Product Description
Product Description

COROMAX
Control Systems

Technical Description
Following for guidance only

COROMAX pulse system Mark III


The introduction in 1990 of the FLS COROMAX Mark III pulse energization system represented an important technical and economical advancement in pulse technology, made possible by the latest developments in high voltage thyristor technique. In COROMAX Mark III the pulse-firing switch operates at high potential whereby the pulse transformer required in Mark I and II can be eliminated. This results in significant savings in volume, price, and installation costs. The system becomes very compact, comprising one oil-filled tank only and a control cabinet. Physically the Mark III system is very similar to the traditional transformer-rectifier set. Pressure alarm Terminal box Temperature alarm Grounding switch

The FLS COROMAX Mark III system consists of: A. A DC high voltage supply comprising a three-phase transformer/rectifier with blocking reactor, a pulse power supply comprising a three-phase transformer/rectifier with blocking reactor, a storage capacitor, thyristor switch with return diodes, and a series inductance, all placed in a common oil-filled tank together with a firing and protection unit for the thyristor switch, and current shunts and voltage dividers for measuring purposes. A control cabinet containing circuit breakers, main contactor, thyristor controller for the DC high voltage supply, thyristor controller for the pulse power supply, thyristor firing unit, and the PIACS-COROMAX automatic control unit.

B.

The oil-filled tank with the DC and pulse power supply is placed on the precipitator roof, and its high voltage bushing connected to the precipitator section by means of a busbar in steel trunking. The control cabinet, which must be placed in a suitable dust free environment at distances varying from a few meters up to 100 meters or more from the tank, is connected to the tank by two threephase power cables and one screened multicore signal cable. The installation of the system thus is practically as simple as for a conventional DC power supply.

Product Description

The COROMAX Mark III system is designed for base voltages of max. 40 kV or max. 60 kV, a nominal pulse voltage of up to 70 kV, a nominal pulse width of 140 microseconds, and a pulse repetition frequency of up to 200 pps. It is available in two standard unit sizes with nominal ratings of 57.5 and 115 nF. The largest of these is capable of energizing a precipitator collecting plate area of up to around 4000 square meter.

PIACS-COROMAX
PIACS-COROMAX is the registered trade mark for the microprocessor-based control unit for manual and automatic operation of the COROMAX pulse energization system. The PIACSCOROMAX is installed in the control cabinet of the pulse system. The control panel of the PIACS-COROMAX contains analogue instruments, LCD (liquid crystal display), keyboard and push buttons for display and setting of operating and control parameters. The PIACS-COROMAX monitors the pulse system (corona current, sparks during pulse, sparks between pulses) and automatically controls the DC base voltage, the pulse amplitude (pulse voltage) and the pulse repetition frequency in accordance with a programmed control strategy aiming at maintaining maximum precipitator efficiency. LCD-display

PIACS COROMAX
%

IE

225 mA

C1F1
115 nF, 60 kV DC, 800 mA

I E

U DC
IT CORONA SEARCH

IE

U PULSE

7 4 1 0

8 5 2
PASSWORD

9 6 3
ENTER/ RESET

IE LIMIT

IC SET

U pulse

U DC

PULSE SUPPLY

U DC SET BACK

U DC LIMIT

U PULSE LIMIT

PULSE SPARK RATE

PULSE REP. RATE

PULSE SPARK SET RATE

PULSE REP. RATE LIMIT

T FAST RAMP

STATUS

DC SPARK RATE

U PULSE SET BACK

EMCS

MANUAL

Star/stop buttons for pulse system

Operating keys

The PIACS COROMAX incorporates: - Easy-to-use man/machine interface (MMI). - Soft-start with self-diagnosis routine. - Efficient spark detection with compensated voltage divider. - Classification of sparks according to their intensity and the time of their occurrence. - Advanced control strategies for the base and pulse voltage and the pulse repetition frequency.

F.L.Smidth Airtech is continuously improving its electrostatic precipitators and therefore reserves the right to change its technical specifications without prior warning. This description including appertaining sketches is a general description containing various options and solutions, which are not necessarily enclosed in a specific quotation. For details of the specific quotation please refer to the actual technical specifications.
VicR/EMB Rev 1A

Product Description

F.L.Smidth Airtech supplies Air Polution Control equipment: Electrostatic precipitators FabriClean pulse-jet fabric filters Gas conditioning towers Desulphurization systems COROMAX pulse systems PIACS microprocessor controllers and other advanced electrical control systems Dust transport and storage equipment All kinds of auxiliary equipment like fans, flue gas ducts, cyclones etc. We supply new equipment or upgrading of existing equipment no matter whether the existing equipment is supplied by us or not.