For further information regarding prices, availability and technical information please consult International Protective Coatings. We may at our discretion provide free of charge technical service support to customers consisting of the provision of a technical service representative who may periodically or on a reasonable request visit the site and liaise with the customer concerning product requirements, application training and general advice concerning our products. We accept no liability whatsoever in connection with the provision of or a failure to provide such free of charge technical support. We reserve the right to reassess this offer should the costs to us change significantly during the quotation period. Subject to our Standard Terms and Conditions which are available on request. http://www.international-pc.com/ Please also refer to our current Product & Material Safety Datasheets prior to using any products.
PAINTING SPECIFICATION
18/07/2006 Page 2
Summary
Area Description COATING SYSTEM NO.1A For External Application : INITIAL PAINTING - Carbon Steel Design Temperature < 110 C NON INSULATED in The Atmospheric Zone COATING SYSTEM NO.1B For External Application : MAINTENANCE PAINTING FOR BLAST CLEANED SURFACE - Carbon Steel Design Temperature < 110 C NON INSULATED In the Atmospheric Zone COATING SYSTEM NO.1C For External Application : MAINTENANCE PAINTING FOR POWER TOOL CLEANED SURFACE - Carbon Steel Design Temperature < 110 C NON INSULATED in the Atmospheric Zone COATING SYSTEM NO.2A For External Application : INITIAL PAINTING - Carbon Steel Design Temperature < 110 C INSULATED in the Atmospheric Zone COATING SYSTEM NO.2B For External Application : MAINTENANCE PAINTING FOR BLAST CLEANED SURFACE - Carbon Steel Design Temperature < 110 C INSULATED in the Atmospheric Zone COATING SYSTEM NO.2C For External Application : MAINTENANCE PAINTING FOR POWER TOOL CLEANED SURFACE - Carbon Steel Design Temperature < 110 C INSULATED in the Atmospheric Zone COATING SYSTEM NO.3A For External Application : INITIAL PAINTING AND MAINTENANCE PAINTING - Offshore Platform Decks (including primary and secondary structures) Environment Notes A low durability (upto 5 years) coating specification designed for environments classified by ISO 12944-2 as C5-I very high corrosivity (Industrial). This specification is intended for Maintenance and Repair. This specification is intended for Maintenance and Repair. A low durability (upto 5 years) coating specification designed for environments classified by ISO 12944-2 as C5-I very high corrosivity (Industrial). This specification is intended for Maintenance and Repair. This specification is intended for Maintenance and Repair.
A low durability (upto 5 years) coating specification designed for environments classified by ISO 12944-2 as C5-I very high corrosivity (Industrial). A low durability (upto 5 years) coating COATING SYSTEM NO.3B For External Application : INITIAL specification designed for environments PAINTING AND MAINTENANCE PAINTING (Alternative) - Offshore classified by ISO 12944-2 as C5-I very high Platform Decks (including primary and secondary structures) corrosivity (Industrial). A low durability (upto 5 years) coating COATING SYSTEM NO.4A For External Application : INITIAL specification designed for environments PAINTING AND MAINTENANCE PAINTING - Splash Zone and Spray classified by ISO 12944-2 as C5-I very high Zone corrosivity (Industrial). A low durability (upto 5 years) coating COATING SYSTEM NO.4B (ALTERNATIVE) For External specification designed for environments Application : INITIAL PAINTING AND MAINTENANCE PAINTING classified by ISO 12944-2 as C5-I very high Splash Zone and Spray Zone corrosivity (Industrial).
PAINTING SPECIFICATION
18/07/2006 Page 3
Summary
Area Description COATING SYSTEM NO.5A(1) For External Application : INITIAL PAINTING & MAINTENANCE PAINTING - Carbon Steel Design Facilities with Surface Temperature 110 250 C (INSULATED AND NON INSULATED) in the Atmospheric Zone COATING SYSTEM NO.5A(2) For External Application : INITIAL PAINTING & MAINTENANCE PAINTING - Carbon Steel Design Facilities with Surface Temperature 250 450 deg C (INSULATED AND NON INSULATED) in the Atmospheric Zone COATING SYSTEM NO.5B(1) For External Application : MAINTENANCE PAINTING FOR POWER TOOL CLEANED SURFACE - Carbon Steel Design Facilities with Surface Temperature 110 - 250 C (INSULATED AND NON INSULATED) in the Atmospheric Zone COATING SYSTEM NO.5B(2) For External Application : MAINTENANCE PAINTING FOR POWER TOOL CLEANED SURFACE - Carbon Steel Design Facilities with Surface Temperature 250 - 450 C (INSULATED AND NON INSULATED) in the Atmospheric Zone COATING SYSTEM NO.6A For External Application : INITIAL PAINTING - GALVANISED STEEL COATING SYSTEM NO.7A(1) For External Application : INITIAL PAINTING & MAINTENANCE PAINTING - Stainless Steel (NON INSULATED) facilities Operating < 110 C COATING SYSTEM NO.7A(2) For External Application : INITIAL PAINTING & MAINTENANCE PAINTING - Stainless Steel (INSULATED) facilities Operating < 110 C COATING SYSTEM NO.7A(3) For External Application : INITIAL PAINTING & MAINTENANCE PAINTING - Stainless Steel (INSULATED AND NON INSULATED) facilities Operating 110 - 540 C Environment Notes
A high performance coating specification designed for application over non-ferrous metals
COATING SYSTEM NO.8A For External Application : INITIAL PAINTING - Carbon Steel Storage Tank
COATING SYSTEM NO.8B For External Application : INITIAL AND MAINTENANCE PAINTING - Carbon Steel Storage Tank Underside of Bottom plate (ONLY if painting is required for corrosion protection to supplement cathodic protection)
The specification given is our nearest product match for the system based on information received. Without further details of environment and conditions of service we cannot be certain that the system specified will give the best performance and therefore do not accept any liability for the performance of the product or loss or damage (other than death or personal injury resulting from our negligence) arising out of use of the product. The specification given is our nearest product match for the system based on information received. Without further details of environment and conditions of service we cannot be certain that the system specified will give the best performance and therefore do not accept any liability for the performance of the product or loss or damage (other than death or personal injury resulting from our negligence) arising out of use of the product.
