EV2

AT

MAN

ENT

96

SV

92 +0.8 0

91.6

B 5

Unit: mm
Model SR1 SR3 SR4 Terminal Cover (P/N) QCR001 QCR006 QCR004 (Individual Mounting) QCR005 (Tight-lock coupling)

DC

B B

SR 3

TERMINAL COVER (AVAILABLE SEPARATELY)


Material:PVC, Appearance:transparent, Thickness: 1 mm

Mounting One-touch mount One-touch mount


Plus screw, B tight, M2.3 x 6 - 2 pcs. Plus screw, B tight, M2.3 x 6 - 4 pcs.

Warning The SR1 / SR3 / SR4 series are designed for the control of temperature, humidity and other physical values for the general industrialequipment. It is not to be used for
any purpose which regulates the prevention of serious effects on human life or safety. No warranty, express or implied is valid if used without proper safety measures. If the possibility damage to your Caution instrument is putof loss or as to prevent thesystem or property as a result of failure of any part of the process exists, proper safety measures must be made before the into use occurrence of trouble. (The contents of this brochure are subject to change without notice.)

Temperature and Humidity Control Specialists

ISO 9001

ISO 14001

Head Office: 2-30-10 Kitamachi, Nerima-Ku, Tokyo 179-0081 Japan Phone: +81-3-3931-7891 Fax: +81-3-3931-3089 E-MAIL: exp-dept@shimaden.co.jp URL: http://www.shimaden.co.jp

Shimaden, Temperature and Humidity Control Specialists

C %RH

Series SR90

SHIMADEN DIGITAL CONTROLLER

BASIC FEATURES

Multi-input and multi-range performance Large 20mm bright display (SR93) Readable from a distance and in a low light area 2-output heating and cooling control available RS232C or RS485 Interface available Dust and splash proof front panel equivalent to IP66 A wide selection of additional functions (optional) is available to suit various needs.

SPECIFICATIONS
Measured value (PV)/7 segments red LED 4 digits Target set value (SV)/7 segments green LED 4 digits Display accuracy: (0.3%FS + 1 digit) Excluding reference contact temperature compensation accuracy of thermocouple input. Accuracy of readings lower than 100C of thermocouples K, T, U inputs is 0.7%FS. Accuracy guarantee not applicable to 400C (752F) and below of B thermocouple. Display accuracy maintaining range: 23C 5C (18~28C) Display resolution: Depends on measuring range (0.001, 0.01, 0.1 and 1) Measured value display range: 10%~110% of measuring range Display updating cycle: 0.25 seconds Action display/color: 7 type, LED lamp display Control output (OUT1, OUT2)/Green Event (EV1, EV2)/Orange Auto tuning/Green Manual control output (MAN)/Green Set value bias, communication (SB/COM)/Green Setting Setting method: By operating 4 keys ( , , and E N T ) on the front panel Target value setting range: Same as measuring range (within setting limiter) Setting limiter: Individual setting for higher and lower limits, any value is selectable within measuring range (Lower limit value<Higher limit value) Input Type of input: Selectable from multiple (TC, Pt, mV), voltage (V) and current (mA) Thermocouple: B, R, S, K, E, J, T, N, PL II, Wre5-26 {U, L (DIN 43710)} Input impedance: 500k minimum External resistance tolerance: 100 maximum Burnout function: Standard feature (up scale) Reference junction compensation accuracy: 1C (within the accuracy maintaining range (23 5C)) 2C (between 5 and 45C of ambient temperature) R.T.D.: Pt100/JPt100, 3-wire type Normal current: 0.25 mA Lead wire tolerance: 5 maximum/wire (3 lead wires should have the same resistance.) Voltage mV: 10~10, 0~10, 0~20, 0~50, 10~50, 0~100mv DC V: 1~1, 0~1, 0~2, 0~5, 1~5, 0~10V Input impedance: 500k minimum Current mA: 0~20, 4~20mA DC Receiving impedance: 250 Input scaling function: Scaling possible for voltage (mV, V) or current (mA) input Scaling range: 1999~9999 counts Span: 10~5000 counts Position of decimal point: None, 1, 2 and 3 digits on the right of decimal point Sampling cycle: 0.25 seconds PV bias: 1999~2000 units PV filter: 0~100 seconds Isolation: Control input not insulated from system, set value bias, and CT input but insulated from others Control Control mode With 1 output: Expert PID control with auto tuning function RA (reverse action characteristic): Heating action DA (direct action characteristic): Cooling action With 2 outputs: Expert PID control with auto tuning function + PID control PID (output 1) + PID (output 2) Display Digital display:

