RIG/PLANT
REFERENCE
REFERENCE DESCRIPTION
SSGD
ADDITIONAL CODE REMARKS MAIN TAG NUMBER CLIENT PO NUMBER DISCIPLINE SDRL CODE TOTAL PGS
6.2
This document contains proprietary and confidential information which belongs to National Oilwell Varco; it is loaned for limited purposes only and remains the property of National Oilwell Varco. Reproduction, in whole or in part; or use of this design or distribution of this information to others is not permitted without the express written consent of National Oilwell Varco. This document is to be returned to National Oilwell Varco upon request and in any event upon completion of the use for which it was loaned. Copyright National Oilwell Varco - 2008 DOCUMENT NUMBER
REV
03071106
04
www.nov.com
03071106 04 2 of 9
REVISION HISTORY
04 03 02 01
Rev
TTL EM EM
Prepared
EM
EM
Checked
Approved
CHANGE DESCRIPTION
Revision 04 03 Change description Updated according to new template for SSGD data sheets Changed drum diameter to 52" (as BP Clair) and drum length to 72" (as BP Clair). Updated performance charts. Updated technical section. Updated performance table. Updated paint spec. Updated power consumption section Added hoisting capacity @10 lines in model number. First Issue
02
01
www.nov.com
03071106 04 3 of 9
TABLE OF CONTENTS 1 PERFORMANCE .............................................................................................................. 4 1.1 1.2 1.3 1.4 2 Hoisting capacity summary ..................................................................................... 4 Performance @ 10 lines ......................................................................................... 5 Performance @ 12 lines ......................................................................................... 6 Performance @ 14 lines ......................................................................................... 7
www.nov.com
03071106 04 4 of 9
PERFORMANCE
1.1
Hoisting capacity summary DRILLING PERFORMANCE Short tons Maximum load @ 10 lines 470 Maximum load @ 12 lines 550 Maximum load @ 14 lines 650 Max. Continuous Power 3450 HP Max. Intermittent Power 4830 HP
For hook load versus speed, see the attached curves. The Drawworks is designed for hook loads as specified above and is also designed for overload up to 140% for braking/acceleration purposes and for heavy load conditions. Limits are included in the Drawworks PLC to prevent that the maximum load on the Drawworks is exceeded.
NOTE: All load calculations are done with the GEB 22 AC motor. Curves are calculated based on 1 wire diameter. Maximum motor speed is 2300 rpm.
www.nov.com
03071106 04 5 of 9
1.2
Performance @ 10 lines
1
Continuous hold means the static hook load calculated without any friction factors, ie. No movement of the drum or hook.
www.nov.com
03071106 04 6 of 9
1.3
Performance @ 12 lines
www.nov.com
03071106 04 7 of 9
1.4
Performance @ 14 lines
www.nov.com
03071106 04 8 of 9
2
1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. 13. 14. 15. 16. 17. 18. 19. 20. 21. 22. 23. 24. 25. 26. 27. 28. 29. 30. 31. 32. 33. 34. 35. 36. 37. 38. 39.
2 3
TECHNICAL SPECIFICATION
Service Design code / standard 3.d party verification Area classification Design Temperature (other ranges optional) Drum diameter (root of grooving) Drum length (including wear plates) Drill line diameter Maximum block travel @ 10 lines (3 layers, 10 dead wraps) Maximum block travel @ 12 lines (3 layers, 10 dead wraps) Maximum block travel @ 14 lines (3 layers, 10 dead wraps) Gear Ratio Brake system Main Brake System Park & Emergency No of Brake Discs No of Brake Calipers Brake Disc Cooling DESIGN DATA Drilling API 7K, ANSI B31.3, AWSD1.1, AISC 9th edition. NA/DNV/LOYDS/ABS Zone 1 (Zone 2 for ATEX certified system) 14 104 F - 10 - + 40 C 52 1321 mm 82 2083 mm 1 5/8 NA 205 ft 62.5 m 170 ft 146 ft 52 m 44.7 m
1:10.5 AC-motors Disc brakes 2 6 Air Cooling WEIGHTS Weight of assembled Drawworks (dry weight)2 123000 lbs Weight motor (GEB22A) 6300 lbs UTILITY REQUIREMENTS Lube Oil Heat exchanger cooling fresh water flow 20 GPM @ 96.8F (air cooled heat exchanger optional) Lube oil flow NA (self contained) Hydraulic flow NA (self contained) Air supply NA (not required) POWER REQUIREMENTS34 AC drilling motor See section Drilling Motor Motor heater for AC Drilling motor 230 V, 60 Hz, 1 phase Motor for lube oil pump (2 ea) 480 V, 60 Hz, 3 phases Motor for lube oil cooling fan (1 ea) (optional) 480 V, 60 Hz, 3 phases Motor for hydraulic oil pump (2 ea) 480 V, 60 Hz, 3 phases PLC cabinet 230 V, 60 Hz, 1 phase, Light fixtures (2 ea) 110-254V, 60 Hz, 1 phase DRILLING MOTOR Type (refer to quotation for quoted type) General Electric GEB22A Quantity 3 ea. Output horsepower continuous (each) 1150 HP 858 kW Rated current 1120 Amps Voltage (converter supply) 600 - 690 V Classification for use in hazardous area Eex e IIB Ingress Protection motor IP44 Ingress Protection motor junction box IP56 Motor encoder HTL 1024 PPM
Baylor CM628TUT 3 ea 1350 HP 1007 kW 1180 Amps 600 - 690 V EEx e II T3 IP45 IP56 HTL 1024 PPM
Includes motors. Power requirement might vary slightly depending of brand selected on each project. 4 Other voltages can be supplied on request. Typically 110V, 440 V, 690 V www.nov.com
03071106 04 9 of 9
40.
Utra Grip Reinforced Inorganic Zinc Primer: min 2-3 mils DFT EP-62 Hi Build Epoxy Primer min 5-7 mils DFT EX-2C Iso Free Modified Acrylic Epoxy: min 2-3 mils DFT 9-13 mils DFT
41.
External Colour: RAL 5005 Blue Internal Colour: RAL 9010 White DRAWING REFERENCES General Arrangement SSGD Drawworks (typical) SSGD-9130B028 MOTOR COOLING SYSTEM BLOWER SKID Type: Nyborg 3-6772 Quantity 1 ea Configuration 2 ea redundant blowers duty / stand-by system Blower motors rating (2 ea) 480 V, 60 Hz, 1 phase, 57.7 HP 43 kW Blower Motor heater (2 ea) 230 V, 60 Hz, 1 phase, 0.14 HP 104 W Classification for use in hazardous area Safe area installation Ingress Protection IP55 (IP56 on request) Speed 1770 rpm Coating Hot dip galvanized Weight 5953 lbs 2700 kg DRAWING REFERENCES General Arrangement 69947539 DRAWWORKS CONTROL SYSTEM Classification for use in hazardous area Safe area Environment Dry, air conditioned Cabinet type Rittal TS8 Ingress protection IP22 PLC type Siemens S7 300 series DRAWING REFERENCES General Arrangement SSGD-GAD-800-01 PACKING / CRATING Packed/Boxed and preserved, ready for transportation at: Location Drawworks: Workshop Edmonton Canada Location Controls: Workshop Stavanger Norway Location Blower skid: Workshop Malbork Poland Lifting gear/frame not included GENERAL ATEX CE
42. 43. 44. 45. 46. 47. 48. 49. 50. 51. 52.
59.
60.
Special certification
www.nov.com