PAINTING SPECIFICATION
18/07/2006 Page 4
Summary
Area Description Environment Notes The specification given is our nearest product match for the system COATING SYSTEM NO.8C For External based on information received. Without further details of Application : Carbon Steel Storage Tank - Shell, environment and conditions of service we cannot be certain that the Roof Plate, Stairways, Stair Treads, Gangways And system specified will give the best performance and therefore do Others External parts include the piping (NON not accept any liability for the performance of the product or loss or GALVANISED) damage (other than death or personal injury resulting from our negligence) arising out of use of the product. COATING SYSTEM NO.9A For External Application : INITIAL AND MAINTENANCE A high performance coating specification for application on timbers. PAINTING - Timber Decks The specification given is our nearest product match for the system based on information received. Without further details of environment and conditions of service we cannot be certain that the COATING SYSTEM NO.10 For External system specified will give the best performance and therefore do Application : Timber Decks - Markings not accept any liability for the performance of the product or loss or damage (other than death or personal injury resulting from our negligence) arising out of use of the product. COATING SYSTEM NO.11 For External Application : Timber Decks - Living Quarters, A high performance coating specification for application on timbers. Pressurised Building, Control Room (Interior) COATING SYSTEM NO.13A For Internal A high performance coating specification for exposure in immersed Application : INITIAL PAINTING, MAINTENANCE environments. The specification provided is based on a maximum PAINTING FOR BLAST CLEANED SURFACE AND operating temperature of 50 C. Coatings for immersed conditions POWER TOOL CLEANED SURFACE - Fuel Gas require special consideration and you must contact International for (Sweet And Sour) for Service Temperature Up To detailed advice on preparation , application and cure prior to their 60 C use. A high performance coating specification for exposure in immersed COATING SYSTEM NO.14A(1) For Internal environments. The specification provided is based on a maximum Application : INITIAL PAINTING, MAINTENANCE operating temperature of 50 C. Coatings for immersed conditions PAINTING FOR BLAST CLEANED SURFACE AND require special consideration and you must contact International for POWER TOOL CLEANED SURFACE - Roof and detailed advice on preparation , application and cure prior to their Shell Plate Of Service Temperature Up To 60 C use. A high performance coating specification for exposure in immersed COATING SYSTEM NO.14A(2) For Internal environments. The specification provided is based on a maximum Application : INITIAL PAINTING, MAINTENANCE operating temperature of 50 C. Coatings for immersed conditions PAINTING FOR BLAST CLEANED SURFACE AND require special consideration and you must contact International for POWER TOOL CLEANED SURFACE - Bottom detailed advice on preparation , application and cure prior to their Plate and Vessels Up To 60 C use. COATING SYSTEM NO.14A(3) (Alternative) For A high performance coating specification for exposure in immersed Internal Application : INITIAL PAINTING, environments. The specification provided is based on a maximum MAINTENANCE PAINTING FOR BLAST CLEANED operating temperature of 50 C. Coatings for immersed conditions SURFACE AND POWER TOOL CLEANED require special consideration and you must contact International for SURFACE - Bottom Plate Of Service Temperature detailed advice on preparation , application and cure prior to their Up To 60 C use. COATING SYSTEM NO.15A For Internal A high performance coating specification for exposure in immersed Application : INITIAL PAINTING, MAINTENANCE environments. The specification provided is based on a maximum PAINTING FOR BLAST CLEANED SURFACE AND operating temperature of 50 C. Coatings for immersed conditions POWER TOOL CLEANED SURFACE - Naptha, require special consideration and you must contact International for Reformate, Jet A Fuel, Lube Oil, Fuel Oil, Gasoline detailed advice on preparation , application and cure prior to their (Leaded & Unleaded) For Service Temp. Up to 60 use. COATING SYSTEM NO.16A For Internal A high performance coating specification for exposure in immersed Application : INITIAL PAIINTING, MAINTENANCE environments. The specification provided is based on a maximum PAINTING FOR BLAST CLEANED SURFACE AND operating temperature of 50 C. Coatings for immersed conditions POWER TOOL CLEANED SURFACE - Diesel require special consideration and you must contact International for (Roof and Shell Plate) of Service Temperature Up detailed advice on preparation , application and cure prior to their to 60 C use.