Series SR90
RA (reverse action characteristic): Heating action (OUT1) and cooling action (OUT2) DA (direct characteristic): 2-stage heating action Type of control/rating: Contact/1a 240V AC 2A (resistive load) 1.2A (inductive load) (Common to Output 1 and 2): SSR drive voltage/12V1.5V DC (Maximum load current 30mA) Current/4~20mA DC (Maximum load resistance 600) Voltage/0~10V DC (Maximum load current 2mA) Control output resolution: Control output 1: approx. 0.0125% (1/8000) Control output 2: approx. 0.5% (1/200) Control output 1 Proportional band (P): OFF, 0.1~999.9% (ON-OFF action by OFF) Integral time (I): OFF, 1~6000 seconds (P or PD action by OFF) Derivative time (D): OFF, 1~3600 seconds (P or PI action by OFF) Set value function: OFF, 0.01~1.00 ON-OFF hysteresis: 1~999 units (Effective when P=OFF) Manual reset: 50.0~50.0% (Effective when I=OFF) Higher/lower limit output limiter: Lower limit 0.0~99.9%, higher limit 0.1~100.0% (Lower limit value < Higher limit value) Proportional cycle: 1~120 seconds (for contact and SSR drive voltage output) Control output 2 (option) Proportional band (P): OFF, 0.1~999.9% (ON-OFF action by OFF) Integral time (I): OFF, 1~6000 seconds (P or PD action by OFF) Derivative time (D): OFF, 1~3600 seconds (P or PI action by OFF) Set value function: OFF, 0.01~1.00 ON-OFF hysteresis: 1~999 units (Effective when P=OFF) Dead band: 1999~5000 units (Overlap with a negative value) Higher/lower limit output limiter: Lower limit 0.0~99.9%, higher limit 0.1~100.0% (Lower limit value < Higher limit value) Proportional cycle: 1~120 seconds (for contact and SSR drive voltage output) Manual control Output setting range: 0.0~100.0% Setting resolution: 0.1% Manual auto switching: Balanceless bumpless (within proportional range) Soft start: OFF, 1~100 seconds AT point: SV value in execution Control output characteristic: RA (reverse action characteristic)/DA (direct action characteristic) switching by front key or communication With 2 outputs: RA (heating/cooling)/DA (2 stage heating) Isolation: Contact output isolated from all. Analog output not insulated from SSR drive voltage, current and voltage but insulated from others. (In case another output is also SSR drive voltage, current or voltage, two outputs are not insulated from each other.) Event output (option) Number of event points: 2 points of EV1 and EV2 Types: Selectable from the following 9 types for EV1 and EV2: : No selection : H igher limit deviation : Lower limit deviation : Outside higher/lower limit deviations : W ithin higher/lower limit deviations : H igher limit absolute value : Lower limit absolute value : Scaleover : Heater break/loop alarm Event setting range: Absolute values (both higher limit and lower limit): Within measuring range Deviations (both higher limit and lower limit): 1999~2000 units Higher/lower limit deviations (within/outside): 0~2000 units

