Series V Engineering Data

VFL MODELS
1/2 FPT Vent

Fluid In

Fluid Out

H
Access
Door

1 Make-up
Overflow

Spray Pump
2 Drain

4-1 1/4

L
Side Elevation: Models VFL-012 to 048

End Elevation: Models VFL-012 to 048

1/2 FPT Vent


Fluid In

Fluid Out

Access
Door

2 Make-up
Overflow

2 Drain
7-10 1/2

End Elevation: Models VFL-072 to 096

Side Elevation: Models VFL-072 to 096

NOTES:
1. Nominal tons of cooling represents the capability to cool 3 USGPM
of water from a 95F entering water temperature to an 85F leaving
water temperature at a 78F entering wet-bulb temperature.
2. Fan horsepower is at 0 external static pressure.
3. Operating weight is for the unit with the water level in the cold water
basin at the overflow and a full coil.
4. Standard coil connections are beveled for welding.

5. The number and location of coil connections will vary with design flow
and coil arrangement.
6. If discharge hoods with positive closure damper are furnished, see
page C91 for added weight and height. Fan motor horsepower may
increase; consult selection software for verification.
7. All units ship in one piece.
8. VFL-012 to 048, the riser pipe diameter is 3. For VFL-072 to 096, the
riser pipe diameter is 4.

Do not use for construction. Refer to factory certified dimensions. This catalog includes data current at
the time of publication, which should be reconfirmed at the time of purchase.
C83

Q U E S T I O N S ? C A L L 4 1 0 . 7 9 9 . 6 2 0 0 O R V I S I T W W W. B A LT I M O R E A I R C O I L . C O M

NOTE: Up-to-date engineering data, free product selection software, and more can be found at www.BaltimoreAircoil.com.

Motor HP
Model
Number

Weights (lbs)

Dimensions

Connections
Overflow

Spray
Pump
(USGPM)

Internal Coil
Volume (gal)

45

18

45

18

1-11

45

25

6-4

1-11

45

25

7-1

6-10

2-8

45

32

7-1

6-10

2-8

45

32

7-1

6-10

2-8

45

39

2,330

7-1

6-10

2-8

45

39

4,610

3,120

11-0

6-4

1-10

94

47

15,180

4,610

3,120

11-0

6-4

1-10

94

61

1/2

17,380

5,130

3,150

11-0

6-10

2-7

94

61

1/2

14,990

5,750

3,960

11-0

7-4

3-3

94

75

7.5

1/2

17,160

5,750

3,960

11-0

7-4

3-3

94

75

Nominal
Tons[1]

Fan[2]

VFL-012-02F

VFL-012-02G

VFL-012-12F
VFL-012-12H

Pump

Airflow
(CFM)

Operating[3]

Shipping

Coil[4,5]

