Académique Documents
Professionnel Documents
Culture Documents
New Features
January 2007
DINS-08.00.0014A
Copyright
Copyright 1995-2007 Intergraph Corporation. All Rights Reserved. Including software, file formats, and audiovisual displays; may be used pursuant to applicable software license agreement; contains confidential and proprietary information of Intergraph and/or third parties which is protected by copyright law, trade secret law, and international treaty, and may not be provided or otherwise made available without proper authorization.
Trademarks
Intergraph, the Intergraph logo, PDS, SmartPlant, SmartSketch, FrameWorks, INtools, MARIAN, ISOGEN, and IntelliShip are registered trademarks and SupportModeler and SupportManager are trademarks of Intergraph Corporation. Microsoft and Windows are registered trademarks of Microsoft Corporation. MicroStation is a registered trademark of Bentley Systems, Inc. Other brands and product names are trademarks of their respective owners.
Table of Contents
Table of Contents
Preface.................................................................................................................................4 New Features in SmartPlant Instrumentation 2007 .......................................................5
General................................................................................................................................ 5 Administration .................................................................................................................... 6 As-Built and Projects .......................................................................................................... 6 Browser Manager................................................................................................................ 7 Database Initialization ........................................................................................................ 8 Database Maintenance ........................................................................................................ 8 DCS Vendor Interfaces ....................................................................................................... 8 Dimensional Data for Piping .............................................................................................. 8 Documents, Reports, and Revisions ................................................................................... 9 Enhanced Reports ............................................................................................................... 9 Explorer Windows ............................................................................................................ 10 Fieldbus............................................................................................................................. 10 Hook-Up Drawings........................................................................................................... 11 Instrumentation Maintenance............................................................................................ 12 Interface to SmartPlant Electrical ..................................................................................... 12 KKS .................................................................................................................................. 12 Loop Drawings ................................................................................................................. 13 Multi-Input Devices .......................................................................................................... 13 Process Data...................................................................................................................... 14 Save as Excel .................................................................................................................... 14 SmartPlant Integration ...................................................................................................... 14 Specifications.................................................................................................................... 14 Wiring ............................................................................................................................... 16
I/O Assignment ........................................................................................................................16 Wiring Equipment....................................................................................................................16 Wiring and Control System Instrument Type Profile...............................................................17 Cables, Cable Sets, and Wires..................................................................................................17 Connections and Signal Propagation........................................................................................17 Conventional and Device Panels..............................................................................................18 Reports .....................................................................................................................................18
Preface
Preface
This guide describes the new features of SmartPlant Instrumentation Version 2007. Send documentation comments or suggestions to PPMdoc@intergraph.com.
3
Administration
Flexible Naming Convention Replaces Previous Standards The flexible naming convention now replaces all previous naming convention standards for all item types, allowing you to set your naming convention without any limitations. Naming Convention Per Tag Class The naming convention is now set per tag class within a specific unit. Removing Deleted Windows Users from SmartPlant Instrumentation If you enabled the use of Windows authentication logon method in SmartPlant Instrumentation, the software now automatically detects those users who have been deleted from Windows groups and allows you to permanently remove these users from SmartPlant Instrumentation.
New Features in SmartPlant Instrumentation 2007 Merging Items Without Deletion from the Project The System Administrator can set the software to merge items without deleting them from the project. After making this setting, on merging project data with As-Built, view-only copies of merged items remain in the project. You cannot delete these copies or update their properties. However you can claim these items for another project even if you are working in exclusive claim mode. Displaying As-Built Item Properties in a Project When working in a project with As-Built items displayed, in the Domain Explorer, it is now possible to select an As-Built items and open a view-only dialog box showing the item properties. Claiming Control System Tags with DCS Panels When claiming a DCS panel with all of the panel sub-items, the software now also claims the associated control system tags. Copying Project Items to the Merge Buffer Using the Domain Explorer In a project opened in an Operating owner domain, in the Domain Explorer, you can now select items you want to merge with As-Built and copy them to the Merge Buffer for further processing from the Administration module or for merging the copied items using command line parameters. Claiming Items from One Project to Another When working in non-exclusive claim mode, a Project Administrator can now select a project as a claim source and then claim the project data for another project in the same Operating owner domain. Previously, it was only possible to use As-Built as a claim source. Updating Properties of Items Previously Claimed as Dummy Items When converting a dummy item to a fully-functional item by claiming this item again from As-Built, the software now updates the item properties using the As-Built item properties as a source.
Browser Manager
Archive Browser SmartPlant Instrumentation now allows you to view all archived documents in the Archive Browser. For certain documents (such as process data, manufacturer), you can perform a comparison between archives of the same document.