Series SR90
ON-OFF action 1~999 units Selectable from the following 4 types 1 Without standby action. 2 Standby when power is applied. 3 Standby when power is applied and when SV value in execution is changed. 4 Control mode without standby action (No alarm is output at the time of abnormal input). Output type/rating: Contact (1a 2 points common)/240V AC 1A (resistive load) Output updating cycle: 0.25 seconds Heater break/heater loop alarm (option) Break/loop detection only for OUT1 (Selectable when output type is contact or SSR drive voltage) Current capacity: 30A, 50A to be designated when CT is ordered. Alarm action: Heater current is detected by external CT provided as an accessory. When heater break is detected while control output is ON=Alarm output ON When heater loop alarm is detected while control output is OFF=Alarm output ON Current setting range: OFF, 0.1~50.0A (Alarm action is stopped by setting OFF) Setting resolution: 0.1A Current display range: 0.0~55.0A Display accuracy: 2.0A (Sine wave at 50Hz) Minimum time to identify action: 0.25 seconds (every 0.5 seconds) common to ON and OFF Alarm retention mode: Selectable from lock (to retain) and real (not to retain). Standby action: Selectable from without (OFF) and with (ON). Sampling cycle: 0.5 seconds Isolation: CT input not insulated from system and other inputs but insulated from the others. Set value bias (option) Setting range: 1999~5000 units Action input: Non-voltage contact or open collector (level action) about 5V DC, 1mA maximum Minimum level retention time: 0.15 seconds Isolation: Action input not insulated from system and other inputs but insulated from others Communication function (option) Type of communication: RS-232C, RS-485 Communication system: RS-232C 3-line type half duplex system RS-485 2-line type half duplex system {RS-485 is of half-duplex multi-drop (bus) system} Synchronization system: Start-stop synchronization system Communication distance: RS-232C The longest: 15 m RS-485 The longest 500 m (depending on conditions) Communication speed: 1200, 2400, 4800, 9600, 19200 bps Data format: 7 bits, even parity, 1 stop bit or 8 bits, non-parity, 1 stop bit Communication address: 1~255 Communication memory mode: EEP/RAM/r_E Communication BCC: Add/Add two's cmp/XOR/None Communication delay time: 1~100 ( 0.512 msec) Communication code: ASCII code Communication protocol: Shimaden's standard protocol Number of connectable instruments: RS-232 1 RS-485 up to 31 Isolation: Communication signals insulated from system, each input and each output. Event action: Hysteresis: Standby action: EV1 and EV2: Analog output (option) Number of output points: 1 point Type of analog output: Selectable from measured value, target value (SV in execution), control output 1 and control output 2. Output signal/rating: 4~20mA DC/Maximum load resistance 300 0~10V DC/Maximum load current 2mA 0~10mV DC/Output resistance 10 Output scaling: Measured value, target value: Within measuring range (inversed scaling possible) Control output 1 and 2 0.0~100.0% (inversed scaling possible) Output accuracy: 0.3% FS (with respect to displayed value) Output resolution: Approx. 0.01% (1/10000) Output updating cycle: 0.25 seconds Isolation: Analog output insulated from system and inputs but not insulated from control output except contact output. General specifications Data storage: Non-volatile memory (EEPROM) Environmental conditions for instrument operation: Temperature: 10~50C Humidity: 90% RH or less (no dew condensation) Height: 2000m from the sea level or lower Category: II Degree of pollution: 2 Storage temperature: 20~65C Supply voltage: Either 100-240V AC10% 50/60Hz or 24V AC/DC10% to be designated. Power consumption: SR91: 100-240VAC 11VA maximum for AC; 6W for DC 24V; 7VA for AC 24V SR92, SR93 and SR94: 100-240VAC 15VA maximum for AC; 8W for DC 24V; 9VA for AC 24V Input/noise removal ratio: 50 dB or higher in normal mode (50/60 Hz) 130 dB or higher in common mode (50/60 Hz) Applicable standards: Safety: IEC1010 and EN61010-1 EMC: EN61326 Insulation resistance: Between input/output terminals and power terminal 500V DC 20M or above; Between input/output terminals and protective conductor terminal 500V DC 20M or above Dielectric strength: Between input/output terminals and power terminal 2300V AC/minute; Between power terminal and protective conductor terminal 1500V AC/minute Protective structure: Only front panel has dust-proof and dripproof structure equivalent to IP66. Material of case: PPO resin molding (equivalent to UL94V-1) External dimensions: SR91: H48 W48 D111 (Panel depth: 100) mm SR92: H72 W72 D111 (Panel depth: 100) mm SR93: H96 W96 D111 (Panel depth: 100) mm SR94: H96 W48 D111 (Panel depth: 100) mm Mounting: Push-in panel (one-touch mount) Panel thickness: 1.0~4.0 mm Panel cutout: SR91: H45 W45 mm SR92: H68 W68 mm SR93: H92 W92 mm SR94: H92 W45 mm Weight: SR91: Approximately 170 g SR92: Approximately 280 g SR93: Approximately 330 g SR94: Approximately 240 g

