SESAM User Course GeniE Workshop: A quick introduction to punching shear, member and plate code checking

To learn new users how to model a structure and apply loads and boundary conditions to do Joint modelling (cans, stubs, cones) and tubular punching shear check Member code check and re-design Plate code check based on the PULS standard

The structure and loads are highly fictitious as the main purpose is to give a quick introduction to modelling and code checking in one simple model that you can model within a few hours. Program defaults are used for all code check runs If this is your first exposure to GeniE you should do the tutorial B1- A small introduction to GeniE

DNV Software Sesam GeniE_CC_Intro_Workshop Rev. date 12 March 2011

DNV SOFTWARE

Sesam

GeniE

Program versions You need GeniE version D5.3-07 or later. This tutorial can be executed from GeniE.lite except for the plate code checking. If you have the full version of GeniE your license file must include code checking for beams and plates as well as structural analysis. You can recreate this workshop (except the report creation) by making a new workspace and importing the file B10_in.js. If you want to recreate the structure and the loads only you can use the file B10_clean.js

Content 1. Start the program 2. Define section properties 3. Define material 4. Define thickness 5. Define guide plane 6. Define upper elevation 7. Define the vertical columns 8. Define the lower deck 9. Model the tubular joints 10. Add boundary conditions 11. Define the loads 12. Define mesh settings and run analysis 13. Look at results 14. Code checking 15. Make a report Page 3 Page 3 Page 8 Page 9 Page 10 Page 12 Page 22 Page 23 Page 28 Page 33 Page 34 Page 39 Page 40 Page 42 Page 48

DNV Software Sesam GeniE_CC_Intro_Workshop Rev. date 12 March 2011

DNV SOFTWARE

Sesam

GeniE

1. Start the program, create a new workspace (File|New Workspace) and name it Test. Let the units be in N and m.

2. Start by defining section properties. For this tutorial you will need the following section types: L-profiles: Jap_L150x90x9x9, Jap_L200x90x9x14 & Jap_L250x90x10x15 T-bar: Tbar425x120x12x25 & Tbar630x150x12x30 I-bar: HEA140A, HEA200A, HEA240A Pipe OD406.4x10, OD508x10, OD610x10, OD813x10 All the sections can be imported from the section library. To import the L-profiles:

Click Create/Edit Section

DNV Software Sesam GeniE_CC_Intro_Workshop Rev. date 12 March 2011

DNV SOFTWARE

Sesam

GeniE

Click Section Library

Click Browse

Select anglebar.xml and click open

DNV Software Sesam GeniE_CC_Intro_Workshop Rev. date 12 March 2011

DNV SOFTWARE

Sesam

GeniE

Browse until you find the section types Jap_L150x90x9x9 Jap_L200x90x9x14 Jap_L250x90x10x15 and click OK You can select all three in one operation by using ALT+CLICK Click OK

Click OK

There are now three sections in your section library You can look at and edit the details by selecting one of them, RMB and choose Edit (Do not modify if you want the same results as in this tutorial)

DNV Software Sesam GeniE_CC_Intro_Workshop Rev. date 12 March 2011

DNV SOFTWARE

Sesam

GeniE

Repeat the same process for the other profiles. For the T-bar you find the profiles in Tbar425x120x12x25 & Tbar630x150x12x30

For the I-profiles you find the details in HEA140A, HEA200A, HEA240A

For the tubes you find the sections in OD406.4x10, OD508x10 OD610x10, OD813x10

DNV Software Sesam GeniE_CC_Intro_Workshop Rev. date 12 March 2011

DNV SOFTWARE

Sesam

GeniE

You should now have the following sections:

