The 5300 Series Automatic Recirculation Control ARC valve performs four separate functions within the pumping circuit, all within one compact body.
Features
Saves Power Costs - Eliminates the need for continuous recirculation to cool the pump. Saves System Engineering Time - Includes reverse flow prevention, low flow detection, recirculation flow control, and recirculation flow pressure reduction. - Eliminates multiple vendor complexities associated with systems combining various pneumatic, thermal and mechanical components. Saves Installation and Maintenance Costs - Needs no electrical wiring, plant or instrument air. - Eliminates other components of a conventional system. - Eliminates multiple pressure reducing orifices and capillary tubes. - Eliminates duplication created by two control valves in a series one for pressure reduction and one for tight shut-off. Reduces Downtime - Minimizes the problems of high velocity wiredrawing and cavitation erosion common to high pressure drop service.

Sizes
3" to 12" main discharge feed. 1" to 3" recirculation discharge. Flanged or Butt Welding end connections.

Pressures
Classes 600, 900, 1500, 2500.

Temperature Limitations
500F

Flow Control

Yarway is either a trademark or registered trademark of Tyco International Services AG or its affiliates in the United States and/or other countries. All other brand names, product names, or trademarks belong to their respective holders. Copyright 2009 Tyco Flow Control. All rights reserved. YAWMC-0489-US-0908

Yarway 5300 Series ARC Valve


For Centrifugal Pump Protection

Piston positions bypass


control valve.

Check Valve
prevents reverse flow and detects low flow.

Bypass Control Valve


permits passage of limited cooling water flow through pump during low load.

Discharge Nozzle
provides back pressure for fluid condition control.

Bypass Flow Ports


provide passage for minimum cooling flow to bypass control valve.

Lever triggers pilot valve. Flutes reduce pressure by redirecting flow.

Cascade Piston
dissipates energy of high pressure discharge.

Pilot Valve
activates cascade element.

Copyright 2009 Tyco Flow Control. All rights reserved.

YAWMC-0489 2

Yarway 5300 Series ARC Valve


For Centrifugal Pump Protection

Automatic Recirculation Control Valve


During critical low load periods, centrifugal feed pumps need a reliable recirculation system to prevent pump instability and overheating. Because many such systems are constructed of a number of components, the systems can become both complex and costly, requiring substantial outlays for design, installation and maintenance. Yarways 5300 ARC valve, on the other hand, is a complete system within itself. It actually performs four separate functions within the pumping circuit all within one compact body. Essentially, the 5300 ARC valve is a check valve installed in the main line. But it also acts as the sensing and powering element which pilots the operation of a recirculation control valve. The sensing system responds to changes in flow rather than pressure. The control valve incorporates a pressure reducing device that divides recirculation flow and guides the resulting streams through successive 90 turns to dissipate the destructive energies of high pressure while controlling fluid velocity. But perhaps even more importantly, the 5300 ARC valve recirculates only that flow needed to cool a feed pump at critical times of low load rather than permitting a continuous recirculation flow. The valve therefore saves the electrical power that continuous recirculation would consume, which can cost several thousand dollars per year.

Control Loop System


Storage vessel Gate valve (optional) Multiple pressurereducing orifice Four-way air solenoid valve

Recirculation control valve FIC To process Gate valve (optional) Flow meter

Gate or control valve

Check valve Pump Sensing orifice

Yarway System
Remote back pressure regulator (optional) Storage vessel Check valve To process

Bypass element

One Valve Four Functions


Flow sensing that actuates the pilot or the bypass control valve which permits passage of a limited flow of cooling liquid during low load periods. This flow is delivered to the cascade element which dissipates the energy for quiet, safe delivery to the deaerator, condenser or other low pressure sink. Check valve prevents reverse flow through the feed pump.

Gate or control valve

Automatic recirculation valve

Pump

Copyright 2009 Tyco Flow Control. All rights reserved.

