www.balmoraltanks.com
Water storage
Septic tanks
A septic tank is designed to provide what is known as primary treatment to crude wastewater produced in a normal domestic environment. It retains solids and allows them to settle out, where they can be partially broken down by biological action so that only the remaining liquor is left to ow down the outlet drain. This liquor (normally called e uent) is then su ciently treated to soak into the ground in an underground soakaway system.
Balmoral CAP
Balmorals best selling sewage treatment plant is universally popular across the UK and the Republic of Ireland and provides full treatment to crude sewage produced in normal domestic situations. Balmoral CAP e uent can be discharged directly into a watercourse without having to pass through a soakaway.
Speci cations
Population served Max hydraulic load (l/day) Organic load (g BOD5/day) NH3 (g/per day) Total capacity (litres) Diameter (mm) Height to ground level (mm) Empty plant weight (kg) Energy usage (kWh/day) Desludging interval (months)
BST27
1-4 800 n/a n/a 2700 1840 2400 197 0 12
BST38
5-10 2000 n/a n/a 3800 2045 2640 240 0 12
BST45
11-14 2800 n/a n/a 4500 2165 2770 275 0 12
BST60
15-22 4400 n/a n/a 6000 2365 3005 335 0 12
Speci cations
Population served Max hydraulic load (l/day) Organic load (g BOD5/day) NH3 (g/per day) Total capacity (litres) Diameter (mm) Height to ground level (mm) Empty plant weight (kg) Energy usage (kWh/day) Desludging interval (months)
CAP6
1-6 1200 360 48 3800 2045 2640 250 1.4 12
Capacity
(litres) 1250 1365 1800 2600 3500 3635 5455 7270 10000
Length
(mm) 1800 1300 1400 1580 2800 1800 2000 2085 2330
Width
(mm) 1320 1300 1400 1580 1700 1800 2000 2085 2330
Height
(mm) 915 1320 1500 1665 1326 1778 2100 2426 2920
Speci cations
Population served Max hydraulic load (l/day) Organic load (g BOD5/day) NH3 (g/per day) Total capacity (litres) Length (mm) Width (mm) Height to ground level (mm) Empty plant weight (kg) Energy usage (kWh/day) Desludging interval (months)
HC6
1-6 1200 360 48 4440 3400 1250 2450 450 1.8 12
HC12
7-12 2400 720 96 5950 4500 1400 2450 550 2.5 9
HC20
13-20 4000 1200 160 7960 5680 1400 2450 700 2.7 6
HC30
21-30 6000 1800 240 11410 9600min 1400 2450 1030 3.6 6
HC40
31-40 8000 2400 320 14920 1400 2450 1190 5.2 6
HC50
41-50 10000 3000 400 18400 1400 2450 1590 5.7 6
10780min 14780min
Underground tanks
UG1370 UG2410 UG3090
Capacity
(litres) 1370 2410 3090
Length
(mm) 1900 2350 3200
Width
(mm) 1150 1350 1350
Height
(mm) 1969 2171 2171
1500L tank
2900L tank
1500+2900L tanks
2900+2900L tanks
Balmoral HydroStore
Capacity (litres) Length (mm) Width (mm) Height (mm) Empty tank weight (kg) Inlet invert (mm) Pipework tting (mm) Filter checking interval
RWH1500
1500 2400 1200 1250 110 500 (Can be extended) 110 12 months
RWH2900
2900 2400 2400 1250 200 500 (Can be extended) 110 12 months
Balmoral RWH-ST
Capacity (litres) Diameter (mm) Height (mm) Footprint (mm) Empty tank weight (kg) Inlet invert (mm) Pipework tting (mm) Filter checking interval
RWH-ST-45
4546 2165 2770 1275 260 830 (Can be reduced) 110 12 months
RWH-ST-60
6000 2365 3005 1275 310 830 (Can be reduced) 110 12 months
Balmoral Hydrostack
The Balmoral Hydrostack has been specifically designed for the supply of water in emergency situations. These tanks are ideally suited for use in situations such as water shortages due to summer droughts, burst water pipes or Water Authority maintenance periods where supply is temporarily cut-off.
HEAD OFFICE AND FACTORIES Balmoral Park, Loirston, Aberdeen AB12 3GY, Scotland Tel +44 (0)1224 859000 Fax +44 (0)1224 859123 Email tanks@balmoral.co.uk www.balmoraltanks.com
WWT-4PP-0612-REV02