You can also view, modify and create new sections from the browser

Select a section type, RMB & Edit to modify a section

Right click the folder Section to insert a new section

Click Save
DNV Software Sesam GeniE_CC_Intro_Workshop Rev. date 12 March 2011

DNV SOFTWARE

Sesam

GeniE

3. Define a material S235 Either define the material from Edit>Properties>Material or From browser as shown:

Right click the folder Materials

Add the details as shown

Click OK

DNV Software Sesam GeniE_CC_Intro_Workshop Rev. date 12 March 2011

DNV SOFTWARE

Sesam

GeniE

4. Define a thickness Th15 (15mm) for the upper deck Either define the material from Edit>Properties>Thickness or From browser as shown

Right click the folder Thicknesses

Add the details as shown notice that the units are given in mm

Click OK

Click Save
DNV Software Sesam GeniE_CC_Intro_Workshop Rev. date 12 March 2011

DNV SOFTWARE

Sesam

GeniE

5. Define a guide plane for the definition of the upper deck Insert > Guiding Geometry > Guide Plane Dialog

Give it a name and fill in the details as follows

1. Set the elevation to 10m 2. Modify P2, P3 and P4 as shown P1, 0, 0, 10 P2: 15, 0 , 10 P3: 15, 15, 10 P4: 0, 15, 10 3. Modify u and v as shown u spacings: 15 v spacings: 3 4. Click OK

Click OK
DNV Software Sesam GeniE_CC_Intro_Workshop Rev. date 12 March 2011

DNV SOFTWARE

10

Sesam

GeniE

You should now see the guide plane in the graphics window Remember that the display mode should be set to Default Display If you still dont see the guide plane, click on fit to screen (or F9)

If you want to switch from colour background to white background do so by ALT+B or from View > Options > General In the following all graphics are shown with white background

Click ALT+B

DNV Software Sesam GeniE_CC_Intro_Workshop Rev. date 12 March 2011

DNV SOFTWARE

11

Sesam

GeniE

6. Define the upper elevation built up from L and T profiles and a plate thickness Start by defining defaults From the browser Sections select the profile Jap_L250x90x10x15, RMB and set as default

You can see that this is the default section from the Browser

Pulldown menu

Set the material S235 (from browser materials) and thickness Th15 (from browser Thicknesses) to default

DNV Software Sesam GeniE_CC_Intro_Workshop Rev. date 12 March 2011

DNV SOFTWARE

12

Sesam

GeniE

Insert the L-profiles frtom the menu Insert > Beam > Straight Beam

Move the cursor over the guide plane until you see that it prompts you with the number 1 and Click. This means that you have now selected the start point of the beam and GeniE is now waiting for the end point.

Click

DNV Software Sesam GeniE_CC_Intro_Workshop Rev. date 12 March 2011

DNV SOFTWARE

13

Sesam

GeniE

Move the cursor over the guide plane until you see that it prompts you with the number 2 and Click. You have now inserted the first beam

Click Click

The beam can also be found in the browser for any type of manipulation

DNV Software Sesam GeniE_CC_Intro_Workshop Rev. date 12 March 2011

DNV SOFTWARE

14

Sesam

GeniE

Select the beam (click on it), then right click the selection and choose Copy Use a vector of (1, 0, 0) and do a multiple copy of 13. The preview is shown

Click Apply

There are now 14 beams

DNV Software Sesam GeniE_CC_Intro_Workshop Rev. date 12 March 2011

DNV SOFTWARE

15

Sesam

GeniE

Modify the selected beams (Bm5 and Bm10) to section profile Tbar425 Select the beams, Right Click and choose Properties

Select Tbar425 and click OK

Click OK

Bm5 and Bm10 have now new section properties assigned Properties can also be changed from the browser by choosing the new section, right click and Apply Section to Selection

DNV Software Sesam GeniE_CC_Intro_Workshop Rev. date 12 March 2011

DNV SOFTWARE

16

Sesam

GeniE

Insert beams at the outer boundaries of the upper deck Select beam Bm10, RMB and select copy

Use translation vector (5, 0, 0)

Click Apply
Repeat the copy by using a translation vector (-10, 0, 0)