PAINTING SPECIFICATION
18/07/2006 Page 5
Summary
Area Description COATING SYSTEM NO.16B For Internal Application : INITIAL PAIINTING, MAINTENANCE PAINTING FOR BLAST CLEANED SURFACE AND POWER TOOL CLEANED SURFACE - Diesel (Bottom Plate and Vessels) of Service Temperature Up to 60 C COATING SYSTEM NO.16C (ALTERNATIVE) For Internal Application : INITIAL PAIINTING, MAINTENANCE PAINTING FOR BLAST CLEANED SURFACE AND POWER TOOL CLEANED SURFACE Diesel (Bottom Plate and Vessels) of Service Temperature Up to 60 C COATING SYSTEM NO.17A For Internal Application : INITIAL PAINTING, MAINTENANCE PAINTING FOR BLAST CLEANED SURFACE AND POWER TOOL CLEANED SURFACE - Sea Water, Produced Water, Brackish, Demineralised Water, Brine of Service Temperature up to 60 C COATING SYSTEM NO.18A For Internal Application : INITIAL PAINTING, MAINTENANCE PAINTING FOR BLAST CLEANED SURFACE AND POWER TOOL CLEANED SURFACE - Steam (Condensate), Boiler Feed of Service Temperature up to 100 C COATING SYSTEM NO.19A For Internal Application : INITIAL PAINTING, MAINTENANCE PAINTING FOR BLAST CLEANED SURFACE AND POWER TOOL CLEANED SURFACE - Utility Air of Service Temperature up to 60 C COATING SYSTEM NO.19B (ALTERNATIVE) For Internal Application : INITIAL PAINTING, MAINTENANCE PAINTING FOR BLAST CLEANED SURFACE AND POWER TOOL CLEANED SURFACE Utility Air of Service Temperature up to 60 C COATING SYSTEM NO.19C For Internal Application : INITIAL PAINTING , MAINTENANCE PAINTING FOR BLAST CLEANED SURFACE AND POWER TOOL CLEANED SURFACE - Utility Air of Service Temperature more than 60 C COATING SYSTEM NO.21A For Internal Application : INITIAL PAINTING, MAINTENANCE PAINTING FOR BLAST CLEANED SURFACE AND POWER TOOL CLEANED SURFACE - Methanol Percroethalyne of Service Temperature up to 60 C COATING SYSTEM NO.21B (Alternative) For Internal Application : INITIAL PAINTING, MAINTENANCE PAINTING FOR BLAST CLEANED SURFACE AND POWER TOOL CLEANED SURFACE (Alternative) Methanol Percroethalyne of Service Temperature up to 60 C COATING SYSTEM NO.22A For Internal Application : INITIAL PAINTING, MAINTENANCE PAINTING FOR BLAST CLEANED SURFACE AND POWER TOOL CLEANED SURFACE - Triethylene Glycol / Methylethylene Glycol of Service Temperature Up to 60 Environment Notes A high performance coating specification for exposure in immersed environments. The specification provided is based on a maximum operating temperature of 50 C. Coatings for immersed conditions require special consideration and you must contact International for detailed advice on preparation , application and cure prior to their use. A high performance coating specification for exposure in immersed environments. The specification provided is based on a maximum operating temperature of 50 C. Coatings for immersed conditions require special consideration and you must contact International for detailed advice on preparation , application and cure prior to their use. A high performance coating specification for exposure in immersed environments. The specification provided is based on a maximum operating temperature of 50 C. Coatings for immersed conditions require special consideration and you must contact International for detailed advice on preparation , application and cure prior to their use. A high performance coating specification for exposure in immersed environments. The specification provided is based on a maximum operating temperature of 50 C. Coatings for immersed conditions require special consideration and you must contact International for detailed advice on preparation , application and cure prior to their use. A high performance coating specification for exposure in immersed environments. The specification provided is based on a maximum operating temperature of 50 C. Coatings for immersed conditions require special consideration and you must contact International for detailed advice on preparation , application and cure prior to their use. A high performance coating specification for exposure in immersed environments. The specification provided is based on a maximum operating temperature of 50 C. Coatings for immersed conditions require special consideration and you must contact International for detailed advice on preparation , application and cure prior to their use. A high performance coating specification for exposure in immersed environments. The specification provided is based on a maximum operating temperature of 50 C. Coatings for immersed conditions require special consideration and you must contact International for detailed advice on preparation , application and cure prior to their use. A high performance coating specification for exposure in immersed environments. The specification provided is based on a maximum operating temperature of 50 C. Coatings for immersed conditions require special consideration and you must contact International for detailed advice on preparation , application and cure prior to their use. A high performance coating specification for exposure in immersed environments. The specification provided is based on a maximum operating temperature of 50 C. Coatings for immersed conditions require special consideration and you must contact International for detailed advice on preparation , application and cure prior to their use. A high performance coating specification for exposure in immersed environments. The specification provided is based on a maximum operating temperature of 50 C. Coatings for immersed conditions require special consideration and you must contact International for detailed advice on preparation ,
PAINTING SPECIFICATION
18/07/2006 Page 6
Summary
Area Description COATING SYSTEM NO.22B (Alternative) For Internal Application : INITIAL PAINTING, MAINTENANCE PAINTING FOR BLAST CLEANED SURFACE AND POWER TOOL CLEANED SURFACE (Alternative) Triethylene Glycol / Methylethylene Glycol of Service Temperature Up to 60 C Environment Notes A high performance coating specification for exposure in immersed environments. The specification provided is based on a maximum operating temperature of 50 C. Coatings for immersed conditions require special consideration and you must contact International for detailed advice on preparation , application and cure prior to their use.