YAWMC-0489 3

Yarway 5300 Series ARC Valve


For Centrifugal Pump Protection

How it Works
The ARC valve is installed in the pump discharge line in the position of the main check valve it replaces. It is adaptable to horizontal or vertical piping and to either horizontal or vertical upward flow. Flanged or welded ends are optional to suit specifications. Decreasing flow through the valve causes the spring loaded disc to move toward its seat. At a flow rate determined by the minimum flow requirement through the pump, the disc triggers the pilot valve through the lever. This vents the pressure on the head of the piston. Pressure acting on the opposite side of the piston opens the bypass valve, permitting flow through the multi-stage cascade element. The flow rate through the bypass valve is equal to the minimum flow requirement of the pump. The directional changes of the successive helical flutes, as well as the multiple orifices, provide for the absorption of pressure energy. The bypass valve will remain in an open position as long as the pilot valve is open. This corresponds with the position the disc assumes at flow rates between an established low flow and no flow through the main check valve. As the flow rate exceeds the minimum flow rate, the rising disc allows the pilot valve to close; pressure entering the chamber over the piston through the annular clearance around the pilot.

Main Flow
Normal Main Flow
Check Valve - Open Pilot Valve - Closed Cascade Valve - Closed

Main Flow

* Normal Flow Range - flow rate between maximum pump delivery and required minimum flow rate of pump.

Normal Flow Range* Check Valve Fulcrum Main Flow from Pump Pilot Valve Cascade Piston Bypass Flow

Low Main Flow


Check Valve - at Switch Point Pilot Valve - Partially Open Cascade Valve - Opening

Main Flow

Check Valve Fulcrum Main Flow from Pump Pilot Valve Cascade Piston

Bypass Flow

Low Main Flow


Check Valve - Closed Pilot Valve - Open Cascade Valve - Open

Main Flow

Check Valve Fulcrum Main Flow from Pump Pilot Valve Cascade Piston

Bypass Flow

Copyright 2009 Tyco Flow Control. All rights reserved.

YAWMC-0489 4

Yarway 5300 Series ARC Valve


For Centrifugal Pump Protection

How it Works

Valve Installation (common line to receiver)

Receiver vessel

Piping Installation (separate line to receiver)

Receiver vessel

Check valve

To process

To process Check valve

Flow from feed pump

3R Elbow radius equal to 3 times normal pipe size

Flow from feed pump

3R Elbow radius equal to 3 times normal pipe size

How to Specify
Centrifugal pump minimum flow protection shall be provided by a self-contained multi-function valve which requires no external source of power. The valve shall provide the functions of: 1. Spring loaded check valve to prevent pump damage from reverse flow. 2. Flow sensor that will activate bypass valve at the specified minimum flow. 3. Bypass flow control valve, sized to provide the minimum required pump flow. 4. Pressure reducing device to effectively reduce high pump discharge pressures to low receiver tank/sump pressures. Actuation of the bypass valve shall be by direct contact of the switching mechanism to the check valve disc. No levers or linkages shall be utilized. Bypass trim travel shall have a 1:1 proportional ratio with the flow sensing disc travel to provide truly optimum modulated flow control. One piece operating element shall be preferred for maximum reliability. The bypass trim shall also be capable of providing extended bypass control service. Service limitations or manual bypass lines for extended bypass service shall not be acceptable. The ARC valve shall be designed and constructed in accordance with ANSI B16.34. Pressure reduction in the bypass shall be the vendors responsibility to control flashing, cavitation and choked flow conditions both within the trim and at the valve discharge. Sealing surfaces in trim shall be located in an area where it will not be prone to erosion and/or cavitation damage. Valves shall be flow tested by the manufacturer, and certified performance curves shall be provided with the valve shipment.

Copyright 2009 Tyco Flow Control. All rights reserved.

