Motor Protectors 1070-1071 Current Sensors 1071-1072 Transformers 1072-1073 Fan Centers 1073-1074 Switching Relays 1074-1077 Definite Purpose Contactors 1078-1081 Submeters 1082-1083 Variable Speed Drives 1084-1088 Motor Starters 1089 Motor Start Assists 1089-1091 Potential, Current Relays 1092 Overloads 1093 Capacitors 1093-1095 Disc Temperature Controls 1096 Disc Fan/Limit Controls 1096-1098 Electric Heat Sequencers 1099 Heaters 1100-1102 Crankcase, Drain Disconnects 1103 Fuses 1104-1106 Electrical Connectors, Accessories 1007-1111 Wire 1111-1115
Heating Controls
Gas Valves 958-965 Pilots, Thermocouples 965-968 Ignition Modules, Retrofits 969-974 Flame Sensors, Ignitors 975-976 Gas Regulators 977-978 Warm Air Controls 978-981 Reversing Valves 982 Hydronic Controls 983-985 Zone Valves 986-990 Hydronic Panels 991-992 Oil Burner Controls 992-993, 999-1000 Flame Safeguard 994-998 Pilot, Commercial Gas Valves 1000-1003 Appliance Controls, Gas, Electric 1003
891
Page 901
901
897
902
917
895
CONTROLS & ELECTRICAL ACCESSORIES
895
895
898
See PSGs website www.psgcontrols.com for product search and detailed product specifications OR Call PSGs Customer Service 800-782-8412
CUSTOMER SERVICE CENTER ... 888-578-9100
892
Page 915
915
897
898
897
893
894
THERMOSTAT
ACCUSTAT, DIGITAL
ACCUSTAT INDEPENDENCE
ACCUSTAT, ELECTROMECHANICAL
ACCUSTAT
Mercury free alternative to the original Accustat series Use the same locking cover design and fit the same applications as the original low voltage Accustat models. Requires Accustat Independence MERCURY FREE preset setpoints (sold separately) Common wire capability present (but not required) Ideal for commercial applications and multi-unit dwellings where owner control of comfort setting is required. Locking case: requires special key to open (provided with each control) Easy to install - same wiring as the bi-metal thermostat or original Accustat series thermostat Precise temperature control - accuracy of 1 with Accustat Independence setpoints Voltage: 20-32VAC Cycle Rate: 6 cycles per hour Load Rating: 1.5 amp maximum per circuit Differential - selectable by switch - 0.5or 1
Sensors Required 1 1 2 2 2 4 4 Switching System On/Off On/Off On/Off On/Off, Hi/Lo H/O/C H/O/C; Hi/Lo H/O/A/C
Accustat single-stage control uses preset or adjustable Accutherm snap-in sensors Save energy, up to 15% over the conventional bi-metal thermostats Ideal for commercial applications and multi-unit dwellings where owner control of comfort setting is required Locking case: Requires special key to open (provided with each control) Easy to install: Same wiring as the bi-metal thermostat Tamper resistant: Temperature settings cannot be adjusted when preset sensor is used. LMSAH22NS has concealed switches Precise temperature control: No leveling and no anticipators to adjust Voltage: 1826 Vac Differential: Approximately 2F depending on air flow Sensors are packaged and sold separately. Specify temperature setpoints when ordering
ACCUSTAT LOW VOLTAGE SINGLE STAGE
Sensors Switching System On/Off On/Off On/Off, Hi/Lo H/O/C H/O/C H/A/C; On/Off Fan A/O A/O A/O A/O Price 68.78 68.78 72.42 89.94 87.36 103.68 Part No. LA1 LH1 LH2 LAH11 LAH11E LMSAH11 Application Cool Only Heat Only Heat Only Cool/Heat Cool/Elect Heat Cool/Heat Required 1 1 2 2 2 2
Application Cool Only Heat Only Cool Only Heat Only Cool/Heat Cool/Heat 2 Cool/2 Heat
LMSAH22 LHPAH22
4 4
A/O A/O
132.26 175.04
Part No. T 40 T 45 T 50 T 55 T 60 T 62 T 64 T 65 T 66 T 68 T 70 T 72 T 74 T 75 T 76 T 78 T 80
Price 17.22 17.22 17.22 17.22 17.22 17.22 17.22 17.22 17.22 17.22 17.22 17.22 17.22 17.22 17.22 17.22 17.22
ACCUSTAT ACCESSORIES
CP012 Part No. CP012 CP 012I CP012E CP013 CP014 T247 Description Accustat Thermostat Cover Accustat Independence Locking Cover E-Accustat Locking Cover Accustat Locking Pins (2) Accustat Key E-Accustat 24 VAC 7-Day Programmable Timer Price 7.14 10.00 10.00 2.54 3.28 61.81
Designed to work with the Accustat Independence line of thermostats, these MERCURY FREE setpoints provide fixed temperature setting with an accuracy of 1, making them ideal for apartments, condos, and other managed properties.
LHPAH22 is specifically for 2 stage heat, 1 stage cool heat pumps with a sensor for the reversing valve (handles heat or cool energizing modes)
Application/ Part No. LMSA2 Stages 2C Sensors Required 2 Switching System On/Off Fan A/O Price 84.26
895
THERMOSTAT
ELECTROMECHANICAL, SINGLE SETPOINT
Mercury sensors may not be available in all locations. Call your local United Refrigeration branch for additional information
ACCUTHERM ADJUSTABLE MERCURY SENSOR
Part No. T812A1002 Application Heating Only
ELECTROMECHANICAL
HEAT ONLY , T812 SERIES
Provides SPST control of 24 Vac residential heating systems. Coiled bimetal element operates snap-action switch
Temperature Range (F) 5090 Finish Premier White Price 23.40
Accutherm sensors are used in the original Accustat temperature controls. They have solder rings which snap into S68 the fuse clips of the Accustat . The "S" Series are preset and cannot be adjusted. They have an accuracy of 1.0F and a differential (air) of 1.5/2F. The AS90 is adjustable over a range of 40 to 90F, with an accuracy of 1F and a differential (air) of 2/3F. Accutherm sensors are unaffected by vibration, are not position sensitive, and are hermetically sealed. 100 milliamps maximum resistive load.
Part No. S40 S45 S50 S55 S60 S62 S64 S65 S66 S68 S70 S72 S74 S75 S76 S78 S80 Temperature Setting (F) 40 45 50 55 60 62 64 65 66 68 70 72 74 75 76 78 80 Price 42.69 42.69 42.69 42.69 42.68 35.28 35.28 35.28 35.28 35.28 35.28 35.28 35.28 35.28 35.28 35.28 35.28
Low voltage thermostat Vertical mounting Coiled bimetal element operates snap action switch T822K1000 SPST switch Vented covers-better air flow-improved temperature sensing Premier White color T827K provides control of 0.1A circuits in millivoltage, 12 VDC, and 24 Vac heating systems. T822L is heat only for normally open hot water zone valves T822L: scale in Farenheit and Celcius
Stages Part No. T822K1000 T822K1042 T822L1000 T827K1009 T834N1002 Heat 1 1 1 1 Cool 1 1 Temperature Range (F) 45 to 95 35 to 85 45 to 95 50 to 90 50F to 90F Price 54.64 54.64 52.84 50.30 53.64
SNAP ACTION
For low voltage single stage heating and cooling installations where a snap-action control is desired. Voltage: mV to 30 Vac maximum Snap action contacts Vertical orientation Bi metal thermometer 1C26101 includes "A" terminal for electric heat systems
Switch Functions Part No. 1C20 102 1C26101 Orientation Vertical Vertical System H/O/C Fan A/O Application Heating Heat/Cool Price 22.88 23.46
SNAP ACTION
For low voltage heating, cooling, and zoning installations where a snapaction control is desired. Voltage: 30 Vac maximum Snap action contacts Vertical orientation Suitable for zoning applications
Part No. 1E30N910 Range (F) 50 to 90 Switch SPST Open Rise Application Heating Price 50.76
896
THERMOSTAT
HEAT/COOL OCCUPANCY SENSING
Single stage heating/cooling Voltage: 30 Vac maximum Switching: C/O/H, A/O Temperature range: 50 to 90F 1E56N444 SPDT Contact Type: enclosed snap switch Bi-metal thermometer Mercury free
Part No. 1E56N444 1F56N444 Mount* V H Comments Terminals B,O,A, 1Stage HP , Electric Heat Terminals B,O,A, 1Stage HP , Electric Heat Price 51.52 51.52
*Horizontal/Vertical
HEAT/COOL, SUB-BASE
The occupancy sensing thermostat provides a wall mounted option for economical function in fan coil, PTAC, PTHP and water source heat pump systems. The motion delay time is field configurable as well as default setpoint, comfort limits, differential and cycle rates. Automatic system changeover is standard. Specifications: Input voltage: 24 Load rating: 1.5 max amp/circuit Occupancy sensor: passive infrared Dimensions: 3.5"W x 5.0"H x 1.5"D
Part No. OS 1 Temperature Range (F) 60 to 85 Contact Rating (Amps) 1.5 Price 250.00
Contractor model, thermostat and subbase packaged seperately (ideal for tract applications where installation is done in stages) Includes thermostat and subbase Mercury free, environmentally safe Electric heat applications
Part No. 40042K Usage 24V, Electric Heat/Cool Price 64.50
One-touch economy setback 24 VAC 10%, 50/60 HZ (not rated for DC or millivolt systems), 0.01 to 1 Amp (per circuit) Batteries required for all installations, including optional hardwire connection. Batteries included. Single or dual transformer connections Heating and/or cooling for single stage gas, oil, electric, or heat pump systems Easy-to-read backlit display Multiple lockout levels Setpoint temperature range: 40F to 90F (4.5C to 32C) Selectable auto-changeover or manual modes Adjustable independent heat/cool cycle rates, differentials and limits ServiceWatch Monitor System: filter, heating and cooling run time monitoring
Part No. F 100 Function 1 Cool/1 Heat Power Method Battery or Hardwire Price 92.62
Designed for water source Heat Pump, PTAC, and PTHP systems with 2 fan speeds. (May also be suitable for some fan coil systems.) These controls are equipped with flexible programming options that allow the installer (or property owner) to set a variety of features, such as PTAC manufacturer comfort limits, cycle rate, etc. For highly corrosive environments such as high humidity, salty air, dusty air, etc., it is highly recommended that controls be ordered with conformal coating (add a "K" after "NP" in the part number). Specifications: Voltage: 24 Range: 60F to 85F Accuracy: 1F Comfort limits: 60F to 85F Economy limits: Cool 78F to 88F, Heat 55F to 68F Temperature setting and fan selection: push button Case: flame retardant, high impact plastic, white or tan Cycle rate: adjustable, 0 to 24 cycle/hr. Dimensions: 3.5"W x 5.0"H x 1.5"D
NP 4505A SB1 SB1E KF 1 170.00 15.50 16.12 57.01
Part No.
Description Digital HP/PTAC with backlight - auto changeover Subbase for Nepra 4000/4500, No Instructions Subbase for Nepra 4000/4500, U Model Instructions
Price
897
THERMOSTAT
DIGITAL, NON PROGRAMMABLE
NEPRA WIRELESS SERIES E-ACCUSTAT II
The Nepra wireless series provides a wall mounted option for PTAC and PTHP systems without the hassle of running wires. A battery-operated control is mounted on the wall, and a receiver is wired directly into the system equipment. These controls are equipped with flexible programming options that allow the installer (or property owner) to set a variety of features, such as PTAC manufacturer comfort limits, cycle rate, etc. Thermostat Basic Specifications: Input voltage: 2 C-cell batteries (3V total) Load rating: 0.5 amp/circuit Range: 60F to 85F Accuracy: 1F Case: flame retardant, high impact plastic, white or tan Dimensions: 3.5"W x 5.0"H x 1.5"D Receiver Basic Specifications: Input voltage: 24 VAC Load rating: 0.1 amp/circuit Dimensions: 2.5"W x 4.4"H x 1.1"D
Part No. RFU Fan Control User Selectable Price 496.00
The E-ACCUSTAT II, with adjustable electronic sensing, does not require sensors, as the electronic sensing is built into the control. Wiring is the same as the pre-set ACCUSTAT or any conventional thermostat, just set the temperature and place the locking cover on the base. Features: Adjustable Cycle Rates--Heating and cooling cycle rates can be set independently. Locking Cover--Provides tamper resistant operation. Special key needed to open the cover (included). Intelligent Fan Switching--Auto/On - when control is in un-occupied mode fan operation switches to auto. Specifications: Voltage: 24 VAC Temperature Range: 55 to 85F Accuracy: 1F Contact rating: 1.5A per circuit Dead Band Adjustable: 1 to 5F. Dimensions: 4.6"W x 4.6"H x 1.8"D
Part No. LEMS2AH11 LEMS2AH22 Stages Heat Cool 1 1 2 2 Switching System Fan H/A/C A/O H/A/C A/O Price 288.32 294.42
SEA BREEZE
Larger lighted display Simple quick reference instructions Permanent memory during power outages Dimensions: 5.3"W x 3.7"H x 1.2"D Set point temperature range: 45F to 90F (7C to 32C)
Part No. Application Gas, Oil, Electric (mV compatible)
Rated differential: 1/2F to 1 1/2F Electrical rating: 20 to 30 Vac, 50/60 Hz, 0.05 to 1.0 Amps (load per terminal) Operating ambient temperatures: 32F to 105F (0C to 40C) Operating humidity range: 90% non-condensing maximum No leveling required
Stages Heat Cool 1 1 Terminals C,W,B,Rh,G,Y,O,Rc Price 58.56
TSN11X
FOCUSPRO 5000
The FocusPRO non-programmable thermostat provides electronic control of 24 Vac, single-stage heating and cooling systems or 750 mV heating systems. Large, clear, backlit display: Easy-to-see and read even in the dark. Precise comfort control: 1F of your set temperature.
Part No. TH5110D1006 TH5110D1022 TH5220D1003 TH5220D1029 TH5320U1001 Application Gas, Oil, Electric, mV Gas, Oil, Electric, mV Gas, Oil, Electric, Heat Pump, mV Gas, Oil, Electric, Heat Pump, mV Gas, Oil, Electric, Heat Pump, mV Power Method Battery and Hardwire Battery and Hardwire Battery and Hardwire Battery and Hardwire Battery and Hardwire Display 1.95 sq. in. 2.98 sq. in. 3.75 sq. in. 5.09 sq. in. 5.09 sq. in.
Simplified operation: Soft-key controls. Simultaneously displays both room temperature and temperature setting. Easy change battery holder. Built-in compressor protection: Minimum-off timer protects compressor from restarting too early after a shutdown.
Stages Heat Cool 1 1 1 1 2 2 2 2 3 2 Switching System H/O/C/A H/O/C/A H/O/C/A/EM H/O/C/A/EM H/O/C/A/EM Fan A/O A/O A/O A/O A/O Price 85.74 100.52 120.84 139.16 157.46
898
THERMOSTAT
FOCUSPRO WIRELESS
Easily add a zone to a TrueZONE system without running new wires. Powered by RedLINK reliability No interference with other wireless devices in the home Works with compatible RedLINK enabled devices Large, clear, backlit display: Easy-to-see and read even in the dark.
Part No. TH5320R1002 THM5320R1000
Precise comfort control: 1F of your set temperature. Simplified operation: Soft-key controls. Simultaneously displays both room temperature and temperature setting. Easy change battery holder. Built-in compressor protection: Minimum-off timer protects compressor from restarting too early after a shutdown. Changeover: automatic or manual
Power Method Battery Stages Heat Cool 3 2 Switching System Fan H/O/C/A/EM A/O Price 253.66 252.94
Application Gas, Oil, Electric, Heat Pump, Forced Warm Air, Hot Water, Steam or Gravity
PRO 3000
The PRO 3000 non-programmable thermostat provides electronic control of 24 Vac, single-stage heating and cooling systems or 750 mV heating systems. Horizontal mounting Manual changeover Large, clear backlit display is easy to read, even in the dark
Part No. TH3110D1008 TH3210D1004 Application Conventional Conventional, HP Power Method Battery and Hardwire Battery and Hardwire Display 1.32 sq. in. 1.32 sq. in.
One-touch temperature controls Switchable fan control (auto or continuous fan) Displays both room temperature and temperature setting Built-in compressor protection Voltage: 20 30, 750 mV
Switching System Fan C/O/H A/O C/O/H/EM A/O
Voltage: 20 to 30 Vac
TH1210D Power Method Battery or Hardwire Battery or Hardwire Battery or Hardwire Stages Heat Cool 1 1 2 1 1 Switching System Fan H/O C/O/H C/O/H/EM A/O A/O
Display 1.32 sq. in. 1.32 sq. in. 1.32 sq. in.
DIGITAL ROUND
The T8775A thermostat provides 24V control of heating only systems. The T8775C thermostat provides single-stage temperature control for T8775C1005 24V heating-cooling systems with manual changeover from heat to cool. Includes wall plate, screws, and anchors. Range: 40 to 90F heating, 45 to 99F cooling 1.5A maximum system, .5A maximum fan, 20 to 30 Vac Large easy-to-read, backlit display
Part No. T8775A1009 T8775C1005 Heat 1 1
No batteries required; permanent retention of settings in power failure Powered through heating-cooling system controls Manual changeover, system, fan switches T8775C Easily configurable by the use of DIP switches F or C temperature display Selectable heating cycle rates (1, 3, 6, 9 cph) for a variety of applications Cooling cycle rate is fixed at 3 cph Premier White color
Stages Cool 1 Price 85.54 97.98
899
THERMOSTAT
DIGITAL, NON PROGRAMMABLE
THE ROUND, ELECTRONIC
Provide electronic control of 24 Vac heating and cooling systems. Mercury free Manual changeover Thermistor sensor element
Part No. T87K1007 T87N1000 T87N1026 Scale Range (F) 40 to 90 40 to 90 40 to 90 Terminals R,W,Y R,Rc,W,Y,G,O,B R,Rc,W,Y,G,O,B Finish Premier White Premier White Premier White Comments Heat Only Heat, Cool Heat/Cool, Easy to See, Raised Markings, 2 click Price 61.26 89.66 108.94
RS4200 SERIES
With the comfort, convenience, and efficiency features that homeowners and contractors want, the RS4000 family provides custom program RS4110 options in value-packed thermostats for an affordable price. Quick connect wiring feature to save up to 15 minutes on every installation. Pop-up Wizard to customize thermostat settings with an instant start-up menu.
Stages Part No. RS4110 RS4220 Heat 1 2 Cool 1 2
Fully adjustable differentials to maintain optimal heating and cooling comfort year-round. All RS4000 thermostats are fully compatible with all standard 24V AC heating and cooling systems. Additional compatibility with multi-stage gas/electric furnaces and heat pump systems is available in the RS4220 model.
Application Gas, Electric, Oil, Heat Pump, mV Gas, Electric, Oil, Heat Pump, mV
RS2200 SERIES
HEAT/COOL, 80 SERIES
The RS2000 family provides custom program options in value-packed thermostats for an affordable price. Bigger, brighter backlight RS2210 Front load battery door for simple replacement Fully adjustable differentials for increased comfort control Worry free EPROM memory retention (RS2210 only) Filter monitor All RS2000 thermostats are fully compatible with all standard 24V AC heating and cooling systems.
Part No. RS2110 RS2210 Stages Heat Cool Application 1 1 Gas, Electric, Oil, Heat Pump, mV 2 1 Gas, Electric, Oil, Heat Pump Comments Battery Hard Wire, Battery Backup Price 52.74 69.74
Hardwired (1F89), Hardwired or battery (1F83) Fossil fuel or electric heat compatible 1F83261 Large LCD display with backlight Permanent program retention during power loss Configuration menu allows keypad selection of options Selectable C or F temperature display Classic White color
Stages Switching Description Heat Cool System Fan Price 2 H/O/C A/O 133.64 1F83261 Non-program, Conventional 2 2 H/O/C/EM A/O 99.50 1F89211 Non-program, Heat Pump 1 Part No.
SINGLE STAGE
Comfort-Set 70 Series 1 Heat/1 Cool. Battery powered for maximum compatibility Fossil fuel or electric heat compatible Large LCD with backlight Selectable C or F temperature display Includes O and B terminals Classic White color
Part No. 1F78144 Description Economy Staging Heat Cool 1 1 Price 53.92
900
THERMOSTAT
HEAT/COOL ECONOMY
The 1F86 digital thermostats are battery powered and compatible with most heating and cooling systems. For heating, cooling, electric heat, 1-stage heat pump Temperature range: 45 to 90F Voltage: millivolt to 30 Vac Large LCD display
Part No. 1F86344 Description Battery Powered Stages Heat Cool 1 1 Switching System Fan H/O/C A/O Price 75.80 Part No. 1E78144
Fossil fuel or electric heat compatible. Large LCD with backlight. Terminal Load: 1.0 A per terminal, 1.5A maximum all terminals combined Dimensions: 3 3/4"H x 5 1/8"W x 1 1/8"D
Stages Heat 1 Cool 1 Comments Gas, Oil, Electric, Mv, HP (1 stg) Price 53.40
BLUE, 4 UNIVERSAL
Large, 4-square-inch display with easy-to-see characters Configures as manual heat/cool, auto changeover, heat only or cool only Exclusive Cool Savings feature saves energy during peak A/C demand periods
Stages Part No. 1F86ST0471* 1F830422 1F830471 *Spanish Themostat Heat 1 2 3 Cool 1 2 2
Hydronic 2 or 3 wire applications Three anticipation settings Exclusive battery power monitor Longer battery life, 2 AA batteries included Dimensions: 5.1" W x 3.9" H x 1.2" D 0 to 30 Vac, 50/60 Hz or DC 5-year warranty
Application Gas, Oil, Electric, mV, HP Gas, Oil, Electric, mV, HP Gas, Oil, Electric, mV, HP Price 83.22 115.36 145.76
DIGITAL, PROGRAMMABLE
FREEDOM ADVANTAGE
Application Electric, Gas, Oil, A/C, Heat Pump Electric, Gas, Oil, A/C, Heat Pump Electric, Gas, Oil, A/C, Heat Pump, Programmable Fan Description Outdoor, Floor Sensor Wall Sensor
Program 7 day, 5-2 or 5-1-1 7 day, 5-2 or 5-1-1 7 day, 5-2 or 5-1-1
PSG's new residential thermostats have an attractive new look and a wealth of features to match. This easyto-use thermostat will work with single FP800 and multi-stage applications, including FP800B gas, oil, electric, and heat pump systems. It is a 24 VAC control with battery power provided for use when no hardwire is available, and the large LCD is easy to read, especially when utilizing the blue-green backlight. This thermostat is intended as the one option that can fit virtually any application!
Features: FP800 has a new and improved software Accuracy 1.0F Temperature range from 40.0F - 90.0F Configurable cooling and heating limits Keypad lockout PSG's patented ServiceWatch feature and remote sensing capabilities built-in Selectable auto or manual changeover Dimensions: 4.1"H x 6"W x 1.4"D FP710C is commercial, with programmable fan
901
THERMOSTAT
DIGITAL, PROGRAMMABLE
ACCUTOUCH
An easy-to-use programmable touchscreen thermostat Blue backlit touch screen display with intuitive user interface Single or multi-stage all-in-one equipment control, including multistage heat pump 7-day, 5-2, or 5-1-1 programmable Remote sensing capable ServiceWatch function tracks run times and service needs Multi-level display lockout Made in the USA and compliant with ARRA MADE IN THE USA Coming Soon!
Battery or hardwire Conventional or heat pump (STS11 has no aux heat control) 12 sq. inch display Auto changeover Keypad lockout Filter,humidifier pad and UV lamp reminders STS32 controls dual fuel heat pump Optional remote sensor (435-0012 Outdoor, 435-0013 Indoor)
Stages Part No. STS11 STS32 Heat 1 3 Cool 1 2 Program 5-2 5-2 Price 208.92 225.24
Includes: thermostat, receiver, table stand, battery charger, 10' charging cable, instruction manual, mounting hardware, quick release wall mount Programmable / non-programmable: 5+1+1, 5+2 or 7 day, transmits up to 300' Conventional or heat pump systems, PTAC mountable Temperature manual override, auto change over Filter reminder, low battery warning, economy and hold function, optional outdoor sensor, lockout Heat 41F to 95F; Cool 45F to 99F
Stages Part No. WTS32 Heat 3 Cool 2 Program Non-Programmable or 5+1+1, 5+2, 7 Price 292.30
4350013 Part No. 4350012 4350013 Description Outdoor Sensor, Waterproof, includes Mounting Hardware, 5' of Two Condutor Cable Indoor Sensor, Wall Mounted Plastic Case, includes Mounting Hardware, 10' of Two Condutor Cable Price 38.96 44.44
The Medallion series of digital programmable thermostats are battery powered or hard wired 24 Vac. Programming is 5/2 day. ServiceWatch feature (on select models) monitors run time and alerts customer to contact contractor's phone number for routine maintenance.
Stages Part No. TDMP24AH11 TDMP24AH11M3F Heat 1 1 Cool 1 1 Method Battery Hard-wired System C/O/H C/O/H
Large LED display System indicators Room temperature and set point display Backlit feature on hard wire models Gas, oil, electric applications
Switching Fan A/O A/O Comment Backlit, 2 Speed Fan Price 81.38
902
THERMOSTAT
SEA BREEZE
Larger lighted display Simple quick reference instructions Permanent memory during power outages Dimensions: 5.3"W x 3.7"H x 1.2"D Electrical rating: 20 to 30 Vac, 50/60 Hz, 0.05 to 1.0 Amps (load per terminal)
Part No. TSP12X THP14X Application Gas, Oil, Electric (mV compatible) Gas, Oil, Electric, Heat Pump (mV compatible) Program 5+2 5+2
Set point temperature range: 45F to 90F (7C to 32C) Rated differential: 1/2F to 1 1/2F Operating ambient temperatures: 32F to 105F (0C to 40C) Operating humidity range: 90% non-condensing maximum No leveling required
Stages Heat 1 1
Cool 1 1
RS5000 SERIES
With the comfort, convenience, and efficiency features that homeowners and contractors want, the RS5000 family provides EnergyStar and California Title 24 compliant features for an affordable price. Fully programmable with soft touch keys to easily set four events per day AND 5-2 day scheduling.
Stages Part No. RS5110 RS5220 Heat 1 2 Cool 1 2 Application Electric, Gas, Oil, Heat Pump, mV Electric, Gas, Oil, Heat Pump, mV
Pop-up Wizard to customize thermostat settings with an instant start-up menu. Vacation setpoint override to reduce energy use while away from home. The RS5000 thermostats are fully compatible with all standard 24V AC heating and cooling systems. Additional compatibility with multi-stage gas/electric furnaces and heat pump systems is available in the RS5220 model.
Program 5 + 2 Day 5 + 2 Day Comments Hard Wire or Battery Hard Wire or Battery Price 84.94 113.18
RS3200 SERIES
With the comfort, convenience, and efficiency features that homeowners and contractors want, the RS3000 family provides custom program options in value-packed thermostats for an affordable price. Bigger, brighter backlight Front load battery door for simple replacement
Stages Part No. RS3110 RS3210 Heat 1 2 Cool 1 1
Fully adjustable differentials for increased comfort control Worry free EPROM memory retention and automatic changeover (RS3210 only) Filter monitor Energy Star Vacation hold All RS3000 thermostats are fully compatible with all standard 24V AC heating and cooling systems.
Comments Battery Hard Wire, Battery Backup Price 59.92 77.80
INSIGHT
Menu driven displayconversational menus make programming so easy, you dont even need a manual Even during power outages, the 9725I2 thermostat maintains setpoint and programmed parameters Fully programmable7 day, 5/2, 5/1/1, or 24 hour programming menus
Stages Part No. 9701I2 9725I2 9825I2 Heat 1 3 3 Cool 1 2 2
Adjustable events per day2, 4, or 6 Remote indoor and outdoor sensor capablefor greater control of indoor comfort and system efficiency Temperature adjustment limitsset minimum and maximum temperature settings 9825I2 adds humidification/dehumidification control
Application Gas, Electric, Oil, H/P Gas, Electric, Oil, Heat Pump Gas, Electric, Oil, Humidity
Application Gas, Electric, Oil, Heat Pump, mV Gas, Electric, Oil, Heat Pump
903
THERMOSTAT
DIGITAL, PROGRAMMABLE
INSIGHT, SENSOR
9025I Part No. 9020I 9025I Description Indoor Sensor Outdoor Sensor Price 56.96 58.08
VISIONPRO
The TH8000 Universal Programmable Thermostats provide electronic control of 24 Vac heating and cooling systems or 750 mV heating system.
TH8110U1003
Large, clear display with backlighting; current temperature, set temperature and time are easy-to-read and all are displayed on the home screen. Menu driven programming guides you through the scheduling process, showing only necessary information and choices on each screen. Real time clock keeps time during power failure; automatically updates for daylight savings.
Power Part No. TH8110U1003 TH8320U1008 TH8320WF1029 TH8321U1006 C7089U1006 C7189U1005 Application Gas, Oil, Electric, mV Gas, Oil, Electric, Heat Pump, mV WiFi Internet Connected Gas, Oil, Electric, Heat Pump, mV Gas, Oil, Electric, Heat Pump, Humidity, mV
Armchair programming allows you to remove thermostat from wall to set the schedule. (Not available TH9421) Precise temperature control ( 1F) for reliable, consistent comfort. Multiple HOLD options allow you to modify schedule indefinitely or for a specific time. Change reminders prompt you to service or replace the air filter, humidifier pad, ultraviolet lamp or thermostat batteries. Programmable fan increases air quality when combined with a whole-house air cleaner. Outdoor temperature indication (Select Models) shows current outdoor temperature on the display to help you plan outdoor activities. Selectable auto or manual changeover
Stages Heat 1 3 3 3 Cool 1 2 2 2 Switching System H/O/C/A H/O/C/A/EM H/O/C/A/EM H/O/C/A/EM Fan A/O A/O A/O A/O Price 306.88 340.96 340.96 371.96 48.74 56.86
Method Display Battery and Hardwire 10 sq. in. Battery and Hardwire 10 sq. in. Battery and Hardwire 10 sq. in. Battery and Hardwire 10 sq. in.
FOCUSPRO 6000
TH6110
Separately programmable weekday/weekend schedules. One-touch temp control overrides program schedule at any time. EnergyStar compliant to greatly reduce your heating/cooling expenses. Large, clear, backlit display is easy to readeven in the dark.
Power Application Gas, Oil, Electric, mV Gas, Oil, Electric, mV Gas, Oil, Electric, Heat Pump, mV Gas, Oil, Electric, Heat Pump, mV Gas, Oil, Electric, Heat Pump, mV WiFi Internet Connected Gas, Oil, Electric, Heat Pump, mV Method Battery and Hardwire Battery and Hardwire Battery and Hardwire Battery and Hardwire Battery and Hardwire Battery and Hardwire Display 3.75 sq. in. 5.09 sq. in. 3.75 sq. in. 5.09 sq. in. 5.09 sq. in. 5.09 sq. in.
Displays both room temperature and temperature setting. Removable battery holder for fast, easy replacement. Built-in compressor protection. Selectable auto or manual changeover
Switching System H/O/C/A H/O/C/A H/O/C/A/EM H/O/C/A/EM H/O/C/A/EM H/O/C/A/EM Fan A/O A/O A/O A/O A/O A/O Price 127.62 139.56 161.40 172.64 190.44 247.96
904
THERMOSTAT
FOCUSPRO WIRELESS
Easily add a zone to a TrueZONE system without running new wires. Powered by RedLINK reliability No interference with other wireless devices in the home Works with compatible RedLINK enabled devices Separately programmable weekday/weekend schedules. One-touch temp control overrides program schedule at any time.
EnergyStar compliant to greatly reduce your heating/cooling expenses. Large, clear, backlit display is easy to readeven in the dark. Displays both room temperature and temperature setting. Removable battery holder for fast, easy replacement. Built-in compressor protection. Selectable auto or manual changeover Use with: HZ432 or HZ322 and THM4000R1000, or THM5320R1000
Power Part No. TH6320R1004 THM5320R1000 Application Gas, Oil, Electric, Heat Pump, Forced Warm Air, Hot Water, Steam or Gravity Description Method Battery
PRO 4000
Separately programmable weekday/weekend schedules. One-touch temp control overrides program schedule at any time. EnergyStar compliant to reduce your heating/cooling expenses. Large, clear, backlit display is easy to read. Displays both room temperature and temperature setting. Built-in compressor protection.
Power Part No. TH4110D1007 TH4210D1005 Application Conventional, Heat Pump Conventional, Heat Pump Method Battery and Hardwire Battery and Hardwire Display 1.73 sq. in. 1.73 sq. in. 1 2 Stages Heat Cool 1 1 Switching System C/O/H C/O/H Fan A/O A/O Price 78.66 102.60
Separately programmable weekday/weekend schedules. One-touch temp control overrides program schedule at any time. EnergyStar compliant to reduce your heating/cooling expenses. Large, clear, backlit display is easy to read. Displays both room temperature and temperature setting. Built-in compressor protection.
Power Part No. TH2110D1009 TH2210D1007 Application Conventional Heat/Cool Heat Pump, Heat/Cool Method Battery or Hardwire Battery or Hardwire Display 1.32 sq. in. 1.32 sq. in. 1 2 Stages Heat Cool 1 1 Switching System C/O/H C/O/H/EM Fan A/O A/O Price 65.76 85.50
www.uri.com
905
THERMOSTAT
DIGITAL, PROGRAMMABLE
PRESTIGE THERMOSTAT
Increase profit per job by including RedLINK accessories that provide comfort and convenience. RedLINK accessories include the RedLINK THX9321R5030 Internet Gateway, Portable Comfort Control (PCC), Wireless Outdoor Sensor, Wireless Indoor Sensor, TrueSTEAM humidifier with Wireless Adapter and TrueZONE zoning panel with Wireless Adapter. Configurable for residential and light commercial applications. Meets commercial code and is title 24 compliant. Light commercial - commercial language (occupied and unoccupied), schedule holidays and custom events, remote setback, economizer and time of day. Alerts and User Interactions Log - Keeps a searchable history of alerts and setting changes to the thermostat to determine if there is a system malfunction or if the issue was caused by user error. Saves time in troubleshooting and points the technician in the right direction.
Power Part No. THX9321R5030 THX9421R5013 Description/Application Prestige High Definition Touchscreen Thermostat. Conventional, Heat Pump Prestige IAQ 2-Wire High Definition Touchscreen Thermostat. Conventional, Heat Pump
Customizable Service Reminders allow dealers to remind their customers when its time to call for service, when their warranty is expiring and to provide customized alerts. USB port for transferring Installer Setup, Customizable Reminders, Custom Events and Holidays to multiple thermostats. 2 assignable outputs to control humidification, dehumidification, ventilation and a stage of heating or cooling. (3 outputs for THX9421) Precise Temperature Control ( 1F) for reliable and consistent temperature. Multiple staging options to provide comfort or energy savings. Additional features for THX9421: Control heating, cooling and IAQ equipment with only 2 wires at the thermostat. Heating, cooling and IAQ equipment wires to the Equipment Interface Module. Delta T Alerts and Diagnostics informs customers when their system is not operating as expected with instructions to contact the dealer.
Stages Display 8.06 sq. in. 8.06 sq. in. Heat 3 3 Conv. / 4 HP Cool 2 2 Switching System H/O/C/A/EM H/O/C/A/EM Fan A/O/Circulating A/O/Circulating Price 542.46 495.96
Description C7089R1013 C7189R1004 REM5000R1001 50028399001 THM6000R1002 THM5421R1013 Outdoor Temperature and Humidity Sensor for RedLINK enabled thermostats and accessories Wireless Indoor Temperature and Humidity Sensor for RedLINK enabled thermostats and accessories Personal Comfort Station. Works with compatible RedLINK enabled thermostats and accessories. Cover plate for Prestige Thermostats 7 7/8" x 5 1/2", Premier White RedLINK Internet Gateway provides remote access to any RedLINK enabled thermostat through the internet, smart phone or tablet Prestige IAQ 2.0 Equipment Interface module. RedLINK Enabled. Controls up to 4H/2C HP and up to 3H/2C Conv. Systems 108.46 77.46 185.98 20.70 201.46 108.46
RedLINK enabled to work with compatible wireless accessories. Includes touchscreen thermostat, 7 day programmable, up to 3H/2C heat pump (2H/2C conv.).
CONTROLS & ELECTRICAL ACCESSORIES
YTHX9321R5079 Part No. YTHX9321R5061 YTHX9321R5079 Description Prestige 2.0 HD Comfort System Kit Prestige 2.0 HD Comfort System Kit Includes THX9321R5030 Prestige 2.0 HD Thermostat, REM5000R1001 Portable Comfort Control, C7089R1013 Wireless Outdoor Air Sensor THX9321R5030 Prestige 2.0 Thermostat and C7089R1013 Wireless Outdoor Air Sensor Price 805.96 641.68
906
THERMOSTAT
PRESTIGE IAQ 2.0 COMFORT SYSTEM KIT
The Prestige IAQ 2.0 thermostat is a 2-wire HD color touch screen thermostat, 7 day programmable, configurable for residential and light YTHX9421R5051 commercial, up to 4 heat / 2 cool heat pump and up to 3 heat / 2 cool conventional, controls humidification, dehumidification and ventilation, provides Delta T Alerts and Diagnostics, works with the Equipment Interface Module and RedLINK accessories.
Control heating, cooling and IAQ equipment with only 2 wires at the thermostat. Heating, cooling and IAQ equipment wires to the Equipment Interface Module. All Prestige IAQ 2.0 systems come standard with a return and discharge air temperature sensor to measure Delta T. Alerts and User Interactions Log USB port for transferring Installer Setup, Customizable Reminders, Custom Events and Holidays to multiple thermostats. 3 assignable outputs to control humidification, dehumidification, ventilation and a stage of heating or cooling. 2 assignable inputs can be used with wired
Price 557.98 657.18 821.46
Description Prestige 2.0 HD Comfort System Kit Prestige 2.0 HD Comfort System Kit Prestige 2.0 HD Comfort System Kit
Includes THX9421R5013 Thermostat, THM5421R1013 Equipment Interface Module and two C7735A1000 Duct Sensors THX9321R5030 Prestige 2.0 Thermostat and C7089R1013 Wireless Outdoor Air Sensor THX9421R5013 Prestige IAQ 2-Wire Thermostat, THM5421R1013 Equipment Interface Module, REM5000R1001 Portable Comfort Control, C7089R1013 Wireless Outdoor Air Sensor and two C7735A1000 Duct Sensors
Simple and logical installer menu setup, programming and operation is enhanced by audio prompting that confirms touchscreen entries. Features like variable touchscreen security to prevent tampering, temporary and vacation overrides, and filter change reminders add convenience.
Programming: Universal choice of 7 day, 5/1/1 day programmable or non-programmable Display: 12-square-inch Approvals: Meets ENERGY STAR specifications Meets California Building Code, Title 24 Permanent program retention during power loss Furnace filter, humidifier pad change reminder Dimensions: 4.6"H x 5.9"W x 1.2"D
Application Gas, Oil, Electric, mV Gas, Oil, Electric, Dual Fuel, mV Gas, Oil, Electric, Heat Pump, mV, 3-Wire Zone Gas, Oil, Electric, Heat Pump, mV, Humidity Control Price 290.88 324.90 385.48 353.18
Stages Part No. 1F971277 1F951277 1F951280 1F951291 Heat 1 3 4 4 Cool 1 2 2 2 Program Universal Universal Universal Universal Power Battery or Hardwire Battery or Hardwire Battery or Hardwire Battery or Hardwire
80 SERIES BLUE
Stages Part No. 1F80 0471 1F850422 Heat 1 2 Cool 1 2 Program 5+1+1, 5+2, None 5+1+1, 5+2, None Power Battery or Hardwire Battery or Hardwire Application Gas, Oil, Electric, mV Gas, Oil, Electric, mV Price 121.68 152.94
Fossil fuel or electric heat compatible. 60% larger LCD with backlight. Permanent program retention during power loss.
Energy Management Recovery Meets ENERGY STAR specifications Configurable to non-programmable Fits vertical or horizontal junction box.
907
THERMOSTAT
DIGITAL, PROGRAMMABLE
BLUE 2"
2-square-inch Blue display with easy-to-see characters Exclusive Cool Savings feature saves energy during peak A/C demand periods Lighted display for easier low-light viewing Easy-to-wire push-connect color coded terminals 4 time and 4 temperature settings per program (heat and cool) Energy savings up to 33% Patented pre-programmed software simplifies time and temperature programming
Stages Part No. 1F800224 1F800261 1F820261 Heat 1 1 2 Cool 1 1 1 Program 24 Hour 5+1+1 5+1+1 Power Battery or Hard-wired Battery or Hard-wired
Temporary temperature override two-hour minimum or until next program period Selectable energy management recovery Dimensions: 4.8" W x 3.8" H x 1.5" D 0 to 30 VAC, 50/60 Hz or DC 0.05 to 1.5 Amps (load per terminal) 1.5 Amps maximum load (all terminals combined) Temperature Range: 45 to 90F Rated differential: 0.6 to 1.7F with adjustable anticipation Long battery life: uses 2 AA alkaline batteries (included) Exclusive battery power monitor 5-year warranty
Switching Application Electrica, Gas, Oil, mV Electrica, Gas, Oil, mV System H/O/C H/O/C/A H/O/C Fan A/O A/O A/O Terminals R,C,Y,W,G,O/B R,C,Y,W,G,O/B R,C,Y,W2,G,O/B,L Price 83.70 108.62 97.90
6-square-inch Blue display with easy-to-read without glasses characters Blue lighted display for easier lowlight viewing Large one-button one function keys for easy operation 2 time and 2 temeprature settings per program (1 setback) heat and cool, or selectable 4 time and 4 temperature settings (2 setbacks) Energy savings up to 33% Meets ENERGY STAR specifications Patented pre-programmed schedule simplifies time and temperature programming
Stages Part No. 1F95EZ0671 Heat 4 Cool 2 Program Non-Programmable or 5+1+1 or 7
Temporary temperature override two-hour minimum or until next program period Selectable energy management recovery Dimensions: 6.4" W x 4.2" H x 1.7" D 0 to 30 VAC, 50/60 Hz or DC 1.5 Amps (load per terminal) 2.5 Amps maximum load (all terminals combined) Temperature Range: 45 to 99F Rated differential: 0.6 to 1.2F with adjustable anticipation Choice of battery-powered with optional power stealing assist or hardwired with battery backup
Price 201.38
888-578-9100
Call our customer service center today and get the answers to all your HVAC/R related questions/needs: Provides technical assistance Helps you select the right product for your specific application Provides quotes and product availability Handles order requests Helps you locate the branch nearest you
908
THERMOSTAT
BLUE EASY INSTALL
Humidification and dehumidification control Intuitive menu-driven setup, programming and operation, with 1F98EZ1621 audio prompt Permanent program retention during power loss Indefinite setpoint hold or temporary temperature override Auto heat/cool changeover option automatically switches between heating and cooling programs Heating and cooling, heating only or cooling only configuration Setpoint temperature limits Maintains room temperature to within 1F Room temperature display can be recalibrated up to 5F
1F98EZ1621 features: Wireless comfort interface, equipment control and return air sensor 6" display Choice of 4 or 2 program periods per day Reduces hot and cold spots add up to 4 wireless sensors (3 indoor and 1 outdoor) Choice of dual fuel control with wireless temperature sensor or by Logic Program in Comfort Interface 1F98EZ1441 features: Universal 4-wire thermostat solution with outdoor remote sensor 12" trouchscreen display Upgrade single stage applications to premium high-efficiency systems, using existing 4 wires 4 time and 4 temperature settings per program (2 setbacks) heat and cool Dual fuel heat pump control
Program Method Battery Hardwire Application Electric, Gas, Oil, Heat Pump Electric, Gas, Oil, Heat Pump Price 429.66 459.30 Price 134.70
Stages Part No. 1F98EZ1621 1F98EZ1441 Part No. F145RF1600 Description Wireless Thermostat System, 6" display Universal 4-Wire Thermostat 12" Touchscreen Display Heat 4 HP ,2 Conventional 4 HP ,2 Conventional Cool 2 2 Non-Programmable or 7 Non-Programmable or 7 Description Wireless Remote Sensor for 1F98EZ1621, 4 1/2" x 3 1/4" x 1 1/2"
HEAT/COOL, 80 SERIES
REMOTE SENSOR
Fossil fuel or electric heat compatible. Large LCD display with backlight. Permanent program retention during power loss Configuration menu allows keypad selection of options Selectable C or F temperature display Selectable energy management recovery Classic White color
Stages Part No. 1F82261 Heat 2 Cool 1 Program 5+1+1 Power Method Hardwire Application Heat Pump Price 120.18
Digital output provides superior temperature control No temperature variance caused by wire resistance F1451328 Maximum wire distance: 300' Operating range: Indoor: 40 to 99F Outdoor:-40 to 140F Dimensions: 2 1/8"W x 3 1/2"L x 3/4"D
Part No. F1451328 F1451378 Description Indoor Sensor, Series 90 Outdoor Sensor, 12' Lead, Series 90 Price 52.66 61.08
1 Heat/1 Cool. Battery powered for maximum compatibility Fossil fuel or electric heat compatible Large LCD with backlight Selectable C or F temperature display Includes O and B terminals Classic White color
Part No. 1F78151 1E78151 Description Economy, 5+2 Program, Horizontal Economy, 5+2 Program, Vertical Price 62.78 62.82
Larger LCD displays setpoint temperature continuously and alternately shows actual time and temperature Hold temperature button allows manual program override for an indefinite period without changing programming on setback models For heating, cooling, electric heat, 1-stage heat pump Temperature range: 45 to 90F System switch: H/O/C, A/O Voltage: millivolt to 30 Vac
Part No. 1F80361 Description 5+1+1 Day Program, 4 Changes (2 Programs) Price 108.18
909
THERMOSTAT
ZONE CONTROL
WIRELESS THERMOSTAT KIT
Everything you need to relocate thermostat or upgrade equipment without running new wires.
YTH5320R1000
Powered by RedLINK reliability No interference with other wireless devices in the home Choose from programmable or non-programmable kits
Part No. YTH6320R1001 YTH5320R1000
Each kit includes: Wireless FocusPRO thermostat Equipment interface module Return air sensor YTH6320R1015 and YTH5320R1017 also include: Personal comfort station Wireless outdoor sensor Application: gas, oil, electric, heat pump, forced warm air, hot water, steam or gravity
Price 463.28 430.32
Includes TH6320R1004 Wireless FocusPRO 5-1-1 Programmable Thermostat; THM5320R1000 Equipment Interface Module; C7735A1000 Return Air Sensor TH5320R1002 Wireless FocusPRO Non-Programmable Thermostat; THM5320R1000 Equipment Interface Module; C7735A1000 Return Air Sensor
YTH6320R1023
Wireless Zoning Adapter Kit allows you to easily add to a TrueZONE system without running new wires.
Powered by RedLINK reliability No interference with other wireless devices in the home Choose from programmable or non-programmable kits
Each kit includes: Wireless Adapter Allows for wireless zoning when used with HZ432 or HZ322 TrueZONE panels (sold separately). Adapter receives communication from all wireless devices. Wireless FocusPRO Thermostat Same great features of the FocusPRO thermostats - now wireless Installs in minutes Displays outdoor temperature and humidity (outdoor sensor sold separately)
Price 342.70 308.38 106.42
Includes TH6320R1004 Wireless FocusPRO 5-1-1 Programmable Thermostat, THM4000R1000 Wireless Adapter TH5320R1002 Wireless FocusPRO Non-Programmable Thermostat, THM4000R1000 Wireless Adapter Description Wireless Adapter allows you to easily add RedLINK enabled thermostats to a TrueZONEsystem without running new wires.
HZ322
Universal Application; controls 3 zones Robust push terminals Common-sense LEDs Clean, professional installation
Smaller footprint Variable-speed fan control Can be used with W8665E wireless receiver
Additional features for HZ432 and HZ322 Discharge air temperature staging Intutive installer setup. Easy-to-follow, digital display uses real language to guide installer through four easy steps. Standardized checkout procedure...insures all installers check the same way and all zones function correctly before the installer leaves In addition the HZ432 offers dual fuel changeover based on outdoor temperature and/or thermostat staging, controls one extra zone and is expandable to 32 zones using TAZ4 Kits (HZ311K) include transformer and C7735A discharge air temperature sensor.
Stages 4H/2C 4H/2C 2H/2C 2H/2C 1H/1C 1H/1C Zones 4 4 3 3 3 3 Price 653.90 696.14 352.10 401.02 248.68 310.14
Application Conventional, Heat Pump, Dual Fuel Panel Conventional, Heat Pump, Dual Fuel Kit Conventional, Heat Pump Panel Conventional, Heat Pump Kit Conventional Panel Conventional Kit
910
THERMOSTAT
WIRELESS THERMOSTAT KIT
Wireless FocusPRO Thermostat: same great features of the FocusPRO thermostat - now wireless. Can display outdoor temperature and humidity. Dual Fuel enabled -requires C7089R1013 wireless outdoor sensor (sold separately).
Part No. YTL9160AR1000 TLM1110R1000
Equipment Interface Module (EIM): All HVAC equipment is wired to the module. Module receives communication from the wireless devices. Return Air Sensor: Works with the Equipment Interface Module to maintain safe indoor temperatures if power is lost at the wireless thermostat. Maintains 62 F for heating and 82 F for cooling. RedLink wireless technology
Price 326.84 193.14
Includes Wireless EConnect 7-Day / 5-2 Programmable Thermostat and Electrical Heat Equipment Interface Module Equipment Interface Module only
Panels allow additional zones to be added to central contol systems. Use TAZ4 with HZ432 panel to add another 4 zones (up to 32 zones maximum).
No. Zones 4
Price 383.96
Description VisionPRO IAQ Thermostat/Interface VisionPRO IAQ Thermostat/Interface/Outdoor Sensor VisionPRO IAQ Thermostat only VisionPRO IAQ Interface only
The TH9421C touch screen universal programmable thermostat provides electronic control of 24V/750mV heating and cooling systems in addition to humidification dehumidification and ventilation. Has all the features of the VisionPRO series except armchair programming Thermostat requires Equipment Interface Module (included in YTH package) or EnviraZone panel to control temperature, humidification, dehumidification and ventilation from a single point in the home. Compatible with all W8635, W8735, W8835 modules Includes humidification control with or without frost protection, dehumidification using whole house dehumidifier or air conditioning with high or low speed fan, advanced patented ventilation control and advanced dual fuel heat pump control.
The W8735D Telephone Access Module provides remote telephone access to the HVAC system when used with an EnviraCOM enabled thermostat such as the TH9421C1004 VisionPRO IAQ Total Home Comfort System, and the TH5320C1002 FocusPRO and T8635L1013 thermostat and the appropriate interface modules. The user can dial into the module and hear local temperatures and system settings. The user defines the temperature and humidity limits and their alert priorities to best meet their monitoring needs. Reports alert messages on high or low indoor/outdoor temperature, high or low humidity, low battery, auxiliary input sensor tripped, pass code change, air filter change required, system alerts, and power outage Supports 18 zones (W8735D1009) ; 36 zones (W8735D1017) when using zone panels
Part No. W8735D1009 W8735D1017 Description Phone Access Module, 2 Channel Phone Access Module, 4 Channel Price 716.36 1057.46
DISCHARGE SENSOR
A duct-mounted temperature probe used to provide capacity control of heating and cooling equipment. Used only with Honeywell C7835A1009 networked zoning, TZ, EMM, MABS Mounts in the supply air duct to sense the delivered air temperature
911
THERMOSTAT
DIGITAL, PROGRAMMABLE, COMMERCIAL
COMMERCIAL VISIONPRO
The TB8220 Commercial VisionPRO 8000 touchscreen programmable thermostat is an effortless, seven day programmable thermostat that provides universal system compatibility, precise comfort control and is easy to-program. The TB8220 provides temperature control for gas, oil, electric and heat pumps for up to 2 heat, 2 cool systems. Economizer output
Part No. TB8220U1003 Application Gas, Oil, Electric, Heat Pump
Commercial control algorithm Temporary and holiday overrides Title 24 compliant Multiple screen lockout levels Custom recovery ramps TB8220 and TB7220 can be used with C7089U1006 outdoor sensor and C7189U1005 indoor sensor (10K NTC) and select other 20K NTC commercial indoor sensors
Switching System H/O/C/A Fan A/O Price 416.72
TB7100 MULTIPRO
The MultiPRO multispeed and multipurpose thermostat is an effortless, 7-day programmable or nonprogrammable thermostat that provides universal system conpatibility, precise comfort and is easy to program. It provides temperature control for gas, oil, electric, heat pumps, PTACs, and fan-coil equipment for the following types of applications: 1H/1C conventional; Up to 2H/1C heat
Part No. TB7100A1000 Application Gas, Oil, Electric, Heat Pump, PTAC
pump; 4 pipe fan coil (3 fan speeds); 2 pipe fan coil (3 fan speeds); 2 pipe fan coil w/Auxilliary Heat (3 fan speeds); PTAC (Hi, Lo fan speeds). Large and clear display Real-time clock Speedy same schedule armchair programming Remote setback input for occupancy sensors or timeclocks Remote indoor air sensing option
Stages Display 4 sq. in. Heat 2 Cool 1 Switching System Fan H/O/C/A A/O, H/M/L
Price 265.10
TB7220 COMMERCIALPRO
This thermostat is an effortless, 7-day programmable thermostat that provides universal system compatibility, precise comfort control and is easy-to-program. The TB7220 provides temperature control for gas, oil, electric and heat pumps for up to 2 heat, 2 cool systems. Large, clear display with backlight shows the current and set temperature and time.even in the dark. Menu-driven programming make setup effortless. Beautiful ergonomic design is smart and sophisticated to match your customers lifestyle.
Part No. TB7220U1012 Application Gas, Electric, Heat Pump Power Method Battery and Hardwire
Real-time clock keeps time during power failures and automatically updates to daylight savings. Saving changes notification lets you know when the schedule changes have been saved. Change reminders let you know when to replace the batteries. Holiday override options allow you to override the program schedule, as desired. Speedy same-schedule programming.no need to copy multiple days. Armchair programming allows you to remove the thermostat from the wall for programming.
Stages Heat Cool 2 2 Switching System Fan H/O/C/A A/O
Price 328.76
T7047C and G sensors are used with T7300 for remote temperature sensing or averaging. Total at TT terminal on Q7300 should be 1420 or @ 75F. Taupe finish
912
THERMOSTAT
REMOTE SENSOR/OVERRIDE, T7300 SERIES
For use with T7300/Q7300 thermostat/sub base systems to provide space temperature sensing and switch initiation and indication of override from remote location
Finish Taupe
Price 283.06
HEAT/COOL
The T7350 commercial programmable thermostat controls 24 Vac commercial single zone heating, ventilating, and airconditioning (HVAC) equipment. It T7350B1002 consists of a thermostat and subbase. The thermostat includes the keypad and display for 7-day programming. The subbase includes equipment control connections. The subbase mounts on the wall and the thermostat mounts to the subbase. For single zone rooftop units, split systems, heat pumps, or hot/chilled water systems Two Occupied and two Not Occupied periods per day Thermostat interface module (TIM) connections to thermostat from PDA for advanced configuration, programming, keypad lockout, etc. changes can be made with thermostat mounted Individual heat and cool setpoints available for Occupied and Not Occupied periods P+I+D control minimizes temperature fluctuations Recovery ramp control automatically optimizes equipment start times based on building load Intelligent Fan feature energizes fan continuously in the Occupied periods; fan can also be configured for conventional heat or electric heat fan operation.
Part No. T7350A1004 T7350B1002 T7350D1008 T7350M1008 T7350H1009 T7350H1017 T7351F2010 Maximum Stages Heat/Cool 1/1 +1 2/2 +1 3/3 or 2/4 2(420mA) + 2 3/3 2(420mA) + 2 3/3 or 2/4
Convenient overrides allow temporary setpoint changes Keypad multi-level lockout available with all models Remote sensor capability for temperature (including outdoor air and discharge air) and humidity sensors Auxiliary subbase contact typically interface with a Honeywell Economizer System (for total rooftop control integration) or act as dehumidification output Features Available via PDA Configuration * PDA not included 365 day clock with holiday programming Automatic Daylight Saving Time adjustments Selectable dehumidification limit control Occupancy input to control standby setpoint Additional standby period used in low traffic areas Sequential start option Discharge air high/low limits Selectable recovery ramp Ambient lockout (with outdoor sensor) Available in these market areas: Long Island, NY, West Chester County, NY, New York City, Phoenix, AZ
534.58
BLUETM
Pre-occupancy purge and/or programmable fan Remote sensing indoor or outdoor and at the thermostat Prioritizing or averaging between indoor sensor and thermostat Keypad limited or total lockout Limited temperature range
Stages Part No. 1F950680 Heat 4 Cool 2 Program 7, 5+1+1, None
For 24 VAC or Millivolt Systems Large, 6-square-inch display with backlight Exclusive Cool Savings feature saves energy during peak A/C demand periods Automatic daylight savings option Meets ENERGY STAR specifications
Price 308.30
Features Outdoor, Discharge Air Outdoor, Discharge Air, Humidity, Occupancy Outdoor, Discharge Air, Humidity, Occupancy Outdoor, Discharge Air, Humidity, Occupancy, LonWorks bus Outdoor, Discharge Air, Humidity, Occupancy, LonWorks bus
913
THERMOSTAT
DIGITAL, PROGRAMMABLE, COMMERCIAL
HEAT/COOL
Modulating and direct economizer outputs Discharge and outside air temperature inputs Fan failure and filter status indication Can be wired together to create a complete building automation and control network Programmable user functionality including occupied override, fan control, and system control, occupied setpoint limits and the duration of occupied override Adjustable delay on powerup for soft starts
Part No. SZ1022 SZ1024 SZ1017 Usage Conventional Heat Pump Modulating Heat or Cool Stages 2 Heat, 2 Cool, +1 2 Comp., 2 Aux. 2 Heat or 2 Cool 2 Heat or 2 Cool 2 Heat or 2 Cool 2 Heat, 2 Cool, +1 2 Heat, 2 Cool + 1 2 Heat, 2 Cool
P + I control option Monitor occupied override, heat stages 1 and 2, cool stages 1 and 2, a third stage, fan interlock, cool lockout, filter status, outdoor air temperature, discharge air temperature at the stat, from a local computer, or from any PC equipped with a modem Smart recovery User setpoint adjustment limits Local and remote override capability Auxiliary time clock output (economizers) External time clock input option Superstat
Program Day 7 Day 7 Day 7 Day 365 365 365 365 365 Day Day Day Day Day Remote Sensing Discharge Discharge Discharge2, Outdoor Discharge, Outdoor Discharge2, Outdoor Discharge, Outdoor Discharge, Outdoor Discharge, Outdoor Price 712.98 674.76 658.36 1019.32 1019.32 1014.54 942.76 919.50
Modulating Heat or Cool SZ10511 Modulating Heat and Cool SZ1053 Conventional SZ1031 Heat Pump SZ1033 Conventional SZ10411 1 Modulating economizer control 2With reset
WSK-24 automatically controls HVAC equipment by determining when a room is occupied. It uses the combination of an occupancy sensor and a door switch to provide optimal control. Wireless system provides quick and easy installation Pre-configured door sensor and occupancy sensor Fuse protection Long battery life Low battery indication Receiver memory retained after power loss Includes 24V dry contact receiver Wireless PIR (passive infrared receiver) occupancy sensor with mounting kit Wireless door sensor with mounting kit Wiring harness. The receiver can be wired into any thermostat or controller that supports the connection of a remote setback device. The receiver communicates wirelessly to a PIR occupancy sensor, a door sensor, and an optional 2nd door/window sensor.
Part No. WSK24 Use With TB8575, TB7100, T7351, T7350 Price 287.66
Direct wired wall modules for use with the Honeywell T7350 thermostats.
Push button setpoint adjustment with LED indicators. Occupied/unoccupied override with LED. LONWORKS bus jack. Operating range 45 to 99F Dimensions: 5 1/32"H x 3 5/32"W x 1"D
Part No. T7771A1005 Description 20 K Ohm Non-Linear Temperature Wall Module Price 175.88
More than 50,000 items in stock and available for immediate shipment.
914
THERMOSTAT
FAN COIL
NEPRA SERIES
Specifications: Range: 60F to 85F Accuracy: 1F Comfort limits: 60F to 85F Economy limits: Cool 78F to 88F, Heat 55F to 68F Temperature setting and fan selection: push button Case: flame retardant, high impact plastic, white or tan Cycle rate: Default 8 cycle/hr. (field programmable 1 to 24 - disabled when set to 0) For highly corrosive environments such as high humidity, salty air, dusty air, etc., it is highly recommended that controls be ordered with conformal coating (add a "K" after "NP" in the part number; at the end of the"PFC" part numbers).
ELECTRONIC, NEPRA 4000 SERIES
ACCESSORIES
Part No. SB1 PSB PAK PRS KF 1 Description Subbase for Nepra 4000/4500, No Instructions Mounting Place for Nepra Premier Remote Sensing Aquastat Kit for Nepra Premier Wall Mount Remote Sensor for Nepra Premier Configuration Key Fob for Nepra 4000/4500 Price 15.50 15.50 72.61 64.00 57.01
ELECTRONIC
Designed for 2 pipe and 4 pipe fan coil systems with two fan speeds. These controls are equipped with flexible options that allow the installer to set a variety of features, such as comfort limits, cycle rate, etc. Dimensions: 3.5"W x 5"H x 1.5"D ETL listed
Part No. NP4024U NP4120U NP4240U NP4277U Voltage 24 Vac 120 Vac 240 Vac 277 Vac Fan Switching H/L/Auto H/L/Auto H/L/Auto H/L/Auto Fan Control User Selectable User Selectable User Selectable User Selectable Price 154.00 154.00 154.00 154.00
For stand-alone digital control of fan coil units, heat pumps and terminal units. The microprocessor based units combine a proportional plus integral (P+I) control algorithm with advanced adaptive logic. This provides precise and stable control under varying system capacity and load conditions. Line voltage continuous or line voltage 3-speed fan control Remote setback capability from a time clock or facility management system
ELECTRONIC, T158 SERIES
TB158001 Part No. TB158001 TB1582 Description Heat/Cool Heat/Cool Fan Switching None O/H/M/L Price 223.44 241.08
FAN COIL
Part No. PFCA24 PFCM24 PFCALV PFCMLV PFCA24RS PFCM24RS PFCALVRS PFCMLVRS
Comments Remote Sensing, Setback Remote Sensing, Setback Remote Sensing, Setback Remote Sensing, Setback
Price 176.00 176.00 186.00 186.00 198.00 198.00 Part No. T4039M1004 Application Auto Heating /Cooling T4039M1004
Controls line voltage fan coil valves in cooling, manual, or automatic changeover heating-cooling systems.
210.00
Please contact your local United Refrigeration Branch or our Customer Service Center for pricing.
CONTROLS & ELECTRICAL ACCESSORIES
Universal heating and cooling digital thermostats designed for 2 pipe and 4 pipe fan coil systems with 1, 2, or 3 fan speeds. They are available in both auto- and manual-changeover models, and the user can select the fan control - user-selectable, auto, or constant. Flexible options allow the installer (or property owner) the ability to set a variety of features, such as comfort limits, economy limits, cycle rate, etc. They also have a sleek, rounded look that fits into any dcor. ETL Approved
TA168002 Part No. TA168001 TA168002 TA168004 Description Fan Switching Dual Output, Heat/Cool, Aux Heat None Dual Output, Heat/Cool, Aux Heat O/H/M/L Single Output, Heat/Cool None Price 231.84 288.96 225.96
915
THERMOSTAT
FAN COIL
FAN COIL SUB BASE, T6051, T6052
The TB6575A, TB6575B, and TB8575A SuitePRO Digital Fan-Coil Thermostats can be used for residential and commercial applications. They are great for use in hotels, condos, and school classrooms. Dimensions, Approximate: 3 3/4"H x 5 1/2"W x 1 1/2"D Electrical Ratings: 120 Vac, Fan Rating: 6.0 A, Relay Rating: 1.0 A; 240 Vac, Fan Rating: 3.0 A, Relay Rating: 1.0 A Digital display of ambient temperature, setpoint, mode icons when cooling or heating relays operate, when energy savings mode is active, and fan status. Optional freeze protection feature that turns on heat, if necessary. Energy savings mode -- external energy savings input from dry contact such as time switch, occupancy sensor, or hotel cardkey overrides comfort setpoint with selectable setback heating or cooling setpoints. Energy savings input configurable as a normally open or normally closed dry contact. Proportional plus integral (P+I) control algorithm for precision temperature regulation. Selectable C or F. Adjustable deadband, in auto changeover mode, for heat and cool control. Adjustable maximum heating and minimum cooling setpoint limits. Installer setup mode allows changes of operating parameters. EEPROM permanently retains user settings, including setpoints, during power loss (no batteries required). Capability to display temperature sensor failure for easier troubleshooting. Optional remote temperature sensor and remote pipe sensors (20K). Switch positions: System: O/H/C/A Fan: H/M/L/A/O
CONTROLS & ELECTRICAL ACCESSORIES
Part No. TB6575A1000 TB6575B1000 TB6575C1000 TB8575A1000 Application 2 or 4 Pipe, Heat/Cool/Auto 2 Pipe, Heat/Cool 2 or 4 Pipe, Heat/Cool/Auto 2 or 4 Pipe, Heat/Cool/Auto Voltage 120/240 120/240 120/240/277 24 Price 168.02 161.10 170.40 156.48
Provides manual system switching for T6051 thermostats. Includes pressure sensitive labels to identify switching positions
Position Labels Part No. Q651A1009 Supplied Heat/Off/Cool Auto/Off/On Heat/Off/Fan Use With T6051A Price 113.16
Controls line voltage valves, motors, contactors, electric heat elements, duct furnaces, and fan coil units in heating/cooling systems. Contact rating: 4 F.L. Amp @ 277 Vac Fixed differential: 2F
Temperature Part No. T651A3018 Application Heat/Cool Switch SPDT Range (F) 44 to 86 Price 117.98
Provides direct line voltage control of fan coils, fans, motor starters, circulator motors, contactors, valves for heating, cooling or SPDT applications.