1/3

8,050

2,560

1,880

7-1

5-5

1-3

1/3

9,220

2,560

1,180

7-1

5-5

1-3

1/3

7,870

2,810

2,090

7-1

6-4

1/3

10,680

2,810

2,090

7-1

VFL-012-22F

1/3

7,750

3,140

2,330

VFL-012-22H

11

1/3

10,510

3,140

2,330

VFL-012-32G

12

1/3

8,760

3,140

2,330

VFL-012-32H

14

1/3

10,380

3,140

VFL-024-12H

17

1/2

15,430

VFL-024-22H

21

1/2

VFL-024-22J

24

7.5

VFL-024-32H

26

VFL-024-32J

30

VFL-036-22K

35

10

23,580

7,070

4,690

15-0

7-0

2-10

142

90

VFL-036-22L

40

15

26,990

7,070

4,690

15-0

7-0

2-10

142

90

VFL-036-22M

46

20

29,710

7,070

4,690

15-0

7-0

2-10

142

90

VFL-036-31M

49

20

29,340

7,950

5,330

15-0

8-0

3-7

142

111

VFL-036-32K

43

10

23,290

7,950

5,330

15-0

8-0

3-7

142

111

VFL-036-32L

50

15

26,660

7,950

5,330

15-0

8-0

3-7

142

111

VFL-036-32M

56

20

29,340

7,950

5,330

15-0

8-0

3-7

142

111

VFL-048-22L

43

15

1 1/2

29,150

8,905

5,616

18-0

6-11

2-10

284

119

VFL-048-31L

46

15

1 1/2

28,790

9,320

6,480

18-0

7-9

3-7

284

148

VFL-048-31M

52

20

1 1/2

31,680

9,320

6,480

18-0

7-9

3-7

284

148

VFL-048-41L

49

15

1 1/2

28,490

10,350

7,230

18-0

8-5

4-4

284

177

VFL-072-22N

69

25

1 1/2

45,390

12,835

8,755

15-0

7-1

2-10

284

180

VFL-072-22O

75

30

1 1/2

48,240

12,835

8,755

15-0

7-1

2-10

284

180

VFL-072-31N

75

25

1 1/2

44,830

14,470

9,920

15-0

7-9

3-7

284

223

VFL-072-31O

81

30

1 1/2

47,640

14,470

9,920

15-0

8-0

3-7

284

223

VFL-072-31P

92

40

1 1/2

52,430

14,470

9,920

15-0

8-0

3-7

284

223

VFL-072-41N

79

25

1 1/2

44,370

15,870

10,950

15-0

8-5

4-4

284

265

VFL-072-41O

86

30

1 1/2

47,150

15,870

10,950

15-0

8-8

4-4

284

265

VFL-072-41P

97

40

1 1/2

51,900

15,870

10,950

15-0

8-9

4-4

284

265

VFL-096-41N

86

25

50,920

18,940

12,960

18-0

8-5

4-4

384

347

VFL-096-41O

94

30

54,110

18,940

12,960

18-0

8-5

4-4

384

347

VFL-096-41P

108

40

59,560

18,940

12,960

18-0

8-5

4-4

384

347

PRODUCT & APPLICATION HANDBOOK 2012

C84

Series V Engineering Data


1/2 FPT Vent
Fluid In

VF1 MODELS
F

Fluid out

H
1 Make-up

End Elevation: Models VF1-009 to 036

Side Elevation: Models VF1-009 to 036

2 Overflow
A
2 Drain

M
L

3 11-1/2

1/2 FPT Vent


Fluid In

End Elevation: Models VF1-048

Fluid Out

H
1 Make-up

Side Elevation: Models VF1-048

Access

3 Overflow
2 Drain

M
L

4- 8 5/8

1/2 MPT Vent

Fluid In

Fluid Out
F

End Elevation: Models VF1-072

Side Elevation: Models VF1-072

Access
2 Make-up
A

3 Overflow

7 - 10 3/8

NOTES FOR OPPOSITE TABLE:


1. Nominal tons of cooling represents the capability to cool 3 USGPM
of water from a 95F entering water temperature to an 85F leaving
water temperature at a 78F entering wet-bulb temperature.

5. Standard coil connections are beveled for welding.

2. Fan horsepower is at 0 external static pressure.


3. Operating weight is for the unit with the water level in the cold water
basin at the overflow and a full coil.

7. If discharge hoods with positive closure damper are furnished, see


page C91 for added weight and height. Fan motor horsepower may
increase; consult selection software for verification.

4. Units marked with an asterisk ship in one piece. The coil section is the
heaviest section.

8. For VF1-009 to 048, the riser pipe diameter is 3. For VF1-072 the
riser pipe diameter is 4.

6. The number and location of coil connections will vary with design flow
and coil arrangement.

Do not use for construction. Refer to factory certified dimensions. This catalog includes data current at
the time of publication, which should be reconfirmed at the time of purchase.
C85