YAWMC-0489 5

Yarway 5300 Series ARC Valve


For Centrifugal Pump Protection

Series 5300 ARC


Parts and Material
Item Part
7
8 6 6

Material
ASTM A-216 Grade WCB AISI 302 Stainless Steel ASTM A276-S21800 (Nitronic 60 Bar) Steel AISI 304 Stainless Steel TFE/Propylene ASTM A-216 Grade WCB ASTM A276-S21800 (Nitronic 60 Bar) ASTM A193 Grade B7 ASTM A-216 Grade WCB ASTM A351 Type CF8M ASME SA564-S63000 COND A ASTM A313-S30200 ASTM A747 Grade CB7Cu-1 (17-4 PH Cast) Condition H900 (J92180) ASME SA564-S63000 COND A ASTM A582-S41600 ASTM A582-S41600 COND T ASTM A276-S43100 AISI 420F ASME SA479 S41000 ASTM A747 Grade CB7Cu-1 (17-4 PH Cast) Condition H900 (J92180) ASME SA564-S63000 COND A TFE/Propylene TFE/Propylene Stainless Steel 18-8 ASTM A193 Grade B7 Turcon T11 (Glyd Ring) TFE/Propylene ASTM A276-S43100 TFE/Propylene TFE/Propylene TFE/Propylene ASME SA479-S31600

12 Size RFFlange Flange Size RF Per ANSI Per ANSIB16.5 B16.5 2 3 4 51 62


C 1/16

Body 1-A Liner Body Bushing Retaining Ring Liner O-ring Bonnet Guide Ring Cap Screw Body Bypass Disc Disc Pin Spring Control Head (I/C) Control Head (Bar Stock) Lever Pivot Pin Pilot Valve Pilot Valve Nut Cascade Piston Cascade Seat Bushing Piston Guide Pin (3", 10", 12") O-ring O-ring Guide Pin Cap Screw Seal Ring O-ring Pilot Valve Seat O-ring O-ring O-ring Orifice

5 4 E Stage E Stage Cascade Cascade


D RF Flgd ANSI B16.5

7 8 92 10 12 13 14

13 13

10 15
12 12 1 1

2 3

9 9

B 1/32

14 15 16 171 18 191 201

A 1/32

Series 5300 ARC E Stage Cascade


22 22 25 25

21 221 231 241 25 261 271 341 351 361 391 40


40 40

1-A 1-A 17 17 18 18 16 16

14 14

22

23 23

19 19

20 20

26 26 27 27

34 34 35 35 36 36

39 39 24 24

Notes:
1. Recommended spare parts. 2. Type 316 SS construction available upon request.

Copyright 2009 Tyco Flow Control. All rights reserved.

YAWMC-0489 6

Yarway 5300 Series ARC Valve


For Centrifugal Pump Protection

Series 5300 ARC Flange Ends


A 1/ 32

C 1/ 32 D RF Flange Per ANSI B16.5

B 1/ 32

Flanged Ends (Data for 11/2", 2" and 21/2" valves available upon request)
*Valve Size in. [DN]
3 3 3 3 4 4 4 4 6 6 6 6 8 8 8 8 10 10 10 10 12 12 12 [75] [75] [75] [75] [100] [100] [100] [100] [150] [150] [150] [150] [200] [200] [200] [200] [250] [250] [250] [250] [300] [300] [300]

Class ANSI
600 900 1500 2500 600 900 1500 2500 600 900 1500 2500 600 900 1500 2500 600 900 1500 2500 600 900 1500

Figure No.
5302 5304 5306 5308 5302 5304 5306 5308 5302 5304 5306 5308 5302 5304 5306 5308 5302 5304 5306 5308 5302 5304 5306

A
10 1/2 10 1/2 10 1/2 13 15 1/2 15 1/2 15 1/2 18 1/4 17 5/8 17 5/8 17 5/8 22 1/ 2 21 21 21 See 28 1/ 2 28 1/ 2 28 1/ 2 32 1/2 32 7/ 8 32 7/ 8 32 7/ 8

Dimensions, in. [mm] B


6 [152.4] 6 [152.4] 6 13/16 [173.0] 7 9/16 [192.1] 6 3/4 [171.5] 6 3/4 [171.5] 8 3/16 [208.0] 9 1/16 [230.2] 9 1/4 [235.0] 9 9/16 [242.9] 11 [279.4] 12 [304.8] 11 7/ 8 [301.6] 11 7/ 8 [301.6] 11 7/ 8 [301.6] See Note 2 13 7/16 [341.3] 13 7/16 [341.3] 14 13/16 [376.2] 18 7/16 [468.3] 15 1/ 2 [393.7] 15 1/ 2 [393.7] 17 1/ 8 [435.0]