Series SR90

ITEM SERIES

CODE SR91-

8 INPUT 4 6 YICONTROL OUTPUT (1) PVPOWER SUPPLY EVENT OUTPUT (OPTION)

Multi input

SPECIFICATIONS MPU-Based Auto-Tuning PID Digital Controller, DIN H48 W48 D110mm Thermocouple: B, R, S, K, E, J, T, N, PLII, Wre5-26 {U, L (DIN 43710)} R.T.D.: Pt100 /JPt100 Voltage: -10~10, 0~10, 0~20, 0~50, For voltage and current input: 10~50, 0~100mV DC Scaling Possible Range: -1999~9999 Current (mA): 0~20, 4~20mA DC Span: 10~5000 Receiving impedance: 250 Note: Inverse scaling Voltage (V): -1~1, 0~1, 0~2, 0~5, is not possible 1~5, 0~10V DC Contact: 1a, Contact capacity: 240V AC 2.5A/resistive load Proportional cycle: 1~120 sec. Current: 4~20mA DC Load resistance: 600 max. SSR drive voltage: 12V 1.5V DC/30mA max. Proportional cycle: 1~120 sec. Voltage: 0~10V DC Load current: 2mA max. 100~240V AC 10%, 50/60Hz 24V AC/DC 10%, 50/60Hz None Contact output (2a) Ev1, Ev2: 240V AC 1A/resistive load None Contact: 1a, Contact capacity: 240V AC 2.5A/resistive load Proportional cycle: 1~120 sec. Current: 4~20mA DC Load resistance: 600 max. SSR drive voltage: 12 1.5V DC/30mA max. Proportional cycle: 1~120 sec. Voltage: 0~10V DC Load current: 2mA max. Current setting range: 0.1~30.0A (with CT 30A) Current setting range: 0.1~50.0A (with CT 50A) Voltage: 0~10mV DC, Output resistance: 10 Current: 4~20mA DC, Load resistance: 300 max. Voltage: 0~10V DC, Load current: 2mA max. RS-485 1 point (setting range: -1999~5000), Non-voltage contact or Open collector input Open collector input rating: approx. 5V/1mA max. Without With (Please consult before ordering.) Note: Avaialble only when control output (1) is Y or P and when event output is selected.

90080 1 N Y I Control output (2) P V 1 Heater break alarm 2 3 Analog output Communication Set value bias 4 6 5 8 0 9

OPTION

REMARKS

Note: When you purchase a two-output type controller and use it in a one output capacity, larger overshooting or undershooting may happen as a result of integral operation. Therefore, we recommend you to choose a one-output type. The cause of the above-mentioned problem is that the positional relationship between the proportional band (PB) and the set value (SV) of a one-output type controller differs from that of a two-output type.