Range (F) 36 to 90 Differential (F) 1.5, Fixed FL Amp (@ 240 Vac) 4
Switch SPDT
Price 113.06
Used to control line voltage fan coils, fans, motor starters, valves, contactors, and circulator motors in heating and/or cooling systems. Contact rating: 8 F.L. Amp @ 240 Vac
T6052A1015 Temperature Range (F) 50 to 80 46 to 84 46 to 84 46 to 84 Differential (F) 1, Fixed 1, Fixed 1H-2C, 2.5F , 2H-1C, 3.2F 1H, 2.5F , 2C, 3.2F
916
THERMOSTAT
LINE VOLTAGE
LINEVOLTPRO THERMOSTATS 7 DAY PROGRAMMABLE
Applications include Electric Baseboards, convectors, radiant heat and fan-forced heaters. Electric Heat Heating indicator gives confirmation that heat is on. Maintenance free and no batteries are required. Quiet Operation: Epoxy-soundproofed relays On/Off Switch. 1F Control Backlit Display Voltage: 208-240 Vac
LINEVOLTPRO 7000, NON-PROGRAMMABLE
Can be used to control 2-way zone valves, 3-way zone valves or circulator pumps in both line volt and low volt applications. It also offers special protection modes to prevent system seizures and to reduce callbacks. Easy to install, provides cost-efficient programmable control of hydronic heating systems. Application Baseboards Convectors Fan-forced heaters Radiant ceilings Central heating (Conventional)
Part No. TL8100A1008 Application Heat Only Contact Rating (Amps) 5 (Resistive), 2 (Inductive) @ 240 VAC Price 108.74
Switch DPST
Price 94.36
Switch DPST
Price 109.64
MEDIUM DUTY
Controls line voltage valves, motors, contractors, electric heat, elements, duct furnaces, and fan coil units in heating/cooling systems. Automatic cooling and heating anticipation Mounts on standard vertical or horizontal outlet box
Part No. T451A3005 Temperature Range (F) 4486 Switch SPST, Open Rise Price 114.58
ELECTROMECHANICAL
T498A1778
Provides line voltage control of electric heating systems. Long lasting Micro-Switch mechanism Thermometer included Contact rating: 22A resistive @ 240 Vac
Temperature Range (F) 4080 4080 4080
Switch SPST, Open Rise DPST, Open Rise DPST, Open Rise
The Radiant series thermostats are simple to use and feature a large easyto-read display. Both programmable and nonprogrammable models offer adjustable temperature limiting, which allows the installer to program setpoint limits and makes them ideal for property management applications such as apartments, condos, and student housing. These controls work with baseboard electric heat, radiant heat zone valves, infrared heaters, exhaust fans, and line voltage air conditioning. Specifications: Case: flame retardant, hi-impact plastic, white Dimensions: 3.1"W x 5.0"H x 1.5"D Display: LCD, 1.4" x 0.5" Range: 40F to 85F (5C to 30C) Accuracy: 1.0F (0.5C) Temperature Setting: Push Button Load Rating: 16 amps Voltage: 120 VAC or 208/240 VAC ETL Approved
917
THERMOSTAT
GENERAL PURPOSE, LINE VOLTAGE
RADIANT SERIES, DIGITAL, PROGRAMMABLE LOCKED CASE
The Radiant thermostat provide highly efficient temperature control while saving energy with a flexible programming schedule. They feature 5-1-1 programming, which allows for up to four events per day and separate programming for each weekend day. A non-volatile memory chip protects the programming in the event of a power loss.
Part No. RPLV120S RPLV240S RPLV240D RPLV120SC RPLV240SC RPLV240DC Application Heat Only Heat Only Heat Only Cool Only Cool Only Cool Only Voltage 120 208/240 208/240 120 208/240 208/240 Switch SPST SPST DPST SPST SPST DPST Price 154.00 154.00 158.00 154.00 154.00 158.00
For installations where heavy duty thermostats with tamperproof features are required. Ideal for control of infrared heater installations. "Limited maximum setting": internally adjustable stop prevents movement above desired setting.
Range Part No. 1766 (F) 40 to 80 Differential (F) 3, Fixed Switch SPST, Open Rise F.L. Amps (@ 240 Vac) 7.0 Price 284.40
HEAT/COOL
For equipment requiring a closed circuit on both rise and fall of temperature.
Range (F) 55 to 95 Differential (F) 3, Fixed F.L. Amps (@ 240 Vac) 3.7
HEAVY DUTY
Electric heat thermostats used for controlling baseboards, cable heat, glass panels, etc. Resistive 22 Amp @ 240 Vac, 5,000W
1A65641 Range (F) 40 to 85 40 to 85 Differential (F) 1, Fixed 1, Fixed
Switch SPDT
Price 255.18
PROPORTIONAL
T921 SERIES
Provides low voltage, 3-wire control for valve motors, damper motors, and balancing relays in heating or cooling system applications. Operating range: 5684F
Fixed Throttle Part No. T921A1191 Range (F) 2.5 Application Heat or Cool Price 482.80
HEAT/COOL
For line voltage control of residential, commercial, or industrial heating or year round air conditioning. Liquid charged temperature sensing element and highly efficient diaphragm and leverage provides close temperature control. Temperature range is 40 to 90F.
Part No. T26S18 Switching SPDT, Heating & Cooling Price 147.24
For accurate control of line voltage devices such as air conditioners, unit coolers, display cases and walk-in boxes. Contact rating: 8.0 F.L. Amp @ 240 Vac
Range (F) 55 to 95 Differential (F) 2, Fixed
The ZonePRO thermostats are for low voltage pressure dependent VAV applications. Can also be used for hydronic perimeter heating/cooling and bypass box with or without reheat. Provides min/max setpoints for heating and cooling Provides night setback terminal for energy savings
Part No. TB6980A1007 TB6980B1006 TB7980A1006 Output Type Floating, 0.5 A Floating, 0.5 A 0-10 Vdc or 2-10 Vdc 010V, 10k min Modulating (0-10 Vdc) control Comments Plus 1 Analog/TRIAC, 1 TRIAC outputs Plus 1 Analog/TRIAC, 1 TRIAC Output Price 202.76 253.36 226.32
Price 274.74
HEATING
292.00
Differential (F) 2, Fixed 2, Fixed Switch SPST, Open Rise SPST, Open Rise Price 249.92 249.92
(F) 55 to 85 55 to 95
918
THERMOSTAT
GUARD
Metal Thermostat Guards: Metal Thermostat Guards: Constructed of 18-2 gauge steel and are finished with a durable baked enamel. Plastic Thermostat Guards: Constructed of hi-impact plastic, and are designed for use in offices, restaurants, or other businesses where lightweight, medium protection is required to avoid tampering. Ring base is for installation over existing thermostats. Solid base is for new installations (added strength). All models furnished with locking key and mounting hardware. Thermostat guards can be installed in a vertical or horizontal position.
Clear plastic
Opaque plastic
Metal
"U" SERIES
Specifications: Solid Base: 8 1/4"H x 5 3/8"W x 3 1/2"D Ring Base: 8 1/8"H x 4 5/8"W x 3 5/8"D
Specifications: Solid Base: 6 1/4"H x 4 3/4"W x 3"D Ring Base: 6"H x 3 3/16"W x 3 1/8"D
Part No. BTG54VL Description Metal Hinged Guard with Solid Base Price 26.64
Description Clear Plastic Guard with Solid and Ringed Bases Metal Guard and Solid Base Metal Guard and Ring Base
"K" SERIES
Specifications: Solid Base: 6 1/4"H x 4 3/4"W x 3"D Ring Base: 6"H x 3 3/16"W x 3 1/8"D
Part No. BTG54VLW Description Metal Hinged Guard with Ring Base Price 26.64
Specifications: Solid Base: 5 1/4"H x 4 5/8"W x 3"D Ring Base: 5 1/4"H x 4 5/8"W x 3 1/4"D
"E" SERIES
Price 21.58 25.20 34.70
Description Clear Plastic Guard with Solid & Ringed Bases Opaque Plastic Guard with Solid & Ring Bases Metal Guard with Ring Base
"R" SERIES
Specifications: Solid Base: 7 1/4"H x 5 3/8"W x 3 1/2"D Ring Base: 6 3/4"H x 4 1/4"W x 3 9/16"D
REPLACEMENT KEY
Description Clear Plastic Guard with Solid & Ringed Bases Metal Guard with Solid Base Metal Guard with Ring Base
Price 21.76 37.26 33.14 Part No. F336 Description Universal Key Price 2.76
UNIVERSAL
Encloses and protects wall thermostats against tampering, damage and unauthorized adjustment of thermostat settings. Includes opaque polystyrene wallplate, ring base, guard cover, tumbler lock, two keys and optional Honeywell logo insert
TG510A1001 Part No. TG510A1001 TG511A1000 TG511D1004 TG512A1009 TG512D1003 L (In.) 5 7/8 6 1/2 6 3/8 7 1/4 7 1/8 W 5 7 7 9 9 (In.) 7/8 1/2 3/8 3/4 5/8 D (In.) 2 1/2 2 15/16 2 7/8 3 3/8 3 1/4 Cover Style Clear Clear Metal Clear Metal Use With T87, TP970, etc. T874, etc. T874, etc. T8600, T8090, etc. T8600, T8090, etc. Price 43.34 42.90 62.16 44.48 70.40
919
TEMPERATURE
REMOTE BULB
The A19 Series are single stage temperature controls that incorporate liquid filled sensing elements. Suitable for temperature control in heating, ventilating, and refrigeration.
WIDE RANGE, ADJUSTABLE DIFFERENTIAL
A19ABC24 Range (F) -30 to 100 -30 to 100 -30 to 100 -30 to 100 Differential (F) 3 to 12 3 to 12 3 to 12 3 to 12 Bulb (In.) 3/8 x 4 3/8 x 4 3/8 x 4 3/8 x 4 Capillary Length (Ft.) 6 8 10 20 Max. Bulb Temp. (F) 140 140 140 140 F.L. Amps (@ 240V) 8 8 8 8
FIXED DIFFERENTIAL
Range Part No. A19AAF12 Switch SPDT (F) 25 to 225 Differential (F) 3 1/2 Bulb (In.) 3/8 x 3 Capillary Length (Ft.) 10 Max. Bulb Temp. (F) 275 F.L. Amps (@ 240V) 3 Price 195.44
CLOSE DIFFERENTIAL
Part No. A19AAD51 A19AAF20 A19AAF21 1 Bulk Milk Cooler Switch SPST, Open Low SPDT SPDT Range (F) 30 to 50 -30 to +100 40 to 90 Differential (F) 2 1/2 2 1/2 1 1/2 Bulb (In.) 3/8 x 2 5/8 3/8 x 4 3/8 x 5 3/8 Capillary Length (Ft.) 6 6 6 Max. Bulb Temp. (F) 190 140 140 F.L. Amps (@ 240V) 3 3 3 Price 182.82 158.92 158.92
MANUAL RESET
Part No. Switch SPST, Open Low SPST, Open Low SPST, Open High Range (F) -30 to 100 -30 to 100 100 to 240 100 to 240 Differential (F) Manual Manual Manual Manual Bulb (In.) 3/8 x 4 3/8 x 4 3/8 x 3 1/2 3/8 x 3 1/2 Capillary Length (Ft.) 6 10 6 None Max. Bulb Temp. (F) 140 140 290 290 F.L. Amps (@ 240V) 8 8 6 6 Price 160.56 172.26 175.70 150.48
WIDE RANGE
Provides limit or temperature control in refrigerated areas where remote mounting of sensing element is required. Contact rating: 5.1 F.L. Amp @ 240 Vac
T6031A1029 Temperature Range (F) -30 to 90 40 to 180 15 to 90 -30 to 90 -30 to 90 40 to 180 30 to 270 55 to 90 Differential (F) 3.5 to 12 5, Fixed 3.5 to 16 3.5 to 16 3.5 to 16 2, Fixed 7, Fixed 1.5, Fixed Max. Temp. (F) 125 205 125 130 130 205 305 150 Capillary Length (Ft.) 8 5.5 5 8 20 5.5 5.5 5.5
Part No. T4031A1073 T4031C1012 T6031A1011 T6031A1029 T6031A1060 T6031C1009 T6031D1049 T6031E1004
Switch SPST, Close Rise SPST, Open Rise SPDT SPDT SPDT SPDT SPDT SPDT
920
TEMPERATURE
WIDE RANGE
Wide range temperature controls. Contact rating: 17 F.L. Amp @ 240 Vac
060101 Range (F) -35 to 95 -35 to 95 -20 to 70 95 to 240 Differential (F) 4 to 50 4 to 50 3.5 to 35 6 to 50 Capillary Length (Ft.) 8, Cross Ambient Air Coil 8, Cross Ambient 8, Cross Ambient
WIDE RANGE
Snap-action electrical contacts minimize Fingertip manual trip feature allows contact function testing without tools
060L5206 Range (F) -20 to 60 -20 to 60 25 to 95 -15 to 60 25 to 70 Differential (F) 2.5 to 40 2.5 to 40 3 to 45 5 to 50 4 to 18 Bulb (In.) 1/10 x 19 5/8 1 1/2 x 1 1/4 1 1/2 x 1 1/4 3/8 x 3 3/8 3/8 x 4 1/2 Capillary Length (In.) 80 None None 80 80 Max Bulb Temp. (F) 250 250 250 175 175 F.L. Amps (240V) 24 24 24 24 24
WIDE RANGE
Switch SPDT
Price 79.00
RUBBER BULB
Rubber coated bulb and capillary provide corrosion resistance Bulb designed for direct immersion
CONTROLS & ELECTRICAL ACCESSORIES
Switch SPDT
Range (F) 40 to 90
Price 200.92
RAINPROOF ENCLOSURE
921
TEMPERATURE
REMOTE BULB
REMOTE BULB, HEAVY DUTY
The A72AE and A72CE are wide range temperature controls with heavy duty DPST contacts and neoprene coated sensing elements for control of cooling tower fans, motorized valves, or solenoid operated valves. Heavy duty construction
A72AE1 Range (F) 24 to 90 24 to 90 Differential (F) 4 to 25 4 to 25 Bulb (In.) 3/8 x 6 3/4 3/8 x 6 3/4 Capillary Length (Ft.) 6 6 Max. Bulb Temp. (F) 170 170 F.L. Amps (@ 240V 1) 24 24
Temperature sensing applications requiring two-stage control of HVAC/refrigeration equipment. Wide temperature ranges
A28AA29 Range (F) -30 to 110 40 to 90 60 to 140 20 to 80 Differential (F) 5, Fixed 3, Fixed 5, Fixed 2, Fixed Interstage Differential (F) 2 to 7 2 to 7 2 to 7 2 to 7 Bulb (In.) 3/8 x 4 3/8 x 4 3/8 x 4 3/16 x 22 Capillary Length (Ft.) 8 6 6 6 Max. Bulb Temp. (F) 140 140 230 140 F.L. Amps (@ 240V) 8 8 8 3
The A28MA controls are wide range temperature controls with rainproof NEMA 3R enclosure and two SPDT switches.
Sump water temperature control for cooling towers and evaporative condensers Fan cycling control for air cooled condensers
The A36 Series are four stage thermostats with open construction for use in panel mounting. Cycling control for multiple refrigeration compressors or unloading type compressors Suggested replacements available under System 350 electronic temperature controls
A36AHA58 Range Part No. A36AHA52 A36AHA58 A36AHB33
1
(F) 55 to 95 0 to 70 0 to 70
WATER CHILLER
Remote bulb temperature control with limited setpoint range, adjustable differential, and adjustable cutout.
Range (F) 38 to 80
Differential (F) 8 to 40
Price 472.38
922
TEMPERATURE
A72AA SERIES
The A72 Series temperature controls incorporate a vapor charged sensing element and heavy duty contacts. Automatic control of heavy electrical loads DPST contact block contains two isolated sets of contacts that make or break simultaneously
REMOTE BULB
Differential (F) 3 to 30 3 to 30
(F) 15 to 55 50 to 90
Cross ambient.
COILED BULB
Coiled copper bulb Space sensing thermostat with heavy duty contacts for cooling applications
Differential (F) 3 to 30
BULB WELL
Brass and copper wells Maximum pressure: 300 psig Maximum temperature: 250F Monel wells Maximum pressure: 1,000 psig Maximum temperature: 700F
Dimensions (In.) Part No. WEL11A601R WEL14A601R WEL14A602R WEL14A603R WEL17A600R A 2 3/8 7 9/16 4 15/16 5 13/16 10 7/16 B 2 5/16 1 13/16 1 13/16 1 13/16 3/4 C .299 .430 .430 .430 .763
Construction Connector Brass Brass Brass Brass Malleable Tube Copper Copper Copper Copper Copper Price 66.16 61.78 58.86 59.48 182.88
BULB WELL
Copper wells Maximum pressure: 255 psi Maximum temperature: 300F Include mounting clamp
923
TEMPERATURE
REMOTE BULB
HEAT CONDUCTIVE COMPOUND
Price 21.90
T675A1508
T678A1478
Remote bulb thermostats regulate temperature of air or liquids in ducts, pipes, tanks and boilers. Fast response models operate approximately four times faster than standard models Standard bulb size: 1/2" x 4 3/16" 55175F bulb size: 1/2" x 3 9/16" Contact rating: 5.1 F.L. Amps @ 240 Vac
Interstage Differential (F) 3 to 10 3 to 10 1, Fixed 3.6 to 12 3 to 10 1, Fixed 1, Fixed 3 to 10 3.6 to 12 3 to 10 3 to 10 3.6 to 12 Manual Manual Differential (F) Capillary Length (Ft.) 20 20 20 20 5 5 20 5 5 20 5 5 10 20 Fast Response No No No No No No No No No No Yes Yes No No Price 513.34 226.62 208.28 220.94 199.82 192.72 214.14 210.82 205.50 229.12 217.32 223.02 219.22 238.94
CHANGEOVER
Senses supply water temperature in air conditioning equipment or outdoor temperature in ventilation systems. Bulb size: 3/8" x 3"
Switch 2-SPDT
Differential (F) 5
Price 199.70
924
TEMPERATURE
2 STAGE, SEQUENCED
Used for sequenced control of air temperature in two-stage heating or cooling systems or for single stage heatingcooling control. Bulb size: 5/16" x 11 11/16"
Switch 2-SPDT
Price 214.02
Positive control for refrigeration applications Switch: SPST, close rise Hydraulic action element
1609101 Range Part No. 160990 1609101 1609103 1609104 1609105 168791
1
Bulb Size (In.) 3/8 3/8 3/8 3/8 3/8 x x x x x 5 5 5 5 5 1/4 1/4 1/4 1/4 1/4
F.L. Amps (@ 240Vac) 3.7 8.0 8.0 8.0 8.0 3.7 Price 110.54 100.28 112.90 137.72 106.20 113.72
-30 to 90
3/8 x 5 1/4
SPDT
Control stops compressor when ice bank completely covers sensing element and starts compressor when ice bank begins to melt
Switch: SPST, close rise Nickel plated bulb for sanitary requirements Use as bin level control
Differential (F) 3 to 20
ICE BANK
Suitable for soft drink dispensers, drink vending machines, and ice builders for thermal storage. Uses a special water-filled bulb and transmission fluid to control ice thickness in applications utilizing a refrigerated water bath with ice bank reserve capacity.
CONTROLS & ELECTRICAL ACCESSORIES
Price 148.38
GENERAL PURPOSE
Senses air or coil temperature to provide regulation of any remotely controlled area.
Differential (F) 4 to 30
Price 189.12
925
TEMPERATURE
REMOTE BULB
GENERAL PURPOSE
These controls offer a wide selection for such products as self-contained refrigerators, freezers, coolers, walkin units, and refrigeration display cases.
0101409 Range Part No. 0101010 0101072 0101408 0101409 0101410 0101416 0101418 0101419 0101433 0101473 0101491 0101802 016104 016111 016601 0207041 (F) 0 to 55 -15 to 40 -15 to 40 0 to 55 25 to 75 0 to 55 0 to 55 -35 to 15 -35 to 15 0 to 55 25 to 75 25 to 75 0 to 55 0 to 55 22.5 to 47.5 0 to 100 Differential (F) 7 to 55 3 to 20 3 to 20 3 to 20 3 to 20 3 to 20 3 to 20 3 to 20 3 to 20 7 to 55 2, Fixed 3 to 20 3 to 20 3 to 20 1.5, Fixed 6 to 20
Contact rating: 24 F.L. Amp @ 240 Vac NEMA 1 enclosure Universal mounting
Capillary Switch SPST, Open Low SPST, Open Low SPST, Open Low SPST, Open Low SPST, Open Low SPST, Open Low SPST, Open Low SPST, Open Low SPST, Open Low SPST, Open Low SPST, Open Low SPST, Open Low SPDT SPDT SPDT DPST, Open Low Length (Ft.) 4 Air Coil 6, w/Bulb 6, w/Bulb 6, w/Bulb 6 Air Coil 6 6, w/Bulb 6, w/Bulb 6, w/Bulb Air Coil 6, w/Bulb 6 3, Cross Ambient Bulb 8, Cross Ambient Price 146.10 144.84 134.80 128.38 136.30 138.80 138.80 137.48 147.78 137.40 136.74 143.98 144.74 161.24 159.34 265.60
SPACE
UTILITY LINE VOLTAGE, HEAVY DUTY
A19BAC for ventilating and heating applications A19BBC2 for cooling applications Return air or space temperature sensing
A19BBC2 Range (F) 30 to 110 -30 to 100 Differential (F) 3 1/2, Fixed 3 to 12 Capillary Length (In.) 1 3/8 x 2 1/4 Coiled 1 3/8 x 2 1/4 Coiled Max. Bulb Temp. (F) 140 140 F.L. Amps (@ 240V) 8 8
EXPLOSION PROOF
Provides SPDT heavy-duty, line-voltage temperature control in ventilation, heating or cooling. Contact rating: 3.7 F.L. Amp @ 240 Vac Air coil element
Temperature Range (F) -30 to 100 Fixed Differential (F) 3.5
Hazardous location heating thermostat. For use in hazardous atmospheres (oil refineries, grain elevators, munitions plants, flour plants, hospital operating rooms). Switch: SPST, open rise Contact rating: 7.0 F.L. Amp @ 240Vac
Part No.
Switch SPDT
Price 166.20
2A202
Range (F) 40 to 90
Price 669.58
926
TEMPERATURE
EXPLOSION PROOF FARM-STAT
Designed for use in grain elevators, chemical and powder plants, mines, oil refineries. For use in Class I, Group D and Class II, Group E, F, and G hazardous locations. Coiled bulb sensing unit
T631A1022
Provides line voltage control of heating, cooling and ventilating systems in farm buildings or storage areas. Treated to resist corrosion Contact rating: 3.7 F.L. Amp @ 240 Vac
Temperature Fixed Differential (F) 2 2 3 2 3 2 5 Price 192.48 200.96 192.48 307.38 206.18 214.88 206.18
Switch SPDT SPDT SPDT 2-SPDT SPDT, 5.1A SPDT SPDT, 5.1A
NEMA 4X ENCLOSURE
The A19PRC is a single stage electromechanical thermostat designed for heating and ventilation applications. It features a raintight enclosure for use in agricultural and industrial applications that require compliance with Article 547 of the National Electric Code. The A19PRC has a rugged thermoplastic enclosure that meets NEMA 4X specifications. Coiled sensing bulb Exposed portion of the sensing element is plated and plastic coated to resist damage in corrosive atmospheres
Part No. A19PRC1 Switch SPDT Range (F) 30 to 110 Differential (F) 3 to 12 Price 352.22
FARM-STAT, NEMA 4X
Provides line voltage control of heating, cooling and ventilating systems in farm buildings, storage areas and industrial environments; watertight, dust-proof enclosure. Contact rating: 3.7 F.L. Amp @ 240 Vac
Temperature Part No. T631F1068 Switch SPDT Range (F) 35 to 100 Fixed Differential (F) 2 Price 372.82
Switch 2-SPDT
Price 276.20
How can URI help you achieve success? Huge Local Inventory Broad Product Scope Knowledgeable Staff
927
TEMPERATURE
DEFROST TERMINATION, FAN DELAY
Remote bulb control with adjustable defrost termination temperature and preset fan delay temperature. Defrost termination control for refrigerated display cases Sensing element unaffected by barometric pressure and cross ambient temperature problems
Switch SPDT
Price 428.42
F25 SERIES
The F25 control terminates defrost and delays the evaporator fan operation on electric heat, hot gas and reverse cycle commercial refrigeration systems. Contact rating: 20 F.L. Amp @ 240 Vac
F25107 Temperature Range (F) 40 to 75 44 to 79 Temperature Differential (F) 20, Fixed 24, Fixed Capillary Length (In.) 60, Cross Ambient Bulb 60, Cross Ambient Bulb
FREEZESTAT
A11 SERIES
A11B1
The A11 Series low temperature cutout controls incorporate a 20 foot long, vapor charged, sensing element. These controls react to the coldest 18 inch section of the control sensing element. These controls are suitable for monitoring the face temperature of hot water coils for freeze protection.
Range (F) 35 to 45 35 to 45 Differential (F) Manual Reset 8, Fixed Ambient Range (F) 0 to 140 0 to 140
The most common application for these controls is as a low temperature cutout for coils and/or pipe liquid sensing Element: 20' of 1/8 O.D. tubing, 4' capillary Switch: SPSTopen low
Max. Element (F) 250 250 F.L. Amps (@ 240V) 8 8
A70HA1
The A70G, A70H, and A70K have a four-wire, two circuit contact block that contains two isolated sets of contacts. The contacts are designed so that when the main contact opens, the auxiliary contact closes. Typical applications would include energizing an indicator light upon low temperature cutout on a ventilating system.
Switch Main Auxiliary Open Low Close Low Open Low Open Low Open Low Open High Close Low Close Low Close Low Close High Range (F) 15 to 55 35 to 80 15 to 55 35 to 80 100 to 170 Differential (F) 5, Fixed 3 to 30 Manual Reset Manual Reset Manual Reset Bulb (In.) 1/8 O.D. Tubing 3/8 x 3 1/8 O.D. Tubing 3/8 x 3 3/8 x 10
Use as freezestat. A70GA1/A70HA1 only Low cutout stop is set and sealed at 35F (1.6C). Control responds only to the lowest temperature along any 1' of entire 20' element or bellows cup
928
TEMPERATURE
L480 SERIES
L480B1239
Used to limit or control temperature in air conditioning systems or refrigerated enclosures. Applications include freezer cabinets, display cases, beverage coolers, milk cooling tanks and air conditioners.
Switch SPDT SPST, Open Fall Reset Type Automatic Manual
Also used as frost alarm operator in storehouses or orchards where frost would damage crops or equipment. Maximum element temperature: 225F Contact rating: 6.5 F.L. Amps @ 240 Vac Temperature differential: 10F, fixed
(F) 20 to 60 20 to 60
No bulb
L482 SERIES
16A SERIES
Contact rating: 8 F.L. Amps (N.C.) @ 240 Vac 3 F.L. Amps (N.O.) @ 240 Vac Maximum element temperature: 400F
Designed to shut down cooling equipment before undesirably low temperatures are reached. Manual reset freeze protection control Switch: SPST, open fall Contact rating: 7.0 F.L. Amp @ 240Vac
Reset Part No. L482A1004 Switch Type 2-SPST (1 N.O., 1 N.C.) Manual
ELECTRONIC
REMOTE SENSOR, A320 SERIES REMOTE SENSOR, A319 SERIES
Operating ambient: -30 to 140F Humidity: 095% relative humidity Input voltage: 120/240 Vac, 50/60 Hz Current draw: 1.8 VA Remote sensing applications up to 800'
Part No. A320ABC1 Switch SPDT Range (F) -25 to 50 Differential (F) 1 to 15 F.L. Amps (@ 240 V) 8 Price 419.24 Part No. A319ABC2401 Switch SPDT
Operating ambient: -30 to 140F Humidity: 095% relative humidity Input voltage: 120 or 208/240 Vac, 50/60 Hz Current draw: 1.8 VA
Range (F) -20 to 100 Differential (F) 1 to 30 F.L. Amps (@ 240 V) 8
Price 313.30
A419ABC1
The A419 Series control is a singlestage, electronic temperature control with a single-pole, double-throw (SPDT) output relay. It has a lockable keypad, adjustable anti-short cycle delay, and binary input for temperature offset. Displays temperature and other function statuscustom icons indicate system status at a glance, digital display allows precise setpoint setting Concealed jumper deters unauthorized changes to control settings
Part No. A419ABC1 A419ABC2C A419AEC1C A419GBF1 A419GEF1C Enclosure NEMA 1 NEMA 1 NEMA 4X NEMA 1 NEMA 4X Switch SPDT SPDT SPDT SPDT SPDT Voltage 120, 208/240 120, 208/240 120, 208/240 24 24
Allows the user to shift the setpoint by an adjustable amount based on the status of an external switch, such as a time clock Notifies the user in the event of temperature sensor/wiring failure, and whether the circuit has failed open or shorted; allows the user to select output on or output off as the control default Allows the user to determine how rapidly the control can cycle the load off and on Current draw: 1.8 VA maximum Operating ambient: -30 to 140F Operation humidity: 095% relative humidity Remote sensing applications up to 800'
Range (F) -30 to 212 -30 -30 -30 -30 to to to to 212 212 212 212 Differential (F) 1 to 30 1 1 1 1 to to to to 30 30 30 30 F.L. Amps (@ 240V) 8 8 8 8 8 Price 136.92 138.34 201.20 132.94 194.50
929
TEMPERATURE
ELECTRONIC
PTC SENSOR, A99B SERIES REMOTE SENSOR, T7079 SERIES
Passive PTC silicon sensor (1035 at 77F) Exceptional accuracy of the sensing element provides excellent A99BB25C performance in a wide variety of applications Stainless steel sensing bulb allows use in applications that require more corrosion protection Lead length may be extended up to 800' Use with A419
Part No. A99BB25C A99BB200C A99BB300C A99BC25C A99BC100C A99BC300 Description PVC Cable PVC Cable PVC Cable Hi Temp Silicon Cable Hi Temp Silicon Cable Hi Temp Silicon Cable Length (In.) 9 3/4 78 117 9 3/4 39 2/3 24 3/8 Temperature Range -40F to 212F -40F to 212F -40F to 212F -40F to 248F -40F to 248F -40F to 248F Price 43.96 48.46 53.34 50.22 58.18 92.24
ETC211000
The T7079 electronic remote sensor temperature controller is capable of providing on-off temperature control for T7079A1012 ducts, tanks, heating and refrigeration units, greenhouses, animal confinement buildings, and other applications where electronic accuracy in addition to remote sensing is desired. Dual-stage output models can be configured as two-heat, twocool, or one-heat/one-cool. Contact rating: 4.9 FLA @ 230V, SPDT Differential adjustment: 1 to 30F, 0 to 35F interstage Switch selection of heat or cool mode Temperature sensing up to 400', 10K NTC temperature sensor included Does not require field calibration Wide setpoint temperature range LED annunciation for both power on and relay state Dual setpoint scale (F and C). Isolation transformer for 24 Vac input
Part No. T7079A1004 T7079A1012 T7079A1046 T7079A1053 T7079B1028 T7079B1036 T7079B1044 T7079B1051 Voltage 24 24 115/230 115/230 24 24 115/230 115/230 Number Relays/Stages 1 1 1 1 2 2 2 2 Range (F) -25 to 105 100 to 240 -25 to 105 100 to 240 -25 to 105 100 to 240 -25 to 105 100 to 240 Price 115.84 115.84 130.62 115.84 140.66 140.66 140.66 170.70
Wide temperature range: -30 to 220F Adjustable differential range: 1 to 30F LCD digital display: Sensor temperature, control settings, relay status, onboard diagnostics Remote temperature sensing: up to 400'; sensor included Lockout switch to prevent tampering Relay output 240V NO 1 stage controls - 8 FLA 2 stage controls - 4 FLA
Part No. ETC111000 ETC141000 ETC112000 Input Voltage (Vac) 120/240 120/240 24 120/240 120/240 24 Stages 1 1 1 2 2 2 Description 1309007044 NTC Sensor, 96", for all ETC 31.70 Enclosure NEMA1 Watertight, NEMA4 NEMA1 NEMA1 Watertight, NEMA4 NEMA1 Price 127.24 235.30 128.38 234.24 311.08 227.30
REMOTE SENSOR
Replaces most mechanical and electronic single stage controls using an SPDT output relay. Offers the widest multiple voltage operating range: 24/120/208/240 VAC Does not require a common wire when electrical load is greater than 2.5 amps Wide temperature range: -40 to 220F Adjustable differential range: 1 to 30F Remote temperature sensing: up to 400'; sensor included 8 FLA @ 240 Vac Alarm relay NO contact: 1 amp
Part No. 16E09101 Input Voltage (Vac) 24/120/208/240 Stages 1 Enclosure NEMA 1 Price 144.18
930
TEMPERATURE
REMOTE SENSOR, T775-2000 SERIES
Provide on/off, modulating, or reset control in applications where electronic accuracy in addition to remote sensing is desired Available with one or two temperature inputs and up to four SPDT relay output stages or modulating outputs Calibrate input sensors up to 10F for temperature and up to 10% of range for other sensors (e.g pressure, humidity) to compensate for resistance drops in longer sensor wire runs.
Two settable time periods per day are standard on all models Power: 24, 120, or 240 Vac; 50/60 Hz; Remote sensing from up to 1,000' Operating range: -40 to 140F Setting range: -40 to 248F Differential: 1 to 150F Contact rating: 4.9 FLA at 230V Analog modulating outputs can be individually configured for 0-10 Vdc, 2-10 Vdc, 4-20 mA or Series 90. The date and time settings are retained for 24 hours after a power outage. All other settings are stored permanently
Part No. T775A2009 T775B2016 T775B2024 T775B2032 T775B2040 T775M2006 T775M2014 T775M2022 T775M2030 T775M2048 T775R2001 T775R2019 T775R2027 T775R2035 T775R2043 T775U2006 T775U2016 T775L2007 T775P2003 T775S2008
Input Quantity 1 2 2 2 1 2 2 2 2 2 2 2 2 2 2 2 2 2 3
Relay 1 2 4 2 1 4 2 4 2 4 4 2 2 2 2 4(2) 4 4
Enclosure NEMA 1 NEMA 4X NEMA 4X NEMA 1 NEMA 1 NEMA 1 NEMA 4X NEMA 4X NEMA 1 NEMA 1 NEMA 1 NEMA 1 NEMA 1 NEMA 1 NEMA 1 NEMA 1 NEMA 1 NEMA 1 NEMA 1 NEMA 1
Comment Standard Standard, Floating Standard, Floating Standard, Floating Standard, Floating Modulating Modulating Modulating Modulating Modulating Outdoor reset, 2 sensors included Outdoor reset, 2 sensors included Outdoor reset, 2 sensors included Outdoor reset, 2 sensors included Outdoor reset, 2 sensors included Universal; Humidity, Pressure, Temperature (less sensor) Universal; Humidity, Pressure, Temperature. Control to Sensor A (Universal Input) or Sensor B (temp) Independently. Stage Sequencer with Reset Boiler Reset, 3 input sensors, digital alarm Relay Expansion Module only, use with T775L, T775P
Price 247.94 467.28 589.08 366.88 536.36 268.18 763.54 548.54 650.12 467.04 576.98 670.44 528.20 447.28 447.28 467.04 542.90 507.92 609.12 156.72
Description 2 5/8" L, 3/8" diameter, 6" leads Water resistant, 2" L, 1/4" diameter, 9' leads Outside Air Sensor, 8 5/16"L Strap On, Hot/Chilled Water Water resistant, 3 1/2" L, 1/4" diameter, 5' leads Water tight, 2" L, 1/4" diameter, 6' leads
Temperature Range (F) -40 to +257F -40 to +270F -40 to +158F -40 to +250F -40 to +270F -40 to +270F
931
TEMPERATURE
PROPORTIONAL, REMOTE BULB
MODULATING
For modulating control of water or air temperature in ducts, tanks and similar applications. Supply voltage: 2430 Vac Potentiometer resistance: 135 (T991A1269 - 280)
T991A1012 Part No. T991A1004 T991A1012 T991A1079 T991A1194 T991A1244 T991A1269 T991A1350 T991A1426 T991A1715 T991A1764 T991A2069 T991A1715 Throttling Range (F) 3 to 30 3 to 30 3 to 30 3.5 to 36 3.5 to 36 3.5 to 36 3.5 to 36 3 to 30 3 to 30 3 to 30 3 to 30 Capillary Length (Ft.) 5 20 20 20 5 20 24 5 5 24 20 Bulb (In.) 1/2 x 4 3/16 1/2 x 4 3/16 1/2 x 4 3/16 1/2 x 3 9/16 1/2 x 3 9/16 1/2 x 3 9/16 Averaging 1/2 x 4 3/16 Fast Response Averaging Fast Response Price 463.00 521.18 574.06 545.82 463.00 589.08 566.26 463.00 485.38 518.26 658.52
Temperature Range (F) 0 to 100 0 to 100 160 to 260 55 to 175 55 to 175 55 to 175 55 to 175 0 to 100 0 to 100 0 to 100 0 to 100
APPLIANCE
CONSTANT "CUT-IN"
The Ranco A12 controls provide a constant "cut-in" feature. The constant "cut-in" design is generally used to provide an "off" cycle defrost function. Each time the control cycles off, the control contacts will remain
A121506 Part No. A121506 A121560 A12700 A12701 Range (F) 9 to 22 19 to 29 11.5 to 26 15 to 31 Cut-In (F) 38 38 37 41
"open" until the evaporator is cleared of any frost that may have accumulated from the previous "on" cycle. Contact rating: 16 F.L. Amp @ 240 Vac
CONSTANT DIFFERENTIAL
A30260 Part No. A221112 A22391 A22392 A30180 A30181 A30182 A30183 A30184 A30185 A30260 A30261 A30262 A30263 A30301
Controls for commercial refrigerators, freezers, ice machines, vending machines and beverage coolers. These compact controls are readily adaptable to nearly all commercial refrigerators and freezers. A wide selection of temperature ranges, differentials and
Differential (F) 5 8 23.5 12 12 17 17 19 15.5 6 6 12 22.5 8.5
capillary lengths are available. Break-off shafts are included with installation instructions for easy, fast installation. Controls have "off" position except as noted. Contact rating: 20 F.L. Amp @ 240 Vac
Switch Capillary Length (In.) 72 66 48 42 84 42 84 42 42 72 84 84 84 84 Price 102.94 126.54 137.90 82.88 107.28 101.64 107.94 98.48 98.78 92.70 80.28 88.74 86.28 81.68
SPST, Open Low, No Off SPDT, No Off SPDT, No Off SPST, Open Low SPST, Open Low SPST, Open Low SPST, Open Low SPST, Open Low SPST, Open Low SPST, Open Low SPST, Open Low SPST, Open Low SPST, Open Low SPST, Open Low, No Off
932
TEMPERATURE
CONSTANT DIFFERENTIAL (Contd)
Part No. A30304 A30307 A30308 A30310 A30311 A30313 A30314 A30323 A302209 A302210 A302211 A302212 A30543 A303618 A303725 Range (F) -21.5 to 19.5 -23 to 23 -30.5 to 12.5 -24 to 23 -22 to 24 -20 to 21 -21.5 to 23 -11 to 10.5 35 to 48 30 to 42 -10.5 to 17.5 42.5 to 57 7 to 45 17 to 45 16 to 50 Differential (F) 15.5 23 11 20 14 8 8 10 8 8 10 6 12 17 19 Switch SPST, Open Low, No Off SPST, Open Low, No Off SPST, Open Low, No Off SPST, Open Low SPST, Open Low SPST, Open Low SPST, Open Low SPST, Open Low SPST, Open Low SPST, Open Low SPST, Open Low SPST, Open Low, No Off SPST, Open Low SPST, Open Low SPST, Open Low Capillary Length (In.) 84 78 84 36 42 42 54 48 48 48 48 48 27 30 60, w/Bulb Price 83.70 99.70 98.20 106.28 103.28 87.98 115.04 115.04 106.48 86.54 87.30 89.30 119.38 67.98 83.20
EVAPORATOR DE-ICE
WATER COOLER
Control is generally wired in series with cycling control and capillary senses evaporator temperature. When ice starts to accumulate on evaporator, control will shut off compressor.
Setting (F) Part No. A302311 Open 30 Close 60 Switch SPST Capillary Length (In.) 30 Price 98.38
Ranco's water cooler controls will replace about 80% of your control needs for equipment from such manufacturers as Ebco, Elkay, Sunroc, Halsey-Taylor, Kelvinator and General Electric. Contact rating: 6 F.L. Amp @ 250 Vac
Part No. Range (F) K3001 K3002 37 to 61 7 to 66 Differential (F) 7 27 Capillary Length (In.) 48 36 Price 79.18 79.88
Direct replacement control for ice machine applications. Provides narrow differential for accurate control of bin level. Contact rating: 20 F.L. Amp @ 240 Vac
Range (F) 35 to 51 Differential (F) 6 Capillary Length (In.) 48
OUTDOOR THERMOSTAT
Switch SPDT
Price 109.60
Ranco's C12-2001 control is an adjustable thermostat which holds back additional stages of supplemental heat until the outdoor temperature falls below the control's set point. The C122001 is typically wired through the relay circuit in conjunction with the indoor thermostat. Contact rating: 20 F.L. Amp @ 240 Vac
Part No. C122001 Switch SPDT Price 95.28
Adaptable replacement for ice machine applications. Contact rating: 20 F.L. Amp @ 240 Vac
-1 to 63
30, w/Bulb
PTAC
Differential (F) 8
Switch SPDT
This control replaces many OEM controls on heat/cool units. Contact rating: 20 F.L. Amp @ 240 Vac
ICE HARVEST
Range (F)
Differential (F)
933
TEMPERATURE
APPLIANCE
AUTO RESET, OPEN HIGH DISCHARGE FEEDBACK
PRESSURE
Discharge feedback thermostats types C17 and C22 are replacements for room, packaged terminal and throughthe- wall air conditioning units C179043 equipped for either manual or automatic heat/cool changeover. The C17 and C22 have separate switches for heating and cooling. A wide energy saving comfort zone ("dead band") is provided between heating and cooling cycles.
Range (F) Part No. C129024 C179043 Cool 67 to 83 68 to 86 Differential (F) 4 4 Capillary Length (In.) 36, w/Bulb; 36, w/Bulb 36, w/Bulb; 36, w/Bulb Price 156.50 178.58
Price 52.14
Adaptable control to replace OEM controls which govern the on/off compressor function. Contact rating: 20 F.L. Amp @ 240 Vac
A222453 Range Differential (F) (F) 60 to 91 5 45 to 81 59 to 90 58 to 89 58 to 91 5 6 5 5 Capillary Length (In.) 54, Cross Ambient 27 39, Cross Ambient 18, Air Coil 48
Switch SPST, Open Low SPDT SPDT SPST, Open Low SPST, Open Low
ENCAPSULATED
1/4" female flare connection 18" leads
AUTO RESET, OPEN HIGH
Part No. SHP200150 SHP250150 SHP275195 SHP300200 SHP350250 SHP375265 SHP400200 SHP400280 SHP400300 SHP425300 SHP425325 SHP450250 SHP610420
Pressure (psi) Open Close 200 150 250 150 275 195 300 200 350 250 375 265 400 200 400 280 400 300 425 300 425 325 450 250 610 420
Price 39.54 39.54 38.34 38.34 38.34 38.34 38.34 38.34 38.34 38.34 38.34 38.34 38.34
P100DA1 Pressure (psi) Open 410 475 630 Connection (In.) 1/4 1/4 1/4
934
PRESSURE
AUTO RESET
ENERGY MANAGEMENT
DISPLAY , THERMOSTAT
1/4" FFL with depressor pin Touchscreen The EcoView touchscreen is a full-color 7-inch tactile display device, master controller and internet gateway built CTPXBEE001 into a single wall-mounted unit. A single CAT5 cable provides both power (PoE, 48Vdc) and data and makes for a simple and robust field installation. Thermostat The EcoView Resource Manager is a wireless digital thermostat, designed to control the majority of HVAC systems. The Resource Manager contains a robust thermostat interface and is designed for use with communicating systems where remote monitoring and/or remote control are desired.
Part No. CTPXBEE001 CWTXBEE001 CRSWALL001 Description Ecoview Touch Panel Kit Ecoview Wireless Thermostat Ecoview Remote Wall Sensor Price 1754.30 622.86 77.14
SYSTEM 450
All System 450 modules are multipurpose and field configurable outof-the-box; each module is designed for use in temperature, pressure, and humidity systems. A System 450 control system can be easily assembled and configured to monitor and control temperature, pressure, and humidity simultaneously. Each control module can be set up as a stand-alone control or connected to expansion modules to control up to 10 outputs based on the input from up to 3 control sensors. A control systems outputs can be relay outputs (On/Off), analog outputs (0-10 VDC or 4-20 mA), or any combination of relay and analog outputs. Backlit Liquid Crystal Display (LCD) and 4-button touch pad User Interface (UI), provides quick, clear, visual status of the control systems input sensors and outputs with the touch of a button Up to 3 input sensors and up to 10 outputs allow you to build both simple and complex application specific control systems 4.9 F.L. Amps @ 240Vac
CONTROL MODULE
Part No. C450CBN2C C450CCN2C C450CPN3C C450CQN3C C450RBN1C C450RCN1C Description Control Module with 1 SPDT Output Relay Control Module with 2 SPDT Output Relays Control Module with 1 Analog Output (4-20 mA / 0-10 VDC) Control Module with 2 Analog Outputs (4-20 mA / 0-10 VDC) Control Module with 1 SPDT Output Relay, Temperature/Humidity Reset Capable Control Module with 2 SPDT Output Relays, Temperature/Humidity Reset Capable Price 206.00 257.50 206.00 257.50 293.56 360.50
CONTROLLER
Resource Meter The Resource Meter is the multi-phase power meter component of the EcoView System. Capable of measuring three phase four wire 240V wye and delta systems of up to 1200 Amps along with single phase three wire (residential) systems. The unit also has the ability to interface to third party water and gas meters via two pulse inputs. Self powered from "A" phase but 24V input capable for low voltage installs Resource Controller An eight channel pilot duty controller module to manage lighting, ventilation and any energy consuming electrical load that would benefit from scheduling Accessed via touch screen module or EcoView web
Part No. CRCXBEE001 CRM208Y001 CRM408Y001 CRMDLTA001 Description Resource Controller, 8 Channel Resource Meter, 208V Commercial Resource Meter, 480V Commercial Resource Meter, 240V Commercial Price 771.44 748.58 958.00 958.00
TRANSDUCER
Price 103.00 190.56 103.00 190.56 Part No. CCT0200001 CCT0800001 CCT1200001 Price 72.10 CCT2000001 CCT3000001 Amps 200 800 1200 2000 3000 Dimension (In.) Inside 1.25 3.5 x 3.5 4.0 x 4.0 4.5 x 4.0 4.5 x 4.0 Outside 3.4 6.1 6.2 7.2 7.2 Price 597.18 620.00 680.00
Current transducers for use with resource meters. Provided in sets of three.
POWER MODULE
Part No. Description C450YNN1C Provides 24 V to System 450 Module Assembly; 120 or 240 VAC Supply Power Input Terminals
935
PRESSURE
936
PRESSURE
937
PRESSURE
ADAP-KOOL
SYSTEM CONTROLLER EKC CONTROLLER
The feature-filled AK-SC255 system controller is the heart of your control and monitoring system. It gives you a brilliant full color high resolution display, context-sensitive soft keys, easy navigation to every part of your system, an on-board Ethernet port, a complete suite of maintenance management tools, extensive alarm capability, and much more. Advantages Supports Pack, Evaporator controllers, I/O Modules Temperature monitoring and Alarming Enables HACCP Compliance Local access with key-pad and VGA screen Full remote access (serial, Internet) Energy optimization with adaptive master control Lighting Control Off Line programming allowing for off site commissioning Host Network connect up to 10 AK2-SC255 units to cover massive application range Alarm via e-mail Scalable solution from convenience store to hypermarket Regulating The AK-SC 255 will control and monitor up to 5 suction and condensing groups, with up to 40 circuits per suction group. With its compressed storage, it provides a huge history capacity. There is a userprogrammable logic processor for custom strategies. Standard and custom alarms protect food products and equipment. Software options can include up to 30 lighting zones, including motorized panels, and up to 40 HVAC systems. Network The AK-SC 255 can control and monitor multiple network types to suit different levels of application. Communication types include; TCP/IP EKC controllers Modbus EKC controllers LonWorks TP78, FTT10, RS 485 AK- & EKC LonWorks AK I/O Modules Lighting 5 lighting zones 6 relays per zone Standard or relative schedules 8 schedules per zone Auto override for burglar or fire alarm Switch override with OVR override box
Part No. 080Z2500 080Z2550 080Z2502 080Z2582 Description System Controller, AK2-SC255, VGA Display, Refrigeration only System Controller, AK2-SC255, VGA Display, C-Store System Controller, AK2-SC255, VGA Display, refrigeration, HVAC and lighting System Controller, AK2-SC255, no display, refrigeration, HVAC and lighting Price 4567.70 5026.68 4977.00 2386.00
084B8521 Part No. 084B8521 084B8522 084B8534 084B8565 60 274 Description EKC Controller, EKC202A, 220V (Ref/Def or Alarm) EKC Controller, EKC202B, 220V (Ref/Def/Fan) EKC Controller, EKC204A, 115V (10 output configs) Data Com Module, EKA-179, LON to RS485 Bracket, Metal for EKC Price 162.18 191.50 258.78 155.28 100.48
I/O MODULE
080Z0007 Part No. 080Z0007 080Z0010 080Z0017 080Z0032 080Z0018 080Z0020 080Z0061 AK21O8 080Z0290 Description Extension Module, AK2-XM 101A, 8 Analog Inputs Extension Module, AK2-XM 205A, 8 Analog Inputs, 8 Digital Outputs Extension Module, AK2-XM 205B, 8 Analog Inputs, 8 Digital Outputs Extension Module, AK-XM 103A, 4 Analog Inputs, 4 Analog Outputs Extension Module, AK2-XM 204B, 8 Digital Outputs Extension Module, AK2-XM 107A, 8 Pulse Inputs Communications Module, AK2-CM 101A, Lonworks TP78 Enclosure, 1Row x 4 Modules, Includes Power and Comm Module Din Rail, AK2 Modules Price 386.18 864.28 864.28 800.00 612.38 551.68 312.64 1666.68 36.78
SENSORS
080Z2172 Part No. 080Z2171 080Z2172 080Z2185 ASTP2 PHOTO ID Description Humidity with Temperature Sensor, Indoor Photocell with Temperature Sensor, Outdoor Box Temperature Probe Assembly Air Supply Duct Probe Sensor Photocell, Indoor Price 1103.90 497.40 214.28 158.20 478.30
938
PRESSURE
TRANSDUCERS, TRANSFORMERS, RELAYS DOOR MONITOR SWITCH ASSEMBLY
C20106603 Part No. CTB0600 CTB0800 WATTNODEP1 C20106603 C20106605 49 100 55 168 41 062 Description Transducer, Split Core Buss, 600A, Wattnode CT Transducer, Split Core Buss, 800A, Wattnode CT Wattnode Plus Power Meter, requires 3 Wattnode CTs Transducer, 800A, 3, incl 3 CTs, Veris Transducer, 1600A, 3, incl 3 CTs, Veris Current Sensing Relay Transformer, 150VA, Wall Mount, 24V Relay, Form C, 2 Pole, 24V Coil Price 707.28 707.28 2868.60 2033.34 2333.34 235.28 358.24 85.54
Magnetic contact switch that provides a signal to your Danfoss environment control system to ensure that the doors on refrigerated walk-in boxes are properly closed when not in use. Typically set to alarm in the closed position, indicating that a door has been left open. Compatible with all Danfoss AK255 controllers as well as legacy controllers (AKC55, NC-25)
Part No. DRMON 1 Description Magnetic Contact Switch: 120 VAC, N.O. Price 141.90
SINGLE FUNCTION
ELECTRONIC LOW PRESSURE TIME DELAY
More than 50,000 items in stock and available for immediate shipment.
Voltage 120/208-230 24
The P470 Electronic Pressure Control with Display is a single-stage, On/Off, electronic pressure control with an SPDT output relay (open high or low). P470FB1 The P470 control uses a P399 Electronic Pressure Transducer to generate a pressure signal and WHA-P399 Wiring Harness, which eliminates many of the constraints of capillary-tube control applications. (MUST BE ORDERED SEPARATELY) Easy-to-read liquid crystal display (LCD) clearly displays the sensed pressure (and other control information), and in many situations pressure may be monitored without applying gauges to the controlled equipment. LED indicates relay status Three field-selectable pressure ranges between 0-750 psi (transducer dependent) provide the flexibility to cover most HVAC/R pressure applications Lockable, 3-button, front-panel touchpad deters tampering and over adjustment of control settings by unauthorized personnel. Built-in, adjustable, anti-short cycle time-delay reduces compressor short cycling and nuisance lockouts, which can extend compressor life Economical, versatile transducer and wiring harness eliminate many of the constraints of capillary control applications and allow up to a 100 ft (30.5m) cable between control and transducer
P29NC provides a low pressure cutout control with time delay and lockout, which requires manual reset. Standard time delay is 60 seconds. The control P29NC3 provides equipment shutdown on extended low pressure conditions. The time delay prevents nuisance shutdowns due to momentary fluctuations in system pressures. Applications: chiller low temperature cutout; industrial equipment, oil pressure lubrication cutout; low suction pressure cutout Maximum bellows pressure: 325 psig Pressure drop to close contacts: 13 psi
Part No. P29NC2 P29NC3 Switch SPST SPST Range (psi) 20 to 100 20 to 100 Pressure Connection (In.) 1/4 M Flare 1/4 F Flare; 36" Capillary Price 343.90 343.90
939
PRESSURE
SINGLE FUNCTION
The P70 controls employ a set of switch contacts that are opened and closed by the movement of a pressure actuated bellows. Typical applications for these controls include system control of air conditioning and refrigeration systems and limit protection for system components. These controls can be used in the control of air, water, and oil pressure.
P170AA118
P70AA118
FAN CYCLING
Switch SPST, Open Low SPST, Open Low SPST, Open Low SPST, Open Low SPST, Open Low DPST, Open Low
Range (psig) 100 to 400 100 to 400 0 to 150 100 to 470 50 to 300 100 to 400
Connection (In.) 1/4 F Flare 1/4 M Flare 1/4 F Flare 1/4 F Flare 1/4 FPT 1/4 F Flare
HIGH PRESSURE
Part No. P170AA2C P170AA400C P70CA2 P70CA3 P170CA3 P70DA1 P170DA1 P70CA51 P70DA21 P170CA400C P70CA400C P170DA400C P70DA400C P72CA2 P72DA1
1
Switch SPST, Open Low SPST, Open Low SPST, Open High SPST, Open High SPST, Open High SPST, Open High SPST, Open High SPST, Open High SPST, Open High SPST, Open High SPST, Open High SPST, Open High SPST, Open High DPST, Open High DPST, Open High
Max. Working Pressure (psig) 525 psig 525 psig 525 psig 525 psig 525 psig 525 psig 525 psig 525 525 690 690 690 690 525 525 psig psig psig psig psig psig psig psig
Range (psig) 0 to 150 100 to 470 50 to 500 50 to 500 50 to 500 50 to 500 50 to 500 50 to 500 50 to 500 200 to 610 200 to 610 200 to 610 200 to 610 50 to 500 50 to 500
Differential (psi) 10 to 70 35 to 200 60 to 150 60 to 150 60 to 150 Manual Reset Manual Reset 60 to 150 Manual Reset 60 to 150 60 to 150 Manual Reset Manual Reset 60 to 150 Manual Reset
Connection (In.) 1/4 M Flare 1/4 M Flare 1/4 M Flare 1/4 F Flare 1/4 M Flare 1/4 F Flare 1/4 M Flare 1/4 FPT 1/4 FPT 1/4 MFL 1/4 MFL 1/4 MFL 1/4 MFL 1/4 F Flare 1/4 F Flare
Capillary Length (Ft.) None None None 3 None 3 None None None None 3 None 3 3 3
Price 156.90 146.96 159.68 172.94 160.90 173.68 170.00 304.96 316.18 159.68 172.94 170.00 172.80 258.16 268.00
LOW PRESSURE
Switch SPST, Open Low SPST, Open Low SPST, Open Low SPST, Open Low SPST, Open Low SPST, Open High
940
PRESSURE
LOW PRESSURE (Contd)
Part No. P170CA1 P70AA51 P70CA41 P70EA10 P72AA1
1
Switch SPST, Open Low SPST, Open Low SPST, Open High SPDT DPST, Open Low
Range (psig) 20" to 100 20" to 100 20" to 100 20" to 100 20" to 100
Connection (In.) 1/4 M Flare 1/4 FPT 1/4 FPT 1/4 M Flare 1/4 F Flare
P20 SERIES
The P20 Series are slim profile, field replacement high and low pressure controls for non-corrosive refrigerants. Maximum temperature: 140F Contact rating: 8 F.L. Amp @ 240V
P20BB1 Part No. P20BB1 P20DB1 P20EB1 P20EB2 Switch SPST, Open Fall SPST, Open Rise SPDT SPDT Range (psig) 7 to 150 100 to 425 7 to 150 100 to 425 Differential (psi) Manual Reset Manual Reset 30, Fixed 75, Fixed Max. Bellows (psig) 250 450 250 450 Price 116.20 126.34 110.90 120.82
SINGLE FUNCTION
0101402 Range (psi) 12" to 50 12" to 50 10" to 100 10" to 100 100 to 400 100 to 400 150 to 450 100 to 400
Type 010 SPST for single phase and 020 DPST for double break or 3-phase applications provides close-on-rise switch action for conventional low pressure cycling, pump down, limit, defrost termination, and alarm applications.
Differential (psi) 5 to 35 5 to 35 10 to 40 10 to 40 40 40 50 40 to to to to 150 150 100 150 Switch SPST, Open Low SPST, Open Low SPST, Open Low SPST, Open Low SPST, Open Low SPST, Open Low SPST, Open High DPST, Open Low
Type 011 SPST open-on-rise is typically unloader applications. Contact rating: 24 F.L. Amp @ 240 Vac 020 DPST switch: 12 F.L. Amp @ 240 Vac
Connection Size 1/4 SAE 1/4 SAE 1/4 SAE 1/4 SAE 1/4 1/4 1/4 1/4 SAE SAE SAE SAE Gender M F F M M F F F
used
for
Part No. 0101401 0101402 0101483 0101831 01018941 01020541 0111711 0207006
1
16108 Range Part No. 016107 0161081 016120 016142 016166 016200 016209 016261 016527 016557 0165701 016585 016624
1
These controls offer a variety of pressure ranges and switch action to provide maximum application flexibility. Type 016 SPDT switch action can be used for all categories of applications. If desired, the unused terminal may be wired to an alarm.
Differential (psi) 10 to 40 40 to 150 5 to 35 17, Fixed 10 to 40 Manual Reset Manual Reset Manual Reset 10 to 40 5 to 35 40 to 150 Manual Reset 4 to 38 Switch SPDT SPDT SPDT SPDT SPDT SPDT, Locks on Increase SPDT, Locks on Increase SPDT, Locks on Decrease SPDT SPDT SPDT SPDT, Locks on Decrease SPST, Opens Low (psi) 10" to 100 100 to 400 12" to 50 100 to 400 50 to 150 150 to 450 150 to 450 10" to 100 10" to 100 12" to 50 100 to 400 10" to 100 12" to 80
Note: Since an alarm circuit is frequently desired on manual reset controls, all manual reset controls are provided in the Type 016 SPDT configurations. Contact rating: 24 F.L. Amp @ 240 Vac
Connection Size 1/4 SAE 1/4 SAE 1/4 SAE 1/4 SAE 1/4 SAE 1/4 SAE 1/4 SAE 1/4 SAE 1/4 SAE 1/4 SAE 1/4 SAE 1/4 SAE 1/4 SAE Gender M F M F F F M F F F M M F Price 134.30 140.18 139.24 154.38 152.18 152.18 162.18 173.90 137.50 152.04 151.70 165.98 121.88
941
PRESSURE
SINGLE FUNCTION
SPST, SPDT SWITCH
0605233
Snap action electrical contacts The fail-safe dual bellows used in 600 psi controls prevent refrigerant loss and enable premature cut-out when a fault occurs Manual trip allows electrical function test without tools Repeatability less than 0.1 psi drift, even after 400 000 cycles Contact rating: 24 F.L. Amp @ 240 Vac
Range Differential (psi) 10 to 60 psi 10 psi fixed 6 to 30 psi 6 to 30 psi 6 to 30 psi 10 psi fixed 25 to 85 psi 25 to 85 psi 58 to 145 psi 58 to 145 psi 60 psi fixed 60 psi fixed Switch SPDT SPDT SPST, open low SPST, open low SPDT SPDT, Man Reset SPST, open low SPST, open low SPDT SPDT SPDT, Man Reset SPDT, Man Reset Capillary Length (Ft.) 3 3 None 3 None None None 3 None 3 3 None Size 1/4 SAE 1/4 SAE 1/4 SAE 1/4 SAE 1/4 SAE 1/4 SAE 1/4 SAE 1/4 SAE 1/4 SAE 1/4 SAE 1/4 SAE 1/4 SAE Connection Gender F F M F M M M F M F F M Price 106.50 122.24 99.38 106.50 99.38 98.40 99.38 106.50 110.58 118.78 120.94 111.80 (psi) 6" to 108 28" to 100 6" to 73 6" to 73 6" to 73 45 fixed 100 to 465 100 to 465 100 to 600 100 to 600 100 to 600 100 to 600
Part No 060 5233 060 5234 060 5237 060 5235 060 5239 060 060 060 060 060 060 5270 5241 5242 5243 5245 5246
060 5244
DUAL PRESSURE
This P70 Series of dual pressure controls employs an SPST switch, that is opened when either high pressure or low pressure beyond the control settings is sensed at the controls two bellows sensing elements.
P70LB1
P170LB1
SINGLE POLE
High pressure range: 100500 psig High pressure differential: 65 psi < 300 psig 75 psi 300400 psig 95 psi > 400 psig
Part No. Low Pressure Range (psig) 20" to 100 20" to 100 12" to 80 12" to 80 12" to 80 20" to 100 20" to 100 20" to 100 20" to 100 20" to 100 20" to 100 Differential (psi) 7 to 50 7 to 50 5 to 35 5 to 35 5 to 35 7 to 50 7 to 50 Manual Reset Manual Reset 7 to 50 7 to 50
Maximum over pressure: 475 psig Low 525 psig High Contact rating: 17 F.L. Amp @ 240V
High Pressure Reset Auto Auto Auto Auto Manual Manual Manual Manual Manual Auto Manual Connection (In.) 1/4 F Flare 1/4 M Flare 1/4 F Flare 1/4 M Flare 1/4 F Flare 1/4 F Flare 1/4 M Flare 1/4 F Flare 1/4 M Flare 1/4 FPT 1/4 FPT Capillary Length (Ft.) 3 None 3 None 3 3 None 3 None None None
Price 291.32 278.04 291.32 278.04 291.00 294.24 285.94 296.96 287.12 557.58 570.84
P70LB1 P170LB1 P70LB62 P170LB62 P70MA182 P70MA1 P170MA1 P70NA1 P170NA1 P70LA21 P70MA21
1
942
PRESSURE
TWO POLE
High pressure range: 100425 psig Differential: 55 psi < 300 psig 65 psi 300 psig
Part No. P72LA1 P72LB1 P72MA1 P72NA1 Switch DPST DPST DPST DPST Low Pressure Range Differential (psig) (psi) 20" to 100 6 to 50 20" to 100 6 to 50 20" to 100 6 to 50 20" to 100 Manual Reset
Maximum over pressure: 525 psig Contact rating: 24 F.L. Amp @ 240V
Connection (In.) 1/4 F Flare 1/4 F Flare 1/4 F Flare 1/4 F Flare
Length (Ft.) 3 3 3 3
SINGLE POLE
These controls offer a tailored variety of ranges and options for refrigerants. Low and high pressure functions are combined into a single control with one switch.