PAINTING SPECIFICATION
18/07/2006 Page 7
COATING SYSTEM NO.1A For External Application : INITIAL PAINTING - Carbon Steel Design Temperature < 110C NON INSULATED in The Atmospheric Zone
A low durability (upto 5 years) coating specification designed for environments classified by ISO 12944-2 as C5-I very high corrosivity (Industrial).
Polyurethane
50 275
3 Hr - Ext
11.40
PAINTING SPECIFICATION
18/07/2006 Page 8
COATING SYSTEM NO.1B For External Application : MAINTENANCE PAINTING FOR BLAST CLEANED SURFACE - Carbon Steel Design Temperature < 110C NON INSULATED In the Atmospheric Zone
This specification is intended for Maintenance and Repair.
Polyurethane
Airless Spray, Brush, Color Conventional Spray, Range Roller, Air Spray
57
50 275
3 Hr - Ext
11.40
PAINTING SPECIFICATION
18/07/2006 Page 9
COATING SYSTEM NO.1C For External Application : MAINTENANCE PAINTING FOR POWER TOOL CLEANED SURFACE - Carbon Steel Design Temperature < 110C NON INSULATED in the Atmospheric Zone
This specification is intended for Maintenance and Repair.
PAINTING SPECIFICATION
18/07/2006 Page 10
COATING SYSTEM NO.2A For External Application : INITIAL PAINTING - Carbon Steel Design Temperature < 110C INSULATED in the Atmospheric Zone
A low durability (upto 5 years) coating specification designed for environments classified by ISO 12944-2 as C5-I very high corrosivity (Industrial).
Greenish Airless Spray, Air Grey Spray Airless Spray, Beige Brush, Roller, Air Spray
PAINTING SPECIFICATION
18/07/2006 Page 11
COATING SYSTEM NO.2B For External Application : MAINTENANCE PAINTING FOR BLAST CLEANED SURFACE - Carbon Steel Design Temperature < 110C INSULATED in the Atmospheric Zone
This specification is intended for Maintenance and Repair.
PAINTING SPECIFICATION
18/07/2006 Page 12
COATING SYSTEM NO.2C For External Application : MAINTENANCE PAINTING FOR POWER TOOL CLEANED SURFACE - Carbon Steel Design Temperature < 110C INSULATED in the Atmospheric Zone
This specification is intended for Maintenance and Repair.
Surface Interseal Tolerant Epoxy 670HS Surface Interseal Tolerant Epoxy 670HS
Grey
82
125 250
4 Hr - 2 Wk
6.56
This specification complies with our environmental Ecotech Initiative to limit organic solvent emissions and certain potentially harmful substances such as isocyanates. For further information on Ecotech please contact International.
PAINTING SPECIFICATION
18/07/2006 Page 13
COATING SYSTEM NO.3A For External Application : INITIAL PAINTING AND MAINTENANCE PAINTING - Offshore Platform Decks (including primary and secondary structures)
A low durability (upto 5 years) coating specification designed for environments classified by ISO 12944-2 as C5-I very high corrosivity (Industrial).
PAINTING SPECIFICATION
18/07/2006 Page 14
COATING SYSTEM NO.3B For External Application : INITIAL PAINTING AND MAINTENANCE PAINTING (Alternative) - Offshore Platform Decks (including primary and secondary structures)
A low durability (upto 5 years) coating specification designed for environments classified by ISO 12944-2 as C5-I very high corrosivity (Industrial).
Airless Spray, Gloaming Brush, Roller, Air Spray Airless Spray, Black Brush, Roller, Air Spray
90
400 800
5 Hr - 2 D
2.25
This specification complies with our environmental Ecotech Initiative to limit organic solvent emissions and certain potentially harmful substances such as isocyanates. For further information on Ecotech please contact International.
PAINTING SPECIFICATION
18/07/2006 Page 15
COATING SYSTEM NO.4A For External Application : INITIAL PAINTING AND MAINTENANCE PAINTING - Splash Zone and Spray Zone
A low durability (upto 5 years) coating specification designed for environments classified by ISO 12944-2 as C5-I very high corrosivity (Industrial).
PAINTING SPECIFICATION
18/07/2006 Page 16
COATING SYSTEM NO.4B (ALTERNATIVE) For External Application : INITIAL PAINTING AND MAINTENANCE PAINTING - Splash Zone and Spray Zone
A low durability (upto 5 years) coating specification designed for environments classified by ISO 12944-2 as C5-I very high corrosivity (Industrial).