C
17 1/16 [433.4] 17 1/16 [433.4] 19 7/8 [504.8] 21 7/8 [555.6] 19 5/16 [490.5] 19 9/16 [496.9] 24 5/16 [617.5] 26 1/8 [663.6] 25 13/16 [655.6] 26 1/8 [663.6] 30 15/16 [785.8] 32 15/16 [836.6] 33 13/16 [858.8] 33 13/16 [858.8] 3313/16 [858.8] See Note 2 361/ 2 [927.1] 361/ 2 [927.1] 41 3/16 [1046.2] 52 1/16 [1322.4] 40 1/ 4 [1022.4] 40 1/ 4 [1022.4] 48 [1219.2]

(D) Bypass Flange Size in. [DN]


1 [25] 1 [25] 1 [25] 1 [25] 11/2 [40] 11/2 [40] 11/2 [40] 11/2 [40] 2 [50] 2 [50] 2 [50] 2 [50] 21/2 [65] 21/2 [65] 21/2 [65] See Note 2 3 [80] 3 [80] 3 [80] 3 [80] 3 [80] 3 [80] 3 [80]

Weight lb. (kg)


170 (77) 200 (91) See Note 2 See Note 2 300 (136) 340 (154) 525 (238) 560 (254) 680 (308) 740 (336) 1400 (635) 1480 (671) 1180 (535) 1330 (603) 1730 (785) See Note 2 1900 (862) 2000 (907) 3020 (1370) 5000 (2268) 2350 (1066) 2600 (1179) See Note 2

Rated Main Flow gpm


400 400 400 400 750 750 750 750 1600 1600 1600 1600 2800 2800 2800 2800 4200 4200 4200 4200 5500 5500 5500

[266.7] [266.7] [266.7] [330.2] [393.7] [393.7] [393.7] [463.6] [447.7] [447.7] [447.7] [571.5] [533.4] [533.4] [533.4] Note 2 [723.9] [723.9] [723.9] [825.5] [835.0] [835.0] [835.0]

Notes: 1. 14" and 16" sizes available.


2. Contact your sales representative for more information.

Copyright 2009 Tyco Flow Control. All rights reserved.

YAWMC-0489 7

Yarway 5300 Series ARC Valve


For Centrifugal Pump Protection

Series 5300 ARC Butt Welding Ends


A 1/ 32

C 1/ 32 D RF Flange Per ANSI B16.5

B 1/ 32

Butt Welding Ends (Data for 11/2", 2" and 21/2" valves available upon request)
*Valve Size in. [DN]
3 3 3 3 4 4 4 4 6 6 6 6 8 8 8 8 10 10 10 10 12 12 12 12 [75] [75] [75] [75] [100] [100] [100] [100] [150] [150] [150] [150] [200] [200] [200] [200] [250] [250] [250] [250] [300] [300] [300] [300]

Class ANSI
600 900 1500 2500 600 900 1500 2500 600 900 1500 2500 600 900 1500 2500 600 900 1500 2500 600 900 1500 2500

Figure No.
5301 5303 5305 5307 5301 5303 5305 5307 5301 5303 5305 5307 5301 5303 5305 5307 5301 5303 5305 5307 5301 5303 5305 5307

Dimensions, in. [mm] B


6 6 61/ 8 61/ 8 61/ 2 61/ 2 8 3/16 8 3/16 9 3/ 4 9 3/ 4 11 10 3/ 4 12 7/ 8 12 7/ 8 12 7/ 8 13 5/16 14 5/16 14 5/16 1415/16 15 3/16 15 1/2 15 1/2 17 1/ 8 17 1/4 [152.4] [152.4] [155.6] [155.6] [165.1] [165.1] [208.0] [208.0] [247.6] [247.6] [279.4] [273.0] [327.0] [327.0] [327.0] [338.1] [363.5] [363.5] [363.5] [385.8] [393.7] [393.7] [435.0] [438.2]

C
17 1/16 17 1/16 19 19 19 1/16 19 1/16 23 7/ 8 23 7/ 8 26 9/16 26 9/16 3015/16 30 11/16 34 7/ 8 34 7/ 8 34 7/ 8 35 1/ 4 37 3/ 8 37 3/ 8 40 3/16 4013/16 40 1/4 40 1/4 48 48 [433.4] [433.4] [482.6] [482.6] [484.2] [484.2] [606.4] [606.4] [674.7] [674.7] [785.8] [779.5] [885.8] [885.8] [885.8] [895.3] [949.3] [949.3] [1020.8] [1036.6] [1022.4] [1022.4] [1219.2] [1219.2]

