Vous êtes sur la page 1sur 2

BOS 12M-NS-1PD-S4-C Ordering code: BOS000E

Diffuse sensor Series 12M Working range: bis 400 mm

NPN (1x), NO (pin 4) Infrared DC, direct current

1) Optical axis, 2) Sn, 3) Output function

Voltage drop Ud max. (at Ie)

2,5 V

Characteristic data
Degree of protection as per IEC 60529 Short-circuit protected Protected against polarity reversal Protected against reverse connection Indicator Setting Adjuster Switching freq. f max. IP67 yes yes yes Output function - LED YE Switching distance (Sn) Potentiometer 270 (1x) 200 Hz

Mechanical data
Connector type Eff. switching distance Sr Shock rating Vibration rating Temp. drift max. (% of Sr) Ambient temperature Degree of contamination Sensing surface material Housing material Surface protection Repeat accur. R max. (% of Sr) Mounting type Contact surface protection Design Capture range Sd Beam characteristic Range Sn Minimum operating distance M12x1-S04 400 mm Half-sinus, 30gn, 11ms, 3x6 10-55 Hz, 1 mm ampl., 3x30 min 10 -5...55 C 3 PMMA Brass Nickel-plated 5% Nut M12x1 Gold plated Cylinder, straight optics 0...400 mm Divergent Sn = 400 mm, adjustable 0 mm

Optical data
Principle of optical operation Switching function, optical Light type Ambient light max. Light scanner, energetic NO: light-on Infrared 2,000 Lux

Electrical data
Operating voltage Rated operating voltage Ue DC Effective operating current Ie Rated insulation voltage Ui Ready delay tv max. Utilisation category Hysteresis H max. (in % of Sr) Load capacitance max. (at Ue) Output resistance Ra Off-state current Ir max. Ripple max. (% of Ue) Switching output Switching function Turn-off delay toff max. Turn-on delay ton max. No-load current max. Io at Ue 10...30 V DC 24 V 200 mA 75 V DC 100 ms DC 13 30 % 1 F 33 kOhm 50 A 15 % NPN (1x) NO (pin 4) 2,5 ms 2,5 ms 20 mA

Basic data
Connection Connector, M12x1-S04 Basic standard IEC 60947-5-2 The sensor is functional again after the overload has been eliminated. Reference object (target): Gray card, 200 x 200, 90 % remission, axial approach. With connector, e.g. BKS-S 20- total length = switch length +18 mm. Only for NFPA 79 applications (machines with a supply voltage of maximum 600 volts). Device shall be connected only by using any R/C (CYJV2) cord, having suitable ratings. Order accessories separately.

Internet Balluff Germany Balluff USA Balluff China

: www.balluff.com : +49 (0) 7158 173-0, 173-370 : 1-800-543-8390 : +86 (0) 21-50 644131

1 (2) Print date: 20.08.2012 Selection date: 20.08.2012

BOS 12M-NS-1PD-S4-C Ordering code: BOS000E


Diffuse sensor Series 12M Working range: bis 400 mm

NPN (1x), NO (pin 4) Infrared DC, direct current

Internet Balluff Germany Balluff USA Balluff China

: www.balluff.com : +49 (0) 7158 173-0, 173-370 : 1-800-543-8390 : +86 (0) 21-50 644131

2 (2) Print date: 20.08.2012 Selection date: 20.08.2012

Vous aimerez peut-être aussi