PNMT (Java version) Operation Manual


(for 5000S)

NEC Corporation
Copyright 2007

ROI-S06269

Table of Contents
DOCUMENT WARRANTY ................................................................................................. 1 1 GETTING STARTED .................................................................................................... 2
1.1 1.2 1.3 1.4 INTRODUCTION ..............................................................................................................2 CONNECTABILITY TO OTHER NEC PDH/SDH RADIO EQUIPMENT ................................2 CONVENTIONS USED IN THIS MANUAL .........................................................................2 PNMT COMMUNICATION INTERFACES ..........................................................................3

1.4.1 1.4.2 1.4.3


1.5 1.6 1.7

Communications .......................................................................................................3 PNMT Port Interface................................................................................................3 PNMT network settings ...........................................................................................4


EQUIPMENT CONFIGURATION OF 5000S .......................................................................5 HARDWARE REQUIREMENTS..........................................................................................5 SOFTWARE REQUIREMENTS...........................................................................................5 THE PNMT SCREEN ......................................................................................................6 LAUNCHING THE PNMT APPLICATION ..........................................................................9 LOGIN ..........................................................................................................................10

SYSTEM OPERATION & MAINTENANCE................................................................ 6


2.1 2.2 2.3

2.3.1
2.4 2.5 2.6 2.7 2.8 2.9 2.10

User Access Level Privileges..................................................................................12


SHUTTING DOWN THE PNMT......................................................................................14 SEARCHING FOR NETWORK ELEMENTS AND CONNECTING TO SELECTED NE.............15 CHANGE PASSWORD ....................................................................................................16 ALARM BUZZER SETTING .............................................................................................17 REFRESH .....................................................................................................................18 REMOTE VIEWING OF PNMT MAIN WINDOW ..............................................................19 LICENSE ......................................................................................................................20 TRP UNIT ....................................................................................................................23 TRP UNIT - MODULE DETAIL .....................................................................................24

ALARM/STATUS .........................................................................................................23
3.1 3.2

3.2.1 3.2.2 3.2.3 3.2.4


3.3

TRP Tab ..................................................................................................................25 SD Tab.....................................................................................................................26 2SD Tab...................................................................................................................27 FAN Tab..................................................................................................................28


TRP UNIT - SYS DETAIL ............................................................................................29

3.3.1
3.4 3.5

SYS** Tab ...............................................................................................................29


MDP[01-05] UNIT .......................................................................................................30 MDP[01-05] UNIT - MODULE DETAIL.........................................................................31

3.5.1 3.5.2 3.5.3 3.5.4 3.5.5 3.5.6 3.5.7 3.5.8 3.5.9 3.5.10 3.5.11 3.5.12

LMS Tab..................................................................................................................32 OW Tab ...................................................................................................................33 DIGHYB Tab...........................................................................................................34 SWO PROC (HS/TP) Tab .......................................................................................35 SWO PROC(N+1) Tab ............................................................................................36 TR DIST Tab...........................................................................................................37 BB SW CTRL Tab...................................................................................................38 CLK(W) Tab ............................................................................................................41 CLK(P) Tab .............................................................................................................41 OH/WS INTFC Tab ................................................................................................42 CTRL Tab................................................................................................................45 MUX Tab.................................................................................................................46

-i-

ROI-S06269

3.5.13 3.5.14 3.5.15 3.5.16 3.5.17 3.5.18


3.6

MODEM Tab...........................................................................................................47 OPT INTFC(W) Tab................................................................................................49 OPT INTFC(P) Tab.................................................................................................50 150M INTFC Tab....................................................................................................51 DC-DC CONV Tab ..................................................................................................52 PS CONV Tab .........................................................................................................52
MDP[01-05] UNIT -SYS DETAIL.................................................................................53

3.6.1 3.6.2
3.7

MDP COMMON Tab ..............................................................................................54 SYS** Tab ...............................................................................................................54


MDP[06-10] UNIT .......................................................................................................54 LINE SUMMARY ...........................................................................................................55 LINE DETAIL................................................................................................................56

LINE UNIT...................................................................................................................55
4.1 4.2

4.2.1

4.2.1.1 4.2.1.2 4.2.1.3 4.2.1.4 4.2.1.5 4.2.1.6

REGxx tab...............................................................................................................58

Recovery (Rcvy) Operation....................................................................................................... 60 Excercise ................................................................................................................................... 60 Counter Operation ................................................................................................................... 61 Switch Over Operation............................................................................................................. 62 Disable Operation .................................................................................................................... 63 TX Test Operation.................................................................................................................... 64

EXTERNAL DI/DO ......................................................................................................65


5.1 EXTERNAL DI/DO DETAIL ...........................................................................................65

5.1.1 5.1.2

5.1.2.1 5.1.2.2 5.1.2.3 5.1.2.4

DI Tab .....................................................................................................................66 DO Tab ....................................................................................................................67

External DI Configuration....................................................................................................... 68 External DO Configuraion....................................................................................................... 69 External DO Control(Pulse)..................................................................................................... 70 External DO Control(Latch) .................................................................................................... 71

SYSTEM MAINTENANCE..........................................................................................72
6.1 SYSTEM MAINTENANCE DETAIL ..................................................................................72
6.1.1.1 6.1.1.2 6.1.1.3 6.1.1.4 6.1.1.5 6.1.1.6 6.1.1.7 6.1.1.8 6.1.1.9 6.1.1.10 6.1.1.11 6.1.1.12 6.1.1.13 6.1.1.14

6.1.1

System Maintenance ..............................................................................................73

Note........................................................................................................................................... 74 Download Configuration File(Network Config/MIB Config) .................................................. 74 Download Configuration File(System Parameter Config)...................................................... 76 Download Configuration File(System Parameter Config)...................................................... 77 Download Program File (CTRL subfile - individual) .............................................................. 78 Download Program File ........................................................................................................... 79 Download Program File ........................................................................................................... 80 CPU Reset(LMS/CTRL/SWO PROC) ...................................................................................... 81 CPU Reset(MODEM/TRP/SD/2SD) ......................................................................................... 82 Upload Configuration File ................................................................................................... 83 System Parameter................................................................................................................ 84 Date/Time ............................................................................................................................. 85 Equipment Network Setting................................................................................................ 86 MAINT .................................................................................................................................. 87

PROVISIONING ..........................................................................................................88
7.1 7.2 MENU.........................................................................................................................88 SETTING METHOD ..................................................................................................89

7.2.1 7.2.2
7.3

METHOD-1: Common setting to all SYS ..............................................................89 METHOD-2: Independent setting to each SYS .....................................................89
DETAILS ....................................................................................................................91

7.3.1 7.3.2 7.3.3 7.3.4

Transmitter and Receiver ......................................................................................91 Orderwire ................................................................................................................92 Orderwire Digital Hybrid.......................................................................................93 Radio Protection Switchover for N+1 Configuration ............................................94

- ii -

ROI-S06269

7.3.5 Automatic Protection Switching for Optical Interface Redundancy ....................95 7.3.6 SDH Clock Synchronization for Multiplexer Section Termination Mode ............96 7.3.7 Alarm Reporting and Exernal Relay Output ........................................................96 7.3.8 Radio Frame Performance Monitor .......................................................................97 7.3.9 STM-1 Frame Performance Monitor......................................................................98 MAINTENANCE CONTROL.....................................................................................100
8.1 8.2 MENU.......................................................................................................................100 SETTING METHOD ................................................................................................100

8.2.1 8.2.2
8.3

METHOD-1: MODULE basis operation ..............................................................100 METHOD-2: SYS basis operation........................................................................100


DETAILS ..................................................................................................................103

8.3.1 8.3.2

8.3.3 Cross Polarization Interference Canceller Reset ................................................108 8.3.4 PROT-REG Delay Adjustment for Hitless Switching .........................................109 8.3.5 Wayside Switchover Manual Control ..................................................................110 8.3.6 SDH Clock Synchronization for Multiplexer Section Termination Mode ..........111 8.3.7 Radio Protection Switchover Manual Control.....................................................111 8.3.8 Automatic Protection Switchover Manual Control .............................................112 MAINTENANCE TEST .............................................................................................113
9.1 9.2 MENU.......................................................................................................................113 SETTING METHOD ................................................................................................113

8.3.2.1 8.3.2.2

Fixed Transmit Level Setting for occasional operation without ATPC .............103 MAIN-SD Delay Adjustment for IF signal combiner..........................................104

Adjust.......................................................................................................................................105 Adjust Operation .....................................................................................................................106

9.2.1 9.2.2
9.3

METHOD-1: MODULE basis operation ..............................................................113 METHOD-2: SYS basis operation........................................................................113


DETAILS ..................................................................................................................116

9.3.1 TRP Test Function................................................................................................116 9.3.2 MODEM Test Function ........................................................................................117 9.3.3 Baseband Loopback Test and STM-1 Pulse Mask Measurement ......................118 9.3.4 WS Pulse Mask Measurement .............................................................................119 9.3.5 Radio Protection Switchover Test........................................................................120 9.3.6 Automatic Protection Switchover Reset ..............................................................120 10 MAINTENANCE INFORMATION............................................................................121
11 LINK PERFORMANCE MONITOR ..........................................................................123
11.1 11.2 12.1 13.1 14.1 15.1 16.1 VIEWING SUMMARY LINK PERFORMANCE MONITOR .................................................125 THRESHOLD SETTING ................................................................................................127 VIEWING SUMMARY METERING WINDOW..................................................................131 EVENT LOG MONITOR ................................................................................................132 ALARM LIST WINDOW ................................................................................................133 INVENTORY MONITOR................................................................................................134 ERROR MESSAGE WHEN MULTIPLE CONTROLLING OPERATIONS ARE UNDERWAY ......135

11.1.1 Link Performance Monitor (1day / 15 min. Data) window .................................126


12 METERING ................................................................................................................130 13 EVENT LOG...............................................................................................................132 14 ALARM LIST..............................................................................................................133 15 INVENTORY ..............................................................................................................134 16 CAUTIONARY NOTES..............................................................................................135

- iii -

ROI-S06269

Document Warranty
1. The information contained in this document is subject to change without prior notice. 2. The PNMS/PNMT screen shots in this manual are only examples. Screens or windows will vary according to equipment configurations, equipment operation modes, setting parameters, PNMS/PNMT application program version, etc. Screens or windows contained in this manual are current at the moment of publishing; however, they may differ slightly from the actual ones of your PNMS/PNMT. 3. This manual is written on the assumption that you already understand the restrictions, limitations and precautions necessary to operate the equipment properly. Refer to the equipment manual for details.

-1-

ROI-S06269

1
1.1

Getting Started
Introduction
The PNMT is a computer-based Network Management Terminal system developed by NEC for management of NECs SDH/PDH Radio Equipment wireless transmission network. The PNMT is a scaled down version of PNMS that is designed as a maintenance tool for field engineers to locally and remotely monitor alarms, control points, generate reports, and archive data, all within a familiar graphical user interface, and all in real time. Throughout this manual, the PNMT generally refers to the mobile laptop computer in which the NEC PNMT software package (that interfaces and controls NEC 5000S series short haul wireless equipment) is installed. This software package remotely monitors and controls the status and configuration of an entire 5000S network with associated equipment as well as the performance of the actual microwave links.

1.2

Connectability to other NEC PDH/SDH Radio Equipment


The current PNMT application only supports connectability to 5000S wireless equipment. (Attempts to link to other NEC PDH/SDH Radio Equipment are liable to cause the application to not function properly and connection to fail)

1.3

Conventions Used in This Manual


Font Italic Hostname Bold [Button] What the Font Represents For manual titles or related document names. Items on the user interface. Items on the computer display. File and directory names. Buttons on the user interface. Example Please refer to 5000S Operation Manual for details. The Overall window Click [OK] button to continue Click [Execute] button to send command. Select System Login/Logout

Menu Items

<username>

A menu name followed by a colon (:) means that you must select the menu and then item. When the item is followed by an arrow ( ), a cascading menu follows. A command variable where the user must enter the appropriate value. This is also commonly used when asking for a password. Keyboard keys.

<password>

Keycap

Press Enter key.

-2-

ROI-S06269

1.4
1.4.1

PNMT Communication Interfaces


Communications Communication between the PNMT and the wireless network equipment are possible via the PNMT port on the LMS module of the equipment.

1.4.2

PNMT Port Interface

The PNMT port on the LMS module can be accessed by opening the hatch of the MDP front panel.

LAN Cable

LAN Port

LMS Module

PNMT NE Connection

-3-

ROI-S06269

The LMS modules mounted on the PNMT and equipment are connected by LAN cable. PNMT port specifications:PNMT connected to some 5000S may not be able to be linked to other 5000S equipment. 10BASE-T(fixed Half Duplex)

WARNING!!! PNMT connected to certain 5000S may not be able to be connected to others. If the ARP cache of 5000S equipment connected to the PNMT computer remains, the MAC address of the previously connected equipment would be used to connect to the present equipment. The ARP cache is automatically cleared within about 10 seconds of the LAN cable being disconnected. Alternatively, it can also be cleared manually using the following procedure. Clearing the ARP cache 1. Launch the Command Promptwindow. 2. Execute arp d command.

1.4.3

PNMT network settings

When connecting NE (network elements) to PNMT, the following TCP/IP settings are to be used: Item IP Address Subnet mask Default gateway Setting 172.17.254.254 255.255.255.252 172.17.254.253

-4-

ROI-S06269

1.5

Equipment Configuration of 5000S


The 5000Sis configured as 4-11 GHz 64/128 QAM DMR-5000 SDH Microwave Radio Equipment (for details, please refer to: manual ROI-S06205-051E)

1.6

Hardware Requirements
Recommended configuration of PNMT mobile computer. CPU: RAM: HD: Display: FD drive CD-ROM drive Serial port (RS-232C) 10/100BASE-T(X) LAN port LAN Cable Internal sound system with speaker Pentium M 2.26GHz or equivalent 1GB or more 40GB or more colour LCD (1,024 768) or more

1.7

Software Requirements
OS: Windows Xp Professional (English version) with SP2 or higher IE6.0 with SP2 or higher Java Runtime Environment v 1.4.2_11 or higher (JRE v 1.5 is not currently supported.) Adobe Reader PNMT Application software

-5-

ROI-S06269

System Operation & Maintenance


This chapter explains the menu structure and procedures for operating the PNMT. The explanation uses typical PNMT screens or windows to illustrate the hierarchy of menu.

2.1

The PNMT Screen


The PNMT window comprises the following main parts (Refer to Figure 1). Title Bar

The title bar of the window is used to indicate its title. Common Menu Bar

The common menu bar of the window presents the System, Refresh and Help options, illustrates the commands that can be executed from the various options. The Help function can also be used to display the operation manual. Common Tool Bar

In the Common Tool Bar, the NE connections (to the PNMT) as well as the screen display can be refreshed and the buzzer sound can be stopped.

NE-specific Menu Bar

This menu is a list of tasks that can be performed in regard to the specific network element (NE) displayed in the PNMT. Configuration, Event Log, Link Performance Monitor and Alarm List functions can be executed in the NE-specific menu bar. Rack Summary

The Rack Summary provides an overview of warning status, status values, and the state of maintenance for the respective rack. Module Summary

The Module Summary provides an overview of the module mounting state, the warning status, and the relevant status values. Line Summary

The Line Summary provides an overview of the warning status for each signal line of the N+1 configuration and the status summary as well as the switch status. Others

The status of EXTERNAL DI/DO and LPM warnings, as well as the Status value summary, and the INVENTORY are displayed in the Others column.

Tabs

To view the status and alarms in the specific part of the NE, click on the tab at the bottom of the Data window. Command Button

The command button is used to enter the data selected in the pop-up window into the computer. Text Box
-6-

ROI-S06269

This is a standard Windows dialog box where the user inputs the desired value. Login User

This indicates the user currently logged-in to the PNMT. Background colour attribute for each alarm and status

The respective Background colour for each alarm and status is as follows: normal: Green, major alarm: Red, minor alarm: Pink, status value: White, disabled: Gray, maintenance: Yellow

-7-

ROI-S06269

Title Bar Common Menu Bar Common Tool Bar

NE-Specific Menu Bar

Module Summary

Rack Summary

Line Summary

Others

Login User

Radio Button Text Box Command Button

Tabs

Figure 1 Standard Features of PNMT Window

-8-

ROI-S06269

2.2

Launching the PNMT Application


To start PNMT: Turn ON the computer. NOTE Before logging in to the PNMT, be sure to connect the LAN cable to the LMS modules PNMT port. Login to Windows OS. Click Start Programs Pnmtj Pnmt, then continue to the login window.

NOTE Please do not change the clock settings of your computer once PNMT has started.

-9-

ROI-S06269

2.3

Login
Users are registered by means of login name and password. To protect the network and network management system from unauthorized access or unauthorized modifications, five levels (refer to the table shown in section 2.3.1 User Access Level Privilege) of users are defined with different privileges. The functions available in the window depend on the users access level, that determines which of the functions may (or may not) be carried out. The highest level or administrator level (Admin) has full access to the network and the network management system. To login: 1. Start PNMT and the Login window appears.

2. Enter the <user name>. 3. Enter the valid <password> for the specific user. 4. Click the [OK] button. If you wish to exit the program, click [Exit].

