Vous êtes sur la page 1sur 9

Laboratory Water Purification Systems WATER-PURIFICATION

WPL Series, Laboratory Water Purification Systems WPL-RO series deionized water system (Tap water inlet) WPL-RO-S series ultra pure water system(Tap water inlet) WPL-RO-D series ultra pure water system (DI water inlet).
Features and Advantage:
Control System Microprocessor control Display System 240x128 Graphical LCD display Quality Monitor quality of inlet, RO outlet and ultrapure Visual and Audio Alarm Recirculation System Safety System Filter replasement remainder
3-way online sensor, detecting the water respectively Multiple alarm-including inlet water over standard, no water, full water, outlet water over standard, Consumables life-span ends, malfunction auto-detect Manual and auto, freely switchable, ultrapure water recirculation system, keeping a low polluted-level of bacteria With factory and clients two password, every system setting can be protected, avoiding unauthorized operating The life-span can be set and the time used and left can be displayed, replacing auto-reminding, avoiding the decline of water quality. Ultra pure water pipeline can be regularly disinfected to keep a high quality water

Sanitization system RO membrane Automatically RO membrane flushing function, extending its life-span flush on-off duty On/off duty mode increase filter life span mode

LCD display function:

Water tank Machine case Pipeline and adaptor

Various kind of tanks to meet different needs and assure water-supply Human engineering design, streamline case

Pipeline with NSF authorization to assure high quality ultrapure water; new easyinserting adaptor to make convenience of cartridge maintaining and replacing Ultra long-life pre-cartridge, 6-8 times of Pretreatment normal active carbon (expect PP filter), unnecessary replacement for 2 year most, cartridge reducing the working cost Manufactured by DOW or FCS, realize the RO membrane combination of long-life and high-quality Ultra purification 4 cartridges of ultra purification, using famous nuclear resin to assure best quality cartridge

UV module UF module Terminal Filtration

Double wavelength (185nm & 254nm) UV lamp, restraining bacterias increase, reducing TOC & enhancing the applicability MWCO 5000D PES UF module, effectively eliminating endotoxin, can be used for precise cell cultivating and IVF Sartorius high-speed and large flux 0.45+0.2 m polyether alternative compound filter terminal disinfection filter, assuring the quality absolutely axenic

Water flow chart: WBL

WATER-PURIFICATION
Accessories:

Extra pretreatment

Including: microfiltration, soft water, KDF filter cartridge, dislodge granular, residual chlorine, organics, heavy metal in case of scaling, bacterial growth & hard warter.

The capacity is 12 liter, ensure the resisitivity is more than 10M-cm, and it could produce about 20000 liter water.

Built-in polishing resin cartridge

Built-in tank

Remote water gun


You could take the water from 3 meters away, if has the water gun.

It has 2 pieces of 15 liter tank, and save more room.

Humanized tray

Its a good place for water cup.

Portable resistivity meter


Measure the resistivity easily in any place.

Utilizing global high-quality parts: RO membrane: DOW or CSM Ultra purification cartridge: Rohm&hass or DOW UV,UF cartridge: world famous brand Terminal filtration: world famous brand Pump: world famous brand Water quality monitor system: world famous brand Other components: mp world famous brand. Options:
Model 171-1-000010 171-1-000011 171-1-000012 171-1-000013 171-1-000014 171-1-000015 171-1-000016

Incorporating cutting-edge technology: RO series uses the reverse osmosis technology of NASA. Desalination rate99%, eliminating virus rate99.5% Special circle-inside function to guarantee water quality II mixed beds guarantees water quality and increase the life-span of ultra purification cartridge Double wave length UV lamp efficiently decreases virus and TOC Ultra purification cartridge efficiently eliminates endotoxin High flux terminal filtration with pre-filtration function.
Description
Bottom layer

10 pretreatment filter, Including 10 spun fiber filter, water softner, KDF Pure polishing resin cartridge, Capacity is 12 liter Tank, Capacity is 15 liter Water gun, Including PFA telescopic pipe 1/4 3M Water gun, Including PP telescopic pipe 1/4 3M Portable resistivity meter

