FISHER-ROSEMOUNT SYSTEMS Course 7009 -- Rev 3 - 4/15/01 The Simulated Process
Objectives
Upon completion of this module you will be able to: Define the process to be controlled Define the characteristics of the various plant areas Define the characteristics of the Device Signal Tags (DSTs) Perform a total download View diagnostics
2-3
FISHER-ROSEMOUNT SYSTEMS Course 7009 -- Rev 3 - 4/15/01 The Simulated Process
PLANT_AREA_A
Tank101
LEVEL-101 SFC-T101
LI-101
XVSTAT-101 To Tank201
2-4
FISHER-ROSEMOUNT SYSTEMS Course 7009 -- Rev 3 - 4/15/01 The Simulated Process
2-5
FISHER-ROSEMOUNT SYSTEMS Course 7009 -- Rev 3 - 4/15/01 The Simulated Process
PLANT_AREA_B
Tank201
From Tank101
PLM-SHUTDOWN
LEV2-SIM
LIC-20X
FIC-20X MTR-203
=
2-6
FISHER-ROSEMOUNT SYSTEMS Course 7009 -- Rev 3 - 4/15/01 The Simulated Process
2-7
FISHER-ROSEMOUNT SYSTEMS Course 7009 -- Rev 3 - 4/15/01 The Simulated Process
2-8
FISHER-ROSEMOUNT SYSTEMS Course 7009 -- Rev 3 - 4/15/01 The Simulated Process
Plant Areas
Listed below are the characteristics of a Plant Area. Contain control modules Define user privilege boundaries Define workstation alarms boundaries Workstation 1 Workstation 2
User 1
User 2
Area A
FIC-101 LIC-101 XV-101 MTR-101
Area B
FIC-201 LIC-201 XV-201 MTR-201
Area C
FIC-301 LIC-301 XV-301 MTR-301
2-9
FISHER-ROSEMOUNT SYSTEMS Course 7009 -- Rev 3 - 4/15/01 The Simulated Process
Equipment Hierarchy
DeltaV supports a logical hierarchy for large systems which includes the following levels: Area - logical division of a process control system. Areas typically represent plant locations or main processing functions. Cell - may be class-based (available to the Batch Executive) or non class-based. The process cell can be used to organize units and modules within the plant area. Unit - adding control modules to a unit module allows you to take advantage of advanced alarming techniques. Module - links algorithms, displays, I/O, conditions and other characters (parameters) to the equipment. Modules can reside under any level of the hierarchy. Important: DeltaV batch requires a full hierarchy of area, cell, unit in order to operate properly.
2-10
FISHER-ROSEMOUNT SYSTEMS Course 7009 -- Rev 3 - 4/15/01 The Simulated Process
Equipment Hierarchy
Areas Building A
Raw Materials
Tank A Tank B Tank C
Process Cells
Building B
Raw Materials
Tank A Tank B Tank C
Processing
Line A Line B
Processing
Line A Line B
Storage
Tank A Tank B Tank C
Units
Storage
Tank A Tank B Tank C
2-11
FISHER-ROSEMOUNT SYSTEMS Course 7009 -- Rev 3 - 4/15/01 The Simulated Process
Card 1
CH1 FT-1
2
CH1 FY-1
AI AO
FT-1
FY-1
2-12
FISHER-ROSEMOUNT SYSTEMS Course 7009 -- Rev 3 - 4/15/01 The Simulated Process
2-13
FISHER-ROSEMOUNT SYSTEMS Course 7009 -- Rev 3 - 4/15/01 The Simulated Process
2-14
FISHER-ROSEMOUNT SYSTEMS Course 7009 -- Rev 3 - 4/15/01 The Simulated Process
The following workshop requires you to add PLANT_AREA_B. From the DeltaV Explorer select: Control Strategies New Area AREA1 appears as a highlighted selection in the Contents window. Enter the new name PLANT_AREA_B before pressing the ENTER key.
