Wind Mill Application

10th Jan 2011

Agenda

Basics of Wind Mill Application


Construction & Working

Single Line Diagram Switchgear in Wind Mill


Specifications & Special Requirements

L&T Switchgear in Wind Mill


Offering

EAOC / SDDC

Basics of Wind Mill Application

EAOC / SDDC

Basics of Wind Mill Application


Types of Wind Mills

EAOC / SDDC

Basics of Wind Mill Application


Main Component of Wind Mill

250kW, 600kW, 1.0MW, 1.2MW, 1.5MW


EAOC / SDDC

Basics of Wind Mill Application


Main Component of Wind Mill

EAOC / SDDC

Basics of Wind Mill Application


Main Component of Wind Mill

EAOC / SDDC

Basics of Wind Mill Application


Working of Wind Mill

EAOC / SDDC

Basics of Wind Mill Application


Working of Wind Mill

EAOC / SDDC

Basics of Wind Mill Application


Working of Wind Mill

Soft Starting

EAOC / SDDC

10

Basics of Wind Mill Application


Working of Wind Mill

EAOC / SDDC

11

Basics of Wind Mill Application


Working of Wind Mill

EAOC / SDDC

12

Single Line Diagram

13

EAOC / SDDC

Single Line Diagram


Single Line Diagram

EAOC / SDDC

14

Switchgear in Wind Mill

15

EAOC / SDDC

Switchgear in Wind Mill Specifications


ACBs MCCBs Power Contactors Control Contactors Capacitor Duty Contactors MPCBs Capacitors MCBs Fuses Cables
16

690V, 800-2000A, 3P EF 415/690V, 250/630/1000A 415/690V, 700/800A Control Voltage, 9A (3NO+1NC) Control Voltage, 30/50A Control Voltage, 1.6/6.3/10/25A 690V, 25kVAr, 12.5kVAr 415/690V, 3-P/2-P/1-P, 2/4/6/10/16A 500/690V, 160A Base, 5A Hallogen Free
EAOC / SDDC

Switchgear requirement
A typical 250kW Wind Mill (for dual winding AC Generator)
Product MCCB Power Contactor Control Contactor Capacitor Duty Contactor Fuse MCB ( 2 Pole ) MCB ( 1 Pole ) MPCB
17

Rating 630A 250A 700A 250A 9A 30KVAR 50kVAR 5A 4/10/16A 2/6/10A 1.6/6.3/10/25

Qty. 1 no. 1 no. 2 nos 1 no. 9 nos 3 nos. 4 nos. 3 nos. 4 nos. 5 nos. 7 nos.
EAOC / SDDC

Switchgear in Wind Mill

Special Requirements
Maintenance Free Harsh Climatic Conditions (-5 Deg C to +70 Deg C) Impact and Vibrations 690V Operating Voltage (mostly above 600kW)

EAOC / SDDC

18

L&T Switchgear in Wind Mill

19

EAOC / SDDC

Wind Mill Manufacturers

Name of Manufacturer
Enercon (India ) Ltd Global Wind Power Leitner Sriram Pioneer Wincon Regen Powertech RRB Energy Siva Wind Turbine Southern Wind Farms Suzlon Energy Vestas Winwind

Capacity
800 kW 750 kW 1350 kW 250 kW 1500 kW 600 kW 250 kW 225 kW 600 kW/1250 kW/1500 kW 1600 kW 1000 kW

qty
500 50 40 100 250 300 25 100 1000 40 15

EAOC / SDDC

20

Market

Mind set : Most of them have collaboration with the European Wind Mill Players Control panel drawing (SLD) based on European counter part inputs Existing switchgear are proven & hesitation to change ABB is the range mostly preferred by them

Good points : Indian Companies are coming by their own Willing to try other makes - alternate product / price point Also prefer L&T - Local make /Easy availability /Service network

21

EAOC / SDDC

L&T Switchgear in Wind Mill

Offering
ACBs MCCBs Power Contactors Capacitors MCBs Capacitor Duty Contactors : C-POWER / U-POWER : d-sine range for 690V ac MCCB range for 415V ac : 3 Pole MNX : Heavy Duty Gas Filled : 2 Pole / 1 pole : MPX

EAOC / SDDC

22

L&T switchgear- ACB in Wind Mill

For a 1500kW wind turbine


Specification: 2000A 3P EF (Motor/closing 230V ac & SR/UV 24V dc) with Microprocessor based LSI protection What ABB supplies? 2000A E2N @690V ac 3P EF with PR121/P (LSI) Product to offer: Choice: C-POWER U-POWER Omega
23

2000A H (with690V arc chute) 3P EF with SR18 2000A Fr-1 S 3P EF with UN-RS1.5I 2000A Fr-1 S 3P EF with MTX2.5
EAOC / SDDC

L&Ts ACB range for 690Vac application

C-POWER C/H type with 690V arc chutes Rating Pole Breaking Capacity ( Icu) Ics as % of Icu Icw 800A to 1600A 3 & 4 Pole C = 35kA H = 50kA 100% C=35kA H=50kA 2000/2500A 3 & 4 Pole C = 40kA H = 65kA 100% C = 40kA H = 65kA 3200/4000A 3 & 4 Pole C=65kA H=85kA 100% C=65kA H=85kA

24

EAOC / SDDC

L&Ts ACB range for 690Vac application

U-POWER Rating Pole Breaking Capacity ( Icu) Ics as % of Icu Icw 800A to 1600A 3 & 4 Pole N = 42kA S = 50kA 100% N = 42kA S = 50kA 2000/2500A 3 & 4 Pole S = 50kA H = 65kA 100% S = 50kA H = 65kA 3200/4000A 3 & 4 Pole H=65kA V=85kA 100% H=65kA V=85kA

25

EAOC / SDDC

L&Ts ACB range for DC application

C-POWER H type with 690V arc chutes upto 4000A can be offered for DC application w/o protection device U-POWER Range up to 6300A w/o protection device.

26

EAOC / SDDC

Wind Energy
Total installed capacity (17000 MW) Potential 45000 MW Potential 82000 MW if off Shore is also added Major Installations - TN-AP-KAR-GUJ-MAH-RAJMP India at no 5th after Germany (1), Spain (2), USA(3), China(4), Denmark(6) Installation Cost - 4.5 to 5 Cr per MW Potential for Switchgear 2.5 Lacs/1.5 MW (750 Cr This is total potential considering 45000 MW Installation. If this gets executed in next 10 years, it means, 75 Crore will be current year potential)
EAOC / SDDC

Major Manufacturers & Rating


Chiranjjeevi Wind Energy (Cmb)Enercon(Daman) Essar Wind Power(Mum) Gamesha Wind Turbines(Chen)GE India (Bgr) Global Wind Power(Mum) Kenersys India (Pune) Leitner Shriram (Chen) Pioneer Wincon (Chen) Regen Powertech (Chen) RRB Energy (Chen) Shri Ram EPC (Che) Shiva Wind Turbine (Erode) Southern Wind Farm (Che) Suzlon (Pune) Vestas (Chennai) Win Wind (Chennai) Inox (Noida) 250 KW 800 KW 1500 KW 850 KW 1500 KW 750 KW 2000 KW 1350/1500KW 250 KW (750 KW Under testing) 1500 KW 500/600 KW (ut) 250 KW 250 KW 225 KW 1500/2100 KW (1250 KW-UT) 1650 KW 1000 KW 2000 KW (Under Testing) EAOC / SDDC

Thank You!!!