Pure water systems WATER-PURIFICATION


WPL-RO-HP-15/30 Systems, Deionized Pure Water Systems (Tap water inlet)
Model Flow procedure Reverse osmosis deionized water purification system WPL-RO-15 WPL-RO-HP-15 WPL-RO-30 WPL-RO-HP-30
PF+KDF+AC+RO PF+KDF+AC+RO+ PF+KDF+AC+RO PF+KDF+AC+RO+ +AC-DI AC+UV+DI+TF +AC+DI AC+UV+DI+TF ware washing Agricultural expe General biological expe Aquatic products feeding Inlet water for Ultra pure water machine Inler water for sterilizer/ T&H chamber Buffer disposing Aseptic drinking water Physical and chemical analysis Fine chemistry industry Inlet water for Ultra pure water machine GC/HPLC High pure water resistivity:17.5-13 M-cm, RO water(TDS):10-5ppm*, Heavy metal<0.1ppb, TOC<30ppb. Bacteria <1 CFU/ml(Only for UT model), Particle(>0.22m)<1/ml(Only for UT model) 15 Liters/hour* / 30 Liters/hour* 1.5 Liters/hour (with pressure tank) RO Water, High pure water WDH:543650cm/ 30-20 Kg/ 220V/50HZ, 120W Power on, program, inlet rinse, producing, full, circle, regular outlet, disinfection, consumables replacing reminder Low pressure and full water alarm, password,auto-reset, outlet forbidden if alarm or disinfection Monitoring quality of inlet water, RO water and ultrapure water, temperature, used and left time of consumables Tap water; inlet TDS<200 ppm, 1-40OC, 1.0-3.5 kg/cm2 (if inlet TDS>200ppm, pretreatment is recommended) 5m spun fiber filter+1 Long-effective KDF filter+1 Granular active carbon filter1 100 GPD RO membrane1 (30L model: 2100 GPD RO membrane) Post active carbon filter1 + Mixed resin cartridge3 {30L model: Mixed resin cartridge4} UT model: 254nm UV cartridge1 + 0.2m terminal filter1 Main body(including:1 set cartridge)+4gallon tank

Application Pure water Index Output(25OC) Moment output Technical spec. Pure water outlet Dimension / Weight / Power Mode display Control system Safety System monitor Water source required Pretreatment unit Purification system RO unit Subsequent unit Standard configuration

* ** ***

Inlet water: TDS200ppm, 25OC, 50psi and 15% recovery rate. GPD=gallon per day 1gallon=3.8L. The quality of inlet water will effect outputs and cartridges life. PF: Pretreating, KDF: Kinetic degradation fluxion, AC: Active carbon, RO: Reverse osmosis, DI: Ion exchange, UV: Ultraviolet, TF: Terminal filter.

WATER-PURIFICATION Ultra Pure water systems


WPL-RO-UP Systems, Ultra Pure Water Systems (Tap water inlet)
Standards Model Flow procedure Application Resistivity Heavy metal Pure water quality TOC Bacteria Endotoxin Particle(>0.22m) TDS (RO water) Output(25 C)
O

WPL-RO-UP-15-S WPL-RO-UP-30-S
PF+KDF+AC+RO +AC-DI+TF GC,HPLC,IC,ICP PCR,weather analyse Amino acid analyse Reagent preparation

Eliminating endotoxin WPL-RO-UP-15-UF WPL-RO-UP-30-UF


PF+KDF+AC+RO+ AC+DI+UF+TF

Low TOC WPL-RO-UP-15-UV WPL-RO-UP-30-UV


PF+KDF+AC+RO+ UV+AC+DI+TF

Comprehensive WPL-RO-UP-15-UVF WPL-RO-UP-30-UVF


PF+KDF+AC+RO+ UV+AC+DI+UF+TF

Molecular biology HPLC,IC,ICP-MS HPLC,IC,ICP-MS,CF-AAS Cell & tissue cultivation TOC & organism analyse Physics,electrochemistry, Life science,IVF CF-AAS,toxicology study Molecular biology, electrophoresis Environmental analyse Cell cultivation 18.2 M-cm@25OC < 0.1ppb