- 10 -

ROI-S06269

Login User

- 11 -

ROI-S06269

2.3.1

User Access Level Privileges

: Available, -: Not available

Functions Category
SYSTEM EQUIPMENT SETUP PROVISIONING OPT INTFC

User Name and Accessible Functions Monitor User Local Remote Admin

ITEM
ALARM BUZZER CONNECT (Remote Login) NOTE ERR PLS BER Alarm Threshold ALS Section Trace (J0) from/to MUX Section Trace (J0) from/to DMR PMON SES Threshold 150M INTFC ERR PLS BER Alarm Threshold Section Trace (J0) from/to MUX Section Trace (J0) from/to DMR PMON SES Threshold MODEM BB SW CTRL CTRL TRP SWO PROC OW DIG HYB BER Alarm Threshold PMON SES Threshold Switching Mode Alarm Correlation Provisioning CTRL External DO Configuration ATPC Condition RSL for TCS SWO PROC Provisioning OW Provisioning DIG HYB Provisioning(Encoding Law) DIG HYB Provisioning(DIGHYB Port Select) DIG HYB Provisioning(CLK Mode) DIG HYB Provisioning(CH2 Interface Select) PMON PMON Threshold Data-CTRL PMON Threshold Data-SWO PROC Delay Adjust Delay Adjust Linear Equalizer Setting Switching Control SYS A-B Switching Control SYS C-D SWO PROC Switching Control(TX Side) Switching Control(RX Side) Switch Over Operation Disable Operation RCVY Operation Counter Operation BB SW CTRL Control Mode SYS A Control Mode SYS B Control Mode SYS C Control Mode SYS D Control Mode SYS E Lock-in Status Clear SYS A Lock-in Status Clear SYS B Lock-in Status Clear SYS C Lock-in Status Clear SYS D Lock-in Status Clear SYS E TRP/SD/2SD SD 2SD Manual Transmit Level Control DADE Adjust(Adjust) DADE Adjust(Adjust Operation) DADE Adjust(Adjust) DADE Adjust(Adjust Operation) Loopback Test

MAINTENANCE CONTROL

OPT INTFC 150M INTFC MODEM OH/WC INTFC

MAINTENANCE

OPT INTFC

- 12 -

ROI-S06269

: Available, -: Not available

Functions Category
TEST 150M INTFC MODEM

User Name and Accessible Functions Monitor User Local Remote Admin

ITEM
Base Band Output Test Loopback Test MOD Carrier Output Loopback Test DEM Carrier NORM/INV Select Antenna Alignment Mode OH/WS INTFC BB SW CTRL TRP Wayside Output Test SYS A-B Wayside Output Test SYS C-D All Reset Receive Level AGC Function Carrier Sweep Function Transmit Power Mute TRP Frequency SWO PROC TX Test Exercise CPU Reset<LMS/CTRL/SWO PROC> CPU Reset<MODEM/TRP/SD/2SD> Download Configuration File(Config File) Download Configuration File(System Parameter File) Download Configuration File(System Parameter File (Module Unit)) Upload Configuration File(Config File) Upload Configuration File(System Parameter File) Download Program File(LMS/CTRL/SWO PROC) Download Program File(MODEM/TRP/SD/2SD) Download Program File(All SYS under CTRL) MAINT Update Configuration File Date/Time Equipment Network Setting Note

SYSTEM MAINTENANCE

External DI/DO

External DI Configuration External DO Configuration External DO Control(Pulse) External DO Control(Latch)

*Admin: *Remote: *Local: *User: *Monitor:

Enabled to access all Network Elements. Enabled to access all Network Elements. (Disabled from changing network configuration and changing/downloading programs) Enabled to access all Network Elements. ((Disabled from changing network configurations and changing/downloading programs)) Enabled only to access items which do not affect the equipment. Enabled only to monitor (disabled from control).

- 13 -

ROI-S06269

2.4

Shutting Down the PNMT


To close the PNMT application:

Click System

Exit in the menu bar in the PNMT main window.

Click [OK] button in the confirmation message window to close the application.

- 14 -

ROI-S06269

2.5

Searching for Network Elements and Connecting to Selected NE


The summary description (NE Name, Equipment Type, Opposite NE, etc.) of the current NE where PNMT is connected can be displayed using this function. Summary description of the opposite NE belonging to that link is also displayed. To search for or connect to NE in the network: 1. Click System Connect in menu bar of PNMT main window.

NOTE Initially only the current NE physically connected to the PNMT and its opposite NE will be shown in the Network Element List. Click on icon in the tool bar or List Search for Network Element in the menu bar of the Network Element List window to display all connectable Network Elements in the network. Select and highlight the Network Element to be viewed. icon in the tool bar or List Connect to Network Element in the menu Click on bar of the Network Element List window. The PNMT main window for both the selected, and its opposite, Network Element will be displayed. NOTE Simultaneous connection from multiple PNMTs to the same NE is possible: 1 Local connection PNMT is directly connected to the NE 2 Opposite connection PNMT is connected to opposite NE (of the local counterpart) 3 Remote connection PNMT is connected to the NE by remote access.

- 15 -

ROI-S06269

2.6

Change Password
To change the password: 1. Click System Change Password in the menu bar on PNMT main window.

Enter the old <password>. Enter new <password>. Enter the new <password> again in the Confirm New Password box to confirm. Click [OK] button. NOTE For details on initial user name and password, please refer to PNMT Installation Manual.

- 16 -

ROI-S06269

2.7

Alarm Buzzer Setting


This feature is used to activate and set the Alarm Buzzer. It can also be used to set the desired sound scheme. To set the Alarm Buzzer: 1. Click System Alarm Buzzer in the menu bar of the PNMT main window.

Select the Wave file to activate the buzzer. No sound is the initial factory setting of the PNMT. If you select the Wave file box, enter the location of the sound file (*.wav) Otherwise; click the browse button to locate the desired file. You can also preview the *.wav file by clicking on the arrow button next to the browse button. Click the [OK] button to activate the new setting.

- 17 -

ROI-S06269

2.8

Refresh
This function is supported only by PNMT. This function enables PNMT to manually obtain metering and alarm status, as well as to update equipment information. To Refresh: Click Refresh Refresh in the menu bar or click on the refresh icon in the tool bar.

- 18 -

ROI-S06269

2.9

Remote Viewing of PNMT Main Window


You can view the target link underlying the one Root NE in the managed network by determining (searching) the connectable NEs and then connecting to a target NE. Please refer to Section 2.5 Searching for Network Elements and Connecting to Selected NE. This feature allows you to remotely connect to any NE in the network.

PNMT Main Window

- 19 -

ROI-S06269

2.10 License
To protect PNMT functions, the PNMT application includes license files. To display the current license status: 1. Click Help License in the main window.

Click [Close] to shutthis window. If you wish to change the license file, click [Import], and proceed according to the following procedure. Click [Next] to continue.

- 20 -

ROI-S06269

Specify the License.Key file (if one is available). Click [Next].

The progress of Check License File will be displayed. If no error is encountered during importing of the license file, click [Next] as soon as the button becomes available.

- 21 -

ROI-S06269

Confirm the type of license Imported, and click [Next].

Click [Finish] in ensuing window to 24 Import License Wizard.

- 22 -

ROI-S06269

Alarm/Status
The Alarm/ Status feature allows the alarm monitoring status to be checked in the Detail window.

3.1

TRP Unit
In the TRP Unit's Detail window, the monitored items for the TRP/SD/2SD/FAN (mounted in the TRP Unit) is displayed (however, no actual functions are available from this window). However, two display options are available here: "Module Detail" and "SYS Detail".

- 23 -

ROI-S06269

3.2

TRP Unit - Module Detail


The Module Detail format shows a list of the status of monitored items for the respective module.

The MODULE Detail list can be displayed by either of the following methods: Left-click the TRP icon in the Rack Summary. After right-clicking the TRP icon in the Rack Summary, select [MODULE] from the ensuing short cut menu.

Click the TRP/SD/2SD/FAN icon in the Module Summary. After right-clicking the TRP/SD/2SD/FAN icon in the Module Summary. Select [MODULE] from the ensuing short cut menu.

- 24 -

ROI-S06269

3.2.1

TRP Tab

The TRP tab displays the status of the monitored TRP items. This window only displays current settings and no control functions are available here.

Overview and description of the items monitored in the TRP

Module TRP

Item/Feature Unequipped TX Level TX APC RX APC Receive Level TRP Temperature Reference CLK Unlock TX INPUT Level ATPC PS Service State

Severity MJ MJ MJ MJ MJ MJ MJ MJ MJ MJ ST

Description No response from TRP to CTRL. TX output power is outside the nominal range. TX APC (Automatic Phase Control) is outside the nominal range. RX APC is outside the nominal range. Receive level is outside the nominal range. Temperature for inside of TRP is outside the nominal range. When during XPIC configuration, it is not possible to synchronize with the CLK Reference from the modem Input level is down at TX IF IN. ATPC data communication error occurs or ATPC level is outside the nominal range. PS module failure/malfunction. In Service (Normal) : In working order. In Service (Abnormal) : Occurred alarm of PM and/or DM. Out Of Service (Maintenance) : Maintenance item in operation.

Status Indication Normal / Alarm Normal / Alarm Normal / Alarm Normal / Alarm Normal / Alarm Normal / Alarm Normal / Alarm Normal / Alarm Normal / Alarm Normal / Alarm In Service (Normal) / In Service (Abnormal) / Out Of Service (Maintenance) Completed / Standby Off / On Off / On Off / On Off / On

Provisioning Modulator Carrier Out Control Carrier Sweep Function Status Out Of Service Mute Status

ST ST ST ST ST

Provisioning has not been configured from CTRL to TRP When modulator (MOD) is under Carrier OUT control When Carrier Sweep function is in operation Test MODE (during shipping) During TX POWER MUTE

- 25 -

ROI-S06269

3.2.2

SD Tab

The SD tab displays the status of the monitored SD items. This window only displays current settings and no control functions are available here.

Overview and description of the items monitored in the SD

Module SD

Item/Feature Unequipped Local Level Main Receive Level Receive Level Control PS Service State

Severity MJ MJ MJ MJ MJ MJ ST

Description No response from SD to CTRL. SD RX Local level is outside the nominal range. Receive level of MAIN signal is outside the nominal range. Receive level of combine signal is outside the nominal range. When integrated control of MAIN and SD signal is not possible PS module failure/malfunction. In Service (Normal) : In working order. In Service (Abnormal) : Occurred alarm of PM and/or DM. Out Of Service (Maintenance) : Operated maintenance item.

Status Indication Normal / Alarm Normal / Alarm Normal / Alarm Normal / Alarm Normal / Alarm Normal / Alarm In Service (Normal) / In Service (Abnormal) / Out Of Service (Maintenance) Completed / Standby Off / On Off / On

Provisioning DADE Adjust Status Out Of Service

ST ST ST

Status of writing from CTRL to SD. During DADE Adjust process Test MODE (during shipping)

- 26 -

ROI-S06269

3.2.3

2SD Tab

The 2SD tab displays the status of the monitored 2SD items. This window only displays current settings and no control functions are available here.

Overview and description of the items monitored in the 2SD

Module 2SD

Item/Feature Unequipped Main Receive Level Local Level Receive Level Control PS Service State

Severity MJ MJ MJ MJ MJ MJ ST Not equipped with 2SD.

Description SD RX Local level is outside the nominal range. Receive level of MAIN signal is outside the nominal range. Receive level of combine signal is outside the nominal range. When integrated control of MAIN and SD signal is not possible PS module failure/malfunction. In Service (Normal) : In working order. In Service (Abnormal) : Occurred alarm of PM and/or DM. Out Of Service (Maintenance) : Maintenance item in operation.

Status Indication Normal / Alarm Normal / Alarm Normal / Alarm Normal / Alarm Normal / Alarm Normal / Alarm In Service (Normal) / In Service (Abnormal) / Out Of Service (Maintenance) Completed / Standby Off / On Off / On

Provisioning DADE Adjust Status Out Of Service

ST ST ST

Status of writing from CTRL to SD. During DADE Adjust process Test MODE (during shipping)

- 27 -

ROI-S06269

3.2.4

FAN Tab

The FAN tab displays the status of the monitored FAN items. This window only displays current settings and no control functions are available here.

Overview and description of the items monitored on the FAN tab

Module FAN

Item/Feature FAN Service State

Severity MJ ST2 ST1 ST1

Description FAN unit failure. In Service (Normal) : In working order. In Service (Abnormal) : Occurred alarm of PM and/or DM. Out Of Service (Maintenance) : Maintenance item in operation.

Status Indication Normal / Alarm In Service (Normal) / In Service (Abnormal) / Out Of Service (Maintenance)

- 28 -

ROI-S06269

3.3

TRP Unit - SYS Detail


In the SYS Detail list, the monitoring status of each module in terms of specific systems (SYS) is displayed according to various tabs.

The SYS Detail list can be displayed by either of the following methods:

After right-clicking the TRP icon in the Rack Summary, select [SYS] from the ensuing short cut menu.

After right-clicking the TRP/SD/2SD/FAN icon in the Module Summary. Select [SYS] from the ensuing short cut menu.

3.3.1

SYS** Tab

This status display shows only the SYS items selected via the tab; otherwise it is identical to the MODULE DETAIL feature.

- 29 -

ROI-S06269

3.4

MDP[01-05] Unit
The Detail view for the MDP[01-05] Unit only displays the monitoring items for the modules actually mounted in the unit. However, two display options are available here: "Module Detail" and "SYS Detail".

- 30 -

ROI-S06269

3.5

MDP[01-05] Unit - Module Detail

In the Module Detail list, the monitoring status of each module in terms of specific modules is displayed according to various tabs.

The MODULE Detail list can be displayed by either of the following methods:

Left-click the MDP icon in the Rack Summary. After right-clicking the MDP icon in the Rack Summary, select [MODULE] from the ensuing short cut menu.

Left-click the respective module icon in the MDP column of the Module Summary. After right-clicking the respective module icon in the Rack Summary, select [MODULE] from the ensuing short cut menu.

- 31 -

ROI-S06269

3.5.1

LMS Tab

The LMS tab displays the status of the monitored LMS items. This window only displays current settings and no control functions are available here.

Overview and description of the items monitored in the LMS

Module LMS

Item/Feature Confidence Check CTRL xx COM CTRL xx Date Time Set CTRL xx MDCPU Date Time Set CTRL xx Status SYNC SWO PROC xx COM SWO PROC xx Date Time Set SWO PROC xx Status SYNC Database Check Unit Fail CTRL xx Startup SWO PROC xx Startup Startup

Severity ST2 MJ MJ MJ MJ MJ MJ MJ MJ MJ ST2 ST2 ST2

Description LMS confidence check is being executed. Indicates the status of communication with CTRLxx Indicates whether CTRLxx clock was successfully set (or not) Indicates whether MDCPU clock was successfully set (or not) Indicates whether status synchronization (SYNC) with CTRLxx was successful(or not) Indicates the status of communication with SWO PROCxx Indicates whether CTRLxx clock was successfully set (or not) Indicates whether status synchronization (SYNC) with SWO PROC xx was successful(or not) Indicates that Database Check is being performed Indicates LMS unit failure/malfunction. Indicates CTRLxx startup status Indicates SWO PROC startup status Indicates LMS startup status

Status Indication Start / End Normal / Alarm Normal / Alarm Normal / Alarm Normal / Alarm Normal / Alarm Normal / Alarm Normal / Alarm Normal / Alarm Normal / Alarm Standby / Completed Standby / Completed Standby / Completed

- 32 -

ROI-S06269

3.5.2

OW Tab

The LMS tab displays the status of the monitored LMS items. This window only displays current settings and no control functions are available here.

Overview and description of the items monitored in the OW

Module OW

Item/Feature Unequipped Module Type Mismatch Unit Fail Service State

Severity MJ MJ MJ ST2 ST1 ST1

Description Not equipped with OW. No response from OW to CTRL. Module type mismatch. OW unit failure. In Service (Normal) : In working order. In Service (Abnormal) : Occurred alarm of PM and/or DM. Out Of Service (Maintenance) : Maintenance item in operation.

Status Indication NORMAL / ALARM NORMAL / ALARM NORMAL / ALARM In Service (Normal) / In Service (Abnormal) / Out Of Service (Maintenance)

- 33 -

ROI-S06269

3.5.3

DIGHYB Tab

The DIGHYB tab displays the status of the monitored DIBHYB items. This window only displays current settings and no control functions are available here.

Overview and description of the items monitored in the DIGHYB

Module DIG HYB

Item/Feature Unequipped Module Type Mismatch Unit Fail HYB CLK Input MUX CLK Input DMR CLK Input CH1 CLK Set Error CH2 CLK Set Error CH3 CLK Set Error CH4 CLK Set Error CH5 CLK Set Error Service State

Severity MJ MJ MJ MN MN MN MN MN MN MN MN ST2 ST1 ST1 ST2 ST2 ST2 ST2

Description Not equipped with DIG HYB. No response from DIG HYB to CTRL. Module type mismatch. DIGHYB unit failure. Clock input to HYB interface Clock input to MUX interface Clock input to DMR interface CH1(HYB)configuring error CH2(MUX)configuring error CH3(DMR)configuring error Unused Unused In Service (Normal) : In working order. In Service (Abnormal) : Occurred alarm of PM and/or DM. Out Of Service (Maintenance) : Maintenance item in operation. Internal clock uses digital hybrid operating standard HYB input clock uses digital hybrid operating standard MUX input clock uses digital hybrid operating standard Internal clock uses digital hybrid operating standard

Status Indication Normal / Alarm Normal / Alarm Normal / Alarm Normal / Alarm Normal / Alarm Normal / Alarm Normal / Alarm Normal / Alarm Normal / Alarm Normal / Alarm Normal / Alarm In Service (Normal) / In Service (Abnormal) / Out Of Service (Maintenance) Off / On Off / On Off / On Off / On

Base CLK OWHYB Base CLK HYB Base CLK MUX Base CLK DMR

- 34 -

ROI-S06269

3.5.4

SWO PROC (HS/TP) Tab

The SWO PROC (HS/TP) tab displays the status of the monitored SWO PROC (HS/TP) items. This window only displays current settings and no control functions are available here.

Overview and description of the items monitored in the SWO PROC(HS/TP)

Module SWO PROC (HS/TP)

Item/Feature Unequipped Module Type Mismatch Service State

Severity MJ MJ ST2 ST1 ST1

Description Not equipped with SWO PROC. No response from SWO PROC to CTRL. Module type mismatch. In Service (Normal) : In working order. In Service (Abnormal) : Occurred alarm of PM and/or DM. Out Of Service (Maintenance) : Maintenance item in operation.

Status Indication Normal/Alarm Normal/Alarm In Service (Normal) / In Service (Abnormal) / Out Of Service (Maintenance)

- 35 -

ROI-S06269

3.5.5

SWO PROC(N+1) Tab

The SWP PROC(N+1) tab displays the status of the monitored SWO PROC(N+1) items. This window only displays current settings and no control functions are available here.