Series SR90
ITEM SERIES CODE SR92SPECIFICATIONS MPU-Based Auto-Tuning PID Digital Controller, DIN H72 W72 D110mm Thermocouple: B, R, S, K, E, J, T, N, PLII, Wre5-26 {U, L (DIN 43710)} R.T.D.: Pt100 /JPt100 Voltage (mV): -10~10, 0~10, 0~20, For voltage and current input: 0~50, 10~50, 0~100mV DC Scaling Possible Current (mA): 0~20, 4~20mA DC Range: -1999~9999 Receiving impedance: 250 Span: 10~5000 Voltage (V): -1~1, 0~1, 0~2, 0~5, 1~5, Note: Inverse scaling is not possible. 0~10V DC Input resistance: 500k min. Contact: 1a, Contact capacity: 240V AC 2A/resistive load Proportional cycle: 1~120 sec. Current: 4~20mA DC Load resistance: 600 max. SSR drive voltage: 12V1.5V DC/30mA max. Proportional cycle: 1~120 sec. Voltage: 0~10V DC Load current: 2mA max. None Contact: 1a, Contact capacity: 240V AC 2A/resistive load Proportional cycle: 1~120 sec. Current: 4~20mA DC Load resistance: 600 max. (RA when shipped) SSR drive voltage: 12V1.5V DC/30mA max. Proportional cycle: 1~120 sec. Voltage: 0~10V DC Load current: 2mA max. 100V~240V AC10%, 50/60Hz 24V AC/DC10%, 50/60Hz None Event output (2a) Ev1, Ev2 Contact capacity: 240V AC 1A/resistive load Note: Available only Event output (Ev1) + Heater break alarm (with CT30A) when control output (1) is Y or P is selected. Event output (Ev1) + Heater break alarm (with CT50A) 0 3 4 6 0 5 7 8 REMARKS 0 9 None Voltage: 0~10mV DC, Output resistance: 10 Current: 4~20mA DC, Load resistance: 300 max. Voltage: 0~10V DC, Load current: 2mA max. None RS-485 RS-232C 1 point (setting range: -1999~5000), Non-voltage contact or Open collector input Open collector input rating: approx. 5V/1mA max. Without With (Please consult before ordering.)

8 INPUT 4 6

Multi input

YICONTROL OUTPUT (1) PVNYCONTROL OUTPUT (2) (OPTION) IPVPOWER SUPPLY 90080 1 EVENT OUTPUT/ HEATER BREAK ALARM (OPTION) 2 3

ANALOG OUTPUT (OPTION)

COMMUNICATION OR SV BIAS (OPTION)

Note: When you purchase a two-output type controller and use it in a one output capacity, larger overshooting or undershooting may happen as a result of integral operation. Therefore, we recommend you to choose a one-output type. The cause of the above-mentioned problem is that the positional relationship between the proportional band (PB) and the set value (SV) of a one-output type controller differs from that of a two-output type.

Series SR90
ITEM SERIES SR93SR94CODE SPECIFICATIONS MPU-Based Auto-Tuning PID Digital Controller, DIN H96 W96 D110mm MPU-Based Auto-Tuning PID Digital Controller, DIN H96 W48 D110mm Thermocouple: B, R, S, K, E, J, T, N, PLII, Wre5-26 {U, L (DIN 43710)} R.T.D.: Pt100 /JPt100 Voltage: -10~10, 0~10, 0~20, For voltage and current input: 0~50, 10~50, 0~100mV DC Scaling Possible Current (mA): 0~20, 4~20mA DC Range: -1999~9999 Receiving impedance: 250 Span: 10~5000 Voltage (V): -1~1, 0~1, 0~2, 0~5, 0~10V DC Note: Inverse scaling Load resistance: 600 max. is not possible Contact: 1a, Contact capacity: 240V AC 2A/resistive load Proportional cycle: 1~120 sec. Current: 4~20mA DC Load resistance: 600 max. SSR drive voltage: 12V1.5V DC/30mA max. Proportional cycle: 1~120 sec. Voltage: 0~10V DC Load current: 2mA max. None Contact: 1a, Contact capacity: 240V AC 2A/resistive load Proportional cycle: 1~120 sec. Current: 4~20mA DC Load resistance: 600 max. SSR drive voltage: 12V1.5V DC/30mA max. Proportional cycle: 1~120 sec. Voltage: 0~10V DC Load current: 2mA max. 100~240V AC10%, 50/60Hz 24V AC/DC10%, 50/60Hz None Event output (2a) Ev1, Ev2 Contact capacity: 240V AC 1A/resistive load Note: Available only Event output (Ev1) + Heater break alarm (with CT30A) when control output (1) is Y or P is selected. Event output (Ev1) + Heater break alarm (with CT50A) 00 30 Analog output 40 60 08 38 Analog output + Set value bias (S V bias) 48 68 Communication REMARKS 05 07 0 9 None Voltage: 0~10mV DC, Output resistance: 10 Current: 4~20mA DC, Load resistance: 300 max. Voltage: 0~10V DC, Load current: 2mA max. 1 point (setting range: -1999~5000), Non-voltage contact or Open collector input Open collector input rating: approx. 5V/1mA max. Voltage: 0~10mV DC, Output resistance: 10 SV bias 1 point Current: 4~20mA DC, Load resistance: 300 max. SV bias 1 point Voltage: 0~10V DC, Load current: 2mA max. SV bias 1 point RS-485 RS-232C Without With (Please consult before ordering.)

