GEA ENERGY SYSTEM (INDIA) LTD. POWER PROJECTS DIVISION VIJAYWADA TPS, STAGE IV, UNIT - 7, 1 X 500 MW SPECIFICATION FOR AC & DC MOTORS GID-064-EL-SA-2801
ANNEXURE 1 MOTOR DATA SHEET
1.00 1.01 1.02 1.03 1.04 1.05 2.00 2.01 2.02 GENERAL Application Quantity Make Frame Size Applicable Standards TYPE AND RATING Type of Motor Service i) Outdoor / Indoor ii) Hazardous areas classification if any 2.03 2.04 Dute Cycle / Designation Rated Power Output i) at 40 deg. ambient ii) at 50 deg. ambient 2.05 2.06 2.07 2.08 2.09 2.10 2.11 Rated Speed Rated Voltage & % Variation Rated Frequency & % Variation Full Load Current No Load Current Rated Power Factor Efficiency at rated voltage and frequency KW KW RPM Volts Hz Amps Amps 1500 415 50 1500 415 50 1500 415 50 1500 415 50 1500 415 50 5 7.5 1.1 0.75 1.1 OUTDOOR INDOOR INDOOR INDOOR INDOOR (Nos.) Units CHILLER 2 H2 COMP. 2 ELECTRO. PUMP 2

DOC NO.
ANEPL/FDQC/16.5/3.2/DOC/012

REVISION - 0 DATE : 01/03/2007

INDIA

FEED WATER O2 LYE PUMP H2 LYE PUMP PUMP 2 2 2

VAC. PUMP 1

SQ. CAGE SQ. CAGE SQ. CAGE SQ. CAGE SQ. CAGE SQ. CAGE INDU. MOTOR INDU. MOTOR INDU. MOTOR INDU. MOTOR INDU. MOTOR INDU. MOTOR

SQ. CAGE INDU. MOTOR

INDOOR

INDOOR

CONTINUOUS CONTINUOUS CONTINUOUS CONTINUOUS CONTINUOUS CONTINUOUS

CONTINUOUS

1.1

1.1

1500 415 50

1500 415 50

SHEET 2 OF 10

GEA ENERGY SYSTEM (INDIA) LTD. POWER PROJECTS DIVISION VIJAYWADA TPS, STAGE IV, UNIT - 7, 1 X 500 MW SPECIFICATION FOR AC & DC MOTORS GID-064-EL-SA-2801
ANNEXURE 1 MOTOR DATA SHEET
i) Full Load ii) 3/4 Load iii) 1/2 Load 3.00 3.01 3.02 3.03 PERFORMANCE Method of starting Starting Current at rated voltage i) Starting torque at rated voltage ii) Pull-out torque at rated voltage 3.04 Starting time at 80% 100% for fans and 90% 100% for mill motors : i) With load ii) Without load 3.05 Safe Stall time at 110% rated voltage : i) Hot Condition ii) Cold Condition iii) Safe stall time at 100% / 80% for fans & 100% 90% for Mill Motors 3.06 Thermal Time Constant i) Heating ii) Cooling 3.07 Starts i) Equally spread/Hour ii) Successive Cold iii) Successive hot Nos. Nos. Nos. Min. Min. Sec. Sec. Hot (Sec.) Cold (Sec.) Sec. Sec. % of FLC % of FLT % of FLT % % %

DOC NO.
ANEPL/FDQC/16.5/3.2/DOC/012

REVISION - 0 DATE : 01/03/2007

INDIA

SHEET 3 OF 10

GEA ENERGY SYSTEM (INDIA) LTD. POWER PROJECTS DIVISION VIJAYWADA TPS, STAGE IV, UNIT - 7, 1 X 500 MW SPECIFICATION FOR AC & DC MOTORS GID-064-EL-SA-2801
ANNEXURE 1 MOTOR DATA SHEET
3.08 4.00 4.01 4.02 4.03 4.04 4.05 4.06 4.07 4.08 Permissive running time at full load at minimum allowable voltage CONSTRUCTION Degree of Protection of enclosure Method of cooling Insulation class Temperature rise over 50 deg. ambient (bt resistance) Tropicalised Mica with epoxy treatment for insulation Winding connection Bearing i) make ii) Type iii) Recommended lubricant 4.09 Motor Terminal Box i) Type, Phase segregated ii) Location as seen from NDE iii) Fault withstand a) Current b) Time iv) Cable lugs and Glands furnished v) Type and Range/Size of cable 5.00 ACCESSORIES KA Sec. Yes/No Yes/No DE/NDE Deg.C Yes/No Yes/No SELF F SELF F SELF F SELF F SELF F Min.