Q U E S T I O N S ? C A L L 4 1 0 . 7 9 9 . 6 2 0 0 O R V I S I T W W W. B A LT I M O R E A I R C O I L . C O M

Motor HP
Model
Number
VF1-009-12E
VF1-009-12F
VF1-009-12G
VF1-009-22F
VF1-009-22G
VF1-009-32G
VF1-009-42G
VF1-018-12F
VF1-018-12G
VF1-018-12H
VF1-018-22H
VF1-018-22J
VF1-018-32G
VF1-018-32H
VF1-018-32J
VF1-018-42H
VF1-018-42J
VF1-027-22H
VF1-027-22J
VF1-027-22K
VF1-027-32H
VF1-027-32J
VF1-027-32K
VF1-027-42H
VF1-027-42J
VF1-027-42K
VF1-036-21L
VF1-036-22J
VF1-036-22K
VF1-036-22L
VF1-036-31L
VF1-036-32J
VF1-036-41L
VF1-036-51L
VF1-048-21L
VF1-048-21M
VF1-048-31M
VF1-048-31N
VF1-048-41M
VF1-048-41N
VF1-072-21M
VF1-072-21N
VF1-072-21O
VF1-072-31M
VF1-072-31N
VF1-072-31O
VF1-072-41M
VF1-072-41N
VF1-072-41O

Nominal
Tons[1]

Fan[2]

4
5
5
6
7
8
9
9
11
14
17
20
16
19
22
21
24
24
28
32
26
31
35
28
33
37
41
35
39
47
44
37
47
49
48
55
59
65
63
70
62
69
75
67
74
81
72
80
86

1.5
2
3
2
3
3
3
2
3
5
5
7.5
3
5
7.5
5
7.5
5
7.5
10
5
7.5
10
5
7.5
10
15
7.5
10
15
15
7.5
15
15
15
20
20
25
20
25
20
25
30
20
25
30
20
25
30

Pump

1/3

1/2

3/4

1 1/2

Weights (lbs)

Dimensions

Airflow
(CFM)

Operating[3]

Shipping

Heaviest
Section[4]

4,510
4,970
5,690
4,890
5,590
5,520
5,470
8,050
9,220
10,930
10,750
12,310
8,960
10,620
12,150
10,510
12,030
14,060
16,090
17,710
13,880
15,890
17,490
13,740
15,730
17,310
24,870
19,740
21,730
24,870
24,560
19,490
24,310
24,100
32,520
35,790
35,340
38,070
34,980
37,690
45,990
49,540
52,650
45,420
48,930
51,990
44,960
48,430
51,460

1,875
1,875
1,875
2,075
2,075
2,295
2,495
2,955
2,955
2,955
3,260
3,260
3,660
3,660
3,660
4,010
4,010
4,860
4,860
4,860
5,440
5,440
5,440
5,970
5,970
5,970
6,280
6,280
6,280
6,280
7,020
7,020
7,710
8,390
10,230
10,230
11,390
11,390
12,690
12,690
15,670
15,670
15,670
17,380
17,380
17,380
18,000
18,000
18,000

1,625
1,625
1,625
1,785
1,785
1,965
2,125
2,415
2,415
2,415
2,640
2,640
2,940
2,940
2,940
3,190
3,190
3,750
3,750
3,750
4,180
4,180
4,180
4,570
4,570
4,570
4,760
4,760
4,760
4,760
5,310
5,310
5,810
6,310
7,870
7,870
8,460
8,460
9,320
9,320
10,720
10,720
10,720
12,050
12,050
12,050
12,480
12,480
12,480

1,460*
1,460*
1,460*
1,000
1,000
1,180
1,340
2,415*
2,415*
2,415*
1,720
1,720
2,010
2,010
2,010
2,260
2,260
2,470
2,470
2,470
2,850
2,850
2,850
3,240
3,240
3,240
3,200
3,200
3,200
3,200
3,720
3,720
4,220
4,720
4,920
4,920
5,930
5,930
6,600
6,600
6,580
6,580
6,580
7,950
7,950
7,950
9,320
9,320
9,320

3-0

6-0

9-0

12-0

12-0

11-8

Connections

7-4
7-4
7-4
8-1
8-1
8-9
9-6
7-4
7-4
7-4
8-1
8-1
8-9
8-9
8-9
9-6
9-6
8-4
8-4
8-4
9-1
9-1
9-1
9-10
9-10
9-10
8-4
8-4
8-4
8-4
9-1
9-1
9-10
10-7
10-0
10-0
10-9
10-9
11-7
11-7
11-4
11-4
11-4
12-2
12-2
12-2
12-11
12-11
12-11