Overview and description of the items monitored in the SWO PROC (N+1)

Module SWO PROC (N+1)

Item/Feature Unequipped Service State

Severity MJ ST2 ST1 ST1

Description Not equipped with SWO PROC. No response from SWO PROC to LMS. In Service (Normal) : In working order. In Service (Abnormal) : Occurred alarm of PM and/or DM. Out Of Service (Maintenance) : Maintenance item in operation.

Status Indication Normal/Alarm In Service (Normal) / In Service (Abnormal) / Out Of Service (Maintenance)

- 36 -

ROI-S06269

3.5.6

TR DIST Tab

The TR DIST tab displays the status of the monitored TR DIST items. This window only displays current settings and no control functions are available here.

Overview and description of the items monitored in the TR DIST

Module TR DIST

Item/Feature Unequipped Module Type Mismatch Unit Fail AL INTFC Service State

Severity MJ MJ MJ MJ ST2 ST1 ST1

Description Not equipped with TR DIST. No response from TR DIST to CTRL. Module type mismatch. TR DIST unit failure. Status of communication with SWO PROC In Service (Normal) : In working order. In Service (Abnormal) : Occurred alarm of PM and/or DM. Out Of Service (Maintenance) : Maintenance item in operation. Protection access transmission is in operation. (TX side) Protection access transmission is in operation. (RX side) SYS A switched to protection channel by TX SW. SYS B switched to protection channel by TX SW. SYS C switched to protection channel by TX SW. SYS D switched to protection channel by TX SW. SYS E switched to protection channel by TX SW.

Status Indication Normal / Alarm Normal / Alarm Normal / Alarm Normal / Alarm In Service (Normal) / In Service (Abnormal) / Out Of Service (Maintenance) Off / On Off / On Off / On Off / On Off / On Off / On Off / On

RX PROT Access OP TX PROT Access OP SYS A TX SW OP SYS B TX SW OP SYS C TX SW OP SYS D TX SW OP SYS E TX SW OP

ST2 ST2 ST2 ST2 ST2 ST2 ST2

- 37 -

ROI-S06269

3.5.7

BB SW CTRL Tab

The BB SW CTRL tab displays the status of the monitored BB SW CTRL items. This window only displays current settings and no control functions are available here.

Overview and description of the items monitored in the BB SW CTRL

Module BB SW CTRL

Item/Feature Unequipped Module Type Mismatch Service State

Severity MJ MJ ST2 ST1 ST1

Description Not equipped with BB SW CTRL. No response from BB SW CTRL to CTRL. Module type mismatch. In Service (Normal) : In working order. In Service (Abnormal) : Occurred alarm of PM and/or DM. Out Of Service (Maintenance) : Maintenance item in operation. APS control BUS is disabled. BB SW CTRL unit failure. Lock-in control in operation [SYS A] Far end Protection Line failure detected. [SYS A FEPF] (not used for RST) K1/K2 byte invalid reception [SYS A] Transmitted K2 byte bit No.6 to 8 and received K2 byte bit No.6 to 8. [SYS A TDF] do not match (not used for RST) Received K2 byte bit No.5 not equal to 0 [SYS A TAF] (not used for RST) Transmitted K1 byte CH No. and received K1 byte CH No. [SYS A TDF] do not match (not used for RST) Lock-in control in operation [SYS B] Far end Protection Line failure/malfunction detected. [SYS B FEPF] (not used for RST) K1/K2 byte invalid reception [SYS B] Transmitted K2 byte bit No.6 to 8 and received K2 byte bit No.6 to 8. [SYS B TDF] do not match (not used for RST) Received K2 byte bit No.5 not equal to 0 [SYS B TAF] (not used for RST) Transmitted K1 byte CH No. and received K1 byte CH No. [SYS B TDF] do not match (not used for RST) Lock-in control in operation [SYS C] Far end Protection Line failure/malfunction detected. [SYS C FEPF] (not used for RST)

Status Indication Normal / Alarm Normal / Alarm In Service (Normal) / In Service (Abnormal) / Out Of Service (Maintenance) Off / On Normal / Alarm Off / On Normal / Alarm Normal / Alarm Normal / Alarm

MSP Control Disabled Unit Fail SYS A Lock-in SYS A Far End Protect Line Fail SYS A Protect SW Byte Fail SYS A Type Of Direction Fail

ST1 MJ ST2 MJ MJ MJ

SYS A Type Of Architecture Fail SYS A Channel Mismatch Fail

MJ MJ

Normal / Alarm Normal / Alarm

SYS B Lock-in SYS B Far End Protect Line Fail SYS B Protect SW Byte Fail SYS B Type Of Direction Fail

ST2 MJ MJ MJ

Off / On Normal / Alarm Normal / Alarm Normal / Alarm

SYS B Type Of Architecture Fail SYS B Channel Mismatch Fail

MJ MJ

Normal / Alarm Normal / Alarm

SYS C Lock-in SYS C Far End Protect Line Fail

ST2 MJ

Off / On Normal / Alarm

- 38 -

ROI-S06269

SYS C Protect SW Byte Fail SYS C Type Of Direction Fail

MJ MJ

K1/K2 byte invalid reception [SYS C] Transmitted K2 byte bit No.6 to 8 and receive K2 byte bit No.6 to 8. [SYS C TDF] do not match (not used for RST) Received K2 byte bit No.5 not equal to 0 [SYS C TAF] (not used for RST) Transmitted K1 byte CH No. and received K1 byte CH No. [SYS C TDF] (not used for RST) Lock-in control in operation [SYS D] Far end Protection Line failure/malfunction detected. [SYS D FEPF] (not used for RST) K1/K2 byte invalid reception [SYS D] Transmitted K2 byte bit No.6 to 8 and received K2 byte bit No.6 to 8. [SYS D TDF] do not match (not used for RST) Received K2 byte bit No.5 not equal to 0 [SYS D TAF] (not used for RST) Transmitted K1 byte CH No. and received K1 byte CH No. [SYS D TDF] do not match (not used for RST) Lock-in control in operation [SYS E] Far end Protection Line failure/malfunction detected. [SYS E FEPF] (not used for RST) K1/K2 byte invalid reception [SYS E] Transmitted K2 byte bit No.6 to 8 and received K2 byte bit No.6 to 8. [SYS E TDF] do not match (not used for RST) Received K2 byte bit No.5 not equal to 0 [SYS E TAF] (not used for RST) Transmitted K1 byte CH No. and receive K1 byte CH No. [SYS E TDF] do not match (not used for RST) Protection Line Signal Failure detected. [SYS A] Working Line Signal Failure detected. [SYS A] Protection Line Signal Degraded detected. [SYS A] Working Line Signal Degraded detected. [SYS A] APS Switching failure [SYS A] Exercise failure [SYS A] (not used for RST) Protection Line Online [SYS A] Working Line Online [SYS A] Wait To Restore status in operation [SYS A] Exercise [SYS A] (not used for RST) Protection Line Signal Failure detected. [SYS B] Working Line Signal Failure detected. [SYS B] Protection Line Signal Degraded detected. [SYS B] Working Line Signal Degraded detected. [SYS B] APS Switching failure [SYS B] Exercise failure [SYS B] (not used for RST) Protection Line Online [SYS B] Working Line Online [SYS B] Wait To Restore status in operation [SYS B] Exercise [SYS B] (not used for RST) Protection Line Signal Failure detected. [SYS C] Working Line Signal Failure detected. [SYS C] Protection Line Signal Degraded detected. [SYS C] Working Line Signal Degraded detected. [SYS C] APS Switching failure [SYS C] Exercise failure [SYS C] (not used for RST) Protection Line Online [SYS C] Working Line Online [SYS C] Wait To Restore status in operation [SYS C]

Normal / Alarm Normal / Alarm

SYS C Type Of Architecture Fail SYS C Channel Mismatch Fail SYS D Lock-in SYS D Far End Protect Line Fail SYS D Protect SW Byte Fail SYS D Type Of Direction Fail

MJ MJ ST2 MJ MJ MJ

Normal / Alarm Normal / Alarm Off / On Normal / Alarm Normal / Alarm Normal / Alarm

SYS D Type Of Architecture Fail SYS D Channel Mismatch Fail

MJ MJ

Normal / Alarm Normal / Alarm

SYS E Lock-in SYS E Far End Protect Line Fail SYS E Protect SW Byte Fail SYS E Type Of Direction Fail

ST2 MJ MJ MJ

Off / On Normal / Alarm Normal / Alarm Normal / Alarm

SYS E Type Of Architecture Fail SYS E Channel Mismatch Fail SYS A Protect Line SF SYS A Working Line SF SYS A Protect Line SD SYS A Working Line SD SYS A Switching Fail SYS A Exercise Fail SYS A Protect Online SYS A Working Online SYS A Local Wait To Restore SYS A Local Exercising SYS B Protect Line SF SYS B Working Line SF SYS B Protect Line SD SYS B Working Line SD SYS B Switching Fail SYS B Exercise Fail SYS B Protect Online SYS B Working Online SYS B Local Wait To Restore SYS B Local Exercising SYS C Protect Line SF SYS C Working Line SF SYS C Protect Line SD SYS C Working Line SD SYS C Switching Fail SYS C Exercise Fail SYS C Protect Online SYS C Working Online SYS C Local Wait To Restore

MJ MJ MJ MJ MN MN CR MJ ST2 ST2 ST2 ST2 MJ MJ MN MN CR MJ ST2 ST2 ST2 ST2 MJ MJ MN MN CR MJ ST2 ST2 ST2

Normal / Alarm Normal / Alarm Normal / Alarm Normal / Alarm Normal / Alarm Normal / Alarm Normal / Alarm Normal / Alarm Off / On Off / On Off / On Off / On Normal / Alarm Normal / Alarm Normal / Alarm Normal / Alarm Normal / Alarm Normal / Alarm Off / On Off / On Off / On Off / On Normal / Alarm Normal / Alarm Normal / Alarm Normal / Alarm Normal / Alarm Normal / Alarm Off / On Off / On Off / On

- 39 -

ROI-S06269

SYS C Local Exercising SYS D Protect Line SF SYS D Working Line SF SYS D Protect Line SD SYS D Working Line SD SYS D Switching Fail SYS D Exercise Fail SYS D Protect Online SYS D Working Online SYS D Local Wait To Restore SYS D Local Exercising SYS E Protect Line SF SYS E Working Line SF SYS E Protect Line SD SYS E Working Line SD SYS E Switching Fail SYS E Exercise Fail SYS E Protect Online SYS E Working Online SYS E Local Wait To Restore SYS E Local Exercising

ST2 MJ MJ MN MN CR MJ ST2 ST2 ST2 ST2 MJ MJ MN MN CR MJ ST2 ST2 ST2 ST2

Exercise [SYS C] (not used for RST) Protection Line Signal Failure detected. [SYS D] Working Line Signal Failure detected. [SYS D] Protection Line Signal Degraded detected. [SYS D] Working Line Signal Degraded detected. [SYS D] APS Switching failure [SYS D] Exercise failure [SYS D] (not used for RST) Protection Line Online [SYS D] Working Line Online [SYS D] Wait To Restore status in operation [SYS D] Exercise [SYS D] (not used for RST) Protection Line Signal Failure detected. [SYS E] Working Line Signal Failure detected. [SYS E] Protection Line Signal Degraded detected. [SYS E] Working Line Signal Degraded detected. [SYS E] APS Switching failure [SYS E] Exercise failure [SYS E] (not used for RST) Protection Line Online [SYS E] Working Line Online [SYS E] Wait To Restore status in operation [SYS E] Exercise [SYS E] (not used for RST)

Off / On Normal / Alarm Normal / Alarm Normal / Alarm Normal / Alarm Normal / Alarm Normal / Alarm Off / On Off / On Off / On Off / On Normal / Alarm Normal / Alarm Normal / Alarm Normal / Alarm Normal / Alarm Normal / Alarm Off / On Off / On Off / On Off / On

SYS A-E and SYS1-10 supportability NE mounting position and displayability on PNMTj
CTRL No SYS No SYS A SYS B SYS C SYS D SYS E CTRL 1,3,5,7 SYS 1 SYS 2 SYS 3 SYS 4 SYS 5 CTRL 2,4,6,8 SYS 6 SYS 7 SYS 8 SYS 9 SYS 10

- 40 -

ROI-S06269

3.5.8

CLK(W) Tab

The CLK(W) tab displays the status of the monitored CLK(W) items. This window only displays current settings and no control functions are available here.

Overview and description of the items monitored in the CLK

Module CLK

Item/Feature Unequipped Module Type Mismatch Unit Fail Service State

Severity MJ MJ MJ ST2 ST1 ST1

Description Not equipped with CLK is unequipped. No response from CLK to CTRL. Module type does not match. CLK unit failure. In Service (Normal) : In working order. In Service (Abnormal) : Occurred alarm of PM and/or DM. Out Of Service (Maintenance) : Maintenance item in operation. Indicates whether clock (CLK) is online (not used for RST) Indicates the selection of a clock from 2RACK or higher (not used for RST)

Status Indication Normal / Alarm Normal / Alarm Normal / Alarm In Service (Normal) / In Service (Abnormal) / Out Of Service (Maintenance) Off / On Off / On

CLK Online Slave CLK Selected

ST2 ST1

3.5.9

CLK(P) Tab

The same items are displayed for CLK(P) as for CLK(W).


(not used for RST)

- 41 -

ROI-S06269

3.5.10

OH/WS INTFC Tab

The OH/WS INTFC tab displays the status of the monitored OH/WS INTFC items. This window only displays current settings and no control functions are available here.

Overview and description of the items monitored in the OH/WS INTFC

Module

Item/Feature Unequipped Module Type Mismatch DSC MAIN F SYNC Unit Fail Service State

Severity MJ MJ MJ MJ ST2 ST1 ST1

Description Not equipped with OH/WS INTFC. No response from OH/WS INTFC to CTRL. Module type mismatch. Frame synchronization lost after being selected. OH/WS INTFC unit failure.OH/WS INTFC unit failure/malfunction. In Service (Normal) : In working order. In Service (Abnormal) : Occurred alarm of PM and/or DM. Out Of Service (Maintenance) : Maintenance item in operation. Protection channel is selected.[SYS C/D] (available when WS configuration of SYS C/D is 1+1). Protection channel is selected.[SYS A/B] Standby channel failure. [SYS C/D ] (occurs when ALM reception is set for the unused channels; available when WS configuration of SYS C/D is 1+1) Standby channel failure. [SYS A/B ] (occurs when ALM reception is set for the unused channels) TX side failure is detected on WS1.(Input signal loss, Output signal to MODEM module is lost) TX side failure is detected on WS2. (Input signal loss, Output signal to MODEM module is lost) *WS ch2 is available in 64QAM(1+1/1+0) and 128QAM(1+0) TX side failure is detected on WS3. (Input signal loss, Output signal to MODEM module is lost) *WS ch3 is available in 64QAM(1+0) TX side failure is detected on WS4. (Input signal loss, Output signal to MODEM module is lost) *WS ch4 is available in 64QAM(1+0) RX side failure is detected on WS1(loss of output signal condition). RX side failure is detected on WS2(loss of output signal condition). *WS ch2 is available in 64QAM(1+1/1+0) and 128QAM(1+0) RX side failure is detected on WS3 (Loss of output signal condition) *WS ch3 is available in 64QAM(1+0)

Status Indication Normal / Alarm Normal / Alarm Normal / Alarm Normal / Alarm In Service (Normal) / In Service (Abnormal) / Out Of Service (Maintenance) Off / On Off / On Normal / Alarm

PROT CH Selected(SYS C-D) PROT CH Selected(SYS A-B) STBY CH(SYS C-D)

ST2 ST2 MJ

STBY CH(SYS A-B)

MJ

Normal / Alarm

WS1 TX (SYS x-y) WS2 TX (SYS x-y)

MJ MJ

Normal / Alarm Normal / Alarm

WS3 TX (SYS x-y)

MJ

Normal / Alarm

WS4 TX (SYS x-y)

MJ

Normal / Alarm

MJ WS1 RX (SYS x-y) MJ WS2 RX (SYS x-y) MJ WS3 RX (SYS x-y)

Normal / Alarm Normal / Alarm

Normal / Alarm

- 42 -

ROI-S06269

MJ WS4 RX (SYS x-y) WS1 AIS Received (SYS x-y) ST1 ST1 WS2 AIS Received (SYS x-y) ST1 WS3 AIS Received (SYS x-y) ST1 WS4 AIS Received (SYS x-y) WS1 AIS Send (SYS x-y) ST1 ST1 WS2 AIS Send (SYS x-y) ST1 WS3 AIS Send (SYS x-y) ST1 WS4 AIS Send (SYS x-y)

RX side failure is detected on WS4 (Loss of output signal condition) *WS ch3 is available in 64QAM(1+0) AIS is received on WS1 channel. AIS is received on WS2 channel. *WS ch2 is available in 64QAM(1+1/1+0) and 128QAM(1+0) AIS is received on WS3 channel. *WS ch3 is available in 64QAM(1+0) AIS is received on WS4 channel. *WS ch4 is available in 64QAM(1+0) AIS is sent on WS1 channel. AIS is sent on WS2 channel. *WS ch2 is available in 64QAM(1+1/1+0) and 128QAM(1+0) AIS is sent on WS3 channel. *WS ch2 is available in 64QAM(1+0) AIS is sent on WS4 channel. *WS ch2 is available in 64QAM(1+0)

Normal / Alarm Off / On Off / On

Off / On Off / On Off / On Off / On

Off / On Off / On

Note: Depending on the NE configuration, some of the above items may not be displayed.