DOC NO.
ANEPL/FDQC/16.5/3.2/DOC/012

REVISION - 0 DATE : 01/03/2007

INDIA

SELF F

SELF F

SHEET 4 OF 10

GEA ENERGY SYSTEM (INDIA) LTD. POWER PROJECTS DIVISION VIJAYWADA TPS, STAGE IV, UNIT - 7, 1 X 500 MW SPECIFICATION FOR AC & DC MOTORS GID-064-EL-SA-2801
ANNEXURE 1 MOTOR DATA SHEET
5.01 Space Heaters i) No. x Watt (Total) ii) Volts, Phase, Frequency iii) Separate terminal box 5.02 Winding Temperature Detector i) Type ii) Nos. locations where provided iii) Resistance at 0 deg. 5.03 Bearing Temperature Indicator i) Type ii) Nos. furnished 5.04 Temperature indicators i) Type ii) Nos. Provided iii) Locations 5.05 Temperature Alarm Contacts i) Nos. Provided ii) Locations iii) Contact Rating 5.06 Flow Switch i) Nos. Provided ii) Locations iii) Contact Ratings NA NA NA NA NA NA NA NA NA NA NA NA NA NA NA Ohm NA NA NA NA NA NA NA NA NA NA Watts NA NA NA NA NA

DOC NO.
ANEPL/FDQC/16.5/3.2/DOC/012

REVISION - 0 DATE : 01/03/2007

INDIA

NA

NA

NA

NA

NA

NA

NA

NA

NA

NA

NA

NA

SHEET 5 OF 10

GEA ENERGY SYSTEM (INDIA) LTD. POWER PROJECTS DIVISION VIJAYWADA TPS, STAGE IV, UNIT - 7, 1 X 500 MW SPECIFICATION FOR AC & DC MOTORS GID-064-EL-SA-2801
ANNEXURE 1 MOTOR DATA SHEET
5.07 Current Transformer for Differential Protection i) Nos. Provided ii) Current Ratio iii) Class of accuracy iv) Dimensional Drawing 5.08 Accessory Terminal Box i) Nos. Provided ii) Cable Glands/lugs furnished iii) Type and Range/size of cable 6.00 6.01 GROUNDING Nos. of grounding pads provided i) On Motor Body ii) On Terminal Box 7.00 7.01 7.02 MISCELLANEOUS Type of Mounting Oveall Dimensions i) Length ii) Breadth iii) Height 7.03 Moment of Inertia i) Driven Equipment ii) Rotor iii) Total Kg-sq.mt Kg-sq.mt Kg-sq.mt mm mm mm NA NA NA NA NA NA NA NA NA NA

DOC NO.
ANEPL/FDQC/16.5/3.2/DOC/012

REVISION - 0 DATE : 01/03/2007

INDIA

NA

NA

NA

NA

SHEET 6 OF 10

GEA ENERGY SYSTEM (INDIA) LTD. POWER PROJECTS DIVISION VIJAYWADA TPS, STAGE IV, UNIT - 7, 1 X 500 MW SPECIFICATION FOR AC & DC MOTORS GID-064-EL-SA-2801
ANNEXURE 1 MOTOR DATA SHEET
7.04 Weight i) Stator with winding ii) Rotor (with winding) iii) Total iv) Copper used in motor v) Base plate vi) Cooler 7.05 Cooling Water System (if provided) i) Water Temperature a) Inlet b) Outlet ii) Water Pressure required iii) Air Temperature 7.06 7.07 7.08 7.09 Direction of rotation viewed from NDE Method of couplin with driven equipment Sealing arrangement for bearing Details of painting Details of extra precautions taken in motor design to meet 150% of normal voltage during high speed bus transfer Special features if any Total guaranteed losses comprising iron loss, friction wind age and stray Losses Break up Iron Loss Kw Kw NA NA NA NA NA Deg. C Deg. C kg/Sq.mm Deg. C CW OR CCW CW OR CCW CW OR CCW CW OR CCW CW OR CCW Kg Kg Kg Kg Kg Kg NA NA NA NA NA

DOC NO.
ANEPL/FDQC/16.5/3.2/DOC/012

REVISION - 0 DATE : 01/03/2007

INDIA

NA

NA

CW OR CCW

CW OR CCW

7.10

7.11 7.12

NA

NA

SHEET 7 OF 10

GEA ENERGY SYSTEM (INDIA) LTD. POWER PROJECTS DIVISION VIJAYWADA TPS, STAGE IV, UNIT - 7, 1 X 500 MW SPECIFICATION FOR AC & DC MOTORS GID-064-EL-SA-2801
ANNEXURE 1 MOTOR DATA SHEET
Cu Loss Friction wind age 7 stray Losses 7.13 CT's Differntial protection (For motors more than 1000 KW) i) Type & Make ii0 Ratio 7 Accuracy Class iii0 Class of Insulation iv) Rated voltage and frequency v) Knee point voltage vi) Applicable standards vii) Dimension of CT's viii) Separate terminal box CT's provided ix) If yes, Dimension of Box 7.14 Motor Bearings i) Permissible temperature rise ii) Design ambient temperature assumed for above iii) Manufacturers reference no. of catalogues attached 7.15 Motor bearing lubrication system whether self lubricated or forced lubricated Forced lubrication (if provided) Whether this is compatible with forced oil. Lubrication system of driven equipment, if so, furnish the details Yes/No NO NO NO NO NO Deg. C Deg. C Yes/No Kw Kw NA NA NA NA NA