0124834 Low Side Range Differential (psig) (psi) 12" to 50 5 to 35 12" to 50 5 to 35 12" to 50 5 to 35 10" to 100 10 to 40 10" to 100 10 to 40 10" to 100 Manual 12" to 50 5 to 35 10" to 100 10 to 40 10" to 100 10 to 40 10" to 100 10 to 40 10" to 100 10 to 40 High Range (psig) 150 to 450 100 to 250 100 to 250 150 to 450 150 to 450 150 to 450 150 to 450 150 to 450 150 to 450 150 to 450 150 to 450 Side Differential (psi) 70, Fixed 50, Fixed 50, Fixed 70, Fixed 70, Fixed Manual 70, Fixed 70, Fixed 70, Fixed 70, Fixed 70, Fixed
"Convertible" (auto or manual) reset or automatic high pressure reset models Contact rating: 24 F.L. Amp @ 240 Vac 022 DPST switch: 12 F.L. Amp @ 240 Vac
Capillary Length (Ft.) 3 None 3 3 None 3 4 4 3 None 3
Reset Low Automatic Automatic Automatic Automatic Automatic Manual Automatic Automatic Automatic Automatic Automatic High Automatic Automatic Automatic Automatic Automatic Manual Convertible Convertible Convertible Convertible Convertible
Part No. 0121502 0121505 0121506 0121549 0121550 0121594 0124833 0124834 0124840 0124846 0227706
Connection Size Gender 1/4 SAE F 1/4 SAE M 1/4 SAE F 1/4 SAE F 1/4 SAE M 1/4 SAE F 1/4 SAE F 1/4 SAE F 1/4 SAE F 1/4 SAE M 1/4 SAE F
Price 256.84 242.34 256.90 242.58 237.80 261.60 250.00 237.60 277.24 244.84 334.38
SINGLE POLE
0605247
Snap action electrical contacts, 24 F.L.A at 240V The fail-safe dual bellows used in 600 psi controls prevent refrigerant loss and enable premature cut-out when a fault occurs Manual trip allows electrical function test without tools Repeatability less then 0.1 psi drift, even after 400 000 cycles
Low Side Range Diff. (psig) (psi) 6" to 108 10 to 60 6" to 108 10 to 60 6" to 108 10 to 60 6" to 108 10 to 60 6" to 108 10 to 60 6" to 108 10 to 60 High Side Range Diff. (psig) (psi) 100 to 465 60 fixed 100 to 465 60 fixed 100 to 465 60 fixed 100 to 465 60 fixed 100 to 600 60 fixed 100 to 600 60 fixed Reset Low High Automatic Automatic Automatic Automatic Automatic Manual Automatic Manual Convertible Convertible Convertible Convertible Capillary Length (Ft.) None 3 None 3 None 3 Connection Size Gender 1/4 SAE M 1/4 SAE F 1/4 SAE M 1/4 SAE F 1/4 SAE M 1/4 SAE F
Part No
Price
943
PRESSURE
CONTROL HOSE
Uniweld's Super Black Magic hoses for permanent installation are long lasting, trouble free alternatives to traditional copper capillary tubing used on refrigerant pressure and oil cutout H024A409A controls. Maximum operating pressure: 500 psi Burst pressure: 2500 psi Maximum working temperature: 250F 1/4" fem flare x 1/4" 90 fem flare
Part No. H018A409A H024A409A H030A409A H036A409A H048A409A H060A409A Length (In.) 18 24 30 36 48 60 Price 19.54 20.46 21.38 22.30 24.16 26.00
The UltraCap armored capillary is designed for use as a pressure connection in refrigeration and AC applications. The small orifice capillary minimizes pressure pulsation and the brass armor sleeve improves resistance SEC99AA36C to abrasion caused by vibration. Tubing ID: 0.062", 1/4" fem. flare straight UL recognized
Part No. SEC99AA24C SEC99AA36C SEC99AB18 SEC99AB24 SEC99AB36 SEC99AB48 SEC99AB60 SEC99AD18 SEC99AD24 SEC99AD36 SEC99AD48 Length (In.) 24 36 18 24 36 48 60 18 24 36 36 Configuration Straight, 1 depressor Straight, 1 depressor 90 x Straight, depressors 90 x Straight, depressors 90 x Straight, depressors 90 x Straight, depressors 90 x Straight, depressors 90 x Straight 90 x Straight 90 x Straight 90 x Straight Price 39.16 45.60 35.96 39.20 45.60 52.06 58.46 35.56 38.90 45.58 52.26
Replaces regular copper capillary tubing on failure cut out controls and pressure controls. Eliminates capillary failure due to work hardening from vibration Operates to 600 psi and 252F 1/4" female flare x 1/4" female flare
Part No. 1290132B24 1290132B36 1290132B48 Length (In.) 24 36 48 Configuration Straight x Straight Straight x Straight Straight x Straight Price 66.10 75.48 98.44
CONTROL PUMP
Quickly and accurately test and set single or dual pressure controls to 350 psi and 25 inches of vacuum. Use with gauge manifold
Part No. 40200 Description Control Pump Price 204.67
Maximum operating pressure: 600 psi Burst pressure: 3000 psi 1/4" fem flare x 1/4" 90 fem flare
The P266 fan speed control is designed for approved single phase, PSC motors commonly used in a wide variety of refrigeration and air conditioning condenser fan applications. Designed to replace P66 and P215 Series fan speed controls. P266 controls have current ratings from 4 to 12 A depending on the voltage and model. Wide, adjustable pressure throttling range Optional auxiliary fan control provides control of up to three fixedspeed fans or fan stages in conjunction with the speed controlled fan or fan stage. Optional low-speed capacitor mode enables cooler, quieter, and more efficient fan motor operation at low speeds. NEMA 3R, (IP54) enclosure with integral metal heat-sink
High Aux. Fan Max Voltage VAC Triacs Control Circuits Amps Price 208 to 240 Vac 3 3 8 637.94 208 to 240 Vac 1 0 8 533.20 440 to 575 Vac 1 0 4 538.30 440 to 575 Vac 2 3 4 659.36
Part No. NPCH30 Part No. NPCH18 NPCH24 NPCH30 NPCH36 NPCH48 NPCH60 Length (In.) 18 24 30 36 48 60 Price 48.30 51.80 57.90 60.90 68.30 79.10 P266ABA100C P266ACA100C P266BCA100C P266BHA100C
PRESSURE TRANSDUCER
Electronic pressure transducer for P266 fan speed control modules Includes 6.6' cable 1/4 FFL connection
Part No. P266SNR1C P266SNR2C Pressure Range (psi) 0 to 508 0 to 754 Price 168.30 168.30
944
PRESSURE
TEMPERATURE/PRESSURE RESPONSIVE PRESSURE TRANSDUCER
PRESSURE TRANSDUCER
Price 1145.30
1883.80
2000.82
Digitally compensated sensor All metal wetted parts for use in wide variety of fluid applications Suitable for use with freon and ammonia based cooling systems No internal elastomeric seals mean no o-ring compatibility issues Less than 2 ms response time provides accurate, high speed measurement Output signal: 2-wire 4-20mA Includes 3-meter cable
Part No. 50035430500 Accuracy 0.25% FSS Pressure Range (psi) 0 to 500 Connection Size (In.) 1/4" FFL Schrader Price 210.40
Regulate the speed of three-phase condenser fan motors in refrigeration and HVAC systems. Condenser fan speed may be controlled by pressure or temperature. The VFD66 Series accept input signals from the P35 Pressure Transducer, P499 Electronic Pressure Transducer, System 450 controls, or any other device that provides a 0 to 5 VDC or 0 to 10 VDC analog input signal. The VFD66 Series feature a simple interface using a display and keypad. The controls are user friendly and highlight the basic parameters that are required for setup, as outlined in the literature included with the product. Features Ground fault protection extends the life of the control Keypad interface allows for easy setup Isolated input circuitry permits application with 0 to 5 VDC or 0 to 10 VDC controllers, sensors, and transducers Alarm output is standard on all models Simultaneous acceptance of two similar inputs allows use on dual refrigeration circuits cooled by a single fan Adjustable acceleration and deceleration timing parameters allow independent timing settings to meet the requirements of the application Adjustable Pulse Width Modulated (PWM) frequency settings of 3, 6, 9, or 12 kHz correspond to a variety of applications Applications The VFD66 controls are intended for air-cooled condenser fan speed control in refrigeration and HVAC applications: Commercial air-cooled condensers Cooling tower fans Fans in evaporative condensing units The VFD66 controls allow the system to: Maintain optimum condenser head pressure in low ambient temperature conditions Eliminate short cycling in low ambient or changing load conditions Match the condenser fan speed to the load on the condenser, which increases the efficiency of the refrigeration system. This can reduce electricity cost and help maintain a constant evaporator Stabilize condenser head pressures, which helps optimize compressor operation and can reduce wear and extend compressor life Eliminate condenser fan short cycling, which can reduce motor repair and replacement costs Stabilize evaporator temperatures, which can extend refrigerated product life and provide more consistent comfort cooling
The electronic pressure transducer is a compact, economical, rugged, directmount pressure transducer designed to produce a low-voltage analog signal P499RCP101 (nominal 0.5 to 4.5 Vdc) based on the sensed pressure. They are designed for use in commercial refrigeration and airconditioning applications. These are suitable for use with all noncorrosive refrigerants as well as ammonia. P499 transducers require wire harnesses for all models that do not have an integral cable. Kits include a 6 1/2' wire harness.
PRESSURE TRANSDUCER 1/8" MPT
Part No. P499RAP101C P499RAP102C P499RAP105C P499RAP101K P499RAP105K P499RAP107K Pressure Range (psi) 0 to 100 0 to 200 0 to 500 0 to 100 0 to 500 0 to 750 Description Individual Individual Individual Kit Kit Kit Price 189.22 189.22 189.22 211.66 211.66 211.66
WIRING HARNESS
with
499
pressure
945
PRESSURE
HEAD PRESSURE, FAN SPEED CONTROL
TEMPERATURE RESPONSIVE TEMPERATURE RESPONSIVE
The FM2000A and FM4000A low ambient controllers, by modulating the condenser fan motor, eliminate the on/off shocking of the condenser section FM4000 that you get with fan cycling controls. Operating ambient: -30 to 135F Unit provided with 1 sensor SK2010; sensor for dual circuit or replacement
Maximum Part No. FM2000 FM4000 SK2010 F.L. Amp 5 10 Description Sensor, for Dual Circuit, Replacement 25.00 Suggested Horsepower 1/20 to 1/2 1/20 to 1 Price 227.28 254.50
Integral heat pump bypass circuitry allows electronic bypass of speed control during heat pump operation Features: Hard start, low ICM325HNC temperature cutoff, high temperature bypass Controls up to 3 refrigerant circuits Varies motor speed Kit includes 70100F probe ICM325HNC requires 18-30Vac input, ICM326HNC, ICM327HNC have internal transforms; operate from controlled voltage Output currentTriac maximum: 10 amps minimum: 100 mA ICM32*HN* models are RoHS compliant (lead free)
Part No. ICM325HNC ICM326HNC ICM327HNC Controlled Voltage (Vac) 120/208/240/480 120/208/240 480 Price 197.90 223.84 260.60
SENSOR PROBE
ICM379 Temperature Part No. ICM376 ICM379 Range (F) 70 to 100 70 to 100 Use With ICM325K2 ICM32*H Series Price 47.06 47.06
LUBE OIL
ELECTROMECHANICAL
P28AA1
P128AA1
The P28 series provides dependable shutdown on pressure of lubricated refrigeration compressors by sensing low lube oil pressure. A built-in time delay switch, accurately compensated for ambient temperature, allows for pressure pick up on start and avoids nuisance shutdowns on pressure drops of short duration during the running cycle. Heater circuit: 120/240 Vac Range: 870 psig
Pressure Connection (In.) 1/4 F Flare 1/4 M Flare 1/4 F Flare 1/4 M Flare 1/4 F Flare 1/4 M Flare 1/4 F Flare 1/4 F Flare 1/4 F Flare 1/4 F Flare Capillary Length (Ft.) 3 None 3 None 3 None 3 3 3 3 Price 367.28 351.20 367.28 351.20 367.28 351.20 367.28 378.08 379.16 601.54
Part No. P28AA1 P128AA1 P28AA2 P128AA2 P28AA17 P128AA17 P28AA18 P28GA2 P28NA51 P28AN12
1
Reset Manual Manual Manual Manual Manual Manual Manual Automatic Manual Manual
946
PRESSURE
ELECTROMECHANICAL, COPELAND, CARLYLE
P145NCA12
P45NCA12
The P45 control provides dependable, low lube oil pressure cut out for lubricated refrigeration compressors. The factory set pressure provides operation to the compressor manufacturer's specification. A built-in time delay relay, compensated for ambient temperature, allows for pressure pick-up on start and avoids nuisance shutdowns on short duration pressure losses during the running cycle. Max. bellows pressure: 425 psig Manual reset
Pressure Connection (In.) 1/4 F Flare 1/4 F Flare 1/4 M Flare 1/4 M Flare 1/4 F Flare 1/4 M Flare 1/4 M Flare Capillary Length (Ft.) 3 3 None None 3 None None Alarm Circuit No No No Yes No No Yes Usage Copeland Copeland Copeland Carlyle Carlyle Carlyle Price 352.80 328.70 313.58 339.70 328.70 313.58 339.70
Heater Circuit 24 Vac 120/240 Vac 120/240 Vac 120/240 Vac 120/240 Vac 120/240 Vac 120/240 Vac
Factory Setting (Lbs.) 9.0 9.0 9.0 9.0 6.5 6.5 6.5
P545NCB82
The P545 Series electronic lube oil control is designed for use on refrigeration compressors equipped with an oil pump that accepts a single-point differential pressure transducer. The P545 senses net lube oil pressure and de-energizes the compressor if lube oil pressure falls below the manufacturer's recommendation for longer than the time delay. Frontmount LEDs indicate the status of the lubrication
Delay (Sec.) 120 sec 120 sec 90 sec Description Replacement Sensor Replacement Sensor Open (psid) 7.01.0 12.750.75 10.01.5 Open (psid) 7.01.0 12.750.75
system and a user selectable time delay can be set to minimize compressor short cycling. P545 controls include pressure sensor and wiring harness P400 series sensors will adapt to either 300 or 400 series wire harness; test switch will not function with an older control
Application Copeland Carlyle Bitzer Application Copeland Carlyle Price 340.00 340.00 342.24 234.34 234.34
ELECTROMECHANICAL
P305826
Capillary Connection (In.) 36, 1/4 Female SAE 36, 1/4 Female SAE
These lube oil protection controls guard pressure lubricated refrigeration compressors against major damage due to loss of oil pressure. If adequate oil pressure is lost, the built-in S30 time delay switch starts timing. If the oil pressure does not recover within the set period, the control circuit is opened, stopping the compressor.
The range is the difference between the crankcase pressure and the oil pump pressure that will energize the time delay switch and lead to shutdown. The difference in oil pressure needs to rise 7 psi above the range to de-energize the time delay switch and prevent eventual shutdown. Voltage: 120/240 Vac
947
PRESSURE
LUBE OIL
ELECTROMECHANICAL
Oil differential pressure controls are used as safety switches to protect refrigeration compressors against low lubricating oil pressure. If the oil pressure fails, the control will stop the compressor after a predetermined time period has elapsed. Simple manual trip, electrical test function 060B2012 includes normal compressor operation eliminates need of tools and jumper wires check light; goes off on time delay initiation Extremely narrow switch differential accuracy Range: 29" to 170 psi, p either factory set or adjustable
Part No. 060B2002 060B2003 060B2008 060B2012 Time Delay 90 120 45 60 Differential (psi) 9, fixed 9, fixed 6, fixed 4.3 to 64, adjustable Connection (In.) 1/4 M Flare 1/4 M Flare 1/4 M Flare 1/4 M Flare Price 256.70 256.70 256.70 278.90
V46AB1
V46AS1
Maximum water temperature: 170F Maximum permissible pressure: Water: 150 psig Refrigerant: 230 psig (V46AS1 and V46AT1) 320 psig (others)
DIRECT ACTING, V46 SERIES
Part No. V46AA1 V46DA2 V46AB1 V46AC1 V46AC3 V46AD1 V46AD13C V46AE1 V46AR1 V46AS1 V46AS2 V46AS3C V46AT1 V46AT2 Connection Type FPT FPT FPT FPT FPT FPT FPT FPT 4 Hole, ASME Flange 4 Hole, ASME Flange 4 Hole, ASME Flange 4 Hole, ASME Flange 4 Hole, ASME Flange 4 Hole, ASME Flange Pipe Size (In.) 3/8 3/8 1/2 3/4 3/4 1 1 1 1/4 1 1/2 2 2 2 2 1/2 2 1/2
Opening Point Range (psig) 70 to 260 70 to 260 70 to 260 70 to 260 70 to 260 70 to 260 70 to 260 70 to 260 70 to 260 70 to 170 160 to 260 100 to 200 70 to 170 160 to 260
Pressure Connection (In.) 1/4 F Flare 1/4 F Flare 1/4 F Flare 1/4 F Flare 1/4 F Flare 1/4 F Flare 1/4 M Flare 1/4 F Flare 1/4 F Flare 1/4 M Flare 1/4 M Flare 1/4 FPT 1/4 M Flare 1/4 M Flare
Price 235.16 346.64 255.30 307.58 308.12 647.88 653.96 755.90 934.74 1345.24 1251.30 2158.82 1861.68 1861.68
948
PRESSURE
REVERSE ACTING, V46 SERIES
Part No. V46NB1 V46NB2 V46NC2 V46ND2 Connection Type FPT FPT FPT FPT Pipe Size (In.) 1/2 1/2 3/4 1 Opening Point Range (psig) 90 to 280 40 to 100 40 to 100 40 to 100 Pressure Connection (In.) 1/4 F Flare 1/4 F Flare 1/4 F Flare 1/4 F Flare Capillary Length (In.) 30 30 30 30 Price 282.70 280.62 319.64 670.44
THREE-WAY
V48 Series valves are designed specifically for condensing units cooled either by atmospheric or forced draft cooling towers. Maximum water pressure: 150 psig
V48AD2 Opening Point Range Normally Closed Side (psig) 85 to 110 145 to 190 85 to 110 145 to 190 Max. Bellows Overpressure (psig) 230 320 230 320
Pressure Connection (In.) 1/4 1/4 1/4 1/4 F F F F Flare Flare Flare Flare
V246 SERIES
The V246 2-way valves regulate water flow to control refrigerant head pressure in systems with water-cooled condensers. The V246 valves may be V246 used with standard non-corrosive or ammonia refrigerants. For applications where the coolant may be corrosive to the internal parts
Use with R410A refrigerant No close-fitting or sliding parts in water passages Accessible range spring Take-apart construction Pressure-balanced design Corrosion-resistant material for internal parts Maximum water temperature: 170F Maximum permissible water pressure: 150 psig Pressure connection: 1/4 MFL
DIRECT ACTING, MARITIME, V246 SERIES, TWO-WAY
V248 Series 3-way valves are designed specifically for condensing units cooled either by atmospheric or foced draft cooling towers. The V248 valves are used on single or multiple condenser hook-ups to the tower to provide the most economical and efficient use of the tower.
Part No. V248GD1001C V248GE1001C V248GL1001C V248GM1001C Connection Type FPT FPT Union Sweat Union Sweat
Use with R410A refrigerant Maximum water temperature: 170F Maximum permissible water pressure: 150 psig Pressure connection: 1/4 MFL
Opening Point Range (psig) 200 to 400 200 to 400 200 to 400 200 to 400
949
PRESSURE
WATER REGULATING, TEMPERATURE ACTUATED
TIMER
The V47 is a temperature actuated modulating valve that regulates the flow of water or glycol to maintain a desired temperature. Maximum bulb temperature: 20F above range Maximum water temperature: 170F Maximum water pressure: 150 psig Capillary: 6' nylon armor
Pipe Size (In.) 3/8 3/8 1/2 1/2 3/4 3/4 1 1 1 1/4 1 1/4 1 1/4 1 1/2 Opening Point Range (F) 115 to 180 75 to 135 115 to 180 75 to 135 115 to 180 75 to 135 75 to 135 115 to 180 75 to 135 115 to 180 160 to 230 115 to 180 Bulb Size (In.) 11/16 x 3 1/4 11/16 x 6 Cross Ambient 11/16 x 3 1/4 11/16 x 10 Cross Ambient 11/16 x 3 1/4 11/16 x 10 Cross Ambient 11/16 x 16 1/4 Cross Ambient 11/16 x 6 11/16 x 16 1/4 Cross Ambient 11/16 x 6 11/16 x 6 11/16 x 6 Price 612.72 625.44 652.38 665.18 698.72 710.42 1086.22 1052.82 1168.58 1135.24 1135.24 1325.12
V47AA1 Part No. V47AA1 V47AA3 V47AB3 V47AB5 V47AC3 V47AC6 V47AD1 V47AD2C V47AE1C V47AE2C V47AE3C V47AR2
DEFROST
TIME TIME
These timers are adjustable from one to six cycles per day. A minimum of four hours is required between successive operations. Defrost 804520 duration ranges from 4 to 110 minutes and is easily adjustable. Time initiation, time termination Contact rating: 40 amps resistive/pole
Part No. 804100 804120 804500 804520 804700 804720 Switch Type 2-NC/1-NO 2-NC/1-NO SPDT SPDT 2-NO/1-NC 2-NO/1-NC Voltage (Vac) 120 208/240 120 208/240 120 208/240 Price 210.24 210.24 210.24 210.24 267.28 210.24
These timers are adjustable from one to six cycles per day. A minimum of four hours is required between successive operations. Defrost duration ranges BTT4520 from 4 to 110 minutes in 2 minute increments and is easily adjustable. Time initiation, time termination Contact rating: 40 amps resistive/pole
Part No. BTT4100 BTT4120 BTT4500 BTT4520 Switch Type 2-NC/1-NO 2-NC/1-NO SPDT SPDT Voltage (Vac) 120 208/240 120 208/240 Price 167.32 167.32 167.32 167.32
TEMPERATURE, PRESSURE
PRESSURE
The 8420 Series defrost control is time-initiated with termination being regulated over a wide range of pressure settings. Cut-in pressures 824720 range from 36 to 110 psi. In addition to the pressure cut-in, the 8240 Series has backup mechanical defrost termination to protect against sensor failure. This timer allows settings from 4 to 110 minutes with two-minute increments. One to six defrost cycles may be set per day with a minimum of four hours between cycle initiation. Time initiation, temperature/pressure termination Contact rating: 40 amps resistive/pole
Part No. 824500 824520 824720 Switch Type SPDT SPDT 2-NO/1-NC Voltage (Vac) 120 208/240 208/240 Price 572.68 577.54 612.34
Backup mechanical defrost termination protects against sensor malfunction. 1 to 6 cycles per day. A minimum of 4 hours between successive defrost 814520 cycles. Adjustable from 4 to 110 minutes in 2 minute increments. Time initiation, temperature/pressure termination Contact rating: 40 amp resistive/pole
Part No. 814100 814120 814300 814320 814500 814520 814520B1
1
Bracket mount
950
TIMER
TEMPERATURE, PRESSURE, 4 POLE ELECTRONIC
Bracket mount control Contact rating: 55 amps resistive/pole Switch type: 3-NO/1-NC Voltage: 208/240 Vac Time initiation, temperature/pressure termination
Part No. 840820B Control Type Time Initiated, Temperature or Pressure Terminated Price 719.48
TEMPERATURE, PRESSURE
These timers are adjustable from one to six cycles per day. A minimum of four hours is required between successive operations. Defrost duration ranges BTP4100 from 4 to 110 minutes in 2 minute increments and is easily adjustable. Time initiation, temperature or pressure termination Contact rating: 40 amps resistive/pole
Part No. BTP4100 BTP4120 BTP4500 BTP4520 Switch Type 2-NC/1-NO 2-NC/1-NO SPDT SPDT Voltage (Vac) 120 208/240 120 208/240 Price 167.32 167.32 167.32 167.32
Real time clock. Initiate 15 minute manual defrost System status indicators 100 hours of power loss protection 914500 for both time and defrost schedule. Mechanism will fit in the standard Paragon enclosures; mechanism only versions are available Power comsumption: 6VA max Wires directly to 120V AC, 208V AC or 230V AC power sources without jumpers or switches Easy programming, easy set-up, set time, set defrost start and defrost end Display shows defrost start time and duration
Part No. 904500 Description Time Initiate/Time Terminate Defrost Timer with Metal Enclosure, SPST Time Initiate/Temperature, Pressure Terminate Defrost Timer with Metal Enclosure, SPDT Contact Ratings 30 amp (NC) Price 252.60
914500
261.52
DTAV40
DTAV40Q
320.76
Price 677.20
InterLink introduces the Smart Defrost Kit, a revolutionary way to save your customers a lot of money. A single, simple addition to the system give you the power to reduce your customers energy usage and operational costs, help them maintain the highest levels of product integrity and make their refrigeration systems SMART. Microprocessor control analyzes the system operation and initiates defrost only when the frost accumulation on the evaporator warrants. Reduced Operational Costs fewer defrosts result in lower energy usage and lower energy bills; reduces defrosts by up to 40% Quick Paybacks as quick as 6 months (up to an average of about 2 years). Enhanced Product Integrity by defrosting only when necessary, box temperatures stay more stable, protecting perishable inventory Easy to Install installs in about 30 minutes with no system evacuation required. Requires refrigeration system with electric defrost, 230V 50/60 defrost control voltage, electromechanical time clock with a contact closure reset input for defrost termination.
The DTAV40 defrost control automatically selects the appropriate voltage between 120VAC and 240VAC without the use of a dip switch/selector pins.
Reduce installation time Heavy-duty 40 Amp mechanical control 40 Amp resistive, 120-240 VAC 1 HP @ 120 VAC, 2 HP @ 240 VAC Operation temp: -40 to 104F 24-hour analog, captive trippers, 15 minute switching intervals Electrical Life: 50,000 Operations at full load
Part No. DTAV40 DTAV40M Description 40 Amp Auto Volt Defrost Control w/ Outdoor Enclosure 40 Amp Auto Volt Defrost Control, Mechanism Only Enclosure NEMA 3R Raintight Plastic None Price 228.42 201.46
951
TIMER
DEFROST
ERC2 SERIES
MULTI-CIRCUIT
A complete defrost program timer composed of just three basic components: frame, drive motor, and program modules. The drive motor module slides on to the end of the frame and is securely locked by a single captive hex bolt. Individual program modules slip into the frame and are secured by a spring-loaded clip bar. In the field any drive module or program module can be removed and replaced without disassembling the timer or disturbing program settings. Each program module has a 24-hour dial with time-of-day indication for initiation programming and a 2-hour dial for defrost duration control. Up to 12 operations per day are possible. The duration of defrost or the duration of backup defrost termination is 6 to 106 minutes. Integral solenoid termination permits termination of defrost upon closure of an external pilot device, such as a thermostat or pressure switch. Up to 24 program modules can be driven by one motor
DRIVE MODULE
The ERC-2 is a microprocessor-based controller designed to manage all of the temperature and defrost functions in a typical piece of commercial refrigeration equipment. By integrating these functions into one device, the ERC-2 can replace up to five different controls; the case thermostat, defrost timer, defrost termination switch, fan delay switch, and thermometer. The ERC-2 includes two NSF approved temperature sensors for the case and the evaporator. Also featured are four powerful relay outputs; one each for the compressor, fan, defrost and alarm. Selectable line voltage input power (120/208/240VAC at 50/60Hz) enable it to handle a wide range of equipment. Sensors may be extended to 100' with 18-22 gauge wire Temperature Setpoint: -40F to +60F Defrost Cycles: 1 to 8 per day or 1 every 48 hours Contact Rating: 16A Resistive (5A resistive alarm circuit) Case Dimensions: 4.40" W x 7.82" H x 3.80" D Display Module Dimensions: 2.75" W x 1.10" H x 1.38" D Agency Approvals: UL, NSF
Part No. ERC2212111 ERC2222111 1309007045 Description Universal Control, Integrated Display Universal Control, Remote Display NTC Sensor, 120" Price 372.28 376.08 31.90
Used with A87999 or A88099 frame modules and A876**, A877** circuit modules
A87820 Part No. A87800 A87820 Voltage (Vac) 120 208/240 Price 191.38 196.98
FRAME MODULE
Used with A87800 or A87820 drive module and A876** or A877** circuit modules.
A88099 Part No. A87999 A88099 Module Capacity 4 8 Price 214.98 256.78
Price 31.90
PROGRAM MODULE
A87700
Solenoid modules for temperature or pressure termination with remote switch Used with A87800 or A87820 drive modules and A87999 or A88099 frame modules
Solenoid No No No No Yes Yes Yes Yes Yes Yes Yes Yes Voltage 120 120 120 120 208/240 208/240 208/240 208/240 Price 209.82 209.82 209.82 209.82 244.02 244.02 244.02 244.02 256.54 225.78 256.54 256.54
Part No. A87699 B87699 D87699 E87699 A87700 B87700 D87700 E87700 A87720 B87720 D87720 E87720
Frequency Even Hour Even 1/2 Hour Odd Hour Odd 1/2 Hour Even Hour Even 1/2 Hour Odd Hour Odd 1/2 Hour Even Hour Even 1/2 Hour Odd Hour Odd 1/2 Hour
952
TIMER
DEFROST, FAN DELAY
24-hour timer with pump down, drain, or fan delay cycle. Defrost initiation: Adjustable from 18 cycles per day; minimum 3 hours between successive cycles
63220
Delay or pump down cycle: Adjustable for 030 minutes; 3 minute graduation; for stopping fans, reducing refrigerant pressure, or hot gas pump down cycle Defrost cycle: 345 minutes; 3 minute graduation Drain or fan delay cycle: Adjustable from 315 minutes; 3 minute graduation Contact rating: 10 amps resistive/pole
Switch Part No. 63200 63220 Type 2-NO/2-NC 2-NO/2-NC Supply Voltage (Vac) 120 208/240 Price 506.50 516.70
The FM/1 series modules are designed to be placed inside a machine control panel, circuit board, or other equipment. It offers up to 21A STUZ120 switching designed for control of heating, ventilating, air conditioning, refrigeration, lighting, security, circulating pumps, spas or any electrical load requiring 24-hour scheduling. Size: 2.36" x 2.36" x 1.25"
Part No. STUZ24 STUZ120 STUZ220 Voltage 24 120 240 Price 78.10 76.36 78.10
MIL72ASTUZ, GRASSLIN
ELECTROMECHANICAL
TRIPPERS
Usage 4000S, 4008, 4318 Cut-Out Pins (6) 632, 8000 Series Dial Pins (5) 4000S, 4200S Cut-Out Tripper RM Trippers
Time based control of lighting, ventilating, heating, cooling or other electrical loads in commercial and industrial applications. The MIL72 time MIL72ASTUZ240 switches are available with a 24-hour (STuZ) or 7-day (SWuZ) program dial with a SPDT switch. The MIL72A series is intended for surface mounting. The control is completely enclosed in a plastic housing and includes a terminal cover and sub-base for installation and hard wiring. All units are supplied with a clear plastic cover. Synchronous drive 21A SPDT switch Captive trippers with interval as low as 15 minutes Dimensions: 2.83" x 4.0" x 2.06"
Part No. MIL72ASTUZ120 MIL72ASTUZ240 Voltage 120 240 Price 90.88 92.60
7 DAY , GRASSLIN
GM40, GRASSLIN
Price 134.92
Different ON/OFF program each day of the week. True 7-day load control with minimum ON and minimum OFF times of 3 1/2 hours. Steel case: 12 1/2" H x 8 1/4" W x 4" D. Indoor type with toggle action drawbolt and locking feature. Knockouts - Combination 1/2"-3/4" nominal knockouts, two on back, one on each side and two on bottom. Also one 1" nominal on bottom center. Switch Rating - Each Pole 40 amp resistive, 120-480 VAC; 40 amp tungsten, inductive or 1000 VA pilot duty, 120-277 VAC; 2 HP (24 FLA) 120 VAC; 5 HP (28 FLA) 240 VAC single phase; 7-1/2 HP (28 FLA) 208 VAC three phase; 10 HP (28 FLA) 240 VAC three phase.
A universal, electromechanical clock which can automatically detect the voltage input without the use of dip switch or selector pins. The clock can operate at any voltage between 120 and 277 VAC. It selects input voltage automatically.
953
TIMER
ELECTROMECHANICAL
GMX, GRASSLIN
MECHANICAL
SPRING WOUND TERMINAL
The GMX Series Time Controls are universal, electromechanical time switches. They are a low cost alternative for applications that do not require more than 21A or 2HP @ 240VAC. The unit is mounted in a NEMA indoor or outdoor enclosure and is designed to control lighting, heating, air conditioning, pumps, motors, or other general purpose electrical circuits in residential, commercial, industrial and agricultural facilities. Contact Rating: SPDT, 21A Resistive @ 250VAC Voltage: 120 Vac
Part No. GMXST1120 Description Economy, 24 Hour Price 115.98
FM1D, GRASSLIN
The FM1D Series Timers are compact electronic 24 hour/7 day time switch module with heavy duty relay contacts for switching low or line voltage loads. Applicable for time of day control of pumps, fans, heaters, HVAC control circuits, lighting, machinery and many other types of commercial, industrial, and agricultural equipment. The FM1D Series features large keys with unique circular pattern for easy programming, an easy-to-read LCD display and capacitor backup to retain program memory during power outages. 8 FLA Amps @240 Vac Surface / din rail mount
Part No. FM1D20A120 FM1D50A12 FM1D50A24 Voltage 120 Vac 12 Vac/DC 24 Vac Nb of Set Points 20, Up to 140 Events/Week 50, Up to 350 Events/Week 50, Up to 350 Events/Week Price 210.48 248.80 248.80
These energy saving commercial timers use no electricity to operate. These timers are designed to replace any standard wall switch, single or multigang, and automatically limit the ON time of fans, lights, motors, heaters and other energy consuming loads. Time limits of 5, 15, 30 and 60 minutes and 2, 4, 6 and 12 hours are available. The hold feature allows the user to override the automatic shut-off function for extended use of the load as required. Rugged time-dial plate takes the abuse encountered in commercial environments. Time saving up front terminal connection with teeter type terminals and an easy press-on knob design ensure quick and easy installation. Switch Rating: Inductive: 20 Amp, 125 VAC, 50/60 Hz; 10 Amp, 250 VAC, 50/60 Hz; 10 Amp, 277 VAC, 50/60 Hz Tungsten: 7 Amp 125 VAC Motor: 1 HP 125 VAC 50/60 Hz; 2 HP 250 VAC 50/60Hz Caution: Do not use for sunlamps, sauna, etc...
Part No. FF15MC FF4H FF6H FF6HH FF12HC FF315M FF312HH Switch SPST SPST SPST SPST SPST SPDT SPDT Time Range 0 to 15 Minutes 0 to 4 Hours 0 to 6 Hours 0 to 6 Hours 0 to 12 Hours 0 to 15 Minutes 0 to 12 Hours Comment No Hold No Hold No Hold Hold No Hold No Hold Hold Price 49.14 57.98 57.98 57.98 57.98 74.48 87.84
DELAY TIMER
"DELAY ON MAKE"
Cycling pattern from 3% to 97% of total cycle duration Sealed enclosure handles dusty, ammonia rich or wash-down environments LED indicators provide constant operation feedback Manual On or Off override allows users to bypass cycling pattern when required Total cycle durations can be set from 30 seconds up to a maximum of 30 minutes, with ON/OFF durations from 1 second up to 29 minutes. Power input may be any standard 120 volt or 240 volt AC supply. Switch type: SPST Resiste amps: 20 amps Operating Temperature: 14 to 140F
Part No. CT2000 Time Range 30 seconds, 1, 3, 5, 10, 30 minutes, 1, 4 hours Price 249.06
General purpose "delay on make" timing function. Ideal for compressor staging and stagger-starting multiple units. Helps to reduce power surges in TDOM multiple compressor applications. When power is applied to the input, the time delay begins. After the time delay is complete, the load energizes and remains energized as long as power is applied. The control is reset by removing power during or after the time delay period. Voltage: 18240 Vac/Vdc Switch type: SPST, normally open
Part No. TDOM ICM103B Adjustment Type Dial Dip-Switch Delay Time (Sec.) 2600 11023 Price 17.70 26.60
954
TIMER
"DELAY ON BREAK" BYPASS
Helps to protect air conditioning, refrigeration and heat pump equipment from damage which may be caused by the rapid short-cycling of compressors. Upon application of power, the load is energized. When the thermostat or other switch opens or there is a loss of power, the load is de-energized and the delay period begins. The compressor will not start again during the delay period. Anti short-cycle Off delay on break Contact rating: 1.5 amps
Input Part No. TDOB Voltage (Vac) 18240 Adjustment Type Dial Delay Time (Sec.) 2600 Price 17.70
An adjustable, multi-voltage bypass timer that allows the temporary bypass of a control or device during start-up. At the end of the delay period the control is returned to the circuit.
Delay Part No. 32395 Time 6 Sec.-8 Min. Adjustment Type Dial Input (Vac) 19-240 Max. Amps 1 Price 55.20
BYPASS
Designed to bypass a control or device during startup. Typically used to bypass a low pressure switch or an oil pressure switch upon startup. Helps to eliminate nuisance lockouts. With power applied to the input, the load energizes immediately and remains energized for the length of the time delay, regardless of the state of the switch being bypassed. At the end of the time delay, the condition of the load is determined by the state of that switch. On delay interval timer Normally closed "delay on make" Ideal for low ambient startups Integral component for "winter start" kits Contact rating: 1 amp
Input Part No. ICM175B Voltage (Vac) 18240 Adjustment Type Dial Delay Time (Sec.) 101000 Price 23.90
UNIVERSAL
Model 32391 is the most popular timer in the industry Maximum amps: 1 (6 for 32397)
32391 Type Part No. 32391 32392 32397 Delay On Make On Make On Make Delay Time 6 Sec.-8 Min. 6 Sec.-5 Min. 11000 Sec. Adjustment Type Dial Dial Dial Input (Vac) 19-240 19-240 24 Price 26.86 26.86 100.24
20 time ranges and 10 timing functions Time delays up to 600 hours P1A timing function: Cycle 2 (power start, ON first) - Cycle 1(power start, OFF first) - Interval 1 (power start) - On Delay 1 (power start) P2A timing function: Cycle Mode (signal start, ON First) - On Delay 2 (signal start) - Signal Off Delay 1 (signal start) - Signal On/Off Delay 1 (signal start) - Cycle 2 (signal start) - One Shot 2 (signal start) High repeat accuracy of 0.2% ON and timing OUT LED indicators 2 form C delayed output contacts 10A Contact rating
Part No. RTEP1AD24 RTEP1AF20 RTEP2AD24 RTEP2AF20 Input Voltage 24 Vac/Vdc 120-240 Vac 24 Vac/Vdc 120-240 Vac Timer Terminal Type Type Power On Trigger 8 Pin (Maintained Start Signal) Plug-In Power On Trigger (Maintained Start Signal) Dry Contact Trigger (Momentary Start Signal) Dry Contact Trigger (Momentary Start Signal) 8 Pin Plug-In 11 Pin Plug-In 11 Pin Plug-In Price 130.00 130.00 130.00 140.00
UNIVERSAL, DIPSWITCH
955
TIMER
RELAY , SWITCHING
SOCKET DIN MOUNT SCREW TYPE FAN DELAY/POST PURGE
SR3P06
SPDT, DPDT, or 3PDT pure silver contacts Worldwide approvals on octal (8-pin and 11-pin) models: UL, CSA, TUV, CE Options include check button for test operation and indicator light
Description Socket for 8 Pin Timers (RTEP , RR1PA, RR2P , GE1A, GT5P , GT3) Socket for 11 Pin Timers (RTEP , RR3PA, GT3) Price 12.00 16.00
32377, 32378 and 32379 will perform either on-delay or off-delay functions. On-delay is especially useful for controlling unloader valves. Off-delay 32393 can be used for fan off-delay, pump down systems or post purge applications.The off-delay may also serve an anti-bounce function as a pump flutter bypass switch.
Type Part No. Delay 32377 32379 32393 Delay Time Adjustment Type Dial Dial Fixed Input (Vac) 24 240 24 Max. Amps 6 10 1 Price 97.76 145.04 41.54
Controls the circulating fan in heat pump, air conditioning and forced air systems. Off delay timing function continues to run the fan at the end of the heating/cooling cycle. A one second interrogation delay is provided to avoid nuisance trips due to thermostat bounce or tampering. Contact rating: 1 amp
Input Part No. ICM253 Voltage (Vac) 1830 Adjustment Type Dial Delay Time (Sec.) 12390 Price 32.64
Integrate control of combustion blower and circulating fan operations in a gas warm air appliance. A single circuit board providing combustion air blower control, two speed circulating air blower control, limit circuit inputs, thermostat wiring terminations. Central appliance wiring point simplifies appliance assembly and service. Fixed or field-adjustable heat fan on delay; field adjustable heat fan off delay
Part No. ST9120U1011 Description Furnace Timer, Adjustable Settings, Universal Price 237.18
Lockout delay prevents rapid cycling of compensated resistor type wall thermostats Brownout protection prevents startup when voltage is below normal conditions Delay on break
CONTROLS & ELECTRICAL ACCESSORIES
Part No. 32382 Time Delay (Min.) 5 Input Voltage 24 Max. Amps 1 Price 50.84
Integrate control of combustion burner and circulating fan operations in an oil furnace. A single circuit board providing combustion air blower control, two speed circulating air blower control, oil primary control, limit circuit inputs, thermostat wiring terminations and a central appliance wiring point for an oil fixed furnace Central appliance wiring point simplifies appliance assembly and service. Fixed or field-adjustable heat fan on delay; field adjustable heat fan off delay
Part No. ST9103A1002 Description Furnace Timer, Adjustable Off Delay Price 191.16
Solid state replacement for Ranco type E-15 Reliable thermistor-type sensor is less susceptible to breakage, easier to mount Replaces faulty bulb-type sensors 24, 120 or 240 Vac operation 10 minute defrost interval Pin-selectable interval time (30/45/90)
Part No. ICM315 Description Ranco E15 Type Board Price 148.36
956
TIMER
UNIVERSAL INTEGRATED FURNACE TIMER HEAT PUMP DEFROST 621 TYPE
Can be used with conventional thermostats as well as the EnviraCOM enabled VisionPRO IAQ and FocusPRO. The S9200U1000 Universal Integrated Furnace Control is intended for residential natural or liquid propane fueled furnaces only. The S9200U1000 EnviraCOM communications capability allows its use in twinning applications and enables communication with local and remote diagnostic devices such as the QuickLook hand held device (QuickLook 72), EnviraLNK web-based application and the W8735D Telephone Access Module (TAM). Main burner ignition using a 120V hot surface igniter. Flame rectification circuit to monitor flame presence. Monitoring of system pressure switch, high temperature limit, and rollout functions.
Part No. S9200U1000 Description Universal Hot Surface Ignition Integrated Furnace Control Price 231.22
Replacement for OEM Type 621 control. Pin selectable defrost interval. Time/temperature termination 50/60 Hz
Part No. 32572 Defrost Interval (Min.) 30, 60, 90 Defrost Duration (Min.) 10, Fixed Voltage 1831 Price 58.92
DOMESTIC
DEFROST TIMER KITS
These traditional Paragon defrost timer kits have been designed and engineered specifically for the replacement timer market.
Defrost Frequency (Hours) 8 6 Defrost Time (Minutes) 18 28
Part No.
B76900 F76900
These heavy duty 15 amp Paragon timers are being used by the O.E.M. manufacturers today. They will replace both the older classic design timers and the new O.E.M. versions.
Low voltage time/temperature defrost controller for heat pumps. Replaces most time/temperature 621 type controls
Part No. ST74A1053 Off Time (Min.) 50/70/90 On Time 10 Fixed Price 75.88 EDT10 Voltage (Vac) 120 208/240 120 208/240
UNIVERSAL, RESIDENTIAL
Direct replacement for OEM Type 621 Time/temperature defrost 24 Vac operation (1830 Vac) 10 minute defrost interval Pin-selectable interval time (30/60/90) Replaces Arcoaire part number 1052757
Part No. ICM300 Description Time Temperature Defrost Board Price 42.30
The "EDT" has a two dial adjustment configuration that allows for the setting of any defrost frequency from 4 to 12 hours and any defrost time from 10 to 35 minutes.
957
The MR Series temperature controls are designed for hot gas or electric heat defrost in both refrigeration and freezer units. Either time or temperature based defrost termination may be selected. The MR Series incorporates control functions such as compressor control, defrost management, fan management, and alarm management.
Part No. MR4PMUHV12C
Time initiation, time, temperature termination Combined functionality of an electromechanical thermostat, mechanical clock, defrost termination device, and temperature readout device 2 sensors included: 6' leads Contact rating: (compressor, heater relays), 12 F.L. Amp @ 240 Vac Temperature/defrost
Price 586.18
VALVE, COMBINATION
CONTINUOUS PILOT
Provides complete control of continuous pilot gas-fired central furnaces and boilers. Includes pilot flow adjustment screw
VS820A1047 Size (In.) Part No. V400A1095 V800A1070 V800A1088 V800A1476 VS820A1047 VS820A1054 Application 120V, Use with 30mV Thermocouple 24V, Use with 30mV Thermocouple 24V, Use with 30mV Thermocouple 24V, Use with 30mV Thermocouple Self Powered, Use with 750mV Thermopile Self Powered, Use with 750mV Thermopile Inlet 3/4 1/2 3/4 1/2 1/2 3/4 Outlet 3/4 3/4 3/4 3/4 3/4 3/4
Easy to install, adjust and service Includes reducer bushings to adapt line size
Combination gas control for use in 120 Vac, gasfired, standing pilot appliances with capacities from 30 to 300 cfh. Control includes safety shutoff, manual valve, two automatic operators, pressure regulator and pilot adjustment
CONTROLS & ELECTRICAL ACCESSORIES
Solenoid operated first automatic valve opens on thermostat call for heat; closes when call for heat ends. Diaphragm-operated second automatic valve opens under control of regulator; closes if gas or power supply is interrupted. Standard regulator Combination dual automatic valve Power: 120 Vac
Includes LP Conversion Kit Price 376.60
Size (In.) Part No. VR4300A4502 Inlet 3/4 Outlet 3/4 Capacity (cfh) 200 Type Gas Natural
VR8200A2124
Combination gas controls for use in 24 Vac, gasfired, standing pilot appliances with capacities from 20 to 200 cfh. Controls include manual valve, two automatic operators, servo pressure regulator and pilot adjustment
Capacity (cfh) 130 130 M130 Type Gas Natural Natural Natural Type Regulator Standard Standard Slow Open
Size (In.) Part No. VR8200A2124 VR8200A2132 VR8200H1251 Inlet 1/2 1/2 1/2 Outlet 1/2 1/2 1/2 Includes LP Conversion Kit Thermocouple (36") LP Conversion Kit LP Conversion Kit Price 181.78 168.16 214.86
958
VR8300A4508
Combination gas controls for use in 24 Vac, gas-fired, standing pilot appliances with capacities from 30 to 300 cfh. Controls include safety shutoff, manual valve, two automatic operators, pressure regulator and pilot adjustment
Capacity (cfh) 190 190 200 200 200 Type Gas Natural Natural Natural Natural Natural 3/4 3/4 3/4 3/4 3/4 Outlet
Conversion Kit Supplied Yes Yes Yes Yes Price 195.22 208.64 213.40 232.76 334.26
CONTINUOUS PILOT
36C03333
Ideal for general purpose replacement, these 36C combination gas valves are furnished with natural to LP conversion kit, reducer bushings and self-adhesive label with pilot lighting instructions. Reducer bushings provided
Capacity Size (In.) AGA Outlet 3/4 3/4 3/4 3/4 3/4 3/4 (BTUH) 230,000 230,000 280,000 280,000 230,000 280,000 Voltage (Vac) 24 24 24 24 750mV 750mV
Valve may be mounted in any position, except upside down Both main valve seat and line-interrupter seal with line pressure, assuring positive gas seal-off Natural gas
LP Conversion Kit No Yes No Yes Yes Yes Side Taps No Yes No Yes Yes Yes Price 158.66 168.52 181.92 213.38 242.60 273.32
Model 36C53 complete gas control combines into a single compact package that functions as a 3-position gas cock, pressure regulator, 100% shut-off automated pilot and main operator. This model features a slow opening main valve that provides a softer ignition.
Size (In.) Part No. 36C53418 Inlet 3/4 Outlet 3/4
Usage: natural gas regulator setting 3.5" WC Order LP conversion set separately ECO terminal included
700402
These valves feature a manual valve (gas cock), an automatic pilot safety valve, inlet/outlet screens, pilot outlet, pilot gas filter and pilot adjustment key. The automatic pilot safety valve is separate from the gas cock and provides gas shutoff in case of pilot outage. The 700 Series 24 volt Uni-Kits have a pressure regulator installed that is set for natural gas (3.5" W.C.).
Size (FPT In.) Inlet 1/2 3/4 3/4 1 Outlet 3/4 3/4 3/4 1 Side Straight-Thru Straight-Thru Straight-Thru Straight-Thru
To convert to L.P. gas, a regulator cover plate is included. Simply remove pressure regulator and install the regular cover plate. Note: Valves can be mounted in any position except upside down. Reducer bushings included
Pressure Regulator (In. W.C.) Uni-Kit Uni-Kit 3.5, Natural 3.5, Natural Capacity (BTUH) 240,000 300,000 300,000 600,000 Price 138.68 162.12 430.28 571.20
425.98
959
700452
The 700 line voltage combination gas controls are available in 120 Vac models. These controls combine into one compact valve: a manual gas cock, automatic pilot safety valve and a silent line voltage operator. Regulated and nonregulated models are available. Standard features include: pilot outlet, pilot gas filter
Size (FPT In.) Inlet 1/2 3/4 1
2
and pilot adjusting key. The automatic pilot valve is separate from the gas cock and provides gas shutoff in case of pilot outage. Note: Valves can be mounted in any position except upside down.
Pressure Regulator Capacity (BTUH) 240,000 300,000 600,000 Price 251.58 251.58 791.64 (In. W.C.) 3.5, Natural 3.5, Natural 3.5, Natural
Diaphragm/solenoid valves are single function, diaphragm types and are excellent replacements for solenoid gas valves. Standard features include: pilot outlet, pilot gas filter and pilot adjustment key.
Size (FPT In.) Part No. 700422 Inlet 1/2 Outlet 3/4 Side 1/2
Note: Valves can be mounted in any position except upside down. These valves do not have a safety magnet. Power supply: 24 Vac
Pressure Regulator (In. W.C.) 3.5, Natural Capacity (BTUH) 240,000 Price 244.96
700502
The 700 millivolt gas valves are wall thermostat actuated combination gas valves. These controls combine a manual gas cock, automatic pilot safety valve and a millivolt operator. The automatic pilot safety is separate from the gas cock and provides gas shutoff in case of pilot outage. Standard features
Size (FPT In.) Inlet 1/2 3/4 Outlet 1/2 3/4 Side 1/2 Straight-Thru
include: pilot outlet, pilot gas filter and pilot adjusting key. Note: Valves can be mounted in any position except upside down. Power supply: 250750 mV Reducer bushings included
Pressure Regulator (In. W.C.) 3.5, Natural 3.5, Natural Capacity (BTUH) 100,000 300,000 Price 183.76 185.14
The 720 Series gas controls are designed for a wide variety of heating applications and can be used to replace most constant pilot valves, including 720402 dual valve (six function) models. The 720 Series constant pilot gas valve is a six function valve incorporating a manual valve, safety shutoff magnet, dual automatic valves, main gas regulator, and pilot adjustment. Uni-Kits are factoryset at 3.5" W.C. for natural gas, but can be converted to LP by installing the regulator conversion kit included.
Part No. 7204001 7204021 7204061 7204722 7204742
1
The 720 Series feature an integral manual selector used to select from the 4 gas flow positionsoff, on, pilot and "set". The "set" position provides pilot only gas flow during magnet energizing and lock up. Built-in stops serve to prevent accidental setting to the off position. Regulates to 15,000 BTU minimum, 200,000 BTU maximum, for natural gas Capacity: 150,000 BTUH Reducer bushings included
960
710502
The 710 low capacity gas heating valves are designed for recreational vehicles and other applications with limited space. All models include a manual valve (gas cock), automatic pilot safety valve, pilot outlet, pilot gas filter and pilot adjusting key.
Type Pressure Regulator (In W.C.) 3.5, Natural None 3.5, Natural Operation 24 Volt Millivolt Millivolt
Note: The control can be mounted in any position except upside down and all models have 3-position outlets. Supplied with pipe bushings
Typical Application Wall Furnaces Space Heaters/Replace B67 Space Heaters/Replace B67 Price 225.26 301.94 248.22
VR8204A2076
Combination gas controls for use in 24 Vac, gas-fired, intermittent pilot appliances with capacities from 20 to 200 cfh. Controls include manual valve, two automatic operators, servo pressure regulator and pilot adjustment
Size (In.) Pressure Regulating Outlet 1/2 1/2 1/2 1/2 Setting (in. wc.) 3.5 3.5 (Full Rate) 0.5 (Step Setting) 3.5 3.5 Inlet 1/2 1/2 1/2 1/2
Combination dual automatic valve Includes reducer bushings, natural to LP conversion kit Power: 24 Vac
VR8304M3509
Combination gas control for use in 24 Vac, gas-fired, intermittent pilot appliances with capacities from 30 to 415 cfh. Controls include safety shutoff, manual valve, two automatic operators, pressure regulator and pilot adjustment
Capacity Outlet 3/4 3/4 3/4 3/4 3/4 (cfh) 270 300 300 Type Gas Natural Natural LP Natural Natural
Size (In.) Part No. VR8304M3509 VR8304M4507 VR8304P4330 VR8304P4504 VR8304Q4511 Inlet 1/2 3/4 3/4 3/4 3/4
Type Regulator Standard Standard Step Open Step Open Slow Open
Conversion Kit Supplied Yes Yes Yes Price 255.88 249.26 286.30 399.56 329.82
Controls include safety shutoff, manual valve, two automatic operators, pressure regulator and pilot adjustment. Use with S86F,H; S860D; S8600F,H; S8610 and S90A,B Control Modules. Solenoid operated first automatic valve opens on thermostat call for heat; closes when call for heat ends. Diaphragm-operated second automatic valve opens under control of regulator; closes if gas or power supply is interrupted.
Size (In.) Part No. VR4304M4519 Inlet 3/4 Outlet 3/4 Capacity (cfh) 415
Standard and slow opening natural gas models include natural to LP gas conversion kit; LP to natural gas conversion kit also available. All adjustments, wiring connections and pilot outlet are accessible from top of control. Adjustable servo regulator effectively maintains almost constant gas output pressure under wide fluctuations in gas supply pressure. Compatible with ECO connector. ON-OFF lighting sequence.
961
Universal electronic ignition combination gas control for use with direct spark ignition, hot surface ignition or intermittent pilot ignition in 24 Vac, gas-fired appliances with capacities from 30 to 415 cfh. Control includes manual valve, two automatic operators, servo pressure regulator, pilot adjustment, pilot plug and ignition adapter
Size (In.) Part No. VR8345M4302 Inlet 3/4 Outlet 3/4 Capacity (cfh) 300
Replaces virtually any IP, HSI, or DSI gas control For use with natural or manufactured gas or LP gas. Includes converter kit to adapt from natural to LP gas Includes reducer bushings Power: 24 Vac
Price 225.10
The Intermittent Hot Surface Pilot Ignition SmartValve System Controls provide easy field replacement of a wide range of SV9500, SV9501, SV9502 and SV9602 SmartValve System models. These controls provide intermittent pilot gas ignition sequencing, pilot flame sensing, and both pilot and main gas control functions in a single control. They are directly compatible with the
Part No. SV9501M2528 SV9501M8129 Size (In.) Inlet Outlet 1/2 NPT 1/2 NPT 1/2 NPT 1/2 NPT Capacity (cfh) 200 200
Q3450 or Q3480 Intermittent Pilot burners used with the original controls on the appliance. Suitable for a wide range of gas-fired appliances including residential furnaces, roof-top furnaces, residential boilers, unit heaters, infrared heaters, space heaters and commercial cooking units. Ignition sequence includes timed trial for ignition. SV9501M8129 includes 395454 extension harness and 393691 NAT to LP conversion kit
Type Gas Natural Natural Type Regulator Fast Open Standard Price 406.72 406.72
The SV9601 SmartValve System Controls combines gas flow control and electronic intermittent pilot sequencing functions into a single unit. This system is suitable for application in a wide range of gas-fired appliances including furnaces, rooftop furnaces, boilers, unit heaters, infrared heaters, space heaters, water heaters, decorative appliances, and commercial cooking units.
CONTROLS & ELECTRICAL ACCESSORIES
Part No. SV9601M4571 Size (In.) Inlet Outlet 3/4 NPT 3/4 NPT Capacity (cfh) 415
Suitable for a wide range of gas-fired appliances including residential furnaces, roof-top furnaces, residential boilers, unit heaters, infrared heaters, space heaters and commercial cooking units. Ignition sequence includes timed trial for ignition. Includes: Two 3/4" x 1/2" reducer bushings and an LP conversion kit.
Price 478.46
The SV9641 SmartValve ignition system control provides all gas ignition safety functions by controlling gas flow, ignition source, and a 120 Vac or 240 Vac combustion air blower. It also monitors the appliance airflow proving switch and limit string to assure proper appliance operation, and provides prepurge, postpurge, and timed trial for pilot ignition with 100 percent shutoff and continuous retry. A diagnostic LED indicates system status.
Size (In.) Outlet Inlet 1/2 NPT 1/2 NPT Capacity (cfh) 200
Communicates directly with an electronic fan timer (ST9160 Electronic Fan Timer for single stage applications; ST9162 Electronic Fan Timer for two-stage applications) in typical forced warm air furnace applications. Interfaces with the 208907 Suitable for a wide range of fan-assisted combustion gas-fired appliances including furnaces, rooftop furnaces, boilers, unit heaters, infrared heaters, water heaters and commercial cooking appliances. OEM applications for ICP, Mestek and Slant/Fin.
Type Regulator Standard Conversion Kit Supplied Yes
Price 487.50
962
700056
These 700 Series ignition gas valves are designed for intermittent pilot, direct spark or hot surface usage, and include necessary parts to adapt to these applications. These valves incorporate a manual valve, pilot valve, and a main gas pressure regulator.
Bushings included Has slow opening feature for soft ignition. Can be field removed.
720079
The 720 Series gas controls are designed for electronic ignition applications: hot surface, direct spark and intermittent pilot. The 720 Series incorporates a manual valve, 2 dual automatic valves and a main gas pressure regulator. Uni-Kits are factory-set at 3.5"
Inlet 1/2 1/2 1/2 Size (FPT In.) Outlet 1/2 3/4 3/4
W.C. for natural gas, but can be converted to LP by installing the regulator conversion kit included. Power supply: 24 Vac Uni-Kit regulator conversion included
Cycle pilot gas valves are equipped with redundant pilot solenoid main gas regulator, integral gas pressure switch and electrical connection on the gas valve for mercury flame sensor connection.
36C84912 Part No. 36C84912 36C84913 36C84921 36C84923 36C84926 36C84945 Electrical Connection 4 Spade Terminals, 1/4", CCLS 3 Spade Terminals, CCS, 5 30" Leads 4 Spade Terminals, 1/4", CCLS 4 Spade Terminals, 1/4", CCLS Edge Connector to P .C. Board 3 Spade Terminals, 1 PIN Terminal
Connections: 3/4" x 3/4" AGA Capacity: 280,000 BTUH Regulator setting: 3.5" W.C Natural gas Reducer bushing kit included
LP Kit Included Included Included Natural Only Natural Only Included Price 473.76
Compact multifunction valve designed to meet the requirements for use with all types of intermittent ignition systems (proven pilot, direct spark ignition and hot surface ignition).
Part No. 36C94303 Electrical Connection 5 Spade
Connections: 1/2" x 3/4" Regulator adjustment: 2.5 to 5.0" W.C natural gas, 7.5 to 12.0" W.C L.P. Coil voltage: 24 Vac
Side Taps No Price 250.68
Usage Proven Pilot with Pressure Switch, Slow Open, Nat only
Please contact your local United Refrigeration Branch or our Customer Service Center for pricing.
CONTROLS & ELECTRICAL ACCESSORIES
963
Designed for direct spark ignition and hot surface ignition system applications. This valve is equipped with redundant and main solenoid valves that control gas flow to the main burners, a pressure regulator and a two-position on/off switch for regulation and electrical shut-off of the solenoid valves. Regulator calibrated to 3.5 0.3" WC @ 100,000 BTUH. Natural gas/LP conversion kit Inlet/outlet reducer bushings (1/2 NPT x 3/8 NPT)
Part No. 36J24214 Usage Proven Pilot, HS/DS, Slow Open, Low Voltage, Nat Gas Inlet Size (In.) 1/2 Outlet Size (In.) 1/2 Capacity AGA (BTUH) 140,000 Price 292.46
Designed for use on automatic spark ignition systems. Fast open operation High/Low feature to permit two different rates of input to the main burner Natural/LP; conversion kit included Regulator settings : LO 1.0" W.C.(adj 1 to 3.5"), HI 3.5" W.C.(adj 2.5 to 5") Bushing kit included
Part No. 36H64463 Inlet Size (In.) 3/4 Outlet Size (In.) 3/4 Capacity CSA (BTUH) 300,000 Coil Voltage (Vac) 24 Price 292.46
Combination gas controls for use with hot surface/direct spark systems in 24 Vac, gas-fired appliances with capacities from 20 to 200 cfh. Controls include manual valve, two automatic operators and servo pressure regulator Combination dual automatic valve Includes reducer bushings, natural to LP conversion kit
Size (In.) Part No. VR8205A2024 Inlet 1/2 Outlet 1/2 Capacity (cfh) 150 Type Gas Natural Type Regulator Standard Price 240.36
Combination gas control for use with hot surface/direct spark systems in 24 Vac, gas-fired appliances with capacities from 30 to 415 cfh. Controls include manual valve, two automatic operators, and pressure regulator Combination dual automatic valve Includes bushing, natural to LP conversion
Part No. VR8305M3506 VR8305Q4500 Size (In.) Inlet Outlet 1/2 3/4 3/4 3/4 Pressure Regulator (In. W.C.) 3.5 1.7 Low, 3.5 High Price 245.92 338.34
COMMERCIAL
Provides electrically operated pilot solenoid which is controlled by room thermostat. Main valve is energized by a mechanical flame sensor or electronic ignition/flame detecting module. For hot surface, direct spark Usage: natural gas LP conversion kit order separately, provide for 100% lockout Capacity (BTU/H): 300,000 (1" PD, .64 specific gravity 1,000 BTU/Cu. Ft.) Pipe size: 3/4" x 3/4" Coil voltage: 24 Vac
Part No. 36H32423 36H33412 36H65401 Opening Characteristic Fast Slow Slow Stages 1 1 2 Price 217.52 230.64 301.56
Suitable for use on atmospheric boilers, commercial water heaters, and rooftop heaters. Solenoid-operated valves for use V4943 with natural gas (and LP gas for V4943A only) Valve body of die-cast aluminum with a straight through pattern V4943 for use with line voltage, on/off controllers V4944 for use with line voltage, dual stage controllers Pressure regulator: 3.5 w.c. Dimensions: 6 9/16" H x 6" W x 6" D Pipe size: 1" Voltage: 120 Vac
Capacity Part No. V4943A1011 V4944B1018 V4944N1011 Description On/Off Diaphragm Valve Two Stage Pressure Regulating Two Stage Pressure Regulating (cfh) 1000 300 to 1000 300 to 1000 Valve Opening Time (Sec) 6 3 to 25 3 to 25 6 Price 305.24 361.14 434.16 421.80
964
GAS PILOT
UNIVERSAL PILOT BURNER
Bleed gas diaphragm valves feature: automatic pilot valve, bleed gas operator, inlet and outlet screens, manual "gas cock" valve, pilot adjusting key, pilot gas filter and pressure regulator. Regulated models offer the additional feature of "straight line" pressure regulation, allowing application of the 700 diaphragm gas valves to a wide range of capacity requirements without regulator readjustment. Minimum application for regulated models is 10% of capacity shown. These valves are most commonly used on commercial water heating equipment in conjunction with the 1352 (CWH-3) bleed gas temperature controllers. Valve has as slow opening feature Reducer bushings included
Part No. 700804 Size (In.) Pressure Regulator Inlet Outlet (In. W.C.) 3/4 3/4 3.5, Natural Capacity (BTUH) 305,000 Price 264.84
Q314U1001
Q345U1005
Q3451U1000
Q348U1009
With four pilots, contractors can replace over 100 different models. The Universal Pilot offers adjustable mounting options, flexible hood orientations and the accessories needed for replacement. Natural or LP gas. Includes a universal mounting bracket
Part No. Q314U1001 Description Standing Pilot Burner. Non-Primary Aeration, BCR-18, BBR-10, CAR-12, CAR-13, BBR-8 Orifices, Standard and low BTU hoods, Adjustable Tip Style Target Style Pilot Burner. Non-Primary Aeration, BCR-20, BCR-18, BBR-12, BBR-11 Orifices, Adjustable Tip Style Target Style Pilot Burner with Integral Ignition Wire. Non-Primary Aeration, BCR-20, BCR-18, BBR-12, BBR-11, BCR-10 Orifices, Adjustable Tip Style, 36" and 55" igniter lead lengths Intermittent Batwing Style Pilot Burner. Primary Aeration, NE22, KF24, A26, KR14 Orifices Price 88.28
Q345U1005
113.00
144.44
710205 Pressure Regulator (In. W.C.) None 3.5, Natural Capillary Length (Ft.) 3 3 Typical Application RV's Wall Furnace
113.14
The Y99 valve connection reducer kit allows easy conversion of any valve or regulator pipe connections in the field. Y99AP1 The kit does not alter the overall face-to-face dimensions. The kit contains an anti-galling compound, wrench, and four male and female bushings.
Part No. Y99AP1 Y99AP2 Description 1/2" MPT x 3/8" FPT Bushing 3/4" MPT x 1/2" FPT Bushing Price 81.20 78.10
Non primary-aerated, insert orifice-type pilot burner for main burner ignition with Q340 or Q390 thermocouple for pilotstat safety control operation. Use with Q313 for 750 mV powerpile application Tip Styles:
1751004
The 1751 Series add-on pressure regulator kits are available for the indicated valves. 700 Series hydraulic cannot be converted
Valve Usage (Series) 700, 710 700, 710 7100, 720 700, 710
965
Non primary-aerated combination pilot burner and igniter. Used with the S86, S860, S8610 or S8670 in intermittent pilot systems.
Q345A1305 Part No. Q345A1305 Q345A1313 Q345A1321 Tip Style B A C Gas Natural Natural Natural Bracket End End End Price 55.62 59.10 57.90
Primary-aerated, spud orifice-type pilotburner for main burner ignition with Q340 or Q390 thermocouple for pilotstat safety control operation.
The J Series BASO universal replacement pilot burners are supplied in three models. Mounting brackets on all four sides of each burner permit adaptation to almost any application.
J999MYA2
Gas Natural, LP
Bracket End
Price 62.70
PILOT BURNER
Q15 MISER
Replaces pilot burner and sensor probe on specific OEM units in Q15 miser gas control system.
Q90BB1 Part No. Q90AA1C Q90BB1 Q90CC1 Q90DD1 Code J989EKW J996DKW J986HXW J993HHW OEM Lennox Carrier Reznor Reznor Price 113.62 113.62 115.90 118.02
9B PILOT, UNIVERSAL
J992MDA2
Universal replacement models replace J12, J13 pilots. "A" dimension: .850"
The 4-ported Universal 9B Pilot Uni-Kit is designed to replace all obsolete Model 9B pilot variations. The kit includes fittings for 1/4" tubing and an adaptor for fittings to adapt to 3/16" tubing. Each kit comes with a natural gas orifice installed and includes a separate L.P. gas orifice. The 1800-100 is hooded, aerated, constant burning pilot for main burner ignition.
Part No. 1800100 Description Universal 9B Replacement Pilot Price 78.66
Part No. J991MDA2 J992MDA2 J993MDA2 J994MDA2 J995MDA2 J996MDA2 J997MDA2 J998MDA2 J999MDA2
Figure 1 2 3 4 5 6 7 8 9
Price 61.48 60.02 61.48 65.06 61.12 61.80 61.48 59.04 57.34
966
PILOT TUBING
Designed to replace those hard-to-find ITT-General PG9 type pilots. Each Uni-Kit comes with a natural gas orifice installed and a separate L.P. gas 1820019 orifice. A special 1/4" tubing adaptor is provided to allow use of original tubing with nut and ball sleeve. These 1820 Pilot Uni-Kits are aerated type pilots, combining the best feature of an incinerator type pilot and a target type pilot. Includes thermopile
Part No. 1820009 1820019 Flame Pattern 90 Right 90 Left Replaces P/N PG9A42JTL020 PG9A41JTL020 Price 75.60 75.60
Price 30.18
INCINERATOR TARGET
Designed to be used with all Uni-Line and competitive thermocouples, these kits include an adaptor that converts a threaded thermocouple/thermopile 1830001 model 2CH to a snap-in thermocouple type, model 2C. These are aerated type pilots, combining the best feature of an incinerator type pilot and a target type pilot. These pilots have non-linting characteristics, and no air shutters or supplementary shields requiring assembly or adjustment.
