Vous êtes sur la page 1sur 3

Gateway SAUTER Bticino

Use the Sauter & Bticino technology :


Solutions for every need, from today the integration of Sauter and BTicino is possible. STItalia with its gateway and Firmware for control by bticinos touch screen, make possible the dialogue between the two systems through the integrated management of all devices. Only making plants in home automation technology it is possible to integrate more system, or make them talk to each other, while also achieving significant energy savings.

Product Description

Based on BACnet protocol

Additional features provided to you by this integration are thus to expand capacity, flexibility and offer the Bticino My Home facilities. Think at the freedom to automatically set the optimum temperature, the convenience of turn on and off the heating system at any time, the possibility of bring the temperature in standby automatically when you're not at home. All this at a distance, via internet or from your mobile phone, for the benefit of your comfort and energy balance of your home, for a significant savings. This is what home automation can do for you. This is the real total comfort.

Using a touch screen Bticino model H4690, after installing the "SAUTER BACnet" firmware and St Italia BACnet gateway, you can give a good and simple solution to the management and of thermoregulation managed with BACnet protocol and SAUTER systems, in environments such as schools , hotels, communities or villas. Using an intuitive graphical interface, you can keep under control the temperature status of all zones controlled SAUTER, change the set point and display up to two technical alarm for zone, all taking the advantage and the proven qualities of solidity and reliability of touch screen Bticino My Home, making simple the management of the SAUTER thermoregulation plant in My Home system.

Via G.Toniolo, 28 30030 Vigonovo (VE)

www.stitalia.com info@stitalia.com

Gateway SAUTER Bticino


What is necessary to use with My Home :
In order to exploit the potential is required the presence in system of the following physical components. One or more Touch screen H4690 St Italia Gateway & Firmware for touch A dedicated Network to interconnect the system.

Product Description

Based on BACnet protocol

All components it must be connected at the bacnet layer on a separate data network. In the touch H4690 in which it was installed and configured the firmware "SAUTER BACnet" will appear a screen of thermoregulation modified to interact with the evolved thermoregulation system. The functions that can display the firmware in touch, will be: Display external temperature probe. Control setpoint for each zone. Display internal temperature probe in each area. Visualization of the relative humidity of each area Management of technical alarms and system alerts. The information that can be displayed by the firmware are strictly dependent on the hardware and program of SAUTER system.
Example of Firmware BACnet SAUTER for Touch 10 H4690

Gateway Technical Data :


Power Asorption Ex. temperature Ex. Humidity IP Grade Mounting Dimension Colour Power Conn. Ethernet Conn. : : : : : : : : : : DC 9 - 24 V Max 300mA 0 C - +55 C 80% no cond. IP 20 Inide cabinet DIN Rail 6 module 107 x 110 x 65 mm Grey RAL 7035 Removable clamp RJ45 LAN 10Mbit

Diffusion :
Marketed in the world from June 2012

Via G.Toniolo, 28 30030 Vigonovo (VE)

www.stitalia.com info@stitalia.com

Gateway SAUTER Bticino


H4690

Product Description

Based on BACnet protocol

H4690

H4690

Network switch

H4690

St Italia SAUTER Gateway

Installation example of SAUTER Gateway.

Via G.Toniolo, 28 30030 Vigonovo (VE)

www.stitalia.com info@stitalia.com

Vous aimerez peut-être aussi