Airless Spray, Gloaming Brush, Roller, Air Spray Airless Spray, Black Brush, Roller, Air Spray
90
500 1000
5 Hr - 2 D
1.80
This specification complies with our environmental Ecotech Initiative to limit organic solvent emissions and certain potentially harmful substances such as isocyanates. For further information on Ecotech please contact International.
PAINTING SPECIFICATION
18/07/2006 Page 17
COATING SYSTEM NO.5A(1) For External Application : INITIAL PAINTING & MAINTENANCE PAINTING - Carbon Steel Design Facilities with Surface Temperature 110 - 250C (INSULATED AND NON INSULATED) in the Atmospheric Zone
This specification is designed for areas exposed to elevated temperatures.
Greenish Airless Spray, Grey Air Spray Brush, Roller, White Air Spray Brush, Roller, Grey Air Spray
PAINTING SPECIFICATION
18/07/2006 Page 18
COATING SYSTEM NO.5A(2) For External Application : INITIAL PAINTING & MAINTENANCE PAINTING - Carbon Steel Design Facilities with Surface Temperature 250 - 450 deg C (INSULATED AND NON INSULATED) in the Atmospheric Zone
This specification is designed for areas exposed to elevated temperatures.
Greenish Airless Spray, Grey Air Spray Aluminium Brush, Roller, Air Spray Brush, Roller, Air Spray
Aluminium
45
25 125
6 Hr - Ext
18.00
PAINTING SPECIFICATION
18/07/2006 Page 19
COATING SYSTEM NO.5B(1) For External Application : MAINTENANCE PAINTING FOR POWER TOOL CLEANED SURFACE - Carbon Steel Design Facilities with Surface Temperature 110 - 250 C (INSULATED AND NON INSULATED) in the Atmospheric Zone
This specification is intended for Maintenance and Repair.
Intertherm 890 High Temperature Intertherm Silicone Acrylic 875 High Temperature Intertherm Silicone Acrylic 875
PAINTING SPECIFICATION
18/07/2006 Page 20
COATING SYSTEM NO.5B(2) For External Application : MAINTENANCE PAINTING FOR POWER TOOL CLEANED SURFACE - Carbon Steel Design Facilities with Surface Temperature 250 - 450 C (INSULATED AND NON INSULATED) in the Atmospheric Zone
This specification is intended for Maintenance and Repair.
Aluminium
45
25 90
6 Hr - Ext
18.00
Intertherm 890 may require thinning to achieve a DFT of 40 microns. NOTE : 1. The maximum heat resistance for Intertherm 50 is 540 degree C.
PAINTING SPECIFICATION
18/07/2006 Page 21
COATING SYSTEM NO.6A For External Application : INITIAL PAINTING - GALVANISED STEEL
A high performance coating specification designed for application over non-ferrous metals
PAINTING SPECIFICATION
18/07/2006 Page 22
COATING SYSTEM NO.7A(1) For External Application : INITIAL PAINTING & MAINTENANCE PAINTING - Stainless Steel (NON INSULATED) facilities Operating < 110C
This specification is designed to be used over Stainless Steel
PAINTING SPECIFICATION
18/07/2006 Page 23
COATING SYSTEM NO.7A(2) For External Application : INITIAL PAINTING & MAINTENANCE PAINTING - Stainless Steel (INSULATED) facilities Operating < 110C
This specification is designed to be used over Stainless Steel
PAINTING SPECIFICATION
18/07/2006 Page 24
COATING SYSTEM NO.7A(3) For External Application : INITIAL PAINTING & MAINTENANCE PAINTING - Stainless Steel (INSULATED AND NON INSULATED) facilities Operating 110 540 C
This specification is designed to be used over Stainless Steel
Aluminium
45
25 50
6 Hr - Ext
18.00
PAINTING SPECIFICATION
18/07/2006 Page 25
COATING SYSTEM NO.8A For External Application : INITIAL PAINTING - Carbon Steel Storage Tank
The specification given is our nearest product match for the system based on information received. Without further details of environment and conditions of service we cannot be certain that the system specified will give the best performance and therefore do not accept any liability for the performance of the product or loss or damage (other than death or personal injury resulting from our negligence) arising out of use of the product.
Surface Interseal Tolerant Epoxy 670HS Surface Interseal Tolerant Epoxy 670HS
Airless Spray, Aluminium Brush, Roller, Air Spray Airless Spray, Brush, Roller, Air Grey Spray
82
200 400
4 Hr - 2 Wk
4.10
This specification complies with our environmental Ecotech Initiative to limit organic solvent emissions and certain potentially harmful substances such as isocyanates. For further information on Ecotech please contact International. Please be informed that International Paint will cease manufacture of Tar containing products from the 1st of March 2005. The main reason for concern however is that products containing coal tar, coal tar pitches, tar acids, petroleum tar and petroleum tar pitches are all potential carcinogens (cancer causing). Therefore, we propose an alternative system as above.