Part No. 1830001 1830005 1830110 1830111 1830112 Replaces P/N 2CH-6 4CH-6 2CH-1 2CHL-1 2CHR-1 Flame Pattern Standard 3-Way Standard 25 Left 25 Right Price 53.88 43.46 52.38 52.38 53.88
Description Pilot Tubing, Aluminum, 1/4" OD x 50' Pilot Tubing, Aluminum, 1/8" OD x 5' Pilot Tubing Nut, 1/4"
THERMOCOUPLE
UNIVERSAL
Replaces a lot of older style Carrier, Payne and Bryant models. Convertible from 3 wires to 2 wires. Eletrical rating: 30 Vac, 60 Hz, 1.0 Amp
Part No. PS730A Replaces P/N LH680005, LH33JZ053 Type Gas Natural Price 93.90
GAS ORIFICE
Q390A1046
For use on gas-fired heating systems as an alternative to Q340 with Universal two-piece adapter. Average operating life of 57 years
Lead Length (In.) 24 30 36 Price 9.60 10.14 10.70
Part No. Q390A1046 Q390A1053 Q390A1061 10021 Pilot Part No. 10021 10114 Usage 2C, 2CH 2C, 2CH Type Gas Natural L.P . Tube Diameter (In.) 1/4 1/4 Orifice Size (In.) .018 .010 Price 14.34 14.34
967
Q313A1170
Provides power for a millivoltage, self-powered control system. Open circuit output: 600750 mV Use with Q314, Q324, Q327, Q377, Q379, Q382 pilot burners
"Super Slim Jim" universal K19AT thermocouples are designed for use with all Series "G" and "H" BASO valves, Basoids, and Basotrols with automatic pilot valves. The K19 is also interchangeable with thermocouples used with automatic pilot valves made by other control manufacturers whose power unit connector is similar to the BASO Series.
Part No. K19AT18 K19AT24 K19AT30 K19AT36 K19AT48 K19AT60 K19AT72 Length (In.) 18 24 30 36 48 60 72 Carton Qty. 10 10 10 10 5 5 5 Price/Ea. 15.92 17.84 17.42 18.62 24.16 26.26 28.52
Includes Spade Terminal 1/2" Nut Push In Clip PG9 Adapter Push In Clip & Nut Terminal Block
STANDARD
SNAP-FIT
The K15 Series thermocouples are designed for use in standing pilot ignition systems. They are used primarily with BASO brand automatic pilot controls and pilot burners. Millivoltage range: K15DS: 2028 mV K15FS: 2028 mV K15WS: 3035 mV
Part No. K15DS18 K15DS24 K15DS30 K15DS36 K15FS24 K15FS36 K15WS48 Length (In.) 18 24 30 36 24 36 48 Type STD STD STD STD Snap In Snap In Carton Qty. 10 10 10 10 10 10 5 Price/Ea. 15.58 16.42 17.24 18.10 16.70 17.56 26.50
The 1980 Series snap-fit thermocouples offer easy installation into the majority of pilot burners.
1980048 Part No. 1980018 1980024 1980036 1980048 Length (In.) 18 24 36 48 Price 8.40 8.78 10.12 13.30
ADAPTER
The Y99AN1 junction block adapter will fit any Johnson Controls thermocouple lead for conversion to a junction block application.
Part No. Y99AN1 Description Junction Block Adapter Price 68.94
HIGH PERFORMANCE
The Husky high performance K16 Series are heavy duty high performance thermocouples that provide high output. Millivoltage range: 2535 mV The K16WT are universal replacements, multi-mount
Part No. K16BT18 K16BT24 K16BT30 K16BT36 K16RA48C K16RA72C K16WT48 K16WT60 K16WT72 Length (In.) 18 24 30 36 48 72 48 60 72 Carton Qty. 10 10 10 10 5 5 5 5 5 Price/Ea. 32.18 34.00 34.64 35.02 51.30 81.62 66.84 74.62 76.16
THERMOPILE
Designed for use on self-powered gas and control systems. Can be used to replace all Robertshaw and similar competitive devices.
1950001 Part No. 19500011 1950532 19510011 1951536
1
968
GLOW COIL
Y80 Series glow coils are designed for use with G19, G21, and G29 ignition systems. They are used as replacements on existing pilot burners.
Y80AA48 Length (In.) 48 36
Used with Pilot Burners J(-)DHD, J(-)DLD, J(-)EKD, J(-)GHD, J(-)VHD J(-)HHD
IGNITION CONTROL
HOT SURFACE MODULE
Provides electronic control of 120V hot surface ignition systems used in furnaces, boilers and other heating appliances. Use with Norton 201 hot surface igniters or equivalent Supply voltage: 120 Vac and 24 Vac Controls igniter and gas flow
Lockout Timing Part No. S89C1095 S89C1087 (Sec.) 15 6 Comments Single Trial for Ignition Three Trials for Ignition, Prepurge Price 370.82 370.84
Panel Type
Provides operating control of a direct ignition system using a 120 Vac hot surface igniter. Provides easy field-replacement of a wide range of hot surface ignition modules manufactured by Honeywell, Robertshaw and White-Rodgers For 120 Vac (up to 5.0A) hot surface igniter (Norton 201/271 or equivalent) For local (single rod) or remote (dual rod) rectification type flame sensing 2 4
Part No. S8910U1000 Description Universal Hot Surface Ignition Control Price 254.94
Bulb Style
19
20
969
The 780 Series hot surface ignition modules are designed for use on gas fired heating systems. The system acts on a demand for heat by a switch or thermostat to supply power to the ignition control. On non-prepurge models, the ignitor will be energized immediately and remain on for either of two optional selected ignitor heat up times (approximately 17
Type Timer Part No. 780783 780785 780790 (psi) Prepurge, 34 Sec. Ignitor Warm-up, 34 Sec. Ignitor Warm-up, 17 Sec. Sensor Local Local Local Ignition Attempts Before Lockout 3 3 1
or 34 seconds). For models with the prepurge option, there is a time delay equal to the heat up time selected before the ignitor is energized. At the end of the ignitor heat up time the gas valve is opened supplying gas to the main burner. After several seconds, the ignitor is turned off and the sensor is energized. The 780 Series provides lockout and complete gas shutoff if ignition is not proven after the trial for ignition sequences has been completed.
Supply Voltage (Vac) 120 120 120 Replaces Rheem Rheem Rheem Price 209.14 201.42 201.12
The 780-910 Universal hot surface ignition module Uni-Kit is designed for use on gas fired systems. It is equipped with a self diagnostic LED for quick troubleshooting. The LED indicates if the system is in normal operation, has gone into lockout, has a weak flame signal, or has an internal error (a defective module). The 780-910 Uni-Kit will easily replace the widest variety of hot surface ignition modules found in the field today, including systems using: Local (sense through the hot surface ignitor) or remote flame sensors Single or three ignition attempts 4 or 7 second ignition trial time 17 or 34 second ignitor warm-up time 34 seconds or less prepurge Natural or LP gas controls The 780-910 comes equipped with field selectable options; flame sense (local or remote), ignition trial times and ignitor warm-up times. Electrical ratingSupply voltage: 120 Vac, 50/60 Hz Control input voltage: 24 Vac, 50/60 Hz Replaces most W/R 50E47, 50F47
Part No. 780910 Description Universal Hot Surface Module Price 194.62
50A55843
Universal replacements for existing W/R integrated silicon carbide (50A50/50A55) and silicon nitride (50A65) modules.
HOT SURFACE MODULE, INTEGRATED, FURNACE CONTROL KIT, OEM DIRECT REPLACEMENT
Replaces: White-Rodgers 50T55-289 and 50A55-289 and virtually All Goodman Single-Stage HSI controls with 120V ignitors. Features: 120 VAC Ignitor Output 120 VAC Humidifier Output 120 VAC Electronic Air Cleaner Output 120 VAC 2-Speed PSC Circulator Output Fuse Protection 5 Amp Furnace Status LED Heat Fan OFF Delay (Dipswitch Selectable) Y, W, R, G, C, TWIN Terminals Pre-purge time: 15 seconds
Part No. 50A55743 Description Single-Stage HSI Integrated Furnace Control Kit Price 155.68
Universal replacement for silicon carbide, non-integrated HSI modules. Replaces all 50E47 W/R and virtually all competitive silicon carbide, nonintegrated modules. Six insertable program keys cover most existing timing variations Tri-color LED indicator for diagnostics Direct and indirect flame sense
Part No. 50E47 843 Description Universal (NI) HSI Module Price 235.18
970
Replaces virtually all White-Rodgers and competitive single stage carbide and nitride HSI systems. Easy-Install Kit, includes: Ignition control module 9 Quick-Select/Quick-Connect wiring harnesses Universal nitride ignitor kit 21D642 Installation instructions and OEM cross-reference Features: 3 Fan speeds: cool, low heat and high heat (terminal connections) Color-coded thermostat connection System diagnostics, with fault recall (stored) Cover label displays diagnostic table Red LED light: used for diagnostic flash codes Low voltage, fuse protection, 3A replaceable automotive type Humidifier and electronic air cleaner connections (optional)
Part No. 50M56U843 Description Single Stage HSI Integrated Furnace Control Kit Price 261.46
Field service replacement for most Honeywell (S8610U), Robertshaw (780715), Johnson Controls (G779) and Utec Ignition Controls. 10 configuration options on modular control cards Provides ignition, proof of ignition and precise timing. Works with single rod or dual rod remote sensor. LED diagnostic indicator. 24Vac, 50/60 Hz, 0.2A
Part No. 50D50843 Description Universal Replacement Module, Proven Price 233.00
Controls gas valve, ignitor, blower, inducer, humidifier and air cleaner. Replaces Lennox models. Kit includes: (1) 50A66-843 Ignition Control Board (1) Wiring harness (9-pin to 12-pin) (1) Wiring harness (4-pin to 6-pin) (1) Mounting panel (4) Stand-off fasteners (1) Circuit breaker (1) 4" blue wire (2) Wiring diagrams Features: Includes diagnostic indicator flash codes 3 fan speeds Remote flame sense Humidifier and electronic air cleaner connections (optional)
Part No. 21D83M843 Description Single-Stage HSI Integrated Furnace Control Kit Price 373.68
Field service replacement for most Honeywell, Robertshaw, Johnson, and UTEC (HSC) intermittent pilot ignition modules. Provides electronic control of most intermittent pilot ignition systems used on gas-fired furnaces, boilers and other heating appliances. Provides ignition sequence, flame monitoring and safety shutoff for intermittent pilot central furnaces and heating appliances Provides 100 % pilot gas shutoff if pilot fails to light; after 6-minute delay, trial for ignition is repeated. Ignition trial/delay sequence is repeated until the appliance lights or call for heat is removed. For use with natural or LP gas Includes remote reset, automatic vent damper plug For use in single rod or dual rod/remote sense applications Supply voltage: 24V
Part No. S8610U3009 Lockout Time (Sec.) 15 or 90 Price 251.32
Price 204.28
Microprocessor based ignition control. which provides reliable software control of all timings and operates a diagnostic LED. It provides ignition sequence, flame monitoring, and safety shutoff for intermittent pilot boilers, furnaces and other heating appliances. BASO has designed-in features to retrofit other universal intermittent ignition controls with spark ignition and flame rectification such as: Johnson Controls, Honeywell, White Rodgers, Fenwal, Robertshaw. It replaces controls with the following specifications: Single rod (local sense) or dual rod (remote sense) flame sensing 100% shutoff/lockout with 5 minute continuous retry Trial times of 25 seconds or longer Prepurge period 1 second or less Main burner 400,000 BTU/hr maximum Pilot burners with flow rates of 1,500 Btu/hr or less With or without automatic vent damper Must be used with redundant gas valves and not subjected to temperatures below -40F or above 170F Direct replacement to Johnson Controls G779LHA.
971
Microprocessor based controls suited for direct replacement and new applications. They provide ignition sequence, flame monitoring, and safety shutoff for boilers, furnaces, and commercial cooking equipment. Intermittent pilot units are available with damper connection or without. Single rod (local sense) or dual rod (remote sense) flame sensing Trial for ignition 1 or 3 100% shutoff/lockout with none, 5 or 60 minutes continuous retry Trial times of infinite, 4, 5, 8, 10, 15, 20, 25, 30, 50, 60, 85, 90 and 120 sec. Pre-purge period of none, 4, 8, 10, 15, 30, 45, 60 sec. or 4 min. Main burner 400,000 Btu/hr max. Pilot burners with flow rates of 1,500 Btu/hr or less Temperature ranges of -40F to 170F
Part No. BG1600M00EK1AA BG1600M00ER1BD BG1600M00FP1AD BG1600M01ER1AD BG1600M01CR1BD BG1600M02CR1AD BG1600M10EK1AA BG1600M10FF1AA BG1600M10EM1AD BG1600M10ER1AD BG1600M11ER1AD Continuous Retry None 5 Minutes None 5 Minutes 5 Minutes 60 Minutes None None None None 5 Minutes Replaces* G600AY1, G670AW1 G770RJA G770MHC1C G775RGA G775RDJ2C, G775RJD15C G776RGD14C G600AX1 G600LX1 G770KHA2 G770RHA G775RHA Price 195.30 211.74 211.74 211.74 211.74 215.44 255.36 255.36 215.52 211.74 211.74
Provides electronic control of direct spark ignition systems used on gas fired furnaces, boilers, and other heating appliances. Includes alarm terminal
Part No. S87B1065 S87B1016 S87D1020 S87D1004 S87D1012 S87D1038 Lockout Timing (Sec.) 4 11 4 6 11 21 Comments Single Rod Single Rod Two Rod Two Rod Two Rod Two Rod Price 377.96 377.98 377.96 377.98 377.98 377.96
Provides electronic control of direct spark ignition systems, with external spark transformers, used on gas-fired furnaces, boilers, conversion burners and other heating appliances. Controls ignition sequence and gas control operation in direct spark ignition systems Lockout after one trial for ignition if main burner fails to ignite Supply voltage: 120 Vac and 24 Vac
Lockout Timing Part No. S89E1058 S89F1098 (Sec.) 4 4 Comments 30 Sec. Prepurge Price 403.58 403.56
When the thermostat calls for heat, the 780-845 control simultaneously initiates ignition sparking and opens the pilot valve portion of the gas valve. Pilot flame recognition stops ignition sparking and opens the main valve portion of the gas valve. Pilot burner flame is continuously monitored at a synchronous frequency for the duration of the heating cycle. Should the pilot flame fail during the heating cycle, the control will shut off the main valve until the pilot flame is established. The 780-845 lockout ignition control provides 90 seconds of spark (4 to 15 sparks per second), followed by a 6 minute time delay (purge) between ignition attempts. After three tries, if no pilot flame is sensed, the control goes into a one-hour lockout period. At the end of the lockout period, if the demand for heat is still present, the unit will repeat the three tries for ignition.
Part No. 780845 Description Intermittent Lockout Module Price 279.70
Microprocessor based controls suited for direct replacement and new applications. Direct spark modules provide ignition sequence, flame monitoring, and safety shutoff for boilers, furnaces, and a variety of other commercial cooking equipment. Direct spark modules are available with various specifications as follows: Single rod (local sense) or dual rod (remote sense) flame sensing 100% shutoff/lockout with none, 5 or 60 minutes continuous retry Trial for ignition 1 or 3 Trial times of infinite, 4, 5, 8, 10, 15, 20, 25, 30, 50, 60, 85, 90 and 120 sec. Pre-purge period of none, 4, 8, 10, 15, 30, 45, 60 sec. or 4 min. Main burner 400,000 Btu/hr max. Temperature ranges of -40F to 170F 24 Volt
Part No. BG1100MAAK1G BG1100MADL1G Ignition Trial Time (Sec.) 4 8 Pre-Purge Time (Sec.) None 30 Replaces G760BAD G765BCA-12R Price 195.30 195.30
Direct replacement for natural gas or propane ovens which have a Johnson Controls G891 Pulse Ignition Control
Part No. BGN8911C Description Lennox Pulse Replacement for G891 Price 258.78
972
The direct spark ignition unit is a microprocessor based gas ignition control designed primarily for direct ignition and burner supervision applications such as gas furnaces, boilers, water heaters and other similar devices. The system features direct main burner ignition, remote sensing, prepurge, retry for ignition and a fixed time for flame lockout time.
Ignition Attempts (Before Lockout) 1 1 3 3 Valve Trial Time (Sec.) 7 10 7 4
Local sensing type non prepurge control, thermostat reset model with isolated gas valve contacts, 1 ignition attempt before lockout, 10 second valve trial time, open board with 1/4" quick connects.
Part No. 35704600005 Fenwall Number 05-142301-005 Usage Lennox 31C0801 Price 455.14
Microprocessor based gas ignition control for natural or LP. Proof of flame is accomplished. Color LED indicator for diagnostics. Program keys. 1/4" and 3/16" quick connect terminals. Damper interface. 25 Vac nominal, 50/60 Hz, 0.2A
Part No. 50D50842 Description S87 Replacement Module, Direct Spark Price 233.00
Microprocessor based using software to determine the sequence of operation, timing, trial for ignition flame sensing and lockout Monitors the status of the room thermostat, limit and rollout switches, air pressure switch and flame sensor before energizing the vent motor, blower control, hot surface ignitor and gas valve Provides diagnostic LEDs to aid in troubleshooting Designed for 100% gas shutoff in case of ignition failure Compatible with 24Vac thermostats Twinning with similar boards Voltage range: 98 to 132 Vac; 60Hz
Part No. ICM280 ICM281 ICM282 ICM291 ICM292 Voltage 115/1/60 115/1/60 115/1/60 208/230/1/60 115/1/60
ICM280 replaces: Goodman/Janitrol: B18099-13, B18099-13S, B18099-10, B18099-08, B18099-06 UTEC: 1012-933D Texas Instruments: 41F-5 White-Rodgers: 50T35-730, 50T35-743 ICM281 replaces: Carrier: CESO11005700, CESO11005701, CESO11005702 ICM282 replaces: Carrier: HK42FZ(004,007,008,009,011,013,016)
MODULE UNI-KIT
MODULE ONLY
Robertshaw's universal ignition control Uni-Kits feature a flame sense circuit that will work equally well on a one rod (local sense) or 2 rod (remote sense) application. 780001 Not for hot surface Kits feature bracket, connector and hardware Input voltage: 24 Vac
Part No. 780001 780002 Type Non-Lockout Lockout, 60 Seconds Price 221.72 247.20
780735 Part No. 780715 780735 Type Non-Lockout Lockout Description Flame Rectification, Use w/7000BDER, 7100DER, 7200IPER Flame Rectification, Use w/7000BDER, 7100DER, 60 Second Timing Price 221.48 300.26
Replaces Goodman/Janitrol B18099-(06,08,10,13,13S), UTEC: 1012-933D Texas Instruments: 41F-5, White-Rodgers: 50T35-790, 50T35-743
Price 166.14
973
Convert "D" and "K" Series heat sensing/flame switch pilot ignition systems to "flame rectification" 780705 without replacing the existing gas valve. Included in each kit is a universal pilot mounting bracket with factory installed electrode and sensor, ignition control unit, wiring harness and complete in-depth instructions. The 780-704/705 modernizations kits DO NOT include a new gas valve. They are designed to utilize the existing gas valve. The existing gas valve is at least 12 years old or older. We suggest that a complete new 712 Series kit with a new gas valve be considered before using the 780-704 or 780-705 modernization kit.
Part No. 780704 780705 Type Lockout Non-Lockout Price 376.66 317.26
Designed to prevent the pilot flame from extinguishing. For LPG, natural gas etc. Sparks immediately upon detection of pilot flame going out Includes hardware kit, cable and module
Part No. PR2436W Power Input (Vac) 24 Price 85.12
RETROFIT
IGNITION, UNIVERSAL
PILOT RELIGHT
Ignition control generates spark pulses to ignite pilot gas. The relight control generates sparks until a pilot flame is sensed between the electrode and 505923 ground. The relight control detects a flame through "flame conduction". When flame current is sensed between the electrode and pilotburner ground, the relight control stops sparking. If the flame is extinguished during the heat call, the relite control will begin sparking the instant the flame goes out.
Input Voltage Part No. 5059134 505923 (Vac) 24 24 Connection Spike Connector Spark Plug, 1/4" Spade Price 163.66 157.34
Complete kits for converting conventional standing pilot systems to intermittent pilot systems. For use with 24 Vac gas-fired atmospheric furnaces, Y8610U3003 boiler and heating appliances. Y8610F kits are for use with natural gas only; continuous trial for ignition until the pilot lights or the system is shut down manually Y8610U kits are for use with natural or LP gas; provides 100% pilot gas shutoff if pilot fails to light; after 6-minute delay, trial for ignition is repeated. Ignition trial/delay sequence is repeated until the appliance lights or call for heat is removed. Each system includes: Intermittent pilot module, intermittent pilot dual valve combination gas control, LP gas conversion kit with Y8610U, igniter-sensor assembly, ignition cable (30"), wiring harness (30"), and reducer bushings
Part No. Y8610U4001 Y8610U6006 Type Gas Natural or LP Natural or LP Includes S8610U module, VR8204A valve, 1/2 x 1/2" S8610U module, VR8304M valve, 1/2 x 3/4" Price 468.66 545.00
PILOT RELIGHT
The Robertshaw 785 Series automatic pilot relight kits are designed for use on rooftop heating equipment, water heaters, boilers, space heaters, unit heaters, dryers, and other commercial, industrial, and residential appliances where the problem of pilot outage may occur. It should only be applied to those systems which already incorporate the necessary pilot-safety control system. Replaces most W/R 5059, 5059A
Electrical Rating Part No. 785001 (Vac) 120/24 High Voltage Output 15 kV Minimum Price 92.92
The Uni-Line 712 Series intermittent pilot ignition Uni-Kits feature solidstate logic and flame sensing (flame rectification) to provide automatic sequencing that will ensure proper 712008 operation of an intermittentpilot ignition device. Universal Uni-Kit models feature a gas valve with a natural gas pressure regulator installed and a separate LP gas regulator is included. The gas valve has a slow opening feature to provide soft ignition. Uni-Kits contain solid-state, prewired ignition control module, high capacity gas valve, universal electrode/sensor pilot assembly, installation instructions, and all necessary hardware.
IGNITION, LOCKOUT
Lockout model: 90 second spark, 6 minute delay, 3 tries, 1 hour lockout LP regulator included with kit
Gas Valve Part No. Size (In.) 700056 3/4 x 3/4 720070 1/2 x 3/4 700059 1x1 Module Part No. 780735 780735 780745 Natural Gas Capacity (BTUH) 350,000 200,000 720,000
974
GAS CONTROL
GLOWFLY
Natural Gas Capacity (BTUH) 350,000 200,000 720,000
Natural gas only. Designed to provide a robust field service replacement ignitor in gas fired appliances with Norton/St Gobain 120 VAC silicon carbide hot surface ignitors. The Q3200U uses a 120 volt silicon nitride ignitor design with long life and high resistance to damage or burn out in the appliance. The kit includes the specially designed silicon nitride igniter and six different bracket configurations to adapt the ignitor to the specific appliance application.
Part No. Q3200U1004 Q3200U2002 Description Single Kit Service Pack of 6 Kits Price 64.48 371.16
Gas Valve Part No. Size (In.) 700056 3/4 x 3/4 720070 1/2 x 3/4 700059 1x1
SENSOR
SPARK IGNITOR
Produces spark for direct ignition of main burner. Use with S87C, D, S89E, F; and Q354A
Ground Strap Part No. Q347A1004 Q347A1012 Orientation Standard 90 Angle Electrode Length (In.) 2 1/32 2 1/32 Price 58.14 58.72
IGNITOR
FLAME RECTIFICATION
Detects the presence of a main burner flame. Use with S825, S87C, D, K or S89E, F
Lower power consumption Engineered reaction bonded silicon carbide design - greater physical strength Superior gas lighting ability Includes: Ignitor, 3 mounting brackets, 1 self tapping screw, 2 porcelain wire nuts Replaces many OEM ignitors
Part No. SIG1100 Description Universal Price 48.34
Price 74.86
IGNITOR
CYCLE-PILOT ELECTRODE
76056
105.34
760401
Can be remotely mounted on multiple burners or adjacent to ignitor. Designed to detect the presence of flame. 760802 is exact replacement for OEM mode;
Lead Length (In.) 30 30 Price 61.06 110.04
Part No.
Description
Price
Replaces exact OEM ignitors Highest density silicon carbide greater physical strength Double helix design G1000 by using one of two included brackets replaces up to 100 original part numbers including Robertshaw 41-402, 403, 405, 407, 409, 410 IG101Replaces Nordyne 902661, 902694 Carborundum FC007, FC035, FC035KI IG102 Replaces Amana 10735002 Claire Bros C-238 (-1) Coleman 1474-511, 1474-521 Carborundum FC046, FC046KI Williamson 9050 York 025-32625-000, 025-32626-000, 373-05342-700, 373-09154-700, 473-12509-001
975
Replaces over 100 ignitors Universal hot surface silicon nitride ignitor; incorporates SI3N4 technology Non porous construction for longer ignitor life, uses half the power of silicon carbide ignitors
Part No. SSN2000 Description Universal Silicon Nitride Ignitor Price 43.16
The 41-600 Series Norton hot surface mini ignitors made of a unique, non porous, high strength proprietary material. Three second heat up and 41602 small size; easy handling, simple installation, trouble free operation. 41605 includes harness and brackets (conversion kit)
Part No. 41602 41603 41605 41 604 Factory Number Housing 601TB 601XBM 601XBM 601XBM None 2.5" 2.5" 4" Usage Amana 20165702 York 025-33421-000 York 473-20937-001 Armstrong 44744-2 Price 55.86 62.44 67.92 55.86
The 41-400 Series Norton hot surface ignitors are made of high-purity recrystallized silicon carbide (Crystar) which combines physical and thermal 41401 strength with stable electrical properties. The 41-400 Series is designed to reach ignition temperature(s) within 17 seconds. They have 18-gauge nickel chrome lead wires embedded and metalized in place for maximum holding strength and electrical conductivity. The lead wires are also enclosed with a special high temperature fiberglass insulation providing total electrical protection.
Ceramic Block Size Part No. 41401 41402 41403 41404 41405 41 406 41407 41408 41409 41410 41411 R41412 41413 41414
1
IGNITOR, CARBIDE
767A356 Part No. 767A356 767A357 767A361 767A365 Terminals 0.093" Male Pins 0.093" Male Pins 0.093" Male Pins 0.25" female spade Lead Length (In.) 6 5.25 5.25 5.688 Insertion Length (In.) 2.00 2.25 2.25 1.87 Price 59.52 59.52 58.88 59.52
Lead Length (In.) 4 1/2 19 5 1/2 4 1/2 5 1/2 10 1/2 4 1/2 4 1/2 4 1/2 4 1/2 4 1/2 4 1/2 36 1/4 12 Connector Style A None None D None None B C D B C D D D Price 41.60 40.40 38.62 40.40 42.80 45.08 40.40 40.40 40.40 40.40 40.40 39.82 83.14 69.82
Style (In.) A B C C D E C B C B B F F
IGNITOR, NITRIDE
1 5/8 1 1/4 2 2 1 1/4 1 7/8 2 1 1/4 2 1 1/4 1 1/4 1 1/4 1 3/82 1 1/4
AMP terminal receptacles with female sockets. White teflon coated leads. Steatite insulator with or without (768A845) steel zinc plated mounting tabs. 54mm ignitor element length.
Part No. 768A842 768A843 768A844 768A845 OEM Amana, 11111701 Thermo, 768A-143 Lennox, 41K5601 Trane, B340970P01 Terminals (In.) 0.093 0.084 0.084 0.084 Price 55.70 55.70 55.70 55.70
Designed to replace silicon carbide and older silicon nitride ignitors Upgrades silicon carbide integrated or non integrated systems to long lasting and durable nitride Kit includes universal ignitor mounting bracket, ignitor with 15 1/2" leads, mounting adapter bracket, 2 ceramic wire nuts, cross reference, instruction booklet and upgrade label for the furnace Super tough nitride ignitor construction; no more broken ignitors Easy ignitor replacement. 3 year warranty
Part No. 21D642 Description Nitride Upgrade Kit Price 59.14
976
These rubber seat poppet type regulators are designed primarily for main burner and pilot load applications where precise control of tiny flows is an RV481/2 essential operating requirement. Housings are of high strength aluminum die castings. All models have been tested for multi-poise mounting and may be installed in any plane
Connection Size FPT (In.) 3/8 1/2 3/4
or angle without restriction. Other than normal upright position will result in slight difference of outlet pressure. They may be used with natural, manufactured, mixed, LP, or LP gas-air mixture. Maximum inlet pressure: 1/2 psi RV48 Leak limiting devices 12A04 or 12A06 must be used if not vent piped to code
Standard Spring (In. W.C.) 2.8 to 5.2 3.0 to 6.0 3.0 to 6.0
Range of Regulation (BTUH) Main Main Burner Burner & Pilot 150 to 75,000 150 to 50,000 150 to 230,000 150 to 230,000 150 to 250,000 150 to 250,000
STRAIGHT-THRU-FLOW
Main burner only, non-lockup type. They should not be used as a line gas pressure regulator ahead of low pressure controls. Use only where RV531 downstream controls can operate at line pressure. Suitable for multi-poise mounting. The flow pattern
Part No. RV521/2 RV523/4 RV531 RV533/4 RV611 Connection Size FPT (In.) 1/2 3/4 1 3/4 1 Regulation Range (CFH) 151 to 956 151 to 956 217 to 1,369 217 to 1,369 379 to 2,464
provides accurate sensitive regulation at extremely low pressure differentials. Straight-thru-flow appliance regulators are intended for use with all fuel gases, and may also be used with air or other noncorrosive gases within their pressure limits. Maximum inlet pressure: 1/2 psi, except RV611 which is 1 psi Standard spring: 3" to 6" W.C.
Dimensions (In.) H 4 7/8 4 7/8 5 13/16 5 13/16 6 7/16 L 3 3/16 3 3/16 3 3/4 3 3/4 4 3/8 Price 78.50 78.50 107.33 107.33 152.33
Pounds to inch regulator, meeting utility specifications, for use on residential, commercial, and industrial applications where adequate inlet pressures are 32531/2 available. Suitable for multi-poise mounting, except with vent limiting device
Connection Size FPT (In.) 1/2 1/2 3/4 1 1/2 Regulation Range (CFH) 100 to 320 225 to 680 225 to 680 470 to 2,000
Can be used as a single stage regulator or a first-stage on two-stage system May be used for both 2 psi and 5 psi flexible tubing house piping systems Precise regulation from pilot flows to full regulator capacity Regulation range (CFH) based on outlet pressure setpoint of 10" W.C.
CONTROLS & ELECTRICAL ACCESSORIES
Dimensions (In.) H 3 1/2 5 1/4 5 1/4 7 1/4 L 4 1/4 5 7/8 5 7/8 8 Price 46.75 92.17 90.33 231.67
977
HEATING
GAS REGULATOR
BALANCED VALVE DESIGN SPRINGS
Intended for use with both main burner and pilot load applications. Ideally suited for use with infrared heaters and pilot lines on large industrial heaters R500S and boilers. These regulators are not suitable for dead-end lock-up service. They are capable of controlling pressure at very low flows such as standing pilots, but should not be used as a line gas pressure regulator for appliances equipped with electronic ignition unless automatic control valve can open against line pressure. Suitable for multi-poise mounting and all fuel gases Standard spring: 3" to 6" W.C.
Connection Part No. R400S R500S R600S FTP (In.) 1/2 3/4 1 Regulation Range (CFH) 86 to 303 196 to 876 330 to 1,480 Dimension H x L (In.) 3 1/4 4 2/3 5 2/3 2 3 1/8 3 7/8 Price 76.42 109.25 197.00
R521036 Outlet Pressure Part No. R521036 R6010512 R81101022 R811036 R8110412 R811048 R9110412 Range (in W.C.) 3 to 6 5 to 12 10 to 22 3 to 6 4 to 12 4 to 8 4 to 12 Color Code Plated Blue Red Plated Violet Orange Violet Usage RV52, RV500S RV61 RV81, 210D RV81, 210D RV81, 210D RV81, 210D RV91, 210E Price 2.50 3.33 22.58 7.58 7.58 7.58 11.17
SPRING LOADED
For gas fired boilers, steam generators, industrial furnaces, ovens and similar high demand equipment. Balanced valve design eliminates the inlet pressure effect acting on the valve. Intended for use with all gas fuels. The regulator should be mounted in an upright position in a horizontal pipe run. The 210 Series is a lock-up type regulator and complies with codes using this specification. Designed to operate as a zero governor in the normal upright position Standard spring: 3" to 6" W.C.
Connection Part No. 210E11/2 FPT (In.) 1 1/2 Regulation Range (CFH) 4,450 to 10,500 Dimension H x L (In.) 11 1/4 7 5/8 Price 1161.25
For control of high limit and fan motor in all types of forced air heating systems. The L4064 is the fastest responding fan and limit available.
L4064B2210
L4064W features a 2090 second preheat before fan start L4064B, W models have manual fan switch that overrides fan control to keep fan running continuously High limit: 100250F Differential: 25F, fixed Fan on: 65215F Differential: 22F minimum Fan off: 50200F Contact rating Fan: 7 F.L. Amp @ 240 Vac Limit: 4 F.L. Amp @ 240 Vac
Element Insertion Part No. L4064B2210 L4064B2228 L4064B2236 L4064W1098 Length (In.) 11 1/2 5 8 8 Mounting Bracket Surface Surface Surface Surface or Rigid Price 174.34 174.34 174.34 267.86
VENT LIMITER
Automatic vent limiting device ball check permits free inhalation for fast regulator diaphragm response on opening cycle, but limits gas 12A39 escapement should a diaphragm rupture. May be used in multi-poise mounting, but when using the vent limiting device, regulator must be mounted in a horizontal upright position for best performance. RV81, RV91, RV111, 325-7, 210 Series must be vent piped per code
Part No. 12A04 12A06 12A09 12A39 Description IAS Certification 14" W.C., 1/8" MPT Orifice Only, Less Ball Check IAS Certification 2 psi LP 5 psi Natural with Model 325-3, 1/8" MPT IAS Certification 2 psi LP 5 psi Natural with Model 325-5A, 3/8" MPT Usage RV48, RV52 RV53, RV61 RV48, RV52 RV53, RV61 325-3, R & RS 325-5A Price 7.33 4.83 7.58 18.92
FAN OR LIMIT
Single fan or limit control starts and stops fan operation and provides positive reliable high limit protection on warm air furnaces. Switch: SPDT Contact rating: 3.7 F.L. Amp @ 240 Vac
Range Part No. 4164 (F) 100 to 350 Differential (F) 20, Fixed Element Length (In.) 9 Price 266.80
978
HEATING
FAN AND LIMIT LIMIT, L4029 SERIES
Turns the blower on and off as a function of temperature. Adjustable fan differential Limit differential: 30F, fixed
FAL3C05TD120 Element Part No. FAL3C05TD120 FAL7C05TD120 3 7 Fan Off 90 to 120 90 to 120 Fan 25 to 50 25 to 50 Limit Price 150 to 250 164.16 150 to 250 166.66
Opens line or low voltage circuit and shuts off fan if air temperature reaches setpoint. Manual reset L4029E1219 May be used as a fire stat in ductwork Positive lockout of burner in case of fan failure Contact rating: 5 F.L. Amp @ 240 Vac Duct mounting: 3" insertion
Part No. Fixed Cutout Setting (F) 135 200 240 165 125 Price 206.14 206.14 206.14 206.14 206.14 L4029E1011 L4029E1029 L4029E1045 L4029E1219 L4029E1227
Single element type for applications with narrow space limitations Regulates fan or blower operation and acts as high limit safety control 5D5178 Designed to be interchangeable with other flush mounted, single element fan and limits Range: fan -50 to 265F, differential 1570F Limit: 100 to 300F, differential 25F, fixed Switch: fan SPST, close rise, 7.0 F.L. Amp @ 240 Vac Limit: SPST, open rise, 6.0 F.L. Amp @ 240 Vac
Part No. 5D5135 5D5190 5D5178 Element Length (In.) 5 8 11 Price 167.84 167.84 167.84
LIMIT
Safety device which cycles the blower and gas valve in case the fan control device fails. SPDT switching action
Off Temperature (F) 120 to 250 120 to 250 Price 75.44 77.62
Length (In.) 3 7
FAN
Turns the blower on and off as a function of temperature. Fan off temperature: 90 to 120F Fan differential: 25 to 50F
F473TD12025C Extension Element Length (In.) 3 7 3 7 Price 152.68 155.22 152.56 154.58
Differential (F) 25, Fixed Switch SPST, Open Rise Price 68.74
Turns the blower on and off as a function of time and temperature. Includes limit portion for safe operation of furnace. Adjustable fan off temperature setting Adjustable limit temperature setting Includes a "Heat Assist" circuit to provide a timed blower on function Element length: 7"
Fan off Part No. FALTS57C05T FALTS57C65T Temp (F) Limit Temp. (F) Limit Differential (F) Comments 30, Fixed 30, Fixed 30, Fixed w/Element Shield SPDT
FAN, TIME/TEMPERATURE
Turns the blower on and off as a function of time and temperature. Adjustable fan off temperature setting FA47TS7110 Includes "Heat Assist" circuit to provide a timed blower on function Time delay at 24 Vac: 2560 seconds Fan differential: 50F, fixed
Element Part No. Length (In.) 3 7 Fan Off Temperature (F) 90 to 120 90 to 120 Price 179.90 188.12
FA47TS3110 FA47TS7110
979
HEATING
WARM AIR CONTROL
TIME DELAY FIRESTAT, DUCT
Used in controlling high current blowers, relays and contactors. 24 Vac input Available in SPST and SPDT S1061B6545C configurations Provides delay on and delay off timing Contact ratingNormally open terminals: 8 F.L. Amp @ 240 Vac Normally closed terminals: 2.9 F.L. Amp @ 240 Vac
Timing (Sec.) Part No. S1061A4575C S1061A5040C S1061B6545C Switch SPST SPST SPDT Delay On 30 to 50 45 to 55 60 to 70 Delay Off 60 to 90 30 to 50 45 to 75 Price 126.92 126.90 126.92
Manual reset fan safety cutoff switch. Provides shutdown of fan operating whenever duct temperature rises to a point that indicates the presence of a fire. Contact rating: 4 F.L. Amps @ 240 Vac Maximum ambient temperature: 190F at switch, 350F at element
Operating Part No. L4064K1014 Switch SPST Open Rise, Manual Reset Range (F) 50 to 165
FIRESTAT, DUCT
The A25 warm air controls lock out on a temperature increase to the control set point. Manual reset is required before the electrical contacts can be reclosed. The A25 is normally located in a return air duct and wired to shut down air conditioning or ventilating fans when the temperature of the air becomes excessive, as from a fire.
Range Part No. A25AN1 Switch SPDT, Open High (F) 25 to 215 Differential (F) Manual Reset Limit (F) 125
Construction with 125F stop setting meets requirements of NFPA 90A, Standard for the installation of air conditioning and ventilating systems for return air ducts of gypsum board construction.
Wide range temperature control with special air coil sensing element and adjustable mounting flange. These duct thermostats are used on roof top units, make-up heaters, duct heaters, and air handling systems of all types.
Range Part No. A19EAF1 Switch SPDT SPDT (F) 60 to 130 30 to 110
A19EAF2
REMOTE BULB
HIGH RANGE
The A19 Series are single stage temperature controls that incorporate liquid filled sensing elements. Suitable for temperature control in heating, ventilating, and refrigeration.
Oven thermostat
980
HEATING
CROP DRYING
Range Part No. A19AAE3 Switch SPST, Open High (F) 80 to 180
ACCESSORIES
S437A1009
WINTER WATCHMAN
Responds to the air velocity in heating or warm air ducts. Contact rating: 5.1 F.L. Amp @ 240 Vac
Operating Velocity Part No. S637A1004 S437A1009 Switch SPDT SPST (fpm) 1,9002,250 1,9002,250 Sail Dimension (In.) 1x3 1x3 Price 184.18 164.62 Part No.
Used as a freeze warning device. Completes circuit to household lamp on temperature fall, indicating inoperative heating equipment. Lamp plugs into receptable at bottom of "Winter Watchman" device Useful when house is unoccupied to notify a neighbor of a temperature drop so heating source fault can be rectified before freeze-up occurs
Temperature Range (F) 3060 Price 61.06 S483B1002
Used in forced air systems to activate electronic air cleaners, humidifiers or other auxiliary equipment in response to airflow from system fan. Red flag drops into window on fan compartment suction increase
Operating Part No. S688A1007 Switch SPDT Velocity (fpm) 75 to 250 Sail Dimension (In.) 5 x 10 Price 109.14 Part No. Y99AU3
SIGNAL TRANSDUCER
The Y99AU3 signal transducer, used in conjunction with a hand-held digital multimeter, allows for easy measurement of direct current (DC) as precise as 0.01 microampere.
Description Signal Transducer Price 148.46
Outdoor heat pump thermostats. Provides auxiliary heater "lockout" during mild weather Switch: SPST open rise Contact rating : 6.0 F.L. Amp @ 240 Vac
Differential
E152601
981
HEATING
HEAT PUMP REVERSING VALVE
REVERSING VALVE
These solenoid operated reversing valves are slide type, 4 way with a 4 way pilot valve and operate under the full pressure of the heat pump system. The valves are used on unitary, split system, and window-type heat pump applications. There are six different styles designed to meet your particular system need. Coils not included uses LDK style
V10-414120-170
OPPOSED PARALLEL
V3-412080-870
Part No. V2 408060 170 V6 412080 170 V6 414080 170 V6 414120 170 V10 414080 170 V10 414120 170 V10 418140 170 V10 414140 470
Capacity (Tons) R407C R410A 0.8 to 1.8 .9 to 2.2 1.1 to 5.4 1.3 to 6.7 1.1 to 5.4 1.3 to 6.7 1.1 to 5.4 3.2 to 9.4 3.2 to 9.4 3.2 to 10.7 3.2 to 9.4 1.3 to 6.8 3.8 to 10.1 3.8 to 10.1 3.8 to 11.7 3.8 to 10.1
Tube Size IDS (In.) Suction High 1/2 3/8 3/4 1/2 7/8 1/2 7/8 7/8 7/8 1 1/8 7/8 3/4 1/2 3/4 7/8 7/8
Capacity (Tons) Replaces Price V2128 214.60 V62101 324.20 V62103 331.90 V102500 V102750 V102762 V102765 386.40 457.98 455.14 456.10 458.10 Part No. V3 410080 770 V3 412080 870 R407C 1.1 to 2.7 1.1 to 2.8 R410A 1.3 to 3.1 1.3 to 3.5
Tube Size IDS (In.) Suction 5/8 3/4 High 1/2 1/2 Replaces V31003 V31004 Price 233.28 247.40
LOOPBACK FLARE
LOOPBACK PARALLEL
Capacity (Tons) Part No. V2 410060 470 V2-408060-270 Capacity (Tons) R407C R410A .4 to 1.3 .5 to 1.7 0.8 to 1.8 .9 to 2.2 Tube Size IDS (In.) Suction High Replaces Price 3/8 3/8 V1158 184.68 1/2 3/8 V2100 209.04 R407C 1.1 to 2.0 R410A 1.3 to 2.5 Tube Size IDS (In.) Suction 5/8 High 3/8 Replaces V2150 Price 215.40
Part No.
R407C
R410A
Type LDK solenoid coils for use with the current Vx-xxxxxx-xxx series "Generation 4", Ranco heat pump reversing valves are epoxy encapsulated, continuous duty, moisture-resistant magnetic coils designed to operate the pilot valve controlling the reversing valves. Included with the solenoid coil is a wiring harness.
Part No. Voltage (Vac) 24 120 240 277 Color Red Black Green Blue Price 66.50 71.20 71.38 88.64
OPPOSED FLARE
LDK 110000 070 LDK 310000 070 LDK 410000 070 LDK 510000 070
Capacity (Tons) Part No. R407C R410A V2 4100F0 370 1.1 to 2.0 1.3 to 2.5
Tube Size IDS (In.) Suction 5/8 High 3/8 OD Replaces V2179 Price 219.58
982
HEATING
HYDRONIC CONTROL, TEMPERATURE
L4006A1009
AQUASTAT
Immersion-type controllers for limiting or regulating temperatures of liquids in boilers or tanks. Contact rating: 5.1 F.L. Amp @ 240 Vac
Part No. L4006A1009 L4006A1017 L4006A1132 L4006A1678 L4006A19591 L4006E1067 L4006H1004 L6006A1145 L6006C1018
1
Application High/Low Limit High/Low Limit High/Low Limit High/Low Limit High/Low Limit High Limit High Limit Circulator, High/Low Limit Circulator, High/Low Limit
Switch SPST, Open Rise SPST, Open Rise SPST, Open Rise SPST, Open Rise SPST, Open Rise SPST, Open Rise SPST, Open Rise SPDT SPDT
Temperature Range (F) 100 to 240 100 to 240 100 to 240 100 to 240 40 to 180 110 to 270 100 to 240 100 to 240 65 to 200
Includes 1.5" Insulation 1.5" Insulation 3" Insulation 3" Insulation, Well Adapter 1.5" Insulation, Well Adapter 3" Insulation, Well Adapter Strap On, Well Adapter 3" Insulation, Well Adapter Strap On, Well Adapter
Price 258.88 249.96 254.98 185.20 188.14 268.72 279.96 195.50 181.28
For limiting or regulating temperature of liquids in boilers or tanks. Can also sense outside or duct air temperature. Contact rating: 5.1 F.L. Amps @ 240 Vac
Temperature Range Part No. L4008A1015 L4008A1130 L4008B1013 L4008E1156 L6008A1192 Application High/Low Limit High/Low Limit Circulator High Limit Circulator, Low Limit Switch SPST, Open Rise SPST, Open Rise SPST, Open Rise SPST, Open Rise SPDT (F) 100 to 240 130 to 270 100 to 240 130 to 270 100 to 240
Differential (F) 5 to 30 5 to 30 5 to 30 Manual Reset 5 to 30 Includes 5 1/2' Capillary 10' Capillary 5 1/2' Capillary 5 1/2' Capillary 5 1/2' Capillary Price 228.78 378.10 226.30 256.40 314.36
AQUASTAT, MULTIPLE
High limit, low limit and/or circulator controllers used to regulate boiler water temperature in gas- or oil-fired hydronic heating systems. Contact rating: 5.1 amps @ 240 Vac
Part No. L4081A1023 Application High/Low Limit
Switch 2-SPST
Price 395.76
L8100B1037
Immersion-type controller for regulating and limiting the tank temperature in water heaters. Regulates temperature and provides energy cutoff (ECO) action on a temperature rise past the set point. Includes a second sensing element that senses average water temperature to minimize stacking.
Switch SPST, Opens on Rise SPST, Opens on Rise
Operating range: 100180F Differential controller: 5F, fixed ECO: 20F, fixed Contact rating: 2 amps @ 24V
Operating range: High limit: 130240F Differential: 10F, fixed Low limit/Circulator: 110220F Differential: 1025F
983
HEATING
HYDRONIC CONTROL, TEMPERATURE
AQUASTAT, TRIPLE
L8124G1020
Immersion-type controllers that combine high limit protection with low limit and circulator control in forced hydronic heating systems, including domestic hot water service. Provides multizone control by using a separate circulator and R845 Relay for each zone Units with well adapter less well
Application Multizone Capable Multizone Capable Single Zone Control Multizone Capable Multizone Capable Multizone Capable Burner Voltage 120 120 Millivoltage 24 120 120 Mounting Vertical Vertical Vertical/Horizontal Vertical/Horizontal Vertical/Horizontal Vertical/Horizontal
Operating range: High limit: 130240F Differential: 10F, fixed Low limit/Circulator: 110220F Differential: 1025F Contact ratingCirculator: 3.7 F.L. Amp @ 240 Vac
Includes 3" Insertion Well 3" Insertion Well Universal Element, Well Adapter Universal Element, Well Adapter Universal Element, Well Adapter Universal Element, Well Adapter
120 Vac Oil Electronic Aquastat Controller with Enviracom communication and troubleshooting Leds. Provides electronic temperature sensing in a UL limit-rated controller with a single sensing probe. The L7224U controls the circulator, oil burner and boiler temperature. It replaces the L8124A,
Part No. L7224R1000 L7224U1002 Differential (F) High Limit: 5 to 20 adj. High Limit: 5 to 20 adj. Height Width (In.) (In.) 7 1/8 4 1/4 7 1/8 4 1/4 Depth (In.) 2 5/8 2 5/8
L8124C, L7124U, L7148A, L7248A,C, L7224A,C, and L8148A Controllers. The Aquastat Controller is intended for use in residentialtype applications. It provides status and diagnostic information through an LED display combined with LED lights to enhance the diagnostic process. Operating range: High limit: 130240F Low limit: 110220F
Mounting Well mount, horizontal or vertical position, or flush mounted remote from the well Well mount, horizontal or vertical position, or flush mounted remote from the well Price 596.52 307.52
AQUARESET KITS
AQUASTAT RELAY
Outdoor Reset Kit Simple installation with three wire connection to the Aquastat Compatible with any L7224/L7248 Outdoor Reset Ready Aquastat, S9361A Integrated Boiler Control, and R7910 SOLA Controls Domestic Hot Water Kit Compatible with Honeywell AquaReset wired and wireless kits Ensures domestic hot water needs are met when combining AquaReset with an indirect DHW tank. Easy three-wire installation to AquaReset module Alarm Module Works with any alarm generating EnviraCOM enabled control Local LED alarm present and communication active indication Simple low-voltage, 5-wire installation
Part No. W8735S1000 W8735S1008 W8735S3000 Description AquaReset Outdoor Reset Module AquaReset Domestic Hot Water Kit EnviraCOM Alarm Module Price 397.68 152.42 39.78
Immersion-type controllers that combine high limit protection with switching relay control of burner and circulator motors. Horizontal and vertical mounting Includes well adapter, heat conductive compound Contact rating: 5.1 amps @ 240 Vac
Burner Circuit Mounting Line Voltage Horizontal L8148A1017 Low Voltage Vertical L8148E1265 Low Voltage Vertical L8148E1299 L8148J1009 Low, mV Voltage Horizontal and vertical Part No. High Limit (F) 120 to 240 180 to 240 120 to 240 120 to 240 Price 314.56 396.10 379.24 357.70
984
HEATING
HOT WATER, WELL IMMERSION
Hot water control for hot water boilers Furnished with well assembly for 1/2" NPT
A19ABC11 Range Part No. A19ABC11 A19ABC12 Switch SPDT SPDT (F) 100 to 240 100 to 240 Differential (F) 6 to 24 6 to 24 Capillary Length (Ft.) Flush 8 Max. Bulb Temp. (F) 250 290 F.L. Amps (@ 240 Vac) 6.0 6.0 Price 158.06 176.46
Strap-on, surface type hot water control Automatic changeover control for fan coil systems
11272
Attach directly to surface of pipe Strap-on eliminates need for tapping of boiler or draining system Sensing element has twice the contact area of competitve models
Range Part No. 11B021 11272 (F) 100 to 240 100 to 240
Differential (F) 10, Fixed 10, Fixed Switch SPST, Open Rise SPDT
Control has thermal element immersed directly in the water for use as a high limit and/or operating control. Use as a high limit, low limit, circulator control or combination low limit and circulator control. Specially designed hydraulic action element for fast response to temperature change. Bulb extension: 11 3/16" beyond threads Thread size: 1/2 in. Contact rating: 6.0 F.L. Amp @ 240 Vac
Range Part No. 114533 (F) 100 to 240 Differential (F) 5 to 45 Switch SPST, Open Rise Price 324.94
With 7/16 to 2 7/16" bulb. All include 1/2" standard shank well.
Range Part No. 11B05101 11B18101 11B18153 1131102 (F) 100 to 240 100 to 240 35 to 110 100 to 240 Differential (F) 5 to 45 5 to 45 2, Fixed 7 to 45 Switch SPST, Close Rise SPST, Open Rise SPST, Open Rise SPDT F.L. Amps (@ 240 Vac) 7.0 6.0 6.0 3.7 Price 286.50 250.88 250.88 227.30
Price 778.28
11B18101
Types for use as high limit, reverse action or SPDT switching action; may be mounted either horizontal or vertical.
INDOOR/OUTDOOR RESET
Cuts fuel costs and provides utmost comfort performance from conventional hot water heating systems; especially ideal for zoned systems. Fully adjustable reset ratio covers all climate conditions and eliminates stocking controls with different reset ratios Well-insertion bulb monitors boiler water temperature; outdoor bulb monitors outdoor temperature. Control modulates water temperature based on reset ratio selected. Capillary length: 15 feet to inside bulb, 30 feet to outside bulb Reset ratios adjustable from 1.5/1 to 1/1.5 Contact rating: 7.0 F.L. Amp @ 240 Vac
985
HEATING
VALVE, HYDRONIC CONTROL
ZONE, LINE VOLTAGE
V4043A1002
On/off and diverting line voltage valves consist of an actuator motor and valve assembly for controlling the flow of hot or chilled water and some models for steam. Manual opener (on all models, except straightthrough, normally open valves) for valve operation on power failure; valve returns to automatic position when power is restored
De-energized Capacity (Cv) 3.5 3.5 8.0 10.0 3.5 3.5 3.5 4.0 4.0 7.0 4.0 Pattern Straight-Thru Straight-Thru Straight-Thru Straight-Thru Straight-Thru Straight-Thru Straight-Thru 2-Position Diverting 2-Position Diverting 2-Position Diverting 2-Position Diverting
2
All models may be installed without disassembling the valve Complete powerhead may be removed or replaced without breaking line connections or draining the system
Connection (In.) Size 1/2 1/2 3/4 1 1/2 1/2 1/2 1/2 1/2 3/4 1/2 Type Flare Sweat Sweat NPT Sweat Sweat Sweat Sweat Sweat Sweat Sweat Voltage 120 120 120 120 120 240 120 120 240 120 120 Price 174.28 174.28 192.86 257.46 186.40 188.34 196.72 188.76 188.76 207.18 231.40
Part No. V4043A1002 V4043A1010 V4043A1259 V4043A1697 V4043B1018 V4043B1059 V4043E10031 V4044A1019 V4044A1050 V4044A1191 V4044B10172
1
Position Normally Closed Normally Closed Normally Closed Normally Closed Normally Open Normally Open Normally Closed Port A Normally Closed Port A Normally Closed Port A Normally Closed Port A Normally Closed
Steam only
V8044A1044 De-energized Part No. V8043A1011 V8043A1029 V8043B1076 V8043E1004 V8043E1012 V8043E1020 V8043E1061 V8043E1145 Pattern Straight-Thru Straight-Thru Straight-Thru Straight-Thru Straight-Thru Straight-Thru Straight-Thru Straight-Thru Straight-Thru Straight-Thru Straight-Thru Straight-Thru 2-Position Diverting 2-Position Diverting 2-Position Diverting 2-Position Diverting 2-Position Diverting 2-Position Diverting Position Normally Closed Normally Closed Normally Open Normally Closed Normally Closed Normally Closed Normally Closed Normally Closed Normally Closed Normally Closed Normally Closed Normally Open Port A Normally Closed Port A Normally Closed Port A Normally Closed Port A Normally Closed Port A Normally Closed Port A Normally Closed Capacity (Cv) 3.5 3.5 3.5 3.5 3.5 3.5 8.0 3.5 3.5 3.5 3.5 4.0 4.0 7.0 4.0 4.0 7.0 Connection (In.) 1/2 Sweat 3/4 Sweat 3/4 NPT 1/2 Sweat 3/4 Sweat 1 Sweat 3/4 Sweat 3/4 NPT 1/2 Sweat 3/4 Sweat 1 Sweat 1/2 NPT 1/2 Flare 1/2 Sweat 3/4 Sweat 1/2 NPT 1/2 Sweat 3/4 Sweat End Switch Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Price 160.88 161.50 180.44 158.96 170.10 193.80 170.10 182.32 191.62 184.34 207.90 192.90 189.18 182.20 201.00 194.26 197.70 208.78
V8043F1028 V8043F1036 V8043F1051 V8043J10291 V8044A1002 V8044A1010 V8044A1044 V8044A1135 V8044E1003 V8044E1011
1
Steam only
986
HEATING
ZONE, LOW VOLTAGE
Control voltage: 24 Vac. Install without disassembly, compact construction for easy installation Manual opener
LINEAR WATER
Controls hot and/or chilled water for VAV terminal units, fan coil units, small reheaters and recoolers in electric/electronic temperature control systems. Used with the M6410 (non spring return)/M6435 (spring return) small individual room controller 3-position floating electronic linear valve actuator or M7410 (non spring return)/M7435 (spring return) selectable 0 to 10 Vdc or 2 to 10 Vdc electronic actuator, or MP958 (2000 series valves only) pneumatic valve actuator. Larger valves (1 to 1-1/2" ) are pressure balanced, which results in higher close-off pressures. Long stroke allows wider range of control. Soft valve seat provides low leakage rate. Inserts for 1/2 and 3/4" valves are changeable without draining valve when used with an insert replacement tool. Brass body, seat, cartridge, stainless steel stem. Threaded plastic cover/manual handle allows manual operation. 1/2, 3/4" valves equal percentage flow, 1 to 1 1/2" valves linear flow
2 WAY , CARTRIDGE GLOBE, WATER
V5853A2030 Connection Size (Nom.) 1/2 1/2 1/2 1/2 1/2 3/4 3/4 3/4 3/4 (In.) Type Sweat Sweat Sweat Sweat Sweat Sweat Sweat Sweat Sweat Flow (Cv) 0.29 0.47 0.74 1.2 1.9 2.9 4.9 2.9 4.9
Part No. V5853A2006 V5853A2014 V5853A2022 V5853A2030 V5853A2048 V5853A2055 V5853A2063 V5853A1008 V5853A1016
Price 80.06 80.06 80.06 80.06 80.06 108.18 108.18 95.76 95.76
V5852A2015 Connection (In.) Part No. V5852A2007 V5852A2015 V5852A2023 V5852A2031 V5852A2049 V5852A2056 V5852A2064 V5852A2072 Size (Nom.) 1/2 1/2 1/2 1/2 1/2 1/2 3/4 3/4 Type Sweat Sweat Sweat Sweat Sweat Sweat Sweat Sweat Flow (Cv) 0.19 0.29 0.47 0.74 1.2 1.9 2.9 4.9 Price 52.56 52.56 52.56 52.56 52.56 52.56 75.68 75.68
Part No. V5863A2004 V5863A2012 V5863A2020 V5863A2038 V5863A2046 V5863A2053 V5863A2061 V5863A1006 V5863A1014 V5863A3002 V5863A3010 V5863A3028 V5863A3036 V5863A3044
Connection (In.) Size (Nom.) Type 1/2 FPT 1/2 FPT 1/2 FPT 1/2 FPT 1/2 FPT 1/2 FPT 3/4 FPT
Connection (In.) Size (Nom.) Type 1/2 FPT 1/2 FPT 1/2 FPT 1/2 FPT 1/2 FPT 3/4 FPT 3/4 FPT 3/4 FPT 3/4 FPT 1 FPT 1 FPT 1 FPT 1 1/4 FPT 1 1/2 FPT
Flow (Cv) 0.29 0.47 0.74 1.2 1.9 2.9 4.9 2.9 4.9 5.5 7.8 11 18 25
Price 82.02 82.02 82.02 82.02 82.02 117.56 110.82 110.82 102.74 197.70 183.10 194.94 256.80 313.84
987
HEATING
VALVE, HYDRONIC CONTROL
M6410A1029
Small individual room control (IRC) electric actuators provide floating or modulating control of V5852, V5862 two-way or V5853, V5863 three-way valves. Suitable for Excel/IRC system or other controllers providing specified signals
Part No. M6410A1029 M6410A3017 M7410F1000 M7410F3006 Control Mode SPDT Floating SPDT Floating 0-10 Vdc, 2-10 Vdc 0-10 Vdc, 2-10 Vdc Stem Force (Lbf) 40.50 67.50 40.50 67.50
Magnetic coupling for torque limitation independent of voltage supply and self-adjustment of the closeoff port Power supply: 24 Vac Timing: 125 seconds
Usage Comments UL94-5V Plenum Rated UL94-5V Plenum Rated DA/RA DA/RA Price 142.86 170.42 220.02 265.16
1/2, 3/4" Valves 1 to 1 1/2" Valves 1/2, 3/4" Valves 1 to 1 1/2" Valves
Small Individual Room Control (IRC) Electric Actuators provide floating or modulating control of V5852, V5862 two-way or V5853, V5863 three-way valves. Suitable for Excel/IRC system or other controllers providing specified signals. Magnetic coupling for torque limitation independent of voltage supply and self-adjustment of the closeoff port.
Part No. M6435A1004 Control Signal Floating, SPDT Feedback No No Yes Yes Stem Force (Lbf) 40.50 90 40.50 90 Comments
No mounting tools required. Small size allows installation in limited space of fan coil units, induction units, and small reheaters or recoolers. Visual position indication (red pin).
Use with 1/2 in. and 3/4 in. V58XX Cartridge Globe Valves 1 to 1 1/2 in. V58XX Cartridge Globe Valves 1/2 in. and 3/4 in. V58XX Cartridge Globe Valves 1 to 1 1/2 in. V58XX Cartridge Globe Valves
Floating, SPDT M6435A3000 M7435F1001 0-10 or 2-10 Vdc Modulating M7435F3007 0-10 or 2-10 Vdc Modulating
WATER
Controls central heating and/or cooling systems, fan coil systems, radiators and convectors. Depending on the model selected, it can be controlled by either a low or line voltage spst or spdt or floating controller such as a room thermostat, Aquastat control, or flow switch.
2-WAY , CARTRIDGE CAGE, WATER
Pressure ratingsStatic: 300 psi Burst: 1,500 psi Use with VCXXXXZZ actuator
3-WAY , CARTRIDGE CAGE, WATER
VCZAA1100 Connection (In.) Part No. VCZAA1100 VCZBB1100 VCZAL1100 VCZAM1100 VCZAR1100 VCZAS1100 Nom. Size 1/2 1/2 3/4 3/4 1 1 Type Sweat FPT FPT Sweat FPT Sweat Flow (Cv) 3.2 3.2 4.7 4.6 6.6 6.6 Price 58.70 63.90 92.00 83.16 132.74 124.18
VCZNB6100 Connection (In.) Part No. VCZNB6100 VCZMA6100 VCZMK6100 VCZML6100 VCZMR6100 VCZNE6100 Nom. Size 1/2 1/2 3/4 3/4 1 1 1/4 Type FPT Sweat FPT Sweat FPT Sweat Flow (Cv) 3.7 3.8 6.6 5.9 8.6 9.0 Price 77.48 71.74 113.12 98.62 152.32 166.94
988
HEATING
ACTUATOR
VC2111ZZ11 Part No. VC4011ZZ11 VC6831ZZ11 VC6934ZZ11 VC7934ZZ11 VC8114ZZ11 VC8714ZZ11 Voltage (Vac) 120 24 24 24 24 24 Timing (Sec.) 6 120 120 120 6 6 Type Control 2-Wire + Com 3-Wire 3-Wire 3-Wire 2-Wire 2-Wire + Com Signal SPST SPDT, Floating SPDT, Floating 0-10 Vdc Modulating SPST SPST Aux. Switch No Yes No No No Yes Price 95.58 205.34 160.64 252.10 72.84 91.78
2 WAY , ZONE
ERIE POPTOP
For zoning hydronic systems up to 50 psi 2-wire and 3-wire, 24V valves with screw terminal wiring panel and auxiliary switch Maximum water temperature: 240F, maximum system pressure 50 psi
2 WAY , ZONE, 2-WIRE
Nominal Tubing Part No. 1361102 1361103 1361104 ODF (In.) 3/4 1 1 1/4 Flow (Cv) 23.5 37.0 42.2 Price 291.14 305.26 341.12
The Erie PopTop actuator is specifically designed for use with Erie's valve body. The valve actuator can be installed after the valve body is installed onto the fan coil, radiation or air handler. The PopTop features the reliable synchronous motor driven spring return operation proven in millions of Erie valves. The PopTop actuator mounts directly onto the body quickly and easily without the need for linkages and calibration.
ACTUATOR, 2 POSITION, VT SERIES
MOTOR, REPLACEMENT
VT2212 Part No. 30A118A 30118B 30A118V Voltage 24 120 230 Price 66.36 66.36 75.60 Part No. VT2212 VT2213 VT2222 VT2223 VT2313 VT2315 VT2317 VT2323 VT2325 VT2327 VT2415 VT2417 VT2427 Connection Nom. Size 1/2 1/2 1/2 1/2 3/4 3/4 3/4 3/4 3/4 3/4 1 1 1 (In.) Type Sweat Sweat FPT FPT Sweat Sweat Sweat FPT FPT FPT Sweat Sweat FPT Flow (Cv) 2.5 3.5 2.5 3.5 3.5 5 7 3.5 5 7 5 7 8
Price 42.00 42.00 47.04 47.04 54.60 54.60 54.60 63.84 63.84 63.84 90.72 90.72 99.96
989
HEATING
VALVE, HYDRONIC CONTROL
3 WAY , ZONE ZONE VALVE
VT3212 Connection Nom. Size 1/2 1/2 1/2 1/2 3/4 3/4 3/4 3/4 3/4 3/4 3/4 3/4 1 1 1 (In.) Type Sweat Sweat FPT FPT Sweat Sweat Sweat FPT FPT FPT IFL1 IFL1 Sweat Sweat FPT Flow (Cv) 3 4 3 4 4 5 7 4 5 7 3 4 5 7 7.5
Part No. VT3212 VT3213 VT3222 VT3223 VT3313 VT3315 VT3317 VT3323 VT3325 VT3327 VT3342 VT3343 VT3415 VT3417 VT3427
1
Price 54.60 54.60 59.64 59.64 69.72 69.72 69.72 76.44 76.44 76.44 59.64 59.64 105.00 105.00 112.56
Taco zone valves permit accurate temperature control of individual rooms or groups of rooms in residences or commercial buildings 570 which are heated or cooled hydronically. Beryllium copper metal bellows separate system water from the atmosphere for positive and leakproof operation. Exclusive heat motor functions silently. Saves energy; heat motor is not constantly energized while the valve is open.
