Simple level switch for high temperature/
pressure applications
Switches wire directly to a PLC/SCADA or con-
troller
SwitchescanbeconvertedinthefeldfromNO
toNC
316 SS level sensor for high temp and pressure
applications
DrycontactreedswitchselectableNOorNCviafoat
orientation
Offeredinbothverticalandhorizontalmounting
confgurationsforhighorlowlevelpointdetection
Switch-Tek LV3X & LH35 High-Temp Float Level Switch

2010FlowlineInc.10500HumboltStreetLosAlamitos,CA90720562.598.3015www.fowline.comDS300504REVA
Features Key Benefts
Offeredinbothverticalandhorizontalconfgurations,
the general purpose high-temp foat level switches
provide reliable liquid level detection of relatively
clean water, diluted chemicals and light weight oils
with a 30VA or 100VA reed switch output. Media
examplesincludehotdeionizedwaterandcookingoil.
The stainless steel liquid level sensors are mounted
vertically inside the tank or horizontally through the
tankwallasahighlevelalarmorlowlevelalarm.
Application
IP
68

Switch-Pro
Compact Level Controller
LC1X
Thegeneralpurposelevelcontrollerisofferedintwoconfgurationsforpumpand
valve control. The LC10 accepts one level sensor input and provides one 16A relay
for high level control or low level control. The LC11 accepts two level sensor inputs
andprovidesonelatching16Arelayforautomaticflloremptycontrol.Theoptional
fashalarmbringsattentiontolevelalarmconditions.Packagethislevelcontroller
withourliquidlevelswitchsensorsandfttings.
Application
Compatible Products
LC4X
Switch-Pro
RemoteLevelController
Available in general purpose classifcation, the level controller is offered in three
confgurationsforpumpandvalvecontrol.TheLC40acceptsonelevelsensorinput
andprovidesone10Arelay.TheLC41acceptstwolevelsensorinputsandprovides
onelatching10Arelayforautomaticflloremptycontrol.TheLC42acceptsthree
level sensor inputs with one latching 10A relay output for automatic fll or empty
control,andasecondnon-latching10Arelayforhighlevelalarmorlowlevelalarm.
Forfeldmountinstallation,addasingleordualindicatorNEMAbox.
Application
Ordering Notes
1) The normally open or closed contact output is
selectable based on the installed orientation of
the float.
Maximum pressure (1)
5 300 psi (20.7 bar)

LV3 -S201
Switch-Tek Vertical High-Temp Float Level Switch
LV30-32 Series
Float
Maximum pressure (1)
5 500 psi (34.5 bar)
LH3 -S201
Vertical
Horizontal
6 500 psi (34.5 bar)
Switch-Tek LV3X & LH35 High-Temp Float Level Switch

2010FlowlineInc.10500HumboltStreetLosAlamitos,CA90720562.598.3015www.fowline.comDS300504REVA
The normally open or closed contact output is 1)
selectable based on the installed orientation
ofthefoat.
Specifcations
Orientation: LV3X:20vertical
LH35:20horizontal
Accuracy: 3mminwater
Repeatability: 1mminwater
Specifcgravity: LV3X:0.7minimum
LH35:0.6minimum
Contacttype: (1)SPSTreed
Contactrating: LX35:30VA
LV36:100VA
Contactoutput: SelectableNO/NC
Processtemp.: F:-40to392
C:-40to200
Pressure: LV35:300psi(20.7bar)
LV36:500psi(34.5bar)
LH35:300psi(20.7bar)
Sensorrating: NEMA6(IP68)
Sensormaterial: 316SS
Wirejack.mat.: Polymeric
Wiretype: 2-conductor
Wirelength: 2(61cm)
Processmount: LV35:1/8NPT
LV36:1/4NPT
LH35:1/2NPT
Classifcation: Generalpurpose
Compliance: CE
Notes
Ordering
Dimensions
Accessories
P/N Description
Single & Two Controller NEMA Box
LM94-1001 SingleController,
Windowed,35mmRail,PC
LM95-1001 TwoController,Windowed,
35mmRail,PC
Protect your level controller from the elements by using the below
recommendedsingleortwoindicatorNEMAbox.

1/2-14 NPT
NO
1/2-14 NPT
4.60" max.
(116.8)
0.81" min.
(20.6)
1.22" max.
(31.0)
1.15" max.
(29.2)
Approximate
Actuation Level
Fitting
Centerline
.10"
(2.5)
Wire Leads
LV35
LH35
2"
(50.8)
1/4" NPT
3.38"
(85.8)
2.63"
(66.8)
2.13" (54.1) dia. max.