(D) Bypass Flange Size in. [DN]


1 1 1 1 11/2 11/2 11/2 11/2 2 2 2 2 21/2 21/2 21/2 21/2 3 3 3 3 3 3 3 3 [25] [25] [25] [25] [40] [40] [40] [40] [50] [50] [50] [50] [65] [65] [65] [65] [80] [80] [80] [80] [80] [80] [80] [80]

Weight lb. [kg]


130 (59) 136 (62) See Note 2 See Note 2 275 (125) 285 (129) 450 (204) 470 (213) 600 (272) 640 (290) 1125 (510) 1200 (544) 950 (431) 1025 (465) 1290 (585) 2400 (1089) 1400 (635) 1600 (726) 2150 (975) 4150 (1882) 1570 (712) 1740 (789) See Note 2 See Note 2

Rated Main Flow gpm


400 400 400 400 750 750 750 750 1600 1600 1600 1600 2800 2800 2800 2800 4200 4200 4200 4200 5500 5500 5500 5500

101/ 2 [266.7] 101/ 2 [266.7] 101/ 2 [266.7] 13 [330.2] 15 1/ 2 [393.7] 15 1/ 2 [393.7] 15 1/ 2 [393.7] 18 1/ 4 [463.6] 17 5/ 8 [447.7] 17 5/ 8 [447.7] 17 5/ 8 [447.7] 221/2 [571.5] 21 [533.4] 21 [533.4] 21 [533.4] 24 3/4 [628.6] 28 1/ 2 [723.9] 28 1/ 2 [723.9] 28 1/ 2 [723.9] 32 1/ 2 [825.5] 32 7/ 8 [835.0] 32 7/ 8 [835.0] 32 7/ 8 [835.0] 42 [1066.8]

Notes: 1. 14" and 16" sizes available.


2. Contact your sales representative for more information.

Copyright 2009 Tyco Flow Control. All rights reserved.

YAWMC-0489 8

Yarway 5300 Series ARC Valve


For Centrifugal Pump Protection

Hydraulic Performance Test Lab

Performance Profiled in Yarways Hydraulic Performance Test Lab


In our hydraulic performance test laboratory, state-of-the-art data acquisition and computer graphics techniques are called upon for evaluation of the significant performance characteristics of Yarway recirculation control valves. The labs equipment makes it possible to test a valve over its complete flow range for factors including: Total flow through the pump Disc position Pressure drop across the main check Bypass Cv Bypass P Valve response to sudden changes in flow Bypass piston pressure These detailed analyses are the users complete assurance that the valve meets performance requirements in all respects and can be supplied with the valve. A certified test curve is shipped with each valve (see page 10 for example). Insist on it, as you would for your pump!

Copyright 2009 Tyco Flow Control. All rights reserved.

YAWMC-0489 9

Yarway 5300 Series ARC Valve


For Centrifugal Pump Protection

Certified Test Curve


25.0

Main DP (PSID)

20.0 15.0 10.0 5.0 0.0 0 3.00 2.50 500 1000 1500 2000 2500

Disc Lift (IN)

2.00 1.50 1.00 0.50 0.00 0 16.0 14.0 12.0 500 1000 1500 2000 2500

Bypass Cv

10.0 8.0 6.0 4.0 2.0 0.0 0 500 1000 1500 2000 2500

Main (GPM)
2500.0

2000.0

Total Flow (GPM)

1500.0

1000.0

500.0

0.0 0 500 1000 1500 2000 2500

Main Flow (GPM)

Copyright 2009 Tyco Flow Control. All rights reserved.

YAWMC-0489 10

Yarway 5300 Series ARC Valve


For Centrifugal Pump Protection

How to Order
Our sales representatives will help you select the correct valve for your application. Please complete this form before contacting the sales office to help ensure all necessary information is provided.