1-11
1-11
1-11
2-8
2-8
3-4
4-1
1-11
1-11
1-11
2-8
2-8
3-3
3-3
3-3
4-0
4-0
2-10
2-10
2-10
3-7
3-7
3-7
4-4
4-4
4-4
2-10
2-10
2-10
2-10
3-7
3-7
4-4
4-4
2-10
2-10
3-7
3-7
4-4
4-4
2-10
2-10
2-10
3-7
3-7
3-7
4-4
4-4
4-4

Coil[5,6]

Overflow

Spray
Pump
(USGPM)

3-9

35

3-9

75

3-9

115

3-9

150

5-5

220

6-9

305

Internal
Coil Volume
(gal)
20
20
20
26
26
31
36
38
38
38
49
49
60
60
60
71
71
72
72
72
89
89
89
106
106
106
95
95
95
95
118
118
140
163
137
137
170
170
203
203
190
190
190
235
235
235
281
281
281

NOTE: Up-to-date engineering data, free product selection software, and more can be found at www.BaltimoreAircoil.com.

PRODUCT & APPLICATION HANDBOOK 2012

C86

Series V Engineering Data


VF1 MODELS
1/2 FPT Vent
Fluid In
F

Fluid Out

H
2 Make-up
3 Overflow

A
M

7 10-3/8

L
Side Elevation: Models VF1-096, 144N, & 144

End Elevation: Models VF1-096 to 144N, & VF1-192 to 288N

1/2 FPT Vent

Fluid In
Fluid Out

F
H

2 Make-Up
3 Overflow
2 Drain

11 10

End Elevation: Models VF1-144, 216, & VF1-288 to 432

Side Elevation: Models VF1-216

24-0 1/2
36-1 1/4

11-11 3/4

18-0 1/8

L
Side Elevation: Models VF1-192 & 288

L
Side Elevation: Models VF1-432

NOTE: Up-to-date engineering data, free product selection software, and more can be found at www.BaltimoreAircoil.com.

C87

Q U E S T I O N S ? C A L L 4 1 0 . 7 9 9 . 6 2 0 0 O R V I S I T W W W. B A LT I M O R E A I R C O I L . C O M

Motor HP
Model
Number
VF1-096-31O
VF1-096-31P
VF1-096-31Q
VF1-096-41O
VF1-096-41P
VF1-096-41Q
VF1-096-51P
VF1-096-51Q
VF1-144N-21P
VF1-144N-21Q
VF1-144N-21R
VF1-144N-31P
VF1-144N-31Q
VF1-144N-31R
VF1-144N-41P
VF1-144N-41Q
VF1-144N-41R
VF1-192-31O
VF1-192-31P
VF1-192-31Q
VF1-192-41O
VF1-192-41P
VF1-192-41Q
VF1-192-51P
VF1-192-51Q
VF1-288N-21P
VF1-288N-21Q
VF1-288N-21R
VF1-288N-31P
VF1-288N-31Q
VF1-288N-31R
VF1-288N-41P
VF1-288N-41Q
VF1-288N-41R

Nominal
Tons[1]

Fan[2]

81
93
102
87
99
109
104
114
113
127
139
122
136
148
130
144
157
163
185
205
174
198
219
207
228
226
253
277
244
271
295
260
288
313

30
40
50
30
40
50
40
50
40
50
60
40
50
60
40
50
60
60
80
100
60
80
100
80
100
80
100
120
80
100
120
80
100
120

Pump

10

Weights (lbs)

Dimensions

Airflow
(CFM)

Operating[3]

Shipping

Heaviest
Section[4]

53,540
58,930
63,480
52,990
58,320
62,830
57,820
62,290
67,490
72,700
77,250
66,640
71,790
76,290
65,960
71,060
75,510
106,150
116,830
125,850
105,060
115,640
124,570
114,640
123,490
135,080
145,510
154,630
133,400
143,700
152,700
132,030
142,230
151,140

19,385
19,385
19,385
21,345
21,345
21,345
23,305
23,305
25,610
25,610
25,610
28,480
28,480
28,480
31,560
31,560
31,560
38,900
38,900
38,900
42,780
42,780
42,780
46,660
46,660
51,260
51,260
51,260
57,080
57,080
57,080
63,220
63,220
63,220

