Analog Relative Analgesia N2O/O2 Mixer IS-100A

Accessories
1. Mixed Gas Supply Hose 2. Hose Fittings And Connectors 3. Silicone Airway Supply Tubing 4. Silicone Airway Scavenging Tubing. 5. Supply Gas Hoses

6. Three Liter Breathing Bag 3 4 5 6 7 7. Rolling Trolley or wall Mount Option 8. Silicone Masks, Available In Three Different Sizes OXYGEN DEMAND (Disposable Or Reuse) VALVE 9. Oxygen Demand Valve Resuscitator 10. Optional Hepa Filter Not Shown 9

Jheeta Medical Corp. 33 Marmaduke St. Toronto, Ontario, Canada M6R 1T1 / www.jheetamedical.com Tel: +1.416.817.4773

Analog Relative Analgesia N2O/O2 Mixer


FEATURES/APPLICATION
The IS-100A is a pain relief unit with adjustable analog control parameters. The unit enables a patient to accept an operation or treatment under his/her waking state without injection. This is achieved by controlling the percentage of N2O (laughing gas) in the (N2O/O2) gas mixture and the total flow of the mixed gas that is spontaneously inhaled by the patient. The end result is significant suppression of anxiety and sensation of pain during the procedure. Easy to use; no need for specialized equipment and does not require administration by an anesthesiologist. The density and flow of nitrous oxide /oxygen mixture can be adjusted during the procedure. Ideal for pediatric tooth extractions. Does not result in increased respiratory secretions. Will not affect breathing, the patient breathes independently during the procedure. Muscle relaxants are not required. The procedure is safe and reliable. The effects of the inhaled gas mixture ware off soon after administration of the gas mixture has stopped. Hypertension patients that use the nitrous oxide/oxygen inhalation device are stable; Vital signs such as electrocardiogram, blood pressure, pulse, respiration, and oxygen saturation remain stable during the procedure. There are no signs of stress-induced hypertension.

SPECIFICATIONS
Maximum total flow: 17L/min Precise flow: min 0.5L N2O: 0-70%; O2: 30%-100% Input pressure: 50PSI10% Input link: standard 5/8' DISS Patient output link: 15/22mm Double mask scavenger: optional Bag Tee: Emergency air valve Safe Valve: automatic on/off N2O Compensation proportion: Adjustable in 0-17L/min when the mixed density is stable O2 quick supplement: not less than 17L/min Designed and assembled in Canada

CONFIGURATION
Standard: Analog flow meter, bag tee, double mask scavenger, respiratory pipeline.  Optional: High-efficiency HEPA filter, autoclaveable mask, disposable mask, demand valve resuscitator, anesthetic gas scavenging unit.

The IS-100A is primarily used for pain relief in clinical childbirth and oral cavity operations; it is also used to reduce discomfort and pain during gastroscopy and endoscopy examinations.

Jheeta Medical Corp. 33 Marmaduke St. Toronto, Ontario, Canada M6R 1T1 / www.jheetamedical.com Tel: +1.416.817.4773

Digital Relative Analgesia N2O/O2 Mixer Accessories


1 2

1. Mixed Gas Supply Hose 2. Hose Fittings And Connectors

3. Silicone Airway Supply Tubing 4. Silicone Airway Scavenging Tubing. 5. Supply Gas Hoses

6. Three Liter Breathing Bag 7. Silicone Masks, Available In Three Different Sizes (Disposable Or Reuse) 8. Oxygen Demand Valve Resuscitator 9. Optional Hepa Filter Not Shown

Standard:

CONFIGURATION

Digital flow meter, bag tee, double mask scavenger, respiratory pipeline and power adaptor. Optional: High-efficiency HEPA filter, Autoclave-able mask, disposable mask, demand valve resuscitator. Anesthetic gas scavenging unit is also available.

Jheeta Medical Corp. 33 Marmaduke St. Toronto, Ontario, Canada M6R 1T1 / www.jheetamedical.com Tel: +1.416.817.4773

Digital Relative Analgesia N2O/O2 Mixer


Digital Display Multi Language Menu Minimum 30% O2 Low Flow Alarm Child /Adult Default Settings Battery Backup Portable Wall Or Trolley Mount Compatible With All Accessories That Are Available With The IS-100A

5000DS
FEATURES / APPLICATION

SPECIFICATIONS
Maximum total flow: 17L/min Precise flow: 0.5L/min N2O: 0-70%; O2: 30%-100% Input pressure: 50PSI10% Input link: standard 5/8' DISS Patient output link: 15/22mm Double mask scavenger: optional Bag Tee: Emergency air valve Safe Valve: automatic on/off N2O Compensation proportion: Adjustable in 0-17L/min when the mixed density is stable O2 quick supplement (O2 Flush): not less than 17L/min Designed and assembled in Canada

The 5000DS is a digital pain relief unit with adjustable control parameters and a human-machine interface with a screen that can display the specific control parameter settings. The unit enables a patient to accept an operation or treatment under his/her waking state without injection. This is achieved by controlling the percentage of N2O (laughing gas) in the (N2O/O2) gas mixture and the total flow of the mixed gas that is spontaneously inhaled by the patient. The end result is significant suppression of anxiety and sensation of pain during the procedure. The 5000DS is primarily used for pain relief in clinical childbirth and oral cavity operations; it is also used to reduce discomfort and pain during gastroscopy and endoscopy examinations.

Has all the features of the IS-100 Analog Analgesia machine as well as: 1. Greater accuracy and precision 2. Quick selection of child and adult default settings 3. Audible alarms 4. Battery backup

Jheeta Medical Corp. 33 Marmaduke St. Toronto, Ontario, Canada M6R 1T1 / www.jheetamedical.com Tel: +1.416.817.4773