Part No. 570 571 572 573 555050 Nominal Size (In.) 1/2 3/4 1 1 1/4 Length (In.) 3 1/8 3 3/8 3 5/8 3 7/8 Shipping Weight (Lbs.) 2.25 2.25 2.25 2.25 Price 250.38 215.48 268.60 386.52 158.00
Inverted Flare
Spring return actuators for VM2xxx and VM3xxx series valves. 0 to 10 Vdc or 4 to 20 mA output.
AP13A000
Magnetic clutch to maximize motor life and gear train Manual overide Position indicator
Part No. AP13A000 AP23A000 AP33A000 Application Spring Return, Normally Closed Spring Return, Normally Open Non Spring Return Voltage 24 24 24 Price 276.36 276.36 157.92
VA-7450 actuators provide on/off, floating, or proportional control in HVAC applications. The compact design of this actuator series makes it ideal for installations in confined locations, such as fan coil applications. Designed for easy mounting in the field, or can be ordered factory coupled to Johnson Controls VG4000 or VG5000 Series Zone Valves. Durable, heat-stabilized, plastic resin enclosure allows the actuator to be used in applications with fluid temperatures up to 203F Actuator can be mounted after the valve body is piped, simplifying installation and providing application flexibility LED light provides direct, visual indication of the actuator operating status
Part No. VA745010011 VA745290011 Description 24 VAC On/OFF or Floating Control Electric Valve Actuator 0 to 10 Vdc Proportional Control Electric Valve Actuator Price 301.88 236.24
990
HEATING
HYDRONIC CONTROL
ZONE PANEL, CIRCULATOR ZONE VALVE
The SR single and multiple-zone series control relays incorporate up to six double pole/single throw zone relays to provide a convenient and cost effective SR601 way to control a multi-zone hydronic system. All multi-zone models include the priority plus feature that overrides the priority function in the case of a priority zone malfunction for freeze protection. Domestic hot water priority zone Zone Link for priority extension Zone Trak for status indication Contact rating: 10 Amp
Part No. SR100 SR301 SR6011 EXP10
1
Number of Zones 1 3 or 2/1 Priority 4 or 3/1 Priority 1 Zone Expansion for SR601 or Replacement Relay for All
Tranformer VA 10 15 25
Expandable to 6 zones
The VL500 with the exclusive Zone Link, Zone Trak and Priority Plus systems control up to five zone valves, an indirect heating system, a circulator and boiler control all in one controller. Domestic hot water priority zone Contact rating: 10 Amp Control transformer: 75 VA
Part No. VL500 Description 5 or 4/1 Priority Zone Control Price 424.20
Taco switching relays combine clearly labeled PC board layouts with advanced features that allow for total system customization. External indicator lights provide instant diagnostic feedback, making a snap of service calls or new installation start-ups. All switching relays are UL and CSA listed, use standard ice cube replaceable relays and are compatible with conventional and programmable thermostats. Features: External Indicator Lights Switchable Priority Simplified Wiring Fully Enclosed Snap-Out Relays Fuse Protected Isolated End Switch Contractor Friendly PC Board Layout Universal Thermostat Compatibility 24 Volt Power Input or Output Terminal Extended 3 Year Warranty Additional -EXP Features: Plug-in PowerPort Card Slots Add-on Power Control Plug Expandable to 20 Zones Interface with -EXP Zone Valve Controls
Part No. SR502 SR503 SR504EXP SR506EXP Number of Zones 2 with Priority 3 with Priority 4 with Priority, 3 Power Ports 6 with Priority, 3 Power Ports Contact Rating (Amps) 15 Amp 15 Amp 20 Amp 20 Amp Price 278.74 301.86 485.34 525.98
If you can't find it here, let us know. United Refrigeration specializes in locating hard to find parts
Price 679.36
Microprocessor-based control designed to regulate the supply water temperature from a single boiler based on the outdoor temperature. Standard functions include warm weather shut down, minimum boiler supply temperature setting, and a starting water temperature setting. Power supply: 24 VAC 3 VA (powered by -EXP control) Relays: 24 V (ac) 5A, pilot duty, 240 VA
991
HEATING
HYDRONIC CONTROL
ZONE VALVE CONTROL
Taco Zone Valve Controls work with two-, three-, or four-wire zone valves. Fully fuse protected, they also include two isolated end switches and a builtin priority switch. The contractor friendly PC board layout eliminates the problems caused by incorrect wiring and the unfinished look of conventional zone valve installations. The sturdy screw connections add additional reliability, while the external indicator lights provide instant diagnostic feedback, reducing installation time. Features: External Indicator Lights Switchable Priority Simplified Wiring Extra Set of Dry Contacts Contractor Friendly PC Board Layout Universal Thermostat Compatibility UL and CSA Approved Extended 3 Year Warranty Additional-EXP features: Two Plug-In PowerPort Card Slots One Add-On Power Control Plug Expandable to 20 Zones Interface with -EXP Switching Relays
Part No. ZVC403 ZVC404 ZVC406EXP Number of Zones 3 4 with Priority 6 with Priority, 2 Power Ports Tranformer VA 40 40 80 Price 211.50 262.62 481.14
Immersion type Aquastat controller and oil burner primary control provides high limit and low limit/circulator control for oil-fired hydronic heating R8182D1111 systems. Control rangeHigh limit SPST: 130240F Differential: 10F, fixed Low limit, circulator SPDT: 110220F Differential: 1025F 120 Vac
Insulation Spud Capillary Depth Part No. R8182D1079 R8182D1111 R8182H1070 (In.) 1 1/2 1 1/2 1 1/2 Size (In.) 3/4 3/4 3/4 Length (Ft.) None None 5 Includes Well Adapter, Vertical Case Well Adapter, Horiz. Case Horiz. Case Price 912.28 912.28 934.28
SWITCHING RELAY
UNIVERSAL
The R7284 Electronic Oil Primary is a line voltage, safety rated, interrupted and intermittent ignition oil primary R7284U1004 control for residential oil fired burners used in boilers, forced air furnaces and water heaters. Used with a cad cell flame sensor, it operates an oil burner, spark igniter, and optional oil valve. The control works with a low voltage and optional high voltage thermostat. The primary controls fuel oil, senses flame, controls ignition spark (either interrupted or intermittent) and notifies through the EnviraCOM bus a remote alarm circuit when in lockout. Can be used with both hydronic and forced air systems.
Timing Safety Part No. R7284B1024 Switch (Sec.) 15 Diagnostics Display Using LED only F.L. Amps (@ 240 Vac) 3.7 3.7 Price 141.94 106.02
The R8845U Universal Switching Relay with 24V controller provides intermediate switching of line- and low-voltage devices from a line- or lowvoltage controller. Replaceable, socketed relays Two troubleshooting LEDs Push-to-test button Relays can be used with external 24 Vac or 24 Vdc supply, linevoltage control, or with internal 24V transformer
Part No. R8845U1003 Description Switching Relay Price 125.30
PRIMARY
668430
Replaces intermittent ignition KwikSensor cad cell relays on oil burner systems with 15, 30 or 45 second safety timing. Certain types have unique signal-lite feature which glows whenever safety lockout occurs.
Price 229.94
992
HEATING
PROTECTOR RELAY FLAME DETECTOR
R8184G4009
Provides automatic, nonrecycling control of an intermittent ignition oil burner system. Controls oil burner, oil valve (if desired) and the ignition transformer in response to a call for heat
Voltage: 120 Vac Includes LED lockout indication and manual trip safety switch for shutdown during servicing
Timing Safety Part No. R8184G4009 R8184G4066 Switch (Sec.) 45 15 F.L. Amps (@ 240 Vac) 3.7 5.0 Price 161.18 217.58
Photoconductive flame sensing device for sequencing oil burner systems. On flame failure, the light sensitive cadmium sulfide cell, in conjunction with flame sensing circuitry, causes the Protecto-relay control to shutdown the main oil burner Use with oil primary controls, i.e.: R4166, R4184, R8182, R8184, R8185 and R8404
Part No. C554A1463 Description Flame Detector, 5 Bracket Styles Price 34.96
Operates the oil burner and oil valve (if desired) in response to a call for heat from a low voltage control circuit. Includes transformer Primary voltage: 120 Vac Secondary voltage: 26.5V Contacts: 3.7 F.L. Amp @ 240 Vac
Part No. R8184M1051 Timing Safety Switch (Sec.) 45 Price 274.06
V4046B1049
For on/off control of oil flow to domestic oil burner equipment. Connection: 1/8" FPT Capacity: 535 GPH
Pressure Range Orifice Size (In.) .043 .043 Voltage 120 120 Price 143.46 130.30
PROTECTORELAY/ PYROSTAT
TESTER
PROGRAMMER
One-piece, stack-mounted oil burner primary controls that cycle the burner on and shut down the burner on flame loss or system malfunction. RA116A1055 Manual reset of safety switch required after ignition failure completely shuts off main burner Includes manual trip safety switch to assure burner shutdown during servicing Input voltage: 120V Contact rating: 3.7 F.L. Amp @ 240 Vac
Ignition Part No. RA116A1055 RA117A1047 Type Intermittent Interrupted Ignition Rating (Vac) 360 550 Price 367.66 386.08
Provides quick operational check of most Honeywell BC7000, R4140 and R4150 programmers It will operationally check the R7795 if used with 198355A adapter.
Part No. FSP5004 Description Programmer Tester Price 3001.42
PRIMARY CONTROL
Provides quick operational check of most Honeywell RA890 or R4795 non-programming primary controls.
FLAME DETECTOR
Solid state electronic flame detector which uses light intensity to sense the presence of a flame in oil burning heating equipment. Cadmium sulfide type
Part No. 956154 Lead Length (In.) 60 Description Universal, 6 Brackets Price 34.32
Price 1380.06
993
HEATING
FLAME CONTROL
PRIMARY CONTROL PRIMARY CONTROL, FULL FUNCTION
Provides solid state, electronic flame safeguard protection for commercial and industrial single or dual fuel burners. Use with rectification or ultraviolet type flame detectors, depending on the interchangeable plug-in amplifier being used. R7289A, R7290A amplifier and ST71A timer required components Power supply: 120 Vac
Part No. R4795A1016 Description Primary Control System Price 2649.74
Provides solid state, electronic flame safeguard protection for commercial and industrial single or dual fuel burners. Includes flame signal amplifiers that are color coded; purple for ultraviolet and green for rectification. Requires a plug-in prepurge timer of 1.5, 7, 10, 30, 60 or 90 seconds. Includes line voltage airflow switch to prove airflow from the start of prepurge through the run period. Requires ST795A plug-in prepurge timer Requires Q795A mounting sub base
Pilot Part No. R7795A1001 Flame Detection Price 2644.82 Function Type With Sensor Intermittent UV C7027A, C7035A Minipeeper
Solid state, plug-in units allow use of rectification or ultraviolet flame detection. Use with R4795A, D flame safeguard primary controls and appropriate flame detector. Amplifiers are not self-checking Use with gas, oil or coal Rectifying Photocell Flame Rod, UV (Purple Peeper)
Flame Failure Part No. R7289A1004 Type Rectification Color Green Response (Sec.) 3 Price 765.40
RA890F1270
Primary control provides solid state, electronic flame safeguard protection for industrial and commercial single or dual fuel burners. 3 second response time recommended for nonrecycling ignition cutoff service, except where noted. Uses rectification principle of electronic flame detection.
Supply Voltage Safety Switch Timing (Sec.) 15 15 30 30 15 (Vac) 120 120 120 120 120
Relights once after flame failure in attempt to reestablish pilot before lockout. Safe-start check prevents start-up if flame-simulating failure occurs in flame detector circuit. Includes built-in protection against ignition crossover in flame rod systems.
Flame Failure Response (Sec.) 0.8 3.0 0.8 3.0 0.8 Price 2440.16 2479.22 2440.16 2479.22 2498.28
Primary control provides solid state, electronic flame safeguard protection for industrial and commercial single or dual fuel burners. Designed for interrupted ignition with intermittent pilot on gas burners, and interrupted or intermittent ignition on oil burners.
Supply Voltage Part No. RA890G1229 RA890G1260 (Vac) 120 120 Safety Switch Timing (Sec.) 15 15
Use with a C7027, C7035 or C7044 minipeeper ultraviolet flame detector for flame sensing. Relights once after flame failure in attempt to re-establish pilot before lockout.
994
HEATING
FLAME CONTROL, 7800 SERIES
PROGRAMMER
Microprocessor-based integrated burner control for automatically fired gas, oil, coal or combination fuel single burner applications. Provides safety, functional capability and features beyond conventional controls.
RM7840G1014 Part No. RM7800G1018 RM7800L1012 RM7800M1011 RM7840E1016 RM7840G1014 RM7840L1018 RM7840M1017 Description Control w/Display Control w/Display Control w/Display Relay Module, No Display Relay Module, No Display Relay Module, No Display Relay Module, No Display Frequency 60 Hz 50/60 Hz 60 Hz 50/60 Hz 60 Hz 50/60 Hz 60 Hz
Functions include automatic burner sequencing, flame supervision, system status indication, system or self-diagnostics and trouble-shooting. Only available in NJ, DE, Eastern-Southern NY/PA.
Replaces BC7000L; PM720G BC7000L; PM720L BC7000L; PM720M R4140G R4140L R4140M Price 3810.30 4021.58 3485.56 3409.12 2837.88 3380.64 2515.18
TIMING SEQUENCE
Pilot Flame Establishing Period (MFEP) 4 or 10 sec. 4 or 10 sec. 4 or 10 sec. 4 or 10 sec.
3
Part No. RM7800E, RM7840E1 RM7800G, RM7840G RM7800L, RM7840L RM7800M, RM7840M
1
Standby
2 2 2 2
Purge
3 3 3 3
Main Flame Establishing Period (MFEP) 10 or 15 sec. 10, 15 or Intermittent 10, 15 or Intermittent 10 sec. or Intermittent
Run
2 2 2 2
PROGRAMMER
Microprocessor-based integrated burner control for automatically fired gas, oil, coal or combination fuel single burner applications. Provides safety, functional capability and features beyond conventional controls. Uses existing subbase for easier installation
Functions include automatic burner sequencing, flame supervision, system status indication, system or self-diagnostics and trouble-shooting. Requires ST7800 purge timer and appropriate R787xx amplifier to complete the replacement Purge time determined by card selected
Price 3738.66 3738.66 4681.36 4681.36 3294.10
TIMING SEQUENCE
Pilot Flame Establishing Period (MFEP) 4 or 10 sec. 4 or 10 sec. 4 or 10 sec. 4 or 10 sec. Main Flame Establishing Period (MFEP) 10, 15, 30 sec. or int. 10, 15, 30 sec. or int. 10 or 15 sec. 10 sec. or Intermittent
Replaces R4140G w/ preignition interlocks BC7000L, PM720G, R4140G w/ start interlocks R4140L BC7000L; PM720L BC7000L; PM720L
995
HEATING
FLAME CONTROL, 7800 SERIES
PROGRAMMER
Microprocessor-based integrated burner controls. It is a plug in replacement of Fireye M series using existing Fireye wiring subbase Functions provided by the R7120M include automatic burner sequencing, flame supervision, system status indication, system or self-diagnostics and troubleshooting.
Part No. R7120M1001 R7120M1019 Description Burner Control Module, Intermittent Burner Control Module, Interrupted
Require ST7800 Purge Timer and appropriate R78XX Amplifier to complete the replacement. PrePurge: Determined by ST7800A Purge Timer Card PostPurge: programmed with S7800A1142 display 4 or 10 second pilot flame establishing period Only available in NJ / Eastern-Southern NY. Call 914-592-5555 to order.
Replaces Fireye M Intermittent Fireye M Interrupted Price 866.60 866.60
Microprocessor-based integrated full-function primary burner control for automatically fired gas, oil, or combination fuel single burner applications. Provides level of safety, functional capability and features beyond conventional controls. Only available in NJ, DE, Eastern-Southern NY/PA.
RM7890C1005 Initiate Time (Sec.) 10 10 10 10 Pilot Flame Establishing Period (Sec.) 4, 10, 30 30 Fixed N/A 4, 10
Comments Replaces RA890F , G, H Replaces RA890F , G, H For Standing Pilot, Replaces RA890F , G, H Includes Programmable Valve Proving Switch Check Feature and Blinking LED Fault Annunciation
Microprocessor-based integrated full-function primary burner control for automatically fired gas, oil, or combination fuel single burner applications. Provides level of safety, functional capability and features beyond conventional controls. Only available in NJ, DE, Eastern-Southern NY/PA.
RM7840G1014 Flame Establishing Period Part No. RM7895A1014 RM7895B1013 Type Intermittent w/AFSC Interrupted w/o AFSC Replaces R7795E, F Initiate Standby
1 1 1
Purge
2 2 2
Main No No 10 sec.
RM7895C1012
1
Microprocessor-based integrated full-function primary burner control for automatically fired gas, oil, or combination fuel single burner applications. Provides level of safety, functional capability and features beyond conventional controls. Only available in NJ, DE, Eastern-Southern NY/PA.
Flame Establishing Period Part No. RM7896A1012 RM7896C1010 Type Intermittent Intermittent Initiate 10 sec. 10 sec. Pilot 4 or 10 sec. 4 or 10 sec. Main Intermittent 10 Sec Airflow Switch Check (AFSC) No No Main Valve (DMV) No Yes Price 1510.18 1663.34
996
HEATING
ON-OFF PRIMARY WITH SHUTTER DRIVE AND PROGRAMMABLE POST PURGE
Microprocessor-based integrated full-function primary burner control for automatically fired gas, oil, or combination fuel single burner applications. Provides level of safety, functional capability and features beyond conventional controls. Includes blinking LED fault annunciation feature Only available in NJ, DE, Eastern-Southern NY/PA
Part No. RM7897A1002 Type Selectable Pilot Flame Establishing Period (Sec.) 4 or 10 sec. Purge PrePurge Determined by ST7800A Purge Timer Card PostPurge Programmed with S7800A1142 Display (Not Provided) Price 921.80
WIRING SUBBASE
Burner, panel or wall mount sub bases for 7800 Series relay modules and S7830A expanded annunciator. 22 terminals Only available in NJ, DE, Eastern-Southern NY/PA.
Q7800A1005 Part No. Q7800A1005 Q7800B1003 Q7800F1004 Q7800F1012 Description UniversalPanel Mount UniversalBurner, Wall Mount AdapterRA890 AdapterR4795 Price 50.84 50.84 199.02 199.02
KEYBOARD DISPLAY
Provides current status of burner sequence, timing information, hold information and lockout information, as well as selectable or preemptive messages. Only available in NJ / Eastern-Southern NY. Call 914-592-5555 to order.
Description Display Module, English Display Module for Valve Proving Setup, English
Usage RM7800, RM7840, RM7838 RM7800, RM7840, RM7838, RM7890, RM7897, RM7898
Solid state plug-in amplifiers that respond to flame detector inputs to indicate the presence of flame when used with 7800 Series relay modules. Only available in NJ, DE, Eastern-Southern NY/PA
R7848A1008 Part No. R7847A1025 R7847A1033 R7848A1008 R7848B10061 R7849A1015 R7849A1023 R7851B1000 R7851B1018 R7852A1001 Pilot Type Rectification (Green) Rectification (Green) Infrared (Red) Infrared (Red) UV (Purple) UV (Purple) Optical (White), Ampli-Check Optical (White), Ampli-Check Infrared (Red/White) Flame Failure Response (Sec.) 0.8 or 1.0 2.0 or 3.0 2.0 or 3.0 2.0 or 3.0 0.8 or 1.0 2.0 or 3.0 2.0 or 3.0 0.8 or 1.0 2.0 or 3.0 2.0 or 3.0 Type Fuel Gas, Oil Gas, Oil Gas, Oil, Coal Gas, Oil, Coal Gas, Oil Gas, Oil Gas, Oil, Coal Gas, Oil, Coal Gas, Oil, Coal Gas, Oil, Coal Price
UV (Purple) Dynamic Self-Check R7861A1026 1 Circuitry test amplifier 12 times/minute, shuts down on failure
997
HEATING
FLAME CONTROL, 7800 SERIES
FIRST-OUT ANNUNCIATOR PURGE TIMER
Microprocessor-based expanded annunciator to support the 7800 Series relay modules for first-out annunciation, sequencing, system or self-diagnostics and troubleshooting. Front panel LED array-arranged to indicate flow of line-voltage through string of limits, controls and interlocks Only available in NJ, DE, Eastern-Southern NY/PA.
ST7800A1013
Provides prepurge timing for select 7800 Series relay modules. Use with RM7800, RM7840, RM7895, RM7838 relay modules Only available in NJ, DE, EasternSouthern NY/PA.
Prepurge Part No. Timing (Sec.) 7 10 30 60 90 Price 93.52 93.52 93.52 93.52 93.52 ST7800A1013 ST7800A1021 ST7800A1039 ST7800A1054 ST7800A1062
Price 1300.68
The C437D,E Series 2000 Gas Pressure Switches are pressure actuated switching devices used in industrial gas system applications for safety shutoff, pressure C437E control, and differentialpressure control. All Series 2000 models have MicroSwitch snap switches to open or close a circuit on pressure rise or drop.
Part No. C437D2003 C437D2011 C437D2029 C437E2002 C437E2010 C437E2028 C437E2036 Pressure Range 1 to 26 in. wc 1/2 to 5 psi 1 to 10 psi 1 to 26 in. wc 1/2 to 5 psi 1 to 10 psi 0.5 to 5.5 in. wc 5.0 psi 15.0 psi 30.0 psi 5.0 psi 15.0 psi 30.0 psi 3.0 psi
Pipe Connections High Pressure: 1/2 in. NPT internal thread Low pressure: 1/8 in. NPT internal thread 240 Vac: 5.1 AFL, 5.0 A resistive SPST switch, non-mercury Manual Reset
Differential 1 3/4 in. wc 1/2 psi 1 psi 1 3/4 in. wc 1/2 psi 1 psi 0.25 in. wc Switch Break on Rise Break on Rise Break on Rise Break on Fall Break on Fall Break on Fall Break on Fall Price 392.98 392.98 392.98 392.98 392.98 392.98 392.98
For use with natural gas, liquid propane (LP) gas, or air. Diaphragm-actuated safety-limit switch.
Part No. C6097A1012 C6097A1038 C6097A1053 C6097B1002 C6097B1028 C6097B1051 Pressure Range 3 to 21 in. wc 12 to 60 in. wc 3 to 21 in. wc 12 to 60 in. wc 3 to 21 in. wc 1.5 to 7 in. wc Differential Pressure 2.4 to 4.2 in. wc 10 to 12 in. wc 0.24 to 0.48 in. wc 10 to 12 in. wc 2.4 to 4.2 in. wc 1.1 to 1.4 in. wc
Surge orifice. Integral vent limiter on all models. Contact ratings: 3 FLA @ 240 Vac
Action Break on Fall Break on Fall Break on Fall Break on Rise Break on Rise Break on Rise
Switch Manual Reset Manual Reset Auto Recycle Manual Reset Manual Reset Manual Reset
998
HEATING
FLAME SENSOR
FLAME ROD HOLDER
FLAME DETECTOR
PURPLE PEEPER ULTRAVIOLET
Used to apply flame rod in gas-fired system controlled by rectification-type flame safeguard control. Use with pressurized fire boxes Order flame rod separately
Price 462.52
Solid state electronic flame detectors for use with Honeywell flame safeguard controls and amplifiers. Sense ultraviolet radiation produced by combustion of gas, oil, coal or other fuels. Use with Honeywell rectification-type flame safeguard controls EXCEPT Dynamic Self Check Models. Dynamic Self Check controls are R4075C, D, E; R4138C, D; R4140, BC7000 with R7247C amplifier, BCS7700 with R7747C amplifier or 7800 series with R7847C amplifier. Enclosure meets NEMA 4 standards
Power Supply Part No. C7012A1145 (Vac) 120 Pipe Mounting Size 3/4" FPT Price 2464.86
C7009A1025
Subminiature "spark plug" type flame rod holder with flame rod. Use on industrial flame-retention gas burner nozzles
Works with Honeywell flame safeguard controls requiring rectification- type flame detector Flame rod can be cut to desired length Mounting: 1/8" NPT male
Part No. C7009A1009 C7009A1025 Length (In.) 4 12 Price 154.34 199.58 C7027A1049
MINIPEEPER ULTRAVIOLET
Compact flame detector for use with flame safeguard controls with ultraviolet amplifiers. Mounts on a 1/2" sighting pipe by using an integral collar
Lead wire length: 6' Ambient temperature: 0 to 215F Ambient temperature for C7027A1031: -40 to 215F
Part No. C7027A1023 C7027A1031 C7027A1072 C7027A1049 C7027A1080 Connects Romex Connector, Low Temperature 1/2" Spud Connector 1/2" Spud Connector (Included) Romex Connector Heat Block & Bushing, Replace Fireye UV2 Price 206.08 228.46 228.46 206.08 256.14
Miniature "spark plug" type flame rod holder with threaded base, snap-on cover and Kanthal A-1 flame rod. C7008A1182 Use with Honeywell flame safeguard controls requiring rectification-type flame detection Comes in several different lengths and can be cut to exact desired length. Mounting: 1/4" NPT male
Part No. C7008A1174 C7008A1182 Length (In.) 12 24 Price 243.68 361.76
COMPACT
DYNAMIC UV
Dynamic self-checking flame detector used with R7861 Dynamic Self-check Amplifiers for sensing the ultraviolet radiation generated by the combustion of gas, oil, or other fuels. Can be mounted horizontally, vertically or at any angle in between. Field replaceable ultraviolet sensing tube and quartz viewing window. Two detectors may be wired in parallel to reduce nuisance shutdowns in difficult flame sighting applications. Protective heat block built into mounting flange.
Price 1943.06
Compact flame detector for use with flame safeguard controls with ultraviolet amplifiers. Only available in NJ, DE, EasternSouthern NY/PA.
999
HEATING
FLAME DETECTOR
INFRARED
GAS PILOT
FLAME RECTIFIER
The C7915 Flame Detectors include a lead sulfide photocell that is sensitive to the infrared radiation emitted by the combustion of fuels such as natural gas, oil, and coal. Used for combination or dual-fuel applications. Detects pilot and main flame. Mounts quickly and easily on a standard 3/4 in. sighting pipe. Works where flame rod or rectifying photocell mounts are difficult to apply. The C7915 includes 50019469-001 Bushing with magnifying lens, photoconductive lead sulfide cells 32007255-001, orifice, heat block and reducer bushing Used With Flame Amplifiers: R7852
Part No. C7915A1028 Description Infrared Compact Flame Detector Use With R7852 Price 476.90
Combination rectifying flame rod and pilot burner for use with suitable electronic relay on industrial or commercial gas burners or gas pilot Q179A1076 ignited oil burners. Primary-aerated type burner is equipped with stainless steel fins to stabilize flame and provide correct flame rod area to ground area ratio for maximum flame current. Tip Styles
45 RH
45 LH
45 Y
45 T
MINIPEEPER ULTRAVIOLET
Part No. Q179A1001 Q179A1035 Q179A1050 Q179A1076 Q179A1092 Q179A1118 Q179B1042 Q179B1109
Detect the ultraviolet radiation emitted by combustion flames. The flame detectors are used with Honeywell flame safeguard controls to provide flame supervision for gas, oil, or combination gas-oil burners. Properly installed the flame detectors are pressure rated for 5 psi. Flame detector is used with only the R7851B Flame Amplifier and the 7800 SERIES controls. Has an integral collar threaded (internal 1/2-14 NPSM) for mounting on a one-half inch sight pipe. Application: Gas, Oil, or combination burners-intermittent operation only (burner cycled at least once each 24 hours).
Tip Style I 45 RH T 45 Y 45 T 45 LH T 45 LH
Application Intermittent Ignition Intermittent Ignition Intermittent Ignition Intermittent Ignition Intermittent Ignition Intermittent Ignition Continuous Pilot Continuous Pilot
MINIATURE
Price 266.68
Gas pilot burner assemblies prove pilot flame on industrial or commercial gas burners or gas pilot-ignited oil burners. Combination pilot burner and rectifying flame rod flame detector. With ignition electrode; suitable for use on interrupted or intermittent electrically ignited gas pilot applications. Use with Q624 or other suitable ignition transformer.
Part No. Mounting End Wing Span (In.) 1 Price 181.16 Q179C1009
Detects the visible light emitted by fuel oil combustion flames. The C7962B Detector is used with Honeywell Flame Safeguard controls to provide fuel oil flame supervision in commercial and industrial burners. Used with 7800 SERIES Flame Safeguard controls; R7851B flame amplifier Has an integral collar threaded (internal 1/2-14 NPSM) for mounting on 1/2 inch sight pipe. Application: Commercial, industrial oil burners
The H17 is a replacement automatic pilot valve particularly adaptable to small appliances. Gas will flow to both H17DB5 main and pilot burners when reset button is depressed. Pilot gas taken from main line within control. The control shuts off both main and pilot gases.
Connection Part No. Pilot (In.) 1/8-27 NPT 1/8-27 NPT 1/8-27 NPT Capacity BTUH/Hr. @ 1" P 75,000 125,000 200,000 Low Dropout (mA) 50 50 50
Price 395.86
1000
HEATING
AUTOMATIC MANUAL SHUTOFF SHUTOFF
H43GA3
Designed for use on appliances such as room heaters, wall furnaces, etc. 170,000 BTU/hr. @ 1" P capacity.
Provides on/off control of natural, LP and manufactured gases to pilot burners in industrial and commercial applications.
V4046C1005 Pipe Size FPT (In.) 1/8 1/4 3/8 1/8 1/4 1/4 3/8 Capacity (CFH) 20 55 67 20 20 55 67
Part No. Connection Main Part No. H43BA2 H43GA3 FPT (In.) 1/2 1/2 Pilot (In.) 1/4 cc 1/4 cc Pilot Shutoff Adjustment Handle Yes 1/4" Sq. Rod No Price 307.34 307.34 V4046C1005 V4046C1047 V4046C1054 V8046C1006 V8046C1014 V8046C1022 V8046C1030
Voltage 120 Vac 120 Vac 120 Vac 24 Vac 24 Vac 24 Vac 24 Vac
The L61 and L62 Series BASO pilot switches are for use on all gas-fired, standing pilot equipment that requires main burner shutoff when the pilot is L62GB3 extinguished. L61LL1 and L62AA5 are not 100% shutoff (suitable for natural gas only)
Part No. L61LL1 L62AA5 L62GB3 Reset Automatic Manual Manual Shutoff No No Yes Switch SPDT SPST SPST F.L. Amps (@ 240V) 4 A, 240 Vac 3 A, 250 Vac 4 A, 250 Vac Price 441.62 183.52 188.50
AUTOMATIC
Connection Replaces Electrical FPT (In.) W/R Voltage Amps Connection 1/2 2509A-254 120 0.05 30" leads H91DA11 1/2 2509-254 24 0.3 30" leads H91DG13 3/4 2509-256 24 0.4 30" leads H91LG15 3/4 2509A-256 120 0.08 30" leads H91LA2 3/4 24 0.3 1/4" male spade H91RG1 3/4 120 0.05 30" leads H91RA4 1 2509-258 24 0.4 30" leads H91MG9 1 2509A-258 120 0.4 30" leads H91MA5 1/4 cc 24 0.3 1/4" male spade H91WG1 Part No.
Price 172.10 172.46 263.96 261.86 246.54 251.72 264.62 265.18 156.36
The H15 Series control shuts off both main and pilot gas. Pilot gas is taken either from within the control or from the main line upsteam of the valve. Gas H15DH3 will pass only to the pilot burner while the reset button is depressed. Some models include a rotor pilot "B" valve with an adjustable stop to maintain a constant open position. Capacity BTUH/Hr. @ 1 DP: 402,000
Part No. H15DA31 H15DH3
1
Connection Main FPT (In.) Pilot (In.) 3/4 1/8-27 NPT 3/4 1/4 cc
2
The H91 Series are 2-wire, electrically operated shutoff valves that automatically open and close on a demand signal from a thermostat or H91WG1 other controlling device. Those indicated as White Rodgers replacements replace their compression spring closing and soft seat construction features. These valves can be used for all gas-fired appliances with a maximum operating pressure of 1/2 psi. H91W connections: 1/4" compression Permissible ambient temperature -40 to +175F (-40 to +80C) CSA -40 to +140F (-40 to +60C) UL Approvals : CSA (AGA/CGA) Certificate 229521-1656058 [All] Australian Gas Association Certificate 4235 [H91D, H91L, H91M only] UL Recognized File MH5939 [H91D, H91L, H91W only]
V4295/V8295 solenoid gas valves control the flow of natural and LP (liquefied petroleum) gases and are suitable for use on furnaces, ovens, atmospheric burners, commercial water heaters, rooftop make-up air units, power burners and commercial/ industrial boilers. Body Material: Die cast aluminum Valve Timing: Open/Close less than 1 second; positive close off Ambient: -40 F to 145 F (-40 C to 60 C) APPROVALS: Underwriters Laboratories, Inc., CSA, Factory Mutual (all, except 1" to 3" 2 psi version), CSD-1 and IRI acceptable
Part No. V4295A1098 V4295A1106 V4295A1114 V4295A1122 V4295A1130 V4295A1148 V8295A1016 V8295A1024 V8295A1032 V8295A1040 V8295A1057 Pipe Size FPT (In.) 3/8 1/2 3/4 1 1 1/4 1 1/2 1/2 3/4 1 1 1/4 1 1/2 Capacity (CFH) 210 210 610 825 1950 2270 250 645 790 1450 2190 Coil Voltage 120 120 120 120 120 120 24 24 24 24 24 Price
251.90 338.62 425.68 459.70 584.68 176.42 201.04 277.14 331.60 467.08
1001
HEATING
VALVE, GAS CONTROL
DIAPHRAGM INDUSTRIAL
V88A1691
Solenoid-operated diaphragm valves provide slow opening and fast closing for controlling fuel gases. Use with LP, natural or manufactured gases
Pipe Size FPT (In.) 3/4 3/4 1 1 1 1/4 1 1/4 1 1/2 1 1/2 2 2 1/2 3 AGA Capacity (CFH) 668 668 1021 1021 2100 2100 2400 2400 4178 5100 5562 Max. Sustained Pressure (psi) 1/2 1 1 1 1 1/2 1 1/2 1 1 1 Part No. Power (Vac) 24 24 24 120 24 120 24 24 24 24 24 Price 243.08 283.82 307.86 307.82 402.72 357.02 443.48 393.82 759.88 927.66 1534.04 V5055A1004 V5055A1038 V5055A1053 V5055B1234 V5055B1002 V5055B1010 V5055B1028 V5055B1069 V5055C1059 V5055C1000 Application
Safety shutoff valves used with V4055, V4062 and V9055 fluid power actuators to control gas flow to commercial and industrial burners. Use with natural or LP gases
Pipe Size FPT (In.) 1 2 3 3/4 1 1 1/4 1 1/2 2 1 1/2 2 AGA Capacity (CFH) 960 3620 5230 665 960 1406 1717 3620 1717 3620
Price 306.60 561.20 943.36 291.98 322.64 371.38 438.18 612.42 848.32 1022.08
Part No. V88A1659 V88A1667 V88A1675 V48A2334 V88A1683 V48A2177 V88A1691 V88A1634 V88A1709 V88A1717 V88A1725
Low Pressure On/Off (Quick Open Guide) Low Pressure On/Off Characterized Guide (Slow Increase Upon Opening) Low Pressure On/Off Double Seal
IVT BUTTERFLY
ACTUATOR, ON/OFF
Use with V5055 valve to control gas supply to commercial and industrial burners. V4055D1001, V4055D1043 on/off actuator includes Factory Mutual "Proof V4055A1007 of Closure" and Underwriters Laboratories, Inc. "Valve Seal Overtravel Interlock" switch. Meets Factory Mutual and Underwriters Laboratories, Inc. requirements when used with V5055C valve bodies. Low pressure. Supply voltage: 120 Vac
Part No. V4055A1007 V4055A1031 V4055A1098 V4055A1296 Opening Time (Sec.) 26 13 13 13 26 13 13 Damper Shaft No No Yes No Yes Yes No Internal Aux Switch No No No Yes, adjusted to 90 stroke No No No Price 658.90 711.68 711.68 797.30 721.42 770.90 770.90
The V5197A is a firing rate valve used to provide variable flow control of air, natural gas, liquefied petroleum (LP), and manufactured gases. The V5197A is actuated by a ML7999A or B firing rate motor that can be mounted directly on the valve. The V5197A is not applicable as a safety shutoff valve. The V5197A is specially designed to provide fine control of gas flow in applications where a high turn down ratio is required. The maximum flow adjustment screw on the bottom of the valve allows adjusting the maximum flow of gas through the V5197 while maintaining the linear modulating characteristics and stroke. The V5197A is part of the Honeywell Integrated Valve Train System that allows gas train components to be directly bolted together. For modulating applications that do not require final shutoff service of firing rate valve. Two downstream 1/4 in. NPT threaded pressure taps available. Accepts C6097 Pressure Switch mounted directly to flange (downstream pressure tap only). Visual position indicator. Pressure Ratings: 15 psi max (1 Bar)
Part No. V5197A1011 Application 2 to 3" Pipe Size Capacity (cfh) 16,900 at 3" Price 686.74
ACTUATOR, OFF/LOW/HI
Controls gas supply for commercial and industrial burners. Valve opens to low fire position when power is applied; valve opens all the way on demand. Use with V5055B, V5097B valve bodies, V5034, VE5000 Low pressure Supply voltage: 120 Vac
Part No. V4062A1008 V4062A1123 Opening Time (Sec.) 26 26 Internal Damper Shaft Aux Switch Yes No Yes with Return Yes Spring Installed Price 958.80 1158.78
1002
COMMERCIAL, VALVE
INDUSTRIAL THERMOSTAT
Single-stage Pressure Regulating Valve;These valves are used on boilers, unit heaters, duct furnaces, makeup air and rooftop heaters.
7551
Solenoid-operated diaphragm valves that combine the functions of safety shutoff and pressure regulation in a single unit. Valve body of die-cast aluminum with a straight-through pattern. Valve closes on power failure; recommended for final shutoff service. Electrical Connections: 1/4 in. (6 mm) spade terminals (quick connects). 30 in. (762 mm) leadwires and cover for electrical conduit connection provided. Pressure Ratings: 1/2 psi (3.4 kPa) Mounting: Upright (horizontal) Valve Type: Single-Stage, Slow Opening Valve Closing Time: 2 sec max
Type Connection Capacity Open Gas FPT (In.) (CFH) Time (sec) 1 1/2 FPT 780 to 2300 6 V8943N1039 NAT Part No. Volt 24 Price 533.44
OVEN CONTROL
INFINITE SWITCH
Infinite controls Uni-Kits include adaptors for screw- or palnut-type mounting. Kits include dial adaptors, allowing the customer's dial to be used. Contact rating: 15 amps @ 240 Vac Universal mounting
Two-way push-down to close (NO/PDTC) FPT connection Brass trim, equal % flow
Part No. VG7241ET VG7241GT VG7241LT VG7241NT VG7241PT VG7241RT VG7241ST Size (In.) 1/2 1/2 3/4 1 1 1/4 1 1/2 2 Flow (Cv) 1.8 4.6 7.3 11.6 18.5 28.9 46.2 Price 163.94 164.98 231.44 300.06 415.16 578.40 698.74
% Input at Low 5 5 5 5 5
Color Dial Included White None Black Black White Price 69.36 40.62 44.12 58.44 69.54
Two-way push-down to open (NC/PDTO) FPT connection Brass trim, equal % flow
Part No. VG7441ET VG7441GT VG7441LT VG7441NT VG7441PT VG7441RT VG7441ST Size (In.) 1/2 1/2 3/4 1 1 1/4 1 1/2 2 Flow (Cv) 1.8 4.6 7.3 11.6 18.5 28.9 46.2 Price
Reverse rotation
Switch: DPST, open rise Contact rating: 40.0 resistive amps @ 277 Vac
1003
COMMERCIAL, VALVE
WATER AND STEAM VALVE
The V5011N is a two-way threaded globe valve that controls steam, water, and glycol solutions (up to 50% concentration) in heating or cooling HVAC applications. The valve is used in two-position and modulating control systems. V5011N1000 and V5011N2000 valves are push down to close (NO/PDTC) V5011N3000 valves are push down to open (NC/PDTO) Direct coupled electric and pneumatic actuators for easy mounting Stroke: 3/4" Not suitable for combustible gases. Valves require a linkage and control motor; a direct-coupled actuator or pneumatic valve actuator to position the valve.
2-WAY , GLOBE, THREADED, PDTC
Size Part No. V5011N1024 V5011N1032 V5011N1040 V5011N1057 V5011N1065 V5011N1073 V5011N1081 V5011N1099 V5011N2022 V5011N2048 V5011N2055 V5011N2063 V5011N2071 V5011N2089 V5011N2097 (In.) 1/2 1/2 1/2 3/4 1 1 1/4 1 1/2 2 1/2 1/2 3/4 1 1 1/4 1 1/2 2 Flow (Cv) 1.85 2.9 4.7 7.3 11.7 18.7 29.3 46.8 1.85 4.7 7.3 11.7 18.7 29.3 46.8 Type Equal % Equal % Equal % Equal % Equal % Equal % Equal % Equal % Linear Linear Linear Linear Linear Linear Linear Media Hot/Cold Water Hot/Cold Water Hot/Cold Water Hot/Cold Water Hot/Cold Water Hot/Cold Water Hot/Cold Water Hot/Cold Water Steam Steam Steam Steam Steam Steam Steam Price 121.00 120.32 119.44 160.38 203.96 253.98 392.90 539.68 265.62 265.62 336.22 426.06 495.54 715.90 881.48 V5011G1111
Used for two-position or modulating control of steam and water and glycol solutions (to 50 % concentration) in heating or cooling systems. Direct coupled electric and pneumatic actuators for easy mounting Stroke: 3/4" Not suitable for combustible gases. Valves require a linkage and control motor; a direct-coupled actuator or pneumatic valve actuator to position the valve.
Size Part No. V5011G1111 V5011G1129 V5011F1113 (In.) 2 1/2 3 3 Flow (Cv) 63 100 100 Type Linear Linear Equal Percentage Media Steam Steam Water or Glycol Price 1041.90 1481.96 1309.74
The V5013N is a three-way threaded globe valve that controls hot water, cold water, and glycol solutions (up to 50% concentration) in heating or cooling HVAC applications. The valve is used for mixing service to direct flow from one of two inlets to a common outlet in two-position or modulating control systems. Construction: Stainless steel stem, brass seats (V5013N1048 has stainless upper seat), carbon PTFE packing, brass plug, red brass body ANSI class: 150 Suitable for pneumatic or electric/electronic actuation Stroke: 3/4"
Size Part No. (In.) 1/2 3/4 1 1 1/4 1 1/2 2 V5013N1048 V5013N1055 V5013N1063 V5013N1071 V5013N1089 V5013N1097 Flow (Cv) 4.7 7.3 11.7 18.7 29.3 46.8 Price 139.64 178.78 225.98 363.42 448.58 602.16
161.18 199.98
287.42
Single-seated valve for water or glycol. Throttling plug provides equal percentage characteristic of flow. Push down valve stem to close. Flanged pipe V5011A1882 connections Bronze removable seat, stainless steel stem, teflon discs with removable throttling plugs, straight through, cast iron body, spring loaded, self adjusting packing: teflon cone ANSI Body Class:125 psi .
Part No. V5011A1734 V5011A1767 V5011A1858 V5011A1882 Size (In.) 2 1/2 3 4 5 Flow 63 100 160 250 Stroke (In.) 3/4 3/4 1 1/2 1 1/2 Type Equal % Equal % Equal % Equal % Price 2216.06 2599.18 3598.48 5698.16
The V5013B is a mixing valve; the V5013C is a diverting valve. Used for 2-position or modulating control of water and glycol solutions (up to 50% concentration) in V5013B1003 heating or cooling systems. Valves require a linkage and control motor, a pneumatic valve actuator or a direct coupled actuator to position the valve. Stainless steel stem, bronze seat, teflon packing and plug, cast iron body ANSI class: 125
Size Part No. V5013B1003 V5013B1011 V5013C1001 V5013C1019 (In.) 2 1/2 3 2 1/2 3 Flow (Cv) 63 100 63 100 Price 2517.66 2982.80 3138.26 3520.26
1004
COMMERCIAL, VALVE
For low pressure steam or water Equal % flow Construction: FPT body bronze body and seat Stem stainless steel Plug brass Packing spring loaded teflon cone Disc composition Pressure: FPT static: 250 psi max. Flanged static: 125 psi max. Fluid temp: 281F max., 40F min. Recommended differential: 20 psi for quiet service, 35 psi max.
VB72130406
COMMERCIAL, ACTUATOR
3-WAY , MIXING, FPT
VB73130404 Connection Part No. VB73130402 VB73130404 VB73130406 VB73130408 VB73130409 VB73130410 VB73130411 Size (In.) 1/2 1/2 3/4 1 1 1/4 1 1/2 2 Flow (Cv) 2.2 4.4 7.5 14.0 20.0 28.0 41.0 Price 162.00 162.00 233.00 363.00 487.00 576.00 757.00
VALVE ACTUATOR
The VA715 and VA720 Series synchronous, motor-driven actuator provides incremental (three-wire), or proportional control of valves with up to 3/4" stroke in heating, ventilating, and air conditioning applications. This compact, non-spring return actuator responds to a variety of input signals. The VA715 and VA720 Series can be easily field mounted or ordered factory coupled to VG7000 Series bronze control valves. Input incremental: 24 Vac, 50/60 Hz Input proportional: 010 Vdc
VA71501001
VA72001001
2 way globe valve, union end, pneumatic actuator ANSI Pressure class: 250 psig Maximum steam inlet: 35 psig Medium temperature range: 20 to 281F
Connection Part No. VK7221203404 VK7221203406 Size (In.) 1/2 3/4 Flow (Cv) 4.4 7.5 Price 307.00 379.00
1005
1006
1007
1008
1009
COMMERCIAL, ACTUATOR
VALVE ACTUATOR
61 LB. MINIMUM SEATING, SPRING RETURN ADAPTER KITS
Direct-mount, spring return electric actuator provides a minimum 61 lb (271 N) force output for floating, on/off, or proportional control, and can be easily field mounted or ordered factory coupled to Johnson Controls 1/2 through 1-1/4" VG7000 Series Bronze Control Valves, with no additional linkages required. Manual hand crank allows for manual positioning of the valve, independent of a power supply Integral position indicator provides visual indication of the valve stem position
Part No. VA4233GGA2 Description Proportional Price 738.96
Y20EBE2 Part No. Y20EBE2 Y20EBE11 Description Mount Kit Adapter Kit Adapts VT Valve, VA7150 Actuator Y20 Linkage, VG7000 Valve Price 47.96 67.36
FOOT MOUNT
The M100 Series motor actuator positions dampers, valves, and related equipment in a variety of HVAC and industrial applications. It operates on 24 or 120 Vac power M120AGA1 (with cover mounted transformer), and is available with on/off, floating, or proportional control inputs. The five basic actuators can be ordered as base units without the R81 plugin electronic interface boards installed or with the input electronics factory installed. Supply voltage: 24 Vac Proportional motors require R81 control card On/off, floating models do not require R81 control card
ON/OFF FLOATING, SPRING RETURN
22 LB. CLOSE-OFF
The VA-802x Series actuators are synchronous, force-sensor-limited actuators which provide floating/ incremental or proportional control for VA80201 1/2" valves in many HVAC applications. They are motor-driven, non-spring return actuators. Used in conjunction with slotted stem valves
Part No. VA80201 VA81221 Description 24 Vac, Three-Wire Incremental 010 Vdc, Proportional Price 288.94 367.16
Linkage to mount M100 Series actuators to JCI and other manufactures' valve bodies
Y20EBA1 Seating Force Part No. Y20EBD1 Y20EBD3 Valve JCI JCI JCI Actuator M130/M120 M150 M130/M120 (psi) 75 270 100 Price 285.56 321.52 288.82
Y20EBD6
Plug in boards to adapt M100 Series actuators for alternate input types. Control card required on all M1*0XGA models
R81EAA2 Part No. R81CAA2 R81EAA2 R81GAA2 R81JAA1 R81MAA1 R81QAA3 Description Zone Bus Link, Metasys AHU, UNT Level 1 Digital Protocol Thermister Sensor Input Economizer Control, Changeover Relay, Minimum Position 0 to 24 Vdc, 0 to 24 mA Input, Adjustable Zero & Span Three-Wire 135 to 1000 Input, 6 to 10 Vdc, 0 to -2 Vdc Direct Interface Honeywell Series 90, W973, W7100 Controllers Thermistor Sensor 60 to 120F Price 616.68 1075.40 663.62 409.26 409.26 612.92
1010
COMMERCIAL, ACTUATOR
TRANSFORMER, M100 SERIES AUXILIARY M100 SERIES
Description Auxiliary Switch Kit, 1 SPDT Switch Auxiliary Switch Kit, 2 SPDT Switches
M4185A1001
Two-position, spring return motors used to operate dampers and valves. Used in applications where it is necessary or desirable to have the controlled element return to the starting position in the event of power failure or interruption
Supply Power Part No. M4185A1001 M4185B1009 M4185B1058 M8185D1006 (Vac) 120 120 120/208/240 24 Timing (Sec.) 60 60 30 30 to 60 Stroke (Degrees) 160 160 90 90 to 160
Electrically normally closed and rotated clockwise to open with a signal increase Modutrol IV Series Torque: 60 lb.-in. Foot mounted
M6184D1035
Reversing, 3-wire SPDT or floating control motors used to operate dampers and valves. Modutrol IV Series
REVERSING, 3-WIRE
Timing (Sec.) 30 to 60
Spring return, 25-lb.-in. damper actuators provide SPDT floating, two-position, three-position or modulating control of economizer systems, ventilation dampers and combustion air dampers. Use with W7459A.
M7405A1016 Part No. M6415A1016 M7415A1006 M7415B1004 M8405A1006 M8415A1004 Rotate to Open CCW CCW CW CCW CW
Stroke: 90 Timing: 90 seconds Maximum operating torque: 25 lb.-in. Power supply: 24 Vac
Application SPDT Floating Modulating Modulating 3-Position, Adjustable Minimum 2-Position, Adjustable Auxiliary Price 529.96 419.44 419.44 394.26 405.86
1011
Reversing, 3-wire floating control motors with feedback potentiometer. Used with controllers that provide SPDT output to operate dampers and valves. Modutrol IV Series Torque: 150 lb.-in.
COMMERCIAL, ACTUATOR
FOOT MOUNT
M7284A1004
PROPORTIONAL, ELECTRONIC
Proportional motors used to operate dampers and valves when used with a modulating 4-20 mA current source. Modutrol IV Series
Supply Power Part No. M7284A1004 M7284C1000 M7284Q1009 M7285A1003 (Vac) 120 120 120 120
Timing (Sec.) 30 30 30 30
Stroke (Degrees) 90 90 90 90 Includes 2-Auxiliary Switch 2-Auxiliary Switch Price 1227.62 1439.34 1540.08 1376.90
M9164A1005
Supply Power Part No. M9164A1005 M9164A1070 M9164C1001 M9164C1068 M9164D1009 M9174B1027 M9174C1025 M9174C1033 M9174D1007 (Vac) 120 24 24 120 24 120 120 120 24
Timing (Sec.) 60 60 60 30 30 to 60 30 to 60 30 60 30 to 60
Stroke (Degrees) 160 160 160 90 90 to 160 90 to 160 90 160 90 to 160 Includes 2-SPDT Auxiliary 2-SPDT Auxiliary 1-SPDT Auxiliary 2-SPDT Auxiliary 2-SPDT Auxiliary Price 953.76 886.26 1104.04 1182.90 849.28 1109.18 1222.06 1222.06 905.14
M9185 can operate valve linkages from power end or normally open valve applications M9182 can operate valve linkages from power end or auxiliary end shafts for normally closed or open valve applications
Timing (Sec.) 60 60 30 to 60
Stroke (Degrees) 160 160 90 to 160 Includes 2-Aux. Switches 1-Aux. Switch Price 1125.76 1159.56 1168.24 1308.76 1433.76
1012
COMMERCIAL, ACTUATOR
PROPORTIONAL, REVERSING, NON-SPRING RETURN PROPORTIONAL, SPRING RETURN, MODULATING DC, W7080
Reversing, proportional motors used to drive burner firing rate valves, dampers or auxiliary equipment. Replace M941A,C,D motors. Designed for flame safeguard applications in commercial/industrial oil or gas burner system. Vibration resistant electronic drive circuit. Regulated by three-wire proportional controller; 135 Stroke is field-adjustable to 90 or 160 degrees. Supply power: 24 Vac
Torque Part No. M9484D1010 M9484E1017 M9484E1033 M9484F1007 M9484F1023 M9484F1031 (Lb. 150 150 150 150 75 150 Timing (Sec.) Stroke (Degrees) Includes 1 Aux Switch (1) 1 Aux Switch (7) 2 Aux Switch (7 + 80) 2 Aux Switch 2 Aux Switch (7 + 80) Price 1146.72 1345.90 1330.56 1413.62 1428.84 1428.84
Proportional motors used to operate dampers and valves when used with a modulating DC voltage source; specifically designed for use with W7080 control panel Modutrol IV Series Supply power: 24 Vac Input signal: 14 to 17 Vdc Rotation: CW from power end on signal increase
Part No. M7685A1025 Torque (Lb.-In.) 60 Timing (Sec.) 30 to 60 Stroke (Degrees) 90 to 160 Includes Minimum Position Pot. Price 1073.24
PROPORTIONAL, MODULATING DC
These actuators provide 2-position operation of dampers, valves, and other equipment requiring the return to normal position upon power interruption. SPST controller Spring return. CCW to origin. 2-wire, SPST control Torque: 60 lb.-in. Damper area: 33 sq. ft. parallel, 43 sq. ft. opposed blade No load timing: 20 seconds
Part No. MA418 Power (Vac) 120 Price 911.00
Proportional motors used to operate dampers and valves when used with a modulating DC voltage source. Modutrol IV Series Motor and circuitry operate from 24 Vac. Input signal: 10.5 to 13.5 Vdc Torque: 60 Lb. In.
Part No. M7164A1017 M7164G1030 Volt 24 120 Timing (Sec.) 30-60 30-60 Stroke (Degrees) 90 to 160, Asymmetrical Includes Price 936.36 949.54
The MP Series actuators are used for 2-position, floating, and proportional control of dampers, valves, and program switches in heating, ventilation, air conditioning applications, or similar applications. Proportional actuators with built-in feedback potentiometers Rotation: set at 180 (adjustable 45 to 320)
MP381 Part No. MP381 MP485 MP461600 Power (Vac) 24 120 120 Torque (Lb.-In.) 220 220 50 Timing (Sec.) 130 130 90 Spring Return CW NO CW Auxiliary Switch SPDT SPDT SPDT Price 1284.00 1350.00 2131.00
1013
COMMERCIAL, ACTUATOR
ACCESSORIES
Q5001D1018
The Q5001 valve linkage connects a Modutrol motor to a 2- or 3-way valve. It is used primarily on V5011 or V5013 steam and water valves. Q5001 valve linkage is applicable to 2-way or 3-way valves in modulating or two-position service Linkage requires no adjustment when used with Honeywell valves and Modutrol IV motors Q5001 valve linkage replaces Q601 and Q618 valve linkages
Part No. Q5001D1000 Q5001D1018 Stem Force (Lb.) 80, 160 160, 320 Lift Adjustment (In.) 3/4, Fixed 3/4, Fixed Bonnet Size (In.) 1 3/8 1 3/8 Price 232.80 230.60
For use with 2-way and 3-way globe valves in modulating or two-position service. For use with 175 lb.-in. (S20) spring return or 175 and 300 lb.-in. (N20, N34) non-spring return DCAs. Accepts single or dual matching actuators for higher close-off pressures. Fail-safe operation with spring return DCAs, field selectable normally open or normally closed for direct or reverse-acting valves. Linkage threads onto valve stem. Oilite self-lubricated actuator shaft bearing. Anodized extruded aluminum housing. Precision roller-bearing rack construction to prevent premature valve packing wear and leakage. Flexible actuator mounting orientation.
Part No. Q5022A1001 Q5022B1009 Stem Force (Lbf) 1117 Max 555 Max Stroke (In.) 3/4 1 1/2 Used With V5011, V5013, VGF under 4" V5011, V5013, VGF over 4" Price 264.66 757.50
The Q5020 globe valve linkages connect a Honeywell direct coupled actuator to a steam or water globe valve. Used with two-way and three-way globe valves in modulating or two-position service. Used with 25, 50, and 142 lb-in. spring return and 35, 70, 150, and 300 lb-in. non-spring return DCA Quick and simple installation with no disassembly required Precision roller-bearing rack construction prevents premature valve packing wear and leakage Flexible actuator mounting orientation Adjustable manual override lever and valve position indicator
Part No. Q5020B1001 Q5020C1009 Stem Force (Lb.) 300 300 142 to 175 (Spring Return) Stroke (In.) Used With 3/4 V5011N, V5013N, V5011F , V5011G 1 1/2 V5051 Price 264.66 757.50
Used for remote manual control of proportioning (Series 90) motors and relays. Use with M934, M941, M944, M945, M9164, M9484, M9184, M9185
Part No. S443A1007 Resistance () 135 Price 387.88
Q181A1015
Controls one to four Modutrol (Series 90) motors from one master motor. Compatible with Modutrol III and Modutrol IV motors
Throttling Range (Degrees) Motor Controlled Cover Price 40 to 160 1 Yes 495.56 40 to 160 2 Yes 562.10
INTERFACE MODULE
For converting Series 90 Modutrol IV motors to Series 70 (electronic) control. Q7130A1006 provides selectable voltage ranges: 4 to 7, 6 to 9 or 10.5 to Q7130A1006 13.5 Vdc. Adapts M91XX Modutrol IV motor to function as M71XX model for M734H, J; M744D; M745G, P replacements. Q7230A1005 provides adjustable zero and span, voltage or current control (includes 4 to 20 mA and 2 to 10 Vdc). Adapts M91XX Modutrol IV motors to function as M72XX model for M744S, T, Y; M745S, T, Y replacements
Part No. Q7130A1006 Q7230A1005 Application Voltage Ranges (4-7 Vdc, 6-9 Vdc, 10.5 - 13.5 Vdc) Adj zero and span, 4-20 ma or 2-10 Vdc Price 198.26 198.26
Description Damper Linkage, 2-Arms, 2-Ball Joints, 1-24" Push Rod Crankarm balljoint with 1/4 - 28 UNF male threads, fits 5-16" push rods
1014
COMMERCIAL, ACTUATOR
Q605F1018
SIGNAL ADAPTER
Connects Modutrol motor to standard damper or set of dampers to provide control of duct airflow. Includes crank arm
Location (To Duct) External External, Internal Damper Amps 1 3 Ball Joints 2 4 Part No. Price 109.88 143.64 Q769A1009 Q769B1008
Q769 Adapter is used to provide a modulating signal to the M7415 Economizer Damper Motors when used with a controller. Quick-connect terminals
Spring return motors for two-position back draft, outdoor air changeover, zone, or minimum position damper control. Includes 1 SPDT auxiliary switch Stroke: 75 degrees
Supply Power Part No. (Vac) 120 240 24 24 M436A1116 M436A1124 M836A1042 M836B1033 Torque Timing (Lb.-In.) 20 20 20 15 (Sec.) 30 30 30 25 Includes 2-Wire Thermostat, SPST Thermal Breaker 2-Wire Thermostat, SPST Thermal Breaker SPST No Heat Anticipation Thermal Breaker SPST Heat Anticipation Price 480.62 484.96 474.96 474.96
Q209A1030
Internal
300
102.18
150 150
83.24 100.68
For remote setpoint control of electronic (Series 70) motors and panels.
Resistance Part No. S963B1037 S963B1086 S963B1128 S963B1136 () 480 1,000 135 270 Scale Range (F) 60 to 90 40 to 140 Open/Closed Open/Closed Use With Price T7047A, C, D, E; T7022A; 207.16 W927A-C, F; W7100 W7100 Proportional Motors Proportional Motors 149.36 128.86 131.38
2-POSITION
Used with two-wire, 24-volt room thermostat or other controller for twoposition damper control. Supply voltage: 24 Vac SPST auxiliary switch
CONTROLS & ELECTRICAL ACCESSORIES
Part No. M835A1051 Torque (Lb.-In.) 4 Timing (Sec.) 80 Open, 160 Close Price 402.72
THERMOSTAT SIMULATOR
M847A1072
For checkout of W973 logic panels and W975 satellite sequencers. Simulates the heat and cool ramp signal of a T7067 dual setpoint thermostat and the economizer low limit function
Part No. S963D1001 Description Thermostat Simulator Price 290.82 Part No. M847A1072 M847A1080
Used with two-wire 24V room thermostats or other low voltage controllers to operate the draft damper on solid fuel furnaces or boilers and other similar duty applications. Supply voltage: 24 Vac Rotates CW when energized
Torque (Oz.-In.) 30 30 Timing (Sec.) 20 20 Stroke (Degrees) 45 45 Linkage (In.) 3.8, Arm 38, Chain Price 174.34 174.34
1015
COMMERCIAL, ACTUATOR
SPECIAL PURPOSE MOUNT
ELECTRONIC ACTUATOR DRIVE NON-SPRING RETURN, 53 LB.-IN.
CP830124
The CP-8301-XXX Series electronic actuator drive is designed to process a variable 1 to 15 Vdc signal from a controller to provide proportional control of an electric gear train actuator.
Input: 1 to 15 Vdc Mounts directly onto Invensys proportional, electric, gear train actuators
Part No. CP8301120 CP830124 Power (Vac) 120 24 Price 500.00 500.00
DIRECT COUPLED
The M9100 Series is a direct-mount line of motor actuators that operates on 24 Vac or Vdc power and are available for use with floating or proportional controllers. M9116A These bi-directional actuators require no linkages and are easily installed on round damper shafts up to 3/4" diameter or square shafts up to 5/8". Integral auxiliary switches are available for indicating end-stop position or to perform switching functions at any angle within the selected rotation range. Position feedback is available through switches, a potentiometer, or a 0 (2) to 10 Vdc signal. Supply voltage: 24 Vac
NON-SPRING RETURN, 53 LB.-IN.
Part No. M9106GGA2 Control Input 0 to 10 Vdc (020 mA) Price 235.70
The M9106AGA2N02 synchronous motor-driven actuators provide floating (3-wire) control and are easily installed M9106AGSN02 on a variable air volume (VAV) box. They may also be installed on a small or medium-sized damper with a round shaft up to 1/2" in diameter or a 3/8" square shaft. The M9106AGSN02 actuator/transmitter combines an M9106-AGA2N02 with a prewired DPT-2015 differential pressure transmitter that has a 0 to 1.5 in. W.C. differential pressure range. Features: 35 dBA rating meets audible requirements for open ceilings Synchronous drive provides constant rotation time that is independent of load Direct shaft mount with single-screw coupler simplifies installation and provides 3-point shaft gripping Magnetic clutch provides torque protection for the actuator and damper Adjustable rotation stops allow application versatility with 30 to 90 clockwise or counterclockwise rotation Manual gear release
Part No. M9106AGA2N02 M9106AGSN02 M9106IGC2 Control Input Floating, 1 Minute Floating, 1 Minute, DPT Floating, On/Off, Adj. Time, 2 Aux. Price 173.18 364.30 257.32
SPRING RETURN
The M9200 Series is a direct-mount, spring return line of motor actuators that operates on 24 Vac or Vdc power and is available for use with on/off, floating, proportional, or resistive controllers. These bi-directional actuators require no linkages and are easily installed on round damper shafts up to 3/4" diameter or square shafts up to 1/2". Position feedback is available through switches (*GC* models)
SPRING RETURN, 70 LB.-IN.
Part No. M9208AGA2 M9208AGC3 M9208BGA3 Control Input 24 Vac, On/Off Floating 24 Vac, On/Off Floating, 2 Aux On/Off Price 381.44 435.76 313.52
M9108AGA2 M9108GGA2
M9220BGC3 M9220HGA3
1016
COMMERCIAL, ACTUATOR
Belimo makes a full range of electronic direct coupled actuators. They can replace many Honeywell, Johnson Controls and Invensys actuators. Proportional actuators have standard 2 to 10 Vdc, 4 to 20 mA input signals Electrical connections are 3', 18 GA plenum rated wire, 1/2" conduit (except T suffix-screw terminals)
SPRING RETURN, 22 LB.-IN. SPRING RETURN, 270 LB.-IN.
Control Type On/Off, Floating On/Off, Floating, 1 SPDT aux Proportional On/Off, Floating (Valve Actuator)
Control Type On/Off On/Off, 1 SPDT Aux Tri State, Floating Proportional Proportional
Price 287.10 338.40 349.20 393.30 444.60 Part No. NMB243 NMB24SR
GMB243 Part No. AF24 Part No. AF24 AF24SR AF120US Control Type On/Off Proportional On/Off Power Supply 24 Vac/Vdc 24 Vac/Vdc 120 Vac Price 416.70 518.40 466.20 GMB243 GMB24SR Control Type On/Off, Floating Proportional Price 408.60 544.50
1017
288.90 419.40
COMMERCIAL, ACTUATOR
DIRECT COUPLED
FIRE/SMOKE
True mechanical spring return; the most reliable fail safe. Reverse mount for clockwise or counterclockwise fail-safe. FSAF120 Check damper position easily with clear position indicator. Overload-proof throughout rotation.
Part No. FSLF120 FSLF120S1 FSNF120 FSAF120
1
CLAMP/POSITIONER INDICATOR
INDAF2 Part No. INDAF2 INDLF Description Damper Position Indicator Damper Position Indicator Use with AF Series LF Series Price 9.00 9.00
LINKAGE ACCESSORIES
KG8 Part No. KH6 KH8 KG8 Description Universal Crank Arm (For KG6 Ball Joint) Universal Crank Arm (For KG8 Ball Joint) Ball Joint (5/16", 90) Use with NFB,NFX,LF ,TF Series AFB,AFX,AF ,NFB,NFX,LF ,TF Series AF ,NFB,LF ,TF ,GM,AM,LM,AH Series Price 16.20 16.20 18.00
ZGAF Part No. ZGAF ZGNMA KHLF Description Crank Arm Adaptor Kit (includes mounting hardware) Crank Arm Adaptor Kit (includes mounting hardware) Crank Arm for Shafts to 1/2" Use with AF Series AM, NM Series LF Series Price 66.60 53.10 21.60
1018
COMMERCIAL, ACTUATOR
Actuators (DCA) are used within heating, ventilating, and air conditioning (HVAC) systems. They can drive a variety of quarter-turn, final control elements. Applications include: Volume control dampers, mounted directly to the drive shaft or remotely (with the use of accessory hardware).