12,795
12,795
12,795
14,215
14,215
14,215
14,855
14,855
16,430
16,430
16,430
18,490
18,490
18,490
20,750
20,750
20,750
25,570
25,570
25,570
28,360
28,360
28,360
29,780
29,780
32,750
32,750
32,750
36,950
36,950
36,950
40,520
40,520
40,520

8,460
8,460
8,460
9,880
9,880
9,880
10,520
10,520
10,390
10,390
10,390
12,570
12,570
12,570
14,750
14,750
14,750
8,460
8,460
8,460
9,880
9,880
9,880
10,520
10,520
11,970**
11,970**
11,970**
12,570
12,570
12,570
14,750
14,750
14,750

11-8

17-9

23-9

35-10

Connections

13-7
13-7
13-7
14-4
14-4
14-4
15-1
15-1
12-10
12-10
12-10
13-7
13-7
13-7
14-4
14-4
14-4
13-7
13-7
13-7
14-4
14-4
14-4
15-1
15-1
12-10
12-10
12-10
13-7
13-7
13-7
14-4
14-4
14-4

3-7
3-7
3-7
4-4
4-4
4-4
5-1
5-1
2-10
2-10
2-10
3-7
3-7
3-7
4-4
4-4
4-4
3-7
3-7
3-7
4-4
4-4
4-4
5-1
5-1
2-10
2-10
2-10
3-7
3-7
3-7
4-4
4-4
4-4

Coil[5,6]

Overflow

Spray
Pump
(USGPM)

8-2

400

8-2

610

8-2

800

8-2

1,220

Internal
Coil Volume
(gal)
296
296
296
353
353
353
411
411
356
356
356
443
443
443
529
529
529
592
592
592
706
706
706
822
822
712
712
712
886
886
886
1,058
1,058
1,058

NOTES:
1. Nominal tons of cooling represents the capability to cool 3 USGPM
of water from a 95F entering water temperature to an 85F leaving
water temperature at a 78F entering wet-bulb temperature.

5. Standard coil connections are beveled for welding.

2. Fan horsepower is at 0 external static pressure.


3. Operating weight is for the unit with the water level in the cold water
basin at the overflow and a full coil.

7. If discharge hoods with positive closure damper are furnished, see


page C91 for added weight and height. Fan motor horsepower may
increase; consult selection software for verification.

4. Unless marked with a double asterisk (**), the coil section is the
heaviest section.

8. For VF1-096 and 192, the riser pipe diameter is 4. For VF1-144N and
288N the riser pipe diameter is 6.

6. The number and location of coil connections will vary with design flow
and coil arrangement.

Do not use for construction. Refer to factory certified dimensions. This catalog includes data current at
the time of publication, which should be reconfirmed at the time of purchase.
PRODUCT & APPLICATION HANDBOOK 2012

C88

Series V Engineering Data


VF1 MODELS
Motor HP
Model
Number
VF1-144-21P
VF1-144-21Q
VF1-144-21R
VF1-144-31P
VF1-144-31Q
VF1-144-31R
VF1-144-41P
VF1-144-41Q
VF1-144-41R
VF1-216-21N
VF1-216-21O
VF1-216-21P
VF1-216-31N
VF1-216-31O
VF1-216-31P
VF1-216-41O
VF1-216-41P
VF1-216-41Q
VF1-288-21P
VF1-288-21Q
VF1-288-21R
VF1-288-31P
VF1-288-31Q
VF1-288-31R
VF1-288-41Q
VF1-288-41R
VF1-432-21N
VF1-432-21O
VF1-432-21P
VF1-432-31N
VF1-432-31O
VF1-432-31P
VF1-432-41O
VF1-432-41P
VF1-432-41Q

Nominal
Tons[1]

Fan[2]

116
129
141
127
140
153
137
151
164
172
188
217
185
202
231
215
245
271
232
259
282
254
281
305
299
325
343
376
434
371
404
462
430
490
543