New Features in SmartPlant Instrumentation 2007 Log Browsers You can now generate reports that show when changes were made to specific documents. You can generate reports for Cables, Control System Tags, Equipment, Instruments, Lines, Loops, Panels, and Wiring Equipment.
Database Initialization
Initializing a Database Using SmartPlant Engineering Manager You can now perform many database activities using SmartPlant Engineering Manager. Note that once you initialize a database from SmartPlant Engineering Manager, you can no longer use the equivalent actions in the Administration module. For details of specific activities that you can perform from SmartPlant Engineering Manager, see the SmartPlant Engineering Manager User's Guide.
Database Maintenance
INTOOLS_ENGINEERING Role Removed from the System Account The DB Setup Utility no longer grants the INTOOLS_ENGINEERING role to the System account of the Oracle database. Creating the INTOOLS_ENGINEERING Role Without a Password The DB Setup Utility now creates the INTOOLS_ENGINEERING role without a password. If your corporate security requires this role have a password, you can define the password manually after completing the SmartPlant Instrumentation database setup. Previously, the INTOOLS_ENGINEERING role was created with the INTOOLS_ENGINEERING password.
Enhanced Reports
Cable Block Diagrams SmartPlant Instrumentation now allows you to create and view Cable Block Diagrams using the Enhanced Report Utility. CS Tags in Enhanced Reports You can now display CS tags with a loop reference in enhanced reports. Displaying Tags-with-Wiring in Enhanced Reports Blocks (Symbols with Macros) Only macros that apply to the tag number entity type can be used in the Enhanced Reports blocks. These macros can retrieve information from the Instrument Index, instrument custom fields and user-defined tables, process data, calculation, calibration or spec modules. Macros pointing elsewhere will be ignored. Resolving Macros Within Customized Enhanced Report Symbols You can place macros directly on the .sym files used for enhanced reports, attach them to an item, and resolve the macros within symbols. (This refers to custom mode; for shipped symbols it is already implemented).
Explorer Windows
Virtual Tags in the Domain Tree View The software now places virtual tags in the Domain Explorer tree view as child items of Fieldbus tags in the Fieldbus Segments folder. SmartPlant Instrumentation Explorer Custom Views SmartPlant Instrumentation allows you to define custom views for the Domain Explorer and the Reference Explorer. The software lets you select a folder or multiple folders and add these folders with their child items to a custom view that you select. Note that the custom views that you define are not available to other users of SmartPlant Instrumentation. Filtering Items SmartPlant Instrumentation now has an improved filtering mechanism that allows you to set a filter based on an item type or an item name. Item type filters can be applied to an entire tree view of the active Explorer window or to a selected folder or node that contains child items. Item name filters are set for the whole tree view of the active Explorer window. Note that filter definitions are applicable to custom views of the Domain or Reference Explorer. Creating Panel Manufacturer Sub-Folders A new folder is available for telecom panels that are arranged according to panel manufacturer. This folder holds panel manufacturer sub-folders where the appropriate panels reside. You can create your own panel manufacturer sub-folders and once you associate a telecom panel with a particular manufacturer, the panel will become available in that folder.
Fieldbus
Terminators on Connected Terminals SmartPlant Instrumentation no longer prevents you from creating terminator on terminals that have already been connected to wires. Sorting the Associated Segments in the Connection Window When associating a segment with a home-run cable in the Connection window, the items on the Associate segment select list have been sorted alphabetically. Segment Notes on Segment Properties Dialog Box You can now add a brief note when editing the properties of a Foundation Fieldbus segment, Profibus DP segment, and Profibus PA segment.
New Features in SmartPlant Instrumentation 2007 Segment Name on the Tag Properties Dialog Box The software now displays the name of the associated segment on the Fieldbus tab of the Tag Number Properties dialog box. Profibus Segments in the Segments Folder of the Domain Explorer In addition to Foundation Fieldbus segments, the Segments folder of the Domain Explorer now contains Profibus DP and Profibus PA segments. Setting in a Multi-Input Device for an Instrument to Appear in Segment I/O Assignment When creating a multi-input device panel, the software now allows you to set an input terminal or connector to appear in the segment I/O assignment. DP Segments in the Fieldbus I/O Assignment The software now allows you to select DP segments when effecting Fieldbus I/O assignment.