<10 ppb <1 CFU/ml <0.001 EU/ml <1 / ml 5-10 ppm* 15/30 Liters/hour* -

<3 ppb <0.001 EU/ml

Technical spec. Pure water outlet Dimension / Weight / Power Mode display Control system Safety System monitor Water source required Pretreatment unit Purificati on system RO unit Subsequent unit

Moment output

1.5 Liters/min (with pressure tank) (Less output with UF/UV cartridge) RO Water, Ultra pure water WDH: 5036 54cm / 20-30 Kg / 220V/50HZ, 120W Power on, program, inlet rinse, producing, full, circle, regular outlet, disinfection, consumables replacing reminder low pressure and full water alarm, password, auto-reset, outlet forbidden when alarm or disinfection status Monitoring quality of inlet water, RO water and ultrapure water, temperature, used and left time of consumables Tap water; inlet TDS<200 ppm, 1-40OC, 1.0-3.5 kg/cm2 (if inlet TDS>200ppm, pretreatment is recommended) 5m spun fiber filter1+ Long-effective KDF filter1+ Granular active carbon filter1 (30L model: 10 PP filter1+10 KDF filter1+10granular active carbon filter1) 100 GPD RO membrane1 (30L model: 2100 GPD RO membrane) Post active carbon filter1 +Ultra pure polishing resin cartridge 0.2 +4m terminal filter1 UV model:+Double wavelength(254&185 nm)UV cartridge1 UF model:+ 5000 Doulton UF cartridge1 UVF model:+Double wavelength(254&185 nm)UV cartridge5000+1 Doulton UF cartridge1 Main body(including:1 set cartridge)4+gallon tank

Standard configuration

* ** ***

Inlet water: TDS200ppm, 25OC, 50psi and 15% recovery rate. GPD=gallon per day 1gallon=3.8L. The quality of inlet water will effect outputs and cartridges life. PF: Pretreating, KDF: Kinetic degradation fluxion, AC: Active carbon, RO: Reverse osmosis, DI: Ion exchange, UV: Ultraviolet (Double wavelength: 254&185nm), UF: Ultrafiltration TF: Terminal filter.

Ultra Pure water systems WATER-PURIFICATION


WPL-UP Systems, Ultra Pure Water Systems (Pure water inlet)
Model Flow procedure Application Resistivity Heavy metal Pure water quality TOC Bacteria Endotoxin Particle(>0.22m) Output Technical Pure water outlet spec. Dimension / Weight / Power Mode display Control system Safety System monitor Water source required Purification system Standard configuration
<0.001 EU/ml <1 / ml 1.5 Liters/min(Less output with UF/UV cartridge) High pure, Ultra pure water WDH:543650cm/ 30-20 Kg/ 220V/50HZ, 120W Power on, program, inlet rinse, producing, full, circle, regular outlet, disinfection, consumables replacing reminder low pressure and full water alarm, password, auto-reset, outlet forbidden when alarm or disinfection Monitoring quality of inlet water, RO water and ultrapure water, temperature, used and left time of consumables Ro water, distilled water, deionized water.5-45OC,1atm* Post active carbon filter+1Mixed bed resin cartridge+1Ultra pure polishing resin cartridge +4 0.2m terminal filter1 UV model:+Double wavelength(254&185 nm)UV cartridge1 UF model:+ 5000 Doulton UF cartridge1 UVF model:+Double wavelength(254&185 nm)UV cartridge5000+1 Doulton UF cartridge1 Main body(including:1 set cartridge) <10 ppb <1 CFU/ml <0.001 EU/ml

Standards WPL-UP-S
AC+DI+TF GC,HPLC,IC,ICP PCR,weather analyse Amino acid analyse Reagent preparation

Eliminating endotoxin WPL-UP-UF


AC+DI+UF+TF

Low TOC WPL-UP-UV


UV+AC+DI+TF

Comprehensive WPL-UP-UVF
UV+AC+DI+UF+TF

Molecular biology HPLC,IC,ICP-MS HPLC,IC,ICP-MS,CF-AAS Cell & tissue cultivation TOC & organism analyse Physics,electrochemistry, Life science,IVF CF-AAS,toxicology study Molecular biology, electrophoresis Environmental analyse Cell cultivation

Ultra pure water:18.2 M-cm@25OC ;High pure water:3 M-cm < 0.1ppb <3 ppb

The quality of inlet water will effect outputs and cartridges life. AC: Active carbon, DI: Ion exchange, UV: Ultraviolet (Double wavelength: 254&185nm), UF: Ultrafiltration TF: Terminal filter.

