Vous êtes sur la page 1sur 4

CH210A - 01 DRUM

21,000 LB First Layer Line Pull


DIMENSIONAL INFORMATION
SPLIT FLANGE

C
4.67

19.92

29.75

14.88

HOIST

HOIST

9.96
26.5

15.0

1.31

4.81

1.13
27.5

0.16
1.12
2.38

HOIST PORT
SAE 1.50 CODE 61
SPLIT FLANGE

14.25
LOWERING PORT
SAE -16 ORB
(1 5/16-12 THD)

1.03
3.12

4X 1.06 THRU
MOUNTING
HOLES
MOUNTING
HOLES
4 X 1.06 DIAM.
THRU

13.21

3.38
26.37

MOTOR
090
MOTOR
110
110
120
120
090
128/064
128/064

A
A5.38
B
5.63
7.75
5.63
5.75
7.88
5.75
5.38 7.50
8.56
8.56 10.56

B
C 7.50
38.697.75
38.827.88
38.44
10.56
43.68

C
38.44
38.69
38.82
43.68

3.75
5.29

5.81

10.5
21.0

LOWER PORT
SAE 1.50 CODE 61
SPLIT FLANGE

5.50

2 SPEED
SHIFT PORT

4.22

2-SPEED MOTOR

HOIST

MOTOR OPTIONS

Increased line pull ratings to better utilize higher strength wire ropes
Gearing is designed for improved service life at higher input RPM and higher
input torque
New brake design increases allowable input RPM, overrunning clutch capacity
and oil flow to the brake
SAE C and D motor mounts for improved hydraulic motor compatibility
Optional electronic rotation sensor
Same mounting hole locations and envelope size as the CH185A
Improved serviceability
COPYRIGHT 2001
PACCAR WINCH DIVISION

HOIST PORT
SAE -16 ORB

PRINTED IN U.S.A.

090 9.02 cu in.


110 11.03 cu in.
120 12.03 cu in.
128/064 12.76/6.38 cu in. (2 speed)

Consult the factory for


additional drum and hydraulic
motor options.

PACR WINCH DIVISION


P.O. Box 547 Broken Arrow, Oklahoma 74013
PHONE: (918) 251-8511 FAX: (918) 259-1575

www.paccarwinch.com

CH210-01

LIT2059 REV1
NOV. 2001

CH210-01

ROPE
SIZE
(in.)

3/4

7/8

LAYER

PERFORMANCE INFORMATION

1
2
3
4
5
6
7
1
2
3
4
5
6

090 MOTOR

110 MOTOR

120 MOTOR

9.02 CU. IN. DISP. - 3000 PSI @ 125 GPM*

11.03 CU. IN. DISP. - 3000 PSI @ 155 GPM*

12.04 CU. IN. DISP. - 3000 PSI @ 170 GPM*

(148 CC DISP. - 207 bar @ 473 LPM*)

(181 CC DISP. - 207 bar @ 587 LPM*)

(197 CC DISP. - 207 bar @ 643 LPM*)

LINE PULL

LINE SPEED

LINE PULL

LINE SPEED

LINE PULL

LINE SPEED

NOTES
ROPE
CAPACITY

(LBS)

(KG)

(FPM)

(MPM)

(LBS)

(KG)

(FPM)

(MPM)

(LBS)

(KG)

(FPM)

(MPM)

ft

14,780
13,490
12,410
11,490
10,700
10,010
9,400
14,660
13,200
12,010
11,020
10,170
9,450

6,704
6,119
5,629
5,212
4,854
4,541
4,264
6,650
5,988
5,448
4,999
4,613
4,287

344
377
410
443
475
508
541
347
385
423
462
500
538

105
115
125
135
145
155
165
106
117
129
141
152
164

18,580
16,970
15,610
14,450
13,460
12,590
11,830
18,440
16,610
15,110
13,860
12,800
11,890