SYS A-D and SYS1-4, SYS6-9 supportability NE mounting position and displayability on PNMTj

CTRL No SYS No SYS A-B SYS C-D

CTRL 1,3,5,7,9,B,D SYS 1-2 SYS 3-4

CTRL 2,4,6,8,A,C SYS 6-7 SYS 8-9

- 43 -

ROI-S06269

Offline Tool, equipment interface supportability on PNMTj (for 64QAM)


CTRL No PNMTj WS No (WS 1+1) SYS A-B WS1 (WS 1+1) SYS A-B WS2 (WS 1+1) SYS C-D WS1 (WS 1+1) SYS C-D WS2 (WS 1+0) SYS A-B WS1 (WS 1+0) SYS A-B WS2 (WS 1+0) SYS A-B WS3 (WS 1+0) SYS A-B WS4 (WS 1+0) SYS C-D WS1 (WS 1+0) SYS C-D WS2 (WS 1+0) SYS C-D WS3 (WS 1+0) SYS C-D WS4 CTRL 1,3,5,7,9,B,D Offline Tool SYS 01,02 WS CH 1 SYS 01,02 WS CH 2 SYS 03,04 WS CH 1 SYS 03,04 WS CH 2 SYS 01,02 WS CH 1 SYS 01,02 WS CH 2 SYS 01,02 WS CH 3 SYS 01,02 WS CH 4 SYS 03,04 WS CH 1 SYS 03,04 WS CH 2 SYS 03,04 WS CH 3 SYS 03,04 WS CH 4 Equipment User Interface SYS1/2 WS DATA REG CH1 SYS1/2 WS DATA REG CH2 SYS 3/4 WS DATA REG CH1 SYS 3/4 WS DATA REG CH2 SYS 1/2 WS DATA REG CH1 SYS 1/2 WS DATA REG CH2 SYS 1/2 WS DATA PROT CH1 SYS 1/2 WS DATA PROT CH2 SYS 1/2 WS DATA REG CH1 SYS 1/2 WS DATA REG CH2 SYS 1/2 WS DATA PROT CH1 SYS 1/2 WS DATA PROT CH2 CTRL 2,4,6,8,A,C Offline Tool SYS 06,07 WS CH 1 SYS 06,07 WS CH 2 SYS 08,09 WS CH 1 SYS 08,09 WS CH 2 SYS 06,07 WS CH 1 SYS 06,07 WS CH 2 SYS 06,07 WS CH 3 SYS 08,09 WS CH 4 SYS 08,09 WS CH 1 SYS 08,09 WS CH 2 SYS 08,09 WS CH 3 SYS 08,09 WS CH 4 Equipment User Interface SYS 6/7 WS DATA REG CH1 SYS 6/7 WS DATA REG CH2 SYS 8/9 WS DATA REG CH1 SYS 8/9 WS DATA REG CH2 SYS 6/7 WS DATA REG CH1 SYS 6/7 WS DATA REG CH2 SYS 6/7 WS DATA PROT CH1 SYS 6/7 WS DATA PROT CH2 SYS 8/9 WS DATA REG CH1 SYS 8/9 WS DATA REG CH2 SYS 8/9 WS DATA PROT CH1 SYS 8/9 WS DATA PROT CH2

(for 128QAM)
CTRL No PNMTj WS No (WS 1+1) SYS A-B WS1 (WS 1+1) SYS C-D WS1 (WS 1+0) SYS A-B WS1 (WS 1+0) SYS A-B WS2 CTRL 1,3,5,7,9,B,D Offline Tool SYS 01,02 WS CH 1 SYS 03,04 WS CH 1 SYS 01,02 WS CH 1 SYS 01,02 WS CH 2 Equipment User Interface SYS1/2 WS DATA REG CH1 SYS 3/4 WS DATA REG CH1 SYS 1/2 WS DATA REG CH1 SYS 1/2 WS DATA PROT CH1 SYS 1/2 WS DATA REG CH1 SYS 1/2 WS DATA PROT CH1 CTRL 2,4,6,8,A,C Offline Tool SYS 06,07 WS CH 1 SYS 08,09 WS CH 1 SYS 06,07 WS CH 1 SYS 06,07 WS CH 2 SYS 08,09 WS1 SYS 08,09 WS2 Equipment User Interface SYS 6/7 WS DATA REG CH1 SYS 8/9 WS DATA REG CH1 SYS 6/7 WS DATA REG CH1 SYS 6/7 WS DATA PROT CH1 SYS 8/9 WS DATA REG CH1 SYS 8/9 WS DATA PROT CH1

(WS 1+0) SYS C-D WS1 (WS 1+0) SYS C-D WS2

SYS 03,04 WS1 SYS 03,04 WS2

- 44 -

ROI-S06269

3.5.11

CTRL Tab

The CTRL tab displays the status of the monitored CTRL items. This window only displays current settings and no control functions are available here.

Overview and description of the items monitored in the CTRL

Module CTRL

Item/Feature Unequipped Unit Fail Serial Bus Access Fail MDCPU Communication Service State

Severity MJ MJ MJ MJ ST2 ST1 ST1

Description CTRL is unequipped. No response from CTRL to LMS. CTRL unit failure. CTRL serial BUS access failure. Status of communication with MDCPU MODEM In Service (Normal) : In working order. In Service (Abnormal) : Occurred alarm of PM and/or DM. Out Of Service (Maintenance) : Maintenance item in operation. Alarm Correlation Status( Enable : Off, Disable : On ) Equipment is under maintenance. CTRL serial BUS protection switch status.

Status Indication Normal / Alarm Normal / Alarm Normal / Alarm Normal / Alarm In Service (Normal) / In Service (Abnormal) / Out Of Service (Maintenance) Off / On Off / On Off / On

Alarm Correlation Status Maintenance Bus Protect SW Status

ST1 ST1 ST1

- 45 -

ROI-S06269

3.5.12

MUX Tab

The MUX tab displays the status of the monitored MUX items. This window only displays current settings and no control functions are available here.

Overview and description of the items monitored in the MUX

Module MUX

Item/Feature Service State

Severity MJ ST2 ST1 ST1 MUX Summary Alarm

Description In Service (Normal) : In working order. In Service (Abnormal) : Occurred alarm of PM and/or DM. Out Of Service (Maintenance) : Maintenance item in operation.

Status Indication Normal / Alarm In Service (Normal) / In Service (Abnormal) / Out Of Service (Maintenance)

- 46 -

ROI-S06269

3.5.13

MODEM Tab

The MODEM tab displays the status of the monitored MODEM items. This window only displays current settings and no control functions are available here.

Overview and description of the items monitored in the MODEM

Module MODEM

Item/Feature Unequipped Module Type Mismatch Encode Fail Output Level Down Decode Fail F SYNC Loss XPIC REF CLK XPIC REF CLK Unlock MODEM CPU XPIC Out Of Frame Loss Of Frame Early Warning HOP High BER HOP Low BER Section High BER Section Low BER ATPC XPIC Control Input Level Down Service State

Severity MJ MJ MJ MJ MJ MJ MJ MJ MJ MJ MJ MJ MN MJ MN MJ MN MJ MJ MJ ST2 ST1 ST1

Description Not equipped with MODEM. No response from MODEM to CTRL. Module type mismatch. Loss of oscillator clock or asynchronization with VCO clock detected. Output level down detected at modulator. Clock anomaly detected after partial recovery Loss of radio frame detected. Clock anomaly detected in MODEM board set for XPIC usage An asynchronous reference between the master MODEM board and the slave MODEM board detected Anomalies detected in operation of MODEM CPU Input level down detected at cross-polarized demodulator. Out of frame detected. [from DMR side] Loss of frame (LOF) detected. [from DMR side] BER exceeded the specified threshold level (10E-8 to 10E-12) or Loss of radio frame between terminals. BER exceeded the specified threshold level (10E-4 to 10E-6) or Loss of radio frame detected in one hop. BER exceeded the specified threshold level (10E-6 to 10E-10) or Loss of radio frame detected in one hop. BER exceeded the specified threshold level (10E-4 to 10E-6) or Loss of radio frame between terminals. BER exceeded the specified threshold level (10E-6 to 10E-10) or Loss of radio frame between terminals. Anomaly detected in input determination for the ATPC control operation or the ATPC control signal. Signal discrepancy detected between control signals from recovery board set for XPIC usage Input level down detected at demodulator or receiver. In Service (Normal) : In working order. In Service (Abnormal) : Occurred alarm of PM and/or DM. Out Of Service (Maintenance) : Maintenance item in operation. Provisioning Status

Status Indication Normal / Alarm Normal / Alarm Normal / Alarm Normal / Alarm Normal / Alarm Normal / Alarm Normal / Alarm Normal / Alarm Normal / Alarm Normal / Alarm Normal / Alarm Normal / Alarm Normal / Alarm Normal / Alarm Normal / Alarm Normal / Alarm Normal / Alarm Normal / Alarm Normal / Alarm Normal / Alarm In Service (Normal) / In Service (Abnormal) / Out Of Service (Maintenance) Completed / Standby

Provisioning

ST1

- 47 -

ROI-S06269

Out Of Service(SW Position) IF Out Loopback Mode IF In Loopback Mode XPIC Reset AGC Stop Status

ST1 ST1 ST1 ST1 ST1

Front SW at position 1-F.(test mode) Normally at 0. Status when IF OUT Portis set to Loopback Mode Status when IF IN Portis set to Loopback Mode Input level down at cross-polarized demodulator detected or remote reset control detected. STATUS that reception AGC control of the TRP/SD unit is set to "stop" detected.

Off / On Off / On Off / On Off / On Off / On

- 48 -

ROI-S06269

3.5.14

OPT INTFC(W) Tab

The OPT INTFC tab displays the status of the monitored OPT INTFC items. This window only displays current settings and no control functions are available here.

Overview and description of the items monitored in the OPT INTFC

Module OPT INTFC

Item/Feature Unequipped Module Type Mismatch Out Of Frame On REG RS Trace(J0) Mismatch FM MUX RS Trace(J0) Mismatch FM DMR Loss Of Signal FM MUX Loss Of Frame FM MUX Signal Degrade(B1) FM MUX Loss Of Output TO MUX Loss Of Signal FM DMR Loss Of Frame FM DMR Excessive BER(B1) FM DMR Signal Degrade(B1) FM DMR Unit Fail Service State

Severity MJ MJ MJ MJ MJ MJ MJ MJ MJ MJ MJ MJ MN MJ ST2 ST1 ST1

Description Not equipped with OPT INTFC. No response from OPT INTFC to CTRL. Module type mismatch. Out of frame detected on Regular channel. Signal level mismatch between received value and expected value. [from MUX side]*1 Signal level mismatch between received value and expected value. [from DMR side]*1 Input signal loss (LOS: Loss of Signal) detected. [from MUX side] Loss of frame(LOF) detected. [from MUX Side] BER exceeded the specified threshold level (10E-5 to 10E-9). SD(B1) [from MUX side] Output signal loss detected. [to MUX side] Input signal loss (LOS: Loss of Signal) detected. [from DMR side] Loss of frame (LOF) detected. [from DMR side] BER exceeded the specified threshold level (10E-3 to 10E-5). EBER(B1) [from DMR side] BER exceeded the threshold level (10E-5 to 10E-9). SD(B1) [from DMR side] OPT INTFC unit failure. In Service (Normal) : In working order. In Service (Abnormal) : Occurred alarm of PM and/or DM. Out Of Service (Maintenance) : Maintenance item in operation. Out of frame detected on Protection channel. Hitless switch operation (Prot route selected) Inphase detected. Delay adjust monitor for hitless switch. Loop back operation status [MUX side] Loop back operation status [DMR side] Automatic Laser Shutdown is implemented.

Status Indication Normal / Alarm Normal / Alarm Normal / Alarm Normal / Alarm Normal / Alarm Normal / Alarm Normal / Alarm Normal / Alarm Normal / Alarm Normal / Alarm Normal / Alarm Normal / Alarm Normal / Alarm Normal / Alarm In Service (Normal) / In Service (Abnormal) / Out Of Service (Maintenance) Off / On Off / On Off / On Off / On Off / On Off / On Off / On

Out Of Frame On PROT HL SW OP Inphase Out REG Delay Matched With PROT Loop Back OP MUX Side Loop Back OP DMR Side ALS Implemented (*1)

ST1 ST2 ST2 ST2 ST1 ST1 ST1

Note *1: available when NE and its opposite counterpart are set to "Enable"

- 49 -

ROI-S06269

3.5.15

OPT INTFC(P) Tab

Same as OPT INTFC(W) Tab.

- 50 -

ROI-S06269

3.5.16

150M INTFC Tab

The 150M INTFC tab displays the status of the monitored 150M INTFC items. This window only displays current settings and no control functions are available here.

Overview and description of the items monitored in the 150M INTFC

Module 150M INTFC

Item/Feature Unequipped Module Type Mismatch Out Of Frame On REG RS Trace (J0) Mismatch FM MUX RS Trace (J0) Mismatch FM DMR Loss Of Signal FM MUX Loss Of Frame FM MUX Signal Degrade(B1) FM MUX Loss Of Output TO MUX Loss Of Signal FM DMR Loss Of Frame FM DMR Excessive BER(B1) FM DMR Signal Degrade(B1) FM DMR Unit Fail Service State

Severity MJ MJ MJ MJ MJ MJ MJ MJ MJ MJ MJ MJ MN MJ ST2 ST1 ST1

Description Not equipped with 150M INTFC. No response from 150M INTFC to CTRL. Module type mismatch. Out of frame detected on Regular channel. Signal level mismatch between received value and expected value. [from MUX side] *1 Signal level mismatch between received value and expected value. [from DMR side] *1 Input signal loss (LOS: Loss of Signal) detected. [from MUX side] Loss of frame (LOF) detected. [from MUX Side] BER exceeded the specified threshold level (10E-5 to 10E-9). SD(B1) [from MUX side] Output signal loss detected. [to MUX side] Input signal loss (LOS: Loss of Signal) detected. [from DMR side] Loss of frame (LOF) detected. [from DMR side] BER exceeded the specified threshold level (10E-3 to 10E-5). EBER(B1) [from DMR side] BER exceeded the threshold level (10E-5 to 10E-9). SD(B1) [from DMR side] OPT INTFC unit failure. In Service (Normal) : In working order. In Service (Abnormal) : Occurred alarm of PM and/or DM. Out Of Service (Maintenance) : Maintenance item in operation. Out of frame detected on Protection channel. Hitless switch operation (Prot route selected) Inphase detected. Delay adjust monitor for hitless switch. Loop back operation status [MUX side] Loop back operation status [DMR side]

Status Indication Normal / Alarm Normal / Alarm Normal / Alarm Normal / Alarm Normal / Alarm Normal / Alarm Normal / Alarm Normal / Alarm Normal / Alarm Normal / Alarm Normal / Alarm Normal / Alarm Normal / Alarm Normal / Alarm In Service (Normal) / In Service (Abnormal) / Out Of Service (Maintenance) Off / On Off / On Off / On Off / On Off / On Off / On

Out Of Frame On PROT HL SW OP Inphase Out REG Delay Matched With PROT Loop Back OP MUX Side Loop Back OP DMR Side

ST1 ST2 ST2 ST2 ST1 ST1

Note *1: available when NE and its opposite counterpart are set to "Enable"

- 51 -

ROI-S06269

3.5.17

DC-DC CONV Tab

The DC-DC CONV tab displays the status of the monitored MUX items. This window only displays current settings and no control functions are available here.

Overview and description of the items monitored in the DC-DC CONV

Module DC-DC CONV

Item/Feature Unequipped DC-DC CONV Service State

Severity MJ MJ ST2 ST1 ST1

Description Not equipped with DC-DC CONV No response from DC-DC CONV to CTRL. Unit Fail In Service (Normal) : In working order. In Service (Abnormal) : Occurred alarm of PM and/or DM. Out Of Service (Maintenance) : Maintenance item in operation.

Status Indication Normal / Alarm Normal / Alarm In Service (Normal) / In Service (Abnormal) / Out Of Service (Maintenance)

3.5.18

PS CONV Tab

Module PS CONV

Item/Feature Unequipped PS CONV Service State

Severity MJ MJ ST2 ST1 ST1

Description PS CONV is unequipped. No response from PS CONV to CTRL. Unit Fail In Service (Normal) : In working order. In Service (Abnormal) : Occurred alarm of PM and/or DM. Out Of Service (Maintenance) : Maintenance item in operation.

Status Indication Normal / Alarm Normal / Alarm In Service (Normal) / In Service (Abnormal) / Out Of Service (Maintenance)

- 52 -

ROI-S06269

3.6

MDP[01-05] Unit -SYS Detail


In the SYS Detail list, the monitoring status of each module in terms of specific systems (SYS) is displayed according to various tabs.

It can be launched by either of the following methods: After right-clicking the MDP icon in the Rack Summary, select [SYS] from the ensuing short cut menu.

After right-clicking the MDP icon in the Module Summary, select [MODULE] from the ensuing short cut menu.

- 53 -

ROI-S06269

3.6.1

MDP COMMON Tab

3.6.2

SYS** Tab

This status display shows only the SYS items selected via the tab; otherwise it is identical to the MODULE DETAIL feature.

3.7

MDP[06-10] Unit
The content displayed for the MDP 06-10 Unit is the same as for the MDP 01-05 Unit.

- 54 -

ROI-S06269

Line Unit
In the Line Unit, status monitoring and redundancy configuration setting/control can be performed.

4.1

Line Summary
The Line Summary view displays the switch status for redundancy configuration. The respective display is different for N+1, HotStandby, and Twinpath.

For N+1

For Hot Standby:

For Twinpath:

- 55 -

ROI-S06269

4.2

Line Detail
The Line Detail window shows the details for the redundancy switch functions. The respective display is different for N+1, HotStandby, and Twinpath.