DOC NO.
ANEPL/FDQC/16.5/3.2/DOC/012

REVISION - 0 DATE : 01/03/2007

INDIA

NA

NA

7.16

NO

NO

SHEET 8 OF 10

GEA ENERGY SYSTEM (INDIA) LTD. POWER PROJECTS DIVISION VIJAYWADA TPS, STAGE IV, UNIT - 7, 1 X 500 MW SPECIFICATION FOR AC & DC MOTORS GID-064-EL-SA-2801
ANNEXURE 1 MOTOR DATA SHEET
i) Type & Make & Specification of Oil ii) Flow Rate iii) Pressure iv) Quantity of lube oil pump sets provided for each motor No. v) Location of comtrol panel provided for forced oil lubrication system for each motor vi) Make, type 7 Name plate particulars of lube oil pumps and 415 volts 3 phase 50 hz motors vii) Coolers - material viii) Filters - Make & Type 7.17 Quick disconnecting type terminal connection provided if provided then i) Make and Type ii) Operating Voltage iii) Current Rating iv) Oil filled / Air insulated v) Refernce no of manufacturers catalogues attached 7.18 Stator core temperature detectors i) Make and Type ii) No & Locations Where iii) Resistance at 0 deg. iv) Reference Literature attached Ohm Yes/No NA NA NA NA NA Yes/No NO NO NO NO NO Liters/Sec Kg/Sq.mm

DOC NO.
ANEPL/FDQC/16.5/3.2/DOC/012

REVISION - 0 DATE : 01/03/2007

INDIA

NO

NO

NA

NA

SHEET 9 OF 10

GEA ENERGY SYSTEM (INDIA) LTD. POWER PROJECTS DIVISION VIJAYWADA TPS, STAGE IV, UNIT - 7, 1 X 500 MW SPECIFICATION FOR AC & DC MOTORS GID-064-EL-SA-2801
ANNEXURE 1 MOTOR DATA SHEET
7.19 7.20 Permissible vibrations limits Vibrations Detectors Provided i) Make and Type ii) No. and Locations iii) Reference catalogues attached 7.21 7.22 7.23 Vibration recorder provided Magnetizing current of motor at rayed voltage & frequency Motor Reactance i) Sub transient reactance ii) Transient reactance iii) Steady state reactance 7.24 7.25 7.26 7.27 7.28 Surge impedance per phase Capacitance per phase to earth Winding resistance per phase at 20 deg. C Winding resistance between terminals at 20 deg. C Shaft Orientation Horizontal/Vertical/Hollow Vertical 7.29 7.30 7.31 8.00 Whether half coupling required Whether bed plate required Whether rails required CHARACTERISTIC CURVES FOR MOTOR ATTACHED i) Speed Vs current at rated voltage Yes/No Yes/No Yes/No Yes/No HORIZONTAL HORIZONTAL HORIZONTAL HORIZONTAL HORIZONTAL Yes/No Yes/No Amps Ohms/Phase PU PU PU Ohms/Phase microfarads Ohms NO NO NO NO NO microns Yes/No NO NO NO NO NO

DOC NO.
ANEPL/FDQC/16.5/3.2/DOC/012

REVISION - 0 DATE : 01/03/2007

INDIA

NO

NO

NO

NO

HORIZONTAL

HORIZONTAL

SHEET 10 OF 10

GEA ENERGY SYSTEM (INDIA) LTD. POWER PROJECTS DIVISION VIJAYWADA TPS, STAGE IV, UNIT - 7, 1 X 500 MW SPECIFICATION FOR AC & DC MOTORS GID-064-EL-SA-2801
ANNEXURE 1 MOTOR DATA SHEET
ii) Speed Vs Torque at 110%, 100%, 90% & 80% of rated voltage iii) Thermal withstand curve for hot and cold condition iv) efficiency Vs. Load v) P.F. Vs. load vi) Current Vs. Time vii) Negative phase sequence Yes/No Yes/No Yes/No Yes/No Yes/No Yes/No

DOC NO.
ANEPL/FDQC/16.5/3.2/DOC/012

REVISION - 0 DATE : 01/03/2007

INDIA