Click Apply
DNV Software Sesam GeniE_CC_Intro_Workshop Rev. date 12 March 2011

DNV SOFTWARE

17

Sesam

GeniE

Insert beams at the outer boundaries of the upper deck Change the default section to Tbar630

Then insert beams as shown E.g. from Insert -> Beam > Straight Beam and click start and stop

Insert the plate from Insert > Plate > Flat Plate Dialog and click on the four corner points as shown

4 1 3

2
DNV Software Sesam GeniE_CC_Intro_Workshop Rev. date 12 March 2011

DNV SOFTWARE

18

Sesam

GeniE

The structure now looks as

Select all the beams and the plate (e.g. rubber-band select) and choose named set. Give the set name Upper_deck

The sets can be referred to from the browser Utility Sets

DNV Software Sesam GeniE_CC_Intro_Workshop Rev. date 12 March 2011

DNV SOFTWARE

19

Sesam

GeniE

The final modelling task for the upper deck is to flush all beams below the deck Select the set Upper-deck from the browser Utility Sets In the graphics window right click (RMB) and select Edit Beams

Select 1. Offset Vector, 2. Align Section and 3. Flush top

2 3

Click OK
All beams now receive eccentricities based on their section properties

DNV Software Sesam GeniE_CC_Intro_Workshop Rev. date 12 March 2011

DNV SOFTWARE

20

Sesam

GeniE

The picture below is shown using the display settings Modelling Transparent

The following picture includes colour coding of the section properties Hint: Make the picture, right click on the sections (from the browser) and select colour coding To remove colour coding from the graphics click the paintbrush button

Click Save
DNV SOFTWARE

DNV Software Sesam GeniE_CC_Intro_Workshop Rev. date 12 March 2011

21

Sesam

GeniE

7. Insert the vertical columns Change default setting to OD610 Start inserting a vertical column by Insert > Beam > Straight Beam

4 1 3 2
1. Click in the field above (End 1) 2. Click in the graphical window to find the start position 3. Click in the field above (End 2) 4. Click in the graphical window to find the x and y coordinates of the end position 5. Subtract 10 m from the z-coordinate 6. Copy the highlighted tube to the three remaining corners

5 6

DNV Software Sesam GeniE_CC_Intro_Workshop Rev. date 12 March 2011

DNV SOFTWARE

22

Sesam

GeniE

8. Define the lower deck Change default setting to HE240A The lower deck elevation is at +2.5 m and a temporary snap plane will be used to define snap points along the columns at elevation +2.5 m 1. Start by clicking on the arrow next to the symbol for snap perpendicular

1
2. Select the Snap plane option

2
3. Make sure the Snap Plane symbol is activated (pushed in) and type in the z-elevation 2.5 m.

4. Start inserting beams graphically. Make sure that the insert beam button is activated (ticked off) and that the snap point is also activated.

DNV Software Sesam GeniE_CC_Intro_Workshop Rev. date 12 March 2011

DNV SOFTWARE

23

Sesam

GeniE

You can now insert the beams by clicking at the snap points as defined in the intersection between the columns and the temporarily snap plane The first beam is defined by clicking as shown below.

2
The second beam is also defined in the same manner

2 1
The two remaining beams between the columns are inserted in the same directions as the previous beams

DNV Software Sesam GeniE_CC_Intro_Workshop Rev. date 12 March 2011

DNV SOFTWARE

24

Sesam

GeniE

Create the inner parts of the lower deck by 1. Copy the selected beam 2 times with a vector of (5,0,0)

2. Copy the selected beam (Bm28) 14 times with a vector (0, 1, 0)

3. Select all the beams in the lower deck, RMB and choose Named Set. Make a new named set Lower_deck and include the selection

DNV Software Sesam GeniE_CC_Intro_Workshop Rev. date 12 March 2011

DNV SOFTWARE

25

Sesam

GeniE

4. Change the section properties of the below selected beams to HE140A

5. Finally, modify the sections of the selected beams to HE200A

6. Select all the beams in the lower deck, RMB and select Edit Beam. Perform a flush operation from the offset vector tab