For N+1

- 56 -

ROI-S06269

For Hot Standby:

For TwinPath:

- 57 -

ROI-S06269

4.2.1

REGxx tab

Module REGxx

Item/Feature Switching Control TX Side

Severity

Description Forced: Not switched in any condition. Manual: Not switched except alarm Auto : Switched by alarm

Status Indication Forced Switch-Work / Forced Switch-Prot / Manual Switch-Work / Manual Switch-Prot / Auto Forced Switch-Work / Forced Switch-Prot / Manual Switch-Work / Manual Switch-Prot / Auto Restart / Stop Restart / Stop Off / On Off / On Off / On Off / On Off / On Off / On Off / On Off / On Off / On Off / On Normal / Alarm Normal / Alarm Normal / Alarm Normal / Alarm Off / On Off / On Normal / Alarm Normal / Alarm Normal / Alarm Normal / Alarm Auto / Manual Off / On Normal / Alarm Normal / Alarm Off / On Off / On Normal / Alarm Normal / Alarm Normal / Alarm Off / On Off / On Off / On Off / On Off / On Off / On

Switching Control RX Side Forced: Not switched in any condition. Manual: Not switched except alarm Auto : Switched by alarm Recovery Operation Exercise Operation Counter Operation LockOut PROT Forced PROT Manual PROT LockOut REG Forced REG Manual REG Disable Operation TX Test Operation COM Auto Exerciser Stop COM Counter Stop SWO Fail SC Fail DSC A DSC B DSC A Selected DSC B Selected TR DIST1 I/F TR DIST2 I/F TR DIST3 I/F TR DIST4 I/F SWO Priority Manual SWO PROC Maintenance PPF Service Fail PROT TX SW Complete PROT Recovery PROT Early Warning PROT BER PROT F SYNC PROT RX ACS SW Answer TX ACS SW Answer Lockout OP STS Forced ACS SW OP STS Manual ACS SW OP STS TX SW Complete I PROT ST1 ST1 MJ MJ MJ MJ ST2 ST2 MJ MJ MJ MJ ST1 ST1 MJ CR ST1 ST1 MJ MJ MJ ST1 ST1 ST1 ST1 ST1 ST1 Alarm Recovery acknowledgment control. Exerciser control. Controls the counter function operation. Control to inhibit switchover of the all line. RX Access Switch control.(Forced mode) RX Access Switch control.(Manual mode) Control to inhibit switchover of the line. Hitless Switch control.(Forced mode) Hitless Switch control.(Manual mode) Control to inhibit automatic switchover of the line. Remote station Tx SW control. Automatic exerciser stops. Protection channel counter stops. Protection switchover execution fails. Associated control line is broken. Control line (DSC) #A fails. Control line (DSC) #B fails. Control line (DSC) #A is selected. Control line (DSC) #B is selected. Data signal associated with the TR DIST fails. Data signal associated with the TR DIST fails. Data signal associated with the TR DIST fails. Data signal associated with the TR DIST fails. Switchover priority is set in Auto < Manual. Indicates it is under maintenance. Protection channel alarm continues over the specified period. (Prolonged Protection Failure/malfunction) Protection channel selection has provided, but there is no response. [PROT] TX SW ANS from the opposite TX station is confirmed. [PROT] Some alarm events have occurred and then cleared all of them. [PROT] Early warning has occurred. [PROT] Bit error rate ALM has occurred. [PROT] Frame synchronous ALM has occurred. [PROT] RX access sw response is confirmed. [PROT] TX access sw response is confirmed. [PROT] Under lockout operation. [PROT] Protection channel is forced to switch by the FORCED operation. [PROT] Protection channel is switched by the manual operation. [PROT] TX SW ANS from opposite TX station is continuously confirmed for a specified interval. [PROT]

- 58 -

ROI-S06269

EARLY Warning I PROT BER I PROT FSYNC I PROT Disable OP STS TX Test OP STS Manual Exerciser PSWO REG

MJ MJ MJ ST1 ST1 ST1 ST1

Early warning continued at a specified interval. [PROT] Bit error ALM has occurred for a specified interval. [PROT] Frame synchronous ALM occurred for a specified interval. [PROT] Automatic switching is inhibited with control operation. [REG] The test condition in Parallel transmission is set by control operation. [REG] Exerciser is manually executed. [REG] Regular channel has automatically switched to protection channel for a specified interval. (Prolonged Switchover) [REG] Select control for regular channel has provided, but there is no response. [REG] Synchronization of regular channel traffic has not established in the protection channel during the switching over operation and going back operation. [REG] Some alarm events have occurred and then cleared all of them. [REG] Early warning has occurred. [REG] Bit error rate ALM has occurred. [REG] Frame synchronous ALM has occurred. [REG] Hit less switch response is confirmed. [REG] TX switch response is confirmed. Hitless switching control is executed manually. [REG] Under the LOCKOUT operation. [REG] Regular channel is forced to switch by FORCED operation. [REG] ALM events are detected during the Exerciser execution. [REG] Exerciser ALM has occurred in the caused of Timing ALM. [REG] Exerciser is executed, ALM is then detected. [REG] Exerciser ALM has occurred in the caused of excluding Timing ALM. [REG] Turned to WAIT by Exerciser execution. [REG] Timing ALM is detected during a specified interval. [REG] Early warning has occurred during a specified interval. [REG] Bit error rate ALM has occurred during a specified interval. [REG] Frame synchronous ALM has occurred during a specified interval. [REG] Hit less switch response is confirmed during a specified interval. [REG] TX switch response is confirmed during a specified interval.[REG]

Normal / Alarm Normal / Alarm Normal / Alarm Off / On Off / On Off / On Off / On

ServiceFail REG Timing REG

CR MJ

Normal / Alarm Normal / Alarm

Recovery REG Early Warning REG BER REG F SYNC REG HL SW Answer TX SW Answer Manual SW OP STS Lockout OP STS Forced SW OP STS Exerciser Init TX Exerciser TIM Exerciser RST TX Exerciser Other Exerciser Wait Timing I REG Early Warning I REG BER I REG F SYNC I REG HL SW Answer I TX SW Answer I

ST1 MJ MJ MJ ST1 ST1 ST1 ST1 ST1 MJ MJ MJ MJ ST1 MJ MJ MJ MJ ST1 ST1

Off / On Normal / Alarm Normal / Alarm Normal / Alarm Off / On Off / On Off / On Off / On Off / On Normal / Alarm Normal / Alarm Normal / Alarm Normal / Alarm Off / On Normal / Alarm Normal / Alarm Normal / Alarm Normal / Alarm Off / On Off / On

- 59 -

ROI-S06269

4.2.1.1

Recovery (Rcvy) Operation

Alarm Recovery (RCVY) acknowledgment control. When the Execute button is clicked, the PROT or REGn channel RCVY symbol changes to green. This means that alarm Recovery has been confirmed.

1. 2. 3.

Click the [Recovery Operation] button in the LINE Detail window. Click the [Execute] button to execute control. After completion, click the [Close] button.

4.2.1.2

Excercise

Automatic Exerciser control. Select the exerciser control to be performed then click on the Execute button:

1. 2.

Click the [Exercise Operation] button in the LINE Detail window. Manual Exercise, Auto Exercise Stop or Auto Exercise Restart is selected from the radiobutton in the Exercise Operation column. Auto Exercise Stop : Stops the Automatic Exerciser. Auto Exercise Restart : Restarts the Automatic Exerciser. The Auto Exerciser status indicator changes to Green when the Exerciser has restarted.

- 60 -

ROI-S06269

3. 4.

Click the [Execute] button to execute control. After completion, click the [Close] button.

4.2.1.3

Counter Operation

Controls the counter function operation.

To Initialize the counter.: 1. 2. 3. 4. Click the [Exercise Operation] button in the LINE Detail window. Check the Reset check box in the Counter Operation column. Click the [Execute] button to execute control. After completion, click the [Close] button.

When you begin/stop the counter 1. Click the [Counter Operation] button in the LINE Detail window. 2. Select the Counter control to be performed
Stop : Stops the counter. Restart : Restarts the counter.

3. Click the [Execute] button to execute control. 4. After completion, click the [Close] button.

- 61 -

ROI-S06269

4.2.1.4

Switch Over Operation

Switch control.

1. 2. 3.

Click the [LockOut], [Forced], or [Manual] button in the LINE Detail window. With the radio button in the Select Switch Mode column, select LockOut, Forced, or Manual Switch Over Operation column, select On(configure the mode for the content to be selected in the Select Switch Mode column) or Off(quit the mode for the content to be selected in the Select Switch Mode column). Click the [Execute] button to execute control. After completion, click the [Close] button.

4. 5.

- 62 -

ROI-S06269

4.2.1.5

Disable Operation

Control to inhibit automatic switchover of the line.

1. 2.

Click the [Disable Operation] button in the LINE Detail window. With the radio button in the Disable Operation column, select On or Off. ON : Inhibits automatic switchover. OFF : Enables automatic switchover.

3. 4.

Click the [Execute] button to execute control. After completion, click the [Close] button.

- 63 -

ROI-S06269

4.2.1.6

TX Test Operation

Remote station Tx SW control.

1. 2.

Click the [TX Test Operation] button in the LINE Detail window. With the radio button in the TX Test Operation column, select On or Off. ON : Manually switches the Tx SW at the remote station. OFF : Releases switchover operation of the Tx SW at the Remote station.

3. 4.

Click the [Execute] button to execute control. After completion, click the [Close] button.

- 64 -

ROI-S06269

EXTERNAL DI/DO
DI/DO item Setup/control is executed in the item status monitoring display.

5.1

External DI/DO Detail


In the External DI/DO Detail window, the respective items can be displayed using the DI and DO tabs.

The External DI/DO Detail window can be displayed by the following means: Click on the [External DI/DO] icon in the Others column.

- 65 -

ROI-S06269

5.1.1

DI Tab

The DI Tab Provides a list of DI configuration/control items.

DI Window

Item/Feature
Input-x

Description
DI input configuration

Specific conditions for it to be displayed/configured


none

- 66 -

ROI-S06269

5.1.2

DO Tab

The DO Tab Provides a list of DO configuration/control items.

DO Window

Item/Feature
Output-x Latch Output Pulse Output

Description
DO output configuration Latch output execution Pulse output execution

Specific conditions for it to be displayed/configured


none Only when the Output Pattern is set to "Latch" Only when the Output Pattern is set to "Pulse"

- 67 -

ROI-S06269

5.1.2.1

External DI Configuration The detailed DI configuration is performed via the External DI Configuration window.

1. 2.

Click the [Input-n] button in the DI Window. Input items are displayed in the following window.

5.1.2.1.1 1. 2.

Setting the Selected Input to Alarm or Status

Enter the desired name of the selected input in the Name field. A maximum of 32 characters can be used. Select the desired input condition in the Condition section. You can select from the following two (2) choices such as the alarm is reported when Event ON (the selected input terminal is closed loop condition) or the alarm is reported when Event OFF (the selected input terminal is open condition). Enter the status strings corresponding to the input condition in the Event ON and Event OFF field in the Status Strings section. A maximum of 32 characters can be used. The alarm input severity is defined in the ITU-T X.733 Recommendation. Select the description of the Severity, Alarm Type and Probable Cause fields in the X.733 section by clicking the pull-down arrow ( ) on the right-hand side of the selection field. Click [Execute] button to save the selected settings of the device. Click [Close] button when finished.

3. 4.

5. 6.

- 68 -

ROI-S06269

5.1.2.2

External DO Configuraion

The detailed DO configuration is performed in the External DO Configuration window. 1. 2. Click the [Output-n] button in the DO Window. Input items. are displayed in the following window:

5.1.2.2.1 1. 2. 3. 4. 5.

Configuration of Output Signal Type and Status String

Enter the desired name of the selected input in the Name field. A maximum of 32 characters can be used. Select from Normal or the desired Invert Polarity in the Polarity column. In the Output Pattern Column An output pattern is selected from Pulse 100ms, Pulse 1s, Pulse 10s, or Latch by clicking the arrow. When Pulse is selected as Output Pattern, input arbitrary character strings in the Pulse column of the Status Strings column not exceeding 32 characters. When Latch is selected as Output Pattern, input the character string corresponding to the field of Event ON of the Status Strings column, and Event OFF as the input status not exceeding 32 characters. Click the [Execute] button and save a configuration. After completion, click the [Close] button.

6. 7.

- 69 -

ROI-S06269

5.1.2.3

External DO Control(Pulse)

The DO pulse output is initiated in the External DO Control (Pulse) window.

Initiating pulse output: 1. 2. 3. Click the [Pulse Output-n] button in DO window. Click and perform the [Execute] button. After completion, click the [Close] button.

- 70 -

ROI-S06269

5.1.2.4

External DO Control(Latch)

DO Latch output can be initiated from the External DO Control (Latch) window.

Initiating latch output: 1. 2. Click the [Latch Output-n] button in DO window. With the radio button at the lowermost part of the Latch column, Event On or Event Off is selected. LMS relay output configuration Polarity setting Normal Invert 3. 4. Click [Execute] button to initiate. After completion click the [Close] button. LMS relay output Event On Event Off close open open close

- 71 -

ROI-S06269

SYSTEM MAINTENANCE
In System Maintenance, functions, such as Maintenance configuration to download/upload equipment configuration files / program files, modular reset, CTRL, and SWO PROC, are available.

6.1

System Maintenance Detail


The list of system related functions is displayed in the System Maintenance Detail window.

It is displayed as follows. Select [Configuration]-[System Maintenance] in NE-Specific Menu Bar.

- 72 -

ROI-S06269

6.1.1

System Maintenance
Item/Feature Description Denotes the individual Network Element Denotes the IP Address Denotes the MAC Address Denotes the IP Address of Opposite NE1 Denotes the IP address of the Opposite NE2 Denotes the IP Address of Opposite NE3 Denotes the IP Address of Opposite NE4 Denotes an explanatory/cautionary note pertaining to Network Elements Denotes a Configuration File download Denotes a System Parameter File download Denotes a module Parameter File download Denotes download of the indicated program file Denotes download of the indicated program file Denotes download of the indicated program file Denotes CPU module reset Denotes CPU module reset Denotes a Configuration File Upload System Parameter File Upload Denotes the time and date setting Denotes the Network Settings for the various NEs Denotes Maintenance of the respective Control (CTRL) Specific conditions for it to be displayed/configured Only the number of CTRL Modules that exist in the device composition is displayed. Only the number of SWO PROC Modules that exist in the equipment configuration is displayed.

NE Name IP Address MAC Address Opposite-1 IP Address Opposite-2 IP Address Opposite-3 IP Address Opposite-4 IP Address Note Configuration File DL System Parameter File DL System Parameter File (Module unit) Program File (MODEM/TRP/SD/2SD) Program File (LMS/CTRL/SWO PROC) Program File (All SYS under CTRL) CPU Reset (LMS/CTRL/SWO PROC) CPU Reset (MODEM/TRP/SD/2SD) Configuration File UL System Parameter File UL Date/Time Equipment Network Setting CTRLxx Maintenance

SWO PROCxx Maintenance

Denotes the Maintenance of SWO PROC

- 73 -

ROI-S06269

6.1.1.1

Note

It is possible to input arbitrary character strings (not exceeding 100 characters) as a note.

Note Configuration: 1. 2. 3. 4. Click the [Note] button in the System Maintenance window. Input arbitrary character strings (not exceeding 100 characters) in the text field of the Note column within 100 characters. By clicking the [Execute] button, the inputted content is saved in the NE. After completion click the [Close] button will be clicked if an input is completed.

6.1.1.2

Download Configuration File(Network Config/MIB Config)

This function is used to download the network configuration files from the PNMT to the Control module. The network configuration file 5S_network.cfg, contains the IP address of the target NE and the information about the network where the target NE is located. The MIB.cfg file contains relevant information about the equipment (i.e. name, pm type, etc.) and housekeeping (External DI/DO). *This window is not available when MAINT is OFF. To download the new configuration file to the CTRL: 1. Click [DL Configuration File] button in System Maintenance window.

2.

Select the type of file to be downloaded in the Type list.

- 74 -

ROI-S06269

3.

Enter the location of the configuration file in the File field, or click [Browse] to locate the file on the local hard disk or diskette. WARNING!!!

Make sure that the correct configuration file is downloaded to the correct Control module. An incorrect configuration file may lead to Control module or network malfunction/failure.
Click the [Execute] button to start the operation. A message window indicating the status of the operation will appear. It will close automatically once the operation is finished. WARNING!!!

Make sure that you have successfully downloaded the configuration file before executing Update. Otherwise the Control module will switch to an empty ROM that may cause Control module malfunction/failure.
4. Click the [Update] button to activate and save the new configuration file(s).

5.

Select the appropriate box for the type of configuration file that is to be updated. One or more configuration file(s) can be updated by checking the selection box of the configuration file name. Click [Execute] to start the operation. The "with ROM (CTRL Program) Switching" box is for switching to the ROM with the new CTRL Program and has the same function that was previously described in section 2.16.5 Downloading a new Program file to the Control Module. NOTE When updating the 5S_network.cfg file, NE-to-NE communication will be lost when the Control module reinitialises to the new system configuration. This WILL NOT affect the wireless link. During this time PNMT connection to the NE will be lost but will automatically be restored after the Control module is reset.

6.

Click the [Close] button when done.

- 75 -

ROI-S06269

6.1.1.3

Download Configuration File(System Parameter Config)

System Parameter files for all NEs can be downloaded all at once.

Downloading : 1. 2. Click [DL System Parameter File] in System Parameter window. Enter the location of the configuration file in the File field, or click [Browse] to locate the file on the local hard disk or diskette. WARNING!!!

Make sure that the correct configuration file is downloaded to the correct NE. An incorrect configuration file may lead to NE or network malfunction/failure.
3. Click the [Execute] button to start processing.

After downloading the System Parameters, although a CTRL module and a SWO PROC module are reset automatically, a LMS module will be in the state of the waiting for reset. Since a Reset Control window will open if the [CPU Reset] button is clicked, it is possible to perform Reset of LMS module from here. WARNING!!!

Downloaded System Parameter config is only activated after the module is reset.
4. After downloading is completed, click the [Close] button to close the window.

NOTE

After individual download to LMS Module is executed, it is necessary to perform batch download from this window once using the procedure from 6.1.1.4 when the configured number of CTRL Modules and SWO PROC Module are changed (by downloading the System Parameter File).

- 76 -

ROI-S06269

6.1.1.4

Download Configuration File(System Parameter Config) System Parameter files can be individually downloaded to LMS, CTRL, or SWO PROC.

Downloading : 1. 2. 3. Click [DL System Parameter (Module unit)] in the System Maintenance window. Select LMS, CTRL, and SWO PROC1 or SWO PRCO2 in the LMS/CTRL/SWO PROC column. When CTRL is selected, specify a Rack number and a CTRL number in the CTRL Select column.

Input a path into the text field of the File column, or click the [Browse] button, and specify the file on a disk. WARNING!!! Make sure that the correct program file is downloaded to the Control module. Incorrect program files are liable to cause malfunction Click the [Execute] button to start processing. NOTE This operation may take several minutes depending on the program file size. 4. Since the LMS module will be in a standby state waiting for reset when LMS is selected, click the [CPU Reset] button to display the Reset Control window, and then reset the LMS. After downloading is completed, click the [Close] button to close the window.

5.

- 77 -

ROI-S06269

6.1.1.5

Download Program File (CTRL subfile - individual) To certain specific SYS, MODEM, TRP and SD, or 2SD designated programs can be downloaded.