2-15
FISHER-ROSEMOUNT SYSTEMS Course 7009 -- Rev 3 - 4/15/01 The Simulated Process
2-16
FISHER-ROSEMOUNT SYSTEMS Course 7009 -- Rev 3 - 4/15/01 The Simulated Process
2-17
FISHER-ROSEMOUNT SYSTEMS Course 7009 -- Rev 3 - 4/15/01 The Simulated Process
2-18
FISHER-ROSEMOUNT SYSTEMS Course 7009 -- Rev 3 - 4/15/01 The Simulated Process
2-19
FISHER-ROSEMOUNT SYSTEMS Course 7009 -- Rev 3 - 4/15/01 The Simulated Process
Downloads
Download the controller from the DeltaV Explorer by selecting: CTLR Download Controller
2-20
FISHER-ROSEMOUNT SYSTEMS Course 7009 -- Rev 3 - 4/15/01 The Simulated Process
Total/Full Download
Download -- Transfers Controller configuration, setup data and cold restart memory from the configuration database of the Professional Plus to the controller(s) and/or workstation(s) run time database. Downloads are performed from DeltaV Explorer or Control Studio. Two Main Types of Downloads: Total/Full Download -- Downloads the entire configuration for the selected node (controller or workstation). A total/full controller download will download all control modules assigned to the selected node. Control parameters will go to configured default values. This download type is performed from DeltaV Explorer.
Important: It may not be desirable to perform a Total/Full Download on a running process. Partial Download -- Downloads only specific parts of the configuration ie; a single control module. This only affects the control module that is being downloaded. All partial downloads are performed from the DeltaV Explorer or Control Studio.
2-21
FISHER-ROSEMOUNT SYSTEMS Course 7009 -- Rev 3 - 4/15/01 The Simulated Process
2-22
FISHER-ROSEMOUNT SYSTEMS Course 7009 -- Rev 3 - 4/15/01 The Simulated Process
2-23
FISHER-ROSEMOUNT SYSTEMS Course 7009 -- Rev 3 - 4/15/01 The Simulated Process
Download Subsets
Download Subsets Configuration data that is not directly related to a control module. Setup Data includes named sets, parameter security, cold restart information, redundancy information, alarm preferences and event chronicle definitions. Setup data can be downloaded to Controllers and Workstations. Performed from DeltaV Explorer. Changed Setup Data Sends only changed setup data items. Controller Cold Restart Memory Updates the controller non-volatile memory so that the Cold Restart download script is valid. Should be performed after any of the following tasks: Controller Upgrade Decommissioning and re-commissioning Partial download and/or Uploads
This can be performed without affecting working configuration in the controller! Performed from DeltaV Explorer.
2-24
FISHER-ROSEMOUNT SYSTEMS Course 7009 -- Rev 3 - 4/15/01 The Simulated Process
Download Subsets
Re-send Last Known Good Download Sends the last successful total download to a node without going to the database. This is useful for situations where a controller has been replaced. This function enables you to bring the new node up to the previous operational status without downloading recent edits to the configuration. Performed from DeltaV Explorer Update Download Status Updates the download status of the individual Nodes or Network depending on where it is initiated. Performed from DeltaV Explorer.
2-25
FISHER-ROSEMOUNT SYSTEMS Course 7009 -- Rev 3 - 4/15/01 The Simulated Process
2-26
FISHER-ROSEMOUNT SYSTEMS Course 7009 -- Rev 3 - 4/15/01 The Simulated Process
2-27
FISHER-ROSEMOUNT SYSTEMS Course 7009 -- Rev 3 - 4/15/01 The Simulated Process
2-28
FISHER-ROSEMOUNT SYSTEMS Course 7009 -- Rev 3 - 4/15/01 The Simulated Process
Verify the configuration dialog box provides the opportunity to check selected items for unresolved references and other configuration problems before downloading. You will be alerted to problems and given the opportunity to resolve them before continuing with the download. The cautionary note above gives you the opportunity to abort the controllers pending download. Click the Yes button if you wish to continue.
2-29
FISHER-ROSEMOUNT SYSTEMS Course 7009 -- Rev 3 - 4/15/01 The Simulated Process
2-30
FISHER-ROSEMOUNT SYSTEMS Course 7009 -- Rev 3 - 4/15/01 The Simulated Process
2-31
FISHER-ROSEMOUNT SYSTEMS Course 7009 -- Rev 3 - 4/15/01 The Simulated Process
2-32
FISHER-ROSEMOUNT SYSTEMS Course 7009 -- Rev 3 - 4/15/01 The Simulated Process
Workshop - Diagnostics
Launch Diagnostics from the DeltaV Explorer by clicking the Diagnostic button on the toolbar or by selecting Start DeltaV Operator Diagnostics Once Diagnostics has been successfully launched, check out your system.
2-33
FISHER-ROSEMOUNT SYSTEMS Course 7009 -- Rev 3 - 4/15/01 The Simulated Process
2-34
FISHER-ROSEMOUNT SYSTEMS Course 7009 -- Rev 3 - 4/15/01 The Simulated Process