40
50
60
40
50
60
40
50
60
50
60
80
50
60
80
60
80
100
80
100
120
80
100
120
100
120
100
120
160
100
120
160
120
160
200

Weights (lbs)

Pump

7.5

10

15

Dimensions

Airflow
(CFM)

Operating[3]

Shipping

Heaviest
Section[4]

81,320
87,600
93,080
80,300
86,500
91,920
79,480
85,620
90,990
117,660
125,030
137,610
116,190
123,470
135,890
122,210
134,510
144,900
162,630
175,190
186,170
160,600
173,010
183,850
158,970
171,240
235,310
250,060
275,220
232,380
246,940
271,790
244,420
269,010
289,790

27,090
27,090
27,090
29,980
29,980
29,980
32,840
32,840
32,840
40,190
40,190
40,190
44,370
44,370
44,370
48,570
48,570
48,570
54,300
54,300
54,300
60,100
60,100
60,100
65,720
65,720
79,600
79,600
79,600
88,320
88,320
88,320
97,320
97,320
97,320

16,530
16,530
16,530
18,610
18,610
18,610
20,640
20,640
20,640
24,200
24,200
24,200
27,140
27,140
27,140
30,090
30,090
30,090
32,930
32,930
32,930
37,020
37,020
37,020
41,050
41,050
45,960
45,960
45,960
52,400
52,400
52,400
59,200
59,200
59,200

10,300
10,300
10,300
12,370
12,370
12,370
14,440
14,440
14,440
15,170
15,170
15,170
18,290
18,290
18,290
21,410
21,410
21,410
12,330**
12,330**
12,330**
12,370
12,370
12,370
14,440
14,440
18,000**
18,000**
18,000**
18,290
18,290
18,290
21,410
21,410
21,410

11-8

17-9

23-9

35-10

Connections

13-0
13-0
13-0
13-9
13-9
13-9
14-6
14-6
14-6
13-0
13-0
13-0
13-9
13-9
13-9
14-6
14-6
14-6
13-0
13-0
13-0
13-9
13-9
13-9
14-6
14-6
13-0
13-0
13-0
13-9
13-9
13-9
14-6
14-6
14-6

2-10
2-10
2-10
3-7
3-7
3-7
4-4
4-4
4-4
2-10
2-10
2-10
3-7
3-7
3-7
4-4
4-4
4-4
2-10
2-10
2-10
3-7
3-7
3-7
4-4
4-4
2-10
2-10
2-10
3-7
3-7
3-7
4-4
4-4
4-4

Coil[5,6]

Overflow

Spray
Pump
(USGPM)

8-4

610

8-4

900

8-4

1,240

8-4

1,800

Internal
Coil Volume
(gal)

NOTES:
1. Nominal tons of cooling represents the capability to cool 3 USGPM
of water from a 95F entering water temperature to an 85F leaving
water temperature at a 78F entering wet-bulb temperature.

5. Standard coil connections are beveled for welding.

2. Fan horsepower is at 0 external static pressure.

7. If discharge hoods with positive closure damper are furnished, see


page C91 for added weight and height. Fan motor horsepower may
increase; consult selection software for verification.

3. Operating weight is for the unit with the water level in the cold water
basin at the overflow and a full coil.
4. Unless marked with a double asterisk (**), the coil section is the
heaviest section.

6. The number and location of coil connections will vary with design flow
and coil arrangement.

8. The riser pipe diameter is 6.

Do not use for construction. Refer to factory certified dimensions. This catalog includes data current at
the time of publication, which should be reconfirmed at the time of purchase.
C89

Q U E S T I O N S ? C A L L 4 1 0 . 7 9 9 . 6 2 0 0 O R V I S I T W W W. B A LT I M O R E A I R C O I L . C O M

365
365
365
453
453
453
541
541
541
545
545
545
677
677
677
809
809
809
730
730
730
906
906
906
1,082
1,082
1,090
1,090
1,090
1,354
1,354
1,354
1,618
1,618
1,618

