Sanitation Test Kits Overview

Neogen offers sanitation monitoring test kits to detect adenosine triphosphate (ATP), a substance found in all animal, vegetable, bacteria, yeast and mold cells; food protein residues; and microbial contamination. AccuPoint 2 Sanitation Monitoring System measures the ATP collected from food contact surfaces or liquids as an indication of the cleanliness of the surface or purity of the liquid. AccuPoint 2 works by measuring the light created when ATP contacts a reagent in the systems unique sampling devices (see page 11 for a description of how our AccuPoint 2 Sanitation Monitoring System works). The higher the levels of food residue and microorganisms in a surface or water sample, the more ATP present, and the more light produced. AccuClean is a simple test for the detection of protein and some sugars on food production surfaces. This fully self-contained test requires no instrument for reading and can be operated with a minimum of training. Its ideal for food service applications and food processors who want an objective, inexpensive and quick method to gauge their sanitation levels but cannot justify a full ATP sanitation monitoring program. Hylabs products are agar dip slide paddles specially designed to enable reliable, economic and timesaving monitoring of microbiological hygiene. Use directly on the work surface, dip into fluids or transfer from a conventional swab.

ATP Detection
AccuPoint 2 Sanitation Monitoring System...................................................................................................................................... 62

Protein Detection
AccuClean Sanitation Surface Samplers............................................................................................................................................ 64

Total Plate Count


Hylabs Total Count............................................................................................................................................................................. 64

Coliforms and Generic E. coli


Hylabs Coliforms and Generic E. coli................................................................................................................................................ 64

Yeast and Mold


Hylabs Yeast and Mold....................................................................................................................................................................... 64

Sales & Service: 800/234-5333 (USA/Canada) or 517/372-9200 Fax: 517/372-2006 www.neogen.com

61

Sanitation Test Kits AccuPoint 2


Sanitation Monitoring System
Consistently Accurate

Food Safety Online Ordering


www.neogen.com

The samplers vertical sampling technique increases downward pressure on the surface. This helps penetrate surface crevasses, and break up existing biofilms to uncover previously protected organisms. The sponge will reabsorb the liquid, with any present organic matter or bacteria, for consistently accurate results.

Sampler

Buffer Sample Pad

Intended Use
Neogens AccuPoint 2 ATP Sanitation Monitoring System is a lightweight, handheld system that validates the effectiveness of a sanitation program by detecting food residues and microorganisms present on surfaces and in liquids. The system utilizes easy-to-use AccuPoint samplers, which automatically mix prepared reagents to quickly generate results.

Cartridge

The Test
The AccuPoint system utilizes adenosine triphosphate (ATP) bioluminescence to determine the cleanliness of test samples. ATP is a chemical compound found in all living cells, including bacteria, food debris, yeast and mold. Bioluminescence is a chemical reaction that produces light. ATP bioluminescence occurs when ATP from a sample comes into contact with luciferase, an enzyme found in fireflies, and luciferin, a substrate. The amount of light emitted in this reaction is proportional to the amount of ATP detected in a sample. After a sample is taken the sampler is pressed into its cartridge, breaking its seal and initiating the mixing of reagents. The cartridge contains a buffering solution, which flushes the ATP onto a pad containing the reagents. The reaction takes place within the cartridge and a detector measures the amount of light produced. The reading is displayed on the LCD display in relative light units (RLU). According to preset limits, an icon is displayed indicating a pass, marginal or fail result. These limits are defined by the operator or by using the system presets. Sampler Extender (optional) Three samplers engineered for precise sampling in each unique applicationflat surfaces, water samples and tight spaces such as small orifices and channels

Luciferase and Luciferin

62

Sales & Service: 800/234-5333 (USA/Canada) or 517/372-9200 Fax: 517/372-2006 www.neogen.com

Sanitation Test Kits AccuPoint 2


Sanitation Monitoring System
The Procedure
1. Sample surface or water

Food Safety Online Ordering


www.neogen.com

Results
After the countdown, the data reading is displayed. Easy to interpret icons indicate a pass, marginal or fail result. Results can be recorded, and uploaded to a PC for easy data analysis.

Time Site No. Site Group Test Site

Date User

Result Record Count Battery Indicator Pass Marginal Fail

Use the Access sampler for tight spaces AccuPoint comes with Data Manager software that allows customers to: upload results to a PC, set pass/caution/fail levels, create and print trend analysis graphs, export data to spreadsheets, and keep a record of sanitation effectiveness to verify SSOPs. Results can be presented in a clear chart format showing the actual measurement in color coded green (pass), yellow (caution) and red (fail) for extra clarity. Accumulated results can be graphed using bar or pie charts, over a variety of criteria, for clear pictures of sanitation testing results and trends.

2. Return the sampler to its cartridge and insert all of the way.

3. Shake cartridge twice

Ordering Information
Prod.# 9602 9605 9606 9607 9610 9611 9612 9613 12359 9617 9618 9619 Product description AccuPoint 2 Sanitation Monitoring System - Includes monitor, NiMH battery pack, power supply data cable, DataManager software and Users Guide AccuPoint ATP Surface Samplers (100) AccuPoint Water Samplers (100) AccuPoint Access Samplers (100) NiMH Battery Replacement Pack Sampler Extender AccuPoint Cleaning Kit (5 swabs) AccuPoint Stand-up Holster AccuPoint Communications Cable AccuPoint DataManager Software Hawking Technologies USB Serial Converter ATP Standards Kit

4. Press the eject button and insert the sampler into the instrument. Close unit door and read results.

Sales & Service: 800/234-5333 (USA/Canada) or 517/372-9200 Fax: 517/372-2006 www.neogen.com

63

Sanitation Test Kits AccuClean


Protein Detection Surface Samplers

Food Safety Online Ordering


www.neogen.com

Hylabs
Dip Slide Paddles

Intended Use
AccuClean is intended to be used as a simple method to determine the cleanliness of food contact surfaces and equipment. The user simply rubs the samplers tip across a surface, places the sampler back in its cartridge and activates the test by depressing the plunger through the cartridge. After 10 minutes, the sampling tip is compared to a color chart to gauge the level of protein detected.

Intended Use
Hylabs products are agar slides specially designed to enable reliable, economic and timesaving monitoring of microbiological hygiene. Use directly on the work surface, dip into fluids or transfer from a conventional swab.

Product Specifications
Sensitivity: Testing time: Storage: Tests per kit: Contact - 1 CFU/cm2 Dipping - 103 CFU/cm2 Total Count - 48 hours Coliforms and Generic E. coli - 18 hours Yeast and Mold - 48 hours Room temperature 20

Results
A color change will occur within the small disc located at the bottom of the cartridges cup. To best interpret the tests result, insert the cup into the hole in the color chart provided with the tests.
PASS FAIL

MARGINAL

FAIL

Results

Ordering Information
Prod.# 9670 Product description AccuClean Sanitation Surface Samplers - one pack contains 100 ready-to-use disposable single use devices.

Ordering Information
Prod.# 9111 9114 9113 Product description Hylabs Total Count Hylabs Yeast & Mold Hylabs Coliforms and Generic E. coli

64

Sales & Service: 800/234-5333 (USA/Canada) or 517/372-9200 Fax: 517/372-2006 www.neogen.com