PowerEdge M1000e Administration and Configuration

PowerEdge M1000e Administration and Configuration

iSCSI is:
Block level storage Standards based: Open standard for SCSI over IP Ratified by IETF standards committee iSCSI performs extremely well: Switched Gb Ethernet outperforms 1Gb Fibre 124 MB/sec per interface 10 Gb-Ethernet iSCSI deployments to be available in the future iSCSI is a secure, reliable storage

Security built-in to standard (IPSec, VLANs, CHAP)


Multilayer access control (IP address, Initiator, CHAPs) Switched GbE is point to point, full duplex iSCSI exploits existing IP knowledge base: Leverages existing network management tools (SNMP, etc.) Is a consistent protocol with WAN and LAN infrastructures Reduces interoperability issues: IP standards are mature

PowerEdge M1000e Administration and Configuration

What is iSCSI? iSCSI defines how storage traffic is handled across a TCP/IP network in the following suite of RFCs: RFC 3720 iSCSI RFC 3721 Naming and Discovery RFC 3722 String Names RFC 3723 Securing Block IP Protocols Provides all the benefits of a SAN: MPIO, Boot from SAN, Clustering, HBAs, and SAN backup

iSCSI uses a combination of two familiar networking technologies:


Gigabit Ethernet Data Link level protocol to connect between a server and a level 2 switch: Uses a MAC address to route between the two Uses flow control to control the traffic Uses jumbo frames (9000 byte) TCP/IP Routing protocol Guaranteed delivery system Storage traffic uses the familiar SCSI protocol to perform SCSI reads and writes to storage devices from a server

PowerEdge M1000e Administration and Configuration

iSCSI initiators issue SCSI commands Commands are Read, Write or Status Commands are used to request services from components (logical unit known as a target) iSCSI targets service the requests from the initiator

iSCSI transmits and receives block storage applications over TCP/IP networks by encapsulating SCSI commands into TCP and transporting them over the network via IP
iSCSI deployments: Initial deployments are commonly project-oriented: Deal with lack of storage for email, databases, and new applications Provide storage consolidation Improve the storage management feature set provided by DAS After initial deployment, SAN becomes infrastructure: Expanded use for existing applications New servers and applications

New IT operations
Disk-to-disk backup Snapshot-based backups Disaster protection

PowerEdge M1000e Administration and Configuration

iSCSI requires that the iSCSI initiator and target nodes have one of two types of names. Name types: IQN, iSCSI qualified names Example: iqn.2001-05.com.equallogic:6-8a0900-9f46a0201be4ff0d21dd428df-testvoulume1

Format
Reverse DNS naming equallogic.com = com.equallogic Naming Authority would add a unique string of characters EUI (enterprise unique identifier) Example: eui.abcde49123779abcd Format Formed using the IEEE EUI (Extended Unique Identifier) format (16 hex characters) High 24 bits is the company id, which is IEEE assigned Low 40 bits is the manufacturer assigned value preceded by the date that the name was assigned Both are intended to be long lived and unique. Both are controlled by a central naming authority such as a department within the corporation. The default iSCSI protocol port number is 3260.

PowerEdge M1000e Administration and Configuration

PowerEdge M1000e Administration and Configuration

Logging on to the iSCSI target will make the volume visible to this host. To log on to the target: From the Targets tab, highlight the target you will attach to Press the Log On button When Log On to Target appears, select the Automatically restore this connection when the system reboots checkbox and press OK Select the Persistent Targets tab and confirm that the iSCSI name of the target is listed

PowerEdge M1000e Administration and Configuration

When a login occurs: The first login request goes to the PS Series group IP address. Within the response that is returned to the initiator, there is a Status class field indicating that the initiator must login to another IP address. In the case of the PS Series, this IP address will effectively be the least busy port. Initially, the login process appears to be round-robin but as traffic starts to flow, the least busy port or the port with the fewest connections is chosen. Then, the initiator is redirected to the least busy port and logs in to that IP address. This process of redirection is normal and fully covered in the iSCSI spec. It is also used in other ways with the PS Series: If you have a connection to eth2 and if for some reason the switch port that eth2 is connected to fails, then the initiator will retry the current port briefly, and then attempt to log in to the group IP address again. Once again, it would be redirected to another port. While the user may see a brief blip in performance, redirection should not cause errors.

PowerEdge M1000e Administration and Configuration

PowerEdge M1000e Administration and Configuration

10

Network Configuration Choices Private network Requires separate switch Can be inappropriate for some deployments Separate Subnet/VLAN Most common Can use switch level access control for SAN Port blocking (iSCSI uses port 3260) Address filtering LAN (merged LAN and SAN) May be required with software initiators on desktops or blade servers WAN Should be used with VPN or other encryption mechanisms Network Switch Options Flow control Ability of receiver to slow down a sender to avoid packet loss Unicast storm control Switch feature to control storms; must be disabled on SAN ports Spanning Tree Switch capability to detect loops in multiple switch configurations Lengthens time for ports to become usable; should be shortened in SANs (or avoided). Separate vs. shared subnets (Layer 2 vs. Layer 3) VLANs allow for separate network traffic while using the same switch infrastructure VLANs are separate subnets; adds requirement for L3 switches Jumbo Frames Allow larger packet sizes (~9000 bytes vs. 1500 bytes) Can help improve performance, especially with software initiators

PowerEdge M1000e Administration and Configuration

11

General iSCSI traffic guidelines: iSCSI traffic tends to be "bursty" with large amounts of data coming all at once followed by idle periods. The switch needs enough bandwidth to handle the bursts AND enough buffer space to buffer packets for other, less fortunate members of the network. Those members may not able to handle full speed bursts and must use flow control to mitigate the incoming data. General GE Switch guidelines: Ideally, the switching fabric should be able to handle 2 Gbps times the number of ports (because the traffic is full duplex). So, a 24-port switch should have an internal speed of at least 48 Gbps. For buffer space, a figure of at least 512KB per port seems to be a good starting point. The reason for emphasizing per port is that some switches are designed so that multiple ports share the same buffer space (and sometimes the same fabric interconnection). This means that if only one port in this group is passing traffic, then it has plenty of buffer space and/or bandwidth. As soon as you start passing traffic on multiple ports, and the space and/or bandwidth needs to be divided among the ports, there is no longer enough available per port to do the job. Jumbo frames guidelines: The maximum frame size that the PS Series can currently handle is 9014 bytes. Some manufacturers of network equipment call this "9000 bytes"; it depends on whether they count the 14-byte Ethernet header as part of the frame or not. We recommend that you not set the jumbo frame size on your switch to anything more than 9014 (or 9000) bytes. Trunks, ISLs, and Stack cables Recommend stacking cables if available or if not available then sufficient Trunk, ISLs, to support the load. Rule of thumb is 1 trunk for each active port within the group.

PowerEdge M1000e Administration and Configuration

12

PowerEdge M1000e Administration and Configuration

13

PowerEdge M1000e Administration and Configuration

14