NON-SPRING RETURN, 44 LB.-IN.
Part No. MN6105A1011 MN6105A1201 Control Type 2 Position, Floating 2 Position, Floating Comment 2 Aux Price 120.14 188.46 MS8103
Quarter-turn rotary valves, such as ball or butterfly valves mounted directly to the drive shaft. Linear stroke globe or cage valves mounted with linkages to provide linear actuation. 5 year warranty 24 Vac input unless noted Modulating models: 2 to 10 Vdc, 4 to 20 mA
SPRING RETURN, 27 LB.-IN.
Part No. MS8103A1030 MS8103A1130 MS4103A1030 MS4103A1130 MS7503A2030 MS7503A2130 MS7403A2030 Price 239.80 314.30 349.52 396.46
Control Type 2 Position / 24 Vac/dc 2 Position / 24 Vac/dc 2 Position / 120 Vac 2 Position / 120 Vac Modulating, Floating, 24 Vac/dc Modulating, Floating, 24 Vac/dc Modulating, Floating, 24 Vac/dc Economizer 3-Position
1019
Used to control dampers in applications such as variable air volume terminal units, and for controlling ball valves. ML6161A2009 Control signal: SPDT floating, two position All include manual declutch level Supply power: 24 Vac Non-spring return
429.80
COMMERCIAL, ACTUATOR
1020
COMMERCIAL, ACTUATOR
DIRECT COUPLED
NON-SPRING RETURN, 70 LB.-IN. SPRING RETURN, FIRE/SMOKE, 175 LB-IN.
Used to control dampers in applications such as variable air volume terminal units; suitable for use with SPDT floating ML7174A2001 thermostats, electronic systems, and for mounting on ball valves. Supply voltage: 24 Vac Timing: 90 seconds Includes manual declutch lever
Part No. ML6174B2019 ML7174A2001 Control Mode Series 60 Series 70 Control Signal SPDT Floating and 2-Position 420 mA or 210 Vdc Price 168.82 248.74
Spring return direct coupled, line voltage actuator accepts two-position (SPST) control for air dampers, air handlers, ventilation flaps, louvers and ball valves. Brush DC submotor with electronic stall protection for 2-position model Self-centering shaft coupling for various shaft sizes Metal housing features built-in mechanical end limits Field selectable spring return direction, shaft position indicator and scale, and manual winding capability with locking function Supply voltage: 24 Vac Timing: 15 seconds
Part No. MS8120F1002 MS8120F1200 Control Type 2 Position / 24 Vac 2 Position / 24 Vac Comments 15 Sec 15 Sec, 2 Aux Price 479.02 539.90
ML4115B1008
For on/off damper control with integral junction box Timing: 18 seconds
ML7421B1032 Control Signal Supply Voltage 2-Position, SPST, CCW Return 120 Vac 2-Position, SPST, CW Return 120 Vac 24 Vac 24 Vac 2-Position, SPST, CCW Return 2-Position, SPST, CW Return Price 310.42 310.42 290.64 290.64 Part No. ML6421A1017 ML6421B1040 ML7421A1032 ML7421B1023
Electric linear valve actuator works with standard Honeywell globe valves. Supply voltage: 24 Vac ML7421B/ML6421B for use with 4-6" Globe Valve only
Stroke Stem Timing (In.) Force (lbf) Control Signal (Sec.) 3/4 405 SPDT, Floating, On/Off 95 1 1/2 405 SPST. On/Off 175 3/4 405 2 to 10 Vdc 95 1 1/2 405 2 to 10 Vdc 175
Stroke Stem Timing (In.) Force (lbf) Control Signal (Sec.) 3/4 135 SPDT, Floating, On/Off 60 3/4 3/4 135 135 SPDT, Floating, On/Off 2 to 10 Vdc 30 60
Price 408.56
Direct coupled electric linear valve actuator with direct/reverse action switch. Supply voltage: 24 Vac Use up to 3" Honeywell Globe Valve
ML6425A3022 Part No. ML6425A3022 ML6425B3013 ML7425A3013 ML7425B3012 Control Signal SPDT Floating SPDT Floating 0 to 10 Vdc 0 to 10 Vdc Comments Extends Stem Down on Power Failure Retracts Stem Up on Power Failure Extends Stem Down on Power Failure Retracts Stem Up on Power Failure Price 609.22 609.22 674.64 674.62
1021
Spring return direct coupled actuators (DCA) for on/off damper control with an integral junction box. The actuator accepts an on/off signal from a singlepole, single-throw (SPST) controller. They are designed to operate reliably in smoke control systems requiring Underwriter's Laboratories Inc. UL555S ratings up to 350F. Integral spring return ensures level of return torque. 95 angle of rotation for tight damper closure. High-temperature indicator included. Supply voltage: 120 Vac Timing: 15 seconds
Electric linear valve actuator works with standard Honeywell V5011/V5013 globe valves.
ML7420A3055
For valves with 1 3/8" bonnet to 3" capacity Supply voltage: 24 Vac
1022
1023
1024
1025
COMMERCIAL, ACTUATOR
DIRECT COUPLED
PROPORTIONAL, NON-SPRING RETURN PROPORTIONAL
Mounts directly, without a linkage, on V5011A, C, F, G; V5013F and 1/2-3" water and steam threaded, V5011/V5013 N Series valve bodies. Supply voltage: 24 Vac NEMA 3R cover for outdoor Installation Field installed auxiliary switches and positive feedback pot available
Part No. ML7984A4009 ML6984A4000 Control Signal 2 to 10 Vdc, 4 to 20 mA, 135, Series 90 3 or 5 Wire Floating, Low Volts SPDT, ON/OFF Price 388.56 336.48
These actuators provide electronic proportional control of dampers, valves, or program switches requiring the return to normal position upon power MP5210500 interruption. Compatibility with 2 to 15 Vdc System 8000 input signals Proportional control by variable Vdc input signal Spring return Fixed 3 Vdc operating span Timing: 60 second extension; 40 second retraction, 15 second retraction (power loss) Requires linkage for dampers or valves Auxiliary switch (where indicated): SPDT, 10 Amps
FORTA
Programmable linear actuator for use with VB7000, VB8000 and VB9000 series 2-way, 3-way TAC valves Floating or proportional control Manual override Direct/Reverse action (switch selectable) 60 or 300 second run time (switch selectable) Equal percentage or linear (selectable) Optional auxiliary switch available M400A; 1/2 to 2" valves, M800A; 3/4 to 2" valves (VB9313 2 1/2 to 4"), M1500A; 2 1/2 to 6" valves
Part No. M400A M800A M1500A Part No. AV811 AV812 Stem Force (Lbf) 90 180 337 Description VB7000 Series Body Linkage VB8000 Series Body Linkage Price 563.00 604.00 885.00 Price 36.00 36.00
POSITIVE POSITIONING
These actuators provide electronic proportional control of dampers, valves, or program switches requiring the return to normal position upon power interruption. Proportional control by variable Vdc input signal Compatability with 2 to 15 Vdc System 8000 input signals Spring return Timing: 60 second extension; 30 second retraction, 15 second retraction (power loss) Requires linkage for dampers or valves
Part No. MP5410 MP5413 Power (Vac) 120 24 Price 688.00 688.00
HYDRAULIC
2 POSITION CONTROLS & ELECTRICAL ACCESSORIES
These actuators are used for electronic 2-position control of valves and dampers which require a return to the normal position upon power interruption. Spring return 2-wire, SPST control 2-position actuators controlled by an SPST controller No load timing: 60 seconds Requires linkage for dampers or valves Auxiliary switch (where indicated): SPDT, 10 Amp
Part No. MA5210 MA5210500 MA5213 MA5213500 Power (Vac) 120 120 24 24 Auxiliary Switch No Yes No Yes Price 434.00 542.00 434.00 542.00
The MP-500 Series actuators are for the electronic proportional control of dampers, valves, or program switches which require the return to normal position upon power interruption. This series is compatible with 0 to 10 Vdc input signals. Proportional actuators controlled by variable Vdc input signal Spring return Timing: 60 second extension; 30 second retraction, 15 second retraction (power loss) Requires linkage for dampers or valves
Power (Vac) 24
Price 706.00
1026
COMMERCIAL
ACCESSORIES
DAMPER LINKAGE VALVE LINKAGE KIT
Required to modify MA/MP 5210, 5213 actuator for damper applications with 2" stroke. For 2-position, spring return actuator Includes: mounting bracket, damper linkage with spring and AM-122 straight connector
AV600
For assembling MA, MF, MP-5X1X and MPR-5X1X Series hydraulic actuators to (1/2" to 1 1/4") valve bodies. Device consists of spring retainer, spring and combination stem extension and lock nut.
Price 118.00
F61KD3
SPDT switch Maximum liquid temperature: 250F Minimum liquid temperature: 32FKD Series -20FMD Series Maximum liquid pressure: 150 psig
Adjustment Range (GPM) Flow Increase Flow Decrease (R to Y Closes) (R to Y Opens) Min. Max. Min. Max. .6 1.1 .3 .9 .6 1.1 .3 .9 .6 1.1 .3 .9
For starting or stopping electrically operated equipment such as signal lights, alarms, motors, automatic burners, metering devices, and others
Part No. FS251 FS254 FS415SS
1" NPT Sensitivity adjusting screw makes flow adjustment easy Single pole, double throw snap switch; 3.7 FLA @ 240V Four stainless steel paddles included: 1", 2", 3", and 6" Maxium pressure: 160 psi
Price 220.80 296.00 27.20
Description Flow Switch, NEMA-1 Case Flow Switch, NEMA-4 Case Replacement Paddle Kit
1027
The F61 flow switch is designed for use on liquid lines using water, ethylene glycol solutions, or other liquids not injurious to the brass and phosphor bronze parts that F61KB-11C come in contact with the liquid. Stainless steel paddle is of three segments for use in pipes from 1" to 3" diameter. F61KB11 and F61MB1 include a 6" paddle for pipes 4" to 6". SPDT switch
Maximum liquid temperature: 250F Minimum liquid temperature: 32FF61KB11 -20FF61M* Maximum liquid pressure: 150 psig Gold-plated contacts on F61MG1C reduce intermittent contact problems in low-voltage and low-current circuits
COMMERCIAL
AIR FLOW SWITCH
PADDLE
The F62 air flow switch detects air flow or the absence of air flow in ducts, responding only to velocity of air movement.
F62AA8 P32AC2
The P32 differential pressure switch is used to sense air flow in ducts. Ambient temperature range: -40 to 167F Adjustable setpoint
SPDT switch Maximum ambient temperature: 100F Maximum air velocity: 2,000 fpm
Part No. F62AA8 F62AA9 Paddle Size (In.) 2 1/8 x 6 7/8 3 1/8 x 6 7/8 Dimension (In.) H W D 10 3/8 4 2 13/16 10 3/8 4 2 13/16 F.L. Amps (@ 240V) Price 8 203.30 8 215.64
Connection: 1/8" FPT Contact rating: 4.9 F.L. Amps @ 240V P32AC2 is supplied with 1/4" compression fitting, 4" extension tube, 2 mounting screws and O gasket
Part No. P32AC1 P32AC2 P32AF1 P32AF2C Switch Range (In. WC) SPDT SPDT SPDT SPDT .15 to 12 "WC .05 to 5"WC .05 to 5"WC .05 to 5"WC Sensitivity at Min. Setpoint (In. WC) 0.07 0.04 0.025 0.025 Includes Bracket Price
AIR VELOCITY REQUIRED TO ACTUATE SWITCH Minimum Air Velocity in FPM Required to Actuate Control1 Vertical Flow Horizontal Flow (Upward) Paddle Switch > 50 in. Duct Area 625 325 500 250
2
Width Actuation (In.) on Flow 2 1/8 Increase (R to Y Closes) Decrease (R to B Closes) 3 1/8 Increase (R to Y Closes) Decrease (R to B Closes)
1
Responds to positive, negative, or differential air pressure Eliminates fluttering or malfunction due to shock or vibration normally encountered with sail switches Contact rating: 15 resistive amps @ 277 Vac
Part No. 2374499 Range (In W.C.) 0.05 to 12.0"WC Switch SPDT Price 46.86
These are approximations only. Actual trip points are affected by air turbulence, humidity, air density, air temperature, etc.
2374495
SAIL SWITCH
Velocity range: 4802230 FPM Maximum allowable velocity: 2500 FPM Temperature range: 32300F Switch: SPDT General purpose enclosure
CONTROLS & ELECTRICAL ACCESSORIES
Part No. AF1M Description Medium, High Air Flow Switch Price 336.00
Designed to replace a wide variety of air-sensing switches found in residential and light commercial applications including furnaces, electronic air cleaners and humidifiers. Both models are provided with an SPDT switch that can be activated by positive or negative pressure, or by pressure differential. Operates diaphragm vertical Connection: 1/8", 1/4", 3/8" barbed Contact rating: 5A noninductive to 277 Vac
Part No. Setpoint Range (in W.C.) .25 to 1.0"WC 1.0 to 4.0"WC Price 35.38 35.38 2374495 2374498
FLOAT SWITCH
Liquid level control for open and closed tanks and sumps. Maximum liquid temperature: 250F Minimum liquid temperature 32F: AC Series F63AC1 -20F: BF Series Maximum ambient temperature: 180F Minimum liquid pressure: 100 psig
F.L. Amps Part No. F63AC1 F63BF1 Switch SPDT SPDT Enclosure NEMA 1 NEMA 3R (@ 240V) 8 8 Price 409.02 524.36
Low differential pressure switch for air proving or filter service applications
1910-1 Part No. 1910 0 1910 1 1910 5 Range (In. H2O) .15 to .55 .40 to 1.6 1.40 to 5.5 Price 101.78 101.78 101.78
1028
COMMERCIAL
TRANSDUCER
The digital PX Series differential pressure transducers utilize a highly accurate and stable sensor, which is microprocessor profiled for improved PXPLX01S accuracy and reliability. The stability, accuracy and ease of use characteristics of the PX models make them the ideal product for differential pressure monitoring applications.
Part No. PXPLX01S PXPLX02S PXULX05S PXUXX05S Setpoint Range 0 to 1" w.c. 1 to 10" w.c. 0 to 10" w.c. 0 to 10" w.c. Comments Field-Selectable Range Field-Selectable Range Field-Selectable Range Field-Selectable Range
The directional mode jumper provides the means to configure the transducer in unidirectional or bidirectional mode for room and building static pressure applications. Static pressure in duct or room applications Variable air volume system Filter status monitoring Input power: 12-30 VDC or 24 VAC nominal Output power: field selectable, 2-wire, loop-powered 4-20 mA (DC only), (clipped and capped), or 3-wire 0-5V/0-10V
Options Options Options Options LCD Display Yes Yes Yes No Connection Size (In.) 1/8" Barb 1/8" Barb 1/8" Barb 1/8" Barb Price 366.70 366.70 416.70 383.34
4 4 7 7
P7640 SERIES
The P7640A panel mount, P7640B duct mount and P7640U universal mount differential pressure sensors provide reliable, accurate measurement and control. Proper applications include measurement of extremely low pressure applications such as: building/room pressure, air flow, variable air volume, filter status, and duct pressure. . The P7640 pressure sensors are designed with field-selectable 4-20 mA, 0-5 Vdc, or 0-10 Vdc output. 5 year warranty. Pressure Range: (inches w.c.) A: 0-0.1, 0-0.25, 0-0.5, 0-1.0 B: 0-1.0, 0-2.5, 0-5, 0-10
Part No. P7640A1000 P7640A1018 P7640A1026 P7640A1034 P7640B1008 P7640B1016 P7640B1024 P7640B1032 P7640U1040 P7640U1052 Mounting Panel Panel Panel Panel Duct Duct Duct Duct Universal Universal Pressure Range A A B B A A B B A, B A, B Display Yes No Yes No Yes No Yes No No Yes Price 393.42 339.72 393.42 339.72 409.86 356.14 409.86 356.14 386.60 451.32
With a wide array of applications, the 2374510 kit replaces hundreds of other manufacturers air pressure switch 2374510 models. High impact polycarbonate housing Works in a variety of harsh conditions Snap-acting switch with three male 90 quick connect terminals Field adjustable set points ranging from 0.10" to 10" W.C. Switch is NEMA rated and is practically insensitive to temperature change with an operating range of -40 to +190F Installer can use 10650 sensing probe kit for hard to reach air streams 2374510 includes: Air Pressure Sensing Switch, Calibration Springs (5 options), Orifice Flow (4 options), Mounting Brackets (2 options), Hex Wrench 10650 includes: Universal Probe (7"), Mounting flange, Flange-Locking Set Screw, 3' Vinyl Tubing, Flange-Mounting Screw, Slip-On Adapter
P74FA1 Pressure Differential Range (psig) 8 to 70 2 to 26 2 to 26 8 to 60 8 to 60 2 to 26 8 to 60 Switch Differential (psi) 8 to 30 3.5, Fixed 3.5, Fixed 1.5, Fixed 1.5, Fixed 1.5, Fixed 2.5, Fixed
Switch SPST, Opens Decrease DP SPDT (Snap Acting) SPDT (Snap Acting) SPDT (Snap Acting) SPDT (Snap Acting) SPDT (Snap Acting) SPDT (Floating)
Connection (In.) Size Type 1/4 F Flare 1/4 F Flare 1/4 M Flare 1/4 M Flare 1/4 FPT 1/4 F Flare 1/4 M Flare
1029
Description Universal Air Pressure Sensing Switch Kit, SPDT Sensing Probe Kit with 7" Probe
COMMERCIAL
DIFFERENTIAL PRESSURE SWITCH, LIQUID
NEMA 4
Application Used typically to sense differential pressure across devices such as oil or water filters, pumps, heat exchangers, chillers, coils, etc. Normally provides an alarm or shutdown function in applications where there is insufficient flow in a system or when excessive pressure differential indicates a problem. It may also be used to indicate pump status.
Pressure Differential Range (psig) 1 to 10
Features SPDT switch with screw terminals Gasketed zinc-plated steel cover Strong, corrosion-resistant polyester enclosure External, multiturn adjusting screw for excellent resolution 7/8" hole for 1/2" NPT conduit connection Corrosion-resistant brass port Clearance holes for surface mounting NEMA 4 enclosure
Connection (In.) Type FPT Capillary (In.) None F.L. Amps (@ 240V) 5
Switch SPDT
Size 1/4
Price 276.94
PWT SERIES
TRANSDUCER, 3-WIRE
The PWT Series wet/wet differential pressure sensors provide reliable, accurate measurement and control of proper applications, including the PWT250 monitor and control of pump differential pressure, chiller/boiler differential pressure drop, and CW/HW system differential pressure. The PWT Series is ideal for measuring pressure across pumps, filters, heat exchangers, compressors and other non-corrosive wet media applications. The PWT Pressure Sensors incorporate microprocessor profiled sensors for exceptional accuracy and reliability. Field-selectable 4-20 mA, 0-5 Vdc, or 0-10 Vdc output. Jumper-selectable slow or fast response time. Rugged, die-cast enclosure provides NEMA 4 sealing. Jumper-selectable port swap feature. All models offer both pushbutton and digital input to zero the output. A microprocessor algorithm prevents accidental zero adjustment during normal operation. Available pressure ranges (psid) within span 0 to 50: 0 to 5, 0 to 10, 0 to 25, 0 to 50 psid 0 to 100: 0 to 10, 0 to 20, 0 to 50, 0 to 100 psid 0 to 250: 0 to 25, 0 to 50, 0 to 125, 0 to 250 psid
Part No. PWT50 PWT100 PWT250 Pressure Range (psid) 0 to 50 0 to 100 0 to 250 Comment Price 954.90 954.90 954.90
The PW Series wet/wet pressure transducers incorporate a highly accurate, stable sensor, which is microprocessor profiled for exceptional accuracy and reliability. Designed for ease of use and to provide exceptional installation savings, the PW Series is ideal for measuring pressure across pumps, filters, heat exchangers, compressors and other non-corrosive wet media applications. Application Monitor and control pump differential pressure Chiller/boiler differential pressure drop CW/HW system differential pressure Features Rugged, die-cast enclosure provides NEMA 4 sealing Field-selectable output . 0-5V/0-10VDC, or 4-20mA provides excellent systems compatibility LCD display
Part No. PWLX04S Pressure Differential Range (psig) 0 to 100 Connection (In.) Size Type 1/4 FPT Capillary (In.) None Price 983.34
PRESSURETROL
SPST PA 404 SERIES
Provides control for steam pressure. Sensitive pressure-actuated diaphragm expands or contracts with pressure variations, moving a lever mechanism PA404A1033 that operates the snap-switch. Use PA404A as high limit safety controller for steam boilers; use PA404B as fan controller for suspension-type unit heaters. Contact rating: 5.1 F.L. Amp @ 240 Vac
Operating Part No. PA404A1025 PA404A1033 PA404B1023 Switch SPST, Opens on Rise SPST, Close on Fall SPST, Opens on Fall Range (psi) 3 to 15 .5 to 9.0 .5 to 9.0 (psi) 1 to 5 1 to 5 1 to 5 Price 276.52 242.80 277.04
1030
COMMERCIAL
L404 SERIES PROPORTIONAL
Provides operating control, automatic reset limit protection Use with steam, air, noncombustible gases, or other fluids noncorrosive to pressure sensing element. Contact rating: 5.1 F.L. Amps @ 240 Vac SPDT controls include siphon loop (except L404F1102) SPST controls include ground screw
Operating Part No. L404F1409 L404F1078 L404F1375 L404F1102 L404F1383 L404F1094 L404F1391 Range (psi) 2 to 15 5 to 50 5 to 50 10 to 150 10 to 150 20 to 300 20 to 300 Differential (psi) 2 to 6 6 to 14 6 to 14 10 to 22 10 to 22 20 to 50 20 to 50 Switch SPST, close on SPDT SPST, close on SPDT SPST, close on SPDT SPST, close on rise rise rise rise Price 216.68 248.86 236.42 259.42 236.42 300.46 297.70
Modulating pressure operating control for regulation of liquid or air and other non-corrosive gases. Use with steam, air, noncombustible gases, or other fluids noncorrosive to the brass or phos-bronze (300 psi models) bellows. Do NOT use with combustible mediums or any medium chemically harmful to phosbronze bellows (10300 psi models) or brass bellows. L91A: Fixed differential L91B: Adjustable differential
Operating Range Part No. L91A1037 L91A1052 L91A1078 L91B1035 L91B1050 L91B1068 L91B1241 (psi) 0 to 15 5 to 150 110 to 300 0 to 15 5 to 150 10 to 300 10 to 300 Differential Midscale (psi) 7 Oz./Sq. In. 5 12 1 to 12 5 to 23 28 to 110 12 to 48 Price 359.94 404.20 448.16 413.66 459.64 502.44 502.44
Oil pressure sensing devices for use on oil burner systems using any type of fuel oil including heavy, pretreated oils
PROPORTIONAL
Clear plastic cover allows observation of the pressure settings and switch action Siphon loop provides thermal buffer to diaphragm
Differential (psi) 6 to 14 10 to 22 10 to 22
MANUAL RESET
P7810C1000 P7810C1026
0 to 15 0 to 300
2 to 10 15 to 50
698.44 867.52
PRESSURE TRANSMITTER
Used with Adap-Kool control systems Compact design pressure transmitter Piezoresistive sensing element Resistant against vibrations, 060G3991 pressure pulsations, humidity and ice formation Maximum test pressure: 800 psi
Part No. 060G3990 060G3991 Pressure Range (psi) 0 to 200 0 to 500 Price 416.00 416.00
1031
High pressure limit switches Stainless steel diaphragm for use with steam, air, noncombustible gases and fluids noncorrosive to stainless steel. Snap-acting switches open automatically on pressure rise; must be manually reset. Breaks 1 circuit Siphon loop included L4079W for oil applications, above 85 psi intermittent only
Line voltage pressure controller that provides automatic operating control, automatic limit protection, manual reset limit protection, and 4-20ma modulating firing rate control for pressure systems up to 300 psi. May be used with steam, air, non-combustible gases or fluids that will not corrode the pressure sensing element. LED indicators show limit function/lockout. Reset function easily accessible under cover. Clear cover allows set point and differentials to be read (but not adjusted) without opening the cover Application: On-off, Modulate and Limit Control, (breaks on pressure rise) Pipe Connections, Main or High Pressure: 1/2 in. NPT internal thread Sensor Element: Stainless Steel, solid state sensor Voltage: 120Vac, 50/60
Operating Range Part No. (psi) Differential Midscale (psi) Price
COMMERCIAL
HUMIDITY SENSOR
WALL MOUNT
Provides automatic control of a humidifier or dehumidifier for dehumidification and mildew control in air conditioning systems. Fully enclosed, dust free, SPST, snap-acting switch 24/120/240 Volt
Humidity Range (% R.H.) 20 to 80 Contact Rating (@ 240 Vac) 3.8
Finish White
Price 81.12
CONVERTIBLE
Operates humidification equipment on relative humidity fall or dehumidification equipment on relative humidity rise. Fully enclosed, dust-free, SPDT, snap-acting switch Not to be wall mounted
Humidity Range Part No. H600A1014 Switch SPDT Use With Universal (% R.H.) 20 to 80
HUMIDISTAT
CONVERTIBLE
Ranco humidity controls are designed to regulate the relative humidity of confined air spaces by cycling humidifying or dehumidifying J10809W equipment. J10 controls may be wall mounted and used to control exhaust fans or a furnace humidifier. The J10-808 control may also be duct mounted. The J10-809 Series can be wired in series or parallel with any 24 volt non-electric thermostat for humidity control in conditioned spaces.
Part No. J10808 J10809 J10809W1
1
The H8908 humidity controllers provide automatic low voltage control of humidifiers and dehumidifiers or ventilators, respectively, in central heating and air conditioning systems. They have an SPST, snap-acting, dust-proof switch and are designed for wall or surface duct mounting. Humidity range: 10 to 60% RH Temperature range: -20 to 120F Color: premier white Voltage: 24 Vac, 50VA
Part No. H8908ASPST H8908DSPST Application Humidistat Dehumidistat Price 94.78 148.74
Voltage (Vac) 24 24 24
White cover
ENTHALPY/SOLID STATE
2 POSITION HUMIDITY
Provides solid state enthalpy changeover control in economizer systems. Consists of a W7459A solid state economizer logic module and a C7400A solid state enthalpy sensor on a mounting plate Mounts in any position in outdoor air duct Controls both electromechanical and electronic systems Power supply: 24 Vac
Part No. H705A1003 Switch SPDT Price 263.92
These controllers provide low or line voltage on-off single stage control of humidifiers, dehumidifiers, valves, solenoid valves, compressors, relays, etc. Scale range: 15 to 95% RH, 5% switch differential SPDT switch
Part No. HC201 Description Duct Mount Humidity Controller Price 272.00
1032
COMMERCIAL
WALL TRANSMITTER
The HE67XX Series houses both a humidity transmitter and a temperature sensor in a single, wall-mounted unit. The humidity sensor is capable of HE67N30NOBT measuring humidity over the entire range of 0 to 100% relative humidity with an accuracy of 3%. Humidity and temperature sensors in one unit eliminate need for separate sensors and reduce installation time and cost Supply voltage: 1230 Vdc or 2030 Vac, 50/60 Hz Output: 010, 05 Vdc
Part No. HE67S30NOBT HE67N30N0BT Description Transmitter, Thin Film Nickel, Temperature Sensor Transmitter, Planar Silicon, Temperature Sensor Price 383.10 383.10
The W351P Electronic Humidity Control series has proportional outputs of 0 to 10 VDC and 0 to 20 mA. Proportional plus integral (PI) control is an option to hold setpoint regardless of load shifts on a system. The control covers a range of 10 to 90% RH and has adjustments for setpoint, integration constant, throttling range, minimum output, and mode (humidification or dehumidification). Field selectable proportional only or proportional plus integral control Surface or DIN rail mounting Ten segment LED displays percent of output signal Field selectable humidification or dehumidification mode Minimum output adjustment 5-pin connectors eliminate wiring between modules Proportional voltage: 0 to 10 VDC Proportional current: 0 to 20 mA
Part No. W351PP1 Includes Proportional Plus Integral Humidity Control Price 485.78
DUCT TRANSMITTER
The HE67XX Series combines humidity and temperature sensing in a single duct-mounted unit. The humidity sensor is capable of measuring humidity over HE67N30NOOP the entire range of 0 to 100% relative humidity with an accuracy of 3%. Supply voltage: 1230 Vdc or 2030 Vac, 50/60 Hz Output: 010, 05 Vdc
Part No. HE67N30NOOP HE67S30NOOP Description Transmitter, Thin Film Nickel, Temperature Sensor Transmitter, Planar Silicon, Temperature Sensor Price 402.24 402.24
HUMIDITY CONTROL
The W351 humidity control contains an SPDT relay with LED indication of relay status, for use with humidification and dehumidification equipment. Adjustments include setpoint (10 to 90% RH), differential (2 to 10% RH), and humidify/dehumidify mode of operation. Typical applications include humidity control of clean rooms, computer rooms, office space, and warehouses. Use with HE67S30 wall or duct humidity sensors
Part No. W351AB2 W351AA1 Includes Wall Humidity Sensor Price 277.38 882.04
ENTHALPY SENSOR
A solid state enthalpy sensor designed to sense temperature and humidity with 5% accuracy C7400A mounts in any position up to 200 ft away from Economizer Logic Module. It uses two sensors for differential control, maximizing energy savings C7400S Sylk Bus sensor is powered by and communicates on the Sylk Bus.
Part No. C7400A2001 C7400S1000 Description Enthalpy Sensor Sylk Bus Enthalpy Sensor Use With W72XX, W7459, W7460 W7220 Price 120.98 107.78
SOLID STATE
Solid state humidity sensor sense relative humidity in air Operating humidity: 1090% RH
C7600C2001 Operating Part No. C7600B2008 C7600C2001 Mounting Junction Box Wall Any position where it is exposed to freely circulating air Temperature (F) 32125 -40150 Control Signal 210 Vdc Directly Proportional 420 mA Use With T775U Price 174.74
1033
Page
1038
1038
1038
1033
Page
CONTROLS & ELECTRICAL ACCESSORIES
1042
1042
1034
Page
1029
1030
Page
912
931
1035
Page
1039
1040
912
913
1041
Page
1039
1041
1036
Page
1040 1041 1038 1033 1040 1039
Page
1041 1040 1038 1039 1038 1040 1038 1039 CONTROLS & ELECTRICAL ACCESSORIES
1041
1041
1041
1039
1037
COMMERCIAL
HUMIDITY SENSOR
HUMIDITY TRANSDUCER
Highly accurate, stable humidity transducers designed for use with HVAC controllers such as the T7350 thermostat, H775 remote humidity Wall Mount controller, and W7760 DDC control. The ceramic technology humidity sensor is not affected by condensation and other limitations that sensors that use water soluble polymer coatings exhibit and provides excellent long-term stability. Ceramic Technology allows sensors to recover fully from condensation, fog, and high humidity. (H7655A uses a polymer capacitance humidity sensor)
Part No. H7625A2010 H7625B2006 H7635A2012 H7635B2018 H7636A2022 H7655A1001 H7655B2014 Mounting Wall Duct Wall Duct Wall Wall Duct Accuracy 2% from 20 to 95% RH 2% from 20 to 95% RH 3% from 20 to 95% RH 3% from 20 to 95% RH 3% from 20 to 95% RH 5% from 30 to 70% RH 5% from 25 to 95% RH
Will accept 20K NTC temperature sensor (except H7655A) Highly accurate, repeatable, stable output with negligible hysteresis. Temperature compensated output. Zero and span trimmers, and increment/decrement recalibration feature. All units have selectable 4-20 mA, 0-10 Vdc, or 0-5 Vdc output. NIST traceable calibration; every sensor calibrated at 3 different points. All humidity sensors use the same enclosure as the T7770 sensor, except the H7655A, which uses the T7047-like enclosure.
Use With T7350, XL10, XL15 T7350, XL10, XL15 T7350, XL10, XL15 T7350, XL10, XL15 T7350, XL10, XL15, T775 Series 2000 T7350, XL10, XL15 T7350, XL10, XL15
TEMPERATURE SENSOR
PROBE
TE61001
ELEMENT
TE60001
The TE-6000 sensing elements are typically used with TE-6001 hardware assemblies in a wide variety of temperature sensing applications. All models are nickel wire-wound elements.
Resistance @ 70F (W) 1000 1000
TE-6100 completed assemblies are used in a wide variety of temperature sensing applications.
Type Nickel
Price 184.94
Electronic.
SENSOR CONTROLS & ELECTRICAL ACCESSORIES
C7046B1010 Element Insertion Part No. C7046A1004 Description No Setpoint No Setpoint Length (In.) 8 12 6 Sensor Resistance (W) 3000 @ 77F NTC 3000 @ 77F NTC Price 50.86 50.86
TE610012 Part No. TE610011 TE610012 TE6100960 TE6100961 Type Nickel Nickel Silicon Silicon Description Room Sensing Element, Phone Jack, Less Cover Room Sensing Element, Setpoint, Phone Jack, Less Cover Space Temp. Assembly, Setpoint, Wall Plate Adaptor, Less Cover Space Temperature Assembly, Wall Plate Adapter, Less Cover Price 111.20 111.52 125.74 90.64
C7046A1038
C7046B1010 Zone Discharge, Hot Deck, Cold Deck, Remote Return Air C7046D1008 Discharge Temp.
94.66
HIGH ACCURACY
Price 240.56
1038
COMMERCIAL
DISCHARGE AIR, C7100 SERIES ZIO LCD WALL MODULE
AVERAGING
Price 127.48
WALL, ELECTRONIC
C7130B1009
C7130A1001
Primary sensor for use with R7380J,L indicating controller and W7100 discharge controllers in indoor spaces. Platinum positive temperature coefficient sensor Sensor can be located up to 300' from controller
Part No. C7130A1001 C7130B1009 Operating Range (F) -40 to 100 -40 to 100 Resistance () 3484 @ 77F 1100 @ 77F Price 73.66 73.38
These sensors are 2-wire, non-polarity sensitive, Sylk bus communicating wall modules for use with Spyder programmable controllers. All models TR71 have a space-temperature sensor, network bus jack, and an LCD with three softkeys and two Up/Down adjustment keys. The TR70H model includes an onboard humidity sensor. Ability to control user access to controller parameters. Programmable for: Home screen options, tenant access, contractor access, access to controller parameters, setpoint, override, fan, and other parameters. Supplied with eight pre-programmed configurations in the wall module configuration tool. The Wall Module Configuration Wizard in the WEBs-AX Workbench makes it easy to accomplish everything from balancing a VAV box to simply viewing values like duct flow, discharge air temperature or any point in the controller Ability to balance the VAV system from the wall module. Home screen can display one to three of any of the following parameters: Temperature Setpoint, Room Temperature, Room Humidity, Outdoor Humidity, Outdoor Temperature, and Time, or one of virtually any parameter in the controller. Simple 2-wire terminal connection to the programmable controller and an optional 2-wire terminal connection for the network. All connections are polarity insensitive. Retention of user configuration, including setpoints after a power outage.
Part No. TR71 TR71H TR75 TR75H Description Zio LCD Wall Module Zio LCD Wall Module with Humidity Output Zio PLUS LCD Wall Module (w/ Scheduling Access) Zio LCD Wall Module with Humidity Output (w/ Scheduling Access) Price 178.36 350.38 257.40 418.38
A family of direct wired wall modules for use with Honeywell Excel 800, 600, 500, 100, 80, 20 (all fully programmable) and W7750, W7751, W7752, W7753, W7761 controllers. All models have a space temperature sensor; some models have setpoint adjustment, override with LED and fan switch. Non linear sensor TR21A used for averaging in T7350 application
Part No. TR21 TR21H TR21A TR21J TR22 TR22F5 TR23 TR23N TR23H TR23F3 TR23F5 TR24 Setpoint Range (F) Per selection Per selection Selectable Per knob 55 to 85F Per selection Per knob Comments Humidity, Network jack For averaging Network jack Selectable setpoint, network jack Network jack, 5 position fan Selectable setpoint, network jack, override/LED Selectable setpoint knob, network jack, override/LED Humidity, selectable setpoint knob, network jack, override/LED Selectable setpoint, network jack, override/LED, 3 position fan Selectable setpoint knob, network jack, override/LED, 5 position fan Network jack, override/LED Price 30.04 200.50 41.98 37.56 56.24 109.82 85.48 118.50 265.84 107.80 110.58 72.34
1039
COMMERCIAL
TEMPERATURE SENSOR
WIRELESS WALL SENSOR
All models report space temperature; TR23 models come with setpoint adjustment and override. Wall module to Receiver (point to TR23-WK point) wireless kits can replace any standard wired sensor Wireless Kits (wall module and receiver) are pre bound at the factory for quick installation
Part No. TR21 WS TR23 WS TR21 WK TR23 WK WRECVR
Signal Strength LED built into the wall module Low battery indication Optional dip switches available to bind any wall module to any receiver Approximate 5 year battery life with AA Alkaline (included), 7.5 year with Lithium Locking screw discourages tampering and battery theft
Description Wireless Temperature Sensor Wireless Temperature Sensor with Setpoint (F/C/Relative) and Override Button Wireless Temperature Sensor Kit: includes TR21-WS Sensor and WRECVR Receiver (Bound at Factory) Wireless Temperature Sensor Kit: includes TR23-WS Sensor and WRECVR Receiver (Bound at Factory) Receiver Used with Wireless Wall Sensors TR21-WS and TR23-WS
PROBE SENSOR
Primary electronic temperature sensor for the R7380J,L W7100 and W7505 load inputs for immersion, strap-on and duct mounting.
C7170B1000
Two-wire, platinum positive temperature coefficient sensor Sensor can be located up to 1195' from controller
Part No. C7170A1002 C7170A1010 C7170B1000 Range (F) -40 to 257 -40 to 257 -40 to 257 Resistance () 3484 @ 77F 3484 @ 77F 1097 @ 77F Lead Length (In.) 24 180 24 Price 113.48 153.20 95.92
AIR, ELECTRONIC
PROBE SENSOR
Used with the W973 single zone system, the M7415A actuator or a solid state economizer module to sense mixed or discharge air in roof-top packaged air conditioning equipment. Negative temperature coefficient causes resistance to decrease as sampled air temperature increases.
Part No. C7150B1004 Use With W973, W7459, W6210/W7210, W6215/S7215/W7460, M7415 Price 36.06
Designed for use with Adap-Kool control systems PT 1000 sensor Temperature range (F): -70 to +180
CONTROLS & ELECTRICAL ACCESSORIES
AIR, ELECTRONIC
Electronic 20K temperature sensor intended for sensing mixed or discharge air in roof top packaged air conditioning equipment. Thermistor on board with duct mount kit available for use as a probe
Part No. C7250A1001 Use With W7220 Price 31.70
DUCT
Direct-wired temperature sensor used to sense discharge or return air temperature in a duct controlled by an Excel 10 Series 2000 controller. Primary and/or secondary sensor for use with electronic control systems Integral 20K non-linear NTC thermistor
Part No. C7770A1006 Temperature Range (F) 4599 Price 41.80
1040
COMMERCIAL
DDC
Electronic temperature sensors used with DDC systems. Solid state thermistor element provides accurate sensing of temperature changes.
C7031B1009 Element Part No. C7031B2005 C7031D2003 C7031G2006 C7031G2014 C7031J2009 Application Duct Discharge Air Hot or Chilled Water, Includes well Outdoor Air Sensor Outdoor Air Sensor Duct Averaging Sensor Sensor Resistance (Ohm) 1097 at 77F 1097 at 77F 1715 at 90F 3484 at 77F 1097 at 77F Range (F) -40 to 250 40 to 350 -40 to 120 -40 to 120 40 to 180 Length (In.) 6 5 144 Price 80.68 93.40 144.48 96.40 151.02
SENSOR
C7041D is for immersion mounting sense water temperature. C7041F sense outdoor air temperature and are weatherproof for outdoor use (knockouts allow for 1/2 in. conduit
Part No. C7041B2005 C7041B2013 C7041C2003 C7041D2001 C7041K2005 C7041F2006 C7041J2007 C7041R20001 C7041P2004 C7772A1004
1
connection). 20 K NTC @ 77F sensors designed to be used with Honeywell DDC systems (Excel 500, 100, 80, 50, 10)
Element Range Application Duct Mount Duct Mount Duct Mount Use Well 50001774-001 Water/Strap On Outdoor Duct Mount, Averaging Duct Mount, Averaging Button, Surface Mount Wall Mount/Flush Type (F) -40 to 250 -40 to 250 -40 to 250 -40 to 250 -40 to 250 -40 to 250 -40 to 250 -40 to 250 -40 to 250 45 to 99
Length (In.) 6 12 18 4 Integral Integral 144 144 1 3/16 Integral Price 28.92 31.92 34.86 30.94 34.36 41.66 117.34 122.72 73.12 32.86
ROOM
DUCT
TS8101
Provides electronic sensing of room temperature at wall locations. Dial stop pins to limit setpoint range Balco resistance: 1000 @ 70F, 2.2/F
REMOTE
These temperature sensors provide electronic sensing of temperature at remote locations, ducts, plenum chambers, liquid lines, tanks, outdoor air, etc. Accuracy of 0.1% Balco resistance: 1000 @ 70F, 2.2/F System 8000 compatibility
Part No. TS8131 Description Unitary Mounting 7/32" Dia. Hole Element 3/4" x 1 1/4"L Price 71.00
Price 67.94
C7660 selectable temperature sensor is used with the W7459, W7460 and W72XX economizer controls which are mounted on an M7415/M7215 Actuator. They permit the use of outdoor air as the first stage of HVAC systems. The C7660 Selectable Temperature Sensor is only to be used with single temperature change over with the sensor located in the outdoor air. Senses temperature of outdoor air and provides a signal to economizer control with OK or not OK to economize. Selectable dip switch provides 8 change over temperature options. When temperature of outdoor air is below change over temperature, the outdoor air damper is opened to reduce the cooling load in the building.
1041
COMMERCIAL
TEMPERATURE SENSOR
ACI10KCPRO
THERMISTOR
Thermistor sensors for OEM/Industrial/DDC applications. High accuracy and interchangeability over a wide temperature range. Non polarity sensitive. CE approval (except for averaging sensors, LCDs and units with leads longer than 3 meters)
Part No. ACI10KAND4 ACI10KANR ACI10KCPD4 ACI10KCPR ACI10KCPRO ACI10KCPA12 ACI10KCPI4
Accuracy: 0.2C (from 0 to 70C) Stability: 0.13C Operating Temperature Range: -40 to 150C Operating Humidity: 0 to 90% RH non condensing Interchangeability: 0.2C Power Dissipation Constant: 3 mW/C
Price 31.50 23.40 31.50 23.40 35.98 145.90 60.70
Description Thermistor sensor, 10K (Type III), duct, 4" Thermistor sensor, 10K (Type III), wall mount room Thermistor sensor, 10K (Type II), duct, 4" Thermistor sensor, 10K (Type II), wall mount room Thermistor sensor, 10K (Type II), wall mount room-override Thermistor sensor, 10K (Type II), copper averaging, 12ft Thermistor sensor, 10K (Type II), immersion, 4"
CO2 SENSOR
CO2 sensor for Demand Control Ventilation Models available with LCD that provides sensor readings and status information. Non-Dispersion-Infrared (NDIR) C7232A1008 technology used to measure carbon dioxide gas. Gold-plated sensor provides long-term calibration stability. Device provides voltage output based on CO2 levels. Models available with SPST relay output.
Part No. C7232A1008 C7232A1016 C7232B1014 Display Yes No No Relay Output 1 SPST -NO 1 SPST -NO 1 SPST -NO Mounting Wall Wall Duct Price 538.04 522.86 627.36
WALL SENSOR
The CO2 sensors offer a fixed 02000ppm and fixed 0-10Vdc output. No adjustments are necessary. Like the C7232 sensors, these are for use in determining ventilation necessity with C7632A1004 HVAC controllers. The sensor measures the CO2 concentration in the ventilated space or duct. The sensors are used in ventilation and air conditioning systems to control the amount of fresh outdoor air supplied to maintain acceptable levels of CO2 in the space. Non-Dispersion-Infrared (NDIR) technology used to measure carbon dioxide gas. Gold-plated sensor provides long-term calibration stability. Used for CO2based ventilation control Automatic Background Calibration algorithm based on long-term evaluation reduces required typical zero-drift check maintenance.
The CWE Series is a non-dispersive infrared analyzer designed for measuring environmental CO2 concentration in ventilation systems and indoor living spaces. Its measurement range of 0-2000 ppm makes it compliant with ASHRAE and other standards for ventilation control. The CWE Series provides a user-selectable 4-20mA or 0-10VDC output. Microprocessor-based digital electronics and a unique selfcalibration algorithm improves long-term stability and accuracy. Accurate to 30 ppm 5% of measured value Repeatable to 20 ppm 1% of measured value Measurement Range: 0 to 2000 ppm 20 to 30 Vdc / 24 Vac; 100 mA maximum 5 year calibration interval
Part No. CWE Input Range Carbon Dioxide Wall Sensor Price 600.00
Display No No
1042
COMMERCIAL
ENVIRONMENTAL SYSTEMS CONTROL
DISCHARGE AIR TEMPERATURE SETBACK/SETUP MODULE
Maintains an average discharge air temperature in variable air volume (VAV) systems or other systems requiring discharge air control of multistage cooling or heating. Reduces kilowatt demand and consumption by maintaining the minimum amount of heating or cooling capacity required to hold the discharge air set point. Utilizes economizer for free cooling when available. Supply voltage: 2030 Vac
Setpoint Stages Part No. W7100A1053 W7100C1018 Heat None 2 Cool 6 4 Range (F) 40 to 90 40 to 90 Price 2517.38 2637.26
Used with W973 logic panel to conserve energy during building unoccupied periods. Provides heating setback and either cooling shutdown or cooling setup. During unoccupied periods, outdoor air damper is closed and system fan is switched from continuous to intermittent operation. In cooling setup mode, W974B automatically cycles fan with a call for heating, cooling or economizer. In cooling shutdown mode, W974B automatically cycles fan with a call for heating. Economizer provides first stage of cooling in cooling setup mode.
Temperature Selections Part No. W974B1006 Setback (F) 5, 10, 15 Setup (F) 5, 8, 12 Price 746.30
Controls discharge water temperature in reciprocating chiller and cooling tower applications. Supply voltage: 2030 Vac
Stages Part No. W7100G1001 Cool 6 Setpoint Range (F) 10 to 60 Price 2577.32
LOGIC PANEL
Controls heating, cooling and economizer operation in commercial air conditioning and heat pump equipment.
W973J1017
Description Economizer Logic with DCV and Commissioning Jade Y-Pack, includes 2 sensors, M7215 motor
Stages Part No. W973A1017 W973B1016 W973F1004 W973J1017 Heat 2 3 4 4 Cool 2 3 2 4 Comments Price 1044.24
1043
Panels can be used with staged gas, oil, or electric heat; modulating gas, hot water, or steam heat; and direct expansion or modulating chilled water cooling. Controls up to 3 on/off heat or cool stages or up to 10 on/off heat and/or cool stages using W975 satellite sequencers. Supply power: 24 Vac
The W7220 Economizer Module is the core of the JADE system and provides the basic inputs and outputs to provide simple economizer control. When used with the optional Sylk Bus sensors, the Economizer Module provides more advanced economizer functionality. W7220 can be used as a standalone economizer module wired directly to a commercial set back space thermostat and sensors to provide Outdoor Air dry-bulb economizer control. W7220 automatically detects sensors by polling the Sylk Bus to determine which sensors are present. If a sensor loses communications after it has been detected, the W7220 Economizer indicates a device fail error on its LCD. The module is designed for use with any Honeywell 2 to 10 Vdc or Honeywell Sylkbus communicating actuator. Use with sensors: dry bulb temperature and mixed air, C7250A; temperature and humidity, C7400S1000 (optional); DCV (CO2) sensor (C7232); humidity, C7600 (optional) Y7220A7215 includes the W7220A1000 logic module, (2) C7250A1001 sensors for outside and mixed air dry bulb applications, and M7215A1008 25 lb-in, foot mount, spring returnactuator motor
COMMERCIAL
ENVIRONMENTAL SYSTEMS CONTROL
ECONOMIZER LOGIC
THERMOSTAT
2 POSITION DUPLEX
Use with C7400 enthalpy sensor or C7650 dry bulb temperature sensor and Honeywell Series MS75xx actuators to proportion outdoor and return air W7212A dampers for economizer control in commercial HVAC equipment. Combines solid state enthalpy or dry bulb changeover control, minimum damper position potentiometer and compressor staging relay functions. Built-in adjustable minimum damper position potentiometer determines the amount of outdoor air admitted to meet minimum ventilation requirements.
Part No. W7210A1001 W7212A1009 Description Module Module, Demand Control Ventilation Price 397.92 340.50
Provides on/off control of heating/ cooling systems, lower line voltage, fan coils, motor starters and contactors.
TC1101 Setpoint Part No. TC1101 TC1102 TC11511
1
Range (F) 55 to 85 45 to 75 55 to 85
LOW-FLOW, PHOTOELECTRIC
ECONOMIZER MODULE
W7459 solid state economizer logic module and C7400 solid state enthalpy sensor or C7650 solid state temperature sensor are used with M7405, M7415 and W7459A1001 M8405 dedicated economizer actuators to proportion outdoor and return air dampers in economizer systems. Use C7150B mixed air sensor. W7499A1003 includes W7499A1003 economizer and M4715A1006 damper actuator
Air Use Temp. With Input M7415 C7150B or C7046 Sensor M8405 T675 or T6031 Minimum Position Potentiometer Q709A or S963B Built into M8405 Relay Output 2-SPDT 2-SPDT
Use with C7400, or C7650 and C7150B or C7046 Sensors; indoor air quality (IAQ) sensor (2-10 Vdc); and Honeywell Series 72 actuators, or M7415 Damper Actuator to proportion outdoor and return air dampers for economizer and ventilation control in commercial HVAC equipment. Voltage: 24 Vac. All models include air change and shutdown; A models also provide prepurge. Combines solid state enthalpy or dry bulb changeover control, minimum and maximum damper position potentiometer and DCV setpoint functions.
Part No. W7215A1006 W7215B1004 Use With Series 72 Actuators Series 72 Actuators Air Temperature Input C7232,C7400,C7150,C7046,C7650 C7150,C7046,C7650,C7232,C7400 Price 483.90 471.54
The InnovairFlex D4120 4-wire photoelectric duct smoke detector features a pivoting housing that fits both square and rectangular footprints and mounts to round or rectangular ductwork. A plug-in sensor head offers improved false alarm immunity and simple installation, testing, and maintenance. The InnovairFlex housing provides ample wiring space, a 3/4 inch conduit knockout, and built-in short circuit protection to prevent damage to sensitive components during installation. As many as 50 InnovairFlex detectors can be interconnected. When one unit senses smoke, all interconnected detectors will switch their relays; only the detector sensing smoke will go into alarm, thus pinpointing the fire source. Three DIP switches can be used to configure field selectable settings: cover tamper delay, number of sensors to be controlled, and shut down on trouble option. The InnovairFlex duct smoke detector can be customized to meet local codes and specifications without additional wiring. The new InnovairFlex product line is compatible with all previous Innovair models, including remote test accessories. 24 Vac/Vdc or 120 Vac operation Built-in reset button Remote test station option Remote sounder option Air velocity rating from 1004000 fpm Two DPDT form-C relay contacts Temperature range: -4 to 158F Patented sampling tube installs from front or back of the detector with no tools required Listed UL268A
Part No. D4120 D4120W Description Low-Flow, Photoelectric Low-Flow, NEMA 4, Waterproof Price 230.46 326.16
1044
COMMERCIAL
MULTI-SIGNALING ACCESSORY HORN/STROBE
Designed to work with InnovairFlex 4wire conventional duct smoke detectors. These accessories include a RTS2 key switch that can be used to select one of two connected sensors to be tested, reset, or both by a push button switch. The AOS is an optional accessory included with the RTS2-AOS model.
Part No. RTS2 RTS2 AOS AOS Description Multi Signaling Accessory Multi Signaling Accessory with Add-On-Strobe (RTS2 & AOS) Add-On-Strobe for use with RTS2 Price 147.30 220.94 73.64
Operates on either 12V or 24V Tamper resistance capability Field selectable candela settings on wall and ceiling units Automatic selection of 12 or 24 volt operation at 15 and 15/75 candela Minimal intrusion into the back box Horn rated at 88+ dbA at 16 volts Rotary switch for tone selection 3 horn volume settings Electrically compatible with existing SpectrAlert products Meets UL1971, NFPA72, and ADA signaling requirements Weight: 8.8 oz.
Part No. P2R Description Horn/Strobe Price 107.98
WEATHERPROOF ENCLOSURE
The DH400OE-1 all-weather outdoor enclosure is specifically designed to protect the system sensor hightemperature model DH400, D4120 duct smoke detector from harsh elements. This enclosure provides the protection needed to meet agency requirements in outdoor installations against rain, sleet and snow or indoors against dripping water. Special sampling tube gaskets are included as required by U.L. 268A Listing
Part No. DH400OE1 Use With DH400ACDCIHT Price 259.52
Remote test stations are automatic fire detector accessories designed to test duct smoke detectors from a convenient location. For 4-wire RTS151KEY detectors, the RTS151KEY test station features a multi-colored LED that alternates between steady green and red. For 2-wire detectors, the LED illuminates red for alarm.
Part No. RTS151 RTS151KEY Description Test Station Test Station with Key Switch Price 59.62 86.80
SAMPLING TUBES
ANNUNCIATOR
RAZ100Z
Remote annunciator for InnovairFlex duct smoke detectors. Designed for both conventional and intelligent applications. Their red LED provides visual indication of an alarm condition.
Description Remote Annunciator w/Piezo Horn Remote Annunciator Price 49.10 28.06
1045
PNEUMATIC
THERMOSTAT
T3610-1001
LOW VOLUME
The T-3610 pneumatic thermostat is a low volume proportional controller providing temperature control for a wide variety of applications including return air, mixed air, and unit ventilator control.
Part No. T3610 1001 T36101003 Includes 8' Averaging Element, 5 Holders 18" Rigid Stem Element with Duct Mounting Bracket Price 390.02 355.24
High volume output, dual temperature, dual dial thermostat. The T4506 provides individual day and night, or two setpoint temperature control. Note: Requires mounting bracket and cover to complete installation
Part No. T4506201 T4506202 T4506209 T4506203 T4506204 T4506217 Description Direct Acting, Horiz. Mounting, w/Indexing Switch, Switchover 17 psi Direct Acting, Vert. Mounting, w/Indexing Switch, Switchover 17 psi Reverse Acting, Horiz. Mounting, w/Indexing Switch, Switchover 17 psi Direct Acting, Horiz. Mounting, w/o Indexing Switch, Switchover 17 psi Direct Acting, Vert. Mounting, w/o Indexing Switch, Switchover 17 psi Reverse Acting, Horiz. Mounting, w/o Indexing Switch, Switchover 17 psi Price 339.18 339.18 339.18 302.60 302.60 302.60
T4002201
The T4002 is a high volume output, single temperature thermostat. Note: Requires mounting bracket and cover to complete installation
Low volume output, energy managing, heating-cooling thermostat. The independent setpoints can result in a deadband to encourage energy conservation by eliminating heating and cooling overlap.
Part No. T46001 T46002 Action Direct Acting Reverse Acting Price 260.88 260.88
The T-4054 heating-cooling, energy manager thermostat is a high volume output, with an adjustable deadband of T4054-1 0 to 30F between heating and cooling set points. Note: Requires mounting bracket and cover to complete installation
Part No. Action Direct Acting Reverse Acting Price 238.24 238.24
T4054 1 T4054 2
External set point adjustment Includes protective snap-on cover Includes pointer tabs to restrict the temperature adjustment range to as little as 2.5F Factory calibrated for a nominal adjustment of 7.5F, from a set point of 75F Includes attached mounting bracket
Part No. T31002 Action Direct Acting Price 455.66
The T-4756 is a high volume output, dual-temperature, dual-dial, heatingcooling thermostat. The T-4756 provides automatic changeover between direct and reverse actions when supply pressure changes from 15 to 20 psig. Note: Requires mounting bracket and cover to complete installation
Part No. T4756205 Action 15 psig Reverse/20 psig Direct Mount Horizontal Price 296.02
1046
PNEUMATIC
3 PIPE, HIGH VOLUME, DAY NIGHT
THERMOSTAT KIT
T4002301
A high volume output, dual temperature, dual dial thermostat. The T-4516 provides individual day and night control, or weekend setback. Available in direct acting with auto switchover at 17 psig Additional output air terminal which can be used as an on-off switchline pressure Includes Fahrenheit dial Provided with an optional manual indexing switch that permits you to restore the day temperature of the individual thermostat without affecting the other system thermostats. Indexing switch can be unlatched manually or will automatically reset with the day cycle.
Part No. T4516201 Action Dual Direct Acting Price 339.18
The T4002-30X thermostat with cover and two-pipe conversion kits feature a T4002201 (DA) or a T4002202 (RA) thermostat. The kits also contain a white or beige cover and cover plate, a selection of faceplates, and all other necessary parts and mounting hardware required to convert a wide array of two-pipe competitors' thermostats.
Part No. T4002301 T4002302 T4002303 T4002304 Action Direct Acting Reverse Acting Direct Acting Reverse Acting Color White White Beige Beige Price 218.20 218.20 218.20 218.20
A high volume output, heating-cooling thermostat. Provides automatic changeover between Direct Acting (DIR) and Reverse Acting (REV) when supply pressure changes from 15 to 20 psig (105 to 40 kPa). Includes fahrenheit dial Order cover and mounting bracket separately
Part No. T4752201 T4752205 Action DA/RA RA/DA Pressure (psig) 15-DA/20-RA 20-DA/15-RA Price 279.58 279.58
COVERS
The T-4000-605 (beige) universal conversion kits provide all the parts necessary to remodel existing room installations of both Johnson Controls T4000605 and non-Johnson Controls thermostats. These kits can be applied to existing instrument installations with exposed or concealed tubing. Includes terminal connector and tubing, T-400 air fittings, adjustable pipehead, tube couplings and clamps, and mounting hardware. Convert T400 models to T4000. Note: Requires T4002 thermostat and cover
Part No. Description Universal Conversion Kit Bakelite Back Adaptor Style for Dual Temperature Vertical or Horizontal Instruments with Two Pipehead Adaptors Metal Back Subplate Style for Single or Dual Temperature Vertical or Horizontal Instruments with Two Pipehead Adaptors Price 79.74 43.80 T4000605 T4000611
T40002138 Part No. T40002138 T40002139 T40002140 T40002141 T40002142 T40002144 T40002145 T40002146 T40003139 T40003141 Material Beige Plastic Beige Plastic Beige Plastic Beige Plastic Beige Plastic Beige Plastic Beige Plastic Beige Plastic White Plastic White Plastic Thermometer No No Yes No Yes No No Yes No No Mount Horiz. or Vert Horiz. Horiz. Horiz. Horiz. Vert. Vert. Vert. Horiz. Horiz. Window No No No 1 1 No 1 1 No 1 Price 23.50 23.50 30.56 23.50 30.56 23.50 23.50 30.56 24.66 24.66
T4000612
121.56
TEMPERATURE TRANSMITTER
ROOM TEMPERATURE
ACCESSORIES
The T-5002 Series room transmitters measure space or mass temperature and transmit a proportional 3 to 15 psig pneumatic output signal to an indicator, T5002201 receiver-controller, or building automation system (BAS) for automatic temperature control. Note: Requires T4002 mounting bracket and cover to complete installation
Part No. T5002201 T5002202 Action Direct Acting Direct Acting Range (F) 50 to 100 60 to 85 Price 308.72 308.72
Description T4000 Thermostat Mounting Bracket Wire Guard for Concealed Tubing Cast Aluminum Guard and Mounting Bracket
1047
PNEUMATIC
TEMPERATURE TRANSMITTER
COPPER BULB RECEIVER CONTROLLER, T5312 SERIES
T52101001
The T-5210 pneumatic temperature transmitter measures temperature and converts this measurement to an air pressure signal that is transmitted to a pneumatic receiver, controller, or receiverindicator.
Operating Range (F) 50 to 100 0 to 100 40 to 240 50 to 150 -40 to 160 0 to 100 60 to 85 20 to 120 Capillary Length (In.) 5 1/2 5 1/2 5 1/2 5 1/2 48 48 5 1/2 48 Price 330.42 330.42 330.42 330.42 346.96 346.96 330.42 346.96
T53121
The T-5312 receiver-controller directly controls dampers, valves, and other devices in a pneumatic transmission system. The T-5312 produces a proportional 3 to 15 psig pressure signal from a remotely located transmitter.
Action Proportional Two-Position Price 841.50 1006.42
Part No. T52101001 T52101002 T52101004 T52101008 T52101113 T52101114 T52101123 T52101151
COPPER
T52101009
The T-5210 pneumatic temperature transmitter measures temperature and converts this measurement to an air pressure signal that is transmitted to a pneumatic receiver, controller, or receiverindicator.
Operating Range (F) 50 to 100 40 to 240 50 to 150 50 to 150 0 to 100 40 to 65 Element Length (Ft.) 8 8 8 17 8 8 Price 373.94 373.94 373.94 381.72 373.94 373.94
The T-8000 bulb element thermostat provides proportional, two-position, direct action, or reverse action T80003 temperature control. The T-8000 is designed for applications which require the sensing element to be located where extreme conditions do not permit controller mounting or where operational adjustments to the controller would be inconvenient. This relay-type instrument is ideally suited for installations requiring the controller to be mounted on a local control panel. Proportional action, non-compensated capillary, includes two-sided dial: -10 to 124F or 110 to 244F.
Part No. T80001 T80003 Element Bulb Bulb Capillary Length (Ft.) 4 15 Price 937.36 937.36
HUMIDITY
HUMIDISTAT, DUCT
The H-3610 is a reverse acting pneumatic instrument that can be used as a humidity controller or high limit. The H3610 comes in one of two factory settings, but is field adjustable.
Part No. H36101002 Setpoint (% R.H.) 35 Usage Controller Price 675.16
The T-5800 pneumatic receivercontroller is designed for use with remote temperature, humidity, or T58001 pressure transmitters that are connected to a control variable (CV) input. The controller provides precise control of pneumatic devices. The T-5800 is capable of providing restricted supply air to low volume remote transmitters, reducing the number of air line connections needed between instruments to only one line. The "CV" input accepts the transmitted output of any pneumatic device with a calibrated output of 3 to 15 psig.
Part No. T58001 T58002 T58003 T58004 Input Single Single Dual Dual Action Proportional Proportional Plus Integral Proportional Proportional Plus Integral Price 983.80 1391.54 1359.48 1698.20
CONTROLLER
IMMERSION TEMPERATURE
The T-8020 immersion thermostat provides control of liquid temperatures. The T-8020 can function as a proportional, direct action, or reverse action instrument.
Part No. T80201 Action Proportional Price 1041.06
1048
PNEUMATIC
RESET VOLUME, VAV 3" STROKE
The P-3800 reset volume controller regulates the flow of air in variable air volume boxes. The P-3800 controls the output volume, between adjustable P38001 minimum and maximum limits, in response to a reset signal from a thermostat or some other master controller.
Part No. P38001 P38002 Thermostat (Configuration) DA, RA RA, DA (DADR), (RARR) (DARR), (RADR) Price 219.56 219.56
The D-3153 pneumatic actuator is a multipurpose positioning device used primarily for operating ventilating dampers in response to the output D31531 signals of a pneumatic controller or electro-pneumatic transducer. The D-3153 can be used with dampers up to a maximum area of 16 square feet for proportional volume control, and 25 square feet for two-position actuation, provided that the torque requirements are compatible with the specific application.
Nominal Spring Part No. D31531 D31532 D31533 D31535 D31537 Range (psig) 8 to 13 8 to 13 5 to 10 8 to 13 3 to 7 Includes Pilot Positioner, Universal Mounting Bracket Universal Mounting Bracket Universal Mounting Bracket Auxiliary Mounting Bracket Auxiliary Mounting Bracket Price 646.18 464.94 465.10 444.12 444.12
PRESSURE
P80001
The P-8000 pressure controller provides proportional or two-position control in applications that require the controller to be located on a local control panel.
Dial (2-Sided) 30" HG to 10 psig/0 to 25 psi 0 to 124 psig/110 to 244 psi Price 953.28 953.28
3" STROKE
ACTUATOR, DAMPER
2" STROKE
Range (psig) 8 to 13 8 to 13 5 to 10 8 to 13 5 to 10
Includes D9502, Universal Mounting Bracket Universal Mounting Bracket Universal Mounting Bracket Auxiliary Mounting Bracket Auxiliary Mounting Bracket
Nominal Spring Range (psig) 3 to 7 5 to 10 8 to 13 11 to 15 Description Auxiliary Mounting Kit, Swivel Mounting
1049
The D-3062 pneumatic actuator is a multipurpose positioning device used to accurately position small dampers primarily on variable air volume, D30621 terminal units and small ventilating dampers in response to output signals of a pneumatic controller or electro-pneumatic transducer. The actuator is also recommended for use on other air flow control dampers in interior locations up to a maximum area of 4 square feet for proportional volume control and 6.25 square feet for two-position actuation, provided that the torque requirements are compatible with the specific application. Requires actuator linkage kit to complete installation
The D-4073 pneumatic actuator is a multipurpose positioning device used to accurately position small dampers primarily on unit ventilator, variable air D40732 volume terminal units, and small ventilating dampers in response to output signals of a pneumatic controller or electro-pneumatic transducer. The actuator is also recommended for use on other air flow control dampers in interior locations up to a maximum area of 6.75 square feet for proportional volume control, and 11.7 square feet for twoposition actuation, provided that the torque requirements are compatible with the specific application. Where precision sequential operation is desired, or additional positioning power is necessary, use a D-9502 pilot positioner. Up to four more D-4073 actuators may be slaved from one pilot positioner for coupled dampers.
Nominal Spring
PNEUMATIC
ACTUATOR, DAMPER
4", 6" STROKE, SWIVEL MOUNT PNEUMATIC ACTUATOR
The D-3240 Series pneumatic piston actuators are multipurpose positioning devices designed for operating inlet D32461 vanes on centrifugal fans and compressors in direct response to the output signal of a pneumatic controller. These actuators can also be used on other applications that require a large amount of positioning power from a single actuator, such as large damper applications, provided that the damper is designed to withstand the high torque capabilities of the actuator.