Discharge Hoods with Positive Closure Dampers

Both tapered and straight discharge hoods with factory mounted positive closure dampers and damper actuators are
available for all Series V Closed Circuit Cooling Towers. Hoods are designed to minimize heat loss from convective air
flow through an idle unit. The addition of factory installed insulation to the hood and casing further reduces the heat loss
by minimizing losses due to conduction. Heat loss data is presented on page C91 for units without hood, with hood, and
with insulated casing and hood. Damper actuators and linkage are factory mounted on the hood.
All wiring and actuator controls must be furnished by others. 115 volt single phase power supply is required. Damper
actuators should be interlocked with the temperature control system so that the dampers are open when the pumps are
running and closed when the pumps are off.
The additional external static pressure of the tapered discharge hood with dampers may require the use of a larger fan
motor; consult selection software for verification. Consult your local BAC Representative for a unit drawing with a hood
and positive closure dampers.
L

W
1 1/2

1 1/2

1 1/2

1 1/2

1 1/2

1 1/2

1 1/2

Access
Door

1 1/2

Access
Door

Access
Door

10

10

Tapered

Model
Number

Number of Hoods
Required

VFL-012
VFL-024
VFL-036
VFL-048
VFL-072
VFL-096
VF1-009
VF1-018
VF1-027
VF1-036
VF1-048
VF1-072
VF1-096
VF1-144N
VF1-144
VF1-192
VF1-216
VF1-288N
VF1-288
VF1-432

1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
2
1
2
2
2

2-12
3-11
6-11
9-10
6-11
8-3
2-11
3-11
6-11
9-10
8-3
8-3
8-3
14-2
8-3
8-3
14-2
14-2
8-3
14-2

2-4
2-4
2-4
2-4
4-1
4-1
1-5
1-5
1-5
1-5
2-4
3-1
4-1
3-8
6-4
4-1
5-11
3-8
6-4
5-11

Access
Door

Straight

Total Shipping
Weight (lbs)

Total Shipping
Weight (lbs)

2-10[2]
2-10[2]
2-10[2]
2-10[2]
4-3[2]
4-3[2]
3-2[1]
3-2[1]
3-2[1]
3-2[1]
4-9[1]
4-9[1]
4-5[2]
4-5[2]
4-5[2]
4-5[2]
4-5[2]
4-5[2]
4-5[2]
4-5[2]

220[4]
330[4]
470[4]
590[4]
910 [4]
1,100[4]
280[3]
470[3]
640[3]
760[3]
1,240[3]
1,540[3]
1,200[4]
1,750[4]
1,550[4]
2,400[4]
2,150[4]
3,500[4]
3,100[4]
4,300[4]

3
5-3
8-3
11-2
8-3
11-2
3
5-1
8-3
11-2
11-2
10-6
11-2
16-8
11-2
11-2
16-8
16-8
11-2
16-8

3-1
3-1
3-1
3-1
6-4
6-4
3-1
3-1
3-1
3-1
4-1
5-10
6-4
6-4
10-4
6-7
10-4
6-4
10-4
10-4

3-1[2]
3-1[2]
3-1[2]
3-1[2]
3-1[2]
3-1[2]
3-1[2]
3-1[2]
3-1[2]
3-1[2]
3-10[2]
3-10[2]
3-10[2]
3-10[2]
3-10[2]
3-10[2]
3-10[2]
3-10[2]
3-10[2]
3-10[2]

260[4]
410[4]
540[4]
760[4]
960[4]
1,200[4]
300[3]
490[3]
680[3]
840[3]
1,220[3]
1,620[3]
1,320[4]
1,820[4]
1,750[4]
2,640[4]
2,400[4]
3,640[4]
3,500[4]
4,800[4]

NOTES (APPLICABLE TO SPECIFIC MODELS ONLY):


1. On these models, the discharge hood surrounds the drift eliminators and
is recessed into the drift eliminator frame; therefore, the overall height of
the unit with hood equals H (of unit) plus H (of hood) minus 4.

