Vous êtes sur la page 1sur 1

FAILURE ANALYSIS

The WEIDMANN failure analysis is a detailed review of the transformer internal components and/or remains of the failed transformer in association with a review of the original design parameters. Failure analysis coordinates both WEIDMANN expertise and laboratory analysis capability. The typical failure analysis usually identies the primary failure path within the transformer. This failure path is then analyzed using a nite element model to determine the actual stresses encountered in the transformer winding and insulation system. From the nite element analysis and stress determination we can determine whether or not areas of the insulation system experienced overstress or some outside component or agency initiated the failure. In addition to the nite element analysis, samples are typically removed from the failed transformer in and around the area of the failure. These samples are analyzed in WEIDMANNs laboratory for moisture content, contamination, type of discharge path, and other pertinent type of analysis. The value of the detailed failure analysis report is to describe the type of failure that occurred and the stresses encountered in the transformer at the area of the failure. In addition, the results of analytical tests determine whether or not high moisture content or outside contamination contributed to the failure of the power transformer. A detailed report on the cause of the failure is supplied to the repair company and/or end user of the transformer. D. C. dielectric tests - up to 200 kV DC including polarity reversal. Long term aging Temperature ) Electrical Stress )

or both

Includes facilities to process, dry, and oil impregnate samples and test xtures with transformer oil. 2. Low Voltage Lab Testing - Q.A. of WEIDMANN products, material comparisons new product development. Solids Dissipation factor Volume and surface resistivity Dielectric constant Moisture content % oil impregnation and rate of impregnation Oil Testing Dissipation factor Volume resistivity Dielectric constant Moisture content VDE breakdown Physical Testing - Mechanical Lab - Q.A. of our products, testing other material for usefulness in insulation systems, product development. Tensile strength Ply adhesion Shrinkage Density Compression Bending Elongation Engineering for Failure Analysis Package Project Design review of original design specication and parameters (Design Synthesis) Failure Analysis Field plot design analysis, Teardown analysis Model tests (if required)

ENGINEERING AND LABORATORY TESTING SERVICES


The following tests can be performed independently or as part of a failure analysis package project: 1. High Voltage Electrical Tests - In oil and/or Air Standard tests and specialized test sequences. Test models designed and constructed. Test xtures designed and constructed. Test electrodes designed and constructed. 60 HZ - up to 250 kV Creep - surface strength Puncture Impulse - up to 800 kV, including full wave, chopped wave, and front of wave tests. Creep Puncture

Rev. 03.12

WEIDMANN DIAGNOSTIC SOLUTIONS INC. One Gordon Mills Way, PO Box 799, St. Johnsbury, VT 05819-0799, USA T +800 242 6748, +802 748 8106, F +802 748 8630, www.weidmann-electrical.com
A Member of the WICOR Group