Hook-Up Drawings
Opening Hook-Up Reports by Selecting Document Numbers You can now open a group of reports by selecting the document numbers of previously generated reports. Hook-Ups in Enhanced Report Format It is now possible to generate hook-up drawings using the Enhanced Report Utility. Reorganization of Hook-Up Management Options Hook-up creation, management, and assignment options have been moved from the Hook-Up Manager to the Domain Explorer. Hook-up item library options have been moved to the Reference Explorer. The Hook-Up Manager has been removed from the software. Generating External Hook-Up Drawings Using the Enhanced Report Utility Using the Enhanced Report utility you can generate hook-up drawings originating in AutoCAD, MicroStation and SmartSketch. Hook-up drawings comprise of a drawing, a title block, a block, and macros within the block. The Enhanced Report utility handles each format differently. Support of AutoCAD 2005 and 2006 You can now generate hook-up drawings using AutoCAD 2005 or 2006.
Instrumentation Maintenance
Maintenance Event Records It is possible to create records of repairs, tests, inspections, calibrations, and so forth. These records are called maintenance event records. You can associate several maintenance event records with a particular instrument, provided that this instrument belongs to one of the following tag classes: Conventional, Fieldbus, HART, or Profibus. Note that for an Operating owner domain, this option applies to instruments in As-Built only.
KKS
KKS Support Support for KKS mode includes the following features:
When copying a unit, the software implements special handling of KKS conventions (PBS/Total plant and cable numbering). KKS supports naming conventions for Fieldbus, Profibus, HART, and Telecom tags as well as for virtual tags. When editing cable names where the application area or system classification was changed, the software provides an option to suggest new cable numbering. For terminal properties, a calculated field is used for the connection identification. This field consists of the strip name and terminal number, for example '-X:+1'. Control system tags inherit their names from the associated instrument tag numbers.
Loop Drawings
Associating CAD Drawing Blocks to Loop Number It is now possible to assign a CAD drawing block to the loop number. After associating a block with a loop, when generating a loop drawing, the software always uses the loop block and ignores any instrument blocks that this loop might contain. Dissociating CAD Drawings from Loop Number It is now possible to dissociate from a loop number a CAD loop drawing that was created outside the SmartPlant Instrumentation environment. Copying Automatically Associated Blocks It is now possible to copy CAD drawing blocks from all instrument tags of a specific loop to all instruments of one or more target loops. You copy automatically assigned blocks at the <plant> level to loops belonging to different <units> of the current plant. The block that you can copy must be assigned to the source loop automatically (via the instrument type). Managing CAD Loop Blocks You can now manage CAD drawing block types and blocks in the Domain Explorer. Reorganization of Loop Drawing Management Options Loop drawing generation, block assignment, and loop drawing property management options have been moved from the Loop Manager to the Domain Explorer. The Loop Manager has been removed from the software. Support of AutoCAD 2006 You can now generate loop drawings using AutoCAD 2006.
Multi-Input Devices
Defining a New Terminal Configuration When creating a convention multi-input device panel, the Multi-Input Field Device wizard now allows you to define a new terminal configuration. Clicking the Ellipsis button on the Define the Input/Output Configuration page of the wizard opens the Terminal Configuration dialog box. Recognizing Signals From Distant Device Panels Now multi-input devices can recognize input signals from distant device panels.
Process Data
Duplicating Lines You can now duplicate lines along with their matching ansi/din piping data from the index module (similar to tag duplication).
Save as Excel
Support for Excel 2003 SmartPlant Instrumentation now supports saving specifications as .xls files using Excel 2003, in addition to previously supported Excel 2000 and Excel XP.
SmartPlant Integration
Improved Implementation of Schema Mapping Custom fields are used for defining new properties for mapping, and appropriate supporting tables are used for defining new values in enumerated lists (select lists). Publishing Wiring Reports Several wiring reports can now be published from SmartPlant Instrumentation. Upgrading the Map Schema A new command, Upgrade Schema, is available on the SmartPlant menu. This command updates the IntoolsMap.xml file with schema changes that you may have made in a previous version of the software.
Specifications
Specifying a Fluid State for a Form Data Template The Select Fluid State pop-up window no longer appears when you open a form data template. When you open a new form data template, you can select a fluid state from the appropriate select list. In an existing form data template, the software always displays the fluid state you selected previously. The Select Fluid State pop-up window only appears when you try to open a specification for an instrument that does not have process data defined. Filtering Spec Revisions by Form Number When managing or printing spec revisions in the Specifications module, you can now filter revisions by form number.