Nominal Spring Part No. D32444 D32461 Range (psig) 8 to 13 8 to 13 Stroke (In.) 4 6 Includes Swivel Mount Bracket, Clevis, and Crank Arm Swivel Mount Bracket, Clevis, and Crank Arm Price 703.40 1089.76
The V-3802 Pneumatic Oval Top Actuator positions steam or water valve modulating plugs in response to a pneumatic signal from a controller. Comparatively small oval enclosed actuator has sufficient force to handle most seating pressures Easily field mounted to the valve bonnet with a single set screw. Refer to linkage and mounting kits in Linkage Kits for Field Coupling Johnson Controls Actuators to VT Series Valves only. Also available to replace older, installed V-3800 Series Oval Top Actuators.
Part No. V38021 Description Valve Actuator, VT, V-3800 Valves Price 189.32
ACTUATOR POSITIONER
The D-9502 pneumatic damper actuator positioners are precision relay devices used to adjust and maintain damper actuators in exact positions on D95025 those applications requiring precise or otherwise special damper positioning. Provides dynamic stabilization and/or sequential control of pneumatic damper actuators For D3246 also order spring #D9502612, and pilot spring bracket #D9502100
Part No. D95025 D95028 D950212 Usage D3244/D3246 Actuator D3153 Actuator D4073 Actuator Price 299.58 319.36 352.36
Accurately positions the modulating plugs of chilled or hot water control valves in response to a pneumatic signal from a controller. Directly replaces field installed V-3854 and V-3800 models Tailored for small terminal unit valve applications Direct replacement for oval top actuators (VT Series and older oval top series) and (V-3800 Series) actuators (except V-3801-8001 on VG7000 Series valves)
Part No. V40001 Description Valve Actuator, Small Price 217.98
VG7241ET+3008B Connection Part No. VG7241CT+3008B VG7241ET+3008B VG7241ET+3008D VG7241ET+3008E VG7241GT+3008B VG7241GT+3008D VG7241GT+3008E VG7241LT+3008B VG7241LT+3008D VG7241LT+3008E VG7241NT+3008B VG7241NT+3008E VG7241PT+3008B VG7241PT+3008D Size (In.) 1/2 1/2 1/2 1/2 1/2 1/2 1/2 3/4 3/4 3/4 1 1 1 1/4 1 1/4 Type NPT NPT NPT NPT NPT NPT NPT NPT NPT NPT NPT NPT NPT NPT Flow Cv 0.73 1.8 1.8 1.8 4.6 4.6 4.6 7.3 7.3 7.3 11.6 11.6 18.5 18.5 Spring (psi) 3 to 6 3 to 6 4 to 8 9 to 13 3 to 6 4 to 8 9 to 13 3 to 6 4 to 8 9 to 13 3 to 6 9 to 13 3 to 6 4 to 8 Price 340.16 340.16 340.16 340.16 340.48 340.48 340.48 407.04 407.04 407.04 475.36 475.36 590.82 590.82
VALVE ACTUATOR
Pneumatic valve actuators are designed to accurately position steam or water valve modulating plugs in response to a pneumatic signal from a controller. The actuators have a molded V30008011 synthetic rubber diaphragm design. Universal valve mounting design is compatible for use on all Johnson Controls valves with V-3000 mounting configurations
Description Valve Actuator, Exposed Valve Actuator, Enclosed Valve Actuator, Replaceable Diaphragm
1050
PNEUMATIC
TWO-WAY , NORMALLY OPEN, PDTC, BRONZE VALVE (Contd)
Connection Part No. VG7241RT+3008B VG7241RT+3008E VG7241RT+823C00 VG7241ST+823C00 VG7251CT+3008B VG7251ET+3008B VG7251LT+3008B VG7251NT+3008B VG7551CT+3008B VG7551ET+3008B VG7551GT+3008B VG7551LT+3008B VG7551NT+3008B Size (In.) 1 1/2 1 1/2 1 1/2 2 1/2 1/2 3/4 1 1/2 1/2 1/2 3/4 1 Type NPT NPT NPT NPT Union Globe Union Globe Union Globe Union Globe Union Angle Union Angle Union Angle Union Angle Union Angle Flow Spring Range Cv 28.9 28.9 28.9 46.2 0.73 1.8 7.3 11.6 0.73 1.8 4.6 7.3 11.6 (psi) 3 to 6 9 to 13 3 to 6 3 to 6 3 3 3 3 3 3 3 3 3 to to to to to to to to to 6 6 6 6 6 6 6 6 6 Price 753.60 753.60 1143.30 1263.92 384.98 381.36 458.84 537.72 415.34 415.34 417.30 514.66 613.18 V43321009
FLARE VALVE
These 1/2" two-way and three-way flare valves accurately regulate the flow of hot and cold water in small HVAC terminal units, including fan coils, perimeter radiation, and reheat coils.
Size Part No. V37661002 V37661003 V43321009 Type Two-Way, NO Two-Way, NO Three-Way (In.) 1/2 1/2 1/2
THREE-WAY , BRONZE
SWITCH
PRESSURE ELECTRIC, AIR
These pressure controls open or close electrical circuits from a change in operating air pressure. For pneumatic systems, pumps, or small air compressors Pressure to electric switch
P10BC7 Pressure Differential Range (psig) 3 to 20 2 to 20 3 to 20 3 to 20 Switch Differential (psi) 2, Fixed 0.2, Fixed 2 Low Stage, 2 High Stage 3 Stage1, 0.4 Stage2&3 Connection (In.) Barbed 1/8 NPSF 1/8 Barbed Fitting 1/8 Barbed Fitting F.L. Amps (@ 240V) 8 8 8 3
Stages 1 1 2 3
1051
PNEUMATIC
SWITCH
LOW PRESSURE
P67 pressure controls are used to close (or open) an electrical circuit on the basis of a predetermined air pressure signal. Typical applications include the control of air compressors, fans, pilot lights, and resistance heating elements.
Part No. P67AA1 P67CA1 P67EA5C Switch DPST, Open Fall DPST, Open Rise L-M2 Contacts Connect on Pressure Rise and Simultaneously The L-M1 Contacts Break Range (psig) 3 to 30 3 to 30 3 to 30
A40 temperature actuated pneumatic switches control when the sensed temperature reaches the control setpoint. Automatic reset A barb fitting permits "push-on" 1/4" tubing connection
A40EA1 Range Part No. A40EA1 A40EA4 A40FA1C1 A40GA2
1
Maximum Bulb Temperature (F) 400 250 400 250 Bulb 1/8" x 20' 11/16" x 6 3/4" 1/8" x 20' 11/16" x 6 3/4"
(F) 15 to 55 50 to 90 15 to 55 50 to 90
On low cutout manual reset models, the temperature must increase the amount of the differential before pneumatic switch can be closed
The V11 three-way solenoid valve is used in applications where an electrical circuit operates a pneumatic control device. 50/60 Hz
Voltage 110/120 220/240 440/480 24 Price 269.94 254.88 254.88 287.18
Switches the flow of air from one air line to another. For day night switching, heating/cooling, enthalpy switchover V6135: no exhaust function V6137: after switchover, the non active line exhausts to atmosphere Features Fast acting two-position switching mechanism Factory supplied with an integral mounting bracket for surface mounting
Part No. Voltage 2 to 4 11 to 15 15 to 19 15 to 19 Price 371.14 371.14 371.14 371.14 V61351 V61352 V61353 V61371
3-WAY
Used in applications where an electrical circuit operates a pneumatic control device. This valve diverts the air signal to the pneumatic device when the coil is energized or de-energized, depending on the choice of air connection. Air connections:NO or NC/Common Compact size with durable, solid brass construction Positive air seal Can be used in smoke control applications
Part No. V24102 Voltage 120 Price 360.80
1052
PNEUMATIC
TRANSDUCER, ELECTRO PNEUMATIC
The EP-8000 electro-pneumatic transducer converts a 0 to 10 Vdc or 4 to 20 mA signal from an electric controller into a proportional pneumatic output pressure signal. Proportional: direct acting
EP80003
Output Input Part No. EP80001 EP80002 EP80003 EP80004 Type Voltage Voltage Current Current Input Range .5 to 9 Vdc .25 to 9.5 Vdc Output Type Low Volume High Volume Range (psig) 1 to 18 5 to 19 3 to 15 3 to 15 Price 298.88 314.92 298.88 311.88
The C-2220 high-low pressure selector selects and transmits control pressure signals from a group of thermostats or C222011 controllers. The appropriate C-2220 module must be selected to work with either high or low volume thermostats or controllers. The C-2220 highlow pressure selector can be combined in master and slave module groups for applications using both high and low volume output thermostats or controllers. One master can combine with as many as 19 slaves to control 20 zones
Part No. C222011 C222012 C222013 C222014 C22205 Function Master Slave Master Slave Input Low Volume Low Volume High Volume High Volume Description Mounting Bracket 93.28 Price 130.38 99.92 130.38 99.92
TRANSDUCER
This unit has no air consumption and is immune to mounting orientation or supply line pressure fluctuations. It incorporates a manual override switch and, in the manual mode, the pressure can be increased or decreased with two pushbutton switches. Powered by 18-28 Vac/Vdc Proportional: direct acting
Input Part No. EP313020 Range 4-20 mA, 0-5 or 0-10 Vdc Output Type High Volume Output Range 0 to 20 psi Price 292.30
RELAY
SIGNAL LIMITER
The C-5230 pneumatic signal limiter imposes high and/or low limits on any pneumatic signal.
C52302 Part No. Description High or Low Limit High and Low Limit Price 206.48 248.30
C52302 C52303
SIGNAL TRANSMITTER
Price 78.66
AVERAGING CUMULATOR
The C-2040 averaging cumulator is a low volume output device designed to operate a controlled device or receivercontroller by averaging the output signals of two, three, or four controllers or transmitters. The cumulator produces an output signal equal to the average of the input signals.
Part No. C20401 Description Averaging Cumulator Price 336.60
The C-5226 pneumatic signal transmitter repeats pneumatic transmission signals or selects the higher or lower of two pneumatic signal levels directly from the output of a controller. The C-5226 may also be used as a high or low signal limiter or a differential switchover device.
1053
PNEUMATIC
RELAY
SWITCHING CUMULATOR MINIATURE PRESSURE REGULATOR
The C-9506 air switching cumulator switches output pressure from zero to full supply pressure when the pilot pressure reaches the switch point. Switch point: 212 psig Differential: 1 psig
Part No. C95061 Action 2 Position, DA Price 323.42
R40003
The R-4000 miniature pressure regulator provides a method to readjust the setpoint of pneumatic controllers in low volume applications. The output pressure varies in proportion to the rotation of the adjusting knob.
BOOSTER
The R-2080 booster relay operates as a pneumatic repeater and volume amplifier. The pilot signal is repeated at its output at a 1:1 ratio. Amplifies a pilot signal from a nonrelay, low volume controller to a large volume output signal
Part No. R20801 Description Booster Relay Price 221.44
The R130 air pressure reducing valve reduces the primary air supply pressure to a selected pressure in a compressed air system. The reducing valve can also R1301 be used as a minimum set point regulator. When used as minimum setpoint regulator, an R3710 Series .005 restrictor must be used in output line
Fitting Size Part No. (In.) 1/8 3/8 R1301 R13015 Flow Capacity (scfm) 1 20 Price 79.10 151.14
REVERSING
The R-3030 reversing relay functions as a 1:1 pneumatic inverter, volume amplifier, and inverse sequencer.
Price 322.48
ACCESSORIES
PRESSURE REDUCING STATION CONTROLS & ELECTRICAL ACCESSORIES
The remote mounted pressure reducing station regulates the output pressure in a pneumatic system to within 0.02 psi with a 20 psi variation in input pressure. Input maximum: 300 psig Output: 050 psig Flow capacity: 25 scfm Safety relief valve: 25 psi
Part No. A4000138 Description Pressure Reducing Station Price 337.08
Used to control the pressure of the air delivered to pneumatic control systems. Models available for single-pressure systems or two-pressure systems PP901A1004 (day/night or summer/winter) requiring two independently regulated pressure settings. Dual pressure units switch from the lower setting to a higher setting when main air is applied to the pilot port. Models also available including a sub-micron filter assembly and pressure gauges. Built-in adjustable safety relief valve for limiting downstream pressure Inlet pressure: 45150 psi Outlet pressure: 025 psi, factory 18 psi Safety relief pressure: 1225 psi, factory 2225 psi Secondary pressure: 05 psi above primary setting Factory set: 4.5 psi
Part No. PP901A1004 PP902C1009 PP901B1002 PP902D1007 Description Single Pressure Two Pressure Two Pressure Includes Submicron Filter, 2 Gauges Price 344.54 754.02 410.06 863.08
1054
PNEUMATIC
PRESSURE REDUCING VALVE ACCESSORY AIR PRESSURE GAUGE
The G2010 air pressure gauge provides continuous indication of air pressure in pneumatic control systems.
G20105
R130100 Part No. A4000144 A4000143 R130100 Description 1/4" NPT, 25 psi Safety Relief Valve Mounting Bracket (R13014 Only) Post Mounting Bracket (R1301 & R13014) Price 64.78 27.92 35.00
Stem Mount (In.) 1/8 NPT Center Back 1/8 NPT Center Back 1/8 NPT Center Back 1/8 NPT Center Back 1/8 NPT Center Back 1/4 NPT Center Bottom 1/8 NPT Center Back
Mounting Stem Flush or Surface Stem Flush or Surface Stem Stem Flush or Surface
A4000137
Combining coalescing and activated carbon filters in series provides clean, oil free air by removing both oil aerosols and vapors in pneumatic control systems.
Max Connection Capacity (scfm) Barb FPT FPT FPT FPT FPT FPT 1.50 23 12 17 30 50 Type In-Line Activated Carbon Activated Carbon Coalescing Coalescing Coalescing Universal Mounting Kit Price 39.92 658.08 590.82 344.60 401.16 734.56 120.12
TEST PUMP
A4000604 Part No. A4000604 A4000605 A4000633 A4000632 A4110604 Type Coalescing Coalescing Carbon Carbon Coalescing Fits A4000149 A4000601 A4000146 A4000147 A4000148 Price 86.88 169.86 407.38 345.52 77.34
Part No.
Price 1349.90
FLUKE700PTP1
This dry type filter is rated 99% efficient at a 10 micron rating. A steel housing and baked enamel finish makes the filter suitable for inside or outside locations.
Connection Part No. A4000155 A400014 1/2 3/4 (In.) MPT MPT Maximum Capacity (scfm) 5 10 Price 180.54 185.70
1055
For use with 700 series pressure modules or test gauges. Can be directly connected to the reference port consolidating two separate pieces when performing pressure calibration and testing. Can also be used with 717 pressure calibrators. Ideal for calibrating pressure transmitters, pressure switches and pressure gauges up to 600 PSI/40 bar. Two pressure ports allow simultaneous connection: 1/4" NPT female fitting for the reference gauge or pressure module 1/4" NPT female fitting for the unit under test Adjustable stroke length can be set to limit the pressure per stroke Includes: 1/4" NPT male to 1/4" BSP female 1 meter of hose (2) 1/8" NPT male quick connects 1/8" NPT female to 1/4" BSP female Seal Kit Instruction sheet
PNEUMATIC
ACCESSORIES
THERMOMETER RESTRICTOR, IN-LINE, 1/8" NPT
The T-5500 Series pneumatic temperature indicator provides continuous indication of the temperature measurement of a transmitter in a 3 to 15 psig pneumatic transmission system.
3 1/2" DIAL
Part No. R37103105 R37103107 Description Red 1/4" Barbed x 1/8" NPT, .005 In. Aqua 1/4" Barbed x 1/8" NPT, .007 In. Price 16.56 16.56
T55001051 Part No. T55001051 T55001052 T55001053 T55001054 T55001055 T55001057 T55001058 T55001059 Temperature Range (F) 50 to 100 0 to 100 50 to 150 -40 to160 40 to 240 20 to 120 40 to 65 60 to 85 Price 237.50 237.50 237.50 237.50 237.50 237.50 237.50 237.50 Part No. R37102010
Furnished with 2 3/4" lengths, 5/32" tubing, and 2 1/4" x 5/32" couplings
Price 73.46
2 1/2" DIAL
Part No. T55021001 T55021002 T55021003 T55021004 T55021005 Temperature Range (F) 50 to 100 0 to 100 50 to 150 -40 to160 40 to 240 Price 115.38 115.38 115.38 115.38 115.38 Part No. R37103005 R37103007 Description 1/4" Barbed Connection, .005 In. 1/4" Barbed Connection, .007 In. Price 13.24 13.24
The R3710 Series restrictors limit pressure and flow direction in pneumatic systems.
RESTRICTOR, IN-LINE, COMPRESSION
The R-3712 diode restrictor tee allows air flow through the bottom of the tee, in one direction only. The R-3712 is designed for inline installation using 1/4" O.D. flexible tubing.
Price 38.08
Description For Inserting 1/4" Tubing, Compression Connection .005", Red For Inserting 1/4" Tubing, Compression Connection .007", Aqua
The R-3714 diode tee provides through line low volume exhaust whenever the pressure to the diode branch is at a lower value than pressure on the through line. A higher pressure at the diode branch closes the diode and allows normal operation in the through line. Air can flow out of the bottom of the tee causing a slight reverse flow. The R-3714 is not designed for systems where the reverse flow through the restrictor can be trapped between a shut off device and an actuator.
Description 1/4" Barbed Fitting, .005 In. 1/4" Barbed Fitting, .007 In.
Price 38.08
1056
PNEUMATIC
THERMOSTAT
2 PIPE, SINGLE SETPOINT 2 PIPE, SETBACK
TP970A2145
Two pipe, single setpoint, pneumatic thermostat used to provide proportional control of pneumatic valves and damper actuators in heating and air conditioning systems.
Scale Range Throttling Range (F) 210 210 210 210 210 210 Includes Cover not Included Cover not Included Modernization Kit Convertastat Kit1 Cover not Included Convertastat Kit1 Price 150.52 163.08 250.86 163.08 150.52 163.06
Action DA DA DA DA RA RA
Pneumatic thermostat with night setback used to provide proportional control of pneumatic valves and damper actuators in heating and air TP971A2102 conditioning systems. Two pipe direct acting two temperature scale range: Day: 6090F, 13 psi Night: 5075F, 18 psi Throttling range: 210F
Part No. TP971A2003 TP971A2102 Includes Order Cover Separately Convertastat Kit Includes Adapter Plate, Wall Plate & Satin Chrome Cover Price 262.60 293.80
2 PIPE, HEATING/COOLING
Two-pipe, one- or two-temperature, pneumatic thermostat used to provide proportional control of pneumatic valves and damper actuators in heating and air conditioning systems. Throttling range: 210F DA heating @ 18 psi RA cooling @ 13 psi
Part No. TP972A2036 TP972A2002 Description 2 Pipe, 2 Temp. 2 Pipe, 1 Temp. Scale Range (F) 5575 Heating 6090 Cooling 6090 Comments Two Concealed Setpoint Knobs 78F Min. Cooling, 72F Max. Heating, Order Cover Separately Sensor only Price 249.44 232.74
1 PIPE, AIRSTREAM
Description 1 or 2 Pipe, DA1 Temp., Low Capacity 1 or 2 Pipe, RA1 Temp., Low Capacity
1057
One-pipe or two-pipe, single temperature, low capacity, pneumatic thermostat used to provide proportional control of pneumatic valves and damper actuators in heating and air conditioning systems. Requires .005 in. restrictor for one-pipe installation Scale range: 6090F Throttling range: 210F
One-pipe, single setpoint, pneumatic thermostat used to provide proportional control of pneumatic valves and damper actuators in heating and air conditioning systems. Commonly used as discharge controllers for unit ventilators. Pressure ratingsOperating: 25 psi Supply: 3 to 15 psi
PNEUMATIC
THERMOSTAT
2 PIPE, REMOTE BULB
Two-pipe, single temperature, unit mounted, remote bulb pneumatic thermostat used to provide proportional control of pneumatic valves and damper actuators in heating and air conditioning systems.
LP916A1019 Scale Range Part No. LP916A1019 LP916A1134 LP916B1082 Description 2-Pipe, DA, Single Temp., .007 in Restriction 2-Pipe, DA, Single Temp., .005 in Restriction 2-Pipe, 18 psi Heating DA, 13 psi Cooling RA, Single Temp., .005 in Restriction Comments For Unit Ventilators, 1/2" x 5 7/8" Bulb For Induction, Fan Coil Systems, 3/8" x 7" Bulb For Induction, Fan Coil Systems, 3/8" x 9" Bulb (F) 65 to 85 65 to 85 65 to 85 Fixed Throttle Range (F) 3.5 3.5 3.5 Price 340.72 318.90 408.84
TRANSMITTER
TEMPERATURE, INSERTION TEMPERATURE, AVERAGING
One-pipe, direct-acting temperature sensor used with RP908/RP920 controllers to provide proportional control of pneumatic valve or damper LP914A1052 actuators. Rod and tube insertion element for duct, well, or through-the-wall mounting. Controls are one-pipe direct acting
Temperature Sensing Range Part No. LP914A1003 LP914A1011 LP914A1052 LP914A1060 LP914A1144 (F) -40 to 160 -40 to 160 40 to 240 -40 to 160 25 to 125 Element Length (In.) 15 15 7 7 15 Mounting Duct Well Well Well Duct Price 267.58 677.56 260.80 273.06 273.06 Part No. LP915A1044 Temperature Sensing Range (F) 0200
One-pipe, direct-acting temperature sensor, used with RP908 or RP920 controllers to provide proportional control of pneumatic valve or damper actuators. Averaging, liquid-filled element for duct mounting.
Element Length (Ft.) 18 1/2 Mounting Duct Price 373.42
TEMPERATURE, AVERAGING
One-pipe or two-pipe direct-acting temperature sensor used with RP908/RP920 controllers to provide proportional control of pneumatic valve and damper actuators. 1 or 2 pipe, DA
Sensor Part No. TP974A2000 Type 1 or 2 Pipe, DA Less Cover Sensing Range (F) 50100 Price 266.18
One-pipe, direct-acting temperature sensor, used with RP908 or RP920 controllers to provide proportional control of pneumatic valve or damper actuators. Averaging, liquid-filled element for duct mounting.
Temperature Sensing Range Part No. LP915A1044 (F) 0200 Element Length (Ft.) 18 1/2 Mounting Duct Price 373.42
1058
PNEUMATIC
HUMIDITY RECEIVER CONTROLLER
One- or two-pipe, direct-acting humidity sensor used with RP908/RP920 controllers to provide proportional control of pneumatic valve or damper actuators in systems requiring humidification or dehumidification control. Pressure ratings: Operating: 25 psi Supply: 3 to 15 psi
Humidity Scale Range Part No. HP971A1008 Type 1-, 2-Pipe, DA (% RH) 15 to 75 Comments Less Cover Price 506.42
Proportional, high capacity, single or dual input pneumatic controller used in conjunction with remote sensors to provide proportional (P) or proportional RP920B1031 plus (P+I) control of temperature, humidity, pressure, or dewpoint for heating and air conditioning systems. Input signal: 315 psi Output signal: 313 psi
Part No. RP920A1025 RP920A1033 RP920B1031 RP920B1056 RP920C1021 Input Single Single Dual Dual Single Action DA DA DA RA DA Type Proportional Proportional Proportional Proportional P+I Remote Adjustment With Without Without Without With Price 401.30 401.30 500.18 495.38 687.58
HUMIDISTAT
Two-pipe, single setpoint, pneumatic humidistat used to provide proportional control of pneumatic valves on humidification or dehumidification systems. Direct Acting (DA) and Reverse Acting (RA) models are available.
Scale Range Part No. HP970A1009 HP970B1007 Type (% RH) 2-Pipe, DA 15 to 75 2-Pipe, RA 15 to 75 Throttling Range (% RH) 3 to 15 3 to 15 Flow Comments Order Cover Separately Order Cover Separately Price 466.22 466.22
ACTUATOR, DAMPER
MP909D SERIES
HP970B1007
Used for pneumatic proportional control of variable volume terminal units and small dampers. Damper load area: 3 sq. in. 2 3/8" stroke
Part No. MP909D1227 Spring Range (psi) 5 to 10 Price 65.76
MP909E SERIES
CONTROLLER
REMOTE BULB TEMPERATURE
MP909E1018
Used for pneumatic proportional control of dampers and high velocity air valves. The MP909E has an optional adjustable stroke feature. Damper load area: 6.6 sq. in.
3 to 13 5 to 10 9 to 13 3 to 13 5 to 10
Mounting Bracket, Ball Joint, Linkage Kit Mounting Bracket, Ball Joint Internal N.C. Trunnion Bracket External Trunnion Bracket
Element Style and Length Averaging, Length 3/8 x 5 1/4" Bulb 3/8 x 5 1/4" Bulb
1059
Two-pipe, single temperature, pneumatic temperature controller used to provide proportional control of pneumatic valves LP920A1039 and damper actuators in heating and air conditioning systems. Control is direct-acting, single temperature Scale range: 30150F Throttling range: 525F
Spring Range (psi) 3 to 13 Includes Mounting Bracket, Ball Joint Price 213.64
PNEUMATIC
ACTUATOR
COIL VALVE ACTUATOR
SWITCH
PNEUMATIC/ELECTRIC, P643 SERIES
MP953C1000
Pneumatic actuators provide proportional control of steam or hot or cold liquids in HVAC systems by operating V33XX, V34XX, V5011 and V5013 valve assemblies.
3/4" valve travel DA Actuator + DA Valve Body = Normally Open RA Actuator + DA Valve Body = Normally Closed
Spring Range Part No. MP953C1000 MP953C1018 MP953C1026 MP953C1067 MP953C1075 MP953D1172 MP953D1107 MP953E1319 MP953E1376 MP953F1101 Diameter 5 5 5 8 8 7 1/8 7 1/8 5 8 7 1/8 Action DA DA DA DA DA RA RA DA DA RA (psi) 2-7 8-12 4-11 2-7 8-12 3-7 8-13 4-11 4-11 8-13 Includes Standard Standard Standard Standard Standard EPDM Diaphragm Price 104.88 104.88 104.88 401.92 401.92 405.82
Used to convert a pneumatic signal from a controller to an electric switching action to provide start and stop control of equipment such as fans and pumps. Setpoint: 022 1/2 psi Differential: 313 psi Contact rating: 5.1 F.L. Amp @ 240 Vac
Part No. P643A1007 P658A1013 Switch SPDT Price 457.82
EPDM Diaphragm 401.92 Positive Positioner 480.18 5 psi span Positive Positioner 636.00 5 psi span Positive Positioner 748.04 5 psi span, EPDM Diaphragm
Pneumatic-electric switches (P658A, B) used to convert a pneumatic signal from a controller to an electrical switching action (spdt) to provide start and stop control of equipment such as fans and pumps. Setpoint range: 224 psi, adjustable differential: 2 psi, fixed Switch: SPDT
Factory Set Part No. P658A1013 P658B1012 Mounting Surface Panel (psi) 10 10 Comments Includes Case No Case Price 104.56 102.56
MP918B1030
Used for proportional control of medium to large-size dampers in HVAC systems. The MP918 is a rolling diaphragm, piston-type actuator. Damper load area: 23.8 sq. in. 3 1/2" stroke, 6" stroke (MP920)
Part No. MP918B1006 Spring Range (psi) 3 to 13 3 to 13 7 to 13 Includes External Mounting Bracket, Crank Arm Actuator Only Actuator Only Price 287.10 243.58 885.42 Part No. SP470A1000 SP470A1018 Mount Panel Panel
DIVERTING
Pneumatic diverting switch used to manually divert, block, or bleed air in pneumatic air lines to revise control sequence with a change in conditions. Commonly applied on day/night, summer-winter, on/off/auto, or start/stop functions.
Number Positions 2 3 Comments Includes Knob, Scale Plate Includes Knob, Scale Plate Price 134.18 134.18
MP918B1030 MP920B1002
BRAUKMAN ACTUATOR
MP958A1017
The MP958 pneumatic valve actuator is direct-acting and used only with Honeywell-Braukman V5852A2xx, V5862A2xx, V5853A2xx, and V5863A2xx terminal unit valves to control hot and/or chilled water.
Pressure Rating (psi) 3 to 10 8 to 11 Price 87.92 103.92
MANUAL/MINIMUM POSITION
Used to manually position a remote damper actuator or to reset the setpoint of a pneumatic controller. They SP970A1005 can also provide minimum damper position by setting a minimum pressure limit in the branchline to the damper actuator. Includes knob, scaleplate, and locknuts
Part No. SP970A1005 SP970A1013 SP970C1043 Span (psi) 10 5 5 Description 3 Port Manual/Minimum w/ Bleed 3 Port Manual/Minimum w/ Bleed 4 Port Manual/Isolated Pilot Chamber Price 84.54 83.72 111.84
1060
PNEUMATIC
RELAY
AIR SOLENOID VALVE PROPORTIONAL E/P TRANSDUCER
RP418A1057
Electrically operated pneumatic switches used to interlock an electrical system and a pneumatic control system. Usable as a diverting relay, a selector relay, or a stop and bleed relay Airflow: .42 scfm @ 20 psi with 1 psi drop
Mounting Surface Surface Surface Surface Voltage 120V 120V 208V 24V Frequency 50Hz 60Hz 60Hz 60Hz Includes Splicebox Splicebox Splicebox Splicebox Price 108.08 83.46 110.62 93.80
Electronic-pneumatic transducers are used in electronic pneumatic control systems to convert a proportional RP7517A017 electric output signal from a controller into a direct-acting, proportional pneumatic signal. Nominal range: 315 psi at 210 Vdc Only available in Long Island NY, West Chester County NY, New York City and Phoenix, AZ.
Part No. RP7517A1017 RP7517B1016 Includes 2-Wire, No Cover without Internal Power Supply 3-Wire, Cover with Internal Power Supply Price 365.48 381.14
LOAD ANALYZER
SELECTOR
Three-port relays used in HVAC systems to perform a variety of relay functions; transmit the higher of two input signals, lock out one pressure signal when a second signal is higher, or transmit the lower of two pressure signals. Operating range: 018 psi
Part No. RP470A1003 Description High/Low/Lockout Selector Price 56.96
A diaphragm logic pressure selector selects the highest and/or lowest branch pressure input from zone thermostats to operate final control elements in pneumatic control applications. Seven input manifold containing logic diaphragm, air filter, and restrictions Two analyzers can be connected together to increase inputs to twelve.
Part No. RP913A1008 Description 7 Input Relay Price 255.82
SNAP ACTING
The four port, snap acting relay converts a proportional air pressure change a controller to a positive (twoposition) pressure change. It can also divert a supply line to one of two branches. Setpoint range: 315 psi Differential: 1 psi, fixed
Part No. RP471A1002 Operation Proportional to Two Position Price 102.30 Part No. RP970A1008
CAPACITY
Direct acting, modulating relay provides increased capacity of the branchline pressure to the final control device.
Description Capacity Relay Price 90.30
SWITCHING
Pneumatic switching relays block, divert, or bleed pneumatic air lines when pilot pressure is changed from one specific value to another. Commonly applied in day/night, summer/winter, start/stop, on/off/auto and other multiple condition systems where control sequence is changed as conditions change.
Switch Part No. RP670A1001 RP670B1009 Switch SPDT DPDT Pressure (psi) 3 and 7 3 and 7 Comments Standard Standard Price 93.82 189.96
A four port non-bleed pneumatic relay which produces a modulating pressure output, proportional in a fixed ratio to pilot input changes. It is used to control pneumatic valve or damper actuators in sequence from a single thermostat.
Part No. RP971A1007 Description 3 psi Input Span for 313 psi Output Price 136.00
1061
PNEUMATIC
RELAY
REVERSING 3-WAY MIXING
A modulating relay suitable for all types of heating and air conditioning control systems to reverse and increase the capacity of the branchline pressure to the final control element. The output varies inversely to the input with an adjustable offset.
Part No. RP972A1006 Comment Standard with Mounting Clip Only Price 96.24
Three-way pneumatic mixing valve provides proportional control of hot and/or cold water in unit air conditioners and fan coil systems. M flare connection Lower port normally open Spring range: 3 to 10 psi Flow: 1.6 Cv
Part No. VP526A1076 Tube Size (SAE ODIn.) 1/2 Price 288.94
AVERAGING
THERMOSTAT
These pneumatic room thermostats are designed for proportional temperature control of pneumatic valves and damper actuators to maintain room air temperatures in heating, ventilating R2211012 and air conditioning systems. Small size, approximately 2" x 2" Factory calibrated. S.S. ball-in-seat provides pneumatic feedback for linear, stable operation. Easy-to-use throttling range adjustment and recalibration Includes tubing reducers, tubing, wall plate, mounting plate, 2 mounting screws R2211512, R2211513, R2212418, R2212419, R2212518, R2212519 are kits that include cover
1 PIPE, ROOM TEMPERATURE
Dial Dial Limit Stops No No Price 159.00 159.00 Part No. R2211012 R2211013 Description 1 Temp., 1 Pipe, DA 1 Temp., 1 Pipe, RA Range (F) 55 to 85 55 to 85
A three-port relay used in HVAC systems averages the signals from two thermostats to control a single device such as a heating coil valve for a multizone unit. The pneumatic averaging relay provides an output pressure equal to the average of two input pressures.
Part No. RP973A1005 Comment Standard with Mounting Clip Only Price 83.62
HESITATION
A three-port hesitation relay provides minimum outside air damper position plus controlled ventilation for large volume unit ventilators.
Part No. RP975A1003 Comment Standard with Mounting Clip Price 133.50
VALVE
2 PIPE, ROOM TEMPERATURE 3-PIPE SEQUENCING CONTROLS & ELECTRICAL ACCESSORIES
Dial Part No. R2212118 R2212119 R2214121 R2214122 VP522A1039 Size (In.) Part No. VP522A1039 VP522A1047 (OD SAE) 5/8 7/8 2.5 4.0 Flow (Cv) Port A Port B 1.6 2.5 Price 797.90 697.06 Description 1 Temp., 2 Pipe, DA 1 Temp., 2 Pipe, RA Day/Night, 2 Pipe, DA Day/Night, 2 Pipe, RA Range (F) 55 to 85 55 to 85 55 to 85 Day, 50 to 80 Night 55 to 85 Day, 50 to 80 Night Dial Limit Stops No No No No Price 185.00 185.00 339.00 339.00
Three-pipe, sequencing, pneumatically operated water valve for controlling both hot and cold water flow in fan-coil and induction units.
1062
PNEUMATIC
COVER TEMPERATURE
These thermostat covers are designed for use with 2" x 2" pneumatic controls only.
R21933 Dial Part No. R21928 R21933 Type Blank Full Markings None 55 to 85 Exterior Color Material Thermometer Satin Chrome Metal No Satin Chrome Metal Yes Price 47.00 47.00
Dual setpoint/deadband pneumatic room thermostats are designed for proportional control of pneumatic valves, damper actuators, and other R2212318 final control devices in environmental control systems. These devices are for use when it is desirable to set up a temperature span within which the HVAC system uses no energy for heating or cooling between selected heating and cooling setpoints. The high capacity, two pipe, pilot-operated relay type design provides pneumatic feedback for accuracy and stability over the entire operating range.
Part No. R2212318 R2212319 Action DA, Proportional RA, Proportional Price 240.00 240.00
Designed to measure air or fluid temperatures in pneumatic control systems and transmit a fixed span, 3 to 15 psig signal to controlling and R2252110 indicating devices such as receiver controllers, receiver gauges, sensitive pressure switches, or snap-acting R503-1 diverting relays. These transmitters are available with several types of sensing elements. These transmitters are "one-pipe" devices requiring an externally restricted source of constant pressure control air. Their design features pneumatic feedback to assure accuracy and stability over their temperature span.
Temperature Range Part No. R2252110 R2252151 R2252250 R2252502 R2252610 (F) -40 to 160 -25 to 125 0 to 100 40 to 140 40 to 240 Mounting Duct or Immersion Duct or Outdoor Air Duct or Immersion Duct Duct or Immersion Element Rigid, 1/4" x 7 1/16 Bulb, 1/4" x 4", 3' Cap. Rigid, 1/4" x 9 3/8" Rigid Coiled, 10" Rigid, 1/4" x 7 1/16 Price 371.00 441.00 371.00 441.00 371.00
HUMIDITY , ROOM
TRANSMITTER
ROOM TEMPERATURE
Price 318.00
These pressure selector relays are designed for use in pneumatic control systems where the application requires the comparison, selection, R2372351 and transmission of the higher or lower of two proportional signals. R2372351 can also be used as a booster relay. Proportional output
Part No. R2372351 R2372352 Action Selects Lowest of 2 Inputs Selects Highest of 2 Inputs Price 103.00 89.00
1063
The temperature transmitter measures room temperature and transmits a proportional pneumatic signal to a calibrated receiver gauge and/or receiver controller. The device is factory set to transmit a 3 to 15 psig signal over a 50 to 90F range. Permits remote readout and control of room temperature Highly sensitive bimetal sensing element Linear response to room temperature changes Field adjustable "zero" adjustment Temperature range: 50 to 90F, non adjustable
Measures room humidity and transmits a proportional pneumatic signal to a calibrated receiver gauge and/or receiver controller. The device is factory set to transmit a 3 to 15 psig signal over a 30 to 80% RH range.
Price 647.00
RELAY
PRESSURE SELECTOR
PNEUMATIC
SWITCH
PNEUMATIC/ELECTRIC ELECTRIC PNEUMATIC RELAY
Pneumatic electric switches are used in control systems requiring conversion of gradual air pressure changes to positive electrical switching actions.
R2364220
The electric pneumatic relays are three-way two-position, electrically activated air valves for use in pneumatic control systems where the application requires a variety of switching, diverting, or interlocking functions, actuated by an electrical circuit.
Part No. R2368501 R2368502 R2341521 Coil Voltage (Vac) 24 110 Price 270.00 250.00
PNEUMODULAR CONTROL
The Pneumatic Modular Control System (MCS) is designed to ease the assembly and installation of a pneumatic control system in several ways. The modularity of design and assembly speeds the prebuilding of panels and simplifies field hookup through the use of easily identified connections. The modular format allows the use of simplified engineering drawing symbols developed specifically for modular controls so that panels may be built "as drawn" directly from the submittal drawings. In addition, final system start-up and calibration checks are made easier because the panels match the drawings they were built from, thereby saving field labor time. Most compact panel-mounted pneumatic control system. Several control devices perform dual functions. No control device need be made up of separate parts. All modular control devices mount on MCS-S socket, which snaplocks to MCS-BP backplate (available in several sizes) Sockets form pneumatic piping field above control devices, and provide places for slip-in electrical connectors below them, physically separating pneumatic tubing and wiring Control devices may be removed from socket and replaced without disturbing tubing, wiring, or other control devices Pneumodular controllers, relays and switches may be mounted as stand-alone devices using available mounting brackets
REVERSING RELAY CONTROLS & ELECTRICAL ACCESSORIES
RECEIVER CONTROLLER
The receiver controllers are used with remote pneumatic transmitters to provide proportional control in pneumatic control systems. They are designed primarily for use with pneumatic transmitters; however, they maybe used with any pneumatic device having an output of 3 to 15 psig, such as thermostats or humidistats. Both direct and reverse acting models are available and each device is of the dual input type, with remote setpoint capability. These devices may be used as single input devices by using only the desired input. Nozzle and flapper relay-type receiver-controller; linear, stable and responsive. Three inputs for primary, reset and remote control point adjustment (may be used with one or two inputs). Slide-type throttling range and authority adjustments
Part No. R2341521 R2341522 R2341501 R2341502 Action Direct (DA) Reverse (RA) Direct (DA) Reverse (RA) Comment Includes Mtg. Bracket Includes Mtg. Bracket Controller Only Controller Only Price 469.00 469.00 416.00 416.00
A proportioning device designed for use in pneumatic control systems where the application requires the reversing of a proportional signal from a controlling device. The branch line pressure decreases in direct proportion to an increase in input signal pressure and also amplifies the volume of air available for the final control device, thereby minimizing system lag. The unit is factory calibrated to decrease the branch line pressure from 16 psig to 0 psig as the signal pressure increases from 0 psig to 16 psig.
Price 166.00
Snap-acting devices with adjustable setpoints designed for a variety of switching and interlocking functions in R2353502 pneumatic control systems where the application requires one or more of the following functions: feeding and exhausting branch lines, diverting a supply line to either one of two branch lines, or diverting one of two supply lines to one branch line. The primary function of these devices is to convert a proportional pneumatic signal, at a predetermined setting, into a positive pneumatic switching action. R2353503 is a nonadjustable, snap-acting, signal-comparing diverting relay designed for use in pneumatic control systems where the application requires a pneumatic switching function based on the comparison of two proportional pneumatic input signals. Positive two-position snap-action, SPDT pneumatic switching
Setpoint Part No. R2353501 R2353502 Range (psig) 3 to 20 4.5 to 20 Differential (psi) 0.2 to 0.6 2 to 4 Application Transmitter Pilot Controller Pilot Price 314.00 298.00
1064
PNEUMATIC
PRESSURE RELAY RECEIVER GAUGE
The volume booster relay is a proportioning device designed for use in pneumatic control systems where the application requires amplifying the R2372501 volume of control air to final control devices. System transmission lag is minimized by using this relay in conjunction with a proportional controller operating several diaphgragm valves or damper actuators. This device may also be used as a low pressure selector when the application requires the comparison, selection and transmission of the lower of two proportional input signals. The high pressure selector relay is a device designed for use in pneumatic control systems where the application requires the comparison, selection, and transmission of the higher of two proportional input signals.
Part No. R2372501 R2372502 Application Volume Booster/Low Pressure Selector High Pressure Selector Price 154.00 84.00
Receiver gauges for continuous indication of temperature, differential static pressure, differential pressure, pressure, enthalpy, or humidity in R2422001 conjunction with a transmitter-receiver system. Adjustable pointer: dial face overlay required (supplied in kit)
Air Connection 3/16" Barb 3/16" Barb 1/8" MPT, Center Back
CONTROLLER
RECEIVER CONTROLLER
A device designed for use in pneumatic control systems where the application requires the comparison, selection, and transmission of the highest and/or the lowest of up to six pneumatic input signals. All input ports are "dead-ended" and no signal air passes through the relay to the output ports.
Part No. R2373501 Description 6 Input Selector Relay Price 299.00
For use in conjunction with remote proportional transmitters for proportional control of pneumatic actuated dampers, valves, etc., in air conditioning systems. The transmitterreceiver-controller system may be used to control temperature, humidity, or pressure. Nozzle and flapper relay type receiver controllers Direct acting. Field changeable to reverse acting Two pipe Proportional band: 2 1/2% to 40% of primary span Note: RKS4002 input 2 has a reverse acting reset only. For direct acting the output pressure increases as input 2 increases. For reverse acting the output pressure increases as input 2 decreases
Part No. Description Replacement, Single or Dual Input Authority 10% to 200% of Primary Span Price 655.00
ACCESSORIES
PRESSURE GAUGE
RKSR4000
Pressure gauges for continuous indication of air pressure in pneumatic control systems.
R2420001 Dial Size Part No. R2420001 R2420002 R2420003 R2420004 R2420005 (In.) 1 1/2 2 2 2 2 Range (psi) 0 to 30 0 to 30 0 to 30 0 to 160 0 to 30 Mounting Stem Stem Stem Stem Flush Air Connection 1/8" MPT, Back 1/8" MPT, Bottom 1/8" MPT, Back 1/8" MPT, Back 1/4" barb, Back Price 39.00 57.00 48.00 50.00 76.00
One pipe, non-relay controllers designed primarily for use as low limit thermostats in unit ventilator and central fan system applications. Field adjustable throttling range One pipe (nozzle and flapper) operation May be used as primary or low limit controller Control range: 40 to 150F Throttling range: 10 to 50F Direct action, proportional
Part No. R2260550 Element Rigid Stem, 3/16" x 19 3/8" Price 374.00
1065
PNEUMATIC
ACTUATOR
PROPORTIONAL VALVE TO 6"
ACTUATOR ACCESSORIES
VALVE LINKAGE
Proportional pneumatic actuator with 50 sq. in. effective diaphragm area used to control 1 1/2" to 4" VB-9X13 Series and 1 1/2" to 6" VB-9323 Series valves. Requires AV430 Linkage for VB7000 Series valves Requires AV495 Linkage for VB9000 Series valves Spring range: 8 to 13 psig Nominal stroke: 1"
Part No. MK6821 Stroke (In.) 1 Price 585.00
AV401
AV400
AV400 includes parts for VB-7xxx valves and discontinued 1/2 to 1 1/4" VB-9xxx valves. AV7400 is for VB-7xxx valves only
Part No. AV400 AV7400 AV401 Usage MK2690 MK2690 MK46** Valve Size (In.) 1/2 to 1 1/4 1/2 to 1 1/4 1/2 to 1 1/4 Price 33.00 33.00 33.00
PROPORTIONAL 1 1/4"
VALVE TO
For proportional pneumatic control of 1/2" to 1 1/4" VB-111 and VB-7000, VB9000 Series valves. Requires AV400 linkage for all applications.
For assembling MS-80000 and MSR80000 Series hydraulic actuators to 1 1/2 to 2" VB-92XX and VB-9313, 1 1/2" to 3" VB-9323 valve bodies. For assembling MK-6800 Series 50 sq. in. pneumatic actuators to 1 1/2" to 2" VB-9XXX and 1 1/2" to 6" VB-9323 valve bodies.
Price 112.00
Price 132.00
RELAY
POSITIVE POSITIONING
Positive positioner pneumatic relay is used to accurately position an actuator stroke with respect to signal pressure from the controller. It can also be used to change the effective spring range of an actuator and increase the capacity of a controller. All necessary linkage provided to assemble AK-42309-500 to MK-2690-0-0-1, 3000, 4600-0-0-2, 4700, 4800, 6800, 6900, 7000, 8800 and 8900 actuators
Part No. AK42309500 Action DA Price 254.00
For assembling MS-80000 and MSR80000 Series hydraulic actuators to 2 1/2 to 4" VB-92XX and VB-931X valve bodies. For assembling MK-68X1 pneumatic actuators to 2 1/2" to 4" VB-92XX and VB-931X valve bodies.
Price 132.00
LINKAGE EXTENSION
The AV-601 valve extension kit is used to increase the allowable ambient temperature ratings of MA, MF, MP-5X1X-XXX, MPR-5X1X and MP- 541X Series actuators on applications with hot water or steam. The MF-5X1X, MP-541X, and MPR-5X1X Series of actuators require the A-601 extension.
Description MA Extension
Price 106.00
1066
PNEUMATIC
THERMOSTAT
Designed for proportional control of pneumatic valve and damper actuators used in HVAC systems. A highly sensitive bimetal element with feedback is used for accuracy and stability. The throttling range is factory set at 3F and is field adjustable.
RESET VOLUME, UNIVERSAL
CTC1631
Setpoint range: 55 to 85F Throttling range: 3 to 12F HFO0010restrictor tee (14.4 scim) required for CTC16* series. Requires cover and/or scaleplate for complete installation
1 PIPE, ROOM TEMPERATURE
Part No. CTC1611 CTC1612 Type 1 Pipe 1 Pipe Action DA RA Price 64.76 64.76
Designed for use on variable air volume terminal units in HVAC systems. It is a submaster air velocity controller whose velocity setpoint is reset between an adjustable minimum and maximum limit by a master controller, typically a room thermostat. Used for either direct or reverse acting reset for normally open or normally closed VAV terminal units. It has a factory set reset start point and reset span which can be field adjusted. The reset span is always constant no matter what minimum and maximum limits have been set. For cooling or heating, DA or RA applications
Part No. CSC301110 CSC302110 CSC302510 Description 0 to 1" Range; 8 Psig Start 0 to 1" Range; 3 Psig Start 0 to 2" Range; 8 Psig Start (High Flow, for Trane Units) Price 228.88 228.88 228.86
RELAY
PNEUMATIC-ELECTRIC
COVER
Designed for use in control circuits of HVAC systems Ideal for applications such as starting fan coil unit fans, exhaust fans, and direct control of electric duct heaters With case and cover
Switch SPDT DPDT Price 118.04 182.92
REVERSING
CONTROLLER
RESET VOLUME, VAV
RCC1501 RCC1101
AVERAGING
Price 171.68
Designed for applications that do not require large amounts of output air volume. Suitable for room or zone applications such as VAV terminals. Use where desired output signal to the controlled device is to be the average of two source signals. With bracket
Part No. RCC1102 Description Averaging Relay Price 32.82
Designed for use on VAV terminal units in HVAC systems Submaster air velocity controllers whose velocity setpoint is reset between adjustable minimum and maximum limits by a master controller, typically a room thermostat For DA cooling or RA heating applications, no dampers Set point range: Minimum0 to 1" wg Maximummin. + 1" wg
Designed for reversing a proportional signal from a controlling device. Factory adjusted to decrease branch line pressure as the input pressure increases. With bracket.
1067
PNEUMATIC
RELAY
DIVERTING
Adjustable diverting relays are SPDT devices that divert one signal to either of two branch circuits or select one of two inputs and transmit it to another control device. They also can be used to feed or exhaust a circuit.
Part No. RCC1109 Description Diverting Relay Price 63.90
MCP10402211
Designed for use in pneumatic control systems positioning automatic air dampers and can be used for gradual or two position applications. With 1/2" crank arm, bracket mount Effective area 1030: 7 sq. in.; 1040:11 sq. in.
THERMOSTAT
2 PIPE, HIGH VOLUME
Provides proportional single output, single setpoint, 2-pipe pneumatic room temperature control. Requires cover to complete installation
Action Direct Acting Reverse Acting Price 138.20 138.20
ACTUATOR
HYDRAULIC, 1 11/16" STROKE
Designed to control small dampers such as air terminal units. Furnished with a right-angle mounting MCP80312101 bracket for mounting to the side of a VAV terminal. The bronze bushing actuator may be rotated in the bracket so the air connection can be placed where desired. The end of the shaft has a slot and clevis pin to allow direct connection to the damper linkage of a VAV terminal. The metal body allows them to be used in ceiling plenums where concern for local safety codes is a factor. Bronze bushing Effective area: 8 sq. in. with clevis and cotter pins
Part No. MCP80312101 MCP80313101 MCP80313102 MCP80315101 Spring Range (psi) 3 to 12 5 to 10 5 to 10 8 to 13 Description Bronze Bushing with Clevis and Cotter Pins Bronze Bushing with Clevis and Cotter Pins Delrin Bushing without Clevis and Cotter Pins Bronze Bushing with Clevis and Cotter Pins Price 103.60 95.98 103.60 103.60
192841
Pneumatic room thermostat kit converts most existing pneumatic room thermostats to a Powerstar 192, 2-pipe, single setpoint unit. Includes cover and back plate
Action Direct Acting Reverse Acting Price 156.44 156.44
COVER KIT
Retrostat plastic thermostat cover kit with dial plates that expose or conceal the setpoint indicator and/or thermometer. Thumb wheel covers to conceal setpoint adjustment. Snap-out tab for day/night lever. Desert beige (standard) For use with 192 series pneumatic thermostats
Part No. 192868 Description Powers Thermostat Cover Kit Price 43.48
1068
PNEUMATIC
CONTROLLER
RECEIVER CONTROLLER 1/4" OD
1950011
The 195 series controller receives a pneumatic input of 3 to 15 psi from a transmitter and then provides a pneumatic output based on the net pneumatic input and the mechanical settings of the setpoint and proportional band. The controller can be easily changed from direct to reverse acting.
Transmitter Inputs One Up to three Price 361.82 519.22
Nominal I.D.: 170" Nominal wall thickness: .040" Coil length: 250'
Part No. PT14BLK PT14TT1 PT14BLU PT14GRN PT14ORG PT14RED PT14VIO PT14WHT PT14YEL
1
Burst pressure: > 500 psi @ 75F PT14TT are twin connected tubes
Color Black Black Black Black Black Black Black Black Black
ID Stripe None None Blue Green Orange Red Violet White Yellow
Price 52.08 150.22 63.10 63.10 63.10 63.10 63.10 63.10 63.10
ACTUATOR DAMPER
4" STROKE
3/8" OD
3312904
Designed with a 4-inch stroke, the No. 4 pneumatic actuator is a rugged, metal-fabricated devce that provides gradual or positive actuation of HVAC and fire/smoke dampers.
Nominal I.D.: .250" Nominal wall thickness: .062" Coil length: 250'
Part No. PT38BLK PT38BLU PT38GRN PT38ORG PT38RED PT38VIO PT38WHT PT38YEL Color Black Black Black Black Black Black Black Black
1/2" OD
Nominal I.D.: .375" Nominal wall thickness: .062" Coil length: 250'
Part No. PT12BLK Color Black
TUBING
PLEXCO flame retardant polyethylene tubing is produced for pneumatic control applications where high quality plastic tubing with flame retardant and superior stress-crack resistance properties are PLT532BLK required for long term, reliable performance. Its light weight and flexibility provide for ease of handling and installation. Tubing systems are marked with a white ink numbering system over the full length of the tubing. "Flame Retardant" indicates that the tubing materials have the ability to retard and extinguish the flame once its source is removed. Standard test results on actual extruded tubing meet or exceed the requirements of ASTM D-635.
5/32" OD
ID Stripe None
Price 178.40
Nominal I.D.: .096" Nominal wall thickness: .030" Coil length: 500'
Part No. PT532BLK PT532TT1
1
Burst pressure: > 500 psi @ 75F P532TT are twin connected tubes
1069
PNEUMATIC
ACCESSORIES
Eliminate water from your compressed air lines Improve the efficiency of your compressed air system Reduce operating costs Designed to cool your air supply to the specified dew point with minimum pressure drop Two stage separator efficiently removes condensed moisture Automatic condensate drain Cooling temperatures are automatically and accurately controlled over a wide range of load and ambient conditions Voltage: 115/1/60
Capacity Part No. HPR5 10 HPR25 HPR35 (SCFM) 5 to 10 25 35 Connection Type OD MPT MPT Size (In.) 3/8 3/4 3/4 Dim. (In.) H xW x D 15 22 22 13 13 15 15 15 15 Ship Wt. (Lbs.) 64 88 92 Price 1418.00 2294.00 2938.00
Identifies front and back side faults Built-in short cycle protection, knob adjustable delay on break, 0.1 to 5 minutes Monitors: voltage unbalance, high/low voltage, phase loss, reversal, incorrect sequencing, rapid short cycling Input: Voltage: 190630 Vac, 50/60 Hz Voltage unbalance: Adjustable 225% Control: 18240 Vac Output: Relay, SPDTNormally open: 10 amps Normally closed: 6 amps
Part No. ICM400C Description 3-Phase Voltage Monitor Price 227.86
For draining and expelling Condensed moisture Emulsified oil Viscous condensate
Part No. #67 Connection, FPT (In.) 3/8 Price 240.00
DP3800
Electrically operated automatic condensate drain for pneumatic control systems and all other compressed air services. Voltage: 110V/60Hz
Connection, FPT (In.) 1/2 3/8 MWP (psc) 150 300 Price 388.00 366.00
Monitors front and back side of system Programmable: 25-fault memory storage Independent high/low voltage settings for dual voltage compressor applications High temperature LCD to 167F Simultaneous voltage display: No scrolling Line voltage programmable Reset: Auto or manual Monitors: Voltage unbalance, high/low voltage, phase loss, reversal, incorrect sequencing, rapid short cycling Does not require control voltage for operation Input: Voltage: 190630 Vac Voltage unbalance: Adjustable 225% Control: 18240 Vac Output: Relay, SPDTNormally open: 10 amps Normally closed: 6 amps
Part No. ICM450C Description 3-Phase Voltage Monitor w/Display Price 245.00
1070
POWER MONITORING
Switches upon activation of current in sensed line
Low cost, single side 3-phase protection Monitors for phase reversal, phase loss, phase unbalance % as a function of input voltage Less than 1 second phase loss response Automatic reset from a fault condition Input: Line voltage: 190600 Vac Control voltage: 115230 Vac 50/60 Hz Output: Relay, SPST normally open: 30 amps
Part No. ICM402 Description 3-Phase Monitor Price 58.00
R310AD1 Part No. R310AD1 R310AE2 Output Voltage 24 120/240 Input Range 0.5 to 200 Amps 0.75 to 200 Amps Price 120.96 147.52
SENSOR
Protects against high/low voltage and rapid system recycling, 95270 Vac operation and adjustable anti shortcycle timer. Integral anti short-cycle protection "delay on break" circuit provides adjustable (.110 minute) lockout delay to prevent rapid system recycling Contact rating: SPDT 5 amps @ 240 Vac Voltage dropout: 12% Voltage pickup: 8%
Part No. ICM491C Description Single Phase Monitor Price 64.66
Application: Detect belt loss, coupling shear and motor failure; ideal for fan and pump status
H608
Replace pressure switches-mechanical devices Verify lighting circuit loads and run times Monitor critical motors Monitor industrial process equipment status Features: Output status LEDs for easy setup and local indication 100% solid state; no mechanical parts Adjustable setpoint Output amps rated at 30 Vac/Vdc
Part No. H608 908H Input Range 1.25 to 50 Amps 2.5 to 135 Amps Price 134.20 125.00
Output 30 Vac/dc; 0.4 Amps Max (Terminal Strip, Accepts #14-22 AWG Wire)
Price 71.86
SENSOR
RP50 Part No. 102A 201A 250A Description 3-Phase Voltage Monitor, Panel Mount 3-Phase Voltage Monitor, 8-Pin Socket mount 3-Phase Voltage Monitor, Panel Mount Switch SPDT SPDT DPDT Price 375.16 264.82 446.86 Part No. RP50 RP51
Senses air handler motor amperage to initiate humidifier or electronic air cleaner operation Requires minimum 4 amps to activate relay
Voltage 24 120 Price 56.03 70.36
1071
Auto-ranging, dual-range voltage monitor that protects 190-480 VAC, 50/60Hz motors regardless of size. The product provides a user selectable 201A nominal voltage setpoint and the voltage monitor automatically selects between the 200V and 400V range. Includes advanced single LED diagnostics. Five different light patterns distinguish between faults and normal conditions. This unique microcontroller-based voltage and phase-sensing device constantly monitors the 3-phase voltages to detect harmful power line conditions. When a harmful condition is detected, the MotorSavers output relay is deactivated after a specified trip delay. The output relay reactivates after power line conditions return to acceptable levels. Low voltage trip, single-phase trip, reverse-phase trip High voltage trip for 250A (optional for 102A, 201A) Fixed 6% voltage unbalance trip 10A @ 240VAC General Purpose Adjustable or manual restart delay (102A and 250A only)
Operating Temperature: -30 to 140F Max Sense Voltage: 600 Vac Adjustable threshold Mounting/Installation: removable mounting tab provided. The wire clamp locks against the load wire, securing the unit in place.
The Hawkeye 735 Series is the ideal solution for the automation installer. It combines a current switch and relay into a single package, reducing the space required for total control of fans and pumps. The integral current switch and relay operate independently of one another. H735 facilitates the functions of start/stop and status with one device instead of two.
Applications Starting/stopping and monitoring positive status of fan and pump motors Replaces pressure switches and other electromechanical devices Features Reduces number of components installed; fits better in small starter enclosures Commands relay and status in a single unit Replaces pressure switches and other electromechanical devices Detects belt loss and motor failure...ideal for fan and pump status
Price 132.00
SENSOR ASSEMBLY
The X Series contains current sensors with or without a 10 or 20 amp relay. An internal 10 amp relay can be used to activate an external contactor, and RIBXLSRA currents up to 150 amps are sensed externally with a solid or split current sensing ring. Other units control and sense up to 20 amp loads, without the use of an external current ring, greatly reducing installation time. Externally visible LEDs indicate the status of the relay coil and current sensor trigger.
Part No. RIBXKF RIBX24SBA RIBXLSRA Description Sensor Internal Sensor/Relay External Sensor/Relay Input Range 0.25 to 150 A 0.50 to 20 A 1.25 to 150 A Switch SPNO SPST SPST
Sensor-relay X Series models have been packaged to save the installer the time, trouble and expense of buying separate components (current sensor, relay, LED indicator, socket, mounting rail and housing) and assembling them on the job or at the shop. Adjustable threshold for sensor/relay combinations, fixed threshold for solid core sensor RIBXKF
TRANSFORMER
FOOT MOUNT NEMA STANDARD
AT87A1155 Power Rating (VA) 50 48 48 Primary Voltage (Vac) 120/208/240 480 277 Secondary Voltage (Vac) 24 24 24
Comment Screw Terminal Secondary 12" Lead Secondary 12" Lead Secondary
FOOT MOUNT
AT88A1005 Power (VA) 75 75 75 Primary Voltage (Vac) 120 208/240 480 Secondary Voltage (Vac) 24 24 24
1072
MULTI-MOUNT
CIRCUIT BREAKER
9" lead wire primary connection Screw terminal secondary connection Foot, plate (2" x 4" or 4" x 4" outlet box) clamp or panel mounting 60 Hz only
Power Part No. AT140A1000 AT140A1018 AT150A1007 AT175A1008 (VA) 40 40 50 75 Primary Voltage (Vac) 120 120/208/240 120/208/240 120/208/240 Secondary Voltage (Vac) 24 24 24 24 Price 26.00 28.58 32.46 71.60
Intended for use in systems with predictable, uniform loads. Includes button for manually resetting the circuit breaker. Foot mounted
Primary Voltage (Vac) 120/208/240 208/277/480 120/208/240 208/277/480 Secondary Voltage (Vac) 24 24 24 24 Price 58.36 59.30 91.56 91.98
FOOT MOUNTED
JOHNSON CONTROL
Open construction, wire leads. Safety agency approved Inherently limited design provides protection from short circuiting
4031F Power (VA) 20 40 40 50 50 100 Primary Voltage (Vac) 120/208/240 120/208/240 277 120/208/240 120/208/240 208-240 Secondary Voltage (Vac) 24 24 24 24 24/12/2.5 120/24
Y65 Series transformers have energy limiting overload protection ONLY; all others have integral circuit breakers Y65G130 is a low voltage isolation transformer for sensitive digital circuitry
Voltage (Vac) Primary Secondary Mounting 24 24 Foot 120/208-240 24 Plate 277/480 24 Plate 120/208-240 24 Plate 277/480 24 Plate 120/208-240 24 Foot 277/480 24 Foot 120/208-240 24 Plate
Price 18.76 25.60 19.74 26.88 33.42 121.12 Part No. Y65G130 Y65T420 Y65F420 Y63T220 Y63F220 Y66T120 Y66F120 Y64T220 Power (Va) 40 40 40 50 50 75 75 92
7541C
CIRCUIT BREAKER
All models feature a UL recognized manual reset circuit breaker Safety agency approved Foot mounted
Relay: 24 VAC, 60 Hz Class 2 , not wet Class B insulation Metal Enclosure Replaceable relay
CONTROLS & ELECTRICAL ACCESSORIES
MULTI-MOUNT
5031M
Closed construction, 4" x 4" plate. Optional 3-way mounting for maximum flexibility: foot, plate or conduit Safety agency approved Welded laminations for quiet operation
ENCLOSED RELAY
Provides low voltage control of line voltage fan motors and auxiliary circuits in heating, cooling or heatingcooling circuits. Enclosed relay Power contact rating: 6.9 FL amps @ 240 Vac
Switch R8239A1052 SPDT R8239B1076 DPDT Part No. Power (VA) 40 50 Primary Voltage (Vac) 120 120/208/240 Secondary Voltage (Vac) Price 26.5 84.46 26.5 116.5
(VA) 40 50 75
In-Line Fuse
1073
OPEN RELAY
Switch DPDT
OPEN RELAY
Coil Part No. 90343 90345 90346 90348 Pole Usage Power-Pilot Power-Pilot Pilot-Pilot Pilot-Pilot Voltage 24 208/240 24 208/240 Price 22.22 29.08 21.68 27.36
Switching SPDT
GENERAL PURPOSE
Price 55.70
RELAY , SWITCHING
SPNO
Provides general purpose and heavy duty switching for refrigeration and air conditioning equipment, appliances, vending machines and similar R8222N1011 applications. Power poles: 6 full load amps @ 277 Vac Pilot poles: 125 VA @ 480 Vac R4228: 12 full load amps @ 277 Vac
Poles Coil B None Power Pilot Power None Power Power Pilot Power Voltage 24 24 24 24 120 120 240 120 24 Price 29.68 31.48 33.28 34.86 32.68 34.06 35.58 50.34 46.60 Part No. Switch SPDT DPDT DPDT DPDT SPDT DPDT DPDT DPDT SPDT A Power Power Pilot Pilot Power Power Power Pilot Power
R8222B1067 Price 14.16 16.06 16.06 R8222D1014 R8222N1011 R8222V1003 R4222B1082 R4222D1013 R4222D1021 R4222N1002 R8228B1012
SPDT
1074
80-second delay on break. Combination electronic time delay board and R8222 relay saves wiring time.
43056
Molded terminal numbers and circuit diagram on top of relay and letter-coded terminals on time delay board provide easy identification for wiring and system checkout. Laminated magnet construction for high efficiency. Reduces stratification and saves energy. Contact ratings: 6 FLA @ 240 Vac
Part No. ST82D1004 Switch DPDT Coil Voltage (Vac) 24 FLA @ 240V 6 Price 53.06
Switch Part No. 43053 43056 43057 43058 43063 43066 43067 43068 Type DPDT 3PDT 3PDT 3PDT DPDT 3PDT 3PDT 3PDT
Mount Type Bracket Bracket Bracket Bracket Plug In Plug In Plug In Plug In Price 62.40 74.36 74.36 78.40 65.14 77.06 77.06 79.60
ELECTRIC HEAT
R8229A1005
Provides conventional on-off control of heating elements and fan in an electric furnace. Maximum temperature rating: 165F Coil voltage: 24 Vac
1st Pole Resistive Amps (@ 277 Vac) 25 25 48
ENCLOSED
Number 5 kW Elements Includes Price 2 108.50 2 Mounting Plate, Hardware 140.70 4 Mounting Plate, Hardware 166.74
HEAVY DUTY
RH series uses silver cadmium oxide contacts to help reduce voltage arcing. Available in 1 to 4 poles, with either .187" blade plug-in (stock) or PCB RH3B terminals (special order). Options include manual check buttons, LED indicators, and top flange covers for direct surface mounting. All models carry worldwide approvals including UL, CSA, TUV and CE. Using a standard terminal arrangement, the RH series will plug into many competitors' sockets. Compact midget size saves space High switching capacity LAC, ULAC models feature indicator light, RH3BULCAC24V has indicator light and momentary check button
Switch Part No. RH1BUAC24V Type SPDT SPDT SPDT SPDT DPDT DPDT DPDT DPDT DPDT 3PDT 3PDT 3PDT 3PDT 4PDT 4PDT 4PDT Coil Voltage 24 24 120 120 24 24 120 120 240 24 24 120 240 24 120 120 Resistive Amps @ 240V 10 10 10 10 10 10 10 10 10 7.5 7.5 7.5 7.5 7.5 7.5 7.5 Price 15.50 18.04 17.32 20.40 35.38 20.60 28.30 20.80 28.50 26.78 45.46 26.76 30.50 33.00 42.40 49.68
90370 Switch Type SPNO SPDT SPDT SPDT SPNO-SPNC SPNO-SPNC Full Load Amps @ 240V 8 8 8 8 8 8 Coil Voltage 208/240 24 120 208/240 24 120
RH1BLAC24V RH1BUAC120V Price 23.42 15.34 21.42 22.94 15.34 26.64 RH1BLAC120V RH2BUAC24V RH2BULAC24V RH2BUAC120V RH2BULAC120V RH2BULAC240V RH3BULAC24V RH3BULCAC24V RH3BULAC120V RH3BULAC240V RH4BULAC24V RH4BUAC120V RH4BULAC120V
EXPOSED CONTACTS
Potter & Brumfield "PR" replacement for motor starting circuits to 1 Hp, 50/60 Hz.