8,428
7,698
7,081
6,555
6,105
5,711
5,366
8,364
7,534
6,854
6,287
5,806
5,393

349
382
416
449
482
515
549
352
391
429
468
507
546

106
116
127
137
147
157
167
107
119
131
143
155
166

20,490
18,710
17,210
15,940
14,840
13,880
13,040
20,330
18,310
16,650
15,280
14,110
13,100

9,294
8,487
7,806
7,230
6,731
6,296
5,915
9,222
8,305
7,552
6,931
6,400
5,942

351
384
418
451
485
418
552
354
393
432
471
510
549

107
117
127
137
148
127
168
108
120
132
144
155
167

109
228
358
498
649
810
982
94
199
314
439
575
721

33.2
69.5
109
152
198
247
299
28.7
60.7
95.7
134
175
220

Specifications are subject to change without notification and without incurring obligation.
Pressure and flow shown are the maximum
allowable for the particular combination of winch,
ratio, motor and drum.
Specifications in this publication are theoretical
and may vary depending on hydraulic system,
environment, etc.
Line pulls are maximum ratings for the winch
only. Wire rope ratings may be lower than the
winch rating. Consult the wire rope manufacturer for ratings

*Consult factory for flows above 120 GPM (454 LPM)

TWO SPEED MOTOR

SIZE
(in.)

3/4

7/8

HIGH SPEED

12.74 CU. IN. DISP.- 2650 PSI @ 85 GPM

6.38 CU. IN. DISP.- 2500 PSI @ 85 GPM

(209 CC DISP. - 183 bar @ 322 LPM)

(105 CC DISP. - 172 bar @ 322 LPM)

LAYER

ROPE

LOW SPEED

(LBS)

(KG)

(FPM)

(MPM)

(LBS)

(KG)

(FPM)

(MPM)

1
2
3
4
5
6
7
1
2
3
4
5
6

21,400
19,540
17,970
16,640
15,490
14,500
13,620
21,400
19,270
17,530
16,080
14,850
13,790

9,707
8,863
8,151
7,548
7,026
6,577
6,178
9,707
8,741
7,952
7,294
6,736
6,255

158
173
188
204
219
234
249
160
177
195
212
230
248

48
53
57
62
67
71
76
49
54
59
65
70
76

9,690
8,850
8,140
7,540
7,020
6,570
6,170
9,690
8,730
7,940
7,280
6,730
6,250

4,395
4,014
3,692
3,420
3,184
2,980
2,799
4,395
3,960
3,602
3,302
3,053
2,835

324
355
386
417
448
479
510
327
363
399
435
471
507

99
108
118
127
137
146
155
100
111
122
133
144
155

LINE PULL

LINE SPEED

MINIMUM FLOW RECOMMENDATION


FOR SMOOTH OPERATION
(RECOMMENDED MINIMUM SYSTEM FLOW
SHOULD BE 2X THESE VALUES)

LINE PULL

LINE SPEED

MOTOR

GPM

090

24

91

110

27

102

120
128/064

LPM

28
106
CONSULT FACTORY

OPTIONS
Consult the factory for high
pressure piston motors and
available ratios.

WARNING
CAUTION

A minimum of 5 wraps of wire rope


must be left on the drum to prevent
the load from being supported by
the wire rope anchor alone. Since
the wire rope anchor is not
designed to hold the rated load, failure to leave 5 wraps of wire rope on
the drum could cause the load to
drop, which could result in property
damage, injury or death.

COMMITMENT
Every process in the design, manufacture and support of BRADEN products is focused on one goal:
Providing the highest quality winch, hoist and drive
systems in the world. PACCAR Winch Division is
committed to providing the best in product functionality and reliability.
Since 1905 PACCAR Inc has provided high quality
products and services to numerous markets and
countries. Let us put our experience and expertise
to work for you.

