FEATURES:
* Dual element pyrosensor * Pulse count selection * Sensitivity adjustment * Temperature compensation * RF Immunity * Tamper circuit * Input surge protection * Built in end of line resistor * High-Tech design * Hermetically sealed pyrosensor * Insect / rust protection on P .C.B. * Swivel mounting bracket included * Multipurpose LED selection - 90 minutes activation memory - Environmental Infrared Monitor * Computerized extensive testing and burn-in
INSTALLATION INSTRUCTIONS
MAMI
MANUFACTURING AND MINOR INVENTIONS (MAMI) TEL +27 (011) 452-4737, FAX +27 (011) 452-4738 South Africa e-mail: mami@icon.co.za Web site: www.mami.co.za
X00287 H.W_PIR2.CDR
2 3
SENSITIVITY ADJUSTMENT
There are 4 settings to adjust the sensitivity XL- For very stable surroundings (max. range) L - For stable surroundings (normal range) M - For unstable surroundings (reduced range) S - For very unstable environment(drastically reduced range.(4mt)
+ NC
RELAY LED
MEM MON ON
S L
(or off)
S L XL
SENSITIVITY ADJUSTMENT PIROSENSOR
M
(top view)
3 2 1
LED JUMPER
XL
TECHNICAL SPECIFICATIONS
Supply voltage: 10 to 16 V DC Current consumption: 13mA Relay: N.C. on stand-by Contact rating .1 Amp 28VDC WARM-UP DELAY : 2 min EOL Resistor: 2.7 Kohms Detection 0.15 to 3.2 m/sec
3 2 1 2 pulses, for Stable areas - medium & large masses detected (NORMAL SETTING) 3 2 1 3 pulses, for high unstable areas - only large masses detected
MEM MON ON
MEM MON ON
MEM MON ON
MEM MON ON
TEST PROCEDURE:
After applying power, wait 3 to 4 minutes before conducting any test and ensure that the protected area cleared of all people.
-+
RELAY N.C.
jumper
EOL
5 6
1 2 3 4
Walk Test:
1. Remove the front cover. Ensure that the pulse count is set to 3 and that the LED is enabled. 2. Replace the front cover. 3. Wait few seconds (5) to allow for the PIR to settle 4. Start walking slowly across the detection zone. 5. Observe that the detectors LED lights up whenever motion is detected. 6. After the walk test is completed, the LED may be disabled. 7. Allow 5 sec. Between each test for the detector to stabilize. 8 adjust the orientation of the detector to provide maximum coverage
Terminal 1 Connect to negative (-) supply Terminal 2 Connect to positive (+) 12v Terminal 3 & 4 This is a voltage free contact (closed= normal) (open on detection) Terminal 5 & 6 These are the N.C. Contacts of a tamper sw. Connect to a 24 Hour, Normally Closed zone.. NOTE: An End Of Line resistor can be automatically inserted in series with the circuit by REMOVING the EOL jumper The standard value is 2700 Ohms (2.7Kohms)
MOUNTING EXAMPLES:
12 o
+ -18
floor
For corner mount For (flat) wall mount
CABLING:
13
14
CONNECTIONS:
USING A KEY SWITCH TO BYPASS A ZONE WITH END OF LINE RESISTOR
2.1 mt
15
STANDARD TAMPER AND ZONE CONNECTION WITH END OF LINE RESISTOR
TAMPER CIRCUIT ZONE CIRCUIT
Bracket knock-out for cable Knock-out for 4-core cable Knock-out for 6-core cable
- + NC
FIRST DETECTOR
- + NC - + NC
TAMPER TAMPER
KEY-SWITCH
TAMPER
EOL= ON
EOL= OFF
LAST DETECTOR
- + NC
TAMPER
LAST DETECTOR
16
A
Wide Angle Array WA 1.2 GI 12 V3
23mt94 deg
9m 101deg
18.7m 134deg
12m 100deg
B
Dense Wide Angle Array DWA 1.2 GI 12 V2
F
Long Range Array LR 1.2 GI 12 V3 Vertical Barrier Array VB 1.2 GI V1
FIRST DETECTOR
Red
TM
ZONE CIRCUIT
POWER
-+
-+
EOL= ON
POWER
EOL= ON