DNV Software Sesam GeniE_CC_Intro_Workshop Rev. date 12 March 2011

DNV SOFTWARE

26

Sesam

GeniE

A detailed view of the lower deck may be (seen from below):

Click Save

DNV Software Sesam GeniE_CC_Intro_Workshop Rev. date 12 March 2011

DNV SOFTWARE

27

Sesam

GeniE

9. Model the tubular joint part 1. Start by changing the default section to OD406. Insert the beam as shown below by using a snap plane at elevation 6.25m. See previous pages on how do it

1 2 + snap plane at el. 6.25m

2. Insert the bracings in the sequence (1-4) as shown below

1 3 2

DNV Software Sesam GeniE_CC_Intro_Workshop Rev. date 12 March 2011

DNV SOFTWARE

28

Sesam

GeniE

3. Define joints for use in joint design. A joint is inserted from the joint button or from Insert > Joint > Joint Dialog

Insert two joints as shown below. To be able to see the joints the symbol for joints needs to be activated

4. Perform the joint design by selecting the joints, RMB and choose Add Can/Stub This example is based on using the default values as given under Edit > Rules > Joint design Each joint will now have both cans and stubs

DNV Software Sesam GeniE_CC_Intro_Workshop Rev. date 12 March 2011

DNV SOFTWARE

29

Sesam

GeniE

From browser Properties Reinforcement click on AutoCan, RMB and choose Select Objects. Modify the selected cans so that they receive section property OD813.

1 2

The structure should now look as

Repeat the process above for the cans and modify the sections of these to OD508 for stubs

DNV Software Sesam GeniE_CC_Intro_Workshop Rev. date 12 March 2011

DNV SOFTWARE

30

Sesam

GeniE

The structure should now look as

Add conical transitions by selecting the joints and the connected cans and stubs. Make sure that the joint symbol for selection is activated and that the select beam filter is set to Filter Segment.

You can do a rubber-band select to include the joint and the cans & stubs. Right click and select Add Cone to selected beams/segments

DNV Software Sesam GeniE_CC_Intro_Workshop Rev. date 12 March 2011

DNV SOFTWARE

31

Sesam

GeniE

The structure should now look as (remember to set the beam filter back to default)

Finally, perform a gap calculation by selecting the joints (remember that you need to activate the Joint selection button), RMB and select Add Gap. The structure looks like:

DNV Software Sesam GeniE_CC_Intro_Workshop Rev. date 12 March 2011

DNV SOFTWARE

32

Sesam

GeniE

10. Add Boundary conditions Insert boundary conditions from the support button Click at the ends of each column to insert a support Modify the two highlighted support points (select them, RMB and Properties) so that they are free to move in Dx, Dy, Rx, Ry and Rz

Click Save
DNV SOFTWARE

DNV Software Sesam GeniE_CC_Intro_Workshop Rev. date 12 March 2011

33

Sesam

GeniE

11. Define the loads There will be a total of 6 loadcases for this example there are 5 basic load cases and 1 load combination 1. Selfweight 2. X_acceleration 3. Upper_pressure 4. Equipments_U_deck 5. Equipments_L_Deck 6. Combo (a combination of 1-5) Start by defining the load case names from Insert > Load Case

The load combination is defined from Insert > Load Combination

The load cases can be modified from the browser Analysis Load Cases

DNV Software Sesam GeniE_CC_Intro_Workshop Rev. date 12 March 2011

DNV SOFTWARE

34

Sesam

GeniE

Selfweight Select the load case Selfweight, RMB and click properties. Make sure you tick off for Include structure selfweight in structural analysis. The acceleration is the same as gravity

X-acceleration Modify this load case by ticking off for Include structure selfweight in structural analysis and modifying the acceleration vector to Vector3d(1 m/s^2,0 m/s^2,0 m/s^2)

DNV Software Sesam GeniE_CC_Intro_Workshop Rev. date 12 March 2011

DNV SOFTWARE

35

Sesam

GeniE

Upper_pressure From the Insert > Explicit Load > Surface Load define a pressure of -5 KPa to the plate of the upper deck. Before you do so, select the load case Upper_pressure, RMB and Set current. Click on each plate corner to fill in the co-ordinate values and specify the intensity to -5KPa.