Downloading : 1. 2. Click [DL Program File (MODEM/TRP/SD/2SD)] in System Maintenance window. Specify RACK number and SYS number in the Location Select column.

Input a path into the text field of the File column, or click the [Browse] button, and specify the file on a disk. WARNING!!! Make sure that the correct program file is downloaded to the Control module. Incorrect program files are liable to cause malfunction 3. [Click the [Execute] button to start processing. NOTE This operation may take several minutes depending on the program file size. 4. After downloading is completed, click the [Close] button to close the window.

- 78 -

ROI-S06269

6.1.1.6

Download Program File Programs can be downloaded to LMS, CTRL, or SWO PROC module.

Downloading : 1. 2. 3. 4. Click [DL Program File (LMS/CTRL/SWO PROC)] in System Maintenance window. Select LMS, CTRL, and SWO PROC01 and SWO PROC02 in the LMS/CTRL/SWO PROC column. When LMS is selected, Main or Boot are also selected. When CTRL is selected, select Program or Database and select RACK number and CTRL number from the CTRL Select column is also selected.

Input a path into the text field of the File column, or click the [Browse] button, and specify the file on a disk. WARNING!!! Make sure that the correct program file is downloaded to the Control module. Incorrect program files are liable to cause malfunctions. 5. [Click the [Execute] button to start processing. NOTE This operation may take several minutes depending on the program file size. 6. After downloading is completed, click the [Close] button to close the window.

- 79 -

ROI-S06269

6.1.1.7

Download Program File

Programs from alll modules [ of a certain CTRL subfile ] of all SYS(s) can be downloaded to MODEM, TRP and SD, or 2SD.

Downloading. 1. 2. Click [DL Program File (MODEM/TRP/SD/2SD)] in System Maintenance window. Specify RACK Number and CTRL Number in the Location Select Column.

A path is inputted into the text field of the File column, or the [Browse] button is clicked, and the file on a disk is specified. WARNING!!! Make sure that the correct program file is downloaded to the Control module. Incorrect program files are liable to cause malfunction 3. Click the [Execute] button to start processing. NOTE This operation may take several minutes depending on the program file size. 4. After downloading is completed, click the [Close] button to close the window.

- 80 -

ROI-S06269

6.1.1.8

CPU Reset(LMS/CTRL/SWO PROC) By selecting either LMS, CTRL, and SWO PRCO the module is reset.

Resetting: 1. 2. 3. 4. 5. Click [CPU Reset (LMS/CTRL/SWO PRC)] in a System Maintenance window. Select the module which carries out reset LMS, CTRL, and from SWO PROC01 and SWO PROC02 in the LMS/CTRL/SWO PRCO column. If a check is put into a "with ROM (Program) switching" check box when LMS is selected, bank will be changed after downloading. When CTRL is selected, select a RACK number and a CTRL number from the CTRL Select column, and specify the CTRL module which resets. Click the [Execute] button and perform reset. NOTE When LMS is selected, connection with NE goes out for several minutes. When CTRL or SWO PROC is selected, connection between LMS~CTRL/SWO PROC goes out for several minutes. 6. After completion, click the [Close] button to close the window.

- 81 -

ROI-S06269

6.1.1.9

CPU Reset(MODEM/TRP/SD/2SD)

It resets to a certain MODEM of SYS, TRP, or SD/2SD.

Resetting: 1. 2. 3. 4. Click [CPU Reset (MODEM/TRP/SD/2SD)] from a System Maintenance window. Select from MODEM/TRP/SD / 2SD columns the classification of the module which resets by specifying MODEM, TRP, or SD/2SD. Specify a RACK number and a SYS number in the Location Select column, and select SYS which resets. Click the [Execute] button and perform reset. NOTE The main signal is turned off when this operation is carried out. 5. After completion, the [Close] button will be clicked and a window will be closed.

- 82 -

ROI-S06269

6.1.1.10 Upload Configuration File This function is used to upload the configuration file from the Control module of the selected NE to the PNMT PC. To upload the configuration file from the Control module to the PNMT: 1. Click the [UD Configuration File] button in System Maintenance window.

2. 3. 4. 5. 6. 7.

Select the type of file to be uploaded in the Type field. Enter the desired file name for the uploaded file. And select and the directory where the uploaded file is to be saved. Click the [Execute] button to start the operation. A message window indicating the status of the operation will appear. It will close automatically once the operation is completed. After the upload is finished, click the [Close] button. Verify that the file was uploaded to the specified directory.

- 83 -

ROI-S06269

6.1.1.11 System Parameter One module of LMS, CTRL, and SWO PROC is selected, and a System Parameter file is uploaded.

Uploading 1. 2. 3. 4. 5. Click the [ULSystem Parameter File] button in System Maintenance window. Select the module for upload from the LMS/CTRL/SWO PROC column. When CTRL is selected, select a RACK number and a CTRL number from the CTRL Select column, and specify CTRL for upload. Click the [Execute] button to start the operation. After the upload is finished, click the [Close] button.

- 84 -

ROI-S06269

6.1.1.12 Date/Time The Date and Time stored in Control module can be displayed and adjusted using this function. To set the Date/Time: 1. Click the [Date/Time] button in the System Maintenance window. NOTE To synchronize the Date and Time field values with those of the PNMT computer, click the Display PC Time box (placing a checkmark in it).

2.

To check the Date and Time Settings of the Control module: 1) Select Get Date/Time in the Date/Time window. 2) Click [Execute] button. 3) The current date and time in the Control module will be displayed in the Date and Time field.

3.

To set the Date and Time on the Control module: 1) Select Set Date/Time in the Date/Time window. 2) Click [Execute] button. 3) Click [Close] button when done.

- 85 -

ROI-S06269

6.1.1.13 Equipment Network Setting In order to operate Auto Discovery and Network function respectively to PNMS and PNMT it is necessary in advance, connect PNMT to each equipment to set Network information This function is used to configure the equipment network settings (i.e. IP and routing addresses, subnet masks) using the tags in the lefthand field of the Equipment Network Settings window of the selected NE for the PNMT PC.

For detail refer to Appendix A.

- 86 -

ROI-S06269

6.1.1.14 MAINT Configuration/release in Maintenance mode are performed to CTRL or a SWO PROC module.

The Maintenance mode setting: 1. 2. 3. 4. Click [CTRL** Maintenance] or [SWO PROC** Maintenance] button of System Maintenance window. Select on ON/OFF depending on desired state. Click the [Execute] to implement the command. Click the [Close] button when finished.

- 87 -

ROI-S06269

7
7.1

PROVISIONING
MENU
Following items are prepared for detail setting
UNIT TRP MODULE TRP ITEM RSL for TCS ATPC TX Minimum Level ATPC TX Maximum Level ATPC Alarm Action ATPC RSL Threshold Level Encoding Law OOW, EOW, GRP Call No. Encoding Law OOW CH1-4 EOW CH1-4 CLK Mode CH2 Interface Select Line Priority Sending End Line Receiving End Line Manual Switching Switch-Over Mode Counter Setting at Manual Switching PSWO Alarm Waiting Timer PPF Alarm Watiting Timer Excerciser Start Timer Excerciser Cycle SYS 1-5 Lock-in Mode Usage Count Detect Time Hold Time Signal Fail (P) Priority Auto Exerciser Signal Degrade Usage (No Items in RST mode) Alarm Correlation CTRL External DO Configuration HOP High BER Alarm (50% Activation) Section Low BER Alarm (50% Activation) Section High BER Alarm (50% Activation) Early Warning (50% Activation) PMON SES Threshold Error Pulse Selection Signal Degraded(B1) from MUX / DMR Excessive BER(B1) from MUX DMR Automatic Laser Shutdown Section Trace (J0) Mode (Fm/To MUX / DMR) J0 Select (Fm/To MUX / DMR) Transmit Pattern (Fm/To MUX / DMR) Expected Pattern (Fm/To MUX / DMR) Monitor Requirement (Fm/To MUX / DMR) PMON SES Threshold

MDP

OW DIG HYB

SWO PROC

BB SW CTRL

CLK CTRL MODEM

OPT INTFC/ 150M INTFC

- 88 -

ROI-S06269

7.2
7.2.1

SETTING METHOD
METHOD-1: Common setting to all SYS

1. Select "Configuration" - "Provisioning" - "No.X" - "TRP-MODULE" or "MDP[XX-XX]MODULE" from NE Specific Menu Bar, then the following "MODULE Detail" window appears. 2. Select the MODULE Tab, and click the Item button, then the following Provisioning window appears. 3. Select the parameter, or input the value, and click "Execute" button, then repeat for applicable items.

7.2.2

METHOD-2: Independent setting to each SYS

1. Select "Configuration" - "Provisioning" - "No.X" - "TRP-SYS" or "MDP[XX-XX]-SYS" from NE Specific Menu Bar, then the following "SYS Detail" window appears. 2. Select the SYS Tab, and click the Item button, then the following Provisioning window appears.(same window as above) 3. Select the parameter, or input the value, and click "Execute" button, then repeat for applicable items.

Example case for moving to TRP Provisioning window

- 89 -

ROI-S06269

Example case for moving to MDP Provisioning window

- 90 -

ROI-S06269

7.3
7.3.1

DETAILS
Transmitter and Receiver

UNIT TRP

MODULE TRP

ITEM RSL for TCS ATPC TX Minimum Level ATPC TX Maximum Level

DESCRIPTION Receive Signal Level threshold for starting the Threshold Crossed Second counting Minimum TX level threshold for ATPC level decrease control from opposite equipment Maximum TX level threshold for ATPC level increase control from opposite equipment TX level control method during the ATPC alarm condition Receive Signal starting the ATPC Level threshold for

PARAMETER -70 to -40 dBm Nominal Level -20 to 0 dB Nominal Level -20 to 0 dB

ATPC Alarm Action ATPC RSL Threshold Level

MIN / MAX / HOLD -70 to -40 dBm

NOTE *1: ATPC TX Minimum Level < ATPC TX Maximum Level

- 91 -

ROI-S06269

7.3.2

Orderwire

UNIT MDP

MODULE OW

ITEM Encoding Law OOW EOW GRP

DESCRIPTION Pulse code modulation law Ominibus Orderwire Calling No. Express Orderwire Calling No. Group Orderwire Calling No.

PARAMETER A-Law / u-Law NNN (3 digit basis) NNN (3 digit basis) NNN (3 digit basis)

- 92 -

ROI-S06269

7.3.3

Orderwire Digital Hybrid

UNIT MDP

MODULE DIG HYB

ITEM Encoding Law OOW CH1 OOW CH2 OOW CH3 OOW CH4 EOW CH1 EOW CH2 EOW CH3 EOW CH4 CLK Mode CH2 Interface Select

DESCRIPTION Pulse code modulation law OOW digital hybrid port 1 (Clock mode:Master/Slave, External port) OOW digital hybrid port 2 (Clock mode:Slave, MUX direction port) OOW digital hybrid port 3 (Clock mode:Slave, DMR direction port) OOW digital hybrid port 4 (Clock mode:Master, OW module port) EOW digital hybrid port 1 (Clock mode:Master/Slave, External port) EOW digital hybrid port 2 (Clock mode:Slave, MUX direction port) EOW digital hybrid port 3 (Clock mode:Slave, DMR direction port) EOW digital hybrid port 4 (Clock mode:Master, OW module port) Clock mode for OOW/EOW digital hybrid port 1 Switching the Port2 interface

PARAMETER A-Law / u-Law Used / Not Used Used / Not Used Used / Not Used Used / Not Used Used / Not Used Used / Not Used Used / Not Used Used / Not Used Master / Slave Internal / External

- 93 -

ROI-S06269

7.3.4

Radio Protection Switchover for N+1 Configuration

UNIT MDP

MODULE SWO PROC

ITEM Line Priority Sending End Line Receiving End Line

Manual Switching

DESCRIPTION Line priority for switching to protection channel (Auto Switching Mode) Transmission is available Reception is Available Define whether or not manual switchover execution is included when the automatic protection switching has been performed by generating the PSWO alarms. Switchover control priority Manual switching counting Switchover alarm delay time Protection failure alarm delay time Periodic automatic switching test start time Periodic automatic switching test cycle

PARAMETER 1 to 4 Check Check

Check

Switch-Over Mode Counter Setting at Manual Switching PSWO (Prolonged Switchover) Alarm Waiting Timer PPF (Prolonged Protection Failure) Alarm Watiting Timer Excerciser Start Timer Excerciser Cycle

Auto > Manual / Manual > Auto Stop / Not Stop 0 to 255 seconds 0 to 255 seconds HH:MM (24 hours basis) HH (24 hours basis)

NOTE Alongwith the line status, be sure to check the Sending End Line and/or Receiving End Line boxes. Otherwise, SWOPROC may malfunction.

- 94 -

ROI-S06269

7.3.5

Automatic Protection Switching for Optical Interface Redundancy

UNIT MDP

MODULE BB SW CTRL

ITEM SYS A SYS B SYS C SYS D SYS E Lock-in Mode Usage Count Detect Time Hold Time

DESCRIPTION SYS A Automatic protection switching method SYS B Automatic protection switching method SYSC Automatic protection switching method SYS D Automatic protection switching method SYS E Automatic protection switching method To set whether Lock-in Modeis to be used (or not) To set the number of times increment after which Lock-in is to be activated. To set the amount of time after which Lockinis to be activated To set the length of time for which Lock-in is to be maintained Setting of switching priority configuration To set whether the function is to be used for the Main Signal when switching

PARAMETER Uni-Directional Non Revertive /Uni-Directional Revertive Uni-Directional Non Revertive /Uni-Directional Revertive Uni-Directional Non Revertive /Uni-Directional Revertive Uni-Directional Non Revertive /Uni-Directional Revertive Uni-Directional Non Revertive /Uni-Directional Revertive Enable / Disable 1 to 255 times 1 to 60 minutes 1 to 48 hours Alarm > Command [LKOP>SF(P)>FSW>SF(W)] Command > Alarm [LKOP>FSW>SF(P)>SF(W)] Enable / Disable

Signal Fail (P) Priority

Signal Degrade Usage

- 95 -

ROI-S06269

7.3.6

SDH Clock Synchronization for Multiplexer Section Termination Mode

UNIT MDP

MODULE CLK

ITEM (No Items in RST mode)

DESCRIPTION

PARAMETER

7.3.7

Alarm Reporting and Exernal Relay Output

UNIT MDP

MODULE CTRL

ITEM Alarm Correlation CTRL External DO Configuration

DESCRIPTION Secondary alarm mask Total alarm assignment for external relay output

PARAMETER Enable / Disable (Assignment in table)

- 96 -

ROI-S06269

7.3.8

Radio Frame Performance Monitor

UNIT MDP

MODULE MODEM

ITEM HOP High BER Alarm (50% Activation) Section Low BER Alarm (50% Activation) Section High BER Alarm (50% Activation) Early Warning

PMON SES Threshold

DESCRIPTION Hop High BER alarm threshold for the incoming signal from DMR direction Section Low BER alarm threshold for the incoming signal from the DMR direction Section High BER alarm threshold for the incoming signal from the DMR direction Early Warning threshold for the incoming signal from the DMR direction (used for Hitless Switch) BER threshold for starting the HOP Severy Errored Second counting

PARAMETER 3E-4/5/6/7/8 3E-6/7/8/9/10

3E-4/5/6/7/8

3E-8/9/10/11/12 30% / 15%

- 97 -

ROI-S06269

7.3.9

STM-1 Frame Performance Monitor

- 98 -

ROI-S06269

UNIT MDP

MODULE OPT INTFC / 150M INTFC

ITEM Error Pulse Selection Signal Degraded(B1) from MUX Signal Degraded(B1) from DMR Excessive BER(B1) from DMR

DESCRIPTION Error pulse selection for the external output STM-1 signal Degradation (B1) alarm threshold for the incoming signal from MUX direction STM-1 signal Degradation (B1) alarm threshold for the incoming signal from DMR direction STM-1 excessive BER (B1) alarm threshold for the incoming signal from DMR direction

PARAMETER B1 Error Pulse/ B1 Block Error Pulse 1E-5/6/7/8/9 1E-5/6/7/8/9 1E-3/4/5 Disable/ Enable(Auto Start/Manual Clear)/ Enable(Manual Start)/ Enable(Manual Restart for Test) -

Automatic Laser Shutdown *1

Automatic laser shutdown mode

Disable Enable(Auto Start/Manual Clear)

Enable(Manual Start) *2

Enable(Manual Restart for Test) *2 Section Trace (J0) Mode (Fm/To MUX) J0 Select (Fm/To MUX) Transmit Pattern (Fm/To MUX) Expected Pattern(Fm/To MUX) Monitor Requirement (Fm/To MUX) Section Trace (J0) Mode (Fm/To DMR) J0 Select (Fm/To DMR) Transmit Pattern (Fm/To DMR) Expected Pattern(Fm/To DMR) Monitor Requirement (Fm/To DMR) PMON SES Threshold

When Automatic Laser Shutdown is not to be used. When Automatic Laser Shutdown is to be used. Must be selected to clear controls after performing Manual Control Optical output between 2sec is selected and Execute is performed; an optical output is stopped between 1min. Operation is repeated in 1min. intervals Optical output between 90sec is selected and Execute is performed; an optical output is stopped between 1min. Then output is resumed for 2sec. Operation is repeated in 1min. intervals. For adjusting the JO pattern for From/To For setting whether JO is to be used (or not) for From/To MUX For setting From/To transmitting pattern For setting expected From/To MUX pattern Monitor for From/To MUX receiving pattern For setting JO pattern for From/To DMR For setting whether JO is to be used (or not) for From/To DMR Enable / Disable For setting transmitting pattern for From/To DMR For setting expected pattern for From/To DMR Monitor for From/To DMR receiving pattern BER threshold for starting the STM-1 Severely Errored Second (B1) counting

Get J0 / Set J0 Enable / Disable ASCII 15Characters ASCII 15Characters Get J0 / Set J0 Enable / Disable ASCII 15Characters ASCII 15Characters 30% / 15%

NOTES) *1 "Automatic Laser Shutdown" is NOT applicable to 150M INTFC. *2 MAINT control is necessary (for CTRL)

- 99 -

ROI-S06269

MAINTENANCE CONTROL
Following items are used to adjust and simulate in installation and maintenance time.

