DWH8040

Please check your controller label. Depends on your order the power supply (operating voltage) could be either 110V, 220V or 12V Specification:
Humidity Measuring Range: 5% ~ 99% RH Humidity controlling range: 5% ~ 95% RH Resolution: 1 % RH Accuracy: 5%RH 10%RH~95%RH25 ) Sensor Type: HS31K Power consumption: < 3W, Max 200mA Relay output Current: 10A / 110V , 10A/12V , 5A/220V Temperature compensation: YES Sensor operating temperature range: -30~+80 Temperature coefficient: 0.2%RH/ Extended stability: R0.5%RH/yr Data Retention: Yes Working temperature: 0C - 50 C Storage temperature: -10C - 60 C Size: 78 x 71 x 29 mm ( L*W*H ) Weight: 200 g Install Window Size: 70 x 28 MM

Key Notes RST: press key RST to switch starting up and power off, on the condition of power off, it can start up when press key RST, on the condition of starting up, it can power off when press and hold the key RST for three seconds. SET: press key set to enter setting of humidity control, and press key or to adjust. Press and hold key or for three seconds to enter the fast adjust mode. Press key SET again to exit setting mode. Press and hold key SET for three seconds to enter the system menu setting, and press key or (up or down) to select the adjustment menu. Press key SET again to enter the corresponding parameter setting, and press key or to adjust the parameters need to modified, after the adjustment, press key RST to exit or after 5 seconds it will exit.

Operating instructions
How to amend a Parameter Setting When you enter one of the Menus as described above you will be presented with the first setting to be updated. By pressing the UP and DOWN keys you can scroll through each one of the Parameter Setting Codes. Once you have selected the parameter you wish to change press the SET key and the display will now show the setting for that parameter. Press the UP and DOWN keys to select the new setting then press SET key to accept the new setting. Once you have updated the new settings you need to save them by pressing the SET key. Please note that if you do not press any key for less than 30 seconds, any updates to any of the parameters will not be saved. Indicator condition description The light work on the left side of display screen is used as working indicator, when it twinkles, which means humidification or dehumidification delay, and LED normally on means the function of humidification or dehumidification is working. The light SET on the left side of display screen is used as set indicator, and LED normally on means in the set condition. Function Declaration Press key RST to start up the humidity controller, while operating, press and hold this key for 3 seconds, and it can turn off the humidity controller. Function of humidification or dehumidification Dehumidification mode: When the measured humidity value is set value + difference value, relay output is on and when humidity value is set value + difference value, relay output is off and disconnected.

Humidification mode: When the measured humidity value is set value + difference value, relay output is on and when humidity value is set value + difference value, relay output is off and disconnected.

Delay protection
The delay in minutes when the Output Relay will switch on after being requested to come on. For example if it was set to 3 Minutes then as soon as the Output Relay is requested to be switched on it will wait 3 minutes before coming on. The working indictor will flash on and off to indicate that the relay is due to come on but is waiting. The light will become solid when the time delay is finished and the relay switches on. This is a safety feature to protect the device that is connected to the unit from continual switching and causing damage. If its set to 0 then there will be no time delay.

Setting of Delay Protection Press and hold key SET for more than 3 seconds to enter the menu display, and press key or to make display screen appear PI code, then press SET to display the set value of delay protection, and then press key or to adjust parameters. Function of upper and lower limit Setting of HS and LS limit the range of humidity point controlling, for example, HS is set to +15 and LS is set to -10, so the temperature set point can only be between -10 to +15. If the display screen shows -10, press key and the display value will not decrease. Setting of humidification or dehumidification mode. Setting of upper and lower limit Press and hold key SET for more than 3 seconds to enter the menu display, and press key or to make display screen appear HS or LS code, then press key SET to display the set value of upper or lower limit and then press key or to adjust parameter. Press and hold key SET for more than 3 seconds to enter the menu display, when the screen appears HC code , press key SET to show the working mode, and then press key or to adjust the display, in which C means dehumidification mode and H means humidification mode. Difference value setting Press and hold key SET for more than 3 seconds to enter the menu display, and press key or to make display screen appear D code, then press key SET to display the difference value and press key or to adjust parameter. Humidity correction If there is difference between measured humidity and standard humidity, you can use humidity correction key. Correction value can be positive, negative or 0. Setting of humidity correction Press and hold key SET for more than 3 seconds to enter the menu display, and press key or to make display screen appear CA code, then press key SET to display the set value of humidity correction and press key or to adjust parameter.

Parameter Menu and Settings


Signs HC D LS HS CA PT Details Humidification/Dehumidification Difference value Limits on minimum setting Limit on maximum setting Humidity correction Delay time Setting range H/C 1-15 % 1-99 % 1-99 % -7 to +7 0-7 Factory Setting C 5 % 5 % 95 % 0 % 1 minute

Error Messages The following error message will show to indicate that there is a fault. - - -: When disconnect the sensor or there is a loose connection, display screen shows --- and make alarming sound HH: Humidity is out of range for displaying (higher limit) LL: Humidity is out of range for displaying (Lower limit) Additional Information Please avoid using the sensor in dusty environments. Do not submerge the humidity sensor in water or liquid. The temperature sensor (NTC sensor) being used to calculate humidity more precise depending on the temperature inside of the house and it should be installed in the vicinity of the humidity probe. Be sure to wire power, relay output, humidity sensor and NTC sensor to correct terminal according to your wiring diagram, otherwise it will damage the controller.