43015 Switch Part No. 43015 43016 Type DPDT Full Load Amps @ 240V 25 Description Metal Dust Cover 19.90 Coil Voltage 240 Price 69.80
1075
Worldwide Approvals: UL, CSA, TUV, CE UL94-V0 flame resistant material Unbreakable nylon construction SH4B05 Hold-down springs and clips available for most models Receptacles with four contact points per blade
Part No. SH1B05 SH2B0205 SH3B05 SH4B05 Description Socket, DIN/Surface mount, RH1B Socket, Surface mount, RH2B Socket, DIN/Surface mount, RH3B, RH2LB Socket, DIN/Surface mount, RH4B Price 8.44 10.62 11.74 25.52
17015 Switch Type SPST SPDT Full Load Amps 18 18 Coil Voltage 24 24
ADD-A-RELAY
R8225A1017
Provides control of line voltage fan motors and auxiliary circuits in heating, cooling or heating-cooling systems. Contact rating: 7.0 FL amps @ 240 Vac Auxiliary rating: 2.0 FL amps @ 240 Vac Coil voltage: 24 Vac
Switch SPDT DPST, Normally Open, 1-Main, 1-Auxiliary Price 101.42 118.42
17002 Full Load Part No. 17002 17004 Amps 18 18 Coil Voltage 24 120 Price 67.86 80.94
HEAVY DUTY
Provides switching for high-current loads such as cooling compressors. Contact rating: 10 full load amps @ 240 Vac Integral transformer for control circuit Coil voltage: 24V
Input Part No. R847A1085 Voltage 120 Switch DPST Price 185.28
RIBU1S Part No. RIBU1C RIBU2C RIBU1S RIBU1SM RIBU1S NC RIBH1S RIBH1C RIB2401D RIB2401B RIB24P RIB243P RIB01P RIB02P
In enclosed plastic box All wires exiting from nipple Selected models have override switch which allows manual control of switching action Pilot duty rated at 277 Vac RIBU1SM is set up to send a switch monitoring signal to a controller
Coil Voltage 1030 ac/dc, 120 ac 1030 ac/dc, 120 ac 1030 ac/dc, 120 ac 1030 ac/dc, 120 ac 1030 ac/dc, 120 ac 1030 ac/dc, 208/240/277 ac 1030 ac/dc, 208/240/277 ac 24 ac/dc, 120 ac 24 ac/dc, 120 ac 24 ac/dc 24 ac/dc 120 ac 208/240/277 ac Switch SPDT 2-SPDT SPNO SPNO SPNC SPNO SPDT DPDT SPDT DPDT 3PNO DPDT DPDT Resistive Amps (A) 10 10 10 10 10 10 10 10 20 20 20 20 20 Inductive Load (VA) 480 480 480 480 480 480 480 180 1110 1110 1110 1110 1110 Override Switch Yes Yes Yes Yes Price 28.62 52.38 41.00 52.92 41.00 47.52 32.08 47.78 42.44 65.02 96.12 74.38 77.22
1076
Panel style relays are exposed track mount suitable for wiring enclosures. Selected models have override switch which allows manual control of switching action
RIBM24S Part No. RIBMU1C RIBMU2C RIBM24C RIBM24S1
1
Coil Voltage 1030 ac/dc, 120 ac 1030 ac/dc, 120 ac 24 ac/dc 24 ac/dc
T style relays have a class 2 wiring compartment with terminal strips for high/low voltage separation. Wires exit from nipple
Switch SPDT
Override Switch
Price 41.32
RELAY BOARD
Designed for fan speed control but usable with any 10 amp resistive load. Includes two independent 20 amp relays and a Class II transformer for low voltage controls.
Description 2 Speed Fan 2 Speed Fan 3 Speed Fan 3 Speed Fan 3 Speed Fan
ELECTRIC HEAT
ELECTRIC HEAT
Primary Part No. R841C1227 Switch SPST DPST Voltage 240 240 Application Controls 1 Load, Integral Transformer Controls 2 Loads, Integral Transformer Price 130.20 265.78
Resistive Load 25A, 6000W, 240V 22A, 6000W, 277V Price 125.10 137.40
R841E1068
SWITCHING RELAY
Provides intermediate switching of a line voltage device from a low voltage controller. Integral transformer provides low voltage power for control circuit
Switch SPDT + PowerPile rated low voltage SPST relay SPST DPST DPST
Application 1-Line Voltage Load, 1-Low/Millivolt Load, 2- or 3-Wire Control 1-Line Voltage Load, 2-Wire Control 1-Line Voltage Load, 1-Low/Millivolt Load, 2-Wire Control 1-Line Voltage Load, 1 Low Voltage Load
F.L. Amps 15 @ 120 Vac 5.1 @ 240 Vac 3.7 @ 240 Vac
1077
Level-temp low voltage control systems for electric heat Level-temp allows low voltage 2-wire thermostats to control line voltage loads such as baseboard heaters. Switch: SPST, normally open
Use with 2-wire, 24 Vac thermostat to control electric heating equipment such as baseboards, ceiling cables and duct heaters.
C25GNF* features: 100% increase in electrical and mechanical life - 200,000 and 500,000 operations C25DNF340 RoHS compliance Load-side coil quick connection for easy installation Panel space savings due to shallower depth cULus certification
Part No. C25DND325T C25DND325A C25DND325B C25DND330T C25DND330A C25DND330B C25DNF330T C25DNF330A C25DNF330B C25DNF340T C25DNF340A C25DNF340H C25DNF340B C25DNF340C C25DNJ350T C25DNJ350A C25DNJ350B C25FNF360T C25FNF360A C25FNF360B C25FNF375A C25FNF375B C25FNF375C C25GNF390T C25GNF390A C25GNF390B C25HNE3120A C25HNE3120B Full Load Amps 25 25 25 30 30 30 30 30 30 40 40 40 40 40 50 50 50 60 60 60 75 75 75 90 90 90 120 120 Coil Voltage 24 110/120 208/240 24 110/120 208/240 24 110/120 208/240 24 110/120 277 208/240 440/480 24 110/120 208/240 24 110/120 208/240 110/120 208/240 440/480 24 110/120 208/240 110/120 208/240 Power Terminals D D D D D D F F F F F F F F J J J F F F F F F F F F E E Price 40.90 40.90 40.90 39.10 38.94 39.10 40.90 40.90 40.90 41.82 41.82 49.92 41.82 43.02 70.90 70.90 70.90 126.36 125.46 125.46 178.18 178.18 178.18 231.10 232.72 232.72 490.90 490.90
Power Terminals B B B B B B
COMPACT 2 POLE
C25BNF240 Part No. C25BNB220T C25BNB220A C25BNB220B C25BNB225T C25BNB225A Full Load Amps 20 20 20 25 25 30 30 30 30 30 40 40 40 40 Coil Voltage 24 110/120 208/240 24 110/120 24 110/120 208/240 277 480 24 24 110/120 208/240 Power Terminals B B B B B B B B B B B F B B Price 18.54 18.54 18.54 20.14 19.46 20.54 20.54 20.54 21.64 21.28 28.54 30.00 27.68 27.68
4 POLE
Part No. C25END430T C25END430A C25END430B C25ENF440T C25ENF440A C25ENF440B Full Load Amps 30 30 30 40 40 40 Coil Voltage 24 110/120 208/240 24 110/120 208/240 Power Terminals D D D F F F Price 84.54 85.46 84.90 90.00 90.00 87.32
2 POLE
Part No. C25DND230B C25DNF240T Full Load Amps 30 40 Coil Voltage 220 24 Power Terminals D F Price 129.74 41.82
1078
C320KG3
C320DPG* features: 100% increase in electrical and mechanical life - 200,000 and 500,000 operations RoHS compliance cULus certification Panel space savings due to shallower depth Load-side coil quick connection for easy installation
Use With 15-75 Amps Contactor 15-75 Amps Contactor 90 Amps Contactor 90 Amps Contactor 90 Amps Contactor 120-360 Amps Contactor 120-360 Amps Contactor 120-360 Amps Contactor 120 Amps Contactor 120 Amps Contactor Type 1-NO 1-NO 1-NC 1-NC 1-NO 1-NO 1-NC 1-NO 1-NC 1-NO 1-NC 1-NO 1-NO 1-NC Circuit With Standard Pressure Plate Terminals With Standard Pressure Plate Terminals With Pressure Plate and Quick Connect Terminals With Pressure Plate and Quick Connect Terminals With Pressure Plate and Quick Connect Terminals With Standard Pressure Plate Terminals With Standard Pressure Plate Terminals With Standard Pressure Plate Terminals N/A With Standard Pressure Plate Terminals Price 18.72 22.72 41.82 41.82 61.82 78.94 78.94 121.34 78.94 121.34
Part No. C320KG1 C320KG3 F1C320DPG01 F1C320DPG10 F1C320DPG11 C320KGS20 C320KGS21 C320KGS22 C320KGS31 C320KGS32
SURESWITCH RELAY
Universal electronic upgrade for mechanical compressor contactors: 5x contactor life, sealed to keep out ants and debris.
Price 21.68 21.68
C320SNP11 Part No. C320SNP11 C320SNP22 Amps 15-75 15-75 Type 1-NO 1-NC 2-NO 2-NC
REPLACEMENT COIL
931586 Part No. 931856 9 3185 1 931852 9 3186 1 9 3079 3 932566 9 3256 1 932562 927562 Class 15-40A, 2 and 3 Pole (Series D1) 15-40A, 2 and 3 Pole (Series D1) 15-40A, 2 and 3 Pole (Series D1) 50A, 2 and 3 Pole (Series D1) 60-70A, 2 and 3 Pole, 25-40A, 4 Pole 60-75A, 2 and 3 Pole, 25-40A, 4 Pole 60-75A, 2 and 3 Pole, 25-40A, 4 Pole 60-75A, 2 and 3 Pole, 25-40A, 4 Pole 90A, 2 and 3 Pole Coil Voltage 24 110/120 208/240 110/120 104/120 24 104/120 208/240 208/240 Price 20.00 20.00 20.00 20.00 84.02 30.00 30.00 30.00 456.54
Microprocessor controlled sealed compressor switching Line voltage brownout protection Short cycle protection Tricolor LED displays Heavy-duty lug connectors Zero chatter latching relay Four-hole mounting matches mechanical contactors Random start delay on power up and brownout recovery Compressor test and cycle count by push-button Microprocessor controlled switching algorithms reduce arcing, virtually eliminating contact pitting and welding.
Coil Voltage 24
Price 93.32
1079
AUXILIARY SWITCH
912000117 Part No. 912000112 912000113 912000116 912000117 912000118 912000120 912000121 Application 15 to 75 Amp 15 to 75 Amp 90 Amp 90 Amp 90 Amp 120 to 360 Amp 120 to 360 Amp Switch 1 NO/1 NC 2 NO 1 NC 1 NO/1 NC 2 NO 1 NC 1 NO/1 NC Price 56.00 56.00 44.46 57.70 57.70 90.70 105.06
3 POLE, 50 TO 90 AMPS
3 POLE
Part No. 912302500 912302501 912302502 912303000 912303001 912303002 912304000 912304001 912304002 912305000 912305001 912305002 912306001 912306002 912307501 912307502 912309001 912309002 912312001 912312002 912320001 912320002
60 Hz only
2 POLE
1080
4 POLE
3 POLE
1081
1082
1083
1084
1085
1086
1087
1088
Class 14 industrial magnetic starters are designed for across the line starting of single phase and polyphase motors. Across the line or full voltage starting is 14CSD32AA used when motor starting torque can be applied safely and current inrush does not produce an objectional voltage drop. All starters are supplied with a NO holding interlock that in conjunction with an appropriate pilot device will provide low voltage protection or release. ESP200 starters (14*U models only; 14*S models provide ESP100 overloads) combine the rugged NEMA contactors with a state of the art solid state overload that provides phase loss, phase unbalance ground fault protection. It offers the user greater motor protection and extended life in heavy duty applications. The ESP200 ultimately results in a cost savings to the user. Standard Features True phase loss protection; trips within 3 seconds Phase unbalanced prevents motor running inefficiently Ground fault trip when selected Selectable trip class 5, 10, 20 or 30 Reset trip can be selected Auto/Manual restart Easy to select and use, Dip Switch selectable Overload is self powered, no need for external power source
Part No. 14CSD32AA 14CSD32BA 14CUB32AA 14CUB32BA 14CUC32AA 14CUC32BA 14CUC32BJ 14CUD32BA 14DSE32AA 14DSE32BA 14DUC32AA 14DUC32BA 14DUD32AA 14DUD32BA 14DUE32AC 14DUE32BA 14EUE32AA 14EUE32BA 14FUF32BA 14GUG32AA 14GUG32BA 14HUG32AA 14HUG32BA Enclosure Open NEMA 1 Open NEMA 1 Open NEMA 1 NEMA 1 NEMA 1 Open NEMA 1 Open NEMA 1 Open NEMA 1 Open NEMA 1 Open NEMA 1 NEMA 1 Open NEMA 1 Open NEMA 1 Size 0 0 0 0 0 0 0 0 1 1 1 1 1 1 1 1 1 3/4 1 3/4 2 2 1/2 2 1/2 3 3 Amps Coil Voltage (Vac) 2.510A 120/240 2.510A 120/240 0.753.4A 120/240 0.753.4A 120/240 312A 120/240 312A 120/240 312A 24 5.522A 120/240 918A 120/240 918A 120/240 312A 120/240 312A 120/240 5.522A 120/240 5.522A 110/240 1040A 220/440 1040A 120/240 1040A 110/240 1327A 110/240 1352A 110/240 25100A 120/240 25100A 120/240 25100A 120/240 25100A 120/240 Price 571.18 600.12 660.10 675.14 660.10 675.14 675.14 675.44 645.16 677.36 750.32 762.36 750.32 762.36 750.32 762.36 993.90 1010.44 1429.96 1810.36 1879.54 2001.34 2329.14
75DF14
Kit includes 1 pole stationary and movable contacts and contact springs. Use with Models P or S (4th position in part#)
Fits classes 14, 17, 18, 22, 25, 26, 30, 32, 40, 43, 83, 84, 87, 88
Part No. 75DF14 75FP14 75HF14 NEMA Size 1 2 3 Price 600.12 600.12 677.36
AC COIL
Use with Models P or S (4th position in part#) Fits classes 14, 17, 18, 22, 25, 26, 30, 32, 40, 43
NEMA Size 00 - 2.5 00 - 2.5 00 - 2.5 Voltage (Vac) 24 110-120/220-240 220-240/440-480 Price 169.94 169.94 169.94
ACCESSORIES
49SBP5
49AB01
Push buttons and selector switches for NEMA 1 enclosures only; Class 14, 40 and LEN Auxiliary switches universally fit classes 14, 17, 18, 22, 25, 26, 30, 32, 36, 37, 40, 43, 83, 84, 87, 88
Part No. 49AB10 49AB01 49SBPB5 49SBSB1 49SBSB4 Class Auxiliary switch, SPNO Auxiliary switch, SPNC Push button, start/stop, NEMA 1 Hand-Off-Auto selector switch, NEMA 1 Off-On selector switch, NEMA 1 Amps 00 to 4 00 to 4 00 to 4 00 to 4 00 to 4 Price 33.10 33.10 133.60 133.60 133.60
MOTOR ASSISTS/RELAYS
CURRENT RELAY
One size for all compressors from 1/121/2 horsepower These two solid state relays will replace all current type relays Can be used with or without a start capacitor
Part No. ICG1 Voltage (Vac) 120 Price 9.96
1089
One size for all compressors from 1/121/2 horsepower Replaces all push-on current type relays P0115 For use on compressors with "pin type" terminals Can be used on all capacitor and noncapacitor start motors
Part No. P0115 P0230 Voltage (Vac) 115 230 Price 11.04 12.04
Designed to be the most reliable and efficient starting capacitor in its class Protection timing circuit Instantaneous starting HS206 Voltage monitoring Compressor leads with flag terminals Solid state design UL recognized
Part No. HS206 HS207 HS210 Horsepower 1/4-1/3 1/12-1/5 1/12-1/2 Voltage (Vac) 115 115 115 Price 16.94 16.94 27.00
RELAY OVERLOAD
R041
Relay & overload in one combination unit Prewired for fast, simple installation Superior locked rotor protection eliminates start winding overheating
Horsepower 1/4, 1/3 1/121/5 1/4, 1/3 1/121/5 Voltage (Vac) 115 115 230 230 Price 13.34 13.34 21.40 21.40
RCO410
This all-in-one unit replaces all 3 electrical components, relay, overload and start capacitor, on all capillary systems. For units without run capacitor
Horsepower 1/2 1/4, 1/3 1/121/5 1/2 Voltage (Vac) 115 115 115 230 Price 31.66 22.44 22.44 29.40
Push-on relay overload Quick connect push-on terminals for run and/or start capacitor
Part No. UPRO81 UPRO41 UPRO21 Horsepower 1/12 to 1/5 1/4 to 1/3 1/3 to 1/2 Voltage (Vac) 115 115 115 Price 23.50 23.50 23.14
Push-on compressor terminals, and 1/4" capacitor terminals Designed for modern high efficiency compressors Helps older compressors to start and run cooler Easy mount clip for quick installation Prevents low voltage starting problems Adds a closely matched system run capacitor
Part No. URCO810RC URCO410RC URCO210RC Horsepower 1/12 to 1/5 1/4 to 1/3 1/3 to 1/2 Run Cap (f) 12.5 15 20 Voltage (Vac) 115 115 115 Price 29.16 29.16 35.00
RELAY OVERLOAD/PUSH-ON
RELAY , CAPACITOR
Part No. PR041 Horsepower 1/4, 1/3 Voltage (Vac) 115 Price 16.60
A combined solid state starting relay and capacitor Replaces current type relays Provides added boost for hard start and unbalanced systems
Part No. RSC10 Horsepower 1/121/2 Voltage (Vac) 115 Price 26.24
1090
Price 17.36
For low voltage and hard starting compressors Increases torque 1000% Device includes high current (40A) potential relay and 330Vac start capacitor Senses motor start Instant restart Can be used on 208-265 Vac, single phase compressors
Part No. HT80 HT100 Horsepower 1 to 3 3.5 to 5 Price 72.00 85.00
RELAY , CAPACITOR
For low voltage and hard starting compressors Room air conditioning units Residential and commercial PSC air conditioning units and heat pumps For all PSC air conditioning units from 4,000 through 120,000 BTU's (1/210 horsepower) Can be used on 120288 Vac units
Part No. SPP5 SPP6 Increased Torque (Oz. -In.) 270 390 Price 15.84 24.16
3W2
The 3 Series Hard Starts provide the service professional with an OEM option when the application calls for a hard start.
RELAY , CAPACITOR
Voltage sensing Instant re-start 35 amp relay contacts For use on all 208/240 V single phase compressors, scroll, reciprocating compressors and single or dual run capacitors 208/240 volts Includes EZ snap bracket for quick installation
Part No. Horsepower 1 to 3 3.5 to 4.5 4 to 5 Capacitor 88 - 108 F; 330V 189 - 227 F; 330V 270 - 324 F; 330V Price 48.34 55.00 65.00 3W1 3W2 3W3
HS195 Part No. HS195 HS196 Usage 120-288V, 1/2 to 5 HP 120-288V, 1/2 to 10 HP Price 12.96 19.00
ULTRASTART
The SUPCO E-Class Series comprise the most advanced developments in start device technology:
SPP8E
Part No. HT80 Price 48.24 38.34 44.16 60.00 60.84 93.34 HT100
Horsepower 1 to 3 3.5 to 5
Usage 90-130V, 1/8 to 1 HP 90-277V, 1/3 to 2 HP 90-277V, 1/2 to 3 HP 90-277V, 1 to 4 HP 90-277V, 1 HP and up 90-277V, 3 HP and up
This package combines a powerful starter Power Pak (to provide increased starting torque), and an adjustable "Delay on Break" time delay (to prevent compressor short cycling). Adjustable time delay from 6 seconds to 5 minutes Can be used on 115288 Vac units
Part No. SPP5TD Increased Torque (Oz.-In.) 270 Price 39.26
Electronic potential relay technology Backup electronic timing circuit to protect the compressor Voltage sensing Instant re-start Easy 2-wire connection
Incorporating OEM approved technology, the UltraStart hard start kits provide reliable starting ability for all single phase compressors. Maximum performance and productivity with an easy 2-wire installation. For use on all single phase reciprocating, scroll and rotary compressors; 208V, 230V and 265V
1091
APR5 allows the exact wire by wire replacement of virtually all potential relays on the market. The patented state-of-the-art electronic circuitry also provides additional motor protection. The contacts of the APR5 will open after 11 1/2 seconds if the motor does not start for any reason. This important safety feature prevents the start winding from overloading during a locked rotor condition by removing it from the circuit. You can preset the pick-up voltage of the APR5 to the voltage of the defective relay.
Part No. APR5 Pick-up Voltage (Vac) 130370 Price 46.50
APR5 allows the exact wire by wire replacement of virtually all potential relays on the market. The patented state-of-the-art electronic circuitry also provides additional motor protection. The contacts of the APR5 will open after 11 1/2 seconds if the motor does not start for any reason. This important safety feature prevents the start winding from overloading during a locked rotor condition by removing it from the circuit. You can preset the pick-up voltage of the APR5 to the voltage of the defective relay.
Part No. APR5 Pick-up Voltage (Vac) 130370 Price 46.50
19163
SUPR is a time function potential relay designed to be a wire-to-wire replacement for virtually any potential relay on the market. It can be used on any single phase motor or air conditioning and refrigeration compressor up to 5 hp. Operating voltage: 110270 vac, single phase Start time: 0.5 0.1 seconds Terminals: screw on; push-on adapters provided
Part No. SUPR Description Universal Potential Relay Price 39.84
MARS Part No. 19163 19164 19165 19166 19167 19168 19169 19170 19171 No. 63 64 65 66 67 68 69 70 71
Continuous Coil Voltage 170 395 332 395 420 502 336 253 420
Pick-Up Min. 139 260 168 215 295 325 180 285 212 Max. 153 275 182 225 315 345 195 305 232
Drop-Out Max. 55 120 90 120 125 135 105 77 121 Price 24.00 24.00 24.00 24.00 24.00 24.00 24.00 24.00 24.00
19004
UNIVERSAL CURRENT
Part No. 19002 19003 19004 19005 19006 19007 19008 19009 19010
MARS No. 63 64 65 66 67 68 69 70 71
Continuous Coil Voltage 170 395 332 395 420 502 336 253 420
Pick-Up Min. Max. 139 153 260 275 168 182 215 225 295 315 325 345 180 195 285 305 212 232
Price 70.66 77.14 74.26 77.14 80.06 84.54 74.26 73.26 80.06 Part No. 27001 27002 27003 27004 27005 27006 27007 27008 27009 27010 27011 27012
Amps Max. Pick-Up 3.8 5.2 6.8 8.3 10.5 11.8 13.8 15.1 16.8 22.5 25.4 31.0 Min. Drop-Out 3.2 4.4 5.8 7.1 8.7 9.8 11.5 12.6 14.0 18.0 20.3 25.0
Most Commonly Used Horsepower @ 115V 1/12 1/8 1/8, 1/6, 1/5 1/6, 1/5, 1/4 1/5, 1/4 1/5, 1/4, 1/3 1/4, 1/3 1/4, 1/3, 1/2 1/3, 1/2 1/3, 1/2 1/3, 1/2, 3/4 1/2, 3/4 Price 26.24 25.46 26.24 24.74 24.74 24.74 24.74 24.74 24.74 24.74 26.24 24.74
1092
CAPACITOR
RUN, 370 VOLT
35001
Used in refrigeration, room air conditioners, heating, appliances and electric motors. 3/4" diameter
Application Survey, HP
CR2X370 Part No. Value (f) 2 3 4 5 6 7.5 10 12.5 15 17.5 20 25 30 35 40 45 50 70 80 Price 4.44 5.24 4.76 4.58 5.88 5.82 5.96 9.06 9.48 10.66 10.94 11.04 14.90 15.00 20.58 22.58 24.00 21.40 25.24
Part No. 35001 35003 35004 35006 35009 35010 35011 35012 35014 35015 35016 35018 35019
115V 1/20 1/20, 1/12 1/12 1/12, 1/8 1/8, 1/6, 1/5 1/8, 1/6, 1/5, 1/4 1/6, 1/5, 1/4 1/6, 1/5, 1/4 1/5, 1/4 1/5, 1/4, 1/3 1/5, 1/4, 1/3 1/4, 1/3, 1/2 1/3, 1/2
230V 1/12, 1/8, 1/6 1/6, 1/5, 1/4 1/5, 1/4, 1/3 1/4, 1/3 1/3, 1/2 1/3, 1/2 1/3, 1/2 1/3, 1/2 1/2 1/2 1/2 1
Price 18.06 18.06 18.60 18.60 18.10 17.54 18.60 18.60 18.60 17.54 17.54 17.54 17.54
CR2X370 CR3X370 CR4X370 CR5X370 CR6X370 CR7.5X370 CR10X370 CR12.5X370 CR15X370 CR17.5X370 CR20X370 CR25X370 CR30X370 CR35X370 CR40X370 CR45X370 CR50X370 CR70X370 CR80X370
OVERLOAD
OV36 Locked Rotor Amps 12.013.5 14.015.5 16.018.0 18.522.0 22.526.5 27.031.0 31.535.5 36.040.0 40.544.5 45.049.0 Normal Usage Type Condenser Fan, Static Fan Fan, Static Fan, Static Static Fan Static Fan Static Fan
Part No. OV32 OV34 OV36 OV38 OV40 OV42 OV44 OV46 OV48 OV50
1" DIAMETER
36011 Typical Part No. 36010 36011 36012 Application, HP 1/2 3/4, 1 1 Voltage 115 230 208/230 Price 46.34 46.34 46.34
1093
CD60/5X370R Value (f) Part No. CD20/5X370R CD25/5X370R CD30/3X370R CD30/5X370R CD35/5X370R CD40/5X370R CD40/7.5X370R CD45/5X370R CD50/3X370R CD50/5X370R CD55/5X370R CD60/5X370R CD70/5X370R CD80/5X370R CD80/7.5X370R CD80/10X370R 1 20 25 30 30 35 40 40 45 50 50 55 60 70 80 80 80 2 5 5 3 5 5 5 7.5 5 3 5 5 5 5 5 7.5 10 Price 16.60 15.46 21.72 22.32 23.00 25.52 26.50 25.32 23.56 22.70 22.96 25.06 31.94 26.92 37.64 38.70
DUAL CAPACITOR
Used primarily to serve two separate applications. May be connected in parallel to obtain other ratings.
CD355X440
1094
Round body
Part No. CS30X110 CS36X110 CS43X110 CS88X110 CS108X110 CS124X110 CS130X110 CS145X110 CS161X110 CS189X110 CS200X110 CS216X110 CS233X110 CS270X110 CS300X110 CS324X110 CS340X110 CS378X110 CS400X110 CS430X110 CS460X110 CS540X110 CS590X110 CS708X110 CS1000X110
UNIVERSAL
Description Turbo200 Run Capacitor Replacement, 2.5/5/5/10/20/25 f Turbo200X Run Capacitor Replacement, 5/5/7.5/10/20/50 f
1095
The world's first multiple tapped, fluidfilled, metal can, motor-run capacitor, which eliminates the need to inventory more than 200 individual single or dual value capacitors. Replaces 370V or 440V capacitors Each part comes individually boxed, including 5 jumper wires. The Turbo200 is manufactured using AmRad Engineering's patented Ultramet capacitor technology, which allows a metallized film capacitor to be tapped with a built-in common or ground connection and eliminates the necessity of separate capacitors or of packaging two or more capacitors in one can.
THERMOSTAT
TUBE MOUNT
CHANGEOVER SWITCH
33430
Maximum load: L, F, D Primary: 10A @ 240V D Secondary: 3A @ 240V Type Code: D = SPDT, L = Open High, F = Open Low Includes listed size clip
Temperature (F) Open Closed 70 20 65 20 35 55 50 35 20 5 20 30 20 60 35 5 50 30 40 20 80 50 80 80 30 30 Tube Size (In.)1 5/8 5/8 3/8 1/2 3/4 3/4 5/8 5/8 5/8 5/8 5/8 3/8 1/2 Temp Code D70-5 D65-4.5 F55-2 D50-1.5 L20-1.5 F30-1 F60-4 L35-3 L50-2 L40-2 L80-3 L80-5 L80-5 Price 61.34 65.50 59.66 72.64 79.80 45.20 51.76 65.42 84.86 83.66 132.84 31.32 31.32
For summer-winter changeover in hydronic heat/cool fan coil units. SPDT switch Contact rating: Term 1 and 3, 25A @ 240V Term 1 and 2, 5A @ 240V
Temperature (F) Open Closed 88 73
Price 45.86
Part No. 33405 33415MA 33420 33430 33435 33440 33455 33460 33470 33475 33480 334902 334922
1
CHANGEOVER SWITCH
Provides automatic changeover of thermostat to permit proper operation of zone valve on combination hot and chilled water systems. Switch: SPDT Contact rating: 3.75 F.L. Amp @ 240 Vac
Temperature Setting (F) 85 Differential (F) 15
Price 73.76
CONSTRUCTION
Low cost single set-point thermostats intended for use as a temporary device to provide heating to allow drywall to dry during construction. 2- wire, 24 volt, 2 amp maximum Accuracy: 5F
Temperature Setting 60F 65F 70F 75F Application Heat Heat Heat Cool Price 12.06 12.06 12.06 15.40
Freeze Protection Control Protects air conditioning evaporator coil from freezing. Opens 35F/Close 50F Replaces: Trol A Temp FPC
Part No. SFPC Description Freeze Protection Control Price 29.84
Snap disc fan controls for regulation of fan or blower. Last three numbers indicate cut-in temperatures on fan controls 3F01130 Switch: SPST, close rise Contact rating: 5 F.L. Amp @ 240 Vac
Part No. Cut In (F) 110 120 130 140 150 160 180 200 350 Cut Out (F) 90 110 115 120 130 140 160 180 320 Differential (F) 20 10 15 20 20 20 20 20 30 Temp Code F110-2 F120-1 F130-1.5 F140-2 F150-2 F160-2 F180-2 F200-2 F350-3 Price 10.42 10.42 10.42 10.42 10.42 10.42 10.42 10.42 10.42
HEATCRAFT REPLACEMENT
1096
3F051
This adjustable snap disc thermostat allows you to vary the temperature setpoint to match your specific needs. Adjustable snap disc controls Switch: SPST, close rise Contact rating: 10 F.L. Amp @ 240 Vac
Snap disc control for high limit safety Switch: SPST, open rise Contact rating: 5 F.L. Amp, 25 Resistive Amp @ 240 Vac
3L01150
Part No. Range Part No. AT021 AT022 AT023 (F) 90 to 130 140 to 180 90 to 130 Differential (F) 20 20 20 Includes 1/4" Q.C terminals 1/4" Q.C terminals 1/4" Q.C terminals Price 20.60 20.60 24.00 3L01120 3L01130 3L01140 3L01150 3L01165 3L01170 3L01180 3L01190 3L01200 3L01230 3L01250 3L01300 3L01350
Cut Out (F) 120 130 140 150 165 170 180 190 200 230 250 300 350
Cut In (F) 110 115 100 110 125 130 140 150 160 190 210 250 310
Differential (F) 10 15 40 40 40 40 40 40 40 40 40 50 40
Temp Code L120-1 L130-1.5 L140-4 L150-4 L165-4 L170-4 L180-4 L190-4 L200-4 L230-4 L250-4 L300-5 L350-4
Price 10.42 10.42 10.42 10.42 10.42 10.42 10.42 10.42 10.42 10.42 10.42 10.42 10.42
LIMIT, ADJUSTABLE
This adjustable snap disc thermostat allows you to set the temperature set point to match your specific needs. Contact rating: 10 F.L. Amp @ 240 Vac Adjustable snap disc controls Switch: SPST, open rise
Range Part No. AT012 AT013 AT014 AT015 (F) 135 to 175 175 to 215 210 to 250 250 to 290 Differential (F) 40 40 40 40 Includes 1/4" Q.C terminals 1/4" Q.C terminals 1/4" Q.C terminals 1/4" Q.C terminals Price 20.60 20.60 20.60 22.34
HIGH LIMIT
Cut Out Part No. 39310 (F) 110 Cut In (F) 90 Differential (F) 20 Temp Code L110-2 Price 30.60
HIGH LIMIT
Switch: SPST, open rise Contact rating: 10 F.L. Amp, 25 Resistive Amp @ 240 Vac Adapter flange plate included
Cut Out Part No. (F) 120 140 150 160 170 Cut In (F) 110 100 110 120 130 Differential (F) 10 40 40 40 40 Price 11.90 11.90 11.90 11.90 11.90
Range Part No. 3L0510 3L0513 (F) 135 to 175 250 to 290
Differential (F) 20 40 Includes Tab to Screw Terminals Tab to Screw Terminals Price 27.08 27.08
Range Part No. 39220 39225 39230 (F) 135 to 175 175 to 215 210 to 250
Differential (F) 40 40 40 Price 27.48 27.48 27.48 3L02160 Part No. 3L02160 3L02170 3L02180 3L02190 3L02200
Switch : SPST, open rise Contact rating : 5 FL Amp, 25 Resistive Amp @ 240 Vac
1097
Switch: SPST, open rise Contact rating: 1.5 F.L. Amp, 10 Resistive Amp @ 240 Vac Terminals: vertical 1/4"
3L03140 Cut Out Part No. SRL135 SRL220 SRL230 SRL240 SRL260 SRL300 SRL350 (F) 135 220 230 240 260 300 350 Replaces Rheem 47-22453-02 Nordyne 626354 Nordyne 626353 Nordyne 626355 Nordyne 626350 Nordyne 626343, Rheem 47-22861-02 Goodman B13701-54 Price 13.76 13.76 13.76 13.76 13.76 13.76 13.76 Part No. 3L03140 3L03190
20F differential
Switch: SPST, open rise Contact rating: 1.5 F.L. Amp, 10 Resistive Amp @ 240 Vac Terminals: 45 angle 1/4"
Part No. SLS140 SLS150 SLS160 SLS170 SLS180 SLS200 Cut Out (F) 140 150 160 170 180 190 Cut In (F) 100 110 120 130 140 150 Differential (F) 40 40 40 40 40 40 Price 11.94 11.94 11.94 11.94 11.94 11.94
OEM REPLACEMENT
HL502 Part No. HL501 HL502 HL503 HL504 HL507 HL508 Close (F) 130 150 150 160 110 170 210 150 130 160 170 Open (F) 170 180 190 240 140 190 240 170 170 200 210 Replaces BDP HH12ZA174A, HH12ZA176A, P331-2203 BDP HH12ZA178A, Carrier B1370001 BDP HH12ZA189, HH12ZB190, HH12ZA193A, P331-2205 BDP HH12ZA240, HH12ZA252A, P331-2217 BDP HH12ZA140, Goodman 87F16, York 025-29041-0055 BDP HH12ZB190, HH12ZA193, HH12ZA189, P331-2005, Carrier B1370913, Lennox 47-21711-03, Trane SWT1260, York 025-29041-006 BDP HH12ZB240, HH12ZA240, HH12ZA252, P331-2217, Carrier B1370903 BDP HH12ZB170, Lennox 47-25350-06 BDP HH12ZB170, Goodman 26H66, Rheem SWT1258 Carrier HH12ZB200, HH12ZA199, HH12ZA201, Goodman 49L03, Lennox 47-25349-05, Trane SWT1260, York 025-29041-006 Carrier HH12ZB210 Price 23.34 23.34 23.34 23.34 23.34 23.34 23.34 23.34 23.34 23.34 23.34
1098
Q103 Number Part No. Q101 Q102 Q103 Q104 Q105 Q106 Q108 Q109 Q114 Timings 1 1 1 1 2 2 1 1 4 Number Switches 1 1 2 2 3 4 1 1 5 Replaces Klixon Number 60000A0M-98 60000A0M-97 60000EOM-84 60000EOM-86 51172-32 51172-33 Price 18.34 18.34 21.16 21.16 34.00 40.84 36.00 28.06 49.00
Direct replacement for most fan/heat sequencing functions Solid-state reliability Ambient rated from -40 to +165F Multi-poise mounting Single load rating @ 240 Vac, 30 resistive Delay times are random between range
Part No. 33243 33246 33247 332551
1
SEQUENCER TIMING*
ON M1-M2 Q101 Q102 Q103 Q104 Q105 Q106 Q108 Q109 Q114 33243 33246 33247 33255 33222 1-20 30-90 1-20 30-90 1-110 1-110 1-25 20-50 1-160 1-3 1-60 1-60 1-24 30-110 M1-M2 1-24 M3-M4 30-70 M5-M6 A1-A2 1-60 1-160 4-5 1-160 1-160 1-20 30-90 1-110 1-110 1-110 1-110 1-110 M3-M4 M5-M6 M7-M8 M1-M2 40-110 1-30 40-110 1-30 1-110 1-110 65-115 40-110 1-160 1-3 1-45 1-45 15-75 15-65 M1-M2 45-75 M3-M4 1-40 M5-M6 A1-A2 1-45 1-160 4-5 1-160 1-160 40-110 1-30 1-110 1-110 1-110 1-110 1-110 OFF M3-M4 M5-M6 M7-M8
One control switches a fan and up to three elements on and off in sequence. Isolated fan switch has positive interlock to assure fan is on when the element is on and fan is off when the last element is off Control voltage: 24 Vac Contact rating: 25A resistive @ 240 Vac
Part No. R8330D1039 Stages 3 Switches 4 Price 248.84 Part No. 33222
Single load rating @ 240 Vac, 30A resistive, all contacts including auxiliary Supply voltage: 24 Vac
Switch Type 2SPST/NO Number Timings 2 Klixon Number 51172-22 Price 56.72
1099
SEQUENCER
SEQUENCER, 2 SWITCH
Each kit contains one close wound, stretch to length, resistance coil with welded terminal bolts; two each male and female ceramic terminal insulators; two each .375 and .450 inch standard ceramic bushings; two each .375 and .450 inch extra long ceramic bushings; necessary nuts, washers, and installation instructions.
Part No. 34604 34606 34610 34616 Watts 5,000 5,000 3,500 2,500 Voltage 480 277 480 240 Price 44.24 62.24 53.46 41.44
Provides reliable back up protection for temperature controlling thermostats and other over temperature conditions One time operation Three configurations available to accommodate in line or face plate mounting Rated for continuous operating currents of up to: 15 amps @ 120 VAC (Series 1) 25 amps @ 120 VAC (Series 2) Used with the Supco DH series duct heaters.
Temperature Part No. STC4257 STC4283 STC4333 STC5257 STC5333 STC6257 Limit (F) 262 291 333 262 333 262 Description In Line In Line In Line Face Plate Straight Face Plate Straight Face Plate Right Angle Series 1 1 1 1 1 1 Price 1.54 1.54 1.54 6.06 6.06 6.06
Nichrome heavy gauge construction. Welded terminal bolts for low resistance and longer life.
CRANKCASE HEATER
SELF-REGULATING HEATER
Contains close wound coil to fit many applications, two male and two female bushings, terminal screws, nuts, washers to make a proper repair and the SUPCO STC in line series thermal cutoffs.
Part No. DH500FC DH500 Watts 5,000 5,000 Voltage 240 240 Length (In.) 12 18 Price 25.00 17.84
34702
FUSIBLE LINK
Solid state crankcase heaters are PTCR self-regulating devices which perform in a similar manner to a heater and thermostat combination, in that they emit heat in proportion to the compressor requirements. Only enough electricity is consumed to maintain the correct temperature.
Part No. 32342 Description Heater w/Self Stick Foil Watts 36 Voltage 120/240 Price 126.4
Copeland replacement
CONTROLS & ELECTRICAL ACCESSORIES
Temperature Part No. 34702 34706 34708 34710 34712 Limit (F) 283 300 300 227 300 Description Fuse Link Only Fuse Link Only Round Ceramic Base Oblong Ceramic Base Oblong Ceramic Base Price 2.52 2.26 7.60 7.60 7.60 Part No. 32408 32409 32410 Length (In.) 4.25 4.25 4.25 Watts 100 100 100 Voltage 480 240 120 Application Model 4R, 6R, 6T, 4D, 6D 4R, 6R, 6T, 4D, 6D 4R, 6R, 6T, 4D, 6D Price 92.10 85.76 85.76 32409
1100
Copeland replacement
For commercial refrigeration applications to prevent moisture and eliminate frost build-up on door and cabinet fronts
Htg. Length Lead Length (Ft.) 6 6 Price 35.70 27.24
Length Part No. 32432 (In.) 3.5 Watts 200 Voltage 240
Application Model 6RJ, 4RJ, 4RR Price 80.26 Part No. SH281 GH282 Watts/Ft. 3 3 Voltage 120 120
(Ft.) 36 1/2 18
BAR, BOLT ON
Copeland replacement
Used with existing heater or where no heater exists Designed for series wiring connection only.
Length Part No. 32439 (In.) 5 Watts 50 Voltage 120 Application Model K, H Price 152.74 Part No. SH250 Lead Length (In.) 56 Voltage (Vac) 115 Watts 3 Diameter (In.) 0.91 Price 30.14
Application Model Price Part No. Length (In.) 9 13 13 21 21 E, 9R, 3A, 3R, LA, MR, NR 155.14 SH500 SH502 SH503 SH504 SH505
Durable Metal Braid Heater tip 7/16" diameter Silicone construction Designed for waterproof low wattage heat
Lead Length (In.) 18 18 18 18 18 Voltage (Vac) 115 115 230 115 230
Carlyle replacement
Watts 11 15 15 25 25
CONDENSATE PAN
Length Part No. 32462 (In.) 2.75 Watts 75 Voltage 230 Application Model 6D, 06D Price 225.60
DEFROST HEATER
BRAIDED HEATER
State-of-the-art, solid state, PTC control Self-regulating, conserves power, eliminates thermostat Removable cord set for ease of cleaning and installation Dimensions: 12 1/4 L x 4 3/4 W x 3 H
Part No. N070 Voltage (Vac) Watts Capacity (Oz.) 115 300 50 Evaporation Rate (Oz./Hr.) 6 Price 164.66
Flexible braided aluminum heaters are designed for use in heating drain troughs, drain tubes and drain pans.
SH202 Lead Length Part No. SH201 SH202 SH203 (In.) 18 29 44 Length (In.) 23 23 23 Voltage (Vac) 115 115 115 Watts 15 45 55 Price 21.86 27.84 28.00
1101
Standard cast aluminum condensate drains complete with long life heating element and mounting legs.
30OS Voltage Part No. 30OS N031 N075 75220 (Vac) 120 120 120 240 Watts 160 160 320 320 Capacity (Oz.) 38 50 75 75 Evaporation Rate (Oz./Hr.) 8 6 14 14 L 10 10 10 10 Size (In.) W 4 4 1/2 9 9 H 2 7/8 3 3/8 2 3/4 2 3/4 Price 68.34 109.06 260.20 286.20
For condensate applications where no drain is available Corrosion resistant stainless steel construction High limit safety and float switch operation UL, NSF approved
Voltage Part No. CP801 CP802 CP804 CP804 240 CP816 CP817 CP818 CP819 CP820 CP804HD CP807 CP807 240 CP815 CP815 240 CP821 (Vac) 120 120 120 240 120 208 208 120 208 120 120 240 120 240 208 Watts 400 800 1000 1000 500 1000 1000 1500 1500 1000 1000 1000 1440 1440 1500 Capacity (Oz.) 56 80 144 144 224 224 224 224 224 240 240 240 480 480 224 Evaporation Rate (Oz/Hr) 16 32 53.3 32 24 42.7 42.7 64 64 32 53.3 53.3 64 64 64 L 10 13 13 13 13 13 13 13 13 13 13 13 21 21 21 Dimensions (In.) W 7 7 7 7 10 10 10 10 10 10 10 10 13 13 13 H 2 1/2 2 1/2 4 4 4 4 4 4 4 4 4 4 4 4 4 Price 219.46 226.66 235.24 248.30 250.16 269.16 269.16 250.16 269.16 254.00 245.50 259.14 327.46 354.66 354.66
CPFLOAT Part No. CPH801 CPH802 CPH8047 CPH804 240 CPH804HD CPH807 240 CPH815 CPH815 240 CPH816 Description 400W Heater 800W Heater 1000W Heater 1000W Heater 1000W Heater 1000W Heater 1500W Heater 1500W Heater 500W Heater
CPH802 Usage CP801 CP802 CP804 CP804-240 CP804HD CP807-240 CP815 CP815-240 CP816 Price 37.80 38.04 43.06 49.06 77.00 46.36 77.00 77.00 77.00 Part No. CPH817 CPH818 CPH819 CPH820 CPH821 CPFLOAT CPFLOAT4 CPS800 CPT800 Description 1000W Heater 1000W Heater 1500W Heater 1500W Heater 1500W Heater 3 Float 4.5 Float Microswitch Thermostat Usage CP817 CP818 CP819 CP820 CP821 CP801, CP802 CP804, CP807, CP815 All All Price 77.00 46.04 77.00 77.00 77.00 40.26 49.04 38.40 30.80
1102
Identifies open controls in seconds. A single use monitoring device for determining which, if any, safety control has opened in response to a TT120 malfunction. When a control opens, the Tattle-tale's red indicator flag pops up. CAUTION Tolerance on all voltages: 20% Not to be used with lockout relays.
Part No. TT24 TT120 TT240 Voltage 24 120 240 Price 7.40 7.40 7.40
7714 Part No. 83336 7714 Description 30 Amps, 240V, 3-Pole Exterior Switch 60 Amps, 240V, 3-Pole Exterior Switch NEMA Case 3R 3R Price 155.08 220.86
Price 796.32
FLEXIBLE CONDUIT
PULLOUT TUBING
12SEALTITE Roll Length Part No. 12SEALTITE 34SEALTITE 1SEALTITE Description Flexible Conduit, 1/2" Flexible Conduit, 3/4" Flexible Conduit, 1" (Ft.) 100 100 100 Price/Ft. 2.08 2.50 1.54
Offers both fusible and non-fusible single phase air conditioner disconnects. These units provide a disconnecting means which should be 7711 located within sight to and readily accessible from air conditioning or refrigerating equipment. UL Listed.
Part No. 7711 7712 7713 Description 60 Amps, Non Fused, 1 60 Amps, Fused, 1 30 Amps, Fused, 1 Price 24.68 27.52 27.52
FITTING
NONMETALLIC
These horse power rated units are constructed of Noryl thermoplastic for extended and rugged durability. Units are corrosion resistant, weatherproof, and maintenance free. UL Listed and CSA Certified.
37.96 37.96
NON-FUSED
OUTSIDE DISCONNECT
HEAT PUMP
Multiple disconnect devices are offered for heat pump applications that require individual disconnects for the heating and cooling cycles. Units require four fuses.
Part No. 83325 Description 100 Amps, Fused Price 232.56
60 amp switch rated for 10 HP motors at 240 VAC. On-Off circuit breaker type switch. No pull-out head that can be lost or stolen. Four, one-inch combination knockouts two in back and two in bottom end wall. Removing the cover housing provides open access to lugs for easy wiring. Metallic - rain proof and ice proof (indoor/outdoor)
Part No. Q0200TR Description Molded Case AC Disconnect Switch, 60 Amps, 2-Wire, 240V, 2-Pole, Non-Fused Price 41.72
3.90
Part No.
Price
1103
Class RK5 250 Vac maximum, 125 Vdc Interrupting rating200,000A RMS FRNR30 symmetrical 10 seconds delay (minimum) at 500% rated current Blade connections 70 amps and larger
Part No. FRNR3 2/10 FRNR5 FRNR6 FRNR8 FRNR10 FRNR15 FRNR20 FRNR25 FRNR30 FRNR35 FRNR40 FRNR45 FRNR50 FRNR60 FRNR70 FRNR80 FRNR90 FRNR100 FRNR110 FRNR125 FRNR150 FRNR200 Amps 3 2/10 5 6 8 10 15 20 25 30 35 40 45 50 60 70 80 90 100 110 125 150 200 Price 12.00 11.48 12.00 12.00 11.48 9.20 9.20 9.20 9.20 16.82 16.82 16.82 16.82 16.82 37.84 37.84 39.68 37.84 94.20 83.16 83.16 83.16
SC10
Class G 480 Vac maximum, 300 Vdc (25 to 60A) Interrupting rating100,000A RMS symmetrical Diameter.41"
Amps 1 2 3 4 5 6 10 15 20 25 30 40 45 50 Length (In.) 1.319 1.319 1.319 1.319 1.319 1.319 1.319 1.319 1.419 1.639 1.639 2.259 2.259 2.259 Price 11.28 11.28 11.28 11.10 10.56 10.56 10.56 7.78 8.20 18.68 14.54 16.14 18.26 18.26
Part No. SC 1 SC 2 SC 3 SC 4 SC 5 SC 6 SC10 SC15 SC20 SC25 SC30 SC40 SC45 SC50
Class RK5 600 Vac maximum, 300 Vdc Interrupting rating200,000A RMS FRSR30 symmetrical 10 seconds delay (minimum) at 500% rated current Blade connections 70 amps and larger
Part No. FRSR2 FRSR5 FRSR10 FRSR15 FRSR20 FRSR25 FRSR30 FRSR35 FRSR40 FRSR45 FRSR50 FRSR60 FRSR70 FRSR80 FRSR90 Amps 2 5 10 15 20 25 30 35 40 45 50 60 70 80 90 Price 24.88 23.12 23.12 20.42 20.42 20.42 20.42 35.02 35.02 35.02 35.02 35.02 72.36 72.36 72.36
KTK5
Supplementary fuse Dimension13/32" diameter x 1 1/2" length 600 Vac maximum Interrupting rating100,000A RMS symmetrical
Amps 2 3 4 5 6 10 15 20 Price 20.48 20.48 20.86 20.48 19.92 20.48 20.48 20.56
Part No. KTK2 KTK3 KTK4 KTK5 KTK6 KTK10 KTK15 KTK20
1104
Class CCRejection type Dimension13/32" diameter x 1 1/2" length 600 Vac maximum Interrupting rating200,000A Branch circuit
Part No. KTKR10 KTKR15 Amps 10 15 Price 22.24 22.24
Rejection-type fuse Dimension13/32" diameter x 1 1/2" length 600 Vac maximum Interrupting rating200,000A RMS symmetrical
Part No. FNQR5 FNQR7 FNQR15 FNQR20 Amps 5 7 15 20 Price 27.22 31.80 27.06 28.00
Supplementary fuse Dimension13/32" diameter x 1 1/2" length FNM10 250 Vac (110 amps) maximum 32 Vac (2030 amps) maximum Interrupting rating10,000A @ 125 Vac
Part No. FNM2 FNM7 FNM10 FNM20 FNM25 FNM30 Amps 2 7 10 20 25 30 Price 8.52 9.04 8.52 8.90 10.10 8.90
Dimension 1/4" diameter x 1 1/4" length 250 Vac maximum to 10 amps 32 Vac maximum to 30 amps
AGC1
Interrupt Rating Part No. AGC1/2 AGC1 AGC1 1/2 AGC2 AGC3 AGC4 AGC5 AGC6 AGC8 AGC10 AGC15 Amps 1/2 1 1 1/2 2 3 4 5 6 8 10 15 20 25 30 Amps 35 35 100 100 100 200 200 200 200 200 1,000 1,000 1,000 1,000 Price 0.76 0.76 0.76 0.76 0.98 1.18 1.18 0.98 0.98 0.96 0.96 0.96 0.96 1.22
Supplementary fuse Dimension13/32" diameter x 1 1/2" length 500 Vac maximum Interrupting rating10,000A
Part No. FNQ5 FNQ10 FNQ15 FNQ20 Amps 5 10 15 20 Price 24.50 24.50 24.50 24.50
1105
FUSE, IN LINE
CERAMIC, TIME DELAY , GMQ
Size rejecting 300 Vac maximum Interrupt rating10,000A Use fuse holder HLQ3210
Part No. ABC1 ABC2 ABC3 ABC5 ABC8 ABC10 ABC12 ABC15
Amps 1 2 3 5 8 10 12 15
Interrupt Rating Amps 35 100 100 200 200 200 750 750
Part No. Price 1.86 1.86 1.86 1.82 1.82 1.82 1.82 1.82 GMQ3210
Amps 3 2/10
Price 16.86
FUSE, ACCESSORIES
PLUG FUSE BOX COVER
SSU
Single fuse Switch control Installs easily in standard electrical box 125 Vac, 15A
Type Box 2 1/4" Handy 4" Square Price 50.84 86.30
Amps 5 10 20
Furnished with 3 springs for different length fuses 8" leads 1/4" diameter, 7/8" to 1 1/4" length fuse
Part No. HRK Description Fuse Holder Price 8.58
32 Vac maximum
ATC4 Color Code Gray Violet Pink Tan Blue Yellow Green
FUSE PULLER
Amps 2 3 4 5 15 20 30 Price 1.30 0.94 0.94 0.94 0.94 0.94 0.94
Part No.
FP2 Application Part No. FP2 FP3 FP6 Diameter Fuse (In.) 13/32 to 13/16 1 to 1 3/4 0 to 60A T-Tron Fuse Price 45.62 58.16 86.34
Amps 8 15
1106
Package N0028 Package Part No. N0028 N0331 Description Bushing, Screw-On Washer Anti-Short Bushing, 14/2, 14/3, 12/2, 5/16 Qty. 5 35 Price 11.90 4.78 Part No. N1318 Description Duplex Connector, Clamp Type, 1/2" Knockouts, 3/8" Trade Qty. 2 Price 7.80
BUSHING, CONDUIT
REDUCING WASHER
N1301 Package Part No. N1301 Package Part No. N0310 Description Reducing Washer, 3/4"1/2" Qty. 28 Price 8.40 N1303 Description 1/2 Offset Conduit Bushing 1/2 Straight Conduit Bushing Qty. 2 2 Price 12.30 9.20
CONNECTOR, ROMEX
CONDUIT STRAP
N1306 Size Part No. N1306 N1307 N1304 N1305 (In.) 1/2 3/4 1 1 1/4 Package Qty. 20 12 8 6 Price 5.90 5.00 5.70 7.20 Part No. N1320 Description Romex Connector, Clamp Type,1/2" Knockouts, 3/8" Trade
PLUG ADAPTER
PLUG
CONNECTOR, BX
N2867 Package Package Part No. N1311 Description BX Connector, 1/2" Knockouts, 3/8" Trade Qty. 25 Price 24.50 Part No. N2867 N2887 Description Armored Plug, Male, 2 Pole, 3 Wire 15A125V Armored Connector, Female, 2 Pole, 3 Wire, 15A-125V Qty. 1 1 Price 8.60 14.40
CONNECTOR, 90 PIGTAIL
UL/CSA Listed 16/3 AWG PT6S is straight out, PT6 is top out
Package Part No. N1315 Description 90 Connector, Steel Cover, 1/2" Knockouts, 3/8" Trade Qty. 3 Price 8.30 PT6 Part No. PT6 PT6S Length (Ft.) 6 6 Weight (Lbs.) 1.00 1.00 Price 9.90 9.56
1107
PATCH CORD
Description Duplex Receptacle, 2 Pole, 3 Wire,15A-125V Duplex Receptacle, 2 Pole, 3 Wire, 20A-125V Single Receptacle, 2 Pole, 3 Wire, 20A-250V
WALL SWITCH
Description Wall Toggle Duplex Cover Square Cover/Duplex Receptable Square Cover, Blank Single Wall Toggle Utility Cover
Description On-Off, 15A, 120V Silent, 1 Pole, 20A-120/277 Vac Silent, 2 Pole, 15A-120/277 Vac
TOGGLE SWITCH
Price 7.90
Package Qty 1 1 1 1
1108
Compressor applications
N6270L Part No. N0384 Description Weatherproof Box w/Switch and Cover Price 28.30 Part No. N6271 N6258C N6270L Wire Size (AWG) 18-16 16-14 12-8 Tab Size (In.) .090 Pin .250 .250 Package Qty. 17 100 50 Price 4.80 33.00 24.70
Description
Price N6224C Wire Size Part No. N6213C N6277N N6224C (AWG) 16-14 16-14 12-10 Tab Size (In.) .250 .250 .250 Insulated No Yes No Package Qty. 100 25 100 Price 28.00 17.10 26.70
SOLDERLESS TERMINAL
BUTT CONNECTOR, INSULATED
N6229L Wire Size (AWG) 16-14 16-14 16-14 Tab Size (In.) .250 .250 .250 Gender F F M Package Qty. 50 50 50 Price 20.20 20.90 18.70
1109
Part No. Wire Size Part No. N6219 (AWG) 16-14 Tab Size (In.) .250 Package Qty. 24 Price 6.90 N6238L N6239L N6276L
Stud Size 8 8 8
Insulated
N6210 N6285L Wire Size Part No. N6285L N6286L (AWG) 16-14 16-14 Tab Size (In.) Plug/.157 Receptacle/.157 Package Qty. 50 50 Price 17.50 16.30 Part No. N6210 N6211C N6212 Qty. Gender 1 M/1 F 2 M/1 F 2 M/1 F Tab Size (In.) .250 .250 .250 Package Qty. 24 100 24 Price 8.00 20.50 7.70
INSULATED RING
TERMINAL KIT
N6236L Wire Size Part No. N6236L N6272L N6216L N6252L N6253L N6257N (AWG) 22-18 16-14 16-14 12-10 12-10 8 Stud Size 8 8 10 10 1/4" 1/4" Package Qty. 50 50 50 50 50 25 Price 10.80 11.20 11.90 17.30 18.00 18.30
N6200A
N6200A16-14 wire range; stud sizes 8 and 10 N6200D12-10 wire range; stud size 10 In plastic container
Description (Qty.) Includes N6211 (15), N6213 (20), N6217 (10), N6218 (15), N6227 (10) Includes N6211 (10), N6224 (10), N6231 (10), N6251 (10), N6252 (10), N6255 (15)
TERMINAL REPAIR
TLC310 N6237L Wire Size Part No. N6237L N6274L N6227L N6228L N6255L (AWG) 22-18 16-14 16-14 16-14 12-10 Stud Size 8 6 8 10 10 Package Qty. 50 50 50 50 50 Price 10.90 11.40 11.40 11.40 15.90 Part No. TLC310 TLC312 Description 10 Gauge Compressor Stake Kit 12 Gauge Compressor Stake Kit Price 57.76 52.50
MAGJUMPER
Ideal for recessed terminals, and low voltage troubleshooting No more popping off terminals Great for troubleshooting thermostats, control boards, sensors and switches Stays flexible in cold weather
Part No. MJ1 Description MagJumper 20" Leads, 1/4" Yellow Tip Price 23.16
1110
QwikLug easily attaches to damaged or corroded spade connectors. Simply push the connector on and tighten it QT2810 from the front with a Phillips screwdriver. QwikLug comes with color coded leads for connecting to existing wiring. The outer connector housing is a nylon insulator so the connectors can touch without shorting.
Part No. QT2810 QT2812 QT2910 Description Terminal Lugs, 30 Amps, 10 AWG / 2 ft. Leads with Nut, Pkg of 3 Price 49.00
Part No. 32145012 32141012 32265012 32261012 32155012 32151012 32765012 32761012 32165012 32161012 32175012 32171012
Terminal Lugs, 20 Amps, 12 AWG / 2 ft. Leads with Spade, 47.34 Pkg of 3 Terminal lugs, 30 Amps, 10 AWG / 4 ft. Leads with Nut, Pkg of 3 57.66
WIRE
18 GAUGE
No. Conductors Length Reel (Ft.) 2 500 2 1000 3 500 3 1000 4 500 4 500 5 500 5 1000 6 500 6 1000 8 500 8 1000
Wt. (Lbs.) 9.98 19.96 13.12 26.24 13.36 32.72 19.37 38.63 22.72 45.45 29.19 58.38
Price 218.30 436.60 293.30 586.56 346.22 692.44 430.96 820.34 493.26 948.28 602.06 1204.12
UL Listed type CL2 CUL Listed type CM or CHM/FT1 NEC article 725
UL1882 No. of Length Conductors Comment Reel (Ft.) 2 500 2 Shielded 500 3 500 3 Shielded 500 4 250 4 Shielded 250 5 250 5 Shielded 250 6 250 7 250 8 250 8 Shielded 250 9 250 10 250 12 250 Part No. Wt. (Lbs.) 7.00 10.00 9.50 13.00 6.25 8.25 7.75 19.25 9.25 11.00 12.50 28.00 13.75 15.25 16.25 Price 113.02 183.72 171.84 258.74 116.52 155.70 119.42 215.02 166.30 181.36 179.60 270.16 245.08 254.04 325.66 32531102 Wire Size 22
No. of Pairs 2
Price 653.70
Part No. UL1825 UL1825S UL1835 UL1835S UL184250 UL1842S UL1852 UL1852S UL1862 UL1872 UL1882 UL1882S UL1892 UL18102 UL18122
HOOK-UP WIRE
UL Listed type CMP/MPP/CL2P CUL Listed type CMP/FT6 NEC article 725 and 800
PLN5508 Part No. PLN5502 PLN5503 PLN5504 PLN5505 PLN5506 PLN5508 PLN5510 No. Conductors Length Reel (Ft.) 2 500 3 500 4 250 5 250 6 250 8 250 10 250 Wt. (Lbs.) 10.25 11.00 7.25 8.75 10.50 11.25 15.25 Price 170.24 220.36 152.10 186.00 222.92 267.44 356.12
THERMOSTAT WIRE
N6336 Part No. N6336 N6337 Wire Size/Conductors 18 3 18 5 Package Length (Ft.) 40 40 Price 26.30 43.60
1111
1112
1113
N6293C
WIRE NUT
STRANDED-SHIELDED
Color-coded connector shells are made from high dielectric, smooth polypropylene plastic to eliminate porosity and surface cracking. Resists practically all chemical action unaffected by gasolines, oils, diluted acids and alkaline solutions. Heat-resistant up to 105C (221F).
Color Part No. N6291C N6292C N6293C N6294C N6296C N6295 Code Grey Blue Orange Yellow Red Size Mini Mini Small Medium Large Description Assortment: Yellow (15), Orange (15), Grey (15), Red (10) 12.00 Package Qty. 100 100 100 100 100 Price 12.30 13.70 15.50 21.40 27.00
STRANDED WIRE
MSW stranded (non-shielded) cable used for mini-split installation THHN, 600 volt
Part No. MSW14450 MSW144250 No. of Conductors 4 4 Gauge 14 14 Length (Ft.) 50 250 Price 111.26 556.28
TERMINAL BLOCK
WIRE MANAGEMENT
WIRE CONNECTOR
N6183 Part No. N6183 N6185 N6187 N6193 N1327 N6195 Description Split Bolt Connector, #8 Wire Split Bolt Connector, #6 Wire Package Qty. 3 3 Price 16.78 22.90 Description 6 Position, 20A, 250V, 14 AWG Maximum 10 Position, 20A, 250V, 14 AWG Maximum 14 Position, 20A, 250V, 14 AWG Maximum 6 Position, 30A, 600V, 12 AWG Maximum 10 Position, 30A, 600V, 12 AWG Maximum Price 5.54 8.90 12.76 10.18 16.08
CABLE MARKER
WHIP
Nonmetallic sealtite
N1002
Made of vinyl impregnated cloth and mounted on dispenser cards in a portable book. All markers are designed for both above and below ground applications.
N63124 Part No. Length Part No. N63124 N63126 N63344 N63346 (Ft.) 4 6 4 6 Connector (In.) 1/2 1/2 3/4 3/4 Wire Size #10 #10 #8 #8 Price 25.90 31.50 34.60 37.60 N1002 N1003 Description A-Z and 0-15 #1 to #45 Price 32.10 32.10
1114
N6262BC Length Part No. N6262BC N6262BM N6263BC N6263BD N6265BC (In.) 7 7 11 11 14 Maximum Diameter (In.) 1 3/4 1 3/4 3 3 4 Package Qty. 100 1,000 100 500 100 Price 7.66 70.74 9.96 49.28 17.46
N5381 Part No. N5381 N5382 N5383 N5384 N5385 Pipe OD (In.) 1/8 1/4 3/8 1/2 5/8 Package Qty. 54 45 41 39 37 Price 5.38 6.22 6.22 6.22 6.22
Assorted 6" lengths Includes 2 pieces each of: 1/8" Black , 1/8" White 1/4" Black, 1/4" White 1/2" Black, 1/2" White
Package Qty. 50 50 1,000 500 50 Price 3.36 3.54 58.34 64.76 7.14 Part No. N6370 Description Heat Shrink Tube Assortment Price 17.50
(In.) 5 7 7 11 11
TEST LEAD
JUMPER
N5031 Part No. N5031 Length Part No. N6264N (In.) 7 Maximum Diameter (In.) 1 3/4 Package Qty. 25 Price 3.74 N6025 N5032 Description 8 Leads, Color Coded, Alligator Clip (Sm.) 2 Leads, 18" Wire, Alligator Clip (Med.) Compressor Lead Kit Pkg. Qty. 8 2 3 Price 14.70 14.50 19.70
Package Qty. 50
Price 21.98
Pkg. Qty. 2
Price 31.32
ALLIGATOR CLIP
N5035 Part No. N5035 N5036 Description Alligator Clip (Med.), 2", 4 Ea. Test Clip (Lg.), 2 1/2", 2 Ea. Pkg. Qty. 4 2 Price 7.00 9.50
1115
EZ HOOK
1116