http://www.atecsrl.it/anlysubp.htm
15.12.2011
Page 2 of 3
Paint characteristics: - acid resistant - corrosive resistant - fungus resistant Thickness of the dry paint film 70-80 microns as minimun. 3.Electrical ATEC is structured to supply equipment suitable for installation in explosion hazardous area according to CENELEC rules. Cables carrying different signals types arel adeguately set apart to ensure integrity and prevent any . form of interference. Cable routing is arranged within the analyzer shelter according to the best engineering practice. Power distribution panels are provided with individual insulation circuit for each item complete with automatic circuit breakers and lamps; each electric motors are protected by a thermal cutout. J-boxes for alarm, analog and digital signal, serial link each one equipped with terminal strip considering adequate spare are installed outside the shelter. 4.Lighting system Internal and external systems are usually based on rapid start fluorescent type lamps using EEx-d lamp holders. 5.Utilities Utilities design is strictly depending on analysis application and plant availability. ATEC packages are engineered according to the following guidelines: - headers installed outside on the same side of sampling systems; - instrument air and water headers equipped with on line filtration unit; - each utility take-off will provided with an isolating valve; - vent header equipped with flame arrestor - steam and condensate headers will be thermal insulated. 6.Air conditioning and ventilating system Our application includes the supply of a redundant air conditioning and pressurizing system manufactured by ATEC. Further technical details on this item are available on dedicated ATEC brochure 7.Safety devices Our standard package includes the supply of a complete alarm control system based on the following equipment : - Differential pressure switch, to give alarm for low pressurization inside the shelter. - Flow switches (one for each ventilation fan) - Combustible gas monitors with the ancillary control unit - Toxic gas monitor with the ancillary control unit - Temperature switch for high temperature inside the shelter Contacts coming from the above apparatus are managed by shelter alarm control system based on PLC
http://www.atecsrl.it/anlysubp.htm
15.12.2011
Page 3 of 3
technology. The shelter are equipped with alarm annunciators according to ISA-1 standards both assembled in EExd enclosure according to CENELEC, for hazardous area. The alarm contacts available to control room are indipendent and insulated, Normally Open (NO) fail safe type with alarm condition at the de-energized state. 8.Sample handling systems Sample pre-conditioning, fast loop and sample conditioning/validation units are designed and engineered according to Customer specifictaions, process fluid characteristics and hold-up time in order to provide significant sample to analyzer. Standard liquid calibration/validation facilities include sample drum with nitrogen driven piston, level control, double block & bleed stream selection, portable sample collection bottle with quick coupling. Components are selected on the basis of high performance and material compatibility (stainless steel AISI 304, Hastelloy C276, PFA, PTFE). 9.Sample Recovery System Standard sample recovery system includes supporting rack, drum, level switches, local instruments (P1, T1), pump ADPE motor driven, valves and local panel with push buttons and selectors for local/remote control selection and for pump start/stop.
Home Company Profile Products&Services References Contact Us G.O.L.H. News Reserved Area
http://www.atecsrl.it/anlysubp.htm
15.12.2011