8.1

MENU
UNIT TRP MDP MODULE TRP SD/2SD MODEM OPT INTFC / 150M INTFC OH/WS INTFC CLK SWO PROC BB SW CTRL ITEM Fixed Transmit Level Setting for occasional operation without ATPC MAIN-SD Delay Adjustment for IF signal combiner XPIC Reset PROT-REG Delay Adjustment for Hitless Switching Wayside Switchover Manual Control (No Items in RST mode) Radio Protection Switchover Manual Control Automatic Protection Switchover Manual Control

CAUTION: When executing TEST ITEMs, Loss Of Signal will occur. Moreover, when SYS1/SYS2 are both remote controlled, a remote deletion is not possible!

8.2

SETTING METHOD

8.2.1

METHOD-1: MODULE basis operation

1. Select "Configuration" - "Maintenance Control" - "No.X" - "TRP-MODULE" or "MDP[XXXX]-MODULE" from NE Specific Menu Bar; then following "MODULE Detail" screen appears. 2. Select the MODULE Tab, and click the Item button; then following setting screen appears. 3. Select the parameter, or input the value, and click "Execute" button, then click "Close" button to finish. 4. Repeat for applicable items.

8.2.2

METHOD-2: SYS basis operation

1. Select "Configuration" - "Maintenance Control" - "No.X" - "TRP-SYS" or "MDP[XX-XX]SYS" 2. Select the SYS Tab, and click the Item button, then following setting screen appears.(same screen as above) 3. Select the parameter, or input the value, and click the "Execute" button; then click "Close" button to finish. 4. Repeat for all applicable items.

- 100 -

ROI-S06269

Example of moving module to TRP menu

- 101 -

ROI-S06269

Example of moving module to MDP menu

- 102 -

ROI-S06269

8.3

DETAILS

8.3.1

Fixed Transmit Level Setting for occasional operation without ATPC

UNIT TRP

MODULE TRP

ITEM Manual Transmit Level Control Manual Transmit Level Control Power

DESCRIPTION Manual control usage TX Level for manual control

PARAMETER On / Off Nominal Level -20 to 0 dB

- 103 -

ROI-S06269

8.3.2

MAIN-SD Delay Adjustment for IF signal combiner

UNIT TRP

MODULE SD/ 2SD

ITEM Adjust Adjust Operation value

DESCRIPTION Delay Equalizer Insert Side Selection SD:SD side, Main:MAIN side, Disable:Not used Delay Adjust Value Selection Delay Adjust Mode Selection Adjust:Occasional adjust, Save:Eternal Adjust, Revert: to default value

PARAMETER SD / Main / Disable 1 to 127 nano second

Adjust Operation mode

Adjust / Save / Revert

- 104 -

ROI-S06269

8.3.2.1

Adjust

Before configuring the DADE Adjust function, only the [Adjust] button is enabled (clickable) in the Detail Window; the [Adjust Operation Value] and the [Adjust Operation] buttons are disabled (not clickable).

In order to perform the DADE adjust function, first open the DADE Adjust window according to the following procedure, and select the Adjust mode. Then, actual DADE adjust configuration can be carried out.

Configuration:

1. 2. 3. 4.

Click the [Adjust] Button of Maintenance Control Window. Select SD, Main, and Disable by the list box in the Adjust column. Click [Execute] button. After completion, the [Close] button will be clicked and a window will be closed.

- 105 -

ROI-S06269

8.3.2.2

Adjust Operation

If selection in adjustment mode is performed on the DADE Adjust window, selection of the [Adjust Operation Value] button and the [Adjust Operation] button will be attained in Detail Window (selection of the [Adjust] button becomes impossible).

The following is the DADE Adjust procedure.

Configuration:

1. 2. 3.

Click the [Adjust Operation Value] button of a Maintenance Control window, or [Adjust Operation]. Input a setting value into the text box of the Adjust Operation column in 1-127. Select Adjust, Save, and Revert with a radio button in the Adjust Operation column.

- 106 -

ROI-S06269

4.

[Click the [Execute] button. NOTE When text inputted in a text box exceeds 127 characters, a warning message is displayed when the [Execute] button is clicked, and the entered text is invalid.

5.

After completion, the [Close] button will be clicked and a window will be closed.

If selection in adjustment mode is performed on the DADE Adjust window and Detail DADE adjustment will be finished, in Detail Window, it will be in the state which can choose only the [Adjust] button again.

- 107 -

ROI-S06269

8.3.3

Cross Polarization Interference Canceller Reset

UNIT MDP

MODULE MODEM

ITEM XPIC Reset

DESCRIPTION ATPC action reset

PARAMETER Reset/Normal

- 108 -

ROI-S06269

8.3.4

PROT-REG Delay Adjustment for Hitless Switching

UNIT MDP

MODULE OPT INTFC / 150M INTFC

ITEM Delay Adjust PROT FASYNC REG FASYNC Adjust Time Out PROT REG

DESCRIPTION Delay adjust between PROT and REG CH STM-1 Frame synchronization monitor STM-1 Frame synchronization monitor Adjust time out monitor Adjusted bit number monitor Adjusted bit number monitor Execute

PARAMETER

(To be displayed after execute) (To be displayed after execute) (To be displayed after execute) (To be displayed after execute) (To be displayed after execute)

Note) Please do not operate the Delay Adjustfunction until 4.2.1.6 has been carried out!

TX Test Operation

- 109 -

ROI-S06269

8.3.5

Wayside Switchover Manual Control

UNIT MDP

MODULE OH/WS INTFC

ITEM

DESCRIPTION Forced:Not switched in any condition. Manual:Not switched except alarm Auto :Switched by alarm

Switching Control

PARAMETER Forced-Prot / Forced-Reg / Manual-Prot / Manual-Reg / Auto

- 110 -

ROI-S06269

8.3.6

SDH Clock Synchronization for Multiplexer Section Termination Mode

UNIT MDP

MODULE CLK

ITEM (No Items in RST mode)

DESCRIPTION -

PARAMETER

8.3.7

Radio Protection Switchover Manual Control

UNIT MDP

MODULE SWO PROC

ITEM

DESCRIPTION Forced: Not switched in any condition. Manual: Not switched except alarm Auto : Switched by alarm

Switching Control (TX Side)

Switching Control (RX Side)

Forced: Not switched in any condition. Manual: Not switched except alarm Auto : Switched by alarm LockOut: Lock of Protection Forced : Not switched in any condition Manual : Not switched except alarm Control to inhibit automatic switchover of the line. Some alarm events have occurred and then cleared all of them. Controls the counter function operation.

PARAMETER Forced Switch-Work / Forced Switch-Prot / Manual Switch-Work / Manual Switch-Prot / Auto Forced Switch-Work / Forced Switch-Prot / Manual Switch-Work / Manual Switch-Prot / Auto ON/OFF ON/OFF ON/OFF Reset Stop/Restart

Switchover Operation Disable Operation RCVY Operation Counter Operation

- 111 -

ROI-S06269

8.3.8

Automatic Protection Switchover Manual Control

UNIT MDP

MODULE BB SW CTRL

ITEM

DESCRIPTION Lock Of Protection: Lock of Protection Forced :Not switched in any condition. Manual :Not switched except alarm Auto :Switched by alarm

BB SW Control Mode (SYS A/B/C/D/E)

PARAMETER Lock Of Protection / Forced Switch-Work / Forced Switch-Prot / Manual Switch-Work / Manual Switch-Prot / Auto

Lock-in Status (SYS A/B/C/D/E)

To clear Lock-in Status

Clear

SYS A-E and SYS1-10supportability NE mounting position and display ability on PNMTj
CTRL No SYS No SYS A SYS B SYS C SYS D SYS E CTRL 1,3,5,7 SYS 1 SYS 2 SYS 3 SYS 4 SYS 5 CTRL 2,4,6,8 SYS 6 SYS 7 SYS 8 SYS 9 SYS 10

- 112 -

ROI-S06269

MAINTENANCE TEST
Following items are used to test in installation and maintenance time.

9.1

MENU
UNIT TRP MODULE TRP ITEM Receive AGC stop Carrier Sweep Function TX Level Muting Frequency Setting Modulation Stoppage for output the carrier signal IF and Baseband Loopback Demodulation Carrier Phase Inverting Antenna Alignment mode Baseband Loopback STM-1 Fixed Pattern Output mode WS Fixed Pattern Output mode Switchover Test mode Switchover Reset PURPOSE Noise Figure Measurement MAIN-SD Delay Adjustment TX Level Muting Test Frequency Setting Test TX Frequency Measurement IF or Baseband Loopback Test Carrier Phase Inverting Test Antenna Alignment Test Baseband Loopback Test STM-1 Pulse Mask Measurement WS Pulse Mask Measurement Switchover Test Switchover Test

MDP

MODEM

OPT INTFC/ 150M INTFC OH/WS INTFC SWO PROC BB SW CTRL

CAUTION: When executing TEST ITEMs, Loss Of Signal will occur. Moreover, when SYS1/SYS2are both remote controlled, a remote deletion is not possible!

9.2
9.2.1

SETTING METHOD
METHOD-1: MODULE basis operation

1. Select "Configuration" - "Maintenance Test" - "No.X" - "TRP-MODULE" or "MDP[XX-XX]MODULE" from NE Specific Menu Bar, then following "MODULE Detail" configuration window appears. 2. Select the MODULE Tab, and click the Item button, then the following setting configuration window appears. 3. Select the parameter, or input the value, and click "Execute" button, then click "Close" button to finish. 4. Repeat for applicable items.

9.2.2

METHOD-2: SYS basis operation

1. Select "Configuration" - "Maintenance Test" - "No.X" - "TRP-SYS" or "MDP[XX-XX]-SYS" 2. Select the SYS Tab, and click the Item button, then following setting configuration window appears.(same screen as above) 3. Select the parameter, or input the value, and click "Execute" button, then click "Close" button to finish. 4. Repeat for applicable items.

- 113 -

ROI-S06269

Example case for moving to TRP menu

- 114 -

ROI-S06269

Example case for moving to MDP menu

- 115 -

ROI-S06269

9.3
9.3.1

DETAILS
TRP Test Function

UNIT TRP

MODULE TRP

ITEM Receive Level AGC Function Carrier Sweep Function Transmitter Power Mute Frequency Setting Revert TX Frequency RX Frequency

DESCRIPTION AGC stoppage for Noise Figure measurement Carrier sweeping for MAIN-SD Delay Adjustment TX Level muting Last memorized setting reverting TX frequency setting RX frequency setting

PARAMETER Test (Noise Figure) / Normal (AGC On) Sweep for DADE V / Disable Mute / Auto (To be checked and executed) (To be input as MHz basis) (To be input as MHz basis)

- 116 -

ROI-S06269

9.3.2

MODEM Test Function

UNIT MDP

MODULE MODEM

ITEM MOD Carrier Output Loopback Test Antenna Alignment Mode *1

DESCRIPTION Modulation stopping for output carrier signal IF and Baseband Loopback

the

PARAMETER Carrier Output / Normal BB Loopback (Fm/To DMR) / IF Loopback (Fm/To MUX)/ Normal Enable / Disable

IF Input Level Monitoring Output High Speed Renewal mode

NOTE *1:Mode switchover may take a while.

- 117 -

ROI-S06269

9.3.3

Baseband Loopback Test and STM-1 Pulse Mask Measurement

UNIT MDP

MODULE OPT INTFC / 150M INTFC

ITEM Loopback Test Base Band Output Control

DESCRIPTION Loopback mode Fixed pattern output for STM-1 Pulse Mask measurement

PARAMETER BB Loopback Fm/To MUX / BB Loopback Fm/To DMR / Normal all"1" / all"0" / Normal

NOTES) "Base Band Output Control" is NOT applicable to OPT INTFC.

- 118 -

ROI-S06269

9.3.4

WS Pulse Mask Measurement

UNIT MDP

MODULE OH/WS INTFC

ITEM Wayside Output Control

DESCRIPTION Fixed pattern output for T1(1.5MB) Pulse Mask measurement

PARAMETER Isolated Pulse Output / Normal

- 119 -

ROI-S06269

9.3.5

Radio Protection Switchover Test

UNIT MDP

MODULE SWO PROC

ITEM TX Test Exercise

DESCRIPTION Remote station Tx SW control. Manual Exercise Control

PARAMETER ON/OFF Manual Exercise

9.3.6

Automatic Protection Switchover Reset

UNIT MDP

MODULE BB SW CTRL

ITEM BB SW CTRL Reset

DESCRIPTION Module action reset Reset

PARAMETER

- 120 -

ROI-S06269

10 MAINTENANCE INFORMATION
In a Maintenance Information screen, it is a control item while carrying out a CTRL-related maintenance configuration. Item is displayed by list. Unless all configuration currently displayed here is canceled, Maintenance of CTRL cannot be set as OFF. It displays by the following methods.

[Configuration]-[Maintenance Information] is selected in NE-Specific Menu Bar.

- 121 -

ROI-S06269

NOTE When nothing displays on screen When there is no Item, the following dialogs are displayed, and if [O.K.] is clicked, screen will close.

NOTE Item under control If it is going to set Maintenance of CTRL as OFF when Item exists, the following warning dialogs are displayed and it cannot set to OFF. the contents as which the contents displayed here are displayed by Maintenance Information-- the same .

- 122 -

ROI-S06269

11 LINK PERFORMANCE MONITOR


Performance item defined by G.ITU-T 826 standard for every module by Link Performance Monitor Item is displayed. Display item changes with selected modules.

The items applicable to 5000SAre displayed as follows: (1) OPT INTFC/150M INTFC(WORK)
15min. resistor range 0-900 02160000 0-900 0-900 0-900 0-900 0-900 02160000 0-900 0-900 0-900 0-900 1day resistor range 0-86400 0207360000 0-86400 0-86400 0-86400 0-86400 0-86400 0207360000 0-86400 0-86400 0-86400 0-86400 15min. resistor width 10 22 10 10 10 10 10 22 10 10 10 10 1day resistor width 17 28 17 17 17 17 17 28 17 17 17 17

NO 1 2 3 4 5 14 23 24 25 26 27 36

Title OFS(R) RS NBBE(R B1) RS NES(R B1) RS NSES(R B1) RS NSEP(R B1) RS NUAS(R B1) OFS(S) RS NBBE(S B1) RS NES(S B1) RS NSES(S B1) RS NSEP(S B1) RS NUAS(S B1)

Function RfacingOut of Frame Second RfacingB1 Near-end Near-end Background Block Error RfacingB1 Near-end Errored Second RfacingB1 Near-end Severely Errored Second RfacingB1 Near-end Severely Errored Period RfacingRST(B1) Near-end Unavailable Second SfacingOut of Frame Second SfacingB1 Near-end Background Block Error SfacingB1 Near-end Errored Second SfacingB1 Near-end Severely Errored Second SfacingB1 Near-end Severely Errored Period SfacingRST(B1) Near-end Unavailable Second

(2) OPT INTFC(PROT)


15min. resistor range 0-900 02160000 0-900 0-900 0-900 0-900 0-900 02160000 0-900 0-900 0-900 0-900 1day resistor range 0-86400 0207360000 0-86400 0-86400 0-86400 0-86400 0-86400 0207360000 0-86400 0-86400 0-86400 0-86400 15min. resistor width 10 22 10 10 10 10 10 22 10 10 10 10 1day resistor width 17 28 17 17 17 17 17 28 17 17 17 17

NO 74 75 76 77 78 87 96 97 98 99 100 109

Title OFS(R) RS NBBE(R B1) RS NES(R B1) RS NSES(R B1) RS NSEP(R B1) RS NUAS(R B1) OFS(S) RS NBBE(S B1) RS NES(S B1) RS NSES(S B1) RS NSEP(S B1) RS NUAS(S B1)

Function RfacingOut of Frame Second RfacingB1 Near-end Background Block Error Rfacing B1 Near-end Errored Second RfacingB1 Near-end Severely Errored Second RfacingB1 Near-end Severely Errored Period RfacingRST(B1) Near-end Unavailable Second SfacingOut of Frame Second SfacingB1 Near-end Background Block Error SfacingB1 Near-end Errored Second SfacingB1 Near-end Severely Errored Second SfacingB1 Near-end Severely Errored Period SfacingRST(B1) Near-end Unavailable Second

- 123 -

ROI-S06269

(4) MODEM
15min. resistor range 0-900 0-900 02380500 02252700 0-900 0-900 1day resistor range 0-86400 0-86400 0228528000 0216259200 0-86400 0-86400 15min. resistor width 10 10 22 22 10 10 1day resistor width 17 17 28 28 17 17

NO 61 68 69 70 71 72 OFS BBE ES SES SEP UAS

Title Out of Frame Second

Function

Background Block Error Errored Second Severely Errored Second Severely Errored Period Unavailable Second

(5) TRP/SD/2SD
15min. resistor range 1-900 1-900 1-900 1-900 Receive Level Average 1day resistor range 1-86400 1-86400 1-86400 1-86400 15min. resistor width 10 10 10 10 1day resistor width 17 17 17 17 -

NO 124 125 126 127 128 129 130

Title RX Level TCS MAIN Level TCS SD Level TCS 2SD Level TCS RX Level MIN RX Level MAX RX Level AVRG

Function RX Level Threshold Crossed Seconds Count Main RX Level Threshold Crossed Seconds Count SD RX Level Threshold Crossed Seconds Count SD RX Level Threshold Crossed Seconds Count Receive Level Minimum Receive Level Maximum

(6) BB SW CTRL
15min. resistor range 1-900 1-900 1day resistor range 1-86400 1-86400 15min. resistor width 10 10 1day resistor width 17 17

NO 131 132 PSC PSD

Title

Function Protection Switching Count Protection Switching Duration

(7) SWO PROC


15min. resistor range 0-4095 0-900 0-4095 0-900 0-4095 0-900 0-4095 0-900 0-4095 0-900 1day resistor range 0-4095 0-1440 0-4095 0-1440 0-4095 0-1440 0-4095 0-1440 0-4095 0-1440 15min. resistor width 12 10 12 10 12 10 12 10 12 10 1day resistor width 12 11 12 11 12 11 12 11 12 11

NO 1 2 3 4 5 6 7 8 9 10 Switching Count Switching Duration Switching Fail Count Switching Fail Duration Switching Count Switching Duration Switching Fail Count Switching Fail Duration Eary Warning Count Eary Warning Duration

Title

- 124 -

ROI-S06269

11 12 13 14

BER ALM Count BER ALM Duration FSYNC ALM Count FSYNC ALM Duration

0-4095 0-900 0-4095 0-900

0-4095 0-1440 0-4095 0-1440

12 10 12 10

12 11 12 11

11.1 Viewing Summary Link Performance Monitor


It displays by the following methods.