2. On these units, the hood sits directly on top of the casing.


3. Includes drift eliminators and skid.
4. Includes skid only. Drift eliminators are included in unit weight.

PRODUCT & APPLICATION HANDBOOK 2012

C90

Series V Engineering Data


V F L H E A T L O S S D A T A ( B T U H ) [1]
Model Number
(VFL Models Only)
VFL-012-02

V F 1 H E AT L O S S D ATA ( B T U H ) [1]

Standard Unit
Heat Loss
(BTU/HR)

Unit w/ Hood
& Positive Closure
Dampers

Unit w/ Hood,
Positive Closure
Dampers &
Insulation[2]

19,200

16,500

11,000

Unit w/ Hood
& Positive
Closure Dampers

Unit w/ Hood,
Positive Closure
Dampers &
Insulation[2]

VF1-009-12

24,300

17,100

10,300

VF1-009-22

29,400

18,800

12,000

VF1-009-32

32,900

20,500

12,000

VF1-009-42

34,800

22,200

13,700

VF1-018-02

34,700

25,600

15,400

Model Number
( VF1 Models Only)

VFL-012-12

25,000

17,800

11,900

VFL-012-22

29,900

19,200

12,800

VFL-012-32

33,800

20,500

13,700

VFL-024-12

48,200

28,500

19,000

VF1-018-12

46,200

27,300

15,400

VFL-024-22

57,700

30,400

20,300

VF1-018-22

56,000

29,100

17,100

VFL-024-32

65,400

32,300

21,500

VF1-018-32

64,300

30,800

17,100

VF1-018-42

70,950

32,550

18,800

VF1-027-22

86,100

46,100

27,300

VF1-027-32

97,700

49,500

29,100

VF1-027-42

106,300

52,900

29,100

VFL-036-22

87,000

47,100

30,700

VFL-036-33

98,400

49,800

32,500

VFL-048-22

126,400

66,000

42,600

VFL-048-31

138,800

69,300

44,800

VF1-036-21

112,600

63,200

39,300

VFL-048-41

151,200

72,600

47,000

VF1-036-31

128,900

66,600

39,300

VFL-072-22

210,900

84,400

56,200

VF1-036-41

145,200

70,000

43,600

VF1-036-51

161,500

73,400

43,600

VF1-048-21

154,900

80,200

52,900

VF1-048-31

177,200

83,700

52,900

VF1-048-41

197,000

85,600

54,600

VF1-072-21

212,400

83,700

51,200

VF1-072-31

241,100

87,100

51,200

VF1-072-41

269,800

90,500

56,800

VF1-096-31

286,700

97,600

60,000

VF1-096-41

312,100

102,600

60,900

VF1-096-51

329,800

107,900

61,700

VF1-144N-21

381,400

128,300

81,300

VF1-144N-31

429,900

134,700

82,800

VF1-144N-41

464,800

141,400

84,400

VF1-144-21

385,000

139,900

88,600

VF1-144-31

435,500

146,900

90,200

VF1-144-41

474,600

154,200

91,900

VF1-192-31

576,300

228,400

153,600

VF1-192-41

627,300

240,100

156,700

VF1-192-51

662,800

252,500

160,100

VF1-216-21

579,900

194,000

122,900

VF1-216-31

653,500

203,700

125,100

VF1-216-41

707,300

213,800

127,300

VF1-288N-21

762,800

256,600

162,600

VF1-288N-31

859,800

269,400

165,600

VF1288N-41

929,600

282,800

168,800

VF1-288-21

750,800

260,300

171,900

VF1-288-31

849,300

273,300

175,000

VF1-288-41

925,600

286,800

178,300

VF1-432-21

1,142,500

390,000

259,400

VF1-432-31

1,287,400

409,500

264,000

VF1-432-41

1,393,500

429,800

268,500

VFL-072-31

234,100

87,900

58,600

VFL-072-41

252,900

91,400

60,900

VFL-096-41

311,700

103,600

69,000

NOTES:
1. Heat loss is based on 50F (10C) coil water and -10F (-23C)
ambient with a 45 MPH wind. Fan(s) and pump(s) are off.
2. One inch thick PVC nitrite rubber blend thermal insulation with
protective paint.

C91

Standard Unit
Heat Loss
(BTU/hr)

Q U E S T I O N S ? C A L L 4 1 0 . 7 9 9 . 6 2 0 0 O R V I S I T W W W. B A LT I M O R E A I R C O I L . C O M