Automatic Recirculating Control (ARC) Valve Data Sheet


Customer: Company: Project: Location: Phone: Qty Required: Tag(s) ID: Delivery Required: E-Mail: Additional Info:

Pump Flow
Normal -Process- flow: Maximum -Process- flow: Minimum -Process- flow (optional): Minimum pump protection flow:

Please Complete Flow Requirements GPM M3/H BPD

(if Minimum Flow is to be considered in sizing) (Minimum required Recirculation Flow) Please Complete Pressure Requirements psi bar KgF/cm2 Kpa

Pump Discharge Pressure


Pump pressure at Shut-off (zero flow): Pump pressure at Normal -Process- flow: Pump pressure at Minimum -Process- flow (optional): Pump pressure at Minimum pump protection flow: ARC Valve Bypass line pressure:

(if Minimum Flow is to be considered in sizing) (at Minimum required Recirculation Flow) (Line pressure at ARC Valve bypass port) Please Enter Both Temperatures

Temperature
Normal temperature at ARC Valve: Maximum temperature at ARC Valve:

Fluid
Liquid: Boiler Feed Water (In this case disregard S.G. and V.P.) Other (Please specify) _________________ Specific Gravity: Vapor Pressure: Viscosity: Orientation of ARC Valve: Desired End Connections: Vertical Horizontal

Raised Face Flange Ring Type Joint (RTJ) Flat Face Flange Butt Weld Ends Other - Specify in Comments 150 300 600 900 1500 2500

Desired Pressure Class: Desired Body Material:

A216 Gr. WCB A351 Gr. CF8M A351 Gr. CK3MCuN (6Mo) A995 Gr. CD3MWCuN (Super Duplex) Ethylene Propylene (EPR or EPDM) TFE Propylene (Aflas or Fluoraz) Fluorocarbon Rubber (Viton) Other - Specify in Comments Constant Speed - Motor Driven Variable Speed (VFD) - Motor Driven Variable Speed - Turbine Driven Other - Specify in Comments

Desired Seal Material (except 2" to 8" 9200 and 9300):

Pump Drive Type:

Comments:

NACE Materials Required? Flow Test with Performance Certificate Required? Customer Inspection Required Prior to Shipment?

Certificate of Compliance for Hydro Test Required? Magnetic Particle Test Required? Radiograph Inspection Required (specify scope)?

Certified Material Test Report (Pressure Containing Components only)?

Flow tests are generally conducted on all model 5300 and 7100 ARC valves and one model 9100 or 9200 ARC valve per sales order line item at no additional cost. Model 9300 ARC valves and other flow test requirements are upon request and at additional cost. If flange drilling is other than ANSI, please specify in Comments. Please include Pump Curve if available.

Copyright 2009 Tyco Flow Control. All rights reserved.

YAWMC-0489 11

Yarway 5300 Series ARC Valve


For Centrifugal Pump Protection

Tyco Flow Control (TFC) provides the information herein in good faith but makes no representation as to its comprehensiveness or accuracy. This data sheet is intended only as a guide to TFC products and services. Individuals using this data sheet must exercise their independent judgment in evaluating product selection and determining product appropriateness for their particular purpose and system requirements. TFC MAKES NO REPRESENTATIONS OR WARRANTIES, EITHER EXPRESS OR IMPLIED, INCLUDING WITHOUT LIMITATION ANY WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE WITH RESPECT TO THE INFORMATION SET FORTH HEREIN OR THE PRODUCT(S) TO WHICH THE INFORMATION REFERS. ACCORDINGLY, TFC WILL NOT BE RESPONSIBLE FOR DAMAGES (OF ANY KIND OR NATURE, INCLUDING INCIDENTAL, DIRECT, INDIRECT, OR CONSEQUENTIAL DAMAGES) RESULTING FROM THE USE OF OR RELIANCE UPON THIS INFORMATION. Patents and Patents Pending in the U.S.and foreign countries. Tyco reserves the right to change product designs and specifications without notice. All registered trademarks are the property of their respective owners. Printed in the USA.

Copyright 2009 Tyco Flow Control. All rights reserved.

YAWMC-0489 12

www.tycoflowcontrol.com

Vous aimerez peut-être aussi