8 INPUT 4 6

Multi input

YICONTROL OUTPUT (1) PVNYCONTROL OUTPUT (2) (OPTION) IPVPOWER SUPPLY 90080 1 EVENT OUTPUT/ HEATER BREAK ALARM (OPTION) 2 3

Set value bias (S V bias) OPTION

Note: When you purchase a two-output type controller and use it in a one output capacity, larger overshooting or undershooting may happen as a result of integral operation. Therefore, we recommend you to choose a one-output type. The cause of the above-mentioned problem is that the positional relationship between the proportional band (PB) and the set value (SV) of a one-output type controller differs from that of a two-output type.

SR91
External Dimensions
48
PV

Series SR90
Panel Cutout
1
+ +
A

Terminal Arrangement
11 12
COM EV1 1A240VAC EV2 1A240VAC

11

111 100

6 7 8
+

2 3

100-240VAC~ 50/60Hz 11VA


N

24VDC 6W /24VAC~ 50/60Hz 7VA

45 +0.6 0 45 +0.6 0 45 +0.6 0

(48 N3) +1 0 60 or more

DC

13 14 15
+ A-output RS-485

48

C
OUT2 EV1 EV2 AT MAN SB/COM

44.6

SV

4 5 11 12 11

9 10

OUTPUT1 4-20mA DC 0-10V DC 30mA 12V DC 2A 240V AC

OUT1

ENT
SR91

In the case of installation without leaving space between instruments N=The number of instruments Unit: mm

B OUTPUT2 4-20mA DC DC 0-10V 30mA 12V DC 2A 240V AC

11 12

CT/SB

SG

11 12

12

SR92
External Dimensions
72
OUT1 OUT2 EV1 EV2 AT

Panel Cutout
111 100
100 or more
SB

Terminal Arrangement
1
+ A-output

11

15 16 17

8 9 10
+

+ 24VDC 8W /24AVC~ 50/60Hz 9VA

PV

68 68 +0.7 0

+0.7 0

2 3
100 or more
+ + CT
A

100-240VAC~ 50/60Hz 15VA


N

SV

C
72 67.6

4 5
COM EV1 1A240VAC EV2 1A240VAC

18 19 20 21 1 1 2 3

11 12 13 14

MAN SB/COM

OUTPUT1 4-20mA DC 0-10V DC 30mA 12V DC 2A 240V AC

DC

ENT

6 7

OUTPUT2 4-20mA DC 0-10V DC 30mA 12V DC 2A 240V AC

SR92

Unit: mm

1
SPECIFICATION RS-232C RS-485 1 SG SG

TERMINAL 2 SD + 3 RD

SR93 AND SR94


External Dimensions SR93
96
PV

Panel Cutout

Terminal Arrangement (Common)

11

111 100

130 or more 92 92 +0.8 0


+0.8 0

+ A-output

1 2 3

11 12 13
+

+ 24VDC 8W /24AVC~ 50/60Hz 9VA

100-240VAC~ 50/60Hz 15VA


N

SB

SV

130 or more

C
91.6 96
EV2 AT MAN SB/COM

OUTPUT1

4 5
CT

14 15 16 17 18 19 20 1

4-20mA DC 0-10V DC 30mA 12V DC 2A 240V AC

OUT1

OUT2

EV1

OUTPUT2 4-20mA DC 0-10V DC 30mA 12V DC 2A 240V AC

ENT

6
+ +
A

7 8

SR93

DC

COM EV1 1A240VAC EV2 1A240VAC

SR94
48 11 111 100

Unit: mm

9 10

PV

45 +0.6 0 92 +0.8 0 92 +0.8 0

(48 N3) +1 0 1

2 3 4

SV

C
91.6 44.6 96

OUT1

OUT2

EV1

EV2

AT

MAN

SB/COM

130 or more

ENT

1 In the case of installation without leaving space between instruments N=The number of instruments
SPECIFICATION RS-232C RS-485 1 SG SG