DNV Software Sesam GeniE_CC_Intro_Workshop Rev. date 12 March 2011

DNV SOFTWARE

36

Sesam

GeniE

Equipments_U_deck Select the load case Equipments_U_deck and set it to current. Define the equipments Box1 and Pump1 from Insert > Equipment > Prism Equipment as follows:

Place the equipments in the load case as follows: From the folder Equipment, select Box1, RMB and choose Place in Loadcase. Drag the equipment to a temporary position, select it and choose Properties. Type in the exact coordinate values of the position of the equipments bottom centre (11, 2, 10).

DNV Software Sesam GeniE_CC_Intro_Workshop Rev. date 12 March 2011

DNV SOFTWARE

37

Sesam

GeniE

Place the equipment Pump1 in the same way as described on the previous page, but the coordinate values of the bottom centre shall be (3, 10, 10). The load-case shall now look like

Equipments_L_deck Select the load case Equipments_L_deck and set it to current. Define the equipment ToolBox1 and place it in the load case at the following position (8, 7.5, 2.5). Use the techniques as described on the previous pages.

DNV Software Sesam GeniE_CC_Intro_Workshop Rev. date 12 March 2011

DNV SOFTWARE

38

Sesam

GeniE

12. Define mesh settings and run analysis. Specify one mesh setting Md_plate = 1m and apply to the plate. From browser Properties Mesh you define the new mesh setting Apply this mesh setting to the plate in the upper deck

Before analysis you should check the model from Tools > Structure > Verify. The analysis is started from Tools > Analysis > Activity Monitor (or ALT+D). This will set up Analysis 1 and by clicking on OK you can start the analysis

DNV Software Sesam GeniE_CC_Intro_Workshop Rev. date 12 March 2011

DNV SOFTWARE

39

Sesam

GeniE

13. Look at results. This tutorial includes 2 examples on post-processing Global deformations Change the view settings to Results with Mesh and set the load case Combo to current. Most likely you see the mesh, but not any results. From the Tools > Analysis > Presentation (ALT+P) you define which result attribute to view.

You should check out the other options to present results from the Tools > Analysis > Presentation

DNV Software Sesam GeniE_CC_Intro_Workshop Rev. date 12 March 2011

DNV SOFTWARE

40

Sesam

GeniE

Beam stresses Change the view settings to Modelling Structure. Select the beam(s) you want to compute the forces on Start the beam computation from Tools > Analysis > Beam Force/Stress Diagram In the example below the axial stresses of Bm18 are computed (a Tbar 630 profile) for the load combination Combo for hotspot 8.

Click on the tab Graphs to see the diagram. If you run analysis with 2nd order elements the diagram becomes more smooth.

DNV Software Sesam GeniE_CC_Intro_Workshop Rev. date 12 March 2011

DNV SOFTWARE

41

Sesam

GeniE

14. Code checking There are three examples in this tutorial. They are meant as a quick introduction for more details you should consult the other relevant tutorials or the User manuals. Member code checking 1. From browser Capacity insert a new Capacity Manager

2. From the folder Capacity CC_Member you create the members as shown

3. From the folder Capacity CC_Member you add a run as shown (default settings are used for the code check run) You should check out the options of modifying the code check parameters

DNV Software Sesam GeniE_CC_Intro_Workshop Rev. date 12 March 2011

DNV SOFTWARE

42

Sesam

GeniE

4. From the folder Capacity CC_Member you compute the code check forces for a run as shown

5. From the folder Capacity CC_Member you perform the code check.

6. From the folder Capacity CC_Member CC_Member(run1) you can look at results

Alternatively from the view setting Capacity Models. Select all members, RMB, Color Code, Results, UfTot

