True North
Certificate of Concentration
MORGAN SCHAFFER
Transformers - The Inside View
5110 de Courtrai Avenue, Montreal, Quebec, Canada H3W 1A7 Tel.: +514.739.1967 Fax: +514.739.0434 Web: www.morganschaffer.com

Syringe S/N:

Lot No.:

Date Filled:

Prepared by:

QC Approved:

H2 O2 N2 CH4 CO

COMPONENT* CONCENTRATION (PPM) (Hydrogen) 88 3% 11163 3% (Oxygen) 40368 3% (Nitrogen) 96 3% (Methane) 89 3% (Carbon Monoxide)

CO2 C2H4 C2H6 C2H2

COMPONENT* (Carbon Dioxide) (Ethylene) (Ethane) (Acetylene)

CONCENTRATION (PPM) 123 5% 90 3% 92 4% 84 4%

(*) Milliliters of gas at 273K and 760 torr per cubic meter of oil. Concentrations are determined by the method of preparation and are verified by laboratory analysis.

Each True North DGA Sample is carefully prepared from a bulk standard. A Certificate of Concentration is delivered with each sample as a guarantee of accuracy and traceability. The Certificate of Concentration contains the actual concentrations of the different gases found in the sample. Once the sample is analyzed, the reported results should correspond to the values found on the Certificate of Concentration. If the results are outside the laboratory accepted standard deviation, procedures and calibrations are not being followed and should be verified.
OTHER MS
SEVICES
APPLICATION Calibration, verification and trouble shooting of laboratory DGA (Dissolved Gas Analysis) systems. PREPARATION METHOD NIST traceable gas mixture dissolved in degassed oil in accordance with principles outlined in ASTM Method D3612-01, Annex A2 (2001) and IEC publication 60567, clause 6.2 (1992). DESCRIPTION 30cc glass, gas tight syringe containing 9 gases dissolved in dielectric fluid. Syringe has a 3 way valve with Luer Lock fitting. A unique identification number for each True North sample can be found on the Certificate of Concentration. DISSOLVED GAS QUANTITIES Stated in each sample Certificate of Concentration. Typical values: 100 ppm for fault gases (H2, CH4, CO, CO2, C2H4, C2H6, C2H2). Balance gas industrial air. OIL TYPE New Voltesso 35 dielectric insulating fluid. ENVIRONMENT Storage: 15C to 30C; sample must be kept in its box. Use: 20C to 25C STABILITY Bulk storage prior to shipping has a shelf life of at least 12 months. Shelf life of sample: 1 month from date of delivery. PHYSICAL 10 cm (4) high 10 cm (4) wide 30 cm (12) deep 0.5 kg (1 lb) WARRANTY AND SUPPORT Morgan Schaffers True North DGA Oil Standard is backed by a full return policy on unused samples. Technical support is provided free of charge to all True North users. True North and other Morgan Schaffer products and services are available through Morgan Schaffers worldwide network of authorized distributors and agents.
NOTE: Continuing research and improvements may result in specification or appearance changes at any time.

HIGH SENSITIVITY DGA MOISTURE


CONTENT

PCB ANALYSIS STANDARD


OIL TESTS

FURAN ANALYSIS INHIBITOR


CONTENT

MORGAN SCHAFFER
Transformers - The Inside View

5110 de Courtrai Avenue Montreal, Quebec Canada H3W 1A7

Tel.: +514.739.1967 Fax: +514.739.0434 E-mail: sales@morganschaffer.com

VISIT OUR WEBSITE AT: www.morganschaffer.com

Copyright 2003 Morgan Schaffer Inc. All rights reserved. - The MS Morgan Schaffer Transformers - The Inside View logo and True North are trademarks of Morgan Schaffer Inc.

MORGAN SCHAFFER
Transformers - The Inside View

DGA Oil Standard

True North
True North is a dissolved gas-in-oil standard that can be used to validate and verify laboratory equipment and operations YOUR GUIDE TO ACCURATE RESULTS Dissolved Gas Analysis (DGA) is the most important test that you can perform on your transformer. It is the only test that can determine the operating status of oil-filled electrical equipment. True North DGA Oil Standards enable oil testing laboratories to verify, standardize and calibrate their equipment. Transformer owners can also use True North to evaluate laboratory performance to ensure they are obtaining accurate results. TRUE NORTH LEADS THE WAY True North is the only way to verify total analytical system performance. It provides a common base for calibration of all DGA systems, independently of the gas extraction method, gas detection technique or equipment used. True North can be used as a common reference which will allow data trending using results from different laboratories. Contained in an industry standard 30cc syringe,True North can be easily shipped using IATA approved boxes. TRUE NORTH IS EASY TO USE Industry accepted glass syringes prevent loss of dissolved gases to the atmosphere or contamination by atmospheric components. Individual cardboard packaging prevents generation of fault gases by exposure to light. IATA accepted outer packaging guarantees timely and trouble free shipping of oil standards by air, worldwide. Morgan Schaffer's preparation and quality control processes are in accordance with the principles outlined in IEC 60567 and ASTM-D3612 for the preparation of oil standards. And customers can keep the syringes after use.

MORGAN SCHAFFER a pioneer in the development of DGA, has been providing the electrical industry, worldwide, with reliable and accurate results for over 35 years.