TERMINAL 2 SD + 3 RD

SR94

Unit: mm

MEASURING RANGE CODES


Input Type B *1 R S K K K E J T N PLII *3 WRe5-26 *4 *5 U *5 L Pt100 R.T.D. Jpt100 -10 0 Voltage 0 (mV) 0 10 0 -1 0 0 Voltage (V) 0 1 0 0 Current (mA) 4 10 10 20 50 50 100 1 1 2 5 5 10 20 20 Code 01 02 03 04 *2 05 06 07 08 09 *2 10 11 12 13 *2 14 31 32 33 34 35 36 37 38 71 72 73 74 75 76 81 82 83 84 85 86 91 92 Measuring range (C) 1800 0 1700 0 1700 0 -199.9 400.0 0.0 800.0 0 1200 0 700 0 600 -199.9 200.0 0 1300 0 1300 0 2300 200.0 -199.9 0 600 600 -200 -100.0 100.0 -50.0 50.0 0.0 200.0 -200 500 -100.0 100.0 -50.0 50.0 0.0 200.0 Scaling possible Refer to the information on the right. Measuring range (F) 3300 0 3100 0 3100 0 -300 750 0 1500 0 2200 0 1300 0 1100 -300 400 0 2300 0 2300 0 4200 400 -300 0 1100 -300 1100 -150.0 200.0 -50.0 120.0 0.0 400.0 -300 1000 -150.0 200.0 -50.0 120.0 0.0 400.0

Series SR90
Owing to scaling function, any measuring range can be set within the following range. Scaling range: -1999 to 9999 counts 10 to 5000 counts on condition of Span: lower side < higher side *1 Thermocouple: B: Accuracy guarantee not applicable to 400C (752F) and below. *2 Thermocouple K, T, U: Accuracy of those whose readings are below -100C is 0.7% FS *3 Thermocouple PLII: Platinel *4 Thermocouple Wre5-26: A product of Hoskins *5 Thermocouple U, L: DIN 43710

Thermocouple

Multi-input

NOTE: Unless otherwise specified, the measuring range will be set as listed below during the shipment from the factory. Input Multi-input Voltage (V) Current (mA) Specification/Rating K thermocouple 0 ~ 10V DC 4 ~ 20mA DC Measuring range 0.0 ~ 800.0C 0.0 ~ 100.0 0.0 ~ 100.0

TERMINAL COVER (AVAILABLE SEPARATELY)


SR91 SR92 SR93 Model QCR001 QCR002 QCR003 Mounting One-touch mount One-touch mount One-touch mount Model QCR004 (Individual mounting) SR94 QCR005 (Tight-lock coupling) Mounting Plus screw, B tight, M2.3 6 - 2 pcs. Plus screw, B tight, M2.3 6 - 4 pcs.

Material/Appearance: PVC/transparent Thickness: 1 mm

Material/Appearance: PVC/transparent Thickness: 1 mm

Mounting: 2+B tight pan-head screws M2.3 6mm

Warning The SR90 series is designed for the control of temperature, humidity and other physical values of general industrial equipment. (It is not to be used for any purpose which regulates the prevention of serious effects on human life or safety.) Caution If the possibility of loss or damage to your system or property as a result of failure of any part of the process exists, proper safety measures must be made before the instrument is put into use so as to prevent the occurrence of trouble.

ISO 9001
(The contents of this brochure are subject to change without notice.)

Temperature and Humidity Control Specialists

Head Office: 2-30-10 Kitamachi, Nerima-Ku, Tokyo 179-0081 Japan Phone: +81-3-3931-7891 Fax: +81-3-3931-3089 E-MAIL: exp-dept@shimaden.co.jp URL: http://www.shimaden.co.jp

02DSR90500ILC

Vous aimerez peut-être aussi