New Features in SmartPlant Instrumentation 2007 Filtering Spec Revisions by Plant Hierarchy Item When managing or printing spec revisions in the Specifications module, you can now filter revisions by a plant hierarchy item. For example, you can set the software to display a particular revision that you created in the current < unit>. Sorting Spec Pages Alphabetically According to Page Name On the Select Specification Page dialog box, where you select a spec page for displaying in the Page Editor, the pages are now always sorted alphabetically according to page name. It is possible to sort pages by double-clicking one of the following column headers of the dialog box: Specification Page, Description, or Notes. Double-clicking a column header sorts the pages in ascending order. Doubleclicking a column header again sorts the pages in descending order. Text Wrapping in a Multi-Tag List In a multi-tag list, the software automatically wraps value strings that do not fix the column width. Displaying a Sorted List of Multi-Tag Spec Document Numbers On the New Specification dialog box, multi-tag spec document numbers now appear sorted alphanumerically in ascending order. Treating Source Fields that Have Spaces as Blank Fields When copying data from a form data template or a specification to another specification, the software now treats source fields that only have spaces as fields that contain no value. Instrument Composite Specifications It is now possible to generate a specification that can include instrument tags belonging to the same loop or to different loops. In contrast to multi-tag instrument specifications, which contain pages of common properties in addition to the SEE LIST page, such composite specs do not have common pages and can include tags whose process functions are not identical. Also, it is possible to create a composite spec that includes process data cases of a particular instrument. Loop Composite Specifications It is now possible to generate a specification for a loop and its instrument tags. Such a specification is called a loop composite specification because the pages contain several sections: one for the loop number and the other for the loop instrument tags. All of the sections can appear on the same page of the generated specification.
Wiring
I/O Assignment
I/O Assignment Options for Instrument Tags with Changed Wiring When making changes in the wiring for instrument tags for which I/O assignment has been defined, the software detects these changes and lets you select an appropriate option that deals with the I/O assignment of the affected instrument tags. You can shift the I/O assignment to a new channel, remove the existing I/O assignment, retain the existing I/O assignment and create a new one for the same signal, or simply undo the current action in the Connection or I/O Assignment window. Shifting Instruments in the I/O Assignment Window You can shift the assignment of an instrument to another unassigned channel by simply pressing and holding the Ctrl key while dragging the instrument to another unassigned channel. You cannot change the assignment this way if the target channel has already been assigned to another instrument. Note that when changing the assignment, the software retains the existing control system data. Showing Assigned Channels Claimed by Other Projects When working in a project, the I/O Assignment window now allows you to see assigned channels that have been claimed by other projects. You can also see assigned channels that belong to As-Built. These channels are displayed in red and there is an icon to the left of the assigned channel that indicates that you can click this icon to see which project the channel is claimed for.
Wiring Equipment
Associating I/O Terminations with I/O Cards The software now provides you with a more efficient way to associate I/O terminations with I/O cards. When editing the properties of an I/O termination, you no longer need to select a cabinet, rack, and slot in order to get to the I/O card that you want to associate. You can select an appropriate I/O card from the Domain Explorer and on the I/O Termination Properties dialog box, the software will automatically show which cabinet, rack, and slot that it belongs to.
New Features in SmartPlant Instrumentation 2007 Making Connections on the Right Side of DCS and PLC Panels SmartPlant Instrumentation now allows you to make connections on the right side of DCS and PLC panels. Note, however, that connections on the right side increase the signal level by one. Creating Multiple Jumpers The software now allows you to create and connect multiple jumpers in a repetitive way. You can define constant gaps between the jumpered terminals if required. Also, you can jumper the last remaining terminal in the selected terminal pattern if required. Automatic Creation of Signals When Associating Non-Wiring Instruments with Connected Cables, Cable Sets, or Wires This feature makes it possible to associate a conventional or electrical non-wiring instrument with a connected wire, cable set, or cable. Dragging such an instrument from the Instruments folder of the Domain Explorer to a connected wire, cable set, or cable in the Connection window automatically creates a signal from that instrument and propagates this signal along the connected wiring path. Note that non-wiring instruments are instruments that were created based on instrument type profiles that have no wiring.
Reports
Restarting Panel-Strip Report Pagination When not previewing a report before printing, the software allows you to set a preference that restarts the pagination of the report for each terminal strip. This preference is available for reports with adjacent connections only.
New Features in SmartPlant Instrumentation 2007 Filtering Items by Section for Cable Routing Reports When generating a cable routing report, you can now filter the selection of items by section. Also, when generating a drum summary report, you can filter the selections by pulling area. Showing Cable Gland Data in Cable Schedule Reports Cable schedule with routing reports now display cable gland data. Channel Addresses on DCS I/O Map Reports DCS I/O map reports now show I/O channel addresses. Number of Ports on Junction Box Reports The software now displays the number of ports when generating junction box reports (Wiring Reports > Plant Panel List > Junction Box). Showing I/O Channel Data in Panel-Strip Reports You can set a preference that will instruct the software to display I/O channel data in panel-strip reports. The software can display I/O channels, apparatus channels, and non-I/O channels.