Consumables & accessories of master series


Model 171-2-000030 171-2-000031 171-2-000032 171-2-000033 171-2-000034 171-2-000035 171-2-000036 171-2-000037 171-2-000038 171-2-000039 171-2-000040 171-2-000041 171-2-000042 171-2-000043 171-2-000044 171-2-000045 Specs
5m spun fiber filter Long-effective KDF filter Granular active carbon filter Post active carbon filter 10 PP filter 10 KDF filter 10granular active carbon filter 100 GPD RO membrane Mixed bed resin cartridge Ultra pure polishing resin cartridge 5000 Doulton UF cartridge 0.2m terminal filter 254nm UV cartridge 254 nm lamp Double wavelength (185&254nm)UV cartridge 185&254 nm UV lamp

Replacement term
About 2-6months About 1 year About 6months About 9000 liters water About 2-6months About 1 year About 6months About 1-2 years About 1000L water About 1000L water About 1 year About 9000 hours About 9000 hours

WATER-PURIFICATION Water systems


WPB Series, Water purification systems WPB-RO series reverse osmosis pure water system (Tap water inlet) WPB-RO-DI series deionized water system (Tap water inlet) WPB-Ultra series ultra pure water system (Tap water inlet) WPB-Research series ultra pure water system (DI water inlet).

RO-UP Digital System

RO-DI System

RO-DI Digital System RO System

Water flow chart: Ultra pure UVF

Water systems WATER-PURIFICATION


WPB-RO-(HP) Systems, Pure water systems (Tap water inlet)
Model Flow procedure WPB-RO-15 WPB-RO-30 WPB-RO-HP-15 (D)**** WPB-RO-HP-30 (D)****
PF+AC+RO+AC PF+AC+RO+AC PF+AC+RO+DI PF+AC+RO+DI ware washing Agricultural expe General Buffer disposing Aseptic drinking water biological expe Aquatic products feeding Physical & chemical analysis Fine chemistry Application Inlet water for Ultra pure water machine Inlet industry Inlet water for Ultra pure water water for sterilizer/T&H chamber machine GC/HPLC Pre-filter (optional)+Special spun fiber filter1+ Special active carbon block filter Pretreatment unit 1+Special active carbon block filter1 100GPD RO membrane 2100GPD RO membrane 100GPD RO membrane 2100GPD RO membrane Mixed bed resin Mixed bed resin Post active carbon filter1 Subsequent unit cartridge2 cartridge3

Purification system

RO unit

Pure water quality

Desalination rate%

96-98* 5-10 ppm -

Nearly 100* RO water: 5-10 ppm 15-18.2M-cm 0.055-0.067s/cm

TDS Resistivity Conductivity Pure water outlet Control system

RO Water RO Water, Deionized water Automatic electronic pressure sensor controlling, RO membrane auto flushing, automatic stop without water, automatic stop when water tank full, automatic cutting off water when pump stopping, guaranteeing 24 hours work. TDS test pen 15 liters/hour* 30 liters/hour* TDS test pen + LCD online resistivity monitor 15 liters/hour* 30 liters/hour* Tap water:TDS<200ppm,5-40OC,1.0-3.5Kg/cm2 1.5 L/min (with pressure tank) 220V/50Hz, 48W plus model:72W HWD:424122cm / 12-14kg Main body(including:1 set cartridge)+3.2gallon tank

Water quality monitor Inlet water requirement Output(25OC) Instantaneous output Power External dimension/Weight Standard configuration

* Inlet water: TDS200ppm, 25OC, 50psi and 15% recovery rate. ** GPD=gallon per day 1gallon=3.8L. *** The quality of inlet water will effect outputs & cartridges life. PF: Pretreating, AC: Active carbon, RO: Reverse osmosis, DI: Ion exchange. **** Digital display option

WPB-UP Systems, Ultra pure water systems (DI water inlet)


Model Specification Flow procedure

WPB-UP-S
Standard AC+DI+TF Microanalysis Environmental analysis AA,ICP,IC Buffer disposing Pharmacy research Medicine examining.