PAINTING SPECIFICATION
18/07/2006 Page 26
COATING SYSTEM NO.8B For External Application : INITIAL AND MAINTENANCE PAINTING - Carbon Steel Storage Tank - Underside of Bottom plate (ONLY if painting is required for corrosion protection to supplement cathodic protection)
The specification given is our nearest product match for the system based on information received. Without further details of environment and conditions of service we cannot be certain that the system specified will give the best performance and therefore do not accept any liability for the performance of the product or loss or damage (other than death or personal injury resulting from our negligence) arising out of use of the product.
Surface Interseal Tolerant Epoxy 670HS Surface Interseal Tolerant Epoxy 670HS
Airless Spray, Aluminium Brush, Roller, Air Spray Airless Spray, Brush, Roller, Air Grey Spray
82
200 400
4 Hr - 2 Wk
4.10
This specification complies with our environmental Ecotech Initiative to limit organic solvent emissions and certain potentially harmful substances such as isocyanates. For further information on Ecotech please contact International.
PAINTING SPECIFICATION
18/07/2006 Page 27
COATING SYSTEM NO.8C For External Application : Carbon Steel Storage Tank - Shell, Roof Plate, Stairways, Stair Treads, Gangways And Others External parts include the piping (NON GALVANISED)
The specification given is our nearest product match for the system based on information received. Without further details of environment and conditions of service we cannot be certain that the system specified will give the best performance and therefore do not accept any liability for the performance of the product or loss or damage (other than death or personal injury resulting from our negligence) arising out of use of the product.
Polyurethane
Airless Spray, Brush, Color Conventional Spray, Range Roller, Air Spray
57
50 275
3 Hr - Ext
11.40
PAINTING SPECIFICATION
18/07/2006 Page 28
COATING SYSTEM NO.9A For External Application : INITIAL AND MAINTENANCE PAINTING - Timber Decks
A high performance coating specification for application on timbers.
Airless Spray, Brush, Aluminium Conventional Spray, Wood Roller Color Airless Spray, Brush, Range Roller, Air Spray Color Airless Spray, Brush, Range Roller, Air Spray
PAINTING SPECIFICATION
18/07/2006 Page 29
PAINTING SPECIFICATION
18/07/2006 Page 30
COATING SYSTEM NO.11 For External Application : Timber Decks - Living Quarters, Pressurised Building, Control Room (Interior)
A high performance coating specification for application on timbers.
PAINTING SPECIFICATION
18/07/2006 Page 31
COATING SYSTEM NO.13A For Internal Application : INITIAL PAINTING, MAINTENANCE PAINTING FOR BLAST CLEANED SURFACE AND POWER TOOL CLEANED SURFACE - Fuel Gas (Sweet And Sour) for Service Temperature Up To 60 C
A high performance coating specification for exposure in immersed environments. The specification provided is based on a maximum operating temperature of 50 C. Coatings for immersed conditions require special consideration and you must contact International for detailed advice on preparation , application and cure prior to their use.
PAINTING SPECIFICATION
18/07/2006 Page 32
COATING SYSTEM NO.14A(1) For Internal Application : INITIAL PAINTING, MAINTENANCE PAINTING FOR BLAST CLEANED SURFACE AND POWER TOOL CLEANED SURFACE Roof and Shell Plate Of Service Temperature Up To 60C
A high performance coating specification for exposure in immersed environments. The specification provided is based on a maximum operating temperature of 50 C. Coatings for immersed conditions require special consideration and you must contact International for detailed advice on preparation , application and cure prior to their use.
PAINTING SPECIFICATION
18/07/2006 Page 33
COATING SYSTEM NO.14A(2) For Internal Application : INITIAL PAINTING, MAINTENANCE PAINTING FOR BLAST CLEANED SURFACE AND POWER TOOL CLEANED SURFACE Bottom Plate and Vessels Up To 60C
A high performance coating specification for exposure in immersed environments. The specification provided is based on a maximum operating temperature of 50 C. Coatings for immersed conditions require special consideration and you must contact International for detailed advice on preparation , application and cure prior to their use.
PAINTING SPECIFICATION
18/07/2006 Page 34
COATING SYSTEM NO.14A(3) (Alternative) For Internal Application : INITIAL PAINTING, MAINTENANCE PAINTING FOR BLAST CLEANED SURFACE AND POWER TOOL CLEANED SURFACE - Bottom Plate Of Service Temperature Up To 60 C
A high performance coating specification for exposure in immersed environments. The specification provided is based on a maximum operating temperature of 50 C. Coatings for immersed conditions require special consideration and you must contact International for detailed advice on preparation , application and cure prior to their use.
Airless Spray, Interline 982 Primrose Brush, Roller, Air Spray Airless Spray, Interzone Black Brush, Roller, Air 505 tropical Spray
90
400 425
5 Hr - 2 D
2.25
PAINTING SPECIFICATION
18/07/2006 Page 35
COATING SYSTEM NO.15A For Internal Application : INITIAL PAINTING, MAINTENANCE PAINTING FOR BLAST CLEANED SURFACE AND POWER TOOL CLEANED SURFACE Naptha, Reformate, Jet A Fuel, Lube Oil, Fuel Oil, Gasoline (Leaded & Unleaded) For Service Temp. Up to 60
A high performance coating specification for exposure in immersed environments. The specification provided is based on a maximum operating temperature of 50 C. Coatings for immersed conditions require special consideration and you must contact International for detailed advice on preparation , application and cure prior to their use.