CH210A - 02 DRUM

20,000 LB First Layer Line Pull


DIMENSIONAL INFORMATION
SPLIT FLANGE

C
4.65

31.98

30.75

HOIST

15.38

HOIST

15.99
27.5

16.0

4.81

1.31
1.13
28.0

0.16
1.12
2.38

HOIST PORT
SAE 1.50 CODE 61
SPLIT FLANGE

14.25
LOWERING PORT
SAE -16 ORB
(1 5/16-12 THD)

1.03
3.12

3.75

MOUNTING HOLES
MOUNTING HOLES
X 1.06
1.06 DIAM.
DIAM.THRU
THRU
44 X

19.21

3.38
38.37

MOTOR
090
MOTOR
110
110
120
120
090
128/064
128/064

A
B
5.38
A
B
C7.50
5.63 7.75 50.69
5.63
7.75
5.75 7.88 50.82
5.75
7.88
5.38 7.50 50.44
8.56
10.56
8.56 10.56 55.69

C
50.44
50.69
50.82
55.69

5.29
TYP.

5.81

10.5
21.0

LOWER PORT
SAE 1.50 CODE 61
SPLIT FLANGE

HOIST

Increased line pull ratings to better utilize higher strength wire ropes
Gearing is designed for improved service life at higher input RPM and higher
input torque
New brake design increases allowable input RPM, overrunning clutch capacity
and oil flow to the brake
SAE C and D motor mounts for improved hydraulic motor compatibility
Optional electronic rotation sensor
Same mounting hole locations and envelope size as the CH185A
Improved serviceability
COPYRIGHT 2002
PACCAR WINCH DIVISION

PRINTED IN U.S.A.

HOIST PORT
SAE -16 ORB

5.50

2 SPEED
SHIFT PORT

4.22

2-SPEED MOTOR

MOTOR OPTIONS
090 9.02 cu in.
110 11.03 cu in.
120 12.03 cu in.
128/064 12.76/6.38 cu in. (2 speed)

Consult the factory for


additional drum and hydraulic
motor options.

PACR WINCH DIVISION


P.O. Box 547 Broken Arrow, Oklahoma 74013
PHONE: (918) 251-8511 FAX: (918) 259-1575

www.paccarwinch.com

CH210-02

LIT2060 REV3
OCT. 2002

CH210-02

ROPE
SIZE
(in.)

3/4

7/8

LAYER

PERFORMANCE INFORMATION

1
2
3
4
5
6
7*
1
2
3
4
5
6*

090 MOTOR

110 MOTOR

120 MOTOR

9.02 CU. IN. DISP. - 3000 PSI @ 125 GPM**


(148 CC DISP. - 207 bar @ 473 LPM*)

11.03 CU. IN. DISP. - 3000 PSI @ 155 GPM**


(181 CC DISP. - 207 bar @ 587 LPM*)

12.04 CU. IN. DISP. - 3000 PSI @ 170 GPM**


(197 CC DISP. - 207 bar @ 643 LPM*)

LINE PULL

LINE SPEED

LINE PULL

LINE SPEED

LINE PULL

LINE SPEED

(LBS)

(KG)

(FPM)

(MPM)

(LBS)

(KG)

(FPM)

(MPM)

(LBS)

(KG)

(FPM)

(MPM)

13,890
12,750
11,780
10,950
10,230
9,600
9,040
13,790
12,500
11,420
10,520
9,750
9,080

6,301
5,783
5,343
4,967
4,640
4,355
4,101
6,255
5,670
5,180
4,772
4,423
4,119

366
399
432
465
497
530
563
369
407
445
484
522
560

112
122
132
142
151
162
172
112
124
136
148
159
171

17,470
16,040
14,820
13,770
12,870
12,070
11,370
17,340
15,710
14,370
13,230
12,260
11,420

7,924
7,276
6,722
6,246
5,838
5,475
5,157
7,865
7,126
6,518
6,001
5,561
5,180

371
404
438
471
504
538
571
374
413
452
490
529
568

113
123
134
144
154
164
174
114
126
138
149
161
173

19,270
17,680
16,340
15,190
14,180
13,310
12,530
19,120
17,330
15,840
14,580
13,520
12,590

8,741
8,020
7,412
6,890
6,432
6,037
5,684
8,673
7,861
7,185
6,613
6,133
5,711

373
407
440
474
507
541
574
376
415
454
493
532
571

114
124
134
144
155
165
175
115
126
138
150
162
174

* This layer does not comply with ANSI standard B30.5 for 1/2 inch exposed flange.