1. If [Performance Monitor]-[Link Perfomrance Monitor]-[LPM] is selected in NE-Specific Menu Bar, a Link Performance Monitor Select screen will be displayed.

2. if Clear is boiled and a check is put in, the check of all the modules about selected SYS will separate. If a check is put into Select, the check of all the modules about selected SYS will enter.

if Clear is boiled and a check is put in, the check of all the modules about selected SYS will separate. If a check is put into Select, the check of all the modules about selected SYS will enter. 3. Item which wishes to display on Link Performance Monitor Select screen If the [O.K.] button is clicked after putting a check into Item, a Link Performance Monitor [Current] screen will be displayed.

- 125 -

ROI-S06269

Performance item displayed The meaning of the sign added to the background colour of Item and a numerical head is shown below. : Item which TCN alarm has generated : Item acquired in Maintenance * + : Invalid data : Item which overflowed the PMON register

11.1.1

Link Performance Monitor (1day / 15 min. Data) window

To view the 1day Data: The Link Performance Monitor [Daily Data] screen is displayed by clicking the button portion of a SYS name on a Link Performance Monitor [Current] screen.

Link Performance Monitor (1 day Data) window To view the 15-min. Data: Click button of the target date in Link Performance Monitor [Daily Data] window to display the detailed 15-minute performance data.

- 126 -

ROI-S06269

Link Performance Monitor (15-min. Data) window The data can be saved in text format by clicking on the save icon. Or it can be refreshed by clicking on the reload (refresh) icon.

11.2 Threshold Setting


It displays by the following methods.

1. If [Performance Monitor]-[Link Perfomrance Monitor]-[Threshold] is selected in NESpecific Menu Bar, a Link Performance Monitor Select screen will be displayed.

2. If a SYS pull down is clicked on a Link Performance Monitor Select screen, the sub menu of Clear/Select will be displayed as follows.

If a check is put in Clear, the check of all the modules about selected SYS will separate If a check is put into Select, the check of all the modules about selected SYS will enter. processed accordingly.

- 127 -

ROI-S06269

3. Item intended to display on Link Performance Monitor Select screen If the [O.K.] button is clicked after putting a check into Item, a Link Performance Monitor [Current] screen will be displayed.

4. A TCN setting screen is displayed by clicking the button of a SYS name.

5. When a TCN value is inputted in a TCN configuring screen and the [O.K.] button is clicked, the TCN value is saved to the NE

6. When the All Select box is checked, and the [OK] button is clicked, the same TCN value will be set for all existing SYS.

NOTE When the All Select box is checked, there are certain limitations on the operations that can be performed (see below for details). ALL SELECT should be used when all actually mounted SYS modules are identical.

- 128 -

ROI-S06269

1)

When selecting all the SYS mounted modules Select SYS1 MODEM

When modems SYS2 to 5 are io be set for the same TCN value as the SYS1 MODEM.

Since SYS1 has no INTFC board, the TCN values from SYS2 to 5will be the default setting

2)

When a module is selected that is mounted only in designated SYS Select SYS2 OPT INTFC
Only SYS2 and SYS3 have an OPT INTFC board, it cannot be set by ALL SELECT for the others. Only SYS2 and SYS3 have an OPT INTFC board, ALL SELECT setting is only possible for them.

3)

Close window by clicking the [Close] button.

- 129 -

ROI-S06269

12 METERING
A metering function is a function for monitoring the modular measurement data. By specifying arbitrary panel/values from PNMT, it is possible to monitor the values in real time. Item used as the candidate for metering data monitoring essentially are the following items of a MODEM module. TRANSMIT LEVEL RECEIVE LEVEL MAIN RECEIVE LEVEL SD RECEIVE LEVEL BER At 10 second intervals, data for the stipulated item is retrieved, numerically converted and displayed on the screen.

The following table provides a brief description of the displayed items:


Item/Feature Transmit Level Receive Level Main Receive Level SD Receive Level output BER Description Level of Transmitter Output Power at Antenna port Level of Received Signal (where an SD signal is present, it is the level of the combined signal) Level of Received Main Signal Level of Received SD Signal

Hop Bit Error Rate

- 130 -

ROI-S06269

12.1 Viewing Summary Metering Window


To view Summary Metering Window: 1. Select [Performance Monitor]-[Metering] in NE-Specific Menu Bar.

2.

Select the SYS you wish to display and click [OK].

Summary Metering Select window 3. Acquire data automatically every 10 seconds and display the newest state.

Summary Metering window The exact metered value is displayed on a green bar graph in the status column. "***" is displayed for values outside the measurement range of the respective item. When no metered value can be acquired from the NE, the Status column remains blank; but, is shaded in grey.

- 131 -

ROI-S06269

13 EVENT LOG
The Event Log window displays the date/time when the event data was received, item, and status.

13.1 Event Log monitor


Click [NE Stored Log] in the NE-specific menu bar. Wait until the PNMT finishes the uploading of the data. The NE Stored Log View will be displayed. The event log is presented in a table form showing the date of the event, the item that triggered the event and the status change. Sorting is possible for every column in the Event Log window. The date shown in the Event Log window will be in the format of the OS. The data can be refreshed by clicking on the upload (Reload) icon.

- 132 -

ROI-S06269

14 ALARM LIST
The alarm under present generating is expressed as an Alarm List screen in list form.

14.1 Alarm List Window


1. The alarm under present generating is expressed as an Alarm List screen in list form.

2. The alarm generated / restored is automatically reflected in the contents of AlarmList. 3. It is each item by clicking the column name area of Location, Item, and Severity. Sorting by Item is possible. 4. Exit this screen by choosing [List]-[Close] from a menu.

- 133 -

ROI-S06269

15 INVENTORY
The relevant inventory information for the equipment can be viewed using this function.

15.1 Inventory Monitor


To display the equipment version: [Configuration]-[Inventory]-[No.xx] is selected in NE-Specific Menu Bar Alternatively, click the INVENTORY icon in the Others column

- 134 -

ROI-S06269

16 Cautionary Notes
16.1 Error message when multiple controlling operations are underway
When another control operation is initiated in PNMT before a previous one is completed, the following error message will be displayed on both control screens: "Other request is being executed." Other request is being executed. " (The earlier one will be properly completed nonetheless).

(1) controlled

remote login

(2) separately controlled (1)controlled remote login

- 135 -

ROI-S06269

(4)error type is displayed


(3) Although controlling is successful, an error is displayed indicating that remote processing did not work

remote login

- 136 -

ROI-S06269

Appendix A:

Equipment Network Settings

In Equipment Network Setting, the setting parameters for each NE are different. They depend on the LMS Type selection (Equipment Type, LMS Type, and Branch NE Type).
Equipment Type LMS Type (General) LMS Branch NE Type Type Category Input Item Equipment Type General LMS Type Branch NE Type Root NE Not selectable DIR-A/EM2 PNMS(EM1) Routing IP Address Subnet Mask IP Address Subnet Mask Default Gateway Static Routing Table Equipment Type General LMS Type Branch NE Type Root NE (Bridge) Not selectable DIR-A/EM2/EM1 PNMS() Routing IP Address Subnet Mask IP Address Subnet Mask Default Gateway Static Routing Table Equipment Type General Terminal No Branch (Not used) LMS Type Branch NE Type DIR-A/EM2/EM1 Routing IP Address Subnet Mask Default Gateway Static Routing Table Equipment Type General LMS Type Branch NE Type 2 Branches Branch NE DIR-A EM1/EM2 Routing IP Address Subnet Mask IP Address Subnet Mask Default Gateway Static Routing Table Equipment Type General LMS Type Branch NE Type 3 Branches DIR-A EM1 EM2 IP Address Subnet Mask IP Address Subnet Mask IP Address Subnet Mask

- 137 -

ROI-S06269

Equipment Type

LMS Type (General) LMS Branch NE Type Type Branch NE 3 Branches

Category

Input Item Default Gateway Static Routing Table Equipment Type LMS Type Branch NE Type IP Address Subnet Mask Default Gateway Static Routing Table Equipment Type LMS Type Branch NE Type IP Address Subnet Mask IP Address Subnet Mask Default Gateway Static Routing Table Equipment Type LMS Type Branch NE Type IP Address Subnet Mask IP Address Subnet Mask Default Gateway Static Routing Table Equipment Type LMS Type Branch NE Type IP Address Subnet Mask Default Gateway Static Routing Table Equipment Type LMS Type Branch NE Type IP Address Subnet Mask IP Address Subnet Mask Default Gateway Static Routing Table

Routing

General Terminal Normal NE Not selectable Radio/EM1/EM2 Routing

General

Root NE

Not selectable

DIR-A/DIR-B/EM2 PNMS(EM1) Routing

General

Root NE (Bridge)

Not selectable

DIR-A/EM2/EM1 PNMS()

2xTerminal/Repeater

Routing

General No Branch (Not used) DIR-A /DIRB/EM2/EM1 Routing Branch NE

General

2 Branches

DIR-A DIR-B/EM1/EM2 Routing

- 138 -

ROI-S06269

Equipment Type

LMS Type (General) LMS Branch NE Type Type

Category

Input Item Equipment Type

General

LMS Type Branch NE Type IP Address Subnet Mask IP Address Subnet Mask IP Address Subnet Mask Default Gateway Static Routing Table Equipment Type LMS Type Branch NE Type IP Address Subnet Mask IP Address Subnet Mask IP Address Subnet Mask IP Address Subnet Mask Default Gateway Static Routing Table Equipment Type LMS Type Branch NE Type IP Address Subnet Mask Default Gateway Static Routing Table

DIR-A 3 Branches DIR-B EM2/EM1 Routing Branch NE

General

2xTerminal/Repeater 4 Branches

DIR-A DIR-B EM2 EM1 Routing

General Normal NE Not selectable

Radio/EM1/EM2 Routing

Note: Here EM1 / EM2 indicate the IDU front interface NMS/ NE ports respectively

- 139 -

ROI-S06269

In Category General and select there Equipment Type and LMS Type (LMS Type and Branch NE Type)

Port Category Category

The NE will appear as follows according to configuration. Root NE The nearest NE to PNMS configure as Root NE Root NE (Bridge) The nearest NE to PNMS configure as Root NE(No subnet diverges) Branch NE (No Branch) Not used Branch NE (2 Branch) Subnet diverges in two ways Branch NE (3 Branch) Subnet diverges in three ways Normal NE The rest of all NE (except above mentioned) is Normal NE .

- 140 -

ROI-S06269

1.

The Port Category item changes according to LMS Type (LMS Type and Banch NE Type).

Port Category LMS Type = Root NE

Port Category LMS Type = Root NE (Bridge)

LMS Type = Branch NE or Branch NE Type = 2 Branches

LMS Type = Branch NE or Branch NE Type = 3 Branches

LMS Type = Branch NE or Branch NE Type = 4 Branches

- 141 -

ROI-S06269

LMS Type = Normal NE 2. Set and select Port category and Routing. The right hand screen will change according to the selected item in Category.

Primary IP Address PNMS identify a NE with using the IP address in NE. The check can be applied only to 1port category of several Port categories that exists in LMS Type when Branch NE is selected. IP Address & Subnet Mask The following items are set to each Port

PNMS(E1)

Radio or EM1 or EM2 or EM1/EM2

Radio/EM2

Radio/EM1/EM2 3. 4-1 Select and set Routing. If there is no subnet in the network, the Static Routing table will not show any entries.

- 142 -

ROI-S06269

4-2

In case of several subnet in the Network click [add] to entry the required value in Static Routing Table

Click [OK] button to activate the address setting.

[Modify] is clicked to correct the registered value in Static Routing table. [Remove] is clicked to delete the registered value in Static Routing table.

- 143 -

ROI-S06269

4.

Click [Execute] button to activate the Equipment Networking setting. NOTE: When executing Equipment Network Setting communication will be lost when the Control module reinitialises to the new system configuration. This WILL NOT affect the wireless link. During this time PNMT connection to the NE will be lost but will automatically be reconnected after the Control module resets.

- 144 -

ROI-S06269

< Sample Network Configuration > 1. The Network Configuration when subnet is connected.

192.168.0.10 255.255.255.0

172.18.0.1 255.255.255.192

PNMS

No.01

No.02

No.03

No.04

Router

Root NE
192.168.0.1 255.255.255.0

Normal NE
172.18.0.2 255.255.255.192

Normal NE
172.18.0.3 255.255.255.192

Normal NE
172.18.0.4 255.255.255.192

PNMT

NE

General (Category) Equipment Branch NE LMS Type Type Type

Category

Item Name
IP Address Subnet Mask

Input data 172.18.0.1 255.255.255.192 192.168.0.10 255.255.255.0 192.168.0.1 172.18.0.2 255.255.255.192 192.168.0.1 172.18.0.3 255.255.255.192 172.18.0.1 172.18.0.4 255.255.255.192 172.18.0.1 -

Radio/EM2 Not selectable

No.01

Terminal

Root NE

PNMS(EM1)

IP Address Subnet Mask

Routing

Default Gateway Static Routing Table

Radio/EM1/EM2 No.02 Terminal Normal NE Not selectable Routing

IP Address Subnet Mask Default Gateway Static Routing Table

Radio/EM1/EM2 No.03 Terminal Normal NE Not selectable Routing

IP Address Subnet Mask Default Gateway Static Routing Table

Radio/EM1/EM2 No.04 Terminal Normal NE Not selectable Routing

IP Address Subnet Mask Default Gateway Static Routing Table

- 145 -

ROI-S06269

2.

The Network configuration in case of several subnets (Branch NE Type = 2 Branches)


192.168.0.10 255.255.255.0 172.18.0.1 255.255.255.192 172.18.0.3 255.255.255.192

PNMS

No.01

No.02

No.03

No.04

Router

Root NE
192.168.0.1 255.255.255.0

Normal NE
172.18.0.2 255.255.255.192

Branch NE
172.18.0.65 255.255.25-5.192

Normal NE
172.18.0.66 255.255.255.192

PNMT

NE

General (Category) Equipment LMS Branch Type Type NE Type

Category

Item Name
IP Address Subnet Mask

Input data 172.18.0.1 255.255.255.192 192.168.0.10 255.255.255.0 192.168.0.1 IP Address Subnet Mask Default Gateway 172.18.0.2 255.255.255.192 192.168.0.1 172.18.0.65 255.255.255.192 172.18.0.3 255.255.255.192 172.18.0.1 172.18.0.66 255.255.255.192 172.18.0.1 172.18.0.64 255.255.255.192 172.18.0.3

Radio/EM2

No.01

Terminal

Root NE

Not selectable

PNMS(EM1)

IP Address Subnet Mask Default Gateway

Routing Static Routing Table IP Address Subnet Mask Routing Default Gateway Static Routing Table Radio Branch NE IP Address Subnet Mask No.03 Terminal 2 Branches EM1/EM2 IP Address Subnet Mask Default Gateway Static Routing Table Radio/EM1/EM2 No.04 Terminal Normal NE Not selectable Routing IP Address Subnet Mask Default Gateway Static Routing Table

Radio/EM1/EM2 No.02 Terminal Normal NE Not selectable

Routing

- 146 -

ROI-S06269

3.

The Network configuration in case of several subnets (Branch NE Type = 3 Branches)

192.168.0.10 255.255.255.0

172.18.0.1 255.255.255.192

EM1

172.18.0.3 255.255.255.192

172.18.0.65 255.255.25-5.192

PNMS

No.01

No.02

No.03

No.04

Router

Root NE
192.168.0.1 255.255.255.0

Normal NE
172.18.0.2 255.255.255.192

Branch NE EM2
172.18.0.129 255.255.255.192

Normal NE
172.18.0.66 255.255.255.192

No.05

No.06

PNMT Normal NE
172.18.0.130 255.255.255.192

Normal NE
172.18.0.131 255.255.255.192

NE

General (Category) Equipment LMS Branch Type Type NE Type

Category

Item Name
IP Address Subnet Mask

Input data 172.18.0.1 255.255.255.192 192.168.0.10 255.255.255.0 192.168.0.1 IP Address Subnet Mask Default Gateway IP Address Subnet Mask Default Gateway 172.18.0.2 255.255.255.192 192.168.0.1 172.18.0.65 255.255.255.192 172.18.0.3 255.255.255.192 172.18.0.129 255.255.255.192 172.18.0.1 172.18.0.66 255.255.255.192 172.18.0.1 172.18.0.64 255.255.255.192 172.18.0.3 172.18.0.128 255.255.255.192 172.18.0.3

Radio/EM2

PNMS(EM1) No.01 Terminal Root NE Not selectable Routing

IP Address Subnet Mask Default Gateway

Static Routing Table

Radio/EM1/EM2 No.02 Terminal Normal NE Not selectable Routing

IP Address Subnet Mask Default Gateway Static Routing Table

Radio

IP Address Subnet Mask

EM1 No.03 Terminal Branch NE 3 Branches EM2

IP Address Subnet Mask IP Address Subnet Mask Default Gateway Static Routing Table

Routing

Radio/EM1/EM2 No.04 Terminal Normal NE Not selectable Routing

IP Address Subnet Mask Default Gateway Static Routing Table

- 147 -

ROI-S06269

NE

General (Category) Equipment LMS Branch Type Type NE Type


Normal NE Not selectable

Category

Item Name
IP Address Subnet Mask

Input data 172.18.0.130 255.255.255.192 172.18.0.1 172.18.0.131 255.255.255.192 172.18.0.1 -

Radio/EM1/EM2 No.05 Terminal

Routing

Default Gateway Static Routing Table IP Address Subnet Mask

Radio/EM1/EM2 No.06 Terminal Normal NE Not selectable Routing

Default Gateway Static Routing Table

- 148 -