DNV Software Sesam GeniE_CC_Intro_Workshop Rev. date 12 March 2011

DNV SOFTWARE

43

Sesam

GeniE

Tubular punching shear check 1. From browser Capacity insert a new Capacity Manager

2. From the folder Capacity CC_Joint you create the joints as shown

3. From the folder Capacity CC_Joint you add a run as shown (default settings are used for the punching shear check) You should check out the options of modifying the code check parameters

DNV Software Sesam GeniE_CC_Intro_Workshop Rev. date 12 March 2011

DNV SOFTWARE

44

Sesam

GeniE

4. From the folder Capacity CC_Joint you compute the code check forces (default settings are used for the code check Capacity Manager) 5. From the folder Capacity CC_Joint you perform the code check. 6. From the folder Capacity CC_Member CC_Member(run1) you can look at results

Alternatively from the view setting Capacity Models. Select all members, RMB, Color Code, Results, UfTot

DNV Software Sesam GeniE_CC_Intro_Workshop Rev. date 12 March 2011

DNV SOFTWARE

45

Sesam

GeniE

PULS Plate code checking Un-stiffened panels 1. From browser Capacity insert a new Capacity Manager

2. From the folder Capacity CC_Puls you create the panels as shown

3. From the folder Capacity CC_Puls you add a run as shown (default settings are used for the plate code check) You should check out the options of modifying the code check parameters, e.g. if you want to run for stiffened panel

DNV Software Sesam GeniE_CC_Intro_Workshop Rev. date 12 March 2011

DNV SOFTWARE

46

Sesam

GeniE

4. From the folder Capacity CC_Puls you compute the code check forces (default settings are used for the code check Capacity Manager) 5. From the folder Capacity CC_Puls you perform the code check. 6. From the folder Capacity CC_Member CC_Member(run1) you can look at results

Alternatively from the view setting Capacity Models. Select all members, RMB, Color Code, Results, UfTot

Click Save

DNV Software Sesam GeniE_CC_Intro_Workshop Rev. date 12 March 2011

DNV SOFTWARE

47

Sesam

GeniE

15. Make a report Generate a report that includes some content for the structure, the loads and all the code checks. This is just an example so you should test out the other chapters. The chosen format is a MS Word report, but you can also test out a plain text file, html or MS Excel. From the File > Save Report 1. Give it a file name (e.g. This_is_a_file) 2. Give it a report name, this will be in the report heading (e.g. B10) 3. Select report format (e.g. WordXML)

3 1
4. Click on Structure 5. Click on Add Selected

4
DNV Software Sesam GeniE_CC_Intro_Workshop Rev. date 12 March 2011

DNV SOFTWARE

48

Sesam

GeniE

15. Make a report 6. Click on Report 7. Click on Loads 8. Click on Add Selected

6 8 7
9. Click on report 10. Click on Frame Code Check 11. Click on Add Selected

9 11 10
12. Select Capacity Manager to CC_Member, add lower limit for UfTot to 0.5 and modify the Chapters as shown below

12

DNV Software Sesam GeniE_CC_Intro_Workshop Rev. date 12 March 2011

DNV SOFTWARE

49

Sesam

GeniE

15. Make a report 13. Click on Report 14. Click on Frame Code Check 15. Click on Add Selected

13 15 14
16. Select Capacity Manager to CC_Joint, add lower limit for UfTot to 0.2 and modify the Chapters as shown below Click on report

16

17. Click on Report, Plate Code Check, Add Selected, set Capacity Manager to CC_Puls, and use lower limit 0.3

17

DNV Software Sesam GeniE_CC_Intro_Workshop Rev. date 12 March 2011

DNV SOFTWARE

50

Sesam

GeniE

15. Make a report 18. Click on Save 19. Click on View to see the report in MSWord

17

18

Click Exit to quit and save


File > Exit

DNV Software Sesam GeniE_CC_Intro_Workshop Rev. date 12 March 2011