Maximum Load On A Pile/Pile Capacity (kN) P Total Gravity Load (kN) DP Diameter Of Pile (m) Lcx Length Of Col./Pedestal Along X Dir (m) Length Of Col./Pedestal Along Z Dir (m) Yield Stress Of Steel (N/mm ) Yield Stress Of Concrete (N/mm ) Load Factor ASSUMED DATA: Dia Of Bar Along X-Direction(mm) Dia Of Bar Along Z-Direction(mm) Dia Of Secondary Bars (mm) Depth Of Slab(mm) Pile Spacing Along X Direction (m) Pile Spacing Along Z Direction (m) Projection Of Slab Beyond Piles (m) DERIVED DATA: Cantilever Projection Along X Direction (m) Cantilever Projection Along Z Direction (m) Effective Depth In X Direction (mm) Effective Depth In Z Direction (mm) Length Of Slab Along X Direction (m) Length Of Slab Along Z Direction (m)
2 2
20 1.5
x z sec
x
O
12 12 10 700 1.1 1.1 0.15 0.2 0.2 644 632 1.7 1.7 113.1428571 113.1428571
Factored moment (kN-m) Effcctive Depth Required (mm) Provide Overall Depth (mm) Check For Depth Effective Depth Provided (mm) Area Of Steel: A B C Area Of Steel(Ast) (mm2) Nos Of X Bar Required Nos Of X Bar Provided AstCD Provided (mm2) Spacing (mm) Spacing Provided (mm) Percentage Steel Provided
340.5 269.3888128 (OK/NOT OK) OK 644 0.87*fy2/(fck*bz) .87fy*d M*10^6 4.406933824 232516.2 340500000 1507.485556 13.32373598 14 1584 121.4285714 121 0.144683961
Along Z Direction
Factored moment (kN-m) Effcctive Depth Required (mm) Provide Overall Depth (mm) Effective Depth Provided (mm) Area Of Steel: A B C Area Of Steel(Ast) (mm2) Nos Of X Bar Required Nos Of X Bar Provided AstCD Provided (mm2) Spacing (mm) Spacing Provided (mm) CHECK FOR SHEAR:
One Way Shear Check:
Section For Diagonal tension is tested at a distance 0.5d from the face of the pedestal ie at section AA Distance Between Pile & Column/Pedestal Faces (mm) Along X Direction X Y Z Shear Force By Linear Interpolation (kN) Nominal Shear Stressv (N/mm ) Shear strength of Concrete For Above % Of Steel (n/mm2) pt fck Beta c(N/mm2) Whether Ok For One Way Shear
Two way Shear Check
2
Vu
The Critical Section Lies 0.5d Around The Pedestal Of The Column Shear Force Nominal Shear Stressv (N/mm2) Shear Strength Of Concrete Whether OK For Two Way Shear CHECK FOR DEVELOPMENT LENGTH : Vo (kN) v (N/mm2) c (N/mm2) 1200 0.346606034 1.118033989 OK
Bond Stress
bd (N/mm2)
Ld
SIGN OF PILE CAP ( For Four Piles Only) onsidering Full Pile Capacity For Design)