PAINTING SPECIFICATION
18/07/2006 Page 36
COATING SYSTEM NO.16A For Internal Application : INITIAL PAIINTING, MAINTENANCE PAINTING FOR BLAST CLEANED SURFACE AND POWER TOOL CLEANED SURFACE Diesel (Roof and Shell Plate) of Service Temperature Up to 60 C
A high performance coating specification for exposure in immersed environments. The specification provided is based on a maximum operating temperature of 50 C. Coatings for immersed conditions require special consideration and you must contact International for detailed advice on preparation , application and cure prior to their use.
PAINTING SPECIFICATION
18/07/2006 Page 37
COATING SYSTEM NO.16B For Internal Application : INITIAL PAIINTING, MAINTENANCE PAINTING FOR BLAST CLEANED SURFACE AND POWER TOOL CLEANED SURFACE Diesel (Bottom Plate and Vessels) of Service Temperature Up to 60C
A high performance coating specification for exposure in immersed environments. The specification provided is based on a maximum operating temperature of 50 C. Coatings for immersed conditions require special consideration and you must contact International for detailed advice on preparation , application and cure prior to their use.
PAINTING SPECIFICATION
18/07/2006 Page 38
COATING SYSTEM NO.16C (ALTERNATIVE) For Internal Application : INITIAL PAIINTING, MAINTENANCE PAINTING FOR BLAST CLEANED SURFACE AND POWER TOOL CLEANED SURFACE - Diesel (Bottom Plate and Vessels) of Service Temperature Up to 60C
A high performance coating specification for exposure in immersed environments. The specification provided is based on a maximum operating temperature of 50 C. Coatings for immersed conditions require special consideration and you must contact International for detailed advice on preparation , application and cure prior to their use.
Airless Spray, Primrose Brush, Roller, Air Spray Airless Spray, Brush, Roller, Air Black Spray
90
400 440
5 Hr - 2 D
2.25
NOTE : 1. Surface Preparation : Blast cleaning to ISO8501-1:1988, Sa2.5, or Power Tool cleaning to ISO8501-1:1988, St3 for minor touch-up painting.
PAINTING SPECIFICATION
18/07/2006 Page 39
COATING SYSTEM NO.17A For Internal Application : INITIAL PAINTING, MAINTENANCE PAINTING FOR BLAST CLEANED SURFACE AND POWER TOOL CLEANED SURFACE - Sea Water, Produced Water, Brackish, Demineralised Water, Brine of Service Temperature up to 60 C
A high performance coating specification for exposure in immersed environments. The specification provided is based on a maximum operating temperature of 50 C. Coatings for immersed conditions require special consideration and you must contact International for detailed advice on preparation , application and cure prior to their use.
PAINTING SPECIFICATION
18/07/2006 Page 40
COATING SYSTEM NO.18A For Internal Application : INITIAL PAINTING, MAINTENANCE PAINTING FOR BLAST CLEANED SURFACE AND POWER TOOL CLEANED SURFACE Steam (Condensate), Boiler Feed of Service Temperature up to 100C
A high performance coating specification for exposure in immersed environments. The specification provided is based on a maximum operating temperature of 50 C. Coatings for immersed conditions require special consideration and you must contact International for detailed advice on preparation , application and cure prior to their use.
PAINTING SPECIFICATION
18/07/2006 Page 41
COATING SYSTEM NO.19A For Internal Application : INITIAL PAINTING, MAINTENANCE PAINTING FOR BLAST CLEANED SURFACE AND POWER TOOL CLEANED SURFACE Utility Air of Service Temperature up to 60C
A high performance coating specification for exposure in immersed environments. The specification provided is based on a maximum operating temperature of 50 C. Coatings for immersed conditions require special consideration and you must contact International for detailed advice on preparation , application and cure prior to their use.
PAINTING SPECIFICATION
18/07/2006 Page 42
COATING SYSTEM NO.19B (ALTERNATIVE) For Internal Application : INITIAL PAINTING, MAINTENANCE PAINTING FOR BLAST CLEANED SURFACE AND POWER TOOL CLEANED SURFACE - Utility Air of Service Temperature up to 60 C
A high performance coating specification for exposure in immersed environments. The specification provided is based on a maximum operating temperature of 50 C. Coatings for immersed conditions require special consideration and you must contact International for detailed advice on preparation , application and cure prior to their use.
PAINTING SPECIFICATION
18/07/2006 Page 43
COATING SYSTEM NO.19C For Internal Application : INITIAL PAINTING , MAINTENANCE PAINTING FOR BLAST CLEANED SURFACE AND POWER TOOL CLEANED SURFACE Utility Air of Service Temperature more than 60C
A high performance coating specification for exposure in immersed environments. The specification provided is based on a maximum operating temperature of 50 C. Coatings for immersed conditions require special consideration and you must contact International for detailed advice on preparation , application and cure prior to their use.