NOTES
ROPE
CAPACITY
ft

186 56.7
389 119
609 186
846 258
1,099 335
1,369 417
1,656 505
161 49.1
339 103
533 162
744 227
972 296
1,217 371

Specifications are subject to change without notification and without incurring obligation.
Pressure and flow shown are the maximum
allowable for the particular combination of winch,
ratio, motor and drum.
Specifications in this publication are theoretical
and may vary depending on hydraulic system,
environment, etc.
Line pulls are maximum ratings for the winch
only. Wire rope ratings may be lower than the
winch rating. Consult the wire rope manufacturer for ratings

** Consult factory for flows above 120 GPM (454 LPM)

ROPE
SIZE
(in.)

3/4

7/8

LAYER

TWO SPEED MOTOR

1
2
3
4
5
6
7*
1
2
3
4
5
6*

LOW SPEED

HIGH SPEED

12.74 CU. IN. DISP.- 2920 PSI @ 85 GPM


(209 CC DISP. - 201 bar @ 322 LPM)

6.38 CU. IN. DISP.- 2920 PSI @ 85 GPM


(105 CC DISP. - 201 bar @ 322 LPM)

LINE PULL

LINE SPEED

LINE PULL

LINE SPEED

(LBS)

(KG)

(FPM)

(MPM)

(LBS)

(KG)

(FPM)

(MPM)

20,120
18,470
17,060
15,860
14,810
13,900
13,090
19,970
18,090
16,540
15,230
14,120
13,150

9,126
8,378
7,738
7,194
6,718
6,305
5,938
9,058
8,206
7,503
6,908
6,405
5,965

168
183
199
214
229
244
259
170
187
205
223
240
258

51
56
61
65
70
74
79
52
57
62
68
73
79

9,110
8,360
7,730
7,180
6,710
6,290
5,930
9,050
8,200
7,490
6,900
6,390
5,960

4,132
3,792
3,506
3,257
3,044
2,853
2,690
4,105
3,720
3,397
3,130
2,899
2,703

345
376
406
437
468
499
530
347
383
419
455
491
528

105
115
124
133
143
152
162
106
117
128
139
150
161

* This layer does not comply with ANSI standard B30.5 for 1/2 inch exposed flange.

MINIMUM FLOW RECOMMENDATION


FOR SMOOTH OPERATION
(RECOMMENDED MINIMUM SYSTEM FLOW
SHOULD BE 2X THESE VALUES)

MOTOR

GPM

090

24

91

110

27

102

120
128/064

LPM

28
106
CONSULT FACTORY

OPTIONS
Consult the factory for high
pressure piston motors and
available ratios.

WARNING
CAUTION

A minimum of 5 wraps of wire rope


must be left on the drum to prevent
the load from being supported by
the wire rope anchor alone. Since
the wire rope anchor is not
designed to hold the rated load, failure to leave 5 wraps of wire rope on
the drum could cause the load to
drop, which could result in property
damage, injury or death.

COMMITMENT
Every process in the design, manufacture and support of BRADEN products is focused on one goal:
Providing the highest quality winch, hoist and drive
systems in the world. PACCAR Winch Division is
committed to providing the best in product functionality and reliability.
Since 1905 PACCAR Inc has provided high quality
products and services to numerous markets and
countries. Let us put our experience and expertise
to work for you.

Vous aimerez peut-être aussi