WPB-UP-UF
Eliminating endotoxin AC+DI+UF+TF Molecular biology PCR, gene research Pharmacy research Medicine examining, Cell cultivating, IVF etc.

WPB-UP-UV
Low TOC AC+DI+UV+TF Micro organic analysis Environmental analysis HPLC,TOC, VOC, GC/MS Pharmacy research Medicine examining.

WPB-UP-UVF
Comprehensive AC+UV+DI+UF+TF Molecular biology Micro organic analysis Environmental analysis Pharmacy research Medicine examining Cell cultivating IVF etc.

Application

Inlet water Purification system Resistivity Pure water quality Heavy metal TOC Endotoxin particle(>0.22m) Bacteria Pure water outlet

Ro water, distilled water, deionized water Post active carbon filter1+Mixed bed resin cartridge1+Ultra pure polishing resin cartridge 4+0.22m terminal filer1 UV model:+Double wavelength (185&254 nm) UV cartridge1 UF model:+ 5000 Doulton UF cartridge1 UVF model:+Double wavelength(185&254 nm) UV cartridge1+5000 Doulton UF cartridge1

18.2 M-cm @25OC <0.1ppb <10ppb < 0.001Eu/ml


<1/ml <1cfu/ml High pure, Ultra pure water Automatic electronic pressure sensor controlling, recirculation function; LCD online resistivity monitor. 1.0 - 1.3 liters/min (with pressure tank) (Less output with UF/UV cartridge) 220V/50Hz, 72W HWD:424122cm / 12-14kg Main body(including:1 set cartridge)

<5 ppb < 0.001Eu/ml

Control & display system Output(25OC) Power External dimension/Weight Standard configuration

* Inlet water: TDS200ppm, 25OC, 50psi and 15% recovery rate. ** GPD=gallon per day 1gallon=3.8L. *** The quality of inlet water will effect outputs and cartridges life. AC: Active carbon, DI: Ion exchange, UV:Ultraviolet(Double wavelength:254&185nm), UF:Ultrafiltration, TF:Terminal filter.

WATER-PURIFICATION Water systems


WPB-RO-UP Systems, Ultra pure water systems (Tap water inlet)
Model Specification Flow procedure

WPB-RO-UP-15-S WPB-RO-UP-30-S
Standard PF+AC+RO+DI+TF Microanalysis Environmental analysis AA,ICP,IC Buffer disposing Pharmacy research Medicine examining.

WPB-RO-UP-15-UF WPB-RO-UP-30-UF
Eliminating endotoxin PF+AC+RO+DI+UF+TF Molecular biology PCR, gene research Pharmacy research Medicine examining, Cell cultivating, IVF etc.

WPB-RO-UP-15-UV WPB-RO-UP-30-UV
Low TOC Micro organic analysis Environmental analysis HPLC,TOC, VOC, GC/MS Pharmacy research Medicine examining.

WPB-RO-UP-15-UVF WPB-RO-UP-30-UVF
Comprehensive Molecular biology Micro organic analysis Environmental analysis Pharmacy research Medicine examining Cell cultivating IVF etc.

PF+AC+RO+UV+DI+TF PF+AC+RO+UV+DI+UF+TF

Application

Pretreatment unit Purification system RO unit Subsequent unit Resistivity Heavy metal Pure water quality TOC Endotoxin particle(>0.22m) Bacteria Pure water outlet Control system Water quality monitor Inlet water requirement Output(25OC) Instantaneous output Power External dimension/Weight Standard configuration

Pre-filter (optional) Special spun fiber filter (30L model: outside 10 spun fiber filter)1+Special active carbon block filter1+Special active carbon block filter1 100GPD RO membrane1 (30L model: 2100GPD RO membrane) Ultra pure polishing resin cartridge 0.22+4m terminal filer1 UV model:+Double wavelength(254&185 nm)UV cartridge1 UF model:+ 5000 Doulton UF cartridge1 UVF model:+Double wavelength(254&185 nm)UV cartridge5000+1 Doulton UF cartridge1