PAINTING SPECIFICATION
18/07/2006 Page 44
COATING SYSTEM NO.21A For Internal Application : INITIAL PAINTING, MAINTENANCE PAINTING FOR BLAST CLEANED SURFACE AND POWER TOOL CLEANED SURFACE Methanol Percroethalyne of Service Temperature up to 60C
A high performance coating specification for exposure in immersed environments. The specification provided is based on a maximum operating temperature of 50 C. Coatings for immersed conditions require special consideration and you must contact International for detailed advice on preparation , application and cure prior to their use.
PAINTING SPECIFICATION
18/07/2006 Page 45
COATING SYSTEM NO.21B (Alternative) For Internal Application : INITIAL PAINTING, MAINTENANCE PAINTING FOR BLAST CLEANED SURFACE AND POWER TOOL CLEANED SURFACE (Alternative) - Methanol Percroethalyne of Service Temperature up to 60 C
A high performance coating specification for exposure in immersed environments. The specification provided is based on a maximum operating temperature of 50 C. Coatings for immersed conditions require special consideration and you must contact International for detailed advice on preparation , application and cure prior to their use.
PAINTING SPECIFICATION
18/07/2006 Page 46
COATING SYSTEM NO.22A For Internal Application : INITIAL PAINTING, MAINTENANCE PAINTING FOR BLAST CLEANED SURFACE AND POWER TOOL CLEANED SURFACE Triethylene Glycol / Methylethylene Glycol of Service Temperature Up to 60C
A high performance coating specification for exposure in immersed environments. The specification provided is based on a maximum operating temperature of 50 C. Coatings for immersed conditions require special consideration and you must contact International for detailed advice on preparation , application and cure prior to their use.
PAINTING SPECIFICATION
18/07/2006 Page 47
COATING SYSTEM NO.22B (Alternative) For Internal Application : INITIAL PAINTING, MAINTENANCE PAINTING FOR BLAST CLEANED SURFACE AND POWER TOOL CLEANED SURFACE (Alternative) - Triethylene Glycol / Methylethylene Glycol of Service Temperature Up to 60C
A high performance coating specification for exposure in immersed environments. The specification provided is based on a maximum operating temperature of 50 C. Coatings for immersed conditions require special consideration and you must contact International for detailed advice on preparation , application and cure prior to their use.
PAINTING SPECIFICATION
18/07/2006 Page 48
Product List
Product Name Intergard 475HS tropical Interlac 665 Interline 399 Interline 399 Interline 850 Interline 850 Interline 982 International GTA004 International GTA007 International GTA220 International GTA733 International GTA803 Interprime 321 Interseal 670HS Interseal 670HS Interthane 990 Intertherm 50 Intertherm 875 Intertherm 875 Intertherm 890 Interzinc 22 Colour Group Reference Beige Color Range Grey White Grey White Primrose A A A A A Aluminium Wood Aluminium Grey Color Range Aluminium EVA531/A (20L PACK SIZE) EX-STOCK CL SERIES (5L PACK SIZE) MADE-TO-ORDER STOCK TLA393/A (20L PACK SIZE) MADE-TO-ORDER STOCK - Minimum Qty Required TLA390/A (20L PACK SIZE) MADE-TO-ORDER STOCK - Minimum Quantity Required TLA851/A (20L PACK SIZE) EX-STOCK TLA850/A (20L PACK SIZE) EX-STOCK TPA018/A (5L PACK SIZE) MADE-TO-ORDER STOCK - Minimum Quantity Required GTA004 (20L PACK SIZE) EX-STOCK GTA007 (20L PACK SIZE) EX-STOCK GTA220 (20L PACK SIZE) EX-STOCK GTA733 (20L PACK SIZE) EX-STOCK GTA803 (20L PACK SIZE) EX-STOCK CWA021 (5L PACK SIZE) MADE-TO-ORDER STOCK
EGA230/A (5L PACK SIZE) MADE-TO-ORDER STOCK EGA236/A (20L PACK SIZE) EX-STOCK PH SERIES/A (5L PACK SIZE) MADE-TO-ORDER STOCK HTA097 (5L PACK SIZE) EX-STOCK HAK766 (5L PACK SIZE) MADE-TO-ORDER STOCK - Minimum Quantity Grey Required HAB000 (5L PACK SIZE) MADE-TO-ORDER STOCK - Minimum Quantity White Required HTA290/A (5L PACK SIZE) MADE-TO-ORDER STOCK - Minimum Quantity Dark Grey Required Greenish Grey QHA028/A (5L PACK SIZE) EX-STOCK
PAINTING SPECIFICATION
18/07/2006 Page 49
Product List
Product Name Interzinc 52 Interzone 2000 Malaysia Interzone 2000 Malaysia Interzone 505 tropical Interzone 505 tropical Colour Group Grey Black Grey Black Gloaming Reference EPA142/A (5L PACK SIZE) EX-STOCK HGA329/A (10L PACK SIZE) MADE-TO-ORDER STOCK - Minimum Quantity Required HGA637/A (10L PACK SIZE) MADE-TO-ORDER STOCK - Minimum Quantity Required EGA879/A (20L PACK SIZE) MADE-TO-ORDER STOCK - Minimum Quantity Required EGT000/A (20L PACK SIZE) MADE-TO-ORDER STOCK - Minimum Quantity Required