18.2 M-cm @25OC <0.1ppb <10ppb < 0.001Eu/ml


<1/ml <1cfu/ml RO Water, Ultra pure water Automatic electronic pressure sensor controlling, RO membrane auto flushing, automatic stop without water, automatic stop when water tank full, automatic cutting off water when pump stopping, guaranteeing 24 hours work. TDS test pen + LCD online resistivity monitor Tap water:TDS<200ppm,5-40OC,1.0-3.5Kg/cm2 15/30 liters/hour* 1.5 L/min (with pressure tank) (Less output with UF/UV cartridge) 220V/50Hz, 48W/ plus model:72W HWD:424122cm / 12-14kg Main body(including:1 set cartridge)+ 3.2gallon tank

<5 ppb < 0.001Eu/ml

* Inlet water: TDS200ppm, 25OC, 50psi and 15% recovery rate. ** GPD=gallon per day 1gallon=3.8L. *** The quality of inlet water will effect outputs and cartridges life. PF:Pretreating, AC: Active carbon, RO:Reverse osmosis, DI: Ion exchange, UV:Ultraviolet(Double wavelength:254&185nm), UF:Ultrafiltration, TF:Terminal filter.

Consumables & accessories:


Model 171-2-000050 171-2-000051 171-2-000052 171-2-000053 171-2-000054 171-2-000055 171-2-000056 171-2-000057 171-2-000058 171-2-000059 171-2-000060 171-2-000061 171-2-000062 171-2-000063
pre-filter

Specs
Special spun fiber filter Special active carbon block filter post active carbon filter 100 GPD RO membrane Mixed bed resin cartridge Ultra pure polishing resin cartridge 0.22m terminal filter TDS test pen 5000 Doulton UF cartridge Double(185&254nm) wave length UV cartridge Double (185&254nm)wave lamp 10PP+resin soften water filter 10PP filter 10soften water resin filter

Replacement term
2-6 months* 4-6months* 1 year* 1-2 years Around 1000L Around 1000L

Lamp: about 9000h About 9000h 2-6month * Resin : 2-3month *

Remarks: * Replace term of Plus model will be decreased. ** When inlet waters TDS>200ppm, Replace term of filter will be suggested to decrease,or outside pre-filter is added. Or water quality and life of ultra pure cartridge will be affected.

Water purification systems WATER-PURIFICATION


WPG-100/200 Series, Water purification systems

Model Flow procedure Application Pure water quality Output Water quality monitor/ Pure water outlet External dimension/Power/Weigh Inlet water requirement Pretreatment unit Purification system RO unit Subsequent unit Standard configuration

WPG-100
PF+AC+RO+DI

WPG-200

ware washing Agricultural expe General biological expe Aquatic products feeding Inlet water for Ultra pure water machine Inlet water for sterilizer/T&H chamber Buffer disposing Aseptic drinking water Physical and chemical analysis Fine chemistry industry Resistivity of deionized water:>10M-cm, Desalination rate%:Nearly 100*, TDS(total dissolved solid)of RO water 5-10 ppm* 15 Liters per hour * 30 Liters per hour *

TDS(total dissolved solid)test pen/ RO Water, Deionization water WDH:413242cm / 220V 50Hz / About 15Kg Tap water :TDS<200ppm, 5-40OC, 1.0-3.5Kg/cm2 10 PP spun fiber filter1+10 granular active carbon filter1+10 active carbon block filter1 100GPD RO membrane x 1 Mixed bed resin cartridge-D2 100GPD RO membrane x 1 Mixed bed resin cartridge-D3

Main body(including:1 set cartridge)

* Inlet water: TDS200ppm, 25OC, 50psi and 15% recovery rate. ** GPD=gallon per day 1gallon=3.8L. *** The quality of inlet water will effect outputs and cartridges life. PF: Pretreating, AC: Active carbon, RO: Reverse osmosis, DI: Ion exchange.

Consumables & accessories:


Model 171-2-000070 171-2-000071 171-2-000072 171-2-000073 171-2-000074 Specs
10 PP spun fiber filter 10 granular active carbon filter 10 active carbon block filter 100GPD RO membrane Mixed bed resin cartridge-D

Replacement term
About 4-6 months* About 4-6 months* About 4-6 months* About 1-2 